The pod will have to be replaced if it contiues to bow,
cracks increase or the pod/lid are not water tight
anymore.
Municipality of Anchorage
Development Services Department
Building Safety Division _-= — -
On -Site Water & Wastewater Program, 4700 South Bragaw St. _
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us (907) 343-7904 Page 1 of 3
On -Site Wastewater Disposal System and/or Well Inspection Report
Permit Number: SW060165 PID Number: 020-421-09
Name:
ANATOLI BOIKO
Wastewater System: ■ New ❑ Upgrade
Y pg
Address:
18531 PORTUGAL PLACE * ANCHORAGE, AK 99516
ABSORPTION FIELD
Phone: No. of Bedrooms:
(907) 273-2129 4
❑Deep Trench ■Shallow Trench ❑Bed ❑Mound ■ Other
LEGAL DESCRIPTION
Soil Rating:
3 O
I
Total Depth from original grade:
SEE DWG.
GPD/Sq. Ft.
Ft.
Block: Lot: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
3 1 PARADISE VALLEY
SEE DWG. Ft.
0.6 Ft.
Township: Range: Section:
Fill added above original grade:
Gravel length:
— — —
SEE DWG. Ft.
40 Ft.
WELL: ■ New ❑ Upgrade
Gravel width:
5
Number of lines:
1
Distance between lines:
—
Ft.
Ft.
Classification (Private, A,B,C):
Total Depth:
Cased To:
Total absorption area:
Pipe material:
PRIVATE
229 Ft.
229 Ft.
200+ sQ. Ft.
D 3034/ F-810
Driller:
ALPINE DRILLING
Date Drilled:
7/17/03
Static Water Level:
151
Installer:
DENALI EXCAVATING
Date install d:
10%12-11/3/2006
Ft.
Yield:
Pump Set At:Casing
Height Above Ground:
TANK
20 GPM
215 Ft.
2 Ft.
SEPARATION DISTANCES
❑ Septic ❑ Holding ■ S.T.E.P. ■ Other*
To
Septic
Tank
Absorption
Field
Lift
Station
Holding
Tank
Public/Private
Sewer Lines
Manufacturer:
ANCHORAGE TANK
Capacity in gallons:
1500
From
Well
100'+
100'+
100'+
—
25'+
Material:
STEEL
Number of compartments:
2
Surface Water
100'+
100'+
100'+
-
-
LIFT STATION
Lot Line
5'+
10'+
5'+
—
—
Size in gallons:
Manufacturer:
66
ANCHORAGE TANK ORENCO
Foundation
5'+
10'+
5'+
—
—
"Pump on" level at:
Pump off level at:
High water alarm at:
TIMER 24"
TIMER/12 11
TIMER 26.5"
Curtain Drain
NONE KNOWN
Pump Make do Model:
Electrical Inspections performed by:
#20 OSI 05 HHF
M.O.A.
Remarks: *THIS IS AN ADVANTEX TREATMENT UNIT
BENCH MARK
Location and Description:
TOP OF GARAGE SLAB NEAR POINT "A"
Assumed Elevation:
100.00
Ft.
I
G EG Ltd .
Inspections performed by: Dates: 1st 10/12/2006
ENGINEER'S SEAL
2nd 10/13/2006
000IoOp
0 oF•.Asoo
3rd 11/3/2006
op�P.•o ,�
Development Services Department Approval i
Y* 49 H ..-7 0
�....:...... ... ......0�
Reviewed and approved by: Date:
...................�
.Jeff, ey, Garnes
�q,
e
Reviewed b �C
Date:
and a pp y roved
(Rev. 4/06)
4 rofessio�
�OOOOQOOp
�';.
NUMBER: AS—BUILT DRAWING PARCEL ID NUMBER:
-
60165 020-421-09
A B
ST1
7.7
34.3
POD
10.6
35.8
MH 1
14.5
37.0
MH2
18.0
40.0
MT1
96.1
85.1
MT2
128.3
120.8
GARNESS ENGINEERING GROUP, Ltd
CONSULTANTS & GENERAL CONTRACTORS
3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 * PHONE (907)337-8179 • FAX (907)338-3248 * WEBSITE www.gameeeenglneeNng.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: I
IRINA & ANATOLI BOIKO 273-2129 2 OF 3
LEGAL DESCRIPTION: DRAWN BY:
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3 C.J.G.
TYPE OF WORK: DATE:
AS—BUILT FOR NEW SEPTIC SYSTEM 3/7/2007
(Rev. 01/05)
00
7 ..::. .... .... .......
�'.Jelf A. am ss:'
E-7953
el
r o f e s si0��oo/
AIT NUMBER:
SW060165 AS -BUILT DRAWING
FINAL GI
= 102
TOP OF TAI
= 96.55
INVERT 01
= 95.
TOP OF MANHOLE
PARCEL ID NUMBER:
020-421-09
TOPSOIL AND SEEDING
COMPLETE PER GEG
INSPECTION 10/23/2009. FILTER FABRI
INSULATION
INVERT OF PIPE
= 144.78 (AVG.)
THE DISTRIBUTION LINE IS 1.25 INCH PVC
WITH 1/4 INCH HOLES SPACED 16
INCHES ON CENTER. (30 HOLES TOTAL)
VAULT
FINAL GRADE = 146.96-147.35
ORIGINAL GRADE
= 144.28
HIGHEST POINT
TOP OF SAND =
144.28 (AVG.)
BOTTOM OF EXCAVATION
= 140.51-143.28
EXCAVATION LIMITED TO
DEPTH OF 12 INCHES
RELATIVE ELEVATION OF BOTTOM
OF TESTHOLE = 136.28 (NO H20)
GARNESS ENGINEERING GROUP, Ltd
CONSULTANTS & GENERAL CONTRACTORS
3701 E. TUDOR ROAD, SURE 101 • ANCHORAGE, AK 99507 • PHONE (907)337-8179 • FAX (907)338-3248 • WEBSITE:—g—sengineering.com
PREPARED FOR: PHONE NUMBER: PAGE NUMBER: I
IRINA & ANATOLI BOIKO 273-2129 3 OF 3
LEGAL DESCRIPTION: DRAWN BY:
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3 C.J.G.
TYPE OF WORK: DATE:
PROFILE AS—BUILT FOR NEW SEPTIC SYSTEM 3/6/2007
(Rev. 01/05)
Qo
0
' � 4p
rte.✓:. .'� . . .. . .. . . . . .
Jk"ffr A. Gar ss.**Q4�' E-79 3
�40'Z_l fessio' �'W
P
907 2764429
i-03 ; 1 0. 1 1AM; REMAX PAO?ER'r 1 ES
Municipality of Anchorage
Department of Health and Human Services
825 'L" Street
P.0 Box 196650 Anchorage, Alaska 99519-6650
Rick Mpsfmrn http:Jtwww.a.anchwage.ak.us
Mayor
P.
;it 5/ , n
Permit Number: #SW 030112 Date of Issue: 5-1-03 Parcel Identification Number: 020-421-09
pate .gtartEd: 7-15-03 Date Completed: 7-17-03 Is well located at approved permit location? ED Yes ❑ No
Legal Ihmeription: Pacatiise Valley Bic 3 U 1
property Owner Name & Addrrss: f� v�`;'� 4i l�
18531 Portugal Place
Anchorage. Alaska 99516
rj3oreholke Data:
pe, nh ac ass& Water Strata
Dept4_ (ft)
Feom ToCasi3ng
Method of Drilling ® air rotary ❑ cable tool
Wpe:steelup
silly gravel"
silty cobb/y gravel
gravelly sift
0 2
2 3
3 17
17 ., 148
Miall Thickness:.250 inches
Diameter.6 inches Depth. 229 fi=t
� doer Type:
Diameter: inches Depth: feel
Casing stickup above groand: 2 feet
Sift
sandy gravewy silt
silty water sand & gravel
148. - 187
187 = 226
.220 "229': `
Static water level (from ground }evel): 151 feet
_Pumping level: 229 feet af_ er .
2 hours pumping 20 gpm
Recovery Rate: 20 gpm
Method of Testing atli ft
Well Intake Opeaing Type:
Open► Ena ❑ Open Hole
❑ Scr=ncd Start feet Stopped feet
❑ Perfora6ons Start feet Stopped Beet
Grout Type: bentonite # 8 Volume; 1 b'q-
Depth: Start 0 feet Stopped ? feet
Pump: Intake Depth feet
Pump size hp Brand blame
Well Disinfected Upon Completion? ® Yes ❑ No
Metbod of Disinfection:
Comments:
Weft Driller_ Alpine Drilling & Enterprises
PO Box 110496
Anchorage Alaska 99511
_ai,tte[ttion: The well dri€le.r shall provide d well loft to the property owner within 30 days of completion and the prvperh-
.I 1� .r •Il i !t 1 fl \ .1 ,', . (err 1.1 C 1r, _. n �1 /n t. C t
Development Services Department
Building Safety Division
PSE G1
On -Site Water & Wastewater Program
' 4700 Elmore Street
P.O. Box 196650
Mark Begich Anchorage, AK 99519-6650 s .4 F E T Y
Mayor www.muni.org/onsite
(907)343-7904
Pump Installation Log
Well Drilling Permit Number: SW
Date of Issue:
Parcel Identification Number: Replacement Only: YES NO
11 Legal Description 11Property Owner Name & Address: 11
Lot 1, Block 3,Paradise Valley
Pump Installation Date: Original install by owner in 2007
Pump Intake Depth Below Top of Well Casing: 215 feet
Pump Manufacturer's Name: Sta-rite
Pump Model: 7P4FO2JL-04
Pump Size 1.5 hp
Pitless Adapter Burial Depth: 15 feet
Pitless Adapter Manufacturer's Name: cambel
Pitless Adapter Installer: Aarow Pump & Well Service LLC
Well Disinfected Upon Completion? ® Yes ❑ No
Method of Disinfection: Recire
Comments:
Dan Pots
18531 Portugal Place
Anchoraze,AK.99516
Pump Installer Name: Aarow Pump & Well Service LLC
PO Box 110496,Anchorage, AK 99511
(907) 346- 9355
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
Inspection Report
Municipality of Anchorage, Building Safety Division
4700 Elmore Road
INFO & HELP (907) 343-8211
INSPECTION: VOICE (907) 343-8300 FAX (907)249-7777 www.muni.org
Name solid ground elec Permit # 05-0733
Company Inspection Date 16 -Jul -2009 PM
Address 18531 PORTUGAL PL Phone 727-8008
Grid SW3538
Subdivision PARADISE VALLEY LOT 1 BK3 TR n/a
Work Description 2562 SQ FT LIVING / 665 SQ FT FINISHED BASEMENT/ 783 SQ FT GARAGE
Insp. performed/prepaid 0/0
Permit Technician
Comments or Directions sewer lift station
Inspection, Type Electrical: Other Electrical
Comments (for inspector use only)
p A
Date
,{ Inspection Report
Municipality of Anchorage, Building Safety Division
4700 Elmore Road
INFO & HELP (907) 343-8211
INSPECTION: VOICE (907) 343-8300 • FAX (907)249-7777 - www.muni.org
Name Aren/Dan Permit # 05-0733
Company Vannoy Electric Inspection Date 15 -Sep -2010 AM
Address 18531 PORTUGAL PL Phone 441-1061
Grid SW3538 230-8393
Subdivision PARADISE VALLEY LOT 1 BK 3 TR n/a
Work Description 2562 SQ FT LIVING / 665 SQ FT FINISHED BASEMENT/ 783 SQ FT GARAGE
Insp. performed/prepaid 0 / 0
Permit Technician
Comments or Directions No tech on site. All corrections made. Water bond R garage under sink, Gas L
of boiler. Thanks
Inspector '2 Date ;
Sep 06 06 09:59P
Page VVSp of I ECHONREFORT
NIUNICIpALITY OF ANCHORAGE — BuffiDING SAFFTY DMSION
4700 SOUTH RRAGAW SSTR -T
Fax: (907)249-7777 w"nmunLOF91BSDI'ns-Per-t'ons'cfmt
L?VSPECTrom. Voice. (9177)343-8300
NAME.-
EVSPECTDAM
TONE #PR -ONE ff
ADDRESS
AV
/4 eag M#
BLOCK.
CoAfjWNn OR D&ECYTONS.'
I'M 0FINSPECTION.
Y
C030YENZ's.. (FOR WSPL7CTOR ME OWL 39
�
DATE: L
�--2
Page 1 of 1
Maricle, Kathleen R.
From: Maricle, Kathleen R.
Sent: Friday, July 06, 2007 8:04 AM
To: 'Jeff Garness (kevin@garnessengineering.com)'
Subject: Nag Note
Contacts: Jeff Garness
Good Morning Jeff— I was wondering about the two following expired permits:
Sw060165 Paradise ValleyLl
Sw060l88 Kasilof Hills B2 lO.—No r (Ng7M t t'b P��- S UraczN�
Paradise Valley has inspections called in on it, while Kasilof Hills does not have any. Can you please let me
know what is going on with these permits? Thanks.
Kathleen Maricle
Permit Clerk II
On -Site Water & Wastewater
343-7904 (w)
343-7997 (f)
P.S. See you at 1400 today. 0
`t Vit,
rv\
CIIA _�U ���
3la3Ioa- ulaAaX6 M P`T-U+
Oh�_OL
r0 Saf' (�
0
l A O_A'Q
q Halal Nab-
7/6/2007
W t'd
rf_(dl A
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water& Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Renewal
\N)Fbl"
Date Issued: Jun 19, 2006
Expiration Date: Jun 19, 2007
Permit Number: SW060165 Parcel ID: 020-421-09
Legal Description: PARADISE VALLEY SUBDIVISION BLOCK 3 LOT 1
Design Engineer: 0855 Gamess Engineering Group, LTD Site Address: NHN PORTUGAL PLACE
Owner Name: IRINA & ANATOLI BOIKO
Owner Address: 18531 PORTUGAL PLACE
ANCHORAGE. AK 99516 -
Lot Size: 49353 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
Q Disposal Field [D Septic Tank ❑ Holding Tank ❑ Privy Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, seated, and heated to prevent freezing.
5. The following special provisions.
a.) The upper six inches of the mound absorption field must consist of lop soil and be vegetated sufficiently to
prevent erosion [AMC 15.65.060(1)(6)&(7)].
b.) If the proposed subsurface disposal field will be located in an area that has been filled, Garness Engineering
Group shall determine the suitability of the fill for its intended use [AMC 15.65.060(B)(6)].
10110106
Z),MW
$'7
Received By:
Issued By.
J«Iy
rditis sy z 7 u;ll {tet „r. va {a ale Past, M to:f hele w45 cepa,
'Wov Lic
Date: 15-b ' " ' eq
Date: (-17 —009
Municipality of Anchorage
Development Services Department
Building Safety Division
/ On -Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
ON-SITE SEPTIC/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 0'�0 - 4Lla/-09
Property
Mailing
phone'
9957
Site address
Legal descril
Legal description (Township, Section & Range)
Lot Size 419353 Sq. Ft.
THIS APPLICATION IS FOR (®all that apply)
Absorption Field
9
Septic Tank
12,
Holding Tank
❑
Privy
❑ i
Private Well
v
Water Storage
❑
Number of Bedrooms
it -
THIS APPLICATION IS AN:
Initial ❑
Upgrade ❑ /
Renewal
certify that the above Information is correct. 1 further certify that this application is being made for a
Single Family Dwe ling and is In accordance with applicable Municipal Codes.
(Signature of prok(ty owner or authorized agent)
Permit/Rush Fees: /is 4T Waiver Fees:
Date of Payment: W -4-J-1 Date of Payment:
Receipt Number: TNT9 Receipt Number:
(Rev. 11105)
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
May 17, 2006
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Reissuance of Septic System Permit for Paradise Valley Subdivision; Lot 1, Block 3,
To whom it may concern:
A permit (#SW050110) was granted by your department on May 3, 2005. It is our understanding
that the well has been drilled under this permit; but the septic has not been installed and the
permit has expired. The current property owners are requesting the permit be reissued. On May,
16, 2006, we performed a site visit and found that the house has been framed and appears to be in
the general location shown on our site plan and design drawings. Based upon our visual
assessment, the proposed septic system is able to be installed as previously designed. The area
below the drainfield will still be required to be filled so that no slope within 50 feet downhill of
the proposed drainfield exceeds 25 percent. The special provision of the existing permit will also
still be required. Based upon this information, we request the on-site wastewater disposal permit
be reissued. If you have any questions, please contact us at 337-6179. Thank you for your
assistance.
, M.S.
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507
Ph: (907) 337-6179' Fax: (907) 338-3246 • Website: gamessengincering.com
MUNICIPALITY OF ANCHORAGE
Development Services Department
Onsite Water B Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM ( WATER SUPPLY PERMIT
Initial
Permit Number: SWO50110
Date Issued: May 03, 2005
Expiration Date: May 03, 2006
Parcel ID: 020-421-09
Legal Description: PARADISE VALLEY SUBDIVISION BLOCK 3 LOT 1
Design Engineer: 0855 Garness Engineering Group, LTD
Owner Name: IRINA 8 ANATOLI BOIKO
Owner Address: 18531 PORTUGAL PLACE
ANCHORAGE. AK 99516-
Site Address: NHN PORTUGAL PLACE
Lot Size: 49353 SO. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
❑✓ Disposal Field ❑,/ Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
a.) The upper six Inches of the mound absorption field must consist of top soil and be vegetated sufficiently to
prevent erosion [AMC 15.65.060(1)(6)8(7)].
b.) If the proposed subsurface disposal field will be located in an area that has been filled, Garness Engineering
Group shall determine the suitability of the fill for its intended use [AMC 15.65.060(B)(6)].
Received By.
Issued By.
Date:
Municipality of Anchorage
Development Services Department
j Building Safety Division
Ort -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.sk.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020-421-04 Permit Number
Property owner(s) IRINA AND ANATO I BOIKO Day phone
Mailing address (1) 1605 CACHE DRIVE * ANCHORAGE- AK.
!s9�Ffng address (2) IL231 V6rAU(Vj t CtX e) s, 9g51(oZip Code 99507
Legal description (Lot, Block & Sub'd.) LOT 1 BLOCK 3• PARADISE VALLEY SUBDIVISION
Legal description (Section, Township & Range)
Lot Size 4q' ,q53
Acr Sq.Ft.
Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only
❑
Well Only
❑
Sewer and Well
0
Water Storage
❑
Sewer Upgrade
❑
THIS PROPERTY CONTAINS:
Hot Tub
❑
Jacuzzi
❑
Swimming Pool
❑
Water Softening Unit
❑
Therapy Pool
❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
GARNESS ENGINEERING Ltd.
Permit Fees: W-0 { 175 (ti'e�� � Waiver Fees'
Date of Payment: 6/—Or)' (-IS Date of Payment:
Receipt Number: ��� Receipt Number..
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
April 11, 2005
Municipality of Anchorage
Development Service Department
On -Site Water R: Wastewater Program
4700 South Bragaw Street
P.O. Box 196650,
Anchorage, Ak 99519-6650
(907) 343-7904
Ref: Proposed Well and Septic System for Paradise Valley Subdivision; Lot 1, Block 3,
To whom it may concern:
A permit (#SW030112) was granted by your department on May 1, 2003. We are resubmitting
the design to show a 1500 gallon 3/16" poly coated advantex tank. The proposed 4 bedroom
home will be served by a private well and septic system. Two test holes were excavated on the
property. We are proposing to design the septic system around the 30 foot radius of these test
holes. Due to the limited amount of receiving soils, and the steep slopes, we are proposing to use
an Advantex treatment system and a 5 -wide trench type drainfield. Comments regarding the
design are summarized as follows:
1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring,
and the percolation test results.
2. DRAINFIELD DESIGN: See attached design drawing for drainfield specifications.
3. SURFACE WATERS: There are no surface waters within 100 feet of the proposed septic
system.
4. TOPOGRAPHY: As can be seen on the attached topography site plan, the proposed
drainfield is to be installed on a 20-30 percent slope. The contractor at the time of construction
will fill this slope in with fill to create a slope of less than 25 percent 50 feet downhill from the
proposed drainfield and 35 feet from the alternate site. Also there is a cutbank 50 feet plus from
the proposed drainfield and 38 feet from the alternate site. We request a 35 foot waiver from the
alternate site to this cutbank.
5. WAIVER: A waiver to impermeable soil from the bottom of absorption field was requested
in April 23, 2003. Your department has granted this waiver for the design approved in May 1,
2003. We are requesting to use the previously granted waver.
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507
Ph: (907) 337-6179' Fax: (907) 338-3246' Website: garnessengineering.com
We are unaware of any adverse impacts this installation would have on adjacent wells or septic
systems. If you have any questions, please contact us at 337-6179. Thank you for your
assistance. /
Sincerely,
P.E., M.S.
NOTLV Ayiached is a site plan drawing, a design drawing, two soil log, which are all part of the
design package for this septic system. (Contact G.E.G. Ltd, for 7 page construction specification
letter.)
3701 E. Tudor Road, Suite 101 • Anchorage, AK 99507
Ph: (907) 337-6179 • Fax: (907) 338-3246 • Website: gamcssengineering.com
LOT 23A, BLOCK 4�
PARADIASE VALLEY S 0 LOT 29. BLOCK 4:
PARADIASE VALLEY S/D
N,
LOT 30. BLOCK 4;
PARADLASE VALLEY S/D
411
Q7
LOT 31. BLOCK 4;
PARADIASE VALLEY S/D
PR E
4 8 00
LOT 38. BLOCK 2;
PARADIASE VALLEY S/D
LOT 37. BLOCK 2:
PARADIASE VALLEY S/D
LOT 28, BLOCK 4;
PARADIASE VALLEY S/D
6�'C�
POTTER CREEK
va
ALTERNATE
SITE
(SEE DESIGN
I
I
LOT 3. BUICK .3;
PARADASE VALLEY S/D
TRACT E.,
HILLSBORO S/D
6 0�0-
A ,)
PACE
TRACT A;
HILLSBORO S/D
SYSTEM
2 OF 4).
mJ00' WE] I RADIUS
GARNESS ]ENGINE ERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS —
PREPARED FOR: PHONI NUMBER: PACE NUMBER:
0
IRINA AND ANATOLI BOIKID I OF 4
kL DESCRIPTION:
PARADISE VALLEY SUBDIVISION; LOT 1. BLOCK
� OF WORK:
SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM
(R". DIM5)
R.A.L.
TV=
11/2005
TRACT D;
HILLSBORO S/D
0\
f�'slo
PROPOSED
PROPOSE'//'
WELL
WE LL/
J
r-,
BLOCK 3j;
P'ALOT,2.
RADLASE VALLEY S�
LOT 28, BLOCK 4;
PARADIASE VALLEY S/D
6�'C�
POTTER CREEK
va
ALTERNATE
SITE
(SEE DESIGN
I
I
LOT 3. BUICK .3;
PARADASE VALLEY S/D
TRACT E.,
HILLSBORO S/D
6 0�0-
A ,)
PACE
TRACT A;
HILLSBORO S/D
SYSTEM
2 OF 4).
mJ00' WE] I RADIUS
GARNESS ]ENGINE ERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS —
PREPARED FOR: PHONI NUMBER: PACE NUMBER:
0
IRINA AND ANATOLI BOIKID I OF 4
kL DESCRIPTION:
PARADISE VALLEY SUBDIVISION; LOT 1. BLOCK
� OF WORK:
SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM
(R". DIM5)
R.A.L.
TV=
11/2005
TRACT D;
HILLSBORO S/D
0\
f�'slo
DESIGN CRITERIA/GEG. Ltd. HAS A 7 PAGE
/ LETTER THAT PERTAINS TO THIS DESIGN.
NUMBER OF BEDROOMS:4 / TO OBTAIN A COPY OF THE LETTER
GALLONS PER DAY (CPD): 600 / CONTACT CEG. BY PROCEEDING FORWARD
PERCOLATION RATES: 1.9-2.0 MIN./INCH WITH THIS INSTALLATION, THE ENGINEER,
PROPOSED APPLICATION RATE: 3.0 WELL DRILLER, CONTRACTOR AND
MINIMUM DRAINFIELD SO.FT.: 200 PROPERTY OWNER AGREE THAT THEY
/ HAVE READ THESE SPECIFICATIONS AND
AGREE TO ACCEPT THE TERMS AND
DRAINFIELD DESIGN: , CONDITIONS OUTLINED.
MAXIMUM DEPTH:3 FEET
WIDTH: S FEET / �•c,
FEET
M.OALENHOVE
APPRD SAND FILTER: 2 FEET Rff4s,
EFFECTNE:0.5 FEET
REDUCTION FACTOR: N/A
ACTUAL SO.FT.: 200
PROPOSED 1500 GALLON
/ ADVANTEX TREATMENT SYSTEM
(SEE DETAIL PACE 3 OF 4)
/
/ INSTACLENA NUTATION /
If
vo
`.. Ar�
I ' . PROPOSED
WELL
PROPOSED /
:r
I 1 ALTERNATE SITE
I NOTE: THE 100 FEET CREEK SETBACK N \
AND SOUTH PROPERTY LINE ARE TO \
BE FLAGGED AND STAKED BY A S \
REGISTERED LAND SURVEYOR PRIOR TO 1 40. \
ANY CONSTRUCTION.
0000� �4
oo F,.• F .. CgsppO
GARNESS ENGINEERING GROUP, Ltd. 4 :9
PD1 �
CONSULTANTS 6 GENERAL CONTRACTORS
L nu 0010. W 101 r me oftwL m 00'-0) • w (W7)w 41T r FY (007710-]1" r 00�91L• w..r•�prMs+
PREPARED FOR: PHONE NUMBER: PACE NUMBER: ... •• ......; ••••�
IRINA AND ANATOLI BOIKO 2 OF 4 53
CE—
�Q �' ( 7 �ess; •00
LEGAL DESCRIPTION: DRAWN BY: OO,r \1p0
PARADISE VALLEY SUBDIVISION: LOT 1. BLOCK 3 R.A.L. '•LLl�' oAv
p e�00000
TYPE OF WORK: DATE: OQrofesslo
DESIGN FOR PROPOSED WELL AND SEPTIC SYSTEM 1 4/11/2005
(RY .01105)
40 FEET LONG
I----------------'
�o-------------I
CO
5 FEET - FROM
WIDEI OMT MT O J ADVANTEX
L------------------ - - - - - - - - - TREATMENT
SYSTEM
FILTER FABRI
INSULATION
INSTALL STAKING AND
BRACING AS NEEDED -
5 FEET
.5 FEET OF
EFFECTIVE
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS 6 GENERAL CONTRACTORS
IAI C ROM . 1000 101 N10110MifL M( ,0]01 • N (oonW�'" • M3 (0019Y U • w s�
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
IRINA AND ANATOLI 3 OF 4
LEGAL DESCRIPTION: DRAWN BY:
PARADISE VALLEY SUBDIVISION; LOT 1. BLOCK 3 1 R.A.L.
TYPE OF WORK:
OF PROPOSED DRAINFIELD
(Rw. DINS)
1/2005
3 FEET DEEP
MAXIMUM AT
ANY POINT
a h&
AdvanTex Treatment System
AX Series - Mode la
One (1) 40x96 Pod
INLET
NOTE: THE BOARD INSULATION TO BE
INSTALLED OVER THE SEPTIC TANK k 4'
BEYOND ON ALL SIDES EXCEPT UNDER
THE ADVANTEX FILTER. THIS WILL ALLOW
FOR HEAT TO ESCAPE FROM TANK &
RISE TO THE FILTER ABOVE R.
2' INSULATION-
\lll�
INLET
16
4,
AX20 POD
1500 CALLON
16" POLY COATED
EL ADVANTEX TANK
POSED DRUNFIELD
UFT STATION
BIOTUSE
SCREENED
VAULT
PUMP
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
1101 L TI000 00.0. } 101 • M100MOL Mf 00'JOf • A (Wr'W- t" • FY (WrA3&' " • 0O9R: w�T s"
PREPARED FOR: PHONE NUMBER: PACE NUMBER:
IRINA AND ANATOLI BOIKO 4 OF 4
LEGAL DESCRIPTION: DRAWN BY:
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3 1 R.A.L.
OF WORK:
PROFILE OF PROPOSED DRAINFIELD
(Rw 0IM5)
4/11/200
GARNESS ENGINEERING GROUP, Ltd.
CONSULTANTS & GENERAL CONTRACTORS
SOIL LOG — PERCOLATION TEST
LEGAL DESCRIPTION: PARADISE VALLEY SUBDIVISION; LOT 1. BLOCK 3
PERFORMED FOR: IRINA AND ANATOU BOIKO DA
DEPTH
fleet) TEST HOLE 1
1 ____ ORGANICS
E
5
6
7
8
9
10
11
12
13
14
15
16
17
18
SOIL CLAS
11 ICATIONS
1GWI
• -
NET DROP
(INCHES)
IIIIIIIIIML
SM/ML11:111!11
CL
lIXED w/ GC
FFM OL
2
111111111MH
SP%//%CH
1'
Iff�lflli
•
viii'Sc
—
DEPTH TO DATE
GROUNDWATER
DRY 4/8/2003
DRY 4/15/2003
DATE READING
CLOCK
TIME
NET TIME
(MINUTES)
WATER LEVEL
READING
NET DROP
(INCHES)
4/9/2003 1
3:01
—
6'
—
2
3:11
10
1'
5-
3
3:12
—
6'
—
4
3:22
10
1'
5-
5
3:35
—
6'
—
6
3:45
10
3/4'
5 1/4*
7
3:46
—
6.
—
8
3:56
10
3/4'
5 1/4-
9
3:56
—
6.
—
10
4:06
10
3/4-
5 1/4'
11
4:07
—
6�
—
12 1
4:17
1 10
1 3/4- 1
5 1/4-
19 PERCOLATION RATE 1.9 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 1.0 FT. AND 1.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES ❑ NO
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISHER
COMMENTS:
PERFORMED BY CEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WA$ PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 020105'
05
o�OF A4 Z
GARNESS ENGINEERING. GROUP, Ltd. ©�'�• yV^�
CONSULTANTS 6 GENERAL CONTRACTORS 4 ¢OV
3]01 E FAL' W N IICWIL ,s..r�r�q.mo • • • • • • • • • • • • • • • • • .D
SOIL LOG — PERCOLATION TEST ..... .... ........ 0
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3 If A. OrneSS;
LEGAL DESCRIPTION: u E-79 3 � �' :per
PERFORMED FOR: IRINA AND ANATOU 801K0 DATE: 4/8/2003 s' '•. FOG
�E,coo
DEPTH ____ °°° •ofessl
(feet) ORGANICS ITEST HOLE 2
SOIL CLASSIFICATIONS
3 ;�:ii++ GP ML j
SM/ML GMCL
MIXED w/ GC OL '
a GM/CL N
°• •°• a SW MH
5 �'• : SP CH /
SM ' a i OH
6 SC
7 DEPTH TO DATE1 f 11TH#1 ./''
GROUNDWATER 1 ��,�-1,_�, /f
g DRY 4/8/2003 I TH#2,,
CLAY w/ DRY
9 SAND LENSES ,��
t r -foo'
SCALE -
10
11
DATE READING CLOCK NET TIME WATER LEVEL NET DROP
12 B.O.B.
13
14
15
16
17
18 12 4:05 10
PERCOLATION RATE 2 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
19
TEST RUN BETWEEN 1.0 FT. AND 1.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: 0 YES E3 NO
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISHER
COMMENTS:
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS PERF RMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: 4 2v V
TIME (MINUTES) READING (INCHES)
4/9/2003
1
3:00
—
6'
—
2
3:10
10
1 1 4'
4 3 4'
3
3:11
—
6'
—
4
3:21
10
1 1 4•
434'
5
3:23
—
6'
—
6
3:33
10
1 1 4'
4 3 4'
7
3:34
—
6•
—
8
3:44
10
1'
S'
9
3:45
—
6•
—
10
3:55
10
i'
S•
11
3;55
—
6•
—
1'
5•
o�OF �O4D
o ... CgspO
GARNESS ENGINEERING GROUP, Ltd. T -.'7
X000
CONSULTANTS b GENERAL CONTRACTORS A 4
SNI L TIO011 MdA SUITE 101 • ANCHORAGE. NC M07 • PONE (W7-41n . ruC YO -3]N • NBSIIL • • •
SOIL LOG — PERCOLATION TEST
LEGAL DESCRIPTION: PARADISE VALLEY SUBDMSION; LOT 1, BLOCK 3. G mess.- a
PERFORMED FOR: IRINA AND ANATOU BOIKO DATE: 6/25/2003 '�. E 9;5
fe,y Q�FQO�
(eet) ==- ^° rof1990^°0�
=� ORGANICS TEST HOLE 3 0000��0
SOIL CLASSIFICATIONS
2
GW =LLC ORG '
3 SM/ML :�.ar+i"t GP ML
MIXED w/ GM CIL
q GM/CL GC OL n
°• •°• o SW MH °
5 • t SP CH o-
SM OH
1
6 SC /
7 CLAY w/DEPTH TO DATE
SAND LENSES
B.O.H.
10 I
i 1' - 100'
11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP
12
13
14
15
16
17
18
19 PERCOLATION RATE 3.0 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) .
TEST RUN BETWEEN 2.0 FT. AND 2.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: CALEB GALL
COMMENTS:
PERFORMED BY GEG, Ltd. I, JEFFREY A. GARNESS, CERTIFY THAT THIS WAS/PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
GROUNDWATER
8
DRY
6/25/2003
DRY
7/3/2003
6/26/2003
1
12:57
—
TIME
(MINUTES)
READING
(INCHES)
6/26/2003
1
12:57
—
—
2
1:07
10
1 3 4"
4 1 4"
3
1:07
-
6"
-
4
1:17
10
2 1 4"
3 3/4"
5
1:17
-
6"
-
6
1:27
10
2 1 2"
3 1 2"
7
1:27
-
6"
-
8
1:37
10
2 3/4"
3 1 4"
9
1:37
-
6"
-
10
1:47
10
2 3 4"
3 1 4"
11
1:47
-
6"
-
12
1:57
10
2 3 4"
3 1 4"
MUNICIPALITY OF ANCHORAGE
Building Safety Division
�_,'A;;ITuU4 f dl ell1ll!
DATE: May 1, 2003
TO: File Paradise Valley Subdivision Block 3 Lot 1
FROM: Dan Roth
Engineer II, On -Site Water Wastewater Program
SUBJ: Waiver Request to Impermeable Soil From the Bottom of Absorption Field
The engineer has requested a waiver to an impermeable layer of
soil beneath the proposed 5 feet wide drainfield down to 4 feet instead of
the required 6 feet. The following waiver is granted for the following
reasons:
I The absorption field will be located over 150 feet from'the nearest
water well.
I The soil the absorption field will be leaching into is a SM silty sand
that percolates at 2 minutesrnch. This soil typically treats septic tank
effluent in a relatively short distance.
I There is no water table to at least 17 feet.
I The lots in this area are 1 acre in size thus density is low
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water& Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT
Initial
Permit Number: SW030112
Date Issued: May 01, 2003
Expiration Date: Apr 30, 2004
Parcel ID: 020-421-09
Legal Description: PARADISE VALLEY SUBDIVISION BLOCK 3 LOT 1
Design Engineer: 0041 AK Water & Wastewater Consultarr Site Address: NHN PORTUGAL PLACE
Owner Name: MICHAEL A. & KARLA A CANNATA Lot Size: 49353 SO. FT.
Owner Address: NHN PORTUGAL PLACE Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE, AK 99516 -
This permit is for the construction of:
❑✓ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑✓ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
1
Issued By: tj I, Date: S 1Q�_
MUNICIPALITY OF ANCHORAGE' "'==
Building Safety Division K ,
sw err
MEMORANDUM
DATE: May 1, 2003
TO: File Paradise Valley Subdivision Block 3 Lot 1
FROM: Dan Roth
Engineer II, On -Site Water Wastewater Program
SUBJ: Waiver Request to Impermeable Soil From the Bottom of Absorption Field
The engineer has requested a waiver to an impermeable layer of
soil beneath the proposed 5 feet wide drainfield down to 4 feet instead of
the required 6 feet. The following waiver is granted for the following
reasons:
I The absorption field will be located over 150 feet from the nearest
water well.
I The soil the absorption field will be leaching into is a SM silty sand
that percolates at 2 minutes/inch. This soil typically treats septic tank
effluent in a relatively short distance.
I There is no water table to at least 17 feet.
I The lots in this area are 1 acre in size thus density is low
Municipality of Anchorage
• ''� Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
e 'Eck c.cTh:.<
°
eA [,.
Parcel I.D. 020-421-09 Permit Number 5-W (O 3 0/I Z
Property owner(s) MIKE CANNATA Day phone 301-0754
Mailing address (1) 360 EAST 160th AVENUE • ANCHORAGE. AK
Mailing address (2)
Zip Code 99515
Legal description (Lot, Block & Sub'd.) LOT 1. BLOCK 3: PARADISE VALLEY SUBDIVISION
Legal description (Section, Township & Range) N 1A
Lot Size 9 ! 5_r3 Acres/Sq.Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only ❑ Well Only ❑
Sewer and Well 0 Water Storage ❑
Sewer Upgrade ❑
THIS PROPERTY CONTAINS:
Hot Tub ❑ Jacuzzi ❑
Swimming Pool ❑ Water Softening Unit ❑
Therapy Pool ❑
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal codes.
ALASKA WATER & WASTEWATER CONSULTANTS, INC.
Signetr:►e e%preper{y owner er�ulHortzed egent}
Permit Fees: �55_0°C�
Date of Payment: 4.215'03
Receipt Number:
Waiver Fees:
Date of Payment:
Receipt Number:
ALASKA WATER Er WASTEWATER
CONSULTANTS, INC.
April 23, 2003
Municipality of Anchorage
Development Service Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
Ref: Proposed Well and Septic System for Lot 1, Block 3; Paradise Valley Subdivision
ADVANTEXTM TREATMENT SYSTEM
To whom it may concern:
1. GENERAL: The proposed 4 bedroom home will be served by a private well and septic
system. Two test holes were excavated on the property. We are proposing to design the septic
system around the 30 foot radius of these test holes. Due to the limited amount of receiving soils,
and the steep slopes, we are proposing to use an Advantex treatment system and a 5 -wide trench
type drainfield. The well is to be located in the area shown on the site plan.
2. SOILS: See the attached log, which shows the soil classifications, groundwater monitoring,
and the percolation test results.
3. DRAINFIELD APPLICATION RATE: A percolation test was performed in test hole #1
and #2 between the depths of 1.0 to 1.5 feet and found the rates ranged from 1.9 to 2.0
minute/inch. The Advantex system has received class III approval and we are going to
conservatively assume an application rate of 3.0 GPD/FT2.
4. TRENCH DESIGN:
a. Percolation Rate: 1.9 & 2.0 minutes/inch
b. Proposed Application Rate: 3.0 gallons/day/ftZ
c. Number of Bedrooms: 4
d. Design Flow: 600 gallons per day
e. Minimum Absorption Area: 200 ftZ
f. Total Depth: 3.0 feet (max.)
g. M.O.A. Sand Filter: 2 feet
h. Effective Depth: 0.5 feet
i. Width: 5 feet
i. Minimum Length: 40 feet long
j. Effective absorption area: 200 ftZ
6901 Debarr Road, Suite 2B — Anchorage, AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246
5. ORENCO PACKAGE SYSTEM: The STEP tank with the Advantex Treatment System
will be manufactured by Anchorage Tank & Welding to meet the latest design criteria
established by Orenco Systems, Inc. The point of contact at Anchorage Tank is Lowell McNutt.
As with their standard STEP tank, it is equipped with a high water alarm per M.O.A
requirements.
6. SURFACE WATER: There is a creek 100 feet plus away that will be no concern to the
proposed septic system.
7. TOPOGRAPHY: As can be seen on the attached topography site plan, the proposed
drainfield is to be installed on a 20-30 percent slope. The contractor at the time of construction
will fill this slope in with fill to create a slope of less than 25 percent 50 feet downhill from the
proposed drainfield and 35 feet from the alternate site. Also there is a cutbank 50 feet plus from
the proposed drainfield and 38 feet from the alternate site. We request a 35 foot waiver from the
alternate site to this cutbank.
8. WAIVER TO IMPEARMEABLE SOILS: An impermeable layer was found at a depth of
5-6 feet in test hole #1 & #2. We are requesting that the vertical separation distance between the
bottom of the drainfield, and the impermeable soil layer, be waived to 4 feet. Justification for this
reduced separation distance is summarized as follows:
• The effluent being discharged to the drainfield is from an Advantex treatment system,
which has CBOD and TSS levels that are expected to be less than 10 mg1L. In addition,
the total nitrogen levels are expected to be less than the effluent from a lined Intermittent
Sand Filter (effluent from an ISF can be discharged into a drainfield that is only 4 feet
from bedrock and impermeable soils)
• There will still be a 4+ feet separation distance between the bottom of the drainfield and
groundwater
• There will be no discernable benefit (reduced BOD, TSS, or total nitrogen) achieved by
passing the effluent through 6 feet of soil vs. 4 feet of soil. It is generally agreed upon
that the pathogen reduction occurs within the first 4 feet of soil, hence the 4 feet required
separation distance to groundwater. It is reasonable to assume that by the time the
effluent passes through 4 feet of the insitu 30 & 3.33 minute per inch soil that the BOD
and TSS levels will be essentially zero (0). It is further assumed that there will be no
more reduction in total nitrogen achieved by building the mound several feet higher. The
highly treated effluent will probably not see further reduction in nitrogen levels without
introduction of a carbon source (as is the case with ISF effluent).
Based upon the facts presented we are requesting that the vertical separation distance between
the bottom of the proposed drainfield and an impermeable soil layer be reduced to 4 feet.
6901 Debarr Road, Suite 2B — Anchorage, AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246
9. CLOSING: I am open to any suggestions from your department that would be an
improvement to the proposed system. I am unaware of any negative impacts that this installation
would impose on adjacent wells, or septic systems. If you have any questions, please call us at
337-6179.
NOTE: Attached is a site plan drawing, a design drawing, an Advantex detail, a trench detail,
two soil logs, a topography site plan and a 7 page construction specification letter which are all
part of the design package for this septic system.
6901 Debarr Road, Suite 2B — Anchorage, AK 99504 — Ph: (907)337-6179 — Fax: (907)338-3246
P LAR T 232ASE VALLEYLOCC S/0 - +
LOT 29, BLOCK 4;
\ , / PARADIASE VALLEY S/D
LOT 30, BLOCK 4;
\\\ ,
PARADVALLEY S
44SE /D
�r
V�
r
Q
o! �
I
%
LOT 31, BLOCK 4;
PARADIASE VALLEY S/D
Com,
ALTERNATE
GaEa�e%
DRAINAGE
DITCH —
LOT 38, BLOCK 2;
PARADIASE VALLEY S/O
C�1)
LOT 37, BLOCK 2:
PARADIASE VALLEY S/D
1 3� TH
WW I
i Qp GaF PROPOS
O•GafF — 1 I WELL
�
TRACT E;
I
14o,
HILLSBORO S/D
LOT 28, BLOCK 4;
PARADIASE VALLEY S/D
I �C►S�`i
I
I
II HOUSE
I
I
I TRACT Ar;
I
A
'ter.
�-POTTER CREEK
' 6i
WW I
i Qp GaF PROPOS
O•GafF — 1 I WELL
�
GARAGE
II/
I
14o,
PROPOSED
I
I 4 BEDROOM
I
I
II HOUSE
I
I
I TRACT Ar;
I
A
I HILLSBORO S/D
' 6i
\\\
I
I
I
I
I
1 �
PROPOSED SEPTIC SYSTEM
!(SEE DESIGN PACE 2 OF 4).
� a 100' WELL RADIUS _ I
I I
i 1 LOT 3, BLOCK 3:
PARADIASE VALLEY S/D
LOT 2, BLOCK 3•—
PARADIASE VALLEY 5/D
TRACT D;
HILLSBORO S/D
' ^ I
4/24/2003
DRAWN BY: �: I �• ., (1�tiFll
ALASKA WATER & WASTEWATER Z.T.G.>, 4,
CONSULTANTS, INC. SCALE: , : I
..... .. .. .. ..............
_
6901 DFRARR ROAD. SUITF 2R • ANCHORAGF. AK 99S06 • PHONF (907)337.6179 • FAX (907)338-3266 1 — 00 iA
PREPARED FOR PHONE NUMBER: PAGE NUMBER: v�
MIKE CANNATA 301-0754 1 OF 4 �Q� of a Ga ess:
LEGAL DESCRIPTION: y4M1,10� 7953 e`<
LOT 1. BLOCK 3; PARADISE VALLEY SUBDIVSION
TYPE of WORK:
e,eio�o�=-�`��'''
SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM I ;;
1LTERNATE SITE WILL
REQUIRE WAIVER TO
CUTBANK :
1
ROXIMATE ocAnoN
OF C/BAN
ALL FOUNDAI
CLEANOUT
rHil
THd /
NOTE: THE 100 FEET CREEK SETBACK
AND SOUTH PROPERTY LINE ARE TO
BE FLAGGED AND STAKED BY A
REGISTERED LAND SURVEYOR PRIOR TO
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
6901 OFRARR ROAD. SUITE IR • ANCHORAGF. AK 99504 • PHONF (907)337-6179 • FAX (907)339.374
PREPARED FOR: PHONE NUMBER:
MIKE CANNATA 301-0754
LEGAL DESCRIPTION:
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3
TYPE OF WORK:
PROPOSED WELL AND SEPTIC SYSTEM LOCATION
4/24/2003 =§31 F
DRAWN BY:
Z.T.G.
SCALE: {r �: • ••�
1" = 40. .. .............
PAGE NUMBER:
2 OF 4 f yA.G nes.-
Q �J C 7953 rPG
e
I/
,TALL DOUBLE
CLEANOUTSAr
PRpP R'OpM
G
iT8jr
/ PROPOSED 1500 GALLON
ADVANTEX TREATMENT SYSTEM
(SEE DETAIL/PACE 3 OF 4)
\
`PROPOSED DRAINnELD/ EXCAVATE A TRENCH
THAT IS 3 FEET DEEP MAXIMUM BY 5 FEET WIDE
13Y 40 FEET LONG. ADD 2 FEET OF M.O.A.
APPROVED SAND FILTER AND THEN ADD 0.5
FEET OF CLEAN, WASHED SEWER DRAINROCK.
(SEE TRENCH DETAIL ON PACE 4 OF 4)
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
6901 OFRARR ROAD. SUITE IR • ANCHORAGF. AK 99504 • PHONF (907)337-6179 • FAX (907)339.374
PREPARED FOR: PHONE NUMBER:
MIKE CANNATA 301-0754
LEGAL DESCRIPTION:
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3
TYPE OF WORK:
PROPOSED WELL AND SEPTIC SYSTEM LOCATION
4/24/2003 =§31 F
DRAWN BY:
Z.T.G.
SCALE: {r �: • ••�
1" = 40. .. .............
PAGE NUMBER:
2 OF 4 f yA.G nes.-
Q �J C 7953 rPG
e
AdvanTex( Treatment System
AX20 -Mode 1a
�" b;
��+'o
FE�HAS TME°SS'
ADVANTEX MANUAL
N TO BE
NOTE: THE INSTALLED OVER THHEISEPTIC TANK k 4'
TBHE ADVANTEX FILTER.EYOND ON ALL SIDESTH EXCEPT UALLLOW
40x94Pod
~�
FOR HEAT TO ESCAPE FROM TANK &
RISE TO THE FILTER ABOVE R.
INLET.
6' JIM CAP
FINAL GRADE C".2)
30 INCH
INSULATED
6' PVC PUMP -OUT ,..!
(rM.2)� f{I
6' PVC COUPLING
ii
I
CLUED TO TANK
(TYP.2) 1
E
SEWER
— q QbaeROCK
_INLET `
I(
I ,
I) I I I I i hil 1
1 1LN
_ _I
_ II
eloT�UeE
OPTIONAL I I I I
SCREENED
VAULT
SLIDE SECTION 4 B E D R O O M
OF 6' PIPE
MR THIS CONNECTION ADVANTEX
ORENCO
TO PROTIDE
SHEER PROTECTION-
SYSTEM
I
EFFLUENT
EXTEND
E D T II II I I
PUMP
BRIDGE EXI
UFTSTATION
DATE: oppQpOp
4/24/2003 o pF q
t - DRAWN BY: O 0�
.ALASKA WATER & WASTEWATER Z.T.G.
CONSULTANTS. INC. SCALE. "' 4 N.T.S. " I ""' ' ��
6001 DFRARR ROAD. SUITE 28 • ANCHORAGE. AK 00504 • PHONF (007)337-6170 • FAX (007)339-3266 N.T.S.
PREPARED FOR: PHONE NUMBER: PAGE NUMBER:
MIKE CANNATA (907) 301-0754 3 OF 4 QQ •,Jef r A Ga a s.:
LEGAL DESCRIPTION: Q — 953 e0
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3 004�e q�.�vv
TYPE OF WORK: 400O'p\
e661o�0
DETAIL OF ADVANTEX TREATMENT SYSTEM �40pp000O
40 FEET LONG
--------------------
CO
5 FEET ICO
WIDE I
_FROM
OMT MTO-f
L---------------------------------------------�
ADVANTEX
TREATMENT
SYSTEM
FILTER FAB
INSTALL STAKING AND
BRACING AS NEEDED
5 FEET WIDE
ALASKA WATER & WASTEWATER
CONSULTANTS, INC.
6901 DFRARR ROAD. SUITE 28 • ANCHORAGE. AK 99504 • PHONE (907)137-0179 • FAX (907)338-324
PREPARED FOR: PHONE NUMBER:
MIKE CANNATA (907) 301-0754
LEGAL DESCRIPTION:
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3
TYPE OF WORK:
DETAIL DRAWING OF PROPOSED DRAINFIELD
.5 FEET OF
EFFECTIVE
'24/2003 0
1 BY: t
Z.T.G. o �P
o
N.T.S. �...:...
NUMBER: 0
4 OF 4 0. .16
i FEET DEEP
MAXIMUM AT
ANY POINT
7953
��ro f e a atod4o
• 4
ALASKA WATER & WASTEWATER
CONSULTANTS, INC. 0ak
99QO
901 DEWR PGD. WORE 2a AMMORA
• DE. AK. 304 • PMOME• 907—!179 • FAX: 3240 • 17 WM- we m ....: • . .. .. • • • • • • • • • • • • . • .
6
SOIL LOG - PERCOLATION TEST ,
LEGAL DESCRIPTION: PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3 OQ e e A. Go ness!
PERFORMED FOR: MIKE CANNATA DATE 4/8/2003 QQ�% —7953 `cpaQ
DfEPTH — (PAGE 1 OF 2) �40�df'rofeaato�°o��
1
ORGANICS TEST HOLE 1 D00000�a
SOIL CLASSIFICATIONS
2 � �
?dl 4R GW ORG
3 GP ML
GM CL
4 MSL
GC OL ,
GM/CL %
°• • ° o SW MH
5 SP CH
SM OH
6 SC /
7DEPTH TO
nat _
8— THI
•yyf 'r' f
i SITE PLAN
10
11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP
SAND LENSES
12
13
14
15
16
17 B.O.tI.
18
19 PERCOLATION RATE 1.9 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 1.0 FT. AND 1.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISHER
COMMENTS:
PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS 1 &PFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
GROUNDWATER
DATE
DRY
4/8/2003
DRY
4/15/2003
4/9/2003
1
3:01
—
TIME
(MINUTES)
READING
(INCHES)
4/9/2003
1
3:01
—
6`
—
2
3:11
10
1`
5"
3
3:12
—
6`
—
4
3:22
10
1`
5`
5
3:35
—
6"
—
6
3:45
10
3 4"
5 1 4"
7
3:46
—
6`
—
8
3:56
10
3 4"
5 1 4`
9
3:56
—
6`
—
10
4:06
10
3 4`
11
4:07
—
6`
—
12
4:17
10
3 4`
1
3:02
-
6`
-
2
3:32
ALASKA WATER & WASTEWATER
6"
X00
CONSULTANTS, INC.
.
.............
'
• MOWL ' • AX. • okn"c.00m
SOIL LOG — PERCOLATION TEST
LEGAL DESCRIPTION:
PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3,
Q .J f y ."G*
rness p
PERFORMED FOR:
MIKE CANNATA DATE: 4/8/2003
QO°v CE -79
(PAGE 2 OF 2)
�0°''°yp
(feet)
TEST HOLE #1
��0000�a��
t
SOIL CLASSIFICATIONS
2
;as GW ORG
3
a &re:i�_ GP ML
C�1
GM CL
q
W
GC OL
0
SW MH
I
5
SP CH SEE
H
SITE PLAN
ON
Sc PAGE 1 OF 2
6
W
7
<
GROUNDWEPTH ATER DATE
e
Z
s
p
10
Q
11
U
LL.
DATE READING CLOCK NET TIME
WATER LEVEL
NET DROP
TIME (MINUTES)
READING
(INCHES)
12
(J)
4/9/2003
13
U
14
(/•)
J
15
0
�
16
W
17
W
V)
16
19
PERCOLATION RATE 120+ (MIN./INCH) PERC. HOLE DIA.
6 (INCHES)
TEST RUN BETWEEN 7.0 FT. AND 7.5
FT.
20
A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO
SOILS LOGGED BY:
JODY MAUS PERCOLATION TEST PERFORMED BY:
MATT FISHER
COMMENTS:
PERFORMED
BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W P RFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
1
3:02
-
6`
-
2
3:32
30
6"
0`
ALASKA WATER & WASTEWATER
CONSULTANTS, INC. *�*O�Q
........ . .................0
1901 DEMM AW. su1E 29 • ANCHONAOG AK. 99304 • 7'NONE (907)M7-6179 • FAX. (907)335-U46 • wowm* okwc.com
SOIL LOG — PERCOLATION TEST ..••.•...•.
LEGAL DESCRIPTION: PARADISE VALLEY SUBDIVISION; LOT 1, BLOCK 3 QO e e A. Garness!
PERFORMED FOR: MIKE CANNATA DATE: 4�g�Q003 �� o, C -7953 `IvA
�Op
DE - - 44�Dedpro(e5slo��&
(feet)ORGANICS ITEST HOLE #21�OO00000�
SOIL CLASSIFICATIONS
2
I
GW - ORG
/
3 GP MLSM/MLGM CLMIXED W/4GM/CL GC OLSW MH5 SP CH /
SM OH6 SC
7
7DEPTH TO DATE TH1-
8
CLAY w/ I f
9 SAND LENSES ; SITE PLAN
1 1 "=100'
1
10
11 DATE READING CLOCK NET TIME WATER LEVEL NET DROP
12 B.O.H.
13
14
15
16
17
18 12 4:05 10 1" 50
19 PERCOLATION RATE 2 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN 1.0 FT. AND 1.5 FT.
20 A FOUR HOUR PRESOAK WAS PERFORMED: N YES ❑ NO
SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: MATT FISHER
COMMENTS:
PERFORMED BY AKWWC, INC. I, JEFFREY A. GARNESS, CERTIFY THAT THIS W P FORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE:
GROUNDWATER
DRY
4/6/2003
DRY
4/15/2003
4/9/2003
1
3:00
-
TIME
(MINUTES)
READING
(INCHES)
4/9/2003
1
3:00
-
6"
-
2
3:10
10
1 1 4"
4 3 4`
3
3:11
-
6"
-
4
3:21
10
1 1 4`
4 3 4"
5
3:23
-
6"
-
6
3:33
10
1 1 4`
4 3 4"
7
3:34
-
6"
-
8
3:44
1D
1"
5`
9
3:45
-
6"
-
10
3:55
10
1"
5`
11
3;55
-
6"
-
MUNICIPALITY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Parcel I.D. 020-421-09
Certificate of On -Site Systems Approval
Expiration Date: 5/31/23
Legal description PARADISE VALLEY BLK 3 LT 1
Site address 18531 PORTUGAL PL Anchoraqe AK 99516
Current property owner(s) NICHOLS KRYSTAL & JACOB
hew
The On-site system(s) is/are approved for q bedrooms x/23
X Conditional approval for 4 bedrooms, with the following stipulations:
Comments or advisories: Conditional requirements to be completed by May 15, 2023:
1. Electrical line for well -to be buried.- - oma, -
C D(efie _ _
2. Advantex pod to be repair/replaced as neccessary. ad�r-s!�-A
',f ron��
s I�C�se. pr
7��1-Icldli'� arc /Iof' wafer, fiJcht ahYAiore-
By
:—Lz Original Certificate Date: 3/9/23
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist x
Absorption Field Advisory
Tank Age Advisory
Other
Well Flow Advisory
Nitrate Advisory
Arsenic Advisory
COSA Approval_June 2022
e-0 SA
MUNICIPAUTY OF ANCHORAGE
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 020-421-09
Complete legal description PARADISE VALLEY; BLOCK 3, LOT 1
Location (site address) 18531 Portugal Place * Anchorage, AK
Current property owner(s) Jacob and Krystal Nichols
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
Day phone 907-244-6011
3. TYPE OF WATER SUPPLY: 0 Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units ❑ Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: 0 Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ■❑ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age 16 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: W AWWTS ❑ Bed ❑ Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ Waiver Fee $
Date of Payment Date of Payment
COSA # 0 5 C �Z_�3 l03 Waiver #
COSA Application June 2022
/Im
COSA Checklist
Legal Description: PARADISE VALLEY; BLOCK 3, LOT 1
V'A IZZ
Parcel ID: 020-421-09 (0
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system
A. WELL DATA
0 Well log is filed with Onsite (or attached)
Well production at time of test 5.9+ gpm
Date drilled 7/17/2003 Total depth 229 ft
Water storage tank volume NIA gallons
Cased to 229 ft
Well disinfected for coliform test? ❑ Yes W No
9 Sanitary seal is functioning correctly
N■ Coliform bacteria is Negative
❑ Wires are properly protected
Nitrate mg/L ❑■ Nitrate less than MRL (ND)
Casing height (above ground) 18+ in.
Arsenic 6.06 ug/L ❑ Arsenic less than MRL (ND)
Date of flow test for COSA 5/20/2022
Collected by GEG, LTD.
Static water level at beginning of test 141.4 ft.
Date 5/20/2022 & 2/6/2023
Comments WELL WIRES ARE EXPOSED - SEE ATTACHED QUOTE FOR REPAIRS (THIS IS A CONDITIONAL COSA)
40141a —Tv WFiLL
B. TANK DATA
Measured operating fluid level in septic tank
Date of pumping
PMequired maintenance completed, if AWWTS
Comments: "SEE MAINTENANCE REPORT
O
op D. ABSORPTION FIELD DATA
Which system tested (date installed) 2006
Z ❑■ ALL standpipes present per record drawing
Total measured depth from grade 2.5 ft (max)
Measured depth to pipe invert from grade - ft (min)
Q N/A — pressurized field.
Per recorI drawings, field=effective.
d.
❑� Monitor tubes go to bottom of
N0
If not, state depth into effective P Q6P
11ZElPresoaked required if I N I
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced N/A gallons - date
Any rejuvenation treatment (past 12 months) NO
If yes, enter date N/A
C. LIFT STATION
❑■ Required maintenance completed
Age of lift station 16 years
Lift station material STEEL
Comments:
Adequacy test date 5/20/2022
Results [E Pass
Fluid depth prior to test 0 in
Water added 605 gal
New fluid depth 1 in
Elapsed time 20 min
Final fluid depth 0 in
Absorption rate 600+ gpd
FIELD STATUS — POST RECOVERY
Effective depth (per record drawings) 6 in
Effective depth used 0 in
Effective depth remaining 6 in
Comments/Deficiencies: ALL WATER INTRODUCED THROUGH PUMP VAULT. APPROXIMATLEY ONLY 20.5' SOIL
COVER OVER SHALLOWEST PORTION OF DRAINFIELD. SEE EMAIL REGARDING NO FREEZING.
COSA Checklist June 2022
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100' Community Sewer Manhole/Cleanout > 100'
❑Yes if No *50+ ft ❑■ Yes if No ft
Neighboring Tank > 100' ❑i Yes if No ft
Absorption Field on Lot > 100' ❑ Yes if No *50+ ftl
Private Sewer/Septic Line >.25' QYes if No ft
Holding Tank > 100' g Yes if No ft
Neighboring Absorption Fields > 100' Animal Containment > 50' Q Yes if No ft
❑■ Yes if No ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ❑■ Yes if No ft ❑i Yes if No ft
❑ N/A — Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorptio Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ❑■ Yes if No ft Surface Water > 100' ❑ Yes if No 50+ ft
Tank to Property Line > 5' ❑n Yes if No ft
Field to Property Line > 10' Q Yes if No ft
Water Main > 10' 0 Yes if No ft
Water Service Line > 10' [j] Yes if No ft
Wells on Adjacent Lots
Private Wells > 100' ❑ Yes if No *50+ ft
Community Wells > 200' ❑■ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER'S COMMENTS
*AWWTS **STEP TANK IS 5'+ FROM BUILDING FOUNDATION. MET CODE AT TIME OF INSTALLATION
**STEP TANK AND PUMP VAULT ARE AT THE TOE OF A LARGE RETAINING WALL. THIS WAS INSPECTED BY THE MOA IN THE PAST.
INSTALLATION OF NEW DRAINFIELD WOULD LIKELY REQUIRE ACCESS THROUGH LOTS TO THE SOUTH OR EAST
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Garness Enoineering Group, LTD. (GEG) Phone 907-337-6179
Engineer's Printed Name Jeffrey A. Garness Date 2 IS/23
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in
accordance with the guidelines and regulations established by the Municipality of Anchorage and industry
practices. The reported results describe the condition of the system/s on the date/s of the evaluation.
Separation distances were measured to readily identifiable features. Hidden defects or encroachments may
exist that were not identified during the evaluation. The operational life of all wells and septic systems depend
upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate
during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing
the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not
guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regarding
the future performance of the well or septic system. GEG makes no representation whether an alternative well
or septic system can be installed on the property in the event either of the current systems fail to perform
adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG
to perform the evaluation. Reliance upon the information provided in this report by any other person or party
(including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever.
COSA Checklist—June 2022
;WE (CM
I
Wockenfuss, Deborah M.
From: Sterling Anderson <sterling@aplusak.com>
Sent: Tuesday, May 16, 2023 6:59 PM
To: Wockenfuss, Deborah M.; Gregg Dunlap; David Garness
Subject: 18531 Portugal Place
Attachments: Inspection_Portugal jpg; IMG_0681.JPEG; IMG_0682.JPEG
Follow Up Flag: Follow up
Flag Status: Flagged
[EXTERNAL EMAIL]
Deborah,
Attached is an annual inspection sheet from my inspection on 5/11/23. From my inspection there is cosmetic damage to
the pod flange that interfaces with the lid. The flange has two cracks from the right side end being pushed inwards. This
right side indention only effects the right gas shock that supports the lid. The shock was removed to allow the lid to open
and close freely. The lid will stay open with only the left shock. The lid does close and seal securely. No leaking is present
from inside out when running the recirculating pump and no leaking is present from outside the pod to the inside. The
bottom of the pod is clean and free of fluid. In my professional opinion the damage to this pod is purely cosmetic and
this AX20 Pod can easily last a lifetime.
I spoke with David at Garness he is willing to sign our inspection sheet as Garness doesn't service Advantex systems A+
Home Service is the service provider for these systems. Let me know if you need anything else we will be burying the
well electrical tomorrow.
Sincerely,
Sterling Anderson
A+ Home Services
Sterling(@aplusal<.com
(907) 268-9674
www.apiusak.com
Project No. 111636-001- Geotech Report - 18531 Portugal Place
5430 Fairbanks Street Suite 3 Anchorage, Alaska 99518-1263 907 561-2120 Fax 206 695-6777
www.shannonwilson.com
June 2, 2023
Gregg Dunlap
Keller Williams Realty Alaska Group
101 West Benson, Number 101
Anchorage, Alaska 99903
RE: GEOTECHNICAL REPORT, 18531 PORTUGAL PLACE, ANCHORAGE, ALASKA
Dear Mr. Dunlap:
This letter report presents the findings of our geotechnical evaluation for the existing on-site
wastewater treatment system at 18531 Portugal Place in Anchorage, Alaska. We understand
that the property has been recently sold and that funds are currently being held in escrow
pending the resolution of concerns regarding apparent damage to the treatment system.
The Municipality of Anchorage (MOA) has expressed concerns regarding a recent
inspection of the system which revealed damage to one of its components. The MOA has
requested that a geotechnical engineer observe the damage and provide an opinion
regarding the cause of the damage prior to issuing a Certificate of On-Site Systems
Approval (COSA) which would release the escrow funds to the seller that are currently
being held.
SITE VISIT AND OBSERVATIONS
On May 30, 2023, Shannon & Wilson mobilized an experienced geotechnical engineer from
our Anchorage office (Mr. Kyle Brennan) to observe the site conditions. While on site, we
observed exposed portions of the system and the ground surface/topography around the
system. Based on our conversations with you and observations at the site, the system
consists of an AdvantTex treatment system by Orenco Systems. The system incudes a large
underground tank that collects wastewater from the residence and recirculates the liquid
effluent from the tank through a filter pod that rests above the tank. The filter pod at the
subject residence is approximately 6 feet long by 2 feet wide, with the long axis of the pod
oriented roughly east-west. During our site visit, we opened the pod lid and observed that
the pod chamber was roughly 3 feet deep. The east end of the pod exhibited inward flexing
and minor cracking along the rim. Cracking did not appear to propagate down the side of
Gregg Dunlap Keller Williams Realty Alaska Group
June 2, 2023
Page 2 of 4
Geotech Report - 18531 Portugal Place Project No. 110604-001
the pod more than an inch or two. Similar flexing, albeit with less total deflection and no
cracking, was observed on the west end of the pod. It appeared that deflections on the pod
sides were greater at the ground surface than deeper on the pod walls. Flexing was not
observed on the north or south ends of the pod. The exterior of the pod is surrounded by
vertical blueboard insulation.
The system is located on the north end of the residence driveway where the grade is
approximately 2 feet above the driveway grade. Landscaping on the north and east sides of
the pod consist of large rock and gabion retaining structures. The ground immediately
around the portions of the system exposed at the surface is flat, extending at least 4 to 5 feet
in all directions. Beyond this distance on the north and east sides of the system, the ground
slopes up at approximately 1 horizontal (H) to 1 vertical (V) to the base of a gabion retaining
wall that is roughly 15 feet from the system on the north side and greater than 30 feet on the
east side. The gabion wall on the east side of the system shows significant signs of internal
instability, but the portion of the wall closest to the system on the north side appears to be
relatively stable.
Soil borings were not conducted or reviewed for our evaluation, however, based on our
experience in the area, the native soil conditions likely consist of relatively dense materials
of glacial origin and bedrock may be present within approximately 20 to 30 feet of the
ground surface. The soils in which the system is embedded likely consist of imported fill or
soils sourced from on-site to backfill around the system components. At the time of our site
visit there were no obvious signs of surface subsidence and/or settlement suggesting that
the soils were placed and compacted with moisture/density control around the system
during construction.
CONCLUSIONS
Based on our observations on site, it is our opinion that the damage observed in the system
pod is likely due to shallow lateral earth pressure and seasonal ice pressure from soils
immediately around the pod walls. We do not believe that the apparent instabilities in the
retaining walls and slopes east of the system are directly related to the observed pod
damage. We believe that fill placement and compaction during construction of the system
likely imparted horizontal loads on the pod walls which would have caused some minor
Gregg Dunlap Keller Williams Realty Alaska Group
June 2, 2023
Page 3 of 4
Geotech Report - 18531 Portugal Place Project No. 110604-001
flexing. Due to the topography around the pod, it appears that surface drainage likely
collects around the pod and during winter months ice wedges likely form around the pod
walls. Seasonal development of these ice lenses have likely caused increased lateral
pressures on the pod walls and progressive displacement/flexing and subsequent cracking.
If left as is, we anticipate that it will be possible for continued deflection and cracking to
progress on the system’s pod feature. Seasonal frost action could cause progressive
development of this damage, but it is not possible to definitively estimate how long it will
take for the damage to progress to a point where the system will need replacement.
Improvements to the site drainage and backfill material around the pod could be
undertaken to reduce the effects of seasonal frost on the system’s shallow components.
Development of such recommendations are outside of the scope of our services, but can be
provided for additional fee if desired.
It should be noted that a detailed evaluation of the slopes and retaining walls above the
system was not performed by Shannon & Wilson. However, the distress observed on site,
appeared to be related to internal stability of the wall and not related to larger scale
foundation issues under and in front of the wall. That said, if a larger scale failure of the
retaining wall and/or slopes around the site is experienced, damages to the system could
occur. However, given the proximity of the residential structure and other site features, the
damages to the onsite septic system would be relatively minor in comparison to the other
damages to the site that would occur.
CLOSURE AND LIMITATIONS
This report was prepared for the exclusive use of our client and their representatives for
evaluating the site as it relates to the geotechnical aspects discussed herein. The conclusions
and interpretation contained in this report are based on site conditions as they are inferred
from existing information and as described herein. Actual conditions may vary significantly
which may influence system performance.
Unanticipated soil conditions are commonly encountered and cannot fully be determined
by reviewing existing information and observing surface conditions. Such unexpected
conditions frequently require that additional expenditures be made to attain a properly
Gregg Dunlap
Keller Williams Realty Alaska Group
June 2, 2023
Page 4 of 4
constructed project. Therefore, some contingency fund is recommended to accommodate
such potential extra costs. Please read the Important Information section at the back of this
report to reduce your project risks.
Copies of documents that may be relied upon by our client are limited to the printed copies
(also known as hard copies) that are signed or sealed by Shannon & Wilson with a wet, blue
ink signature. Files provided in electronic media format are furnished solely for the
convenience of the client. Any conclusion or information obtained or derived from such
electronic files shall be at the user's sole risk. If there is a discrepancy between the electronic
files and the hard copies, or you question the authenticity of the report please contact us.
If you have questions or comments, please contact the undersigned. We appreciate the
opportunity to be of service to you.
Sincerely,
SHANNON & WILSON
...........
K 22
CE -111122
4l>� PROF€SVO
Kyle Brennan, PE
Vice President
Enc. Important Information About Your Geotechnical/Environmental Report
Project No. 110604-001
v
3
N
O
N
N
-�
Ltd
ENGINESALES-CONSULTING GROUP, � ��
ENGINEERING vas..,,..
March 7t" 2023
Municipality of Anchorage
Development Service Department
On -Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
Ref: Conditional COSA for Paradise Valley; Block 3, Lot 1
To whom it may concern:
The subject lot is under contract (for purchase), however, the Advantex trickling filter pod needs
to be replaced and the well wires are not in conduit. Attached is a quote from A+ Home Services
which shows the cost of replacing the AX20 pod and a quote by Precision General to bury the
well wires. We are requesting that your department issue a conditional COSA and allow the
work to be completed in spring. We feel there is minimal risk to public health and safety by
allowing the work to be completed in spring.
If you have any questions, please contact us at 337-6179. Thank you far your assistance.
3701 East Tudor Road, Suite 101 * Anchorage, Alaska 99507-1259
Phone: (907) 337-6179 * Fax: (907) 338-3246 * Website: www.garnessengineering.com
Sonja Blewett
From: Jacob Nichols <jakeandkris2012@hotmail.com>
Sent: Wednesday, February 15, 2023 10:47 AM
To: Sonja Blewett
Cc: Sherilynn Bare
Subject: Re: 18531 Portugal Place
Hi Sonja,
No freezing issues at all in the entire time we lived there.
Thanks!
Jacob
Get Outlook for iOS
From: Sonja Blewett <Sonja@garnessengineering.com>
Sent: Wednesday, February 15, 2023 2:01:38 PM
To: jakeandkris20l2@hotmaii.com <jakeandkris2012@hotmail.com>
Cc: Sherilynn Bare <sherilynnbare@mac.com>
Subject: 18531 Portugal Place
Hello, can you please confirm you have not had any freezing issues with your septic since you have lived there? The
Muni will want confirmation. Thanks!
Sincerely.
Sonja Blewett
Corporate Secretary/Treasurer
Garness Engineering Group, Ltd.
3701 E. Tudor Road, Suite 101
Anchorage, Alaska 99507
Phone: (907) 337-6179
Fax: (907) 338-3246
Website: www. garnessengineering com
GARNESS ENGINEERING GROUP, Ltd—
M3y_06.2022 03:43 PM A+
9078686770 P 6/ 7
Room
slim
■ ■RR a among
i Nunn r r
421474
�
Emma 5
Irl. ��
■
r son ■ NMN
� �Irla ■a� �n
son ■ ago
rr
Float Cando ...
an .. a
�
yarffexe Reid Maintenance Report
Annual Inspection
P-FartY9tmer/WstWw— R
Jacob & Krystal Nichols �-
18581 Portugal Place, AnchOrSgg AK 99516
AX 8Ha IDM County ID M Pod 0
AX -108932 SWO60165 208409
Retrieve O&M Info
Bally itaw
Timor aoWngs:
Perform Plaid Sampling/Observations
NTU (16 s NTua) pN (6-9) DO (2-6)
Odor of Sample
Typical Musty n Earthy Q Moldy
Non-tyaleal sulfide Q Cabbn9a ❑ 1?ooay
OHy film In PNU ygs No
Foam In tank ©yes No
Cheok Control Panel
k0circ Amps Dislcha{rge Amps
Audibio and visual alamta Z'OK
Dial tone (telemetry only) n yes /ZNo
InsPect/Clean Pump System
Comments
01*ndar
Larry Batts
RTU RAIL 4
RTLj107968
Measure Sludge/Scum
Sludge
tat Compartmen- t 1„o„. \� provloue
2nd Compartment Current PraVl0U8
Inspect/Clean AdvanTex Filter
Anchoragerank
907-272-3543 ,
Contact Kvw
907-244-6011
Date of I act Innpaanon
06/02/2021
Scum
Currant Proviouo
Currant Previous
Odors I Inspect Clean
Normal n Punoant I-AtA✓Alp/prltlaoa
slomat;�Nono/mjnor
Normal ❑ Excessive Pod Bottom
Bridging/Ponding: ❑ Excessive I Intake Vent ]
InsPsct/Clean Discharge PUMP syetom
Inspect Inspect Clean
Risadtid Fib
SP11eo Box
Float cords Pump
Inspect/Senace Other System Components
Inspect Ctoan Inspect Clean
Disinfection Equipment
;Z �J Dispersal Latal`abtariflces
abaorvatlons
Additional Services Ran:iered
r❑ Cieatad textile sheets? C3 Rap laGed UV kgmgp
Jtq(t roFtaowy/UooU vurnr IttinaT
Pa�rts� used: w = warranty, B . Billable (✓ aPProprtats e9i9otion)
W 6 item Number Description
Final/$afety Inspection
RSV rolnstalled
Manifold reconnectod; flush valves closod
Summary/Recommendations
© 8yatom Performing; no further actlon needed ©,
Cali for cervico ria.
Date
Fax completed farm to 1-888-$84-7444
zea on
Panel reactivated
needs pWttpinp
Inspoct
clown
Sphco Box.....,,,,,,
Float Cando ...
Floats
Purnp ........... ...........
Blotuboa Flitor.................
Blotuhe Pump Vauh ............
Raclrculating Splittar Valva....
_
Comments
01*ndar
Larry Batts
RTU RAIL 4
RTLj107968
Measure Sludge/Scum
Sludge
tat Compartmen- t 1„o„. \� provloue
2nd Compartment Current PraVl0U8
Inspect/Clean AdvanTex Filter
Anchoragerank
907-272-3543 ,
Contact Kvw
907-244-6011
Date of I act Innpaanon
06/02/2021
Scum
Currant Proviouo
Currant Previous
Odors I Inspect Clean
Normal n Punoant I-AtA✓Alp/prltlaoa
slomat;�Nono/mjnor
Normal ❑ Excessive Pod Bottom
Bridging/Ponding: ❑ Excessive I Intake Vent ]
InsPsct/Clean Discharge PUMP syetom
Inspect Inspect Clean
Risadtid Fib
SP11eo Box
Float cords Pump
Inspect/Senace Other System Components
Inspect Ctoan Inspect Clean
Disinfection Equipment
;Z �J Dispersal Latal`abtariflces
abaorvatlons
Additional Services Ran:iered
r❑ Cieatad textile sheets? C3 Rap laGed UV kgmgp
Jtq(t roFtaowy/UooU vurnr IttinaT
Pa�rts� used: w = warranty, B . Billable (✓ aPProprtats e9i9otion)
W 6 item Number Description
Final/$afety Inspection
RSV rolnstalled
Manifold reconnectod; flush valves closod
Summary/Recommendations
© 8yatom Performing; no further actlon needed ©,
Cali for cervico ria.
Date
Fax completed farm to 1-888-$84-7444
zea on
Panel reactivated
needs pWttpinp
473 525
© i-fax.comFax completed form to 1-866-384-7404
Unscheduled
Property Owner/Tracking #Operator
Site Address Contact Phone
AX Site ID # County ID # Pod # RTU #/UL # Date of Last Inspection
Dispatcher Comments
Date: ________________________ Time: ______________
Notifi cation of site condition
Made by VeriComm® Monitoring System
Made by Homeowner
Other __________________________________________
Site condition at time of call
Alarm Tank Overfl ow
Odor Sewage Backup
Other __________________________________________
Field Sampling/Observations
Necessary Not necessary
NTU (15 ± NTUs) pH (6-9)DO (2-6)
Odor of Sample.
Typical Musty Earthy Moldy
Non-typical Sulfi de Cabbage Decay
Conditions at site
Alarm On Yes No
(If yes, alarm type ______________________________ )
Tank Liquid Level Normal High Low
Pump Operational? Yes No
Circuit Breakers
Recirc . . . . . . . . Tripped On Off
Discharge . . . . . Tripped On Off
Controls . . . . . . Tripped On Off
VCOM® ATRTU Board: (if applicable)
Document the panel status by shading the appropriate
inputs and outputs as indicated by the yellow and red LEDs.
Inputs 1 2 3 4 5 6 7 8
Outputs 1 2 3 4
Power
(Green LED)
On Off Flashing
Cause of Malfunction: Mechanical Process-Related
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
Services Rendered:
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
__________________________________________________________________________________
Parts Used: W = Warranty, B = Billable (✓ appropriate selection)
W B Item Number Description
Notes/Final Recommendations:
System performing; no further action needed Additional service needed
__________________________________________________________________________________
__________________________________________________________________________________
Final/Safety Inspection:
Lids bolted on? Yes No
(If damaged, comment _________________________________________________________)
Control Panel reactivated? Yes No
Circuit Breakers:
Recirc: On Off Discharge: On Off Controls: On Off
Time at Site Travel Time Total Time
Signature ________________________________________________________________________
Date ________________________________________Time _______________________________
Field Maintenance ReportAdvanTex®AdvanTex ®
Treatment Systems
Site visit to assess AX filter pod riser lids damage.
Snow was cleared from pod lid and no visible damage reported.
Due to heavy frost, the tech was not able to open the lid.
x Our records indicate that previous damage to riser lids (recirc
and pump basin)were repaired. Our records also indicate that
theres was damage to the filter pod consisting of cracks that may
or may not be repaired at this time. The AX pod does not appear
to be leaking it also appears to be a good seal on the lid.
See attached pictures.
x
Future repairs on AX filter pod may be required.
X
3/1/2023 12:30 PM
Jeff Garness
From: Tom Varney <tom@anchoragetank.com>
Sent: Wednesday, May 11, 2022 8:45 AM
To: Jeff Garness
Cc: Erik Widger; Sonja Blewett; David Garness
Subject: RE: Advantex Inspection Report
Attachments: 18531 Portugal 2022 Inspection.pdf; IMG_0063 jpg; IMG_0062 jpg; IMG_0060 jpg
Everyone,
This system has been plagued since day one as the rocky hillside continues to throw boulders at the system and anyone
who approaches it.
Larry conducted the 2022 Annual Inspection last Thursday and took the attached photos.
IMG 60: A boulder slid towards the Discharge Pump Basin a few years ago. That lateral movement sheared the insulation
off the bottom of the lid. The basin cannot seal properly as long as the boulder remains in position.
IMG 62: The lateral movement of the hillside has bent in the wall of the AX20 pod inward so much that the manifold
snapped. The blue glue you see in the corner of the pod is Larry's piping repair. With the manifold break in that position
water simply poured into that portion of the filter fabrics — which explains the nasty goo pileup. That has been cleaned
away.
IMG 63: This is a closeup of the pod wall at the bending point. It's hard to determine if the wall has cracked. There is the
potential of a pod replacement and the unit itself (insulated) is north of $5000.
The seller has been reluctant to remove boulders or to provide a means for remote monitoring for the past nine years so
we feel it's in the best interest to fully disclose these discoveries before another homeowner purchases this potential
problem.
Tom Varney
AdvanTex Coordinator
Anchorage Tank
2723 Rampart Drive
Anchorage, AK 99501
907-343-3704
anchoragetank. com
T" MCIPALITY OF ANCHORAGE
! i 'IMM 1
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this 1- Day of of 20R3 , by and between
a� r\ , herein the —OWNER," and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC)15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as &ayNA Q,/, Sec_Sys�&m
located at (legal description)
0
2. Maintenance. Repairs and Alterations.
(Owner is required to read, understand and initial each section)
Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the Municipality.
It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
'4vv AD includes an annual maintenance fee (typically $400 to $600).
1W11" n Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
40 repairs
Owner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05118/2018) Page 1 of 3
Scanned with CamScanner
.& Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
DOwner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
(C 0 Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
OOwner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
� D Owner agrees that the AWWTS installation and maintenance requirements as provided
by the AWWTS vendor/installer and approved by the Municipality are the governing
guidelines for the construction, maintenance and repair of the Owner's AWWTS.
Owner agrees to maintain remote monitoring of the AWWTS as required by the
AWWTS approval.
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability, Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
Scanned with CamScanner
4OV15/2,0,2-3
OWNER:
fiI �A By: (signature) Date: a 15
A"6r ?M y (print name)
N ew fork
STATE OFA )
H c,SSc� C ) ss.
T )
The foregoin instrument was acknowledged before me this 5 day of )-ekw
20_Z3, by —I
NOTARY PUBLIC FORAL�TSKA ti's- TALITHA ROBINSON
My Commission expires: NOTARY PUBLIC, STATE OF NEW YORK
Registration No. 01 806398203
Ouatified in Nassau County
MY Commission Expires September 23.2023
LITY•
(signature) Date:
t nam Title:
4,xv-)
(rev. 05/18/2018)
Page 3 of 3
Scanned with CamScanner
Municipality of Anchorage
On -Site Water & Wastewater Program
(907)343-7904
CERTIFICATE OF ON—SITE SYSTEMS APPROVAL
Parcel I.D. 020-421-09 Expiration Date: B —,2 � `
1. GENERAL INFORMATION
Complete legal description PARADISE VALLEY S/D; BLOCK 3, LOT 1
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
18531 PORTUGAL PLACE, ANCHORAGE, AK, 99516
AARON & KRISTINA HAYNES Day phone
18531 PORTUGAL PLACE, ANCHORAGE, AK, 99516
BOB BAER W/ REMAX/DYNAMIC Day phone
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 4
4. TYPE OF WATER SUPPLY:
C/O AGENT
727-6205
TYPE OF WASTEWATER DISPOSAL:
Individual Well
IN
Individual On-site
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
WaiverNariance
Received
COSA to be released to the
unless otherwise requested by the engineer.
COSA Fee $ f✓7_<0/ `
Date of Payment ! I g l
Receipt Number 05w, G
COSA# 05cI'fIga
Date: el / 2 3 /14
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
Distance:
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm
Address
GARNESS ENGINEERING GROUP, Ltd.
3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK, 99507
Engineer's Printed Name
Engineer's Comments:
JEFFREY A. GARNESS, P.E.
In conducting this evaluation, GEG, LID. attempted to provide a thorough,
conscientious engmeeting analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the throe of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
6. DSD SIGNATURE
AzSystem #1 Approved for bedrooms.
System #2 Approved for bedrooms.
Disapproved.
Phone
337-6179
Date i 117 )q
G
Conditional approval for bedrooms, with the following stipulations:
�ffrdy A 6arndss =moi
C7-79 3
'•. 7 f ; l•••'• •CcC��1
f'ROFESSt��i•�•
alut1% �
tDFr(�YCy(t�
O%
�= ON-SITE
WATER AND
C WASTEWATER oz
J
�
PROGRAM
Original Certificate Date: _ 7 _.1_) -3 _ / 41
The'ciltlity✓or�(Defiorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the represe atations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTCHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
1p— mn>roi
Nitrate Advisory
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist *_of
Structure served by this system _
Certificate of On -Site Systems Approval Checklist
Legal Description: PARADISE VALLEY S/D; BLOCK 3, LOT 1
Parcel ID: 020-42-109_
A. WELL DATA
Well type PRIVATE If A, B, or C provide PWSID# N/A
Date completed 7/17/2003 Sanitary seal (Y/N)--Y---
Total depth 229 ft.
Date of test
Static water level
Well production
Cased to 229 ft.
FROM WELL LOG
7/17/2003
151 ft.
20
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 ml.
Arsenic: ND ug./L.
B. SEPTIC/HOLDING TANK DATA
Nitrate ND mg./L.
Date of sample: 9/3/2014
ADVANTEX SYSTEM
Well Log (Y/N) YES
Wires properly protected (Y/N) YES
Casing height (above ground) 18+ in.
AT INSPECTION
9/11/2014
142
5.85+
gP.M.
Collected by: GEG, Ltd.
Tank Type/Material S.T.E.P./STEEL Date installed 10/12-11/3/2006
Tank size 1500 gal. Number of Compartments 2 Cleanouts (Y/N) YES
Foundation cleanout (YIN) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES
Date of pumping Pumper ADVANCED TREATMENT SYSTEM
C. ABSORPTION FIELD DATA
'BELOW EXISTING GRADE
Date installed 10/12-11/3/2006 Soil ratingp.d./ rft'bdrm 3.0
)— System type SHALLOW TRENCH
Length 40 ft. Width 5 ft. Gravel below pipe 0.6 ft.
Total depth '2.7-2.9 ft. Eff. absorption area200+ ft2 Monitoringtube YES
Depression over field NO
Date of adequacy test "9/11/2014 Results (Pass/Fail) PASS
For a bedrooms
Fluid depth in absorption field before test E in. Water added 600 gal. New depth E in.
Elapsed Time: = min. Final fluid depth E in. Absorption rate >= 600+
g.p.d.
Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date_
"NOTE: HOUSE WAS VACANT AT TIME OF TEST. DRAINFIELD WAS PRE-SOAKED WITH 1000 GALLONS OF WATER
IMMEDIATELY PRIOR TO TESTING. VERBAL APPROVAL FROM JEFF POET WAS GRANTED PRIOR TO TEST.
IN SHORT, 1600 GALLONS WAS INTRODUCED INTO THE DRAINFIELD AND IT REMAINED DRY.
D. LIFT STATION 'SEE ATTACHED MAINTENANCE INSPECTION REPORT.
10/12-111=006 Size in allons 66 Manhole/Access (YIN) YES
Date installed g
"Pump on" level at 24 in. "Pump otr level at 12 n. High water alarm level at 26.5 in.
Datum BOTTOM OF BASKET Cycles tested Meets alarm & circuit requirements? YES
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tanknift station on lot 1001+ On adjacent lots loo'+
Absorption field on lot 1001+ On adjacent lots 100'+
Public sewer main
Sewer /septic service line 251+
Public sewer manhole/cleanout N/A
Holding tank
Animal containment areas 501+ Manurelanimal excrete storage areas 1W+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 51+ Property line 51+ Absorption field 5'+
Water main N/A Water service line 10'+ Surface water 1001+
Wells on adjacent lots IW+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 101+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parkingtvehide storage 104
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that f have determined through field inspections and
review of Municipal mcords that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineers Printed Name JEFFREY A. GARNESS
Date I /t dly
(Rev.10/12112)
Frow ANCH TANK & WELDING INC 277 3715 09/03/2014 13:12
08/07/2012 04:16 9686770 AFL(JS
208 525
Now MEN ■ommum■ ■e now 8■ III as■o own ■ w— E
11.11 man 111 INS ■ ■ no ■ r ■ ■ MINE
n6■ ■■ ■o E SEE 8 no INS r11r m
a
Q Q
AdvanText Reid Maintenance Report
Annual Inspection
#316 P.1001/001
FADE 03
AnchorageTank
907-272-3543
Propady CwnerrnecMlnp #
PW (a•9)
OperMar
U
Aaron & Kristina Haynes
2nd Car nt
Mike Blakeslee
Previous
x1853 e<
PtevlCue
CeMeel Phcne
18531 Portugal Place, Anchorage AK 99516
907 349-0721
( )
Ay ah.Ion
Ceunry tCk
vada
FTU k&Lp
Deteml.eat h•poonw
AX -108932
SW060165
208409
RTU107968
12121/2012
Retrieve O&M Into
Recite mtlo—
Timer settings:
Perform Reid SamplingiMbsersations
NTU6.(,15xNT(Js)
PW (a•9)
cc (2-e)
U
Previous
2nd Car nt
Odor of sample
Typical �divaty [I Earthy ❑ Moldy
Non-typical);5±Wflda ❑Cabbbaarge� ❑Decay
oily Ir`.. h. MU ❑ yes 115NO
Foam In tank ❑ Yes `Utln
Check Control Panel
1
Racirc Aml olscharae A� � ((7 l L
c
Audible and visual alarms ;�3'OK
Dial tone (telemetry only) XYes ❑ No
Inapect/Claan Pump System
Inspect Clean
Rlsar/Lld .....................PrI
splice Box ....... . ........... y,,Cr'v.--L(((am.
ont C .........11....11
Monte ... .
:.;�7. r
Pump ........ . ......1111....
Blotube° Filter ...............
..�
Biotube Pump Vault ....1111- –11 .
Roeireulating 8PlIftur Valve....-.�
comments
Signature
Measure Sludge/Scum
9ludoa
Scum
1st Cgm 'Rnt
cunent
Previous
Current
Previous
2nd Car nt
Currant
Previous
currant
PtevlCue
Inspect/Clean AdvanTes Filter
Odor. 60MR1l
❑Pungent
Dlomet:
❑EUCORIVe
,,psr9p14�0rmel
BidglnWPending:'LrnanalMlnor
❑>=xcasaive
Inspect/Clann Discharge Pump System
Inspect
RlserAitl Fg
Splice Sox
Float cords
ins e%t Clean
(>,d Doti..
ottioriree
Pod Boom
intake Vent -M� It
Floats
pump
Inapect/Service other System Components
Inspect Clean
)lerntactlon Equipment ❑ ❑ Dispersal
pddlti al Services Il terry?
❑Clean tastily sheets? Replaced u
(� Ryptoce atl Dinar Items?
Parts Used. W = nry. B o :el'✓ appropriate syloction)
W 11 Ifem Nu Dy
Final/Safety Inspection
ASV reinstalled
. oId raconnocted; flush valvas Closed
Sum11�@r,mar lRecommendatlona
=.am ponorming; no further action needed
❑ Call for service
completed form to 1.866-384-7404
Inspect clean
Inspect Clean
s❑ ❑
...®.Lids bolted on
,AODMml panel reactivated
❑ lank need. pumping
[] Other?
I
Municipality of Anchorage
• '"� Development Services Department
Building Safety Division s h F r r
On -Site Water & Wastewater Program
4700 BragaW.Street._
P.O. Box 196650
Anchorage, AK 99519-6650 ).
www.muni.org/onsite
(907) 343-7904 r
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020-42-109 COSA#<
1. GENERAL INFORMATION Expiration Date: 3.-/7—
Complete
`-f7—Complete legal description PARADISE VALLEY; BLOCK 3 LOT 1
Location (site address) 18531 PORTUGAL PLACE *ANCHORAGE AK 99516
Current Property owner(s) TODD & DIANA BOYCE Day phone
Mailing address
Lending agency
Mailing address
18531 PORTUGAL PLACE *ANCHORAGE. AK 99516
Day phone
388-2705
Real Estate Agent LISA CONNER W/ PRUDENTIAL Day phone 244-2013
Mai[ing address 3801 CENTERPOINT DR. ##200 *ANCHORAGE, AK 99503
t:
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well
■
Individual On-site
0
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal a axed hereto and as of the validation date shown, baluow, i 'var�,y the"my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances; and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
in conducting this evaluation, GEG, LfD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily Identifiable features. The operational life, of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
DSD SIGNATURE
b�111_11 Approved for bedrooms.
Disapproved.
Phone 337-6179
Date I Z �-/a
Conditional approval for bedrooms, with the following stipulations:
Attachments:
COSA Checklist
Septic System Advisory
Arsenic Advisory
Maintenance Agreements
CE -7943
eaprofess*W' +oOFo
���OOOo�allt{tFF:r(�r
ON-SITE '; G
WATERAND
1biASTEWATER
PROGRAM
JJ6_,J 1 NSA=AFT CGN�1��11
JJJ1)1)))'i}}}�
Well Flow Advisory Supplemental Engineer's Report
ivii ate Advisory
Other
By:. Original Certificate Date:
(Rev. 11/05)
..t
Municipality of Anchorage
Development Services Department
a: 'x
Building Safety. Division "
On -Site Water & Wastewater Program s A E' Y
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
www.muni.org/onsite
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
Legal Description: PARADISE VALLEY; BLOCK 3, LOT 1 Parcel ID: 020-42-109
A. WELL DATA
Well type PRIVATE If A, B, or C provide PWSID# N A Well Log (Y/N) YES
Date completed 7/17/03 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES
Total depth 229 ft. Cased to 229 ft. Casing height (above ground) 24 in.
FROM WELL LOG AT INSPECTION
Date of test 7/17/03 11/29/2010
Static water level 151 ft. 145 ft.
Well production 20 g.p.m. 5.18 g.p.m.
WATER SAMPLE RESULTS:
Coliform 0 colonies/100 ml. Nitrate ND mg./L. Other bacteria 0 colonies/100 ml.
11/23/10 &
Arsenic: ND ug./L. Date of sample: 12/8/2010 Collected by: GEG Ltd.
B. SEPTIC/HOLDING THINK DATA JADVANTEX SYSTEM
Tank Type/Material STEP/STEEL Date installed 10/12-11/3/06
Tank size 1500 gal Number of Compartments 2 Cleanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (Y/N) YES
Date of pumping ** Pumper —
C. "ABSORPTION FIELD DATA *BELOW EXISTING GRADE
Date installed 10/12-11/3/06 Soil rating (g.p.d./ft2o 2/bdr 3.0 System type SHALLOWTRENCH
Length 40 ft. Width 5 ft. Gravel below pipe 0.6 ft.
Total depth *3+ ft. Eff. absorption area 200+ ft2 Monitoring tube YES Depression over field NO
Date of adequacy test*** 11 /29/2010 Results (Pass/Fail) PASS For 4 bedrooms
Fluid depth in absorption field before test DRY in. Water added 600 gal. New depth DRY in.
Elapsed Time: 0 min. Final fluid depth DRY in. Absorption rate >= 600+ g.p.d_
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date —
**PUMPING NOT REQUIRED PER MAINTANENCE REPORT. ***TRENCH PRESOAKED WITH 1000
GALLONS OF LIQUID. MOA APPROVED 1000 GALLON PRESOAK.
D. LIFT STATION *INSPECTED BY A+ HOME SERVICES. SEE ATTACHED INSPECTION REPORT.
Date installed10/12-11/3/06 Size in gallons 1500 Manhole/Access (Y/N)
YES
"Pump on" level at TIMER in. "Pump off' level atTIMER in. High water alarm level at 25.5 in.
Datum BOTTOM OF TANK Cycles tested * Meets alarm & circuit requirements? YES
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot 100'+ On adjacent lots 100'+
Absorption field on lot 100'+ On adjacent lots 100'+
Public sewer main N/A
Sewer /septic service line 25'+
Public sewer manhole/cleanout N/A
Holding tank N/A
Animal containment areas 50'+ Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main N/A Water service line 10'+ Surface water
100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION OF q
I certify that / have determined through field inspections and �,�
review of Municipal records that the above systems are in ' ' ' ' ' ' ' ' .. ' ' ' ' ' ' ' ' ' ' '
conformance with MOA COSA guidelines in effect on this
date. Q Je A. Ga ess. •
Engineer's Printed Name JEFFREY A. GARNESS Q�� E-7953 0�4'1
J.7,
Date d2 �y� /o ,@ '
40��F'ro f es siol'o
COSA Fee $ ( q Waiver Fee $
Date of PaymentaT If d Date of Payment
Receipt NumberReceipt Number
(Rev. 11/05)
'Vj / Tract B
% cj I Green Belt Reserve
L=94.91' % \
R=375.00' / 2 a,
A=14 30 5" �.4.Tt)
y
1
O. `�
House 'c
/
Lot 2
i
ICn
0—" �� N
�o
Lot 1 1to
3
to
0
O
a7
t
Lot 3.�� OF Ai`'4
NOTE:: 1) Bearings and distances are Record as per Plat No. 76-79.
2) The 2 septic vents/cleanouts near the house were surveyed in 2009,
but were mistakenly not shown until this copy (12/15/10).
5ENTEC
O Septic vent
Surveying • Engineering Sl 12VEY C'1`1011�1CAT[ ON: SN'1'1-.0 has conducted O Septic tank
2525 Gambell Street, Suite 200, Anchorage, Alaska 99503 a physical survey of this property as shown on this
Tele: (907) 563-3835 Fax: (907) 563-3817 draw inr and that the improvements situated thereon are 0 Found property cor.
within the property lines and no encroachments exist
AS BUILT OF: LEGAL DESCRIPTION outer than noted. S Well
Lot 1, Block 3, Paradise Valley Subdivision, EXCLUSION NOTES: It is the owners responsibility
Anchorage, Alaska to determine the existence of any easements, covenants,
M t' hi h d
law
AMW �. . .. I
*: 49' T-1
jj Jorerny A '�Hurst
I�.
No. LS•11796 y ./
`��rOF�SS101L`�~y
LEGEND
or res c tons w c o not appear on the recorded
WORK ORDER NUMBERDATE., t vU111ZED
Note) •,
AUG.9 "=5aa «iu+eaiteant,com subdivision plat. NOTE: Under no circumstances
09-5324 ]RA WN BY BY "r •"c should any data hereon be used for the construction or
JAH JH N :\ 1 593,45-4, for the establishing of property lines.