On-Site Wastewater Disposal System Permit
Permit Number: OSP181401 Effective Date: 11/28/2018
Work Type: Septic Upgrade Expiration Date: 11/28/2019
Tax Code Number: 05152114000
Site Legal Address: TROLL KNOLL BLK 1 LT 2 G:1360
Site Mailing Address: 20453 LEPRECHAN DR, Chugiak
Owner: GRACEY WAYNE A Lot Size in Sq Ft: 30076
Design Engineer: C & M Engineering Total Bedrooms: 4
This permit is for the construction of:
D Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
** The Engineer needs to do an additional test hole prior to the construction of the septic field to verify soils and
the groundwater table.. Construction may proceed at your own risk before the 7 day water monitoring is
complete. Please submit stamped and signed results with the As-built Inspection Report. If the results require a
design change, construction of the system will stop pending On-Site review and approval.
Received By: Date: I —//0//e
Issued By: /6r,/ �,-> / Date: 872-g/0
/ ((
Municipality ®f Anchorage
``•.• „tTM•s ,
P.O. Box 196650 ® 4700 Elmore Road
Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997
http://www.muni.orq/Onsite
Development Services Division
On-Site Water and Wastewater Program
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSV181097 COSA#: Permit#: OSP181401
PID#: 051-521-14
Legal Description: Troll Knoll B1 L2
Engineer: CM Engineering
Applicant: Wayne Graces
Your request for a waiver of the required 10 feet horizontal separation from the existing
absorption field to the foundation has been approved. The approved separation distance is 5.0 feet.
In addition,the proposed field does not follow the slope contours. See the approved design for the
location.
Any future upgrade to the on-site wastewater disposal system will require all separation distances
be met or another approval from this department.
r
Waiver is Granted: X Waiver is not Granted:
Date: //Z-945/ Approved by: /fit/ /
Name of Reviewer
**** VARIANCE/WAIVER REVIEW ****
°RUSH / EPLMJS
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On-Site Water & Wastewater Section Fax: 907-343-7997
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 051 521 14
Property owner(s) Wayne Gracey Day phone bZS -2-1 `A
Mailing address 20453 Leprechan
Site address 20453 Leprechan
Legal description (Sub'd., Block & Lot) Troll Knoll B1 L2
Legal description (Township, Range & Section)
Lot Size 30,076 Sq. Ft. Number of Bedrooms 4
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field x Initial - Single Family (SF) ❑
(w/wo ADU)
Septic Tank 0 Upgrade
Duplex (D)
Holding Tank ❑ Renewal ❑
Multiple Dwellings ❑
Privy n (SF and/or D)
Private Well ❑
Water Storage
THIS APPLICATION INCLUDES A WAIVER REQUEST FOR:
none Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
Charles Balzarini, C&M Engineering
(Signature of property owner or authorized agent)
Permit/Rush Fees: 4 glo.tio Waiver Fees: . 3L{k
Date of Payment: Date of Payment: 06/0
Receipt Number: 0 J6-gD Receipt Number: OI23°19
Permit No. 05P 171 t/O, Waiver No. 05 vi?31097
G:\Development Services\Building Safety\On Site Water and WastewaterlForms\Client Forms\Permit Application.doc
Munidpality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE CONPUANCE
OSP181401,Deb Vlhockenfuss, 11/281'
C&M ENGINEERING SERVICES
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water& Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Proposed Septic System replacement for Troll Knoll Block 1 Lot 2
Dear Reviewer,
The above referenced property is currently served by an older, failing 4 bedroom septic system. The
owner would like to replace it with a new septic system.
We are proposing to install a new septic tank, and a new drain field. The old plastic tank will be inspected
and re-used or decommissioned per moa requirements.
Our review of available documentation and field investigation show that this project will not adversely
impact any nearby Wells, Wastewaterdisposal systems, replacement disposal sites, ordrainage flowing
onto and off of the subject property.
The lot is served by a public well and the proposed septic system will be installed outside of the well's
200' protective radius.
Two Waivers are requested for this project:
1. The existing drain field appears to be 5'from the home foundation at the closest point and
approximately 15' of it is within 10' of the foundation. The system has been in place since
1978 with no apparent ill effects to the home. Based on that, we believe this system should
be left in place as a reserve system. The requested distance is 5'.
2. The proposed drain field will be installed cross slope. The elevation difference is only 1' so
the system may be easily installed in the soil strata. Due to the small elevation differential, we
are not preparing a cross section. We believe the waiver should be approved as approval will
have no discernable impact on the function of the system or on this or adjacent properties,
other than to place the drain field in a more desirable location for the owner. The finished
ground surface will be regraded upon completion of the system. The waiver is requested for
the system as shown on the plans.
Included with this letter is a permit application and design package, including plans, specifications, and
calculations. A test hole was excavated, howevera deeper test hole will be excavated to 16' deep during
construction to verify soil conditions and the groundwater table.
Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854-
5558 or by email cqbalzariniqmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, oF
A:rarlet AL440
,* “! m /\
11/07/18 0 / // r�
_ l
F CHARLES G BALZARINI /
001f,- CE13854 ���
Ah-' p4O ESS',*..►
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPUANCI
OSP181401,Deb lhWckenfuss. 11/28'
C&M ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
Residence: TROLLKNOLLB1 L2
RESIDENCE/LOT INFO
number of bedrooms 4 br
Water usage/bedroom 150 gpd/br
Water Usage 600 gpd
DRAINFIELD
system type: CONVENTIONAL
type: SHALLOW
Application Rate 1.2 gpd/sqft
required absorption area 500 sqft
trench width (W) 5 ft
gravel depth (D) 4 ft below distribution pipe
Min Required Length: 50 ft
Total Excavation Depth: 10 ft
Cover: 3 ft
Insulation: 2" blueboard
Effluent Pipe: 4" ASTM 3034
Calc By: CGB Date: 10/30/2018
°F AL.44. 4
g* /49 Ili •Nk *
CHARLES G BALZARINI�
‹<% CE13854 �`� Aler
c�sle ��
O. ESS -'
- xlicxdye
TANK NOTE:TANK SHALL BE INSTALLED NO CLOSER •` pat%. • ewater
THAN 5'TO THE FOUNDATION.TOP OF TANK MAY BE r fi
NO LOWER THAN BOTTOM OF FOOTING TO KEEP IT DFOR ••i•.••. ANCE
•
OUTSIDE OF THE FOUNDATIONS BEARING PRISM. �C/owo.,oSP181401,.=Al - -..,-, tl12.3P.
./.� • • .
? -CHARLES G BALZARIM
° f<,*. CE-13854 ••`�/�
IS
�,o�- TROLL KNOLL BLOCK 1 lll�\N� ��`'
� G�P� ����/ LOT 3 (COMMUNITY WATER) LEGEND
0 CLEANOUT
NO / • MONITOR TUBE
/ EXISTING DRAINFIELD ® TEST HOLE
TROLL KNOLL BLOCK 1
\ LOT 2 TO REMAIN 0.5% \SLOPE INDICATOR
BULL RUN DIVERTER
WATERLINE
N NEW 1250 GALLON TANK
OLD SUNSET TANK MAY
\ BE RE-USED IF IN GOOD
\, I CONDITION. SEE TANK NOTE.
)•'' 'I� NE FCO
5r •
\IVEWA
4 BR HOM 1' CONTOURS
®\
TH-1 SEPTIC AREA
TROLL KNOLL BLOCK 1 NEW 5x50x4'EFFECTIVE
DRAINFIELD
LOT 1(COMMUNITY WATE•
10' UTILITY EASEMENT
100' WELL RADIUS
GREATLAND ESTATES B1 L7 GREATLAND ESTATES B1 L8 SEPTIC
WELL +200' FROM PROJECT / ` AREA
,.,„
SEPTIC AREA / NOTE:
1.THE PROPOSED SEPTIC SYSTEM IS
GREATER THAN:
CONTRACTOR SHALL RE-CONFIGURE PLUMBING INSIDE CRAWL SPACE 100' FROM ANY PRIVATE WELLS
TO EXIT THE FOUNDATION AS REQUIRED TO MEET GRADE REQUIREMENTS 200'FROM ANY PUBLIC WELLS
100' FROM ANY SURFACE WATER
IF PLUMBING CAN NOT BE RE-CONFIGURED,OR LINE GRADES CAN 50'FROM ANY STEEP SLOPES
NOT BE MAINTAINED,A LIFT STATION WILL BE REQUIRED. 10'TO ANY PROPERTY LINE OR FOUNDATION
5'TO ANY TEST HOLES
FILL AND/OR INSULATION SHALL BE PLACED OVERALL LINES. EXCEPT WHERE SHOWN
t
SCALE:1" =40'
LEGAL DESCRIPTION:TROLL KNOLL BLOCK 1 LOT 2
C&M ENGINEERING SERV ICES OWNER:WAYNE GRACEY DATE: 10/30/18 REV: 0 I DRAWN: CB REF:
907-854-5558
SITE PLAN
Municipality of Anchorage
On-site water and wastewater
REVIEWED FOR CODE CONPUANCE
OSP181401,Deb Wockenfuss, 1//28/:
CBM ENGINEERING SERVICES
Ph: 907-8545558
SPECIFICATIONS FOR ONSITE SEPTIC SYSTEM - MOA CERTIFIED INSTALLER
LEGAL: Troll Knoll Block 1 Lot 2
October, 2018
A. GENERAL
1. The septic design is for a 4 bedroom, single family residence only.
2. The site plan and drawings shall be a part of this specification.
3. The Wastewater system shall be installed by a certified installer in accordance All
materials and workmanship shall meet the Anchorage Department of Health and
State Department of Environmental Conservation requirements.
4. All soil tests are advisory to the design and are to be verified or modified in the field
by the engineer. The engineer shall perform percolation tests and groundwater
monitoring prior to finalizing design. An additional Test hole and percolation test is
required during construction.
5. All excavations and depths are advisory and are to be verified in the field by the
contractor to meet Municipality of Anchorage, Department of Environmentof
Conservation requirements.
6. It is the responsibility of the owner to obtain all necessary permits or easements and
to locate any adjacent multi-family wells. A licensed surveyor should locate all
nearby lot lines, easements, exact 100' radius from the neighboring on-site wells,
and any nearby surfacewater.
7. The excavation is to be exactly in the area shown on the site plan, any deviation
requires engineer approval.
8. Any remaining open test hole excavations shall be filled and monitor tube removed,
after construction of the Drainfield.
9. The contractor shall familiarize himself with the new code requirements for
inspection notification and notify the engineer at least 24 hours prior to beginning
work.
10. The contractor shall set the grades for the tank and leach field prior to commencing
work to ensure gravity flow is acheived.
B. SEPTIC TANK
1. Septic tank shall be a Plastic or steel, 1250 GALLON tank capacity of MOA
approved construction. Installed to meet MOA and manufacturer requirements. Note
that conventional steel tanks are discouraged
2. A combination of soil and 4" minimum of insulation shall be placed over the tank, to
prevent ponding and promote drainage. The insulation shall be rated for burial and
meet moa requirements.
3. Tank shall be bedded per manufacturer recommendations.
C. DRAINFIELD
1. The Drainfield is to be located as shown on the site plan. Notify Engineer of any
changed site conditions.
2. The total depth of the initial drainfield excavation is to be at maximum 10' deep
Bottom of excavation shall be level +1- 1.5" max. If bedrock or inconsistent soils are
encountered, notify the engineer immediately.
3. In the event of over-excavation, a moa filter sand shall be used to maintain the
required depth.The top of the sand layer shall be level, plus or minus 0.5", and
raked, prior to placing sewer rock. Care shall be taken to not compact the sand.
4. A 48 inch effective layer of sewer rock is to be placed in the each trench. The 4"
effluent piping is to be buried within the gravel layer with 2" of sewer rock cover over
the piping.
5. The Distribution pipe shall be 4" perforated pvc pipe conforming to ASTM D3034.
6. The complete Drainfield gravel and piping is to be covered with a geotextile filter
fabric.
7. Soil or combination of soil and extruded board insulation to a depth of 3' or
equivalent is to be placed over the drainfield(s). Mounded side slopes shall not to
exceed 3:1. The minimum insulation thickness shall be 2". Insulation shall be moa
approved and rated for burial.
8. The septic tank and leachfield must not be closer than 100' to any existing private
well, or 200' to any public well.
9. The soils at this site may contain fines such as silt and clay. Rake sidewalls and
bottom of trench to remove any smears from excavation.
10. The old drain field shall be tied in with a bull run diverter valve.
idpality of Anchorage
�--tok- .,er and Wastewater
A
• + :•' •t•ECOMPLIANCE
Municipality of Anchorage ��� INE,§`, .4'•''N'.; et fuss. 11/28.
Development Services Department j*: 49TH ) .-.*fl,
•
On-Site Water and Wastewater Section . . .7. .
• /14700 Elmore St.
`}1 c--.-k...er
_ P.O.Box 196650 Anchorage,AK 99519-6650 , • :>1.
' ''g
. .
rii
Li www.munl.orq/onsite
/ CHARLES G BALZARIM
(907)343-7904 • ' •A/
ga<0,,•• CE-13854 • �A
1 F,9Fo • •.,,, *,.
Soils Log - Percolation Test 11 pROFESSIN�'
Performed For: WAYNE GRACEY Date Performed: 10/27/18
Legal Description: TROLL KNOLL BLOCK 1 LOT 2 Township, Range,Section:
Slope Site Plan
I
Depth
(Feet)
TOPSOIL
1
2-
SW,DENSE SAND WITH SOME
3- GRAVEL AND COBBLES
4-
5
i
6-
7-
8-
WAS GROUND WATER
9- ENCOUNTERED? NO
b
10- IF YES,AT WHAT DEPTH? NA
•
Depth to Water After ,�
F
11- Monitoring? None F
•
12- BOH Date: 11/5/18
13-
14- Reading Date Gross Time Net Time Depth to Water Net Drop
15- 1 10/27/18 3:24 0 2-0/16" 0"
16- 2 10/27/18 3:34 10 5-5/16" 3-5 16"
17- 3 10/27/18 3:35 0 2-0/16" 0"
18- "
4 10/27/18 3:45 10 5-4/16" 3-4/16"
19-
5 10/27/18 3:46 0 2-0/16" 0
20- 6 10/27/18 3:56 10 5-4/16" 3-4,11-3"
PERCOLATION RATE 3 (minutes:inch) PERC HOLE DIAMETER 6"
TEST RUN BETWEEN 3 FT AND 4 FT
COMMENTS LAST 6 READINGS SHOWN,PERFORMED FOR 1 HOUR.
PERFORMED BY: CHARLES BALZARINI I CHARLES BALZARINI CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10/27/18
r-N
•
.
•
• fiVj''' .
,0.1 ,ot. ,7 i
,V-61
. -
L
: i 00 ,,,,-77S --- • .oS 7
i
i
( /c' uni./ry
1/F.t-
vs
�, L o 7"3
r £CtT/�..., c,
LDi' Z ,�-
t�
;: ;, ,._,
I." -.
. N-t. ,.
LJ t.
7 57-eKs,
LoT / • :% .e.. ' , .
'.-, SGS 'r/e (!7%L/7 s✓ E-<1.`'c tegi/i'-
��
#14:4.0. P-.. fie ^ . & �..•Fp'r-'-
, '•—"-`---'--••-
s *49r 1<� 1.. ,• 'e
y' ° oo.e .t eats*
teti p, Gerald
Randa I Jr.
g'f % NO. 4053.5• • -
a
9F e .
NI,° °••.e•O- . ,t`
, ESSJONAL I l' :I
IT IS THE CONTRACTOR'S RESPONSIBILITY LEGEND: ��
LOT SURVEY CERTIFICATION: �
I HEREBY CERTIFY THAT I HAVE SURVEYED THE TO CHECK TOP OF FOUNDATION IN RELA• • 5/$REBAR RECOVERED
FfOPEr:T Y SHOWN AND DESCRIBED HEREON AND •
T 10N TO FINISH GRADE AND BUILDING o 5/8 REBAR SET THIS
THAT THE'IMPROVEMENTS SITUATED THEREON SET BACKS IN RELATION TO LOT LINES
ARE WITHIN THE PROPERTY LINES AND NO AND EASEMENTS. SVR��:Y
ENCROACHMENTS EXIST. 1 O 2.5(2"HVB& TACK SET
LEGAL DESCRIPTION: 0 EXISTING ELEVATIONS
Prepared by: GERALD V. RANDALL,JR. Reg. Land Surveyorr- > /.; DATUM ASSUMED
1135 WEST 8TH AVE., SUITE 5SCALE:
Prom; 279-7414
77,;-'6`zL ,K%1%L/[.G. ✓C3 ,,�r i
ANCHORAGE,ALASKA 99503 IJ
C&M ENGINEERING SERVICES
Ph: 907-854-5558
Municipality of Anchorage
Onsite Water & Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Proposed Septic System replacement for Troll Knoll Block 1 Lot 2
Dear Reviewer,
The above referenced property is currently served by an older, failing 4 bedroom septic system. The
owner would like to replace it with a new septic system.
We are proposing to install a new septic tank, and a new drain field. The old plastic tank will be inspected
and re-used or decommissioned per moa requirements.
Our review of available documentation and field investigation show that this project will not adversely
impact any nearby Wells, Wastewater disposal systems, replacement disposal sites, or drainage flowing
onto and off of the subject property.
The lot is served by a public well and the proposed septic system will be installed outside of the well’s
200’ protective radius.
Two Waivers are requested for this project:
1. The existing drain field appears to be 5’ from the home foundation at the closest point and
approximately 15’ of it is within 10’ of the foundation. The system has been in place since
1978 with no apparent ill effects to the home. Based on that, we believe this system should
be left in place as a reserve system. The requested distance is 5’.
2. The proposed drain field will be installed cross slope. The elevation difference is only 1’ so
the system may be easily installed in the soil strata. Due to the small elevation differential, we
are not preparing a cross section. We believe the waiver should be approved as approval will
have no discernable impact on the function of the system or on this or adjacent properties,
other than to place the drain field in a more desirable location for the owner. The finished
ground surface will be regraded upon completion of the system. The waiver is requested for
the system as shown on the plans.
Included with this letter is a permit application and design package, including plans, specifications, and
calculations. A test hole was excavated, however a deeper test hole will be excavated to 16’ deep during
construction to verify soil conditions and the groundwater table.
Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854-
5558 or by email cgbalzarini@gmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
11/07/18
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181401, Deb Wockenfuss, 11/28/18
Residence:
number of bedrooms 4 br
Water usage/bedroom 150 gpd/br
Water Usage 600 gpd
system type: CONVENTIONAL
type: SHALLOW
Application Rate 1.2 gpd/sqft
required absorption area 500 sqft
trench width (W) 5 ft
gravel depth (D) 4 ft below distribution pipe
Min Required Length: 50 ft
Total Excavation Depth: 10 ft
Cover: 3 ft
Insulation: 2" blueboard
Effluent Pipe:
Calc By: CGB Date: 10/30/2018
C&M ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
TROLL KNOLL B1 L2
RESIDENCE/LOT INFO
DRAINFIELD
4" ASTM 3034
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181401, Deb Wockenfuss, 11/28/18
10' UTILITY EASEMENT
10' UTI LITY
EAS
E
M
E
N
T
TROLL KNOLL BLOCK 1
LOT 2
NEW FCO
NEW 1250 GALLON TANK
OLD SUNSET TANK MAY
BE RE-USED IF IN GOOD
CONDITION. SEE TANK NOTE.
EXISTING DRAINFIELD
TO REMAIN
NEW 5x50x4' EFFECTIVE
DRAINFIELD
4 BR HOME
TH-1
TROLL KNOLL BLOCK 1
LOT 1(COMMUNITY WATER)
TROLL KNOLL BLOCK 1
LOT 3 (COMMUNITY WATER)
REA
SEPTIC AREA
GREATLAND ESTATES B1 L8 GREATLAND ESTATES B1 L7
WELL +200' FROM PROJECT
SL
O
P
E
1' CONTOURS
WATERLINE
SEPTIC
AREA
SEPTIC AREA
100' WELL RADIUS
LEPRECHAN
DRIVEWAY
BULL RUN DIVERTER
5'
5'
C&M ENGINEERING SERVICES
907-854-5558
SITE PLAN
LEGAL DESCRIPTION: TROLL KNOLL BLOCK 1 LOT 2
OWNER: WAYNE GRACEY DATE: 10/30/18 REV: 0 DRAWN: CB REF:
SCALE: 1" = 40'
CHARLES G BALZARINI
CE-13854R
EGISTEREDPROFESSIONALE NGINEER
LEGEND
CLEANOUT
MONITOR TUBE
TEST HOLE
SLOPE INDICATOR
NOTE:
1. THE PROPOSED SEPTIC SYSTEM IS
GREATER THAN:
100' FROM ANY PRIVATE WELLS
200' FROM ANY PUBLIC WELLS
100' FROM ANY SURFACE WATER
50' FROM ANY STEEP SLOPES
10' TO ANY PROPERTY LINE OR FOUNDATION
5' TO ANY TEST HOLES
EXCEPT WHERE SHOWN
0.5%
11/07/18
CONTRACTOR SHALL RE-CONFIGURE PLUMBING INSIDE CRAWL SPACE
TO EXIT THE FOUNDATION AS REQUIRED TO MEET GRADE REQUIREMENTS
.
IF PLUMBING CAN NOT BE RE-CONFIGURED, OR LINE GRADES CAN
NOT BE MAINTAINED, A LIFT STATION WILL BE REQUIRED.
FILL AND/OR INSULATION SHALL BE PLACED OVER ALL LINES.
TANK NOTE: TANK SHALL BE INSTALLED NO CLOSER
THAN 5' TO THE FOUNDATION. TOP OF TANK MAY BE
NO LOWER THAN BOTTOM OF FOOTING TO KEEP IT
OUTSIDE OF THE FOUNDATIONS BEARING PRISM.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181401, Deb Wockenfuss, 11/28/18
C&M ENGINEERING SERVICES
Ph: 907-854-5558
SPECIFICATIONS FOR ONSITE SEPTIC SYSTEM - MOA CERTIFIED INSTALLER
LEGAL: Troll Knoll Block 1 Lot 2
October, 2018
A. GENERAL
1. The septic design is for a 4 bedroom, single family residence only.
2. The site plan and drawings shall be a part of this specification.
3. The Wastewater system shall be installed by a certified installer in accordance All
materials and workmanship shall meet the Anchorage Department of Health and
State Department of Environmental Conservation requirements.
4. All soil tests are advisory to the design and are to be verified or modified in the field
by the engineer. The engineer shall perform percolation tests and groundwater
monitoring prior to finalizing design. An additional Test hole and percolation test is
required during construction.
5. All excavations and depths are advisory and are to be verified in the field by the
contractor to meet Municipality of Anchorage, Department of Environment of
Conservation requirements.
6. It is the responsibility of the owner to obtain all necessary permits or easements and
to locate any adjacent multi-family wells. A licensed surveyor should locate all
nearby lot lines, easements, exact 100’ radius from the neighboring on-site wells,
and any nearby surface water.
7. The excavation is to be exactly in the area shown on the site plan, any deviation
requires engineer approval.
8. Any remaining open test hole excavations shall be filled and monitor tube removed,
after construction of the Drainfield.
9. The contractor shall familiarize himself with the new code requirements for
inspection notification and notify the engineer at least 24 hours prior to beginning
work.
10. The contractor shall set the grades for the tank and leach field prior to commencing
work to ensure gravity flow is acheived.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181401, Deb Wockenfuss, 11/28/18
B. SEPTIC TANK
1. Septic tank shall be a Plastic or steel, 1250 GALLON tank capacity of MOA
approved construction. Installed to meet MOA and manufacturer requirements. Note
that conventional steel tanks are discouraged
2. A combination of soil and 4” minimum of insulation shall be placed over the tank, to
prevent ponding and promote drainage. The insulation shall be rated for burial and
meet moa requirements.
3. Tank shall be bedded per manufacturer recommendations.
C. DRAINFIELD
1. The Drainfield is to be located as shown on the site plan. Notify Engineer of any
changed site conditions.
2. The total depth of the initial drainfield excavation is to be at maximum 10’ deep
Bottom of excavation shall be level +/- 1.5” max. If bedrock or inconsistent soils are
encountered, notify the engineer immediately.
3. In the event of over-excavation, a moa filter sand shall be used to maintain the
required depth.The top of the sand layer shall be level, plus or minus 0.5”, and
raked, prior to placing sewer rock. Care shall be taken to not compact the sand.
4. A 48 inch effective layer of sewer rock is to be placed in the each trench. The 4”
effluent piping is to be buried within the gravel layer with 2” of sewer rock cover over
the piping.
5. The Distribution pipe shall be 4” perforated pvc pipe conforming to ASTM D3034.
6. The complete Drainfield gravel and piping is to be covered with a geotextile filter
fabric.
7. Soil or combination of soil and extruded board insulation to a depth of 3’ or
equivalent is to be placed over the drainfield(s). Mounded side slopes shall not to
exceed 3:1. The minimum insulation thickness shall be 2”. Insulation shall be moa
approved and rated for burial.
8. The septic tank and leachfield must not be closer than 100’ to any existing private
well, or 200’ to any public well.
9. The soils at this site may contain fines such as silt and clay. Rake sidewalls and
bottom of trench to remove any smears from excavation.
10. The old drain field shall be tied in with a bull run diverter valve.
CHARLES G BALZARINI
CE-13854R
EGISTEREDPROFESSIONALE NGINEER
10/29/18
WAYNE GRACEY
TROLL KNOLL BLOCK 1 LOT 2
10/27/18
NO
11/5/18
NA
10/27/181 3:24 0 2-0/16"
2 3:34 10 5-5/16"
3 3:35 0 2-0/16"
4 3:45 10 5-4/16"
5 3:46 0 2-0/16"
6 3:56 10 5-4/16"
TOPSOIL
SW, DENSE SAND WITH SOME
GRAVEL AND COBBLES
0"
3-5/16"
0"
3-4/16"
0"
3-4/16"
LAST 6 READINGS SHOWN, PERFORMED FOR 1 HOUR.
3 4
3
CHARLES BALZARINI CHARLES BALZARINI
10/27/18
BOH
6"
10/27/18
10/27/18
10/27/18
10/27/18
10/27/18
None
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP181401, Deb Wockenfuss, 11/28/18
t
r �
f `'J
/ lc' U77L./TS'
f €ir,Ll�i!%477�-
I 1 /-o7- z
1lg,x
L rJT` 3
OF
• t4
p, ;Gerald .Randall Jr. ; , r f r V
s
3f29 y}
LOT SURVEY CERTIFICATION.'
I HEREBY CERTIFY THAT I HAVE SURVEYED THE
P,gOPE11TY SHOLrN AND DESCRIBED HERFON AND
THAT THE IMPROVEMFNT5 SITUATED EHEREON
ARE WITHIN THE PROPERTY LINES ANO NO
ENCROACHMENTS EXIST.
Prepared by' GERALD V. RANDALL, JR. Reg. Land Surveyor
1135 WEST STH AVE.. SU17E 5
phone; 279.7414
ANCHORAGE, ALASKA 99543
- _-
IT IS THE CONTRACTOR'S RESPONSIBILITY
LL-GEND:
TO CHECK TOP OF FOUNUATiON IN RELA-
5/3 RE13AR RECOvFRE,
TION TO FINISH GRADE AND 61L)3Lf31NCi
a 5f8 REBAR SET THIS
SET BACKS IN RELATION TO LOT LINES
AND EASEMENTS,
SURVEY
C3 2'k2" HUR & TACK SET
L€C;tiL DESCRIPTION:
F?{tSTING CL€VATIPNI
• :�%fC i� FJ,i "` ` '. 1
6
DATUM ASSLLMIio
SCALE:
111
' MUNICIPALITY OF ANCHORAGE
?DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL DESCRIPTION
D UPGRADE
LOCATION ~ ~ ~ · x NO. OF I~EDROQMS
~- ~ ~f~turer ~ ~ M~ter,al ~quid capacity In gallons
~ OISTANCE TO: ~ e Foundation Nearest lot line PERMIT NO,
OTHER
PiPE MATERIALS
DATE LEGAL
PERMIT NO. ( 7810iA )
CBLKINS ENTERPRISES
LEPRBCHAUN CIRCLE
L2 Bi TROLL KNOLL S?D
RPPLICRNT
LOCRTION
LEGAL
825 'L' ~TREET~ ANCHORAGE~ AK ~501 ~ ~.~,~'
~4-4~0 / ~ .
ON--S I TE SEWER PERt1 I T ~ ~ II1~ - ID~'I~
LOT SIZE ~015~ SQUSRE FEET
TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH
MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING (SQ FT?BR)=
THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS:
DEPTH---- 10 LE~TH= ~4 GRAVEL DEPTH= 6
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD.
THE DEPTH OF 8 TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE
GROUND 8ND THE 'BOTTO~ OF THE EXCAVATION (IN FEET),
THERE IS NO SE~ WIDTH FOR TRENCHES.
THE GR~VEL DEPTH IS THE ~INIMUM DEPTH OF GRAVEL BETWEEN THE OUTFBLL PIPE
8ND THE BOTTO~OF THE EXCAVATION (IN FEET>,
PERMIT APPLICANT HAS THE RESPONSIBILI3Y TO INFORM THIS DEPARTMENT DURING THE
INSTRLLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY Ar.iD THE
NUMBER OF RESIDENCES THAT THE WELL WILL SERVE.
TWO (2 > INSPECT ION$ 8RE REQU I RED
BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS
DEPARTMENT WILL BE SUBJECT TO PROSECUTIOM.
MINIMUM DISTRIICE BETWEEN R WELL AND ANY ON-SITE SEWRGE DISPOSAL SYSTEM IS
100 FEET FOR A PRI¥BTE W£LL~ OR
150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL.
OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE
AVAILABLE TO INSURE PROPER INSTALLATION.
I CERTIFY THRT
l: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET
FORTH BY THE MUNICIPALITY OF ANCHORAGE.
2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES.
~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE
RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS.
ISSUED
~L~IC~ CALKINS ENTERPRISES
V~. 2
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
Pouch E~650, AnC~M~, AJasJ(a 99~02 276-222!
SOILS LOG -- PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
PERFORMED FOR: ~//~'//(/'~
DATE PERFORMED:
LEGAL DESCRIPTION:
~v/
m
SLOPE
\,
~ ~o-.q.U,
~,.o, ., ~
11 - ~.~ ~,. ' WAS GROUND WATER
· ENCOUNTERED?
12-:
..~. · IF YES. AT WHAT
o aP: DEPTH?
t~ - :.? :'o
_ -14 O.o' o*
,~e~.g:;y~ ~,~ ,~?~,~. Reading Date Time
SITE PLAN
i I io;~'
I
I
tEST-,
S
L
O
P
E
Net Depth to Net
Time Water Dro~
15-
O
16-
17-
18-
19-
20-
PERCOLATION RATE
(minutedlnch)
TEST RUN BETWEEN FT AND FT
PERFORMED BY: ~ ~ /~ CERTIFIED BY: ~O~N/~/~ --~y ~ DATE: /~ --//-- ~