HomeMy WebLinkAboutTONJESS ESTATES BLK 3 LT 12Onsite File
Tonjess
Estates
Block 3
Lot 12
#051-532-04
Municipality of Anchorage
On-Site Water and Wastewater Section - (907) 343-7904 Page 1 of 1
ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP 171364 PID Number: 051 532 04
Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New ❑t Upgrade
Name
Williamson
ABSORPTION FIELD
❑ Deep Trench ❑■ Wide Trench ❑ Bed ❑ Mound
Site Address
21531 Tony Cir
❑ Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
4
6 GPD/SFJ
5.9 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
3.8 Ft.
Gravel depth beneath pipe
2.1 Ft.
Subdivision Block Lot
Tonjess Estates B3 L12
Fill added above original grade
0.2+/- Ft.
Gravel length
2O Ft.
Township Range Section
Gravel width
5 Ft.
Beds: Number of Lines
-
Distance between lines
- Ft.
SEPARATION DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between trenches
From
Tank
Field
Tank
Line
143 Ft2
1
-Ft.
Well
+50
.+.50
-
_
+25
TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑■ Other
Manufacturer
Orenco
Capacity
1500 Gal.
Surface Water
+50
+50
-
_
Material
Number of compartments
Lot Line
+10
2
-
-
NA
fiberglass
2
Foundation
+10
+10-
_
_
LIFT STATION
Manufacturer
Capacity
Remarks old tank demolished per code
na
na Gal.
advantex system
Alarm location
na
Electrical installed by
na
Installer
PIPE MATERIAL House to tank 30034 Tankto
3034
Guaranteed Services
Drainfield 3034 CO/MT3034
Inspector CHARLES BALZARINI
BENCH MARK (Assumed elevation) 94.23 ft
Inspdection 1st 12/14/17 2n 12/18/17
Location and description
3`" 4th
advantex lid
ON-SITE WATER AND WASTEWATER SECTION APPROVAL
Engineer's Stamp
�� �� a`�tS,
Conditional Approval: Date
Awl
low
HARLES
Septic System
Approved
G BALZARIC. %
�`���sT cE-13854
Date j Jr
•.��,���
PROFES510NP�SSO
Note: this approval does not include well permit requirements.
�>>
tnev uoivu_ia)
2/17/19
CHARLES G BALZARINI
CE-13854R
E
G
ISTEREDPROFE S S I O N A LENGINEER8/8/18
MUNICIPALITY OF ANCHORAGE raenr
iN On-Site Water&Wastewater Program 1p S;; i Z'18 t�
PO Box 196650 4700 Elmore Road '...
• Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 esOM
http:/Iwww.muni.orglonsite
Dcpartnl nt
On-Site Wastewater Disposal System Permit
Permit Number: OSP171364 Effective Date: 12/13/2017
Work Type: Septic Upgrade Expiration Date: 12/13/2018
Tax Code Number: 05153204000
Site Legal Address: TONJESS ESTATES BLK 3 LT 12 G:1462
Site Mailing Address: 21531 TONY CIR, Chugiak
Owner: WILLIAMSON JOHN P & KATHRYN A Lot Size in Sq Ft: 47753
Design Engineer: Total Bedrooms: 4
This permit is for the construction of:
Q Disposal Field Q Septic Tank 0 Holding Tank 0 Privy 0 Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Receiv-. By: Date: ( )`4,7/
/
� y l 7
Issued By: n L� � Date: /7i �
punt
Municipality of Anchorage
I tpartment
P.O. Box 196650 • 4700 Elmore Road
Anchorage, Alaska 99519-6650 • (907) 343-7904 • Fax (907) 343-7997
http://www.rnuni.orq/Onsite
Development Services Division
On-Site Water and Wastewater Program
**** VARIANCE/WAIVER REVIEW ****
Waiver#: OSV171153 COSA#: Permit#: OSP171364
PID#: 051-632-04
Legal Description: Tonless Estates B3 L12
Engineer: CM Engineering
Applicant: John Williamson
The following waivers have been approved:
• Proposed absorption field to property line -2 feet
• Proposed absorption field to neighbors well - 90 feet
• Proposed tank to well on property - 96 feet
• Proposed field to existing field - 10 feet
• Existing field to neighbors field - 12 feet
Future upgrades to the on-site wastewater disposal system will require all separation distances be
met or another approval from this department.
® The affected adjacent property owner(s) have been given a 7 day notice regarding this
waiver.
® Notarized letter(s) of nonobjection have been received from the owner(s) of the affected
adjacent property.
❑ Adjacent properties are not affected by this waiver.
Waiver is Granted: X Waiver is not Granted:
Date: /2-7/V7/7 Approved by: kkif-- -)0-r �
Name of Review-
**** VARIANCE/WAIVER REVIEW ****
MUNICIPALITY OF ANCHORAGE
tv.,
Community Development Department r,9r Phoned-907-343-7904
Development Services Division Fa`x: 90 997
On-Site Water &Wastewater Program
�i Dl
ON-SITE SEWER/ ELL PERMIT APPLICATION
/c,Parcel I.D. ) 3 Z _c�y `� 5 c3 yn
Property owner(s) -301-Cir+ )c4 Tf)Y W-TGL K11 SO4'' Day phone 5.2.6 ^ to( ,3
Mailing address PO c ?c 6 7f q°71
Site address 0) S 3 I --1-04/1 (}t
Legal description (Sub'd., Block & Lot) 70A/.7E s5 E 5 T 3
Legal description (Township, Range & Section)
Lot Size 47r 75. ) Sq. Ft. Number of Bedrooms vl
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field Initial ❑ Single Family (SF) Al
(w/iaet AD U)
Septic Tank Upgrade
Duplex (D) ❑
Holding Tank ❑ Renewal ❑
Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR:
LvaL To 55P7 C1 SES 144PM- Tl vL Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(S natu - a property owner or authorized agent)
Permit/Rush Fees: Waiver Fees: 215 cr 13
Date of Payment: aJ(o I i' Date of Payment: 127/i/7I Z/)V/7
Receipt Number: 00.33a1D Receipt Number: 01034D 0371 P
Permit No. OSP1713L4 Waiver No. 05V 17/f 5 ,
Permit App_9-1-12.doc
C&M ENGINEERING SERVICES
Ph:907-8545558
Municipality of Anchorage
Onsite Water&Wastewater Program
4700 Elmore Rd Anchorage, Ak 99507
RE: Tonjess Estates Block 3 Lot 12
Dear Reviewer,
We are requesting approval to install a new 4 bedroom septic system at the above referenced property.
The property is currently developed, and the existing tank has failed and the leachfield is surcharged.
Due to the local well configuration, steep slopes, and available space, we are requesting approval to
install an Advantex system and new leachfield on the lot. The proposed system will require the approval
of waivers.
Waiver#1.We are requesting a lot line waiver to the leachfield. The requested waiver distance is 2'. We
believe the waiver is justified due to the limited space of the lot and lack of available options. The impact
to the neighboring lot is minimal. The neighboring lot has sufficient space to for a replacement system 10'
or more from the proposed system.
Waiver#2.We are requesting a leachfield to neighboring well waiver of 90'. We believe the use of an
advantex system mitigates concerns of contaminating the neighboring well. The required maintenance
agreement with remote monitoring reduces the risk of effluent contaminating the well.
Waiver#3.We are requesting a septic tank to well waiver of 96' between the new tank and the existing
well on this property. We believe the waiver will not excessively impact this or the neighboring property.
The resilience of the advantex tanks and the required maintenance contract, including remote monitoring,
reduce the risk of contamination to the well.
Waiver#4. A waiver may be necessary between the new proposed leachfield, and the existing deep
trench. The existing system was reportedly installed as a deep trench with an effective depth of 7' so the
required separation is 14'. During inspection, it was noted that the deep trench system measures only 3'
effective in the sump, but it may be plugged. We are requesting that the separation distance be waived to
cp 10'. This waiver is justified due to the free draining nature of the soils and the use of AWTS. i81�AZ'J2ou,
vgyr
TilE 6KJVJ- j& CLt7 7e ,/cW
(�H30l�r;vC� F��-i t) 5EP4fzAi j — wtP,45c..gfs IZ
� 6 r�i= RE ca vee x,✓to 4 w 2-vE R t-o,ZT-H.4S e� .ti
Installation of the proposed system will not negatively impact this or adjacent lots, due to the relatively
large lot size, and the fact that the advantex system produces relatively clean effluent.
Included with this letter is a permit application, plans, specifications, and calculations. A testhole was
excavated on this lot and shows relatively free draining soils and no impermeable layers or groundwater
to a depth greater than 12'.
Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854-
5558 or by email cgbalzarini(a)gmail.com with any questions or concerns.
Sincerely,
Charles Balzarini, PE
.sf.l
EXISTING /4'.4C:.'
�• ' " •9 6
LOT 13 WELL TM �� �*��
(
90' RADIUS •• ••••• ••••
FOR REFERENCE
0 •••
100' NEIGHBORING rj HARLES G BALZARII
WELL RADIUS I FF,••. CE-13854, �,A/
NEW 5'x20' DRAINFIELD �ll�FgFo•1-13 ��AMY
\ — 2' EFFECTIVE l�\ROFES``P ~
/ \ o
v\ \ \9 / /$i?7
/ v�tiM
NEIGHBORING
EXISTING TESTHOLE 2' Gc air SEPTIC AREA
�0 5' DEEP, UN-USED �C. L TOE OF
� •� �' °�9 , STEEP
\ OPTIONAL TH_1 j SLOPE
TONY x DIVERTER TO CONNECT • EXISTING DRAINFIELD
CIRCLE TO EXIST TRENCH `�" �; 'c TO BE RESERVE SITE.
o I/�4' -1,_,�s� ONLY 3' EFFECTIVE
\ _ �� ® `! ° MEASURED IN SUMP.
` 0\ \ 10 2' NEW 1500 GAL
96' MIN ADVANTEX TANK IN/ AX-
, [J
POD
\`S� CRUSH AND PROPERLY
3 BR DISPOSE OF EXISTING
HOME TANK
v‘10DRIVEWAY
100'
�6) NOTE: SYSTEM WELL RADIUS
SIZED FOR 4
NBEDROOMS i
' XISTING
�OELL \ ,i,,
sy
°
J,,s9
/
/
LOT 12 \_,
II
APPROX /
EXISTING /
WELL / /
LEGEND NOTES:
o CLEANOUT — —. �/ 1. THE PROPOSED SEPTIC SYSTEM IS GREATER THAN:
• MONITOR TUBE 100' FROM ANY PRIVATE WELLS( EXCEPT FOR WAIVER)
200' FROM ANY PUBLIC WELLS
® TEST HOLE 100' FROM ANY SURFACE WATER
50' FROM ANY STEEP SLOPES
0.5%\ SLOPE INDICATOR 10' TO ANY PROPERTY LINE OR FOUNDATION( EXCEPT FOR WAIVER)
/ 5' TO ANY TEST HOLES
SCALE: 1" = 30'
LEGAL DESCRIPTION: TONJESS ESTATES BLOCK 3 LOT 12
C&M ENGINEERING SERVICES OWNER: JOHN AND KATHY DATE:11/30/17 REV:O DRAWN: CB REF:
907-854-5558 WILLIAMSON
SITE PLAN
CBM ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
Residence: TONJESS EST B3 L 12
RESIDENCE/LOT INFO
number of bedrooms 4 br
Water usage/bedroom 150 gpd/br
Water Usage 600 gpd
TANK
Tank Size 1500 gal, min
Filter Pod (1)AX-20
DRAINFIELD
system type: advantex
type: shallow trench
Application Rate 6 gpd/sqft
required absorption area 100 sqft
trench width (W) 5 ft
gravel depth (D) ,3''a ft below distribution pipe
Shallow trench factor 5080.1 (W+2)/(W+1+2D)
ogee (12.11%)11)
(Shallow trench factor* Required
Min Required Length: H ft absorption area 1W)
Total Depth: 6 ft
Cover: 2 ft min
Insulation: 2" blueboard
Use Length: 20 ft ok
Effluent Pipe: 4"ASTM 3034. perfrorated
41S F \1
A:rkP�.••. •*'•''0
a • �I A' ••� +l
i*:•
4912 1" *�0
.& 'wrrHEW P.BALZARIN: j
/�+,'� •. No.CE118893. �
C&M ENGINEERING SERVICES
907-854-5558
Septic Design Calculations
Residence: TONJESS EST B3 L 12
RESIDENCE/LOT INFO
number of bedrooms 4 br
Water usage/bedroom 150 gpd/br
Water Usage 600 gpd
TANK
Tank Size 1500 gal, min
Filter Pod (1)AX-20
RESERVE DRAIN FIELD
system type: advantex
type: existing deep trench
Application Rate 6 gpd/sqft
required absorption area 100 sqft
trench width (W) 3 ft
gravel depth (D) 3 ft verified below distribution pipe
Min Required Length: 11.1111111 ft (Shallow trench factor * Required
absorption area/W)
Cover: 3 ft plus
The existing trench is 27' long, with a measured effective depth of 3' in the sump.
Existing trench is suitable for a alternate/reserve site.
(`✓ A
.; T!; A .''�
. 9 /.....`%..+
�?. ♦ ( Jf/
eit
C&M ENGINEERING SERVICES 3tgm %\ '9 rr,
907-854-5558 elf ���" 0
TESTHOLE #1 �F,.ARLES
%13854
-1 8�LZARiw j
Soils Log - Percolation Test +liF,pii.vaQo,?,, ,;
WILLIAMSON ll� ROFESS� 1•�
Performed For: ������-
Legal Description: TONJESS ESTATES BLOCK 3 LOT 12 Date Performed: 11/26/17
Depth
(Feet)
1- TOPSOIL
2- .1....,
3- -. ..
4-
See Site Plan
5- GM For Testhole Location
• DENSE SANDY
6- GRAVEL W/
7FREQUENT
-
COBBLES
8-
WAS GROUND WATER
9- `' ,• ENCOUNTERED? NO
10- IF YES,AT WHAT DEPTH? NONE
Depth to Water After
11- . Monitoring? NONE
12- -` '- Date:12/03/17
13-
14- Reading Date Gross Time Net Time Depth to Water Net Drop
15- 1 11/29/17 1:08 0 6-0/16 0
16- 2 1:18 10 8-2/16 2-2/16
17- 3 1:19 0 6-0/16 0
18- 4 1:29 10 8-1/16 2-1/16
19- 5 1:30 0 6-0/16 0
20- 6 1:40 10 8-0/16 2-0/16
PERCOLATION RATE 5.0 (minutesfinch) PERC HOLE DIAMETER 6"
TEST RUN BETWEEN 4 FT AND 5 FT
COMMENTS PERC HOLE PRE-SOAKED PRIOR TO TEST.MONITOR TUBE INSTALLED. C, 4 5T 3h 2-6I4RtvA
5.H0t,✓4 - 7C5" R A4, 7--i,g, 6,7 . ;bwi-e c l b AZ.4-1 .P•1,4s
PERFORMED BY: CHARLES BALZARINI I CHARLES BALZARINI CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE.DATE: 11/29/17
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
BETWEEN MUNICIPALITY OF ANCHORAGE
AND John P. Williamson
THIS MAINTENANCE AND REPAIR AGREEMENT made and entered into as of this
11th Day of December of 20 17 , by and between John P. Williamson
herein the "OWNER," and the Municipality of Anchorage, herein the
"MUNICIPALITY." In consideration of the mutual covenants contained herein, the
parties to this Maintenance and Repair Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. Municipality grants permission to
Owner to utilize and operate an Advanced Wastewater Treatment System
(AWWTS), described as
ADVANTEX
located at(legal description).
TONJESS ESTATES BLOCK 3 LOT 12
2. Definitions.
Alteration. Any change to the design or function of an AWWTS that
includes the installation or removal of any parts, components or pieces not
included in the original construction permit and design.
Certificate of On-Site Systems Approval (COSA). An approval by the
Municipality of existing water and wastewater disposal systems given at
the time of property sale and title transfer in accordance with Anchorage
Municipal Code (hereinafter, "AMC") 15.65. These approvals certify that
the systems are adequate for the homes that they support and meet the
codes that were in place at the time of system construction.
Damage. Any man-made or natural change in a system that would inhibit
the system from performing as designed.
Maintenance and Repair. The scheduled and as needed replacement of
existing parts, components and pieces of an AWWTS that were included
in the original design which would allow the AWWTS to continue to
perform as designed.
Permit. An On-Site Wastewater Disposal Permit as required by AMC
15.65 to construct and operate an AWWTS.
3. Term. The term of this Maintenance and Repair Agreement shall begin on the
date of approval by the Municipality to operate the installed system or issuance of a
COSA, and shall continue while the AWWTS is in use or is operational or until the
property is sold or title is transferred by the owner and a new COSA is issued to the
new owner or transferee of the property.
4. Alterations, Installation and Removal of Additional Equipment. Prior to
performing any alterations to an AWWTS, the owner agrees to obtain an On-site
Wastewater Disposal Permit from the Municipality in accordance with AMC 15.65.
5. Maintenance and Repairs.
A. Throughout the term of this Maintenance and Repair Agreement, the Owner shall
maintain their AWWTS in a satisfactory condition capable of producing treated
septic effluent in accordance with the equipment's approval for operation in the
Municipality. The owner shall enter into a service agreement with an AWWTS
service and maintenance provider approved by the municipality and the
manufacturer of the AWWTS for the entire term of the AWWTS. In addition, it
shall be the responsibility of the Owner during the term of this Maintenance and
Repair Agreement, and any renewals thereof, at the owner's sole expense,to pay
for any and all: (1) repair(s), (2) maintenance, (3) adjustment(s), (4) replacement
costs, and (5) inspection costs.
B. Owner agrees to comply with all applicable ordinance, laws, regulations, rules
and orders for the AWWTS.
C. Upon request by the Municipality, the owner agrees to provide the Municipality a
written schedule of routine maintenance and repairs which have been performed
on the system. When a record of maintenance is documented and maintained by
the system vendor, the owner agrees to allow the Municipality access to this
information.
D. Owner acknowledges that the fine for failing to maintain and repair an AWWTS
may be assessed in accordance with AMC 14.60 for improper discharge.
E. Owner agrees that only maintenance and repair personnel approved by the
Municipality will inspect and make any necessary maintenance, repairs or
permitted alterations to the system.
F. Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS upon 24 hours written notice.
G. Owner agrees that any sale or transfer of title of the property will not occur
without a new Certificate of On-Site Systems Approval.
H. Owner agrees that the AWWTS installation and maintenance requirements as
provided by the AWWTS vendor/installer and approved by the Municipality are
the governing guidelines for the construction, maintenance and repair of the
Owner's AWWTS.
I. Owner agrees to provide and maintain a telephone connection to the AWWTS as
required by the AWWTS approval.
6. Nonwaiver. The failure of either party at any time to enforce a provision of this
Maintenance and Repair Agreement shall in no way constitute a waiver of the
provisions, nor in any way affect the validity of the Maintenance and Repair
Agreement or any part hereof, or the right of such party thereafter to enforce each and
every provision hereof.
7. Amendment.
A. This Maintenance and Repair Agreement shall only be amended, modified or
changed by a writing, executed by authorized representatives of the parties, with
the same formality that this Maintenance and Repair Agreement was executed
with, and such writing shall be attached to this Maintenance and Repair
Agreement as an amendment.
B. For the purposes of any amendment modification or change to the terms and
conditions of this agreement, the only authorized representatives of the parties
are:
a. Owner: John P. Williamson
b. Municipality: Director, Community Development or designated authority
C. Any attempt to amend, modify, or change this contract by either an unauthorized
representative or unauthorized means shall be void.
8. Jurisdiction: Choice of Law. Any civil action arising from this Maintenance
and Repair Agreement shall be brought in the Superior Court for the Third Judicial
District of the State of Alaska at Anchorage. The laws of the State of Alaska shall
govern the rights and obligations of the parties under this Maintenance and Repair
Agreement.
9. Severability. Any provisions of this Maintenance and Repair Agreement decreed
invalid by a court of competent jurisdiction shall not invalidate the remaining
provisions of the Maintenance and Repair Agreement.
OWNER:
/l,
By: (signature) Date: 11 Dec 2017
John P. Williamson (print name)
STATE OF ALASKA )
) ss.
THIRD JUDICIAL DISTRICT ) /�
�
The foregoing ,/�
-st ment ackne , ledged before me this 1/ day of 'nceol/J ,
20/7-, by e,.7 c. c _� .
�" SCHFF,I '►
PI
NOTARY PUBLIC -tea R ALASKA :�e.�;:' ;9cp ',,i
My Commission/pires: 7ci t 3. Zo2c2 ."Z; to*ARY : s
i to..'-ie = E i
•E. PUB1-‘G �: Ai
1
4%' ';e of..� • �_=
ililt e`on E`p`;0:.-'
MUNICIPALITY:
By: ,� , / iff .�. ,1 (signature) Date: 1Z//3/17
(print name) Title:
(' '~ MUNICIPALITY OF ANCHORAGE ~'%/
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEGAL DESCRIPTION
LOCATION
D,STANCETO,
~OZ~ ~ DISTANCE TO: Iwe' ~lling
Length Width
~ ~ T~pe of ~rib Crib diameter Crib depth
m Well Building f~n~tion
~ DISTANCE TO:
~ Class / ~epth ~ Driller
~ DISTANCE TO:
NO. OF BEDROOM~.~
Ma~_~_. No. of compartments 2~
Liquid deptL
PERMIT NO.
Liquid capacity in gallons
Distance between
To,.,
PERMIT NO.
Total etlective absorption
Nearest lot line
Distance to lot line I PERMIT NO.
Septic tank I Absorption area(s)
OTHER
PIPE MATERIALS
/
REMARKS
MUN I C~ I P~J~IL I T¥ OI=- i=tNC:HClI=~I=IGE
DEPARTMENT 0 ~EALTH AND ENVIRONMENTAL ! ~TECTION
825 L°STREET, ANCHORAGE, AK ~9501
264-4?20
ON--SITE $£WER & ~ELL PERMIT
PERMIT NO:
DATE ISSUED:
APPLICANT:
ADDRESS:
'CONTACT PHONE:
840383
05/24/84
KIMPTON BUILDERS
~ SiS ENGINEERING
EAGLE RIVER, AK 9~577
~4-2~?~
LEGAL DESCRIP: SUBDIVISION: TONJESS EST. LOT: t2 BLOCK:
~' SECTION: 2 TOWNSHIP: iSN RANGE: IW
LOT SIZE: 45553 (SQ. FT. OR ACRES)
MAX BEDROOMS: 3
~LISTED BELOW ARE THE OPTIONS AVAILABLE TO YOU IN DESIGNING VOUR SEPTIC
i, SYSTEM. -CHOOSE THE OPTION THAT BEST FITS YOUR SITE.
,DEPTH TO ~IPE BOTTOM (FT.> 4.0 5 4.0
iORAVEL DEPTH (FT.) 6.0 d 0.5
10. O
ITOTAL DEPTH 4FT.)
~GRAVEL WIDTH <FT.) ~ 2.5 >~ 17.0
TGRAVEL LENGTH (FT.) -~2.0 ~1' 34.0
~GRRVEL VOLUME (CU. VDS.)
i!TANK SIZE <GALS) ~,000.0 ~* ~,000.'~
'~SOIL RATING CSQ. FT./BR)
4.0
7.5
4:!.. 0
-- 30. 3
~ _~*_TRNK _MU_ST HRV_E RT LEAST TWO COMPARTMENTS
"I'CERTIFY THAT:
.1. I AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS RS SET
.FORTH BY THE MUNICIPALITY OF ANCHORAGE (MOA) AND THE STATE OF ALASKA.
2. I WILL INSTALL THE SYSTEM IN ACCORDANCE WITH ALL MOA CODESRND REGULATIONS,
.AND IN COMPLIANCE WITH THE DESIGN-CRITERIA OF THIS PERMIT.'
3.' I WILL ADHERE TO ALL HOR AND STATE OF ALASKA REQUIREMENTS FOR THE SET BACK
DISTANCES FRON ANY EXISTING WELL, WRSTEWATER DISPOSAL SYSTEM OR PUBLIC ..
SEWERAGE SYSTEH ON THIS OR ANY ADJACENT OR NEARBY LOT.
· '4. I UNDERSTAND THAT THIS PERMIT .IS VALID FOR A HAXIHUH OF 3 BEDROOMS AND "
ANY ENLRRGENENT WILL REQUIRE RN ADDITIONAL .PERMIT..
IF R LIFT STATION IS INSTALLED IH RN AR~A COVERED BV MOA BUILDING CODES,
THEN (i) AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTRINEDJ (2) RS-BUILTS
WILL NOT.BE APPROVED WITHOUT RN ELECTRICAL INSPECTION REPORTJ AND (3) THE
ELECTRICAL WORK MUST BE DONE BY R LICENSED ELECTRICIAN.
DflTE:
....... ., ,
.RPPLICRNTi KIMP~O~ B~JILDERS / ' .
MUNICIPALITY OF ANCHORAGE Q PERCOLATION
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION TEST
1~25 L. Stfe~t, Anchorege, At.~t~a 99501 264~4720
SOILS LOG - PERCOLATION TEST
PERFORMED FOR:
LEGAl. DESCRIPTION:
3-: ...~
4-
5-.
7-
lo- q
,, .~'~
11-~ · '
~4.
15-
16-
17-
18-
19-
20-
MUNICIPALITY QF ANCHOI~E
DEPT. OF HEALTH &
ENVII~ONMENTAL PROTECTION'
MAY 3 g ~984 WASGROUNOWATER H b
ENCOU.TE.ED~
OATEPE..ORMEO:
RECEIVED, ..,,T,,,.AT
· DEPTH?
SITE PLAN
P
E
Gross Net Depth to
Reading Deta Time T~me Wate¢
b l/A
COMMENTS
.,---
P~RFORM[D
Net
Drop
** MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date Ju.~lg 2~ 1986
GENERAL INFORMATION
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 15; 8t. ock $; Tonje66 E6t~tte6
Location (address or directions)
(b) Applicant Name K.~ptoll. Telephone: Home 68 J-5 ! 75 Business
Applicant Address P.0. 8ox. 551, C/m.q~.ak, At.~z6k~. 99567
(c) Applicant is (check one): Lending Institution I'-I; Owner/builder ~; Buyer I'1; Other I-1 (explain);
(d) Lending Institution
Address ~[~6Z~-~,
(e) Real Estate Company and Agent non~.
Address
Telephone
(I) · hv,~he HAA to the Iollowing address:
S ~ S
SRB 196X
Telephone
99571
TYPE OF RESIDENCE
Single-Family~ Multi-Family[]
Number of ~edrooms 5
Other
WATER SUPPLY
Individual Well [3: Community [] Public []
Note: It community well system, must have written conlirmation from Ihe State Department ol Environmental Consen. ation
attesting to the legality and status.
SEWAGE DISPOSAL
Onsite I'~ Public [] Community [] Holding Tank r"l
Note: Il community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page I of 2 72-o~1.,~)
o
ENGINEERING FIRM PROVIDING ~elSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health
· Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type ol structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal end State codes, ordinances, and regulations in effect on
the date of this inspection.
S & $ ENGINEERING Telephone ~ ~>(-'~' "' ~- ':~ ~' ~
Name of Firm ~ B ~ 96X
Address EAGLE-RIVER, AK 99577 ,.~ 6 IS
Date
DHEP APPROVAL '*~ . ~
Approved for "~t~'~- bedrooms bg~J~'~
Approved ,~ Disapproved
Terms ol Conditional Approval
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a coudesy to purchasers of homes and their lending
Institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors.or omissions in the
professional engineer's work.
Page 2 of 2
DE'~',r OF
MUNICIPALITY OF ANCHORAGE (MOA,~
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720
Legal Description: ./-- /Z. /~ -~
Well Classification If A, B, C, D.E.C. Approved (Y/N)
Well Lo~ ~>~s~nt~,~.. - .. Cate Completed ~" ~ ~/' Yield
-- -" U ,%..z ·
Total Depth ~ Cased t~ ',~* Depth of Grouting
Static Water Level ~ ~---'
Casing Height Above Ground ./4/
Electrical Wiring in Conduit ~
Separation Distances from Well:
To Septic/Holding Tank on Lot /~,~-- r
To Nearest Edge of Absorption Field on Lot //8 ·
To Nearest Public Sewer Line ~/~'
Pump Set At
Sanitary Seal On Casing~/N~
Depression Around Wellhead
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer
Cleanout/Manhole ~'""',~__,,_[
Water Sample Collected by ~'~ ~ ~'~ '~-~.'""/¢ Date
Water Sample Test Results
Comments "~ ~:~[l~r-o~lc. ,~n,¢ PROTFCTiON
JU I 0 9
SEPTIC/HOLDING TANK DATA
Date Installed ~'~'~/-'~/' Size
To Nearest Sewer Service Line on Lot
Standpipes ~d/N) Air-tight Caps
Depression over Tank
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well
To Property Line
To Water-Meiw/Service Line
Course
Comments '~ ~h~t~'~'
RECEIVED
No. of Compartments
Foundation Cleanout
~//~Date Last Pumped
; for
Temporary Holding Tank Permit (Y/N)
,'/~ ~ ! To Building Foundation ~ '
,~"~ ' " To Disposal Field .5-- ·
Z.. ~" / ~' To Streaml Pond, Lake, or Major Drainage
Page I of 2
72-026( 11/84 )
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed 7_z 4//~ ~' 5/'
Width of Field .5'-o
Square Feet of Absorption Area
Depression over Field ~
Results of Last Adequacy Test
Separation Distance from Absorption Field:
Type of System Design
Length of Field
Depth of Field
Gravel Bed Thickness
Standpipes Presen~lq~
Date of Last Adequacy Test
To Water-Supply Well
To Building Foundation
Lot
To Water I~m~/Sen/ice Line
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area. or Vehicle Storage Area
Comments
To Property Line
To Existing or Abandoned System on
; On Adjoining Lots
To Cutbank (if present) '"'/~
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Comments
Dimensions
Manhole/Access (Y/N)
"Pu~p Off" Level at
/,,~'/ Vent(Y/N)
· /,,/~_ Pumping Cycles during Adequacy Test. Meets MOA
Check Permitted Bedroom Rating Against HAA Request **
Compa~l~J~p.~~.__. MOA No. ~"J'---~:;~ '-~
Receipt No. ~ ,,~4:~ ~ ~
Date of Payment ~/~
Page 2 of 2
Location (address or directious)
(b) Applicants Name ~?pT~A/ /~U/LDC'/~$ Telephone - Home Business
Applicants Address
(c) Applicant is (check oue) Lemting Institution ~-~; Owner/builder~.
Buyer[----]; Other~-~(explalu);
(d) Lending Institution
Address
(e) Real Estate C~. & Agent ~f~
Address
(f) Mail the NAA to the following address:
2. Type of Residence
Slngle-Family~
Number of Bedrooms
Water Supply'
Individual Well~
Multi-Family ~-~
Telephone
Other (describe)
Comm i -- Publioj--7
Note: If community well system, must have written confirmation from the State
Department of Environmental Co.server[on attesti~g to the legality and status.
Sewage Disposal
Onsite,~ Public~--~ -Community[--~ Holding Tank[---~
Note: If community yell system, ~uet have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 2]
Bn§lneering ~ttm ProvidinS Inspections, Tests, File Search, Data and Infor~atio~
Ag certified By my seal affixed hereto and as of the validetion date shorn belov,
verify thaC my investiSation of this Eealth Authority Approval sho~ Chat the
va[er supply and/or vas[eva[er disposal system is safe, functional and adequate for
the number of bedrooms and ~ype of structure indicated herein. I further verify that,
based on the information obtained fro~ the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wustewater disposal
system is in compliance with all Municipal and State codes, ordinances, and re§ula-
tions in effect on the date of this inspection.
Name of Flr~ Telephone
Address · . $~,~1 I~,~X . --,{ OF
Te~s of ~lCtong Approval
CA~ION
T~ MUNICIPALITY OF ANCHORAGE I~PAR~HENT OF Ii~ALTH ~ND ENVIROh~I~NTAL PROTECTION
(DEEP) ISSUES HEALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPEh~ENT PROFESSIONAL ENGIh~ER REGISTERED
IN THE STATE.OF ALASKA. Tlfl~ IltEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES AND
THEIR LENDING INSTITb~IONS IN ORDER TO SATISFY CERTAIN FEDERAL ~ND STATE REQUIRE-
MI~NTS. DIPLOYEES OF D[tEP DO NOT CONDUCT INSPECTIO~ OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE HUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSION~ LN ~ PROFESSIONAL ENGINEER'S WORK.
(DEEP SEAL)
RR4/eJ/Ol8
[Page 2 of 2]
7-19-84
MUNICIPALITY (F ANCHO~ (MOA)
HFALTH ~bn~ORITY APP~0VAL (HAA)
CHECKLI~ - FEBRUARY 1984
Ao ~ELL
MUNICJPAUTY OF ANCMORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
RECEIVED
Total Depth ~ ~O I Cased to
Static ~ater ~1 SF- /
Casing He~.gh9 .Abo~ G=c~nd / 5~"
' Sepa=ation Distan(~s f~ Well:
!
To Septic~Tank ~n Lot' /0~
~ To Neaxest Edge of Abso=ption Field on Lot
'To Nearest Public Se~= Line /J /~
Sanita~my Seal on Casing ~
Del~ession A=ound Wellhead ,(~
: On Adjoining Lots MA~OPO
//8 ! on d oining Lots
TO Nea=est Public Se~r
Cl~ancut/Manhole /-) //%' To Nearest Sewer Service Line on Lot
Be
SE~,'ICAk~9~NG TAS~ I1%TA
De. Installed 7/~-~/~F Size /~ No. of Compartments
Standpi~es~)N) ai~-tight Caps ~N) F~n~ti~ C~a~t ~)
m~essi~ ~ Ta~ (Y~ ~ ~t~d
Holdi~ Ta~ Hi~te= ~a~ (Y~)'~ ~ ~ldi~ Ta~ ~t {Y~)
~ati~ Dist~s ~ ~ptic~iah~
To Building Foundation '~
To Disposal Field .b~''','
To St~e~, Pond, Lake, c~ Major D=ainage
Comments
[Page 1 of 2]
2-15-84
C. ABSO~TIGN FIELD ~TA
Soils ~ating in Ab~o=p~c~ S~rata
Width of Field
Square Feet of Abs.orptic~ Area
~e~i~ ~r Field (Y~
~sul~ of ~st ~
· Length of Field ~ !
D~pth of Field /~ /
~a~l ~d ~i~ss ~/"
~ Sta~ims ~e~nt ~)
'To Building Fogndation
To ~r ~i~rvi~ Lir~ ~/~ ' ~ ~(if ~nt)
, To ~i~y, ~ki~ ~ea, ~ Vehic~ St~ ~a ~ ~
D. LI~T STATION
Date Installed Dimensions
Size in Gallo~ Mar~ole/A~cess (Y/N)
"Pump On" Leal at "Pump Off" Level at
High Water Alarm Level at / --/ Vent (Y/N)
· Tested 'fo~ ~/~~ during Adequacy Test. Meets
..'~lect.trical Codes(Y/N)
** O~eck Permitted Bedroom Rating AGainst }{AA B~quest
I ~s=tify that T have chsc~d, verified, c= con. f~d to all FIOA }{AA _(~_ 4~s in effect
on the date of this_inspecticn. ~ O~
Signed .... ? SRB l~X · ·
·, ~, ~<*'. ..... ·.
[Page 2 of 2]
2-15-84
825 'L" Street
R~k Mystrom, P.O. Box 196650 Anchorage, Alaska 99519-6650
Mayor
http://www.ci.anchorage.ak.us
March 15, 2000
Jeffrey Gamess
Alaska Water 8: Wastewater Consultants, Inc.
6901 Debar Road, Suite 2-B
Anchorage, AK 99503
Subject:
Waiver Request for Tonjess Estates, Lot 12, Block 3
Waiver Request #WR000012
Parcel ID #051-532-04
HA000083
Dear Mr. Garness:
Your request for a waiver of the required 10 feet horizontal separation from the
on-site wastewater disposal system to property line has been approved. The approved
separation distance is 4.0 feet.
This waiver approval applies to the existing on-sitewastewaterdisposal system to
property line separation only. Any future upgrade to the on-site wastewater disposal
system will require all separation distances be met or another approval from this
department.
If there are any further concerns or questions regarding this waiver, please call our office
at 3434744.
Sincerely,
Daniel J. Roth
Civil Engineer
On-Site Water Quality Program
MUNICIPALITY OF ANCHORAGE
Department of Health & Human Sewlces
On-Site Services
Waiver Review Worksheet
WR# WRO00012 PID#: 051-§32-04 HAft: HA000083
Date Received: March 8, 2000
Legat Description: Tonjess Estates, Lot 12, Block 3
Engineer:. Alaska Water & Wastewater Consultants, Inc.
6901 Debarr Road, Suite 2B, Anchorage, AK 99503
Permit~
Applicant: Richard & Rosanne Kimpton
Waiver Requested: I foot lot line waiver.
Criteria: 1. Geology Points:
A. Water Table
B. Soil Sorpfion
C. Permeability
D. Water Table Gradient
E. Horizontal Separation
2. Special Conditions:
Total:
3. Other:.
Waiver is Gmntad: X,
List Conditions or Reasons for above:
~ F- ,7
Waiver Is not Granted:
Date:
Rec/f: 05779 Amount: S115.00
By: P/~ ~,/
Name of Reviewer
Date Paid: March 8, 2000
"' ~:'"" ' ....... HEALTH & HUMAN SERVICES
Date ~, /~. ~ ..... ., .,,.,.,.~
~,~ ~ .;. ~ ~ M~l~~mge ~enl of H~I~ ~nd Human ~ (DHHS) ~u~ Hea ~ ~od~;' ~.~ ..... . :.
:: .~, :. ~ ,,~p~l ~fl~.~ on~ u~n ~e mp~n~flons g ven In ~mgmph 5 a~ve by an Inde~ndent ? ;'-r ~., ~, . -
...,., ~ ~ DHHS do not ~ndu~ Ins~o~ or anal~e da~ be~m a m~te ~ ~u~,~e Mun dna ~ of r;, '- ~ .g-'.~:..-' ' ,.
:..:..: ~; :~ ~ge b .~ot ~lble ~r e~m or oml~lons In ~e pmfe~lonal enginee~s wo~.~, "t~ ~:..;'; ¥7' ;~"'~ ;, '."~ .':: F.::
Legal Description:
A. WELL DATA
Well Type PRNATE
Log present (Y/N)
Total depth 280'
Sanlmy seal (Y/N)
CEIVED
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVI'b'~Oe ~000
Environmental Services Dlvleton
Health Authority Approval Checklist
TONJESS ESTATES S/D; LOT 12, BLOCK 3 PamelI.D.:
FROM WFI I LOG
Date of test 6/15/84
Static water level 52'
Well production 0.4 g.p.m.
WATER SAMPLE RESULTS:
Date of sample: 2/29/2000
B. SEPTIC/HOLDING TANK DATA
Date Installed 8/14/84 Tank size
Foundation deanout (Y/N) YES
Data of Pumping 8/19/1999
C. ABSORPTION FIELD DATA
Data installed 8/14/84
Length ~ 27'
Effective absorption area
Date of adequacy test
Ruld depth In absorption field before test (In.);
Fluid depth 0' (ins) Minutes later.
Peroxide treatment (past 12 months) (Y/N)
051-552-04
~A,B, orC, attachADEClette~ADECwatarsystem number N/A
YES Data competed 6/13/84
Cased~ ~6.~'~OBEDROC~ Caslnghe~bevegmund) 10"
YES Wimspmperlypmtactad(Y/N) YES
ATINSPEC~ON
2/22/2000
65'
0.6
g.p.m.
· bq m~/L
Other bacterle
Co,,c d NC.
1000 Number of Compartments 2 Cluanouts (y/N). YES
Depression (Y/N) NO High water alarm (Y/N) N/A
Pumper JR'S PUMPING
*SUMP HAS BEEN PARqlALLY FILLED WITH DIRT.
30 INCHES OF EFFECTIVE MEASURED IN FIELD
Soil rating (g.p.d./lt2 or fl2/bdrm) 125 System bjpe TRENCH
Width 4.2' Gravel thlclmese below pipe '7' Total depth * 10.5"
378 SQ.FT. MonlteflngTubepmsent(Y/N) YES Deprseslenoverfiald(y/N)' NO
2/22/2000 Results (Pass/Fall) PASS For 3 Bedrooms
,**0" Immedletaly alter 457 gal. water edded (In.): 20.5"
1411 Absorption rata = **450+
NONE KNOWN If yes, give date
· *'1000 GALLON WATER HAUL ADDED PREVIOUS DAY
D. UFT STATION
'Datum
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
SepUc/holdlng tank on lot
Absorption tteld on lot
Public sewer main
8ewer/se~c so.ce line
100'+ On adjacent lots 100'+
100'+ On adjacent lots 100'+
N/A Public sewer manhole/cleenout N/A
25'+ Lift stafion N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Foundation 5'+ Property Une 5'+
Water maln~son4ce line 10'+ Surface water/drainage 100'+
SEPARATION DISTANCES FROM ABSORPTION FIELD ON LOT TO:
Property llne
Surface water
Curtain drain
'1'+
Building foundation
1 oo'+
NONE KNOWN
Absorption field 5'+
Wells on adjacent lots 100'+
*SEE WANER REQUEST L~.I le.R
10'+ Water maln/sondce Ilne 10'+
Driveway, parldng/vehlcle storage ama 50'+
Wells on adjacent lots 100'+
Waiver Fee $
Date of Payment
Receipt Number
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
February 25, 2000
Municipality of Anchorage
Department of Health and Human Services
On-Site Services Section
P.O. Box 196650
Anchorage, Alaska 99519-6650
Ref: Lot Line Waiver for Lot 12, Block 3, Tonjess Estates Subdivislon
To whom it may concern:
We request that your department issue a 1 foot lot line waiver from the noah property line to the
existing drainfield. The encroachment is shown on the attached Registered Land Surveyor Robert
Johnson's As-built survey dated June 2, 1986.
I am unaware of an/y/~.dverse impacts this waiver would have on adjacent wells or septic systems.
If you have anyq~e~ttions, please contact us at 337-6179. Th.ank you for your assistance.
,~/
6901 Debarr Road, Suite 2B ~ Anchorage, AK 99504 ~ Ph: (907)337-6179 ~ Fax: (907)338-3246
" .~ .~,~. ..**..,*~. ,
!~.*.*-. .,.
· .. .~ .,,.*** ,.. .. I.~ ~..**! ......
i .:'~ . ..,~. .. .. .
· ·U · ~ I ,.. , ,
, .. ~ *.,, ". .,~j., "...,A,.,'~ , ..o,. ...**.
· . ~ - .. .~ ~ ~. · .'~r..*~ .... , .
· ... ~., ...,, 4._ ,~'.~.~ ........- ,. . .._-. ...~:
,.. .~;~ ~,i~,.,~...~9~. ....... ,~ .. ...- .... .. .~ .....
. . . ~ ~ ; .~ ~'1~'~. .._ .,.~,. ,,. .,.. ~.,_. o~
i~' ' . ,~,~'~ ,~'" .,,.'.,.._.~.'~ ....."..'. v.,'... .,, 6!.:,.'/ ~:.::.':
'.~ * .,. .~,~'; ... ~,~1._..-'":'"'~ ,.."- .. ,. ..."~, ,, ... ,'/~ ·
· ,...,. ·., .. ,... ~'~,~.,:.~.'..~.'.~ . _...,.~:,.~**...,. ...... .~.,.. .:..~, ... '.,~....:,.....
· . ~.. ****~ ..*~ ... .... ~,~,.~,, ....,.~o.~'._ .".. ·, ~- ...... . . .'. ** ~ ·. .. -
'"· ....'. '.M ~, , '. ,, · · . ~, . . ' o . ~'. ·
~ · ,",~ · *~ , :,,." **. ., · .~ ,, , ~, ·
· · ..~ ~. . ,,,....,... .... · ./ .... ...
· · · , · *" ~*~, o , ·" °.*.*. ..*...,·*, , , , o ~. ~ · ·
. '~._\. . .... .../. ~.....
.~ /~. .. .... .
i * ' "~ . ~1~I~* · **J * · ·*
· '*· ~' · "' ' i-'~.," ",,".
· . ....
· '· ¥ , -
.. · · . .~ ~! ,F ~,~ '~."~-~ ~ ~
_ .' '. _ ~,~ I~..=~1~ ~',~o ~'~ ~ ~
...-.......... , ,,,,'~,,~'~,~,~~~,~