Loading...
HomeMy WebLinkAboutNORTH WOODS BLK 4 LT 19- Municipality of Anchorage Page DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number: ~'~CJ~'~) L~ Name: ~ ~ ~~ ~ WastewaterSystem: ~ New O Upgrade Phone: ~--~0~ '1 ' :3 =D.pTrench ,ShallowT.nch ~Bed =Mound =Other WELL: O New IPumpset at: pt. I Casmg ~e'gm ~ove Greu;:: SEPARATION DISTANCES Wel~ ~ ~ - . · Lot ,o~..,,o. D~' 17' 2)' cu~,. N r~ Remarks: TANK i'1 Septic t-I Holding 1'I 9.T.r-.~,~OC ~l~. LIFT STATION s'i'~;~'~': I"'"~'~"''~' ~:~¢ w/~ "Pump on" level et: "Pump off" level al: High water alarm ~.vs" I ,~.'~" I ~,.as" BENCH MARK ~ po,~ Dates: 1st q.-13-q~ 2nd ~~~Z'tlq 17034 Eagle River Loop Road, No. 204 Inspections pedormed by: Eeqle River. Alaska 99577 Department of Health and Human) Services apprqva! Reviewed and approved by: '~.~/'~l../~.~ Date: PERMIT NO. SW980428 PAGE 2 OF Munlcip. oH~ o? DEPARTMENT OF HE~_THAND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 eAnchorc~ge, AIo. sk~ 99519-6650eTetephone' 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT L~CAL LOT 19, BLOCK 4, NORTH WOODS S/D P.[.D, No. 051-741-02 I lOX15 I Anchor Esm~ P£~IT No. SW980428 un~op, ct · o Anchor'oge. DEPARTMENT OF HE~_TH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 eAnchor~ge, Al(lsk(i 99519-665Oe Tetephone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LECAL LOT 19, BLOCK 4, NORTH WOODS S/D PJ.D. NO. 051--741--02 MANHOLE J1 A B C L FCO - 48,5' 10.0' BIO - 4;5.0' 41.5' BIOCYCLg ~,rl 52,0' 40.7' - UNIT ~r2 44.0' 23.0' - ~Ir 3 83.0' 43.5' -- ~,~r4 85.5' 52.5' - TBM: TOP OF GARAGE SLAB ....... ASSUMED 100.0' MT2- - MT~._]MT~ = 10~'.0', / IMT2 = 105.0 __~ /FINAL GRADE .................................... /2" INSULATION SR A NO WATER FOUND MT2 = 100.0 ~"-MT$ = 100.0' B.O.H. MT4 = MT4 -_ MT I._]MT 1 = 10'LO' / IMT4 = 107.0' ~ /FINAL GRADE 102.0' MTI = 101.0' . CARCEL ELECTRIC INC. 10410 FtN~.EY CIR. · 'ANCHORAGE, AK. 99518 90?-346.4030 · 907.34~.4032 ~ Tweed Excavating 17034 Eagle River rd. #202 Eagle River, AK 99577 To whom ~t ma~ concern= RECEIVED AUG lO 1999 Munlcip.~lity ot Ancl~orage Dept. Health & Human Services ~ul¥ 14,-1999 Cagcel Electrlc wired the Bio-Cycle located et 22733 Nc~enna Lot 19~ Bk-4, Northvoo~ls Sub., Chugiak RK. ' This Bio-Cycle was wired per the 1996 National Electrical Code. If you have any questions please give me a'call% Thank you, Steve Cloud General ~ana~er MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-Site Services Program 825 L Street, Room 502 P.O. Box '196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT L~ te Issued: Nov 04, 1998 Expiration Date: Nov 04, 1999 Permit Number: SW980428 Legal Description: NORTH WOODS BLK 4 LT 19 Design Engineer:. 0003 S & S Engineering Owner Name: Robert A. Shafer Owner Address: PO Box 773303 Eagle River, AK 99577-3303 Parcel ID: 051-741-02 Site Address: Lot Size: 24854 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of: [] DisposalField [] SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Ddnking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours pdor to each Inspection. Provide notification by calling (907) 3434744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either:. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. This permit is for a BioCycle Received By: Issued By: September 9, 1998 ROBERT C. COWAN. RE. ROBERTA. SNAFER. RE. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 lVlUNICIPALITY OF ANCHORAGE Department of Health and Human Services P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 19, Block 4, North Woods Subdivision Request you issue a permit to install an innovative (BioCycle) system to serve the proposed three bedroom house on the referenced properD'. One test hole was excavated and a percolation test was performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation, ground water was encountered in the test hole at 10 ft. After seven day groundwater monitoring, the monitoring tube was checked and the ground water level was found to be at 8.5 feet. We do not anticipate any adverse effects On neighboring wells, septic systems or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on adjacent properties. This subdivision is serviced by a Class "A" water system. If you require additional information, please contact us. Sincerely, /;:t2 Robert C. Cowan, P.E. RCC/srj Enclosure 17034 NORTH EAGLE RIVER LOOP * SUITE 204 * EAGLE RIVER. ALASKA99577 PHON[I (g07)694-2~79 Z Z s.r.d, r.c.c. I rev~se~ ~o-~-~1 ~ or ~ STRUCTURES. CASEMENTS. OR ENCROACHMENTS ~IIOWN ON Tiffs SITE PLAN AR[ AS SIiOWN ON WILLIA~ FL[~ING ~. D ISTANC,S. AND PROPERTY LINES PRIOR '0. CONSTRUCTION. ~ ~x~ /,??, /' , , OGTAIN UTILITY , , F 78' LONG (2039') j ~IOCYCLE UNIT SlT~ ~ PROPOSED FI~ ~ ~ ~ DESIGN CI{I'I'EI{h\: 3 BDRM = 450 GPD / SOILS -- 0.4.5 GPD/SQ.FT. / 450/0.45 = 1000 SO.FT. REQ'D./ AREA/2 FOR BIOCYCLE = 500 S,Q. F'T. 500 x 0.78=.390 SO. FT. / ~TRENCI.I CRITERIA: 4' DEEP 1.5' EFFECTIVE 5' WIDE 78' LONG (2039') ALT. CI¢.ITERIA: 4' DEEP 1,5' EFFECTIVE 5' WIDE Z 3 BDRM = 450 GPD SOILS = 0.45 GPD/SQ.FT. 450/0.45 = 1000 SQ.FT. REQ'D. AREA/2 FOR BIOCYCLE = 500 SQ. FT. 500 x 0.78 =$90 SQ. FT. PROPOSED WATER SERVICE LINE 'TI:~E NCH CRITERIA ,o .- 4' DEEP 1.5' EFFECTIVE DRIV 5' WIDE 78, LONG ~ ~ROPOSED DRAINFIELD ALT. CRITERIA: BIOCYCLE UNI 4' DEEP 1.5' EFFECTIVE ~ ~ . 200' WELL RADIUS ............. ~STRIBUTIO~--~~[] ........... ~ ~'"'' ~l ALT. S~ITE PUMP = MYERS M~40 (~60GPM) 2 LATERALS ~ 5g LONG = 50 GPM/LAT. 56 HOLES TOTAL = 1.65 GPM/HOLE 1/4" DIA. HOLES FACING DOWNWARD 1 1/~" DIA. LATERALS ~L~ PoR'rlo~s or HOLE SPAGING = 2.0' ~rm I.~ss tn~ as' or / COVER REqUiRE INSUl~'rlo~. '"~" I,()T 19, III,OCK ,1, NOR'i'll WO01)~ ,'-;/1) S.R.J. R.C,C. 9-1-98 3 OF SIDE VIEW 5' WIDE SIIALLOW TRENCII I)ISTRIBUTION SYSTEM: PUMP = MYERS ME40 (~60GPM) 2 LAIERALS ~ $9' LONG = 30 GPM/LAI. $6 HOLES IOrAL = 1.65 GPM/ItOLE I/4' DIA. IIOL[S £ACING DOWNWARD I I/4' DIA. LAIERALS IIOLE SPACING -- 2.0' '"* I,OT 19, IH,{}(;I{ ,1, NOI~.'I'II XY()OI)~ S.R.J. R.C.C. 9-1-98 4 OF BIOCYCLE WASTE WATER TREATMENI SYSTEM 5.94" COVER 7.6' (2.~,~) I i--2.95" / / 6.97' ~////////////////////~ , ..,-- X-SECTION TANK 5,94" PERFORMED FOR: Municipality ol Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST 13- 14-; 15- 16- 17-; 18- 194 20- Township, Range. Section: SLOPE SITE PLAN ENCOUNTERED? IF YES. AT WHAT DEPTH? /O Mon,0ring? ..r ////'"Date,: C,,, /Z.. · - Gross Readihg Date Time / 6 "7 S L O P E PERCOLATION RATE · '[EST RUN BETWEEN. ?n ~. >~ .-' ~-/' I,/,,. s~. 6 l 4' I Net DeDth tO Net Time Wate~ Dr(~D Cd IO;~°h ~ ~" I*~ {mlnutes~nchl PERC HOLE DIAMETER S & S ENGINEERING '/ / 17034 Eagle River Loop Road No. 204 FERFOPMED BY; E=gle River, Ala3ka 295,77 I///~"~'3. . ~ CER'[IFY '[HAT '[HIS '[EST WAS PERFORMED IN ACCCf~DANCEWITHALLSTATEANDMUNIClPALGUIDELINESINEFFECTON'[HISDATE. DATE: ' Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage. Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST PERFORMED FOR: ~" ,"~ ~ 1 - ,,R ,,7 ' LEGAL OESCRIPTION:~'- 4~ '~""/d~/ ..~ ,~ / ~, /~,,.',~ .e'~'~.o'_w.'r~ship, Range, Section: ELOPE WAS GROUND WATER ENCOUNTERED? x S / L IF YES. AT WHAT /~. 0 DEPTH? p De,th to Water Ntor · Monitoring? , /': Oat~. Gross Reading Date Time Net Time .'.,,/ 13- 14- 15- 16- 17- 18- 19- SITE PLAN I Oe[3th to Net Water Drop ,~ '~7~, " l/A," ~ " i~, g-' /~ ~" /" 20 - ,~/-; ~,,- /, .x,: ~ ~z'=.-/-I~; ~' ~..J PERCOLATION RATE .'~*'~ tm.nutes/sncr~l PERC HOLE DIAMETER TEST RUN BETWEEN '~ FT AND ~ FT COMMENTS 5 & S ENGINEEEING 1 ' ' ' ' 7034 E,~jI. R,.~r Loop Koad No. 204. , -- -'// ~ PERFORMED BY; Eagle River, Alas~ca g9~77 I ' '[~' / ~' -: ~ ~ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: I I / ~ / ~ ~ 72-008 (Rev. 4/85) ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS ROBERTC. COWAN. RE. ROBERTA. SHAFER. P.E. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 REFERENCE: Lot 19, Block 4, North Woods Subdivision August 4, 1997 GENERAL: The scope of this project includes the installation of an "innovative" Biocycle Wastewater Treatment System and two drainfield trenches to serve the proposed three bedroom residence to be located on the referenced property.. Construction shall be in accordance with the approved site plan and desi~ drawings, M.O.A. permit xvith any special provisions or conditions, and all applicable Municipality Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wastexvater disposal systems must be familiar with construction practices in this area and either be certified by the Municipal Health Department or have been previously certified under the D.E.C. certification program. Oxvners installing their own systems must also receive prior approval from the M.O.A. ABSORPTION TRENCII/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom &the excavation shall be within 2 inches of level. If the sidewalls ofthe excavation become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed betxveen the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 ,, EAGLE RIVER, ALASKA 99577 Page Two Lot 19, Block 4, North Woods Subdivision August 4, 1998 Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. MINIMUM MATERIAL SPECIFICATIONS: Any septic tank proposed for installation must be constructed by a Mm,icipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipalit3' of Anchorage: Type o f Pipe Perforated Solid Cast Iron Yes ASTM D303-1 (PVC) Yes ASTM F810 (HDPE) Yes ASTM D2662 (/kBS) Yes Yes Yes No Yes Use ora type of pipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Swrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder. Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (server rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements. Page Three Lot 19, Block 4, North Woods Subdivision August 4, 1998 INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank max, be set in place, but may not be backfilled before this inspection. The second inspection must.be conducted after the placement of the silt bah'let, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the properD.'. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus. the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The o~vner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. 5; & S Engineering shall be the o~vner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. $ & S Engineefing's inspecting engineer will not be responsible for the construction means, methods, techniques. sequence, procedures or the safety precautions incident to this project. CONTRACTOR/INSTALLER PROPERTY OWNER AGREEMENT FOR TItE MAINTENANCE OF AN ON-SITE WASTEWATER DISPOSAL SYSTEM This agreement, dated August: 17 1999, is made between the Municipality of Anchorage Department of Health and Human Services (DHHS) and the property owner(s) of: Lot 19, Block 4, Northwoods Sutxlivision This agreement is made for the purpose of maintalnlng aa on-site wastewater disposal system on the subject property. The property owners agree to th, e following: Submit to the Municipality of Anchorage, on an annual basis, an inspection and operation statement from a registered professional engineer. Th.is inspection and operation statement shall verify that the engineer has inspected all effluent and air pumps, timers, and alarms, and that any deficiencies have been repaired and that the system is functioning as designed. (Sigmmre) (Signature) Troy K. Laird ..NOTARY.. ~gZg 'X V "[(~.~x~'xsSN'o t ar = e Here) Teri D. taird (Printed Name) ~".':.Cyc]e,~LASKA W^STEW^TE~ TREATMENT SYSTEM S .'. ?~ ~}3 McM~m~s ~lve ,13630 ~ R~ ' · .. .,' I. - DEPARTMEN'[OF & HUMAN SERVICES . .... Division of Environmental Services . .... ,-~: :..- ...... · --~" ': :On-SiteServicesSe~ti6n ..... '. '*~' · '.:., ,...- ,.. ........ ·. P.O. Box 19~50 .~ Anchorage. Alaska. 99519~650 ~; ~ .:.. · ." '- . ,':: :~ .~.-.~,~.~.)~:~, ./,~ ,, · '.~': -.:'.', .... ~343~7~. : , . ~ .... ~ ...... . ';-,',': -.- ~ .. ,, ., CERTIF CATE OF H~ETH A~THORI~., - ' ' ' ~ ...... '-"'7 ' APPROVAUFOR A SINGLE FAMILY DWELLING ' ~ ": / 1." GENERAL INFORMATION .,. ~ .,: ~'~'=:1 ~?.: ~.¢~ ~,.~a ~.'~ ~: :.c=~; , - oca.~gn,(site~address or d~recho, s) ;~ . ~ B[O~owner;T.he. ~homas~Co./Eike ..~ho=as, ¥ .-~ Da..hone. · =.~ Lending agency = · ~ '- ~- ' ...... ' - ' ....... Day phone ~a ngaddress x ~ Ageht,- ~" ' ~ ...... ,' ' ' ~'' *[D~yphone - '" Address ":' "' ' ' less oth e u t ~ill Id ic **. ~". ~ . ~ NUMBER OF BEDROOMS: ~ : ~ : .,: * ' "' Individual well'' c0mmbniW well: ,. Public water XXX NOTE: If communi~ well s~tem, provide wri~en confi~ati~n from State ADEC a~est- ;.... ',- !ng to the l~ah~ and s~atus of system. . .. :: , . :~, . :;. · ~.,~ 4. TYPE OF WASTEWATER DISPOSAL: XXX NOTE: Individual on-site -- '(3ommunJty on-site . ... " " ' Public sewer ' "~ ,'; :"- If com~nunity wastewater system.'proc'ide written confirmation from State ADEO attesting to the legality and status of system. ' 5. STATEMENT OF INSPECTION BY ENGINEER '.As certified by,~. y ;:eal affixed hereto and :~s of th~ validation'date shown below, I verify that my investigation 6f this'Health Authority A. pproval app-lication- shows that the ~n"site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure in~:licated herein. I furtherverify that based on th~informationobtained from the Municipality of Anchorage files and fro.m, my investigation and inspection, the on-site water supply and/or wastewater disposal system is in comphance.with all Mumc;pal and State codes, · ordinan, ces, and regulations In effect on the date of this inspection. · * * '. ' - ' . ".-"'Name of Firm - s & s ENGINFE~lN~ ..... Phone En eer's s atu e' '.' "" Date ..... · ' Disapproved.'-:":'~ ............. COnditional approval f(~r Additional Comments 'bedrooms,-.Wlth the following 'sfipulabons: "The Municipality of A..nchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only uPOn the representations given In paragraPh 5 above by an Independent professional engine' registered in the State of Alaska.The DHHS does this as a courtesy to purchasers of homes and their le~ding Institutions In order to satisfy/certai n federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before · certificate is Issued. 'The Municipality of Anchorage is not re~nsible for errors or omissions in the professional engineer's work. Municipality of Anchorage .~ o~ ~~ DEPARTMENT OF HEALTH & HUMAN SERVIC~;;~.~.~.~ Environmental Services Division ~.~'~"- 825 L Street, Room 502 · Anchorage, Alaska 99501 · (907) 343-4744 Health Authority Approval Checklist LegalDescriptlon:LoT Iff E,L~ck ~ /U~g?I¢~o~).~ ParcolI.D.: 05'/ -'191 --0 ~ A. WELL DATA /~ ,.,~c.~ (_ I.~ Well type If A, B, or C, attach ADEC letter. ADEC water system number Log present (Y/N) Total depth Sanitary seal (Y/N) Date of test Static water level Date completed to Casing h~ Cased w.~c<~e-~ protected (Y/N) FROM WELL~ AT 17$PECTION Well production WATER SAMP~ g.p.m. Nitrate Other bacteria Collected b/: B. SEPTICfllOLDIflG TANK DATA Datelnstalled -//$/=1~ Tanksize ;~-eo Founcl~tioncleanout~lN) ~/~ ~' Depmssion(Y~ Date of Pu'mping ~'/~ '-~¢.~ Pumper C. ABS0RP~ION F1EID DATA Number of Compartments Date install~l ~/I 3 t q o/ ,~i.I rating~[~or fff/bdrm) Eff~ ~m~on ~a~y ~r Da~ of adequ~ ~t ~ /4 ~ ~ ~ g.p.m. (~ .¥5-' System type Gravel thickness below pipe j' ~' Total depth 5" Monitoring Tube present ~) Y~ $ Depression over field (Y/~). ~" 0 Results (Pass/Fall) For ~ bedrooms Fluid depth in abeorptlon field before test (in.);. Fluid depth (ins) Mln~.~atl~''~''~-. Pemxide~th~) Imrserllntgly ~,ftur gal. water added (In.):. Abeorption rate = g.p.d. If yes, give date 72-026 (Rev. 3/g6)* UFT 8TAI'ION Date ,,~led ManholeJAcc~N) High water alarm level Size in gallons "Pump on" level at* 'ld re *Datum }5-0 0 'Pump off level at' I 7 ~/~/ ~' Cycles te~ed SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot On adjacent lots Abeoq3tion field on lot ~ Public sewer main /~/Public sewer manhole/cleanout Sewer/septic s~eo~.e11~ Uff station ,O~o cycL4. SEPARATION DISTANCES FROM SEPTIC2HOLDIIqG TANK ON LOTTO: Foundation ~ 7 Properly line / ~o Absorption field Water main/service line /0 'f Surface waterldraJnage' ]o0 ~ SEPARATION DISTANOE FI:IOM ,I~BOR~I'ION FIELD OH LOT TO: Property Hne ) ~ Building foundation ) ~' Wells on adjacent lots Water main/saUce line Surlace water / o 0 4- Driveway. parking/vehicle atomge ama '/ Curtain drain /~ a,v~, ~¢,~o~v~ Wells on adjacent lots '~ 0 F. ENGINEER'S CERTIFICATION ., c,,,,,o,,,,e,,ce w~ ~,o~ ,~ ,,,.,,,:,o,,,,,,. ,,, .,,~ on .,,s ,,,,,,, Z'~;" Engineer s Name /r~ ~w6~'4- r' /~'' C o/,o/f,o .,, / , [.~\ ma, c. e~,. I,~Z oat. -,,, / '~'~ '~:,,.. "-"°' HAA Fee $ Date of Payment Receipt Number Waiver Fee $ Date of Payment Receipt Number 72..02~ (Rev. 3/96)*