HomeMy WebLinkAboutSAND LAKE #2 BLK 1 LT 1319 WeiTk�40w�� 11�132�12 Expired Permit 7/13/2001 Municipality of Anchorage George P. IVuereh, Mayor Department of Public Works Building Safety Division P.O. Box 196650 • 4700 S. Braga« Street Anchorage, Alaska 99519-6650 • (907) 343-8301 littp : //«-%N-%v. ci. ane h orage. alc. us John Colliander 8920 Green Belt Dr. Anchorage AK 99502 Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW000323 Legal Description: Sand Lake #2 Blkl Lt 13 Dear John Colliander: An On -Site Water/Wastewater Permit, number SW000323, issued by this office for a single-family system, will expire on August 23, 2001. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit may be issued free of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit. When applying for anew permit, the fees are: $320.00 for a wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerely, 01 'r/ Jame ross, PE Manager On -Site Water and Wastewater Program enc: Copy of permit MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW000323 Legal Description: Sand Lake #2, Lot 13, Block 1 Design Engineer: 0093 G. Scott Crowther, PE Owner Name: John Colliander Owner Address: 8920 Green Belt Dr. Anchorage , AK 99502 - Date Issued: Aug 23, 2000 Expiration Date: Aug 23, 2001 Parcel ID: 011-132-12 Site Address: 5115 W. 82nd Ave. Lot Size: 6750 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: ❑� Disposal Field ❑, Septic Tank ❑ Holding Tank ❑ Privy Private Well El Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: rr Issued By: `"`� 11/ Date: %, / 2 c.5p d Date: P ._ 2 3 —0a 001.039 August 14, 2000 Municipality of Anchorage Department of Health and Human Services Environmental Services Division 825 L Street, Suite 502 Anchorage, Alaska Permit Application On -Site Disposal System Sandlake Subdivision #2, Block 1, Lot 13 Anchorage, Alaska CROWTHER ASSOCIATES This letter request a permit to install a deep trench on-site septic system at Sandlake Subdivision #2, Block 1, Lot 13, which is in Anchorage, Alaska. We intended to install a septic system for a three bedroom house during the fall of 2000. This application has been prepared in accordance with Anchorage Municipal Code section 15.65, which is titled Wastewater Disposal. The application addresses required items of that code. Site Plan and Sematic Trench Dimensions Presented in this application are: • Plate 1, which presents the proposed location for an on-site class C well, existing septic system leach fields, proposed septic system leach fields, proposed 1000 gallon septic tanks, lot lines, proposed building layouts, and existing topographic contours. The ADEC has approved a request to install a Class C well, which will be located as shown on Plate 1, along with a waver of its required septic field separation distance from 150 to 100 feet. • Plates 1 and 2, which present proposed septic system layout and dimensions for the deep trench, piping, septic tank, and cleanouts. • Plate 3, which presents distances to all septic systems, wells, drainage courses, roads, and property lines. • Plate 1, which presents the location of the exploration test pit and percolation test performed at Lot 13. • Plate 1, which presents topographic contours of Lot 13. The area around Lot 13 slopes downward at about a 5 percent grade to the east. Runoff does not pond on the site; it flows to the east. On -Site Septic System Design Design calculations for the on-site septic system are attached. Test Pit and Peculation Test Data A test pit was excavated to a 16 foot depth and a percolation test was performed next to it at the location shown on Plate 1. A description of subsurface conditions encountered and percolation test data are presented on the attached standard MOA Soils -Log Percolation Test form. Adjacent Property The proposed and alternative septic systems will not adversely impact adjacent wells, wastewater systems, reserve space and drainage. We trust this provides the information you require. Please call if you have questions. Yours truly, X"e u� G. Scott Crowther, P.E. Civil Engineer 6491 Page I P.O. Box 110854, Anchorage, Alaska 99511-0854 Telephone (907) 349-2198 / Telecopy (907) 522-3885 Email: crowther@alaska.net a n� ayi — c cv E o c, }no UD9I0 agnl bulao}iuow }no UDalo t c V o }no UDDlo 0 }no uDap 'D C O .0 O_ V V v a� o }no uDalo O Lq CO }no UDaI3 w c 'o 0 a' }no UDaI3 uoi}opunoj 0 — Q) V 0 cncn 0 0 U 2 V a C O v V -�' c v 0 •v c o � —'CV d Y N C fn V N-0 ..Fn CO • T 'n o cu � o 0 N � V Q 0 v CLI c v r7 v O O oO J N Y v7 U = O Q m N p C O •> O — a O = O N N Q O O cn ai o 0 O Q C/)N d Q7 M O_ O O 0 Z Q, LZ m U cn c °' Cn 0 0, C) 0 LL cn o U o 0 Q� V L O .� N Z O 0 U C.D EExisting Septic System Trench 0 100 200 1 P -� Proposed Septic System Trench E Existing Well SCALE IN FEET p Proposed Well Crowther Associates Vicinity Map Plate Geotechnical Engineering Services Sand Lake Subdivision #2, Block 1, Lots 13 and 14 Anchorage, Alaska 3 Job No. 001.039 1 File No. 001039P3 I Date August 2000 C _0000 00000a NwLL.�,o° W1N1--NN-�� NWWWjj m 0 11 0(21,03q v 1- 1� %hree ApvSP Per�vl�><,ea�'17 r �L-e o 2 f Teen c 1, u r -ea 2 /ad 2 4) 7 5� 3 375 Cl' r d f SaF A ° 494 'off -P p G. SCOTT CROWTHER of CE - 6491 pROFESS�D�1'���"°'� MOM rc Municipality of Anchorage . Al,C9 DEPARTMENT OF HEALTH & HUMAN SERVICES `V: 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG — PERCOLATION TEST PERFORMED FOR:�D�//C/Y/C1 E'd'" CO �-'$!' DATE PER FOR LEGAL DESCRIPTION: y&,4,7,4 CI,4rr* DEPTH (FEET) (�%(i(i1J/3i 7//fiYIG r: 1 - 2- 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 1E 1� 13a y (P A p y - z ownship, Range, Section: SLOPE WAS GROUND WATER ENCOUNTERED? /✓o S IF YES, AT WHAT L O DEPTH? P E Depth to Water After Monitoring? A/p Date: 70 P G. SCOTT CROWTHER - AAO E Reading Date Gross Net Time Time 20 Depth to Net Water Drop 14 5 G 3 /ef- 0 7 314- /4-2S /26 /¢ 0 314- 20 PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER TEST RUN BETWEEN IS FT AND Ir FT COMMENTS PERFORMED BY: Sr 0T� CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev. 4/85) S 7 F_� I �� � L E U, L n" S 1L."( L DEPT. OF ENVIRONMENTAL CONSERVATION DIVISION OF ENVIRONMENTAL HEALTH DRINKING WATER AND WASTEWATER PROGRAM 555 CORDOVA STREET ANCHORAGE, ALASKA 99501 July 21, 2000 G. Scott Crowther, P.E. P.O. Box 110854 Anchorage, Alaska 99511-0854 Re: Sand Lake Subdivision #2, Block 1, Lots 13 & 14 ADEC #0121-DW/WW-187-703 Dear Mr. Crowther: TONY KNOWLES, GOVERNOR Telephone: (907) 269-7519 Fax: (907) 269-7650 I have reviewed your new construction the Class "C" drinking water service with a waiver to reduce the separation distance from 150 feet to 100 feet. The waiver is granted for a reduction to 100 feet.. Attached, you will find the Class "C" Inventory and Source Registration Form for this construction. The form has been marked with what has been submitted. Please proceed with the construction. Inspection and sign -off of as -built plans shall be performed by a professional engineer registered in the State of Alaska. Arrangements for this inspection are the responsibility of the developer. This approval does not imply the granting of additional authorizations, nor obligate any state, federal or local regulatory body to grant required authorizations. If construction or operation have not begun with two years after issuance of plan approval, the approval is void, and plans must be submitted to the Department for review and approval. Any future expansion of the subject project will require additional approval from this office. All future correspondence should include the above project number. Respectfully, William R. Rieth, P.E. Environmental Engineer WRR/lb Enclosures: As stated