HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 28AGREA,¢R ANCHORAGE AREA BORL. uGH
Department of Environmental Quality
3330 C Street
Anchorage, Alaska 99503
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
J_,/ , 2~
SE,mC TA.K,
DISTANCE /~ J °
FROM WELL ~
INSIDE LENGTH ¢ INSIDE WIDTH
TILE DRAIN FIELD:
DISTANCE FROM WELL ~ FOUNDATION
MANUFACTURER ~._~'~. ,, J~ ~,E MATERIAL
LIQUID DEPTH
NEAREST LOT LINE
!
NUMBER OF LINES / CE BETWEEN LINES
DEPTH OF FILTER
DEPTH: TOP OF TILE TO FINISH GRADE MATERIAL BENEATH TILE
TRENCH WIDTH
NUMBER OF
COMPARTMENTS
LIQUID CAPACITY ?z~'~ GALLONS.
! ?
TOTAL LENGTH
OF LINES
$!
IN. TOTAL EFFECTIVE
IN. ABOVE TILE IN.
DEPTH DISTANCE FROM:
BUILDING NEAREST NEAREST
FOUNDATION LOT LINE , SEWER LINE
SEPTIC SEEPAGE
TANK , SYSTEM
CESSPOOL
· OTHER SOURCES
APPROVED DISAPPROVED
SEWER LINE DEPTH:
PIPE MATERIAL:
LOTSLOPE,
REMARKS:
REMARKS
DIAGRAM OF SYSTEM
DATE~ APPROVED
Form LQ-D32
PERMIT NO.
~Ut~I C I/~"~AL I TY OF Rt~Cl~RRGE
DEPARTMENT t HEALTH AND ENVIRONMENTAL' ,OTECTION
2510 E. TUDOR RD., ANCHORRGE, AK. 99507
276-222~
ON--SITE SENER PERMIT
76260 )
APPLICANT
LOCATION
LEGAL
NEAL KI~6
WAR BDMIRAL
SRB BOX 615 EAGLE RIVER AK
L28A ERGLE RIVER VALLEY RANCH
LOT SIZE
745-~8~4
14000 SQUARE FEET
TYPE OF SOIL RBSORBTION SYSTEM IS: TRENCH
MAXI~IUM NUMBER OF BEDROOMS
SOIL RATING (SQ FT?BR)= liO
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
DEPTH---- :LO LENGTH=::= 28 GRAVEL DEPTH= 6
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAI~IFIELD,
THE DEPTH OF A TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND AND THE BOTTOM OF THE EXCAVATION (IN FEET).
THERE IS NO SET WIDTH FOR TRENCHES.
THE GRAVEL DEPTH IS THE ~IINIMUM DEPTH OF GRAVEL BETWEEN THE OUTFRLL PIPE
AND THE BOTTOM OF THE EXCAVATION (IN FEET).
REQU I RED SEPT I ¢ TANK S I ZE= 1OOO GALLONS
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTION.
MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS
100 FEET FOR R PRIVATE WELL OR 200 FEET FOR A PUBLIC WELL.
SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER
INSTALLATION.
PERffl I t VAL I D FOR Or4E YEAR FROM ISSUE
I CERTIFY THAT
i: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE ~lORE THAN 3 BEDROOMS.
SIGNED:
ISSUED
RPPLICRNT NERL KING
GR£AILi~ Id,i,H~h,/~hk /,k~A UUROUGII;
Department of FnvironmunLal quality
3330 "C" Street
Anchorage, Alaska 99503
SOILS I,O(: - I~F,I~OI.ATION TEST
Performed for ~_.L~.~_~~I ~oFr~ J~d,'5 :_Date Perfonl~d~7~/9?~
Legal Descrip~-i-o-~:/.~'.~. ~ ~ ~o~1~ l~,~ ~o!1~ I~.1~,~
This form reports: Soils,log ~ - Perco~atfon test
10-
Was ground water encountered? ~/o
If yes, at what depth?
Reading Date Gross Tin~ ~let Time
Percol arianrate ..... ~7-mi nu'te.
· Proposed installat-'i~'n?'.See~'~'ge Pit . Drain Field
Depth of Inlet,,,...--.~=- · ~. Depth to bottom of-pit or trench
Depth to Water ~4et Drop
Perfo~ed 8y:~ou~C~d._.~_~.~j?.~._C.~_..Certified By:
E~ %e River Area
GREATER ANCHORAGE AREA BOROUGH
Department of Environmental Quality
3330 "C" Street, Anchorage, Alaska 99503 274-4561
Date Received February 9, 1977
Time of Inspection //;,qf~ ,~,~
Date of Inspection ~'~- 1f').'77 ('~/ZJ~y;~
REQUEST FOR APPROVAL OF ~/~
INDIVIDUAL SEWER & WATER FACILITIES
FOR
Conv.
]. Appr0¥a] 'reguested by: National Bank of Alaska
Mailing Address: Post Office Box 3-3859
Z. Property Owner: Scenic Builders
Mailing Address: % Dave Aquino, 274-2521
3. Legal Description: Lot 28A Eaqle River Valley Ranchettes
4. Location: NHN War Admiral
5. Type of facility to be inspected Single Fa~nily
6. Well Data:
A. Type Community B. Depth
C. Construction~ ~e D. Bacterial Analysis
7. Sewage Disposal system
B. Installer m~/~
A. Installed
C. Septic Tank: 1. Size
D. Seepage Pit: 1. Absorption Area
E. Disposal Field: Total length of lines
Distances:
A. Well to: Septic tank
Nearest lot line
B. Foundation to septic tank
C. Absorption area to nearest lot line
% Ruth
Phone: 279-2506
Phone:
No. of bedrooms 3
2. Manufacturer
Material
, Absorption area
, Other contamination
, Absorption area
, Sewer Lines
EQ-034 (1/74) Page 1 of two pages
-/
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
2510 East Tudor Road, Anchorage, Alaska 99504 276-2221
REQUEST FOR APPROVAL OF
INDIVIDUAL SEWER and WATER FACILITIES
1. Type of Inspectio..~n.'.Z CMRO
2o Pro pe rty Owner :(~Y' (~-~<~
/
Mailing Address:
3. Name of Buyer:
Mailing Address:
4. Name of Lending Institution:
Mailing Address:
FEB 8 1977
RECEIVED
FHA CONV J
Day Phone:
5. Name of Realtor or Agent:
Mailing Address:
6. Legal Description:
Location:
7. Type of Facility to be Inspected:
8. Water Supply
Type of Supply: Public Utility Individual
ge
If Individual, number of dwellings presently served
If Individual, depth of well
Sewage Disposal System
Type of System: Public Utility
If Individual, date of installation
Individual (on-site)
72-003(3/76)
19~LI~C~PAL~'Y Cf ANCHORAGE
DEPT. OF HEALTH &
rr. NVIEONMENTAL pl~OT f. CTIC~I
FEE 9 1977
EE EIY_ED.
Page 2 of two pages - ReA"~yt for Approval of Individual S~.r & Water Facilities
.Lega! Description Lot 28A Eagle River Valley Ranchettes
Coranents
Approved
~'/2'~-- '"~'App~ Disapproved Date -~-/0- 72
1 ~Valid for one year from date signed
Greater Anchorage Area Borough, Department of Environmental Quality
DIAGRAM OF SYSTEM
I certify that the information contained in this request for approval to be a true and
accurate representation of the subject sewer and water facilities and these facilities
are operating satisfactorily.
SIGNED Date
EQ-034 (~/74)