HomeMy WebLinkAboutBEVERLY HEIGHTS LT 4 -' Municipality of Anchorage Page ]' " DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report 3 Remarks: Original design for 3 bdrms. BENCH MARK Owner requested installation for 5 Location and Oescription: b~ ~,,~ing c~n~-c~ion. A~- Grade at foundation at cleanout. builts reflect design change and show futurc rcplaocmcnt 3itc. I AsaumedElevaflo.: I 127.5 From Well 102 104 Surface Water ~'100 Lot Line 22 10 Foundation 68.~ 70 Curtain Drain {-100 +100 Class,hcabon (Pr,vate. A.EI,C): Tot th: I Cased TO: Total absorption area: F, F,. 660 SO ~, Ordler: ~ :I $lahC Water Level: Installer: ~,. Hamann Constr. ~ Gp,~IPumps"l't: ., Ic's'""""g"lA~°v'G'";: TANK SEPARATION DISTANCES ~ Septic Tank F,eld StahO" Tank SewerLine~ Anch. Tank Material: Steel LIFT STATION ~ "Pump on" level ~f" level at: I High water alarm at: ~el I Electrical Inspections perlormed by: Inspechons performed by: C~. Dates: ls~~ Departme.t of Heal~ and Hu~ Se~lces approval. Reviewed and approved by: Date: n Holding [] S.T.E.P. Cap~i~y~n~a.ons: Tolal Depth from original grade: 10' Gravel depth beneath pipe 6.0' Gravel length: 55 ' F810; D3034 7-19-94 Ft Permit Number: SW940247 PID Number: 051-232;,51 Name: Judy Kleven Wastewater System: I~ New [~Upgrade Address: 18905 Beverly Drive, Chuqiak ABSORPTION FIELD Phone688--2759 INo'oI~edr°°ms: ~DeepTrench [] ShaIIow Trench r-IBed []Mound []Other LEGAL DESCRIPTION soi, Ra,,ng: 1· 2 GPD/Sq FI Lo~ ~e,ock: Beverly 11e~ghts 6.0' ~, Township: I Range: I Section: Fill added above original grade: 15N 1W ,qW4..~P~IR varies 0 - 2' Ft WELL: [3 New [] Up 2 ' AS-BUILT WASTEWATER ABS[]RPTIF1N SYSTEM LOT 4 BEVERLY HEIGHTS SUB CLEANQUTS (TYP) 1~.~,1500 GAL TAN~ .ICHORAG~ FINISHED GRADE UNCLASSIFIED FILL (FROM TRENCH EX) (~'~O~'~)PIPE BOrln" SEWER ROCK PIPE BDTTOH ~'~TRENCN BOTTOH 55' TRENCH ]~OTTOH OF TEST HOLE 93.5 .I 55' TRENCH 53' 4' FSIO PERFORATED PiPE ~1 ~'~ DESIGN CRITERIA: 1. 5 BEDROOM x 150 GAL/DORM/DAY =750 GPO 2. SOILS RATING 1.2 GPD/SF 3. 750 GPO + 1.2 GPD/SF = 625 SF ABSORPTION AREA 4. 625 SF + (2)(6'D) = 52 LF TRENCH (MINIMUM) 5. 1500 GAL 2-COMPARTMENT SEPTIC TANK PREPARED FOR: JUDY KLEVEN 18905 BEVERLY DRIVE CHUGIAK, AK, 99567 KND ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK, 99577 907-694-2359 AS-BUILT DETAILS WASTEWATER ABSDRPTIDN SYSTEM LBT 4 BEVERLY HEIGHTS SUB PERMIT SW940247 PID 05123251 55'L X 2'W X 6' D TRENCH FUTURE REPLACEMENT TRENCH SITE 1500 GALLON SEPTIC TANK CO C0 TEST HDLE 100' PROTECTIVE ~,/[LL RADIt ING CRIB AND SEPIIC TANK ED AND FILLED WITH SAND PVC 81.8 94.8 76.5 68.5 PREPARED FOR: JUDY KLEVEN 18905 BEVERLY DRIVE CHUGIAK, AK, 99567 KND ENGINEERING 20441 PTARHIGAN BLVD EAGLE RIVER, AK, 99577 907-694-2359 SCAL[, I° · 30' AS-BUILT 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6111/FAX (907)696-8111 July 21, 1994 On-Site Services, DHHS 825 L Street Anchorage,AK, 99501 Dear Sirs: ref: Lot 4 Beverly Beights Subdivision Permit SW940247 Attached are the inspection report, as-builts,and Health authority checklist and application for the subject property. During the installation of the absorption trench the owner requested the system be installed for a five-bedroom house. We redesigned the system to accommodate the owner's request. As shown on the as-builts, the design criteria for a five bedroom system for this property requires a 50' long x 6' deep trench and a 1500 gal septic tank. The area available for a 5-bedroom replacement trench is shown on the system as-built, and is adequate to contain a 50' trench. The 150' protective well radius shown is for a well on the adjacent lot serving two houses. There are two private wells on this property; the controlling well radius is shown. The existing crib was excavated, crushed and backfilled, as was the existing steel tank. During the excavation, we noted that plywood was placed around the perimeter of the crib against the logs. We feel this was the primary cause of failure of the crib by not allowing the free flow of effluent to the perimeter walls. Thank you for your prompt consideration in this matter. If you have any questions, or need additional clarification, please contact me at 696-6111 or leave a message. Sincerely, Kenneth M. Duffus, P.E. KND Engineering Attachments: as stated PAGE 1 OF 1 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW940247 DESIGN ENGINEER:KND ENGINEERING OWNER NAME:KLEVEN JUDITH A OWNER ADDRESS:HC 78 BOX 2315 CHUGIAK, ALASKA 99567-2315 DATE ISSUED: 7/18/94 EXPIRATION DATE: 7/18/95 PARCEL ID:05123251 LEGAL DESCRIPTION: BEVERLY HEIGHTS LT 4 LOT SIZE: 24316 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: RECEIVED BY: ~--~.~ ISSUED BY:~~ DATE: DATE: ~%~D ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 (907)696-6Ill/FAX (907)696-8lll July 14,1994 On-Site Services DH/IS 825 L Street Anchorage, AK 99501 Dear Sirs: REF: Lot 4, Beverly Heights Subdivision Attached is our request for an on-site sewer permit for the above lot. As shown on the site plan, there are no conflicts with existing on-site wells, sewer systems or with potential reserve areas. In addition, the public well is not within 150' of the proposed system. This lot is generally flat with a 2%- 3% slope running south to north and east to west. There is adequate area directly east and west of the test hole location on the lot to install both an original and a replacement system. The natural slope will direct drainage away from the existing well areas. This is a replacement for a failed system. The existing system presents a health hazard and will be properly abandoned during installation of this system. Thank you for your consideration of this request. If there are any questions, please call me at 696-6111 or leave a message. Sincerely, KND Engineering Attachments: On-Site Well and Sewer Application Wastewater Absorption System Details Site Plan Soils Log/Percolation Test SITE PLAN REPLACEMENT ~/ASTE~/ATER ABSBRPTIBN LDT 4 BEVERLY HEIGHTS gU3 / Test SYSTEM LOT SIZE: LESS: PERIMETER HOUSE FOOTPRINT AND DRIVEWAY TOTAL AREA AVAILABLE FOR ABSORPTION SYSTEM 25,663 SF 24,600 SF 1,063 SF PREPARED FOR: JUDY KLEVEN 18905 BEVERLY DR CHUGIAK, AK, 99567 KND ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK, 99577 907-694-:~359 DATE, 7-13=94 I DRA'dlNG # DESIGN DETAILS WASTEWATER ABSORPTION SYSTEM LnT 4 BEVERLY HEIGHTS SUB DJ ~D r-1 CLEANOUTS (TYP) -'r ~z --~T~r.c. ~OTTOM FINISHED GRADE UNCLASSIFIED FILL (FROM TRENCH EX) PIPE BOTTOM SEWER ROCK 38' TRENCH 4' PERFORATED LATERAL (TYP) DESIGN CRITERIA: 1. 3 BEDROOM x 150 GAL/BDRM/DAY = 450 GPO 2. SOILS RATING 1.2 GPD/SF 3. 450 GPD + 1.2 GPD/SF = 375 SF ABSORPTION AREA 4. 375 SF + (2)(6'D) = 31.25 LF TRENCH (MINIMUM) 5. NEW 1000 GAL 2-COMPARTHENT SEPTIC TANK TO HAVE 2' HD INSULATION IF <4' GROUND COVER. 6. TRENCH TO HAVE 2' HD INSULATION IF <3' GROUND COVER. PREPARED FOR: JUDY KLEVEN 18905 BEVERLY DRIVE CHUGIAK, AK, 99567 KND ENGINEERING 20441 PTARMIGAN BLVD EAGLE RIVER, AK, 99577 907-694-2359 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: Judy klevPn LEGAL DESCRiPTioN:LOt 4 Beverly Heights Sub DEPTH (FEET) Organic Brown Sandy Loam 'erc Hole Elev Sand, Brown w/trace of ,Silt- Some lenses of course sand Township. Range. Section: SLOPE 10 - ~ WAS GROUND WATER ENCOUNTERED? L )F YES. AT WHAT N/A O DEPTH? p 12- E ~;m to Wa~r ~.t~rNone 7/13/94 13 - IMonitming? SITE PLAN 14 - Reading Date Gross Net Depth to Net Time Time Water Drop 15 - 0 716194 ,q 0 6" 1 5 min 5 min R q/16" ? q/1R" 16- 3 14 rain 4 rain '7/ 9 )/16 ?'1/1~" 17- 4 1R rain 4 min ll ]/1;" 2" 5 20 rain ? rain 1.t 1/16" ~" 18- 19- * IJ~f~t- nddpr 20 min ll 5/8" 20- PERCOLATION RATE ~ tmlnute~Jinch) PERC HOLE DIAMETER TEST RUN BETWEEN 4 FT AND 5 FT COMMENTS Hnl~ PrP~nnked pri~r tn tP~tfng PERFORMED BY: CA1 / KND I KpnnPth Du ff'u~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DATE: 7/~/94 72-008 (Rev. 4/85) .~GRE~"~,R ANCHORAGE AREA Department of Environmental Quality ~ 3330 CStreet A~chorage, Alaska 99503 NAME ~1~ LOCATION SEPTIC TANK: DISTANCE FROM WELL INSIDE LENGTH INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM ~:t~.~ e~ ~ MAILING ADDRESS PHONE MANUFACTURER INSIDE WIDTH MATERIAL f~'~e~-- NUMBER OF COMPARTMENTS LIQUID DEPTH I IQUID CAPACITY SEEPAGE PIT: NUMBER OF PITS LINING MATERIAL BUILDING FOUNDATION__ O~AME'rER ~,0 oR WIDTH IF,' LENGTH /5', DEPTH ~'' CRIB SIZE= DIAMETER ~iDEPTH ~1 DISTANCE FROM: WELL TOTAL EFFECTIVE NEAREST LOT LINE ABSORPTION AREA (WALL AREA) ~(E,O ADDITIONAL ABSORPTION GALLONS. WELL: BUILDING FOUNDATION CESSPOOL APPROVED CONSTRUCTION ~ r~ IU~tlcJ DEPTH NEAREST NEAREST SEPTIC/.--// LOT LINE SEWER LINE TANK OTHER SOURCES DISAPPROVED REMARKS DISTANCE FROM: SEEPAGE 10~ ~ SYSTEM DISTANCES: DIAGRAM OF SYSTEM INSTALLED BY: PIPE MATERIAL: LOT SLOPE: REMARKS: Form NO. EQ-031 GR~EATeR ANCHORAGE AREA BOROUGH SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT TYPE AND SIZE OF FACILITY TO BE SERVED FINANCED THROUGH PHONE COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF' ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. .pT,c TANK.'EE /~dO ~, ..PAGE AREA .,ZE DIAGRAM OF SYSTEM WATER MAIN TO SEPTIC TANK DRAIN FIELD EEEPAGE PIT /t~n / D.A,N .,ELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF EXCAVATION S FEET INTO UNDISTURBED SOIL. GRAVEl. BACKFILl. CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION. OwNER OF LAND ,J,j~OT ~. ~-.~fftd£r~J I)eI'TIIOF'.vELL ADDRESS ~ ~ / ~o~ ~/~ c ~4,~ STATICLEVELOFWATERFr. LEGALDESCRI~IoN ~-~ ~ ~ ~C~d~ I)RAWI)OWNFT. DATE - St,aed ~/t~ Ended ~-- GA~.PER HR PERMIT NUMBER KIND OF CASING KIND OF FORMATION: From O FI. lo ~,~ Ft. From. ~ Ft. to ..TI Ft. From ~'[ Ft. to .5"~ Ft. From -s~'O Ft. to ~" Ft. From. 1'%~" Ft. to 'fid Ft. From 'c~O Ft. to/~ ~ Ft. From /~D Ft. to /c)l Ft. From /¢~! Ft. to 1~,0 Ft. From I{~ FI. to leJ~O Ft. Fromly'e~ Fl. to ~1~' Fl. From ~)l,e" FI. lo ~2~ Ft. From Ft. lo Ft. From FI. to Ft. From FI. to Ft. From __Ft. lo Ft. From__Ft. to FI. Fromm. Ft. to Ft. Front Ft. to. . Ft. From FI. lo FI, t From __ Ft. to Ft. - ~_.~/"'From ; Ft. lo FI. Front Ft. to FI _ From Ft, to__Ft. From ~ FI. to... FI. Front FI. to ,, , FI. Frolo Ft. lo__FI. ,~,'~ Td~'~7'~eSrom Ft. to Ft. Fro~ Ft. to . Ft. From Fl :i~.~__~.~3 From ~ Fl From . ,: Ft. ,o~,~.~FI, r. From Ft. t o~ .~ItT41H~_.~ t4ou _ From __Ft. to~ From Ft. ~ Ft MISCL. INFORMATION: 77' °c" Tor, - o%0 ,, DRILLER'S NAME , ~MUN I I:: ~'~AL I TY OF ANC~]RAGE ~] -~DEPARTMEN] oW HEALTH AND ENVIRONMENTA~ ~ROTEOTION . 825 L STREET~ ANCHORA~E~ AK ~501 ~ 2&4-4720 ~ ON--S I TE WELL PERM I T F'ERMIT NO: DATE ISSUED: 850574 07/01/85 APPLICANT: ADDRESS: CONTACT PHONE: LEGAL DESCRIP: LOT SIZE: JUDY KLEVEN SR 1 BOX 2515 CHUGIAK~ AK ~9567 688-2&58 SUBDIVISION:~BEYESLY H~IBHTS .......... Lo'T~' 4 SECTI0N: 18' .TOWNSHIP: 15N RANGE: 1W 52000 (SQ.FT. OR ACRES) BLOCK: I certify that: 1. I am familiar with'th~ pequiremmnts for on-site sewers and wells as set ~orth'by the Municipality o~ Anchorage (~OA) and the State of Alaska. 2. I will install the system'in accordance with all MOA codes and pegulations, and In compliance ~ith the design criteria o~ this permit. 5. I will adhere to'all MOA and State o~ Alaska requirements for the set back distances ~rom any existing well~ wastewater disposal system or public sewerag?x/system on this or any adjacent or nearby lot. APPLICANT: _/(] ~L~VEN . ISSUED DY / unicipafity o¥ Anchorage POL ,.,H 6-650 ANCHORAGE. ALASKA 99502-0650 (907) 264-4111 TONY KNOV. q E,~ MA YOt~ DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Permit ~:840040 January 31, 1985 TO: Permit Applicant SUBJECT: Lot 4 Beverly Heights Subdivision A permit issued by this Department for an individual well and/or on-site sewer system has expired as of December 31, 1984. Permits are issued on a calendar year basis by authority of Municipal Ordinance. A new permit must be obtained from this Department for any well and/or on-site sewer system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this Department for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site sewer system, the original as-built inspection report and the yellow copy must be sent to this office for review and approval, and for documentation. If there are any further questions, please call this office at 264-4720. Sincerely, Keith E. Bandt, Supervisor Environmental Engineering Program KEB/lJw enc: Copy of Permit SWP/057 I'lUt~ I C I PAL I T"-r' OF Ftt~OHOR~GE DEPARTMENT OF HEALTH AND EHVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, RK ~3501 264-4720 Cl[~--5 I TE I~ELL PEArl I T PERMIT NO: DATE ISSUED: ~PPLICANT: ADDRESS: CONTACT PHONE: LEGAL DESCRIP: LOT SIZE: LOT LOCATION: JUD~ KLEVEN CHUGIAK, RK D9567 694-2225 SUBDIVISION: BEVERLV HEIGHTS SECTION: ~2000 (SO. FT. OR ACRES) BEVERLY DRIVE LOT: 4 BLOCK RANGE: I CERTIFV THAT: i. I Al.1 FAMILIR.R filTH THE REQUIREMENTS FOR ON-SITE SE~IERS AND ~IELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE (MOA> 8HD THE STATE OF ALASKA. 2. I ~.IILL INSTALL THE SYSTEM IN ACCORDANCE NITH ALL MO8 CODES 8HD REGULATIONS, 8ND IN COMPLIANCE hiITH THE DESIGN CRITERI~ OF THIS PERHIT. '~. I I.IILL ADHERE TO ALL MO8 8ND STATE OF ~LASK8 REQUIREMENTS FOR THE SET B~CK DISTANCES FROM 8NY EXISTING I.IELL, WRSTEPlATER DISPOSAL SYSTEbl OR PUBLIC SB4ERAGE~STEM ON THIS OR 8NY ADJACENT OR NEARBY LOT. RPPLICRNT:~BV KL~EN POUCH 6-650 ANCHORAGE. ALASKA 99502-06,~,0 (907) 264-4111 ~Permit #: 820756 .January 31, 1983 TO: Permit Applicant Subject: Lot 4 Beverly Heights Subdivision A permit issued by this department for an individual well and/or on-site sewer system has expired as of December 31, 1982. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log needs to be sent to this department for documentation of the installation date and to close the permit. If a private engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files and documentation. If there are any further questions, please call this office at 264-4720. Sincerel~ Robert C. Pratt, R.S. Acting Program Manager Sewer and Water Program RCP/ljw enc: Copy of Permit SWP/057 PER, MIT NO. FIPPL I CRNT LOCRT I OH LEGAL JUDY KLEVEH L4 BEVERLY HTS SR 80X 2~15 BI.I 99567 LOT SIZE 688-2638 999'99'3 SQURRE FEET MIHIMUti DISTRNCE BET;.IEEN 8 WELL 8ND RHY ON-SITE SEWRGE DISPOSBL SYSTEM IS ±00 FEET FOR R PRIVRTE 14ELL OR 158 TO 200 FEET FROH B PUBLIC WELL DEPENDING UPOW THE TYPE OF PUBLIC WELL MINIMUM DISTBNCE FROM 8 PRIVRTE NELL TO R PRIVRTE SEWER LINE IS 25 FEET RND TO 8 COMMUNITY SEWER LINE IS 75 FEET. 14ELL LOGS BRE REQUIRED BND MUST BE RETURNED TO THE DEPORTMENT HITHIN ~0 D8'¢S OF THE NELL COHPLETION. OTHER REOUIREMEHTS MRY 8PPL%'. SPECIFICBTIONS 8WD CONSTRUCTION DIBGRBMS 8RE RVBILABLE TO INSURE PROPER INSTBLLBTION. PEF-:t4 I T E,"-~ P I I~'E'--'": [:,ECEt-IBEF: --~---::t... I CERTIFY' THRT l: I R£'1 FRHILIRR WITH THE REQUIREMENTS FOR ON-SITE SEI4ERS RND WELLS RS SET FORTH E:Y THE MUNICIPRLITY OF 8NCHORRGE. 2: I~NSTRLL THE SYSTEM IN RCCORDRNCE WITH THE CODES. s ............ MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES DiL, ision of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 051-232-51 HAA# ~ (~OI ~'1 ~"~ ~"'~ L'~ 1. GENERAL INFORMATION Complete legal description Lot 4, Beverly lleights .,{.L,~ocation (site address or directions) ~,....~roportyowner Judy Kleven '~.~'M~[i~"~'dd~;es~ 18905 Beverly Drive, Chuqiak, ~.~:~ '~ ,,. . ~.' ~ndmg agency C~ty Mortgage Mailingaddress 18905 Beverly Drive Day phone Alaska 99567 Day phone Agent Day phone Address 688-2759 2. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Unless otherwise requested, HAA will be held for pickup. 5 NOTE: Individual well XX Community well Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OFWASTEWATER DISPOSAL: NOTE: XX Individual on-site Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legafity and status of system. 5. STATEMENT OF INSPECTION BY ENGINEER Se As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or waste.water disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm KND Enqineerinq, Ken Duffus, P.E. Phone 694-2359 Add~ess ??ti41 Pearmlgan Rlvd.. Eaqle River. Alaska Englneer'ssignature ~' ~ Date DH.H~.IGNATURE Approved for ~" 99577 bedrooms. Disapproved. __ Conditional approval for bedrooms, with the following stipulations: Additional Comn~ents Date The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska, The DH HS does this as a courtesy to pu mhasers of homes and their lending institutions In order to satisfy certain federal and state requirements, Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the p?ofessional engineer's work. Municipality of Anchorage Department of Health and Human Services HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: Lot 4, Beverly Heights Parcel I.D. 051-232-51 A. Well Data Well type Ind. Log present (Y/N) Total depth 220 Sanitary seal (Y/N) Y Y If A, B, or C, attach ADEC letter, ADEC water system number Date completed 6/85 Driller Sullivan Cased to 77 ' 8" Casing height 1.5 ' Wires propedy protected (Y/N) Y Date of test Static water level Well flow Pump level1 FROM WELL LOG AT INSPECTION 6-85 6-24-94 75' 65' 3 g.p.m. 5.1 unk 210' SEPARATION DISTANCES FROM WELL TO: Septic'holding tank on lot 102 ' Absorption field on lot 104 ' Public sewer main NA g.p.m. ; On adjacent lots + 150 ' ; On adjacent lots +100 ' Public sewer manhole/cleanout NA Sewer service line 36 ' Petroleum tank + 100 ' WATER SAMPLE RESULTS: Coliform 0. 7-18-94 Nitrate 0' 6-17-94 Other bacteria 0. 7-18-94 Date of sample: See above Collected by: CAL B. SEPTIC/HOLDING TANK DATA Date Installed 7-19-94 Tank size 1500 Clea~o,~t~'(Y/N) ' Y Foundation cleanout (Y/N) High ~ater alam3 (y/N) NA D.ateo. fp~mping. NA - New installation Pumper S~ATION DISTANCE~' FROM SEPTIC/HOLDING TANK TO: Well(s) on lot 102 ' To property line 22 ' Surface water/drainage On adjacent lots Absorption field +100' +150' 6' Compartments 2 Y Depression (Y/N) Alarm tested (Y/N) N Foundation 68.5 ' Water main/service line + 7{') ' z~-o2e (~3)' Fm~t CONTINUED ON BACK PAGE C. UFT STATION · Date installed Manufacturer Size in gallons Manhole/Access (Y/N) Vent (Y/N) 'Pump on' level at ~at High water alarm level ~..~"y~d · Meets MOA electrical codes (Y/N) SEP~ATION TO: , ..WeF~n Io~ On adjacent lots Surface water D. ABSORPTION FIELD DATA Date Installed Length:':, 55' Total absorption area Date of adequacy test Water level in absorption field before test Peroxide treatment (past 12 months) (Y/N) SEPARATION DISTANCE FROM ABSORPTION FIELD TO: Well on lot 104 i To building foundation 70 i On adjacent lots + 50 ' Sudace water + 100 ' Curtalr~ drain +1001 7-19-94 Soil rating (GPD/Ft~) 1.2 Width 2 ' Gravel thickness 660 SF Cleanout present (Y/N) ¥ NA - New sySt~sults (pass/fail) System type Deep trench varies 10- Total depth 12 ' Depression over field (Y/N) N for After test If yes, give date On adjacent lots + 150 ' Property line 10 ' To existing or abandoned system on lot 20 ' Cutbank +50 i Water main/sen/ica line +75 i Driveway, parking/vehicle storage area + 501 Bedrooms E. ENGINEER'S CERTIFICATION I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Waiver Fee $ Date of Payment Receipt Number Ztr CT&E R~f.# Cli~t Sample ID Matrix ClientName Ordered By Project Name Project# PWSID Sample Remarks: Commercial Testing & Engineering Co. Environmental Laboratory Sewices 94.3011-1 L4 BEVERLY Iris WATER BLS & ASSOCIATES, LNC UA LABORATORY ANALYSIS ~EPORT WORK Order 79583 Printed Date 06/23/94 ~ 16:37 hrs. Collected l~te 06/17/94 ~} hrs. P~ceiv ed Date 06/17/94 ~} 14:30 hrs. Technical Director STEPHEN C. EDE ROIH'Rq~ SAMPLECOLLECTED BY: BLS. Parameter Resul~ Ni~,'ate-N 0.10 qc ~ units U rng/L Method EPA 353.2/300.0 Allowable Ext. Anal Limits Date Date Init 10 06/'20/94 Cl~. * See Special Instructions Above ** See Sample Remarks Above U = Undetected, Reported valm is the practical quantification limit. ~ D = Secon&ry dilution. UA = Unavailable NA =Not Analyzed LT= Less l~an O'F= Greater 'limn 5633 B Street, Anchorage. AK 99518-1600 -- Tel: (907) 562-2343 Fax: (907) 561-5301 ENVIRONMENTAL FACILITIES IN ALASKA, COLORADO. FLORIDA. ILLINOIS. MARYLAND, NEW JERSEY. OHIO. UTAH. WEST VIRGINIA Plat Status: Final BOROUGH:. Engineer ~ealth Department Public Uorks Department Sand Lake Fire Department School District Tax Assessor A~aska Department of Eighway~ Anchorage Natural Gas Co~p. Central Alaska Utilities Uhu~ech. Electric Association Description of Property: See attached plat. CITY OF ~;O~ORAGE: Fire lI~rshal Hunicipa! Light & Power Departnen~ Property Hansge~nt Officer ~ Public Works Departs, ant ;. Telephone Utility · Traffic ~n~ineer l~ter Utility ~AB Teleco~unlcations, I~c. Hatanu~ka Electric Association /Iatanuska Telephone ~so¢iation Assistant Superintendent of }lall~ , Raymnn J. and Beverly J. Emmons Gentlemen: Petition has been received by the Greater Anchorage Area Borovsh Pla,minE ........... and Zoning Commission for the proposed subdivision of ~ubJect property. Attached is a copy of ~e proposed plat. Will you please submit your comments in writing, specifying any easements er other requirements that your department or a~ency may need. If we do not hear from you by 8/21/70 you do not wish to submit any comments. , we will assur~e that · If you have no further use for the attached.print, please return it with your co~-aen ts · Plannin$ Departuent Enclosure