Loading...
HomeMy WebLinkAboutTROLL KNOLL BLK 1 LT 2zt ioc • • oJNi�vAlil'y0a MUNICIPALITY OF ANCHORAGE z. On-Site Water&Wastewater Program PO Box 196650 4700 Elmore Road I. Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 http://www.muni.org/onsite 1)epartint'nt •VCH OR PGS On-Site Wastewater Disposal System Permit Permit Number: OSP181401 Effective Date: 11/28/2018 Work Type: Septic Upgrade Expiration Date: 11/28/2019 Tax Code Number: 05152114000 Site Legal Address: TROLL KNOLL BLK 1 LT 2 G:1360 Site Mailing Address: 20453 LEPRECHAN DR, Chugiak Owner: GRACEY WAYNE A Lot Size in Sq Ft: 30076 Design Engineer: C & M Engineering Total Bedrooms: 4 This permit is for the construction of: D Disposal Field 0 Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: ** The Engineer needs to do an additional test hole prior to the construction of the septic field to verify soils and the groundwater table.. Construction may proceed at your own risk before the 7 day water monitoring is complete. Please submit stamped and signed results with the As-built Inspection Report. If the results require a design change, construction of the system will stop pending On-Site review and approval. Received By: Date: I —//0//e Issued By: /6r,/ �,-> / Date: 872-g/0 / (( Municipality ®f Anchorage ``•.• „tTM•s , P.O. Box 196650 ® 4700 Elmore Road Anchorage, Alaska 99519-6650 a (907) 343-7904 ® Fax (907) 343-7997 http://www.muni.orq/Onsite Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV181097 COSA#: Permit#: OSP181401 PID#: 051-521-14 Legal Description: Troll Knoll B1 L2 Engineer: CM Engineering Applicant: Wayne Graces Your request for a waiver of the required 10 feet horizontal separation from the existing absorption field to the foundation has been approved. The approved separation distance is 5.0 feet. In addition,the proposed field does not follow the slope contours. See the approved design for the location. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. r Waiver is Granted: X Waiver is not Granted: Date: //Z-945/ Approved by: /fit/ / Name of Reviewer **** VARIANCE/WAIVER REVIEW **** °RUSH / EPLMJS MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On-Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTIC/WELL PERMIT APPLICATION Parcel I.D. 051 521 14 Property owner(s) Wayne Gracey Day phone bZS -2-1 `A Mailing address 20453 Leprechan Site address 20453 Leprechan Legal description (Sub'd., Block & Lot) Troll Knoll B1 L2 Legal description (Township, Range & Section) Lot Size 30,076 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field x Initial - Single Family (SF) ❑ (w/wo ADU) Septic Tank 0 Upgrade Duplex (D) Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy n (SF and/or D) Private Well ❑ Water Storage THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: none Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. Charles Balzarini, C&M Engineering (Signature of property owner or authorized agent) Permit/Rush Fees: 4 glo.tio Waiver Fees: . 3L{k Date of Payment: Date of Payment: 06/0 Receipt Number: 0 J6-gD Receipt Number: OI23°19 Permit No. 05P 171 t/O, Waiver No. 05 vi?31097 G:\Development Services\Building Safety\On Site Water and WastewaterlForms\Client Forms\Permit Application.doc Munidpality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE CONPUANCE OSP181401,Deb Vlhockenfuss, 11/281' C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water& Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Proposed Septic System replacement for Troll Knoll Block 1 Lot 2 Dear Reviewer, The above referenced property is currently served by an older, failing 4 bedroom septic system. The owner would like to replace it with a new septic system. We are proposing to install a new septic tank, and a new drain field. The old plastic tank will be inspected and re-used or decommissioned per moa requirements. Our review of available documentation and field investigation show that this project will not adversely impact any nearby Wells, Wastewaterdisposal systems, replacement disposal sites, ordrainage flowing onto and off of the subject property. The lot is served by a public well and the proposed septic system will be installed outside of the well's 200' protective radius. Two Waivers are requested for this project: 1. The existing drain field appears to be 5'from the home foundation at the closest point and approximately 15' of it is within 10' of the foundation. The system has been in place since 1978 with no apparent ill effects to the home. Based on that, we believe this system should be left in place as a reserve system. The requested distance is 5'. 2. The proposed drain field will be installed cross slope. The elevation difference is only 1' so the system may be easily installed in the soil strata. Due to the small elevation differential, we are not preparing a cross section. We believe the waiver should be approved as approval will have no discernable impact on the function of the system or on this or adjacent properties, other than to place the drain field in a more desirable location for the owner. The finished ground surface will be regraded upon completion of the system. The waiver is requested for the system as shown on the plans. Included with this letter is a permit application and design package, including plans, specifications, and calculations. A test hole was excavated, howevera deeper test hole will be excavated to 16' deep during construction to verify soil conditions and the groundwater table. Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854- 5558 or by email cqbalzariniqmail.com with any questions or concerns. Sincerely, Charles Balzarini, oF A:rarlet AL440 ,* “! m /\ 11/07/18 0 / // r� _ l F CHARLES G BALZARINI / 001f,- CE13854 ��� Ah-' p4O ESS',*..► Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPUANCI OSP181401,Deb lhWckenfuss. 11/28' C&M ENGINEERING SERVICES 907-854-5558 Septic Design Calculations Residence: TROLLKNOLLB1 L2 RESIDENCE/LOT INFO number of bedrooms 4 br Water usage/bedroom 150 gpd/br Water Usage 600 gpd DRAINFIELD system type: CONVENTIONAL type: SHALLOW Application Rate 1.2 gpd/sqft required absorption area 500 sqft trench width (W) 5 ft gravel depth (D) 4 ft below distribution pipe Min Required Length: 50 ft Total Excavation Depth: 10 ft Cover: 3 ft Insulation: 2" blueboard Effluent Pipe: 4" ASTM 3034 Calc By: CGB Date: 10/30/2018 °F AL.44. 4 g* /49 Ili •Nk * CHARLES G BALZARINI� ‹<% CE13854 �`� Aler c�sle �� O. ESS -' - xlicxdye TANK NOTE:TANK SHALL BE INSTALLED NO CLOSER •` pat%. • ewater THAN 5'TO THE FOUNDATION.TOP OF TANK MAY BE r fi NO LOWER THAN BOTTOM OF FOOTING TO KEEP IT DFOR ••i•.••. ANCE • OUTSIDE OF THE FOUNDATIONS BEARING PRISM. �C/owo.,oSP181401,.=Al - -..,-, tl12.3P. ./.� • • . ? -CHARLES G BALZARIM ° f<,*. CE-13854 ••`�/� IS �,o�- TROLL KNOLL BLOCK 1 lll�\N� ��`' � G�P� ����/ LOT 3 (COMMUNITY WATER) LEGEND 0 CLEANOUT NO / • MONITOR TUBE / EXISTING DRAINFIELD ® TEST HOLE TROLL KNOLL BLOCK 1 \ LOT 2 TO REMAIN 0.5% \SLOPE INDICATOR BULL RUN DIVERTER WATERLINE N NEW 1250 GALLON TANK OLD SUNSET TANK MAY \ BE RE-USED IF IN GOOD \, I CONDITION. SEE TANK NOTE. )•'' 'I� NE FCO 5r • \IVEWA 4 BR HOM 1' CONTOURS ®\ TH-1 SEPTIC AREA TROLL KNOLL BLOCK 1 NEW 5x50x4'EFFECTIVE DRAINFIELD LOT 1(COMMUNITY WATE• 10' UTILITY EASEMENT 100' WELL RADIUS GREATLAND ESTATES B1 L7 GREATLAND ESTATES B1 L8 SEPTIC WELL +200' FROM PROJECT / ` AREA ,.,„ SEPTIC AREA / NOTE: 1.THE PROPOSED SEPTIC SYSTEM IS GREATER THAN: CONTRACTOR SHALL RE-CONFIGURE PLUMBING INSIDE CRAWL SPACE 100' FROM ANY PRIVATE WELLS TO EXIT THE FOUNDATION AS REQUIRED TO MEET GRADE REQUIREMENTS 200'FROM ANY PUBLIC WELLS 100' FROM ANY SURFACE WATER IF PLUMBING CAN NOT BE RE-CONFIGURED,OR LINE GRADES CAN 50'FROM ANY STEEP SLOPES NOT BE MAINTAINED,A LIFT STATION WILL BE REQUIRED. 10'TO ANY PROPERTY LINE OR FOUNDATION 5'TO ANY TEST HOLES FILL AND/OR INSULATION SHALL BE PLACED OVERALL LINES. EXCEPT WHERE SHOWN t SCALE:1" =40' LEGAL DESCRIPTION:TROLL KNOLL BLOCK 1 LOT 2 C&M ENGINEERING SERV ICES OWNER:WAYNE GRACEY DATE: 10/30/18 REV: 0 I DRAWN: CB REF: 907-854-5558 SITE PLAN Municipality of Anchorage On-site water and wastewater REVIEWED FOR CODE CONPUANCE OSP181401,Deb Wockenfuss, 1//28/: CBM ENGINEERING SERVICES Ph: 907-8545558 SPECIFICATIONS FOR ONSITE SEPTIC SYSTEM - MOA CERTIFIED INSTALLER LEGAL: Troll Knoll Block 1 Lot 2 October, 2018 A. GENERAL 1. The septic design is for a 4 bedroom, single family residence only. 2. The site plan and drawings shall be a part of this specification. 3. The Wastewater system shall be installed by a certified installer in accordance All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. The engineer shall perform percolation tests and groundwater monitoring prior to finalizing design. An additional Test hole and percolation test is required during construction. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmentof Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. A licensed surveyor should locate all nearby lot lines, easements, exact 100' radius from the neighboring on-site wells, and any nearby surfacewater. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. Any remaining open test hole excavations shall be filled and monitor tube removed, after construction of the Drainfield. 9. The contractor shall familiarize himself with the new code requirements for inspection notification and notify the engineer at least 24 hours prior to beginning work. 10. The contractor shall set the grades for the tank and leach field prior to commencing work to ensure gravity flow is acheived. B. SEPTIC TANK 1. Septic tank shall be a Plastic or steel, 1250 GALLON tank capacity of MOA approved construction. Installed to meet MOA and manufacturer requirements. Note that conventional steel tanks are discouraged 2. A combination of soil and 4" minimum of insulation shall be placed over the tank, to prevent ponding and promote drainage. The insulation shall be rated for burial and meet moa requirements. 3. Tank shall be bedded per manufacturer recommendations. C. DRAINFIELD 1. The Drainfield is to be located as shown on the site plan. Notify Engineer of any changed site conditions. 2. The total depth of the initial drainfield excavation is to be at maximum 10' deep Bottom of excavation shall be level +1- 1.5" max. If bedrock or inconsistent soils are encountered, notify the engineer immediately. 3. In the event of over-excavation, a moa filter sand shall be used to maintain the required depth.The top of the sand layer shall be level, plus or minus 0.5", and raked, prior to placing sewer rock. Care shall be taken to not compact the sand. 4. A 48 inch effective layer of sewer rock is to be placed in the each trench. The 4" effluent piping is to be buried within the gravel layer with 2" of sewer rock cover over the piping. 5. The Distribution pipe shall be 4" perforated pvc pipe conforming to ASTM D3034. 6. The complete Drainfield gravel and piping is to be covered with a geotextile filter fabric. 7. Soil or combination of soil and extruded board insulation to a depth of 3' or equivalent is to be placed over the drainfield(s). Mounded side slopes shall not to exceed 3:1. The minimum insulation thickness shall be 2". Insulation shall be moa approved and rated for burial. 8. The septic tank and leachfield must not be closer than 100' to any existing private well, or 200' to any public well. 9. The soils at this site may contain fines such as silt and clay. Rake sidewalls and bottom of trench to remove any smears from excavation. 10. The old drain field shall be tied in with a bull run diverter valve. idpality of Anchorage �--tok- .,er and Wastewater A • + :•' •t•ECOMPLIANCE Municipality of Anchorage ��� INE,§`, .4'•''N'.; et fuss. 11/28. Development Services Department j*: 49TH ) .-.*fl, • On-Site Water and Wastewater Section . . .7. . • /14700 Elmore St. `}1 c--.-k...er _ P.O.Box 196650 Anchorage,AK 99519-6650 , • :>1. ' ''g . . rii Li www.munl.orq/onsite / CHARLES G BALZARIM (907)343-7904 • ' •A/ ga<0,,•• CE-13854 • �A 1 F,9Fo • •.,,, *,. Soils Log - Percolation Test 11 pROFESSIN�' Performed For: WAYNE GRACEY Date Performed: 10/27/18 Legal Description: TROLL KNOLL BLOCK 1 LOT 2 Township, Range,Section: Slope Site Plan I Depth (Feet) TOPSOIL 1 2- SW,DENSE SAND WITH SOME 3- GRAVEL AND COBBLES 4- 5 i 6- 7- 8- WAS GROUND WATER 9- ENCOUNTERED? NO b 10- IF YES,AT WHAT DEPTH? NA • Depth to Water After ,� F 11- Monitoring? None F • 12- BOH Date: 11/5/18 13- 14- Reading Date Gross Time Net Time Depth to Water Net Drop 15- 1 10/27/18 3:24 0 2-0/16" 0" 16- 2 10/27/18 3:34 10 5-5/16" 3-5 16" 17- 3 10/27/18 3:35 0 2-0/16" 0" 18- " 4 10/27/18 3:45 10 5-4/16" 3-4/16" 19- 5 10/27/18 3:46 0 2-0/16" 0 20- 6 10/27/18 3:56 10 5-4/16" 3-4,11-3" PERCOLATION RATE 3 (minutes:inch) PERC HOLE DIAMETER 6" TEST RUN BETWEEN 3 FT AND 4 FT COMMENTS LAST 6 READINGS SHOWN,PERFORMED FOR 1 HOUR. PERFORMED BY: CHARLES BALZARINI I CHARLES BALZARINI CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 10/27/18 r-N • . • • fiVj''' . ,0.1 ,ot. ,7 i ,V-61 . - L : i 00 ,,,,-77S --- • .oS 7 i i ( /c' uni./ry 1/F.t- vs �, L o 7"3 r £CtT/�..., c, LDi' Z ,�- t� ;: ;, ,._, I." -. . N-t. ,. LJ t. 7 57-eKs, LoT / • :% .e.. ' , . '.-, SGS 'r/e (!7%L/7 s✓ E-<1.`'c tegi/i'- �� #14:4.0. P-.. fie ^ . & �..•Fp'r-'- , '•—"-`---'--••- s *49r 1<� 1.. ,• 'e y' ° oo.e .t eats* teti p, Gerald Randa I Jr. g'f % NO. 4053.5• • - a 9F e . NI,° °••.e•O- . ,t` , ESSJONAL I l' :I IT IS THE CONTRACTOR'S RESPONSIBILITY LEGEND: �� LOT SURVEY CERTIFICATION: � I HEREBY CERTIFY THAT I HAVE SURVEYED THE TO CHECK TOP OF FOUNDATION IN RELA• • 5/$REBAR RECOVERED FfOPEr:T Y SHOWN AND DESCRIBED HEREON AND • T 10N TO FINISH GRADE AND BUILDING o 5/8 REBAR SET THIS THAT THE'IMPROVEMENTS SITUATED THEREON SET BACKS IN RELATION TO LOT LINES ARE WITHIN THE PROPERTY LINES AND NO AND EASEMENTS. SVR��:Y ENCROACHMENTS EXIST. 1 O 2.5(2"HVB& TACK SET LEGAL DESCRIPTION: 0 EXISTING ELEVATIONS Prepared by: GERALD V. RANDALL,JR. Reg. Land Surveyorr- > /.; DATUM ASSUMED 1135 WEST 8TH AVE., SUITE 5SCALE: Prom; 279-7414 77,;-'6`zL ,K%1%L/[.G. ✓C3 ,,�r i ANCHORAGE,ALASKA 99503 IJ C&M ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water & Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Proposed Septic System replacement for Troll Knoll Block 1 Lot 2 Dear Reviewer, The above referenced property is currently served by an older, failing 4 bedroom septic system. The owner would like to replace it with a new septic system. We are proposing to install a new septic tank, and a new drain field. The old plastic tank will be inspected and re-used or decommissioned per moa requirements. Our review of available documentation and field investigation show that this project will not adversely impact any nearby Wells, Wastewater disposal systems, replacement disposal sites, or drainage flowing onto and off of the subject property. The lot is served by a public well and the proposed septic system will be installed outside of the well’s 200’ protective radius. Two Waivers are requested for this project: 1. The existing drain field appears to be 5’ from the home foundation at the closest point and approximately 15’ of it is within 10’ of the foundation. The system has been in place since 1978 with no apparent ill effects to the home. Based on that, we believe this system should be left in place as a reserve system. The requested distance is 5’. 2. The proposed drain field will be installed cross slope. The elevation difference is only 1’ so the system may be easily installed in the soil strata. Due to the small elevation differential, we are not preparing a cross section. We believe the waiver should be approved as approval will have no discernable impact on the function of the system or on this or adjacent properties, other than to place the drain field in a more desirable location for the owner. The finished ground surface will be regraded upon completion of the system. The waiver is requested for the system as shown on the plans. Included with this letter is a permit application and design package, including plans, specifications, and calculations. A test hole was excavated, however a deeper test hole will be excavated to 16’ deep during construction to verify soil conditions and the groundwater table. Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854- 5558 or by email cgbalzarini@gmail.com with any questions or concerns. Sincerely, Charles Balzarini, PE 11/07/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181401, Deb Wockenfuss, 11/28/18 Residence: number of bedrooms 4 br Water usage/bedroom 150 gpd/br Water Usage 600 gpd system type: CONVENTIONAL type: SHALLOW Application Rate 1.2 gpd/sqft required absorption area 500 sqft trench width (W) 5 ft gravel depth (D) 4 ft below distribution pipe Min Required Length: 50 ft Total Excavation Depth: 10 ft Cover: 3 ft Insulation: 2" blueboard Effluent Pipe: Calc By: CGB Date: 10/30/2018 C&M ENGINEERING SERVICES 907-854-5558 Septic Design Calculations TROLL KNOLL B1 L2 RESIDENCE/LOT INFO DRAINFIELD 4" ASTM 3034 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181401, Deb Wockenfuss, 11/28/18 10' UTILITY EASEMENT 10' UTI LITY EAS E M E N T TROLL KNOLL BLOCK 1 LOT 2 NEW FCO NEW 1250 GALLON TANK OLD SUNSET TANK MAY BE RE-USED IF IN GOOD CONDITION. SEE TANK NOTE. EXISTING DRAINFIELD TO REMAIN NEW 5x50x4' EFFECTIVE DRAINFIELD 4 BR HOME TH-1 TROLL KNOLL BLOCK 1 LOT 1(COMMUNITY WATER) TROLL KNOLL BLOCK 1 LOT 3 (COMMUNITY WATER) REA SEPTIC AREA GREATLAND ESTATES B1 L8 GREATLAND ESTATES B1 L7 WELL +200' FROM PROJECT SL O P E 1' CONTOURS WATERLINE SEPTIC AREA SEPTIC AREA 100' WELL RADIUS LEPRECHAN DRIVEWAY BULL RUN DIVERTER 5' 5' C&M ENGINEERING SERVICES 907-854-5558 SITE PLAN LEGAL DESCRIPTION: TROLL KNOLL BLOCK 1 LOT 2 OWNER: WAYNE GRACEY DATE: 10/30/18 REV: 0 DRAWN: CB REF: SCALE: 1" = 40' CHARLES G BALZARINI CE-13854R EGISTEREDPROFESSIONALE NGINEER LEGEND CLEANOUT MONITOR TUBE TEST HOLE SLOPE INDICATOR NOTE: 1. THE PROPOSED SEPTIC SYSTEM IS GREATER THAN: 100' FROM ANY PRIVATE WELLS 200' FROM ANY PUBLIC WELLS 100' FROM ANY SURFACE WATER 50' FROM ANY STEEP SLOPES 10' TO ANY PROPERTY LINE OR FOUNDATION 5' TO ANY TEST HOLES EXCEPT WHERE SHOWN 0.5% 11/07/18 CONTRACTOR SHALL RE-CONFIGURE PLUMBING INSIDE CRAWL SPACE TO EXIT THE FOUNDATION AS REQUIRED TO MEET GRADE REQUIREMENTS . IF PLUMBING CAN NOT BE RE-CONFIGURED, OR LINE GRADES CAN NOT BE MAINTAINED, A LIFT STATION WILL BE REQUIRED. FILL AND/OR INSULATION SHALL BE PLACED OVER ALL LINES. TANK NOTE: TANK SHALL BE INSTALLED NO CLOSER THAN 5' TO THE FOUNDATION. TOP OF TANK MAY BE NO LOWER THAN BOTTOM OF FOOTING TO KEEP IT OUTSIDE OF THE FOUNDATIONS BEARING PRISM. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181401, Deb Wockenfuss, 11/28/18 C&M ENGINEERING SERVICES Ph: 907-854-5558 SPECIFICATIONS FOR ONSITE SEPTIC SYSTEM - MOA CERTIFIED INSTALLER LEGAL: Troll Knoll Block 1 Lot 2 October, 2018 A. GENERAL 1. The septic design is for a 4 bedroom, single family residence only. 2. The site plan and drawings shall be a part of this specification. 3. The Wastewater system shall be installed by a certified installer in accordance All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. The engineer shall perform percolation tests and groundwater monitoring prior to finalizing design. An additional Test hole and percolation test is required during construction. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environment of Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. A licensed surveyor should locate all nearby lot lines, easements, exact 100’ radius from the neighboring on-site wells, and any nearby surface water. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. Any remaining open test hole excavations shall be filled and monitor tube removed, after construction of the Drainfield. 9. The contractor shall familiarize himself with the new code requirements for inspection notification and notify the engineer at least 24 hours prior to beginning work. 10. The contractor shall set the grades for the tank and leach field prior to commencing work to ensure gravity flow is acheived. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181401, Deb Wockenfuss, 11/28/18 B. SEPTIC TANK 1. Septic tank shall be a Plastic or steel, 1250 GALLON tank capacity of MOA approved construction. Installed to meet MOA and manufacturer requirements. Note that conventional steel tanks are discouraged 2. A combination of soil and 4” minimum of insulation shall be placed over the tank, to prevent ponding and promote drainage. The insulation shall be rated for burial and meet moa requirements. 3. Tank shall be bedded per manufacturer recommendations. C. DRAINFIELD 1. The Drainfield is to be located as shown on the site plan. Notify Engineer of any changed site conditions. 2. The total depth of the initial drainfield excavation is to be at maximum 10’ deep Bottom of excavation shall be level +/- 1.5” max. If bedrock or inconsistent soils are encountered, notify the engineer immediately. 3. In the event of over-excavation, a moa filter sand shall be used to maintain the required depth.The top of the sand layer shall be level, plus or minus 0.5”, and raked, prior to placing sewer rock. Care shall be taken to not compact the sand. 4. A 48 inch effective layer of sewer rock is to be placed in the each trench. The 4” effluent piping is to be buried within the gravel layer with 2” of sewer rock cover over the piping. 5. The Distribution pipe shall be 4” perforated pvc pipe conforming to ASTM D3034. 6. The complete Drainfield gravel and piping is to be covered with a geotextile filter fabric. 7. Soil or combination of soil and extruded board insulation to a depth of 3’ or equivalent is to be placed over the drainfield(s). Mounded side slopes shall not to exceed 3:1. The minimum insulation thickness shall be 2”. Insulation shall be moa approved and rated for burial. 8. The septic tank and leachfield must not be closer than 100’ to any existing private well, or 200’ to any public well. 9. The soils at this site may contain fines such as silt and clay. Rake sidewalls and bottom of trench to remove any smears from excavation. 10. The old drain field shall be tied in with a bull run diverter valve. CHARLES G BALZARINI CE-13854R EGISTEREDPROFESSIONALE NGINEER 10/29/18 WAYNE GRACEY TROLL KNOLL BLOCK 1 LOT 2 10/27/18 NO 11/5/18 NA 10/27/181 3:24 0 2-0/16" 2 3:34 10 5-5/16" 3 3:35 0 2-0/16" 4 3:45 10 5-4/16" 5 3:46 0 2-0/16" 6 3:56 10 5-4/16" TOPSOIL SW, DENSE SAND WITH SOME GRAVEL AND COBBLES 0" 3-5/16" 0" 3-4/16" 0" 3-4/16" LAST 6 READINGS SHOWN, PERFORMED FOR 1 HOUR. 3 4 3 CHARLES BALZARINI CHARLES BALZARINI 10/27/18 BOH 6" 10/27/18 10/27/18 10/27/18 10/27/18 10/27/18 None Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP181401, Deb Wockenfuss, 11/28/18 t r � f `'J / lc' U77L./TS' f €ir,Ll�i!%477�- I 1 /-o7- z 1lg,x L rJT` 3 OF • t4 p, ;Gerald .Randall Jr. ; , r f r V s 3f29 y} LOT SURVEY CERTIFICATION.' I HEREBY CERTIFY THAT I HAVE SURVEYED THE P,gOPE11TY SHOLrN AND DESCRIBED HERFON AND THAT THE IMPROVEMFNT5 SITUATED EHEREON ARE WITHIN THE PROPERTY LINES ANO NO ENCROACHMENTS EXIST. Prepared by' GERALD V. RANDALL, JR. Reg. Land Surveyor 1135 WEST STH AVE.. SU17E 5 phone; 279.7414 ANCHORAGE, ALASKA 99543 - _- IT IS THE CONTRACTOR'S RESPONSIBILITY LL-GEND: TO CHECK TOP OF FOUNUATiON IN RELA- 5/3 RE13AR RECOvFRE, TION TO FINISH GRADE AND 61L)3Lf31NCi a 5f8 REBAR SET THIS SET BACKS IN RELATION TO LOT LINES AND EASEMENTS, SURVEY C3 2'k2" HUR & TACK SET L€C;tiL DESCRIPTION: F?{tSTING CL€VATIPNI • :�%fC i� FJ,i "` ` '. 1 6 DATUM ASSLLMIio SCALE: 111 ' MUNICIPALITY OF ANCHORAGE ?DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL DESCRIPTION D UPGRADE LOCATION ~ ~ ~ · x NO. OF I~EDROQMS ~- ~ ~f~turer ~ ~ M~ter,al ~quid capacity In gallons ~ OISTANCE TO: ~ e Foundation Nearest lot line PERMIT NO, OTHER PiPE MATERIALS DATE LEGAL PERMIT NO. ( 7810iA ) CBLKINS ENTERPRISES LEPRBCHAUN CIRCLE L2 Bi TROLL KNOLL S?D RPPLICRNT LOCRTION LEGAL 825 'L' ~TREET~ ANCHORAGE~ AK ~501 ~ ~.~,~' ~4-4~0 / ~ . ON--S I TE SEWER PERt1 I T ~ ~ II1~ - ID~'I~ LOT SIZE ~015~ SQUSRE FEET TYPE OF SOIL ABSORBTION SYSTEM IS: TRENCH MAXIMUM NUMBER OF BEDROOMS = 4 SOIL RATING (SQ FT?BR)= THE REQUIRED SIZE OF THE SOIL ABSORPTION SYSTEM IS: DEPTH---- 10 LE~TH= ~4 GRAVEL DEPTH= 6 THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRAINFIELD. THE DEPTH OF 8 TRENCH OR PIT IS THE DISTANCE BETWEEN THE SURFACE OF THE GROUND 8ND THE 'BOTTO~ OF THE EXCAVATION (IN FEET), THERE IS NO SE~ WIDTH FOR TRENCHES. THE GR~VEL DEPTH IS THE ~INIMUM DEPTH OF GRAVEL BETWEEN THE OUTFBLL PIPE 8ND THE BOTTO~OF THE EXCAVATION (IN FEET>, PERMIT APPLICANT HAS THE RESPONSIBILI3Y TO INFORM THIS DEPARTMENT DURING THE INSTRLLATION INSPECTIONS OF ANY WELLS ADJACENT TO THIS PROPERTY Ar.iD THE NUMBER OF RESIDENCES THAT THE WELL WILL SERVE. TWO (2 > INSPECT ION$ 8RE REQU I RED BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION AND APPROVAL BY THIS DEPARTMENT WILL BE SUBJECT TO PROSECUTIOM. MINIMUM DISTRIICE BETWEEN R WELL AND ANY ON-SITE SEWRGE DISPOSAL SYSTEM IS 100 FEET FOR A PRI¥BTE W£LL~ OR 150 TO 200 FEET FROM 8 PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. I CERTIFY THRT l: I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. ~: I UNDERSTAND THAT THE ON-SITE SEWER SYSTEM MAY REQUIRE ENLARGEMENT IF THE RESIDENCE IS REMODELED TO INCLUDE MORE THAN 4 BEDROOMS. ISSUED ~L~IC~ CALKINS ENTERPRISES V~. 2 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION Pouch E~650, AnC~M~, AJasJ(a 99~02 276-222! SOILS LOG -- PERCOLATION TEST SOILS LOG PERCOLATION TEST PERFORMED FOR: ~//~'//(/'~ DATE PERFORMED: LEGAL DESCRIPTION: ~v/ m SLOPE \, ~ ~o-.q.U, ~,.o, ., ~ 11 - ~.~ ~,. ' WAS GROUND WATER · ENCOUNTERED? 12-: ..~. · IF YES. AT WHAT o aP: DEPTH? t~ - :.? :'o _ -14 O.o' o* ,~e~.g:;y~ ~,~ ,~?~,~. Reading Date Time SITE PLAN i I io;~' I I tEST-, S L O P E Net Depth to Net Time Water Dro~ 15- O 16- 17- 18- 19- 20- PERCOLATION RATE (minutedlnch) TEST RUN BETWEEN FT AND FT PERFORMED BY: ~ ~ /~ CERTIFIED BY: ~O~N/~/~ --~y ~ DATE: /~ --//-- ~ 72.o0e (7/76) o ,,,4