Loading...
HomeMy WebLinkAboutTRAILS END BLK 3 LT 10 Municipality of Anchorage pa~e Development Services Department On. Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND]OR WELL INSPECTION REPORT Permit Number: SW020307 PID Number: 015-191-41 Name: Larry_& Rebecca McBain WastewaterSystem: New 3936 Tom White Circle Anch., AK 99501 ABSORPTION FIELD 338-7701 Four (4) , Shallow Bed LEGAL DESCRIPTION ,', ' 4 3 10 Trails End1 1.5 ~,. 30 Well: New c,,~e.~0':,: . .um~oe,,.~: j 15 ! Private 267,~. 73 ,,. 450 ,e ASTM 3034 PVC Hefty Drilling 8/26/2002 30 ~,. Alaska General 9/17-18/2002 SEPARATION DISTANCES El Septic I-'1 Holding I-I S.T.E.P. D Other.  Septic Absorption Lift Holding :'ublic/Pdvate Manuraclurer. ~3~Da~[¥i~Gafions. Tank Field Station Tank S~,erUoe Anchorage Tank 1,250 wo, >100' >100' N/A N/A >25' Steel Three (3) s~.=ow.,., >100' >100' N/A N/A ~ ~**LIFT STATION~,..~,.~,.,. - NONE ONi LOT t~u., >5' 4' N/A N/A 250 o.,.IAnchorage Tank/Orenco Foundation ~'5' ~'10' N/A N/A ~0-~'" ~,. ~'0. C,r~.,U,,., None Noted Orenco Municipality of Anchorage .See Lot Line Waiver. Gravity. Flow From BENCH MARK Manhole to CO 2. Garage Slab. lO0.O F,. Engineer's Stamp - %- ,t '-.:.~% Inspections performed by: A. Harala Dates: 1st 9/17/02,,, .' 49th ' ,~.o....[ ................ ; ..... 2"d 9/18/02 . Department of Health and Human Services approval '*~-&'~.. ~o. c~-,~, Reviewed and approved by: /~/ZC,/. ,,~Date: /--/['2 8 - 03 ¥,~fi; ........ ~" 9;' / · ' / Municipality of Anchorage Page 2 of'3 / DEVEOPMENTSERVICES DEPARTMENT 47~0 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number:. SW020307 / PID No. 015-191-41 I I [ , ~ A B C ~ C3 59,2 34.8 ~. C4 33.0 32.5 ~ M~ 33.5 25.2 ~. Mt 27.2 26.6 Four Bodroom Homo Alt. Site C4 MU OTH BROWDER AVENUE Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343~7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW020307 96.4 _/ 100.6 4 x~/'~P~ ,T"T-~ ' II / Page 3 of 3 PID No. 015-191-41 99.0 Geolextile Fabric 2' Insulation Drainfield Rock '~--95.85 30' ~96. / 87.0 PROFILE AS-BUILT Scale: 1' = 10' ANDERSON ENGINEERING P.O. BOX 240773 ~ ANCHORAGE, AK 99524 522-7773 522-6779 (FAX) August.18, 2002 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Lot 10, Block 3, Trails End Subdivision Separation Distance Waiver Absorption Bed to Lot Line Dear On Site Services Engineer: We hereby apply for a lot line waiver to allow the absorption bed on Lot 10, Block 3, Trails End Subdivision to be constructed as close to the eastern property line as possible. The east line borders on a 60' Municipal right of way and will not impact the currently vacant lot on the east side of the right of way. Field investigations found this area to have the best underlying soil for the construction of a new absorption bed. We are also planning to install an Advantex Treatment System on the lot which normally treats septic effluent to much higher standards than a standard septic system. No conflicts were noted between this absorption bed and septic systems on adjacent lots. We therefore recommend the lot line waiver be issued allowing the bed to be constructed within 1' of east lot line. Sincerely, Michael E. Anderson, P.E. Permit Number ~'u.)g)Z~3,~ 4)~7 Date Of Issue_~_.-Z./-~ 2. Parcel Identification Number 6)/J"-/g/- .~,// Date Started - Date Completed ..~_.-~ ~ Z. Is well located at approved permit location? yYes L3 No Legal Description Block Lot Property Owner Name & Address; Borehole Data: Depth '~ethod Of Drilling: ~ air rotary [~ cable tool Soil Type & Thickness & Water Strata From To Casing Type:~Wall Thickness. z~..,,~qnches DJameter_.~;L._lnch es, depth_~_~feet Liner Type: Diameter inches, depth , feet ; Static Water Level (from ground level): ~ feet. E./ u ~ PumpingLevek feetafler, hm.~mping gpm' ' Recove~ Rate: Welt Intake op~ning TyPe: D O~n End ~O~n Hole D Screened; Sta~ feet Stopped feet 'O Pedoratlons Sta~ feet Stopped feet ' ~ GroutType: ~m[[~ Volu~e e ~O~ A/ ~/ Depth; from ~ feet, to ~ , ,,fe~t' Pump Intake Depth:, feet ~/~/~! ~ ~ PumpSize ~p BrandName Well Disinfected UponCompletlen? ~ Yes ~ No ~ t~/~ ~ Method Of Disinfection: ' / - ~ Comments: Attention: The well driller shall p[ovide a well log to the property owner within 30 days of completion and the property owner or the well driller shall provide a well log to the Dept. of Health & Human Services within 60 ,days of completion. Building Permits LARRY MC:~A I N ~0'?' BUILDINO PERMIT REPORT 6102 Po01 Page 1 of 2 Permit number:. 02 8983 Date of application:' 2002-09-30 00:00:00.~) Permit Ciasa; RESIDENTIAL PROPERTY Property tax c, ods number: Subdlvlelon: LoV,,pace: Block: Tract: Plat: Grid: Zoning district: Site Address: Se~&,a~ diel~l: Water supply: 01619141000O1 TRAILS END 10 3 000000 6W2641 R-9.~RURAL-RES IDENTIAL 11200 BROWOER AVE, ANC'HORAOE PROJECT Project Name: Proposed u~e: Type of work: Work description: Value of construction: General contr-,clor(a): Items submltta¢l: SINGLE FAMILY RETROFIT Septic lift station $o ED'S ELECTRIC, INC. None Cl~nge Ordem: Change ,Order Valuation Date Description 0 $0 2002.09-30 septic lift station o8:o2:41,0 Items re.submitted: None 8too Work Ordem: Posted D. ate ..... Re~eon J 2002-08-21 OBTAIN ROW PERMIT FOR NEW DRIV'EV~AY BEFORE O,0." JS 00:00:00.0 ....... ISSUI~D. . .. , 120o3-o44e ~:X):00:O0.0 PI. AN REVIEW~ Plane reviewed: None PERMITS Permlt~ laeued: j~ permit 'rye. . I Issuance ~yl:)e [ELECTRICAL IRETROFIT I Date J ' I.euecl To ..... J J 2002'09'30 IED'S ELECTRIC, INC. I http://pas.ci.aachorage.ak, us/pasfouildingpcrmits.cfm?pcrmitid=139920 Received Time Apr.23. 3:21P~,{ 4/23/2003 APR--~--208~ 84:19 P~ LARRY Building Permits MC~AIH 90? 6182 P.02 Pag¢2 of 2. INSPECTIONS Rnal,lrmpe~lons: , , I , Discipline ~IURGOYNE, CURT L. 2002-10-14 00:00:00.0 COMPLETION C~ditional Certlfl~te of Oc~pency (GCO) date: None Certifi~te of Occupancy' (CO) date: 2OO2-12-30 00:00:00.0 http://pas.ci.anchorage.ak.us/pas/buildingpermits.cfrn?permitid-13 9920 Received Time Apr.23. 3:21PM 4/23/2003 MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O, Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Permit Number: SW020307 Legal Description: TRAILS END BLK 3 LT 10 Design Engineer: 0014 Anderson Engineering Owner Name: Larry & Rebecca McBain Owner Address: 3936 Tom White Circle Anchorage, AK 99501- Date Issued: Aug 21, 2002 Expiration Date: Aug 2¥ 2003 Parcel ID: 015-191-41 Site Address: Lot Size: 22785 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field r~ SepticTank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection, Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15. a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B, Covered, sealed, and heated to prevent freezing. Received By~ Issued By: Date: Date: ,.~~~--. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (9O7) 343-79O4 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-191-41 Permit Number SWOZO~3O7 Properly owner(s) Lam/and Rebecca McBain Mailing address (1) 3936 Tom White Circle Anchoraqe, AK 99501 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 10, Block 3, Trails End Subdivision Legal description (Section. Township & Range) Lot Size 22,785 SF Acres/Sq. Ft. Number of Bedrooms Four {4) Day phone 338-7701 THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [] [] Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that lhis application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. {Signature of property owner or authorized a§eat) Permit Fees: Date of Payment: Receipt Number: (Rev. 12./00) Waiver Fees: Date of Payment: Receipt Number: ENGINEERINGi!:i!: iJ. ".,':'ANCHORAGE;': AK 99524. ', ~': :;' ?' :'.522-7773~.i :L ': :?.i? } 522,;,6779'(FAX):- August 18, 2002 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 10, Block 3, Trails End Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 10, Block 3, Trails End Subdivision intends to construct a four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to serve the proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new and alternate septic system and the parameters used in the design. Also identified on the plans are the proposed well location, sub drain location, test hole locations and the locations of the existing wells and systems on adjacent lots. Drainage arrows are also shown and current drainage patterns will be maintained after construction. The lot was originally found to be plagued by high ground water. Further investigation and excavation revealed lenses of frozen ground, which appeared to be holding the water in place. A sub drain was constructed along the northern property line, which is now controlling groundwater elevations. Recent water monitoring revealed levels at 5.6' to 9' below the surface. We are proposing to use an Advantex Treatment System with AX20 Filter in Mode lA. This system has been proven effective in areas with high groundwater. The test holes placed near the location of the proposed and alternate absorption beds indicated silty sand with gravel and varying amounts of silt and a percolation rate of between 11 and 15 minutes per inch in the accepting layer. We are therefore proposing to construct a 15' wide by 30' long absorption bed. The size of the bed is nearly 3 times larger than that recommended for the Advantex system. The distribution piping will be placed at 1' below the existing ground surface. Total depth of the bed will be 1.5', which is more than 4' above the highest noted groundwater level on the lot. The test hole in the area of the bed has indicated groundwater at 6' below the surface. The absorption bed will be constructed a minimum of 20' from the sub drain. The ground surface on the lot slopes as shown on the attached Site Plan with fairly Lot 10, Block 3, Trails End August 18, 2002 Page Two shallow to no slope in the area of the new absorption trench. The new septic tank and absorption trenches will be constructed in a fairly shallow surface slope area behind the proposed house in conformance with Municipal requirements and parallel to ground contours where possible. All components of the new trench will be constructed a minimum of 100' from the well proposed for the lot. The system will also be constructed a minimum of 100' from any surface water in the area and 10' from the water service line. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments ~89 ~55'50'£ 18824 7 2 3 4 18~.44 VAC~T 8 THIS PI: OJECT 16 17000 VACANT ~ 4 ~,.?.;.. -.'.....?£% · , ~...- ~_ '.,.~' + . AREA SYSTEM PLAN '.~'~'.~--...--'-":.-*~ BROWDER AVE. I 30.0 O 30.0 J 3 .,00,00.00 S 30 ' Long Bed TH4 Advante ~" ~.~-..~.' Treatmel 24.0 System [th24'0 ~ AX20 .~.A e Four '. 10X94 ~m ~ ~.Bedroom.~ ~ ~ = ~ Hom~ ~ ~ = 48.0 D 0 ,5' UTILITY EASEMENT .~'6'6 t t ~-O_j'-' HI,ON / SITE PLAN SCALE 1" = 30' LOT 10, BLOCK 3, TRAILS END SUBDIVISION ABSORPTION BED DESIGN FACTORS: SYSTEM REQUIREMENTS: 4 Bedroom Home Perc. Rate: 10-15 Min./Inch Application Rate: 4 GPD/SF Shallow Bed Disposal System 4 Bdrm. Advantex Treatment System -1' Total Drain Field Rock 4 Bedrooms X 150SF/Bedroom /4 GPDISF (Application Factor) = 150 Square Feet 150 SFI15 LF (Width of Bed) = 10 LF Length of Bed Therefore: Construct an Abso~'ption Bed Larger Than Design Requirements 30' in Length and t5' Wide for a Total of 450 Square Feet of Absorption Area. Bottom of Distribution Piping to be Placed 1' Below Original Ground Level. Place Clean, Coarse Sand to Level Existing Ground. Bottom of Bed to be 1.5' Below Original Ground. Mound Over Bed to Provide 3' Minimum Cover or Provide 2' Direct Bury Insulation and 2' Minimum Cover to Prevent Frost Penetration. 4" DIAMETER PVC ' MONITOR TUBE (SCHEDULE 40) '~ ,~ ,~ ! · · I NOTE: SHALLOW BED DETAIL (NO SCALE) Grade Area to Drain Away. Maintain 6' Separation From Bedrock. Provide 3' of Cover or 2" Insulation and 2' Cover. Maintain 4' Separation From Groundwater. Maintain 100' Separation From Private Well and Surface Water. AdvanTex' Treatment System--'-?-:~. ~ '" .o~..~ -~ I P.E, ~ 'I'H? AX20 - Mode la °,'"" ~ ~ 40x94Pod --- NOTE.: THE BOARD .Ih'~L,'I.AT]ON TO BE: INS-'TAM.~D ~ THE SF.J'IIC TANK & ,~ BEYOND ON ALL SIDI~ E3(CE3~T UNDER THE: /d:~t~J. crEx FILTT. R. ~llS WILl. ~LLOW FOR HEAl' TO [SC. AP[ FROll TANK & RISE TO ME: FILTI~ ABOVE IT. INLET OF $° PiPE ov~ 1'HIS CONNEC'~ON TO PRO/il)Ir [X't~:tO TO BT~D(~ I~CAVA'I1ON BIO'R.,~D~ SCRI~NED VAULT DTLUENT PUWP SYSTEM SECTION ~./~/ - NOTE; SYSTE~ ~UST BE P~CED IN STRICT CONFORMANCE WITH ~NUFACTURER'S RECOMMENDATIONS. -~... .... ,., ~** · · Municipality of Anchorage Development Services Depadment/On-Site Water and Wastewater Program 4700 South Bragaw Street, Anchorage, AK 99516-6650 SOILS LOG - PERCOLATION TEST Performed For. Larry_ McBain Legal Description: Lot.10..Block 3. Trails End Subdivision SLOPE Date Performed: SITE PLAN 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 18 19 MI/SM Silt with Sand TESTHOLE NO. 1 SMIML Sand with Silt See Site Plan Bottom of Hole Was Groundwater Encountered? Yes If Yes, What Depth? 6' Depth to Water After Monitoring 6' Date: 8115/02 sI East to West ~ 5% to lO% Reading Date Gross Net Depth To Net Time Time Water .Drop I 2-Aug 12:36 5.25' 2 13:06 30 8' 2.75' 3 13:07 5.25" 4 13:37 30 8' 2,75' 5 13:38 5.375' 6 14:08 30 8" 2.625" Parc. Rate: 12 MinJlnch Perc. Hole Diameter.' 6" Test Run Between 2.5 Ft. and 3.5 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Alan Harala. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With Ail State and Municipal Guidelines In Effect On This Date: 8115/02 Municipality of Anchorage Development Services Department/On-Site Water and Wastewater Program 4700 South Bragaw Sb"eet, Anchorage, AK 99516-6650 SOILS LOG - PERCOLATION TEST Performcd For:. Lam/McBain Legal Description: Lot 10. Block 3. Trails End Subdivision GM Silty Gravel TJ~STHOLE NO. ~ Silt Clusters SMIML 7.6' Groundwater SLOPE Was Groundwater 9 Encountered? Yes S If Yes, What Depth? 7.6' L · 10 Bottom of Depth toWater O Hole After Monitoring 7.6' P 11 Date: 8115102 E Date Performed: 8/1/02 SITE PLAN See Site Plan East to We~t @ 5% to 10% 12 13 14 15 16 17 18 19 Reading Date Gross Net Depth To Net Time Time 'Water Drop I 2-Aug 12:40 2.25' 2 13:20 30 5.13' 2.88" 3 13:21 2.25" 4 13:51 30 5' 2.75' 5 13:52 2.25" 6 14:22 30 2.13" 2.62' Perc. Rate: 11.5 Min./Inch Parc. Hole Diameter:. 6" Test Run Between 2.5 Ft. and 3.5 Ft. Comments: Percolation Cavity Presoaked Prior to Testing. Performed By: Alan Harola, I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 8115102 Municipality of Anchorage Development Sen/ices DepartmentJOn-Site Water and Wastewater Program 4700 South Bragaw Street, Anchorage, AK 99516-6650 SOILS LOG - PERCOLATION TEST Performed For:. Lam/_ McBain Legal Description: Lot 10. Block 3. Trails End Subdivision SLOPE Date Performed: SITE PLAN 811/02 10 11 12 13 14 15 16 17 18 19 GM Silty Gravel TESTHOLE NO. 4 ..~'7_ 5.6' Groundwater MUSM See Site Plan Bottom of Hole Was Groundwater Encountered? Yes If Yes, What Depth?. 5.6' Depth Io Water After Monitoring 5.6'. Date: 8115/02 East to West @ 5% to 10% Reading Date Gross Net Depth To Net rime Time Water Drop I 2-Aug 12:45 1.5" 2 13:15 30 3.75' 2.25' 3 13:16 1.5" 4 13:46 30 3.63" 2.13' 5 13:47 1.5" 6 14:17 30 3.63" 2.13' Peru. Rate: 14.1 MinJInch Peru. Hole Diameter:. 6" Test Run Between 1.5 Ft. and 2.5 Ft. Comments: Percolation Cavity Presoaked Pdor to Testing. Performed By: Alan Harala. I, Michael E. Anderson Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Date: 8/15/02 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 10, BLOCK 3, TRAILS END SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new Advantex Treatment System with an AX-20-Mode la 40x94 Pod at the location shown on the Site Plan. The new septic system also includes the construction of a new 30' long X 15' wide absorption bed at the location also shown on the Site Plan and at the configuration shown. The distribution line in the bed will be placed at 1' below the existing ground surface. The total depth of the bed will be 1.5' below existing ground. The new system must be placed a minimum of 100' from the proposed well on the lot and those on adjacent lots and 10' from the water service line between the well and the house. It must also be placed a minimum of 100' from any surface water. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions Or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION The Advantex Treatment System must be installed in conformance with specifications and regulations furnished by the manufacturer, Anchorage Tank and Orenco Systems Incorporated. No variances from the manufacturer's specifications will be allowed without pe[r[~ission from the manufacturer and Municipal representatives. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Lot 10, Block 3, Trails End August 18, 2002 Page 2 of 2 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct budal insulation. o A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: The drainfield shall be constructed to the dimensions shown on the design. The bottom of the bed shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to prOvide a minimum of 2" of cover. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The podion below grOund must be perforated. Contractor shall vedfy the septic tank and drainfield are a minimum 100' away from any pdvate water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rOck. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally apprOved septic tank manufacturer. 2. The following pipe materials are apprOved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct budal polystyrene (Dow Chemical Co. Styrofoam HI or equal). Lot 10, Block 3, Trails End August 18, 2002 Page 3 of 3 4. Septic tank inlets and outlets shall be fitted with watedight couplings (Caulder, Femco, or equal). 5. A pe,,;eable geotextile fabdc (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Parcel I.D. 15-191-41 ' 1. GENEi~LINFOI~MATIO.. Con~Plete legal description '." Development Services Department. On-Site Water and Wastewater Program 4700 South Bragaw St. ,,~.d P.O. Box..196650 Anchorage, AK 99519-6650 .~1~_ '" '_ CERTIFICATE OF HEALTH Au~HORITY APPROVAL. · ' FOR A SINGLE FAMILY DWELLING ' Expiration Dale: '7- Lot 10, Block 3~ Trails End Subdivision . t!oiipi! .addr , or d rec,ons) Current Property owner(s) Larry and Rebecca Mc. Bain Day phone 338.T/01 Mailing a~:e~s ~- 3936 Tom White Circle Anchoraqe, Al< 99501 Lending agency , Day phone 'Refil Estate Agent ' ' ........... : ........... Day phone Mailing Address" ' . i. Unl~ss otherwise requested, HAA w~7I be held by I~SD forpickup. 2.' NUMBER OF BEDROOMS: 3. 'TYPE'OF'WATER SUPPLY.v'' Individual Well Individual Water Storage Community Class ~. Well Public Water System Four (4) ' TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] ~E] Individual Holding tank ~E] Community On-site [] Public Sewer [] I The Municipality of Anchorage Development Services Department (DSD) Issues Cedificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from lhe date of issue for propodies served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties sen/ed by Class A or B wells or a public water system. The Municipalily of A.n,chorage ts. not responsible for errors or omissions in the professional engineer's work. " 4; STAT'FMENT OF-INSPECTION BY ENGINEER As cedified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water suppJy and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms an~d type:of, st~uclure md~cated hereto. I further verify that based on the mformabon obtained from the Mun~c~pahty of,Anchorage files and from my mvesbgabon and mspecbon, the on-s~te water,supply and/or wastewater d sposa system is(are) in compliance with a Iapp ~cab e Municipal and Slate codes,..or~nances, ,,a. nd' reg'ula{ions in effecl at the time of installation. -~?,..~; - . : . Name of Firm Anderson Enqineerin.q · Address P.O. Box 240773 Anchoraqe, AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE Approved for y bedrooms. Disapproved. . Phone 522-7773 Date 4/2812003 - :,,. ,,. ~,~,;. -'"-.._',.~: e. ,,' (o :..- ~t -"-...-:~, **. ,I.'' '" ,4 h.. Conditional approval for bedrooms, with the following stipulations: Additional Comments ~ '.. WASTEWATER .- ~. _.. PROGRAM A '~ -Attachments: HAA Checklist Septic System Advisory Well Flow Advisory X Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: --//- ~ ~ ',~ - ~ 3 (Re,,. t' _: .: Development Services Department Legal Deseription: A. WEL.L DATA Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 wv~v.ci.anchorage.ak.us ( 07) 343-7g04 HEALTH AUTHORITY APPROVAL CHECKLIST Lot 10, Block 3, Trails End Subdivision Parcel ID: 015-t91-41 Bo If A, B, or C provide PWSID # __ Sanitary seal (Y/N) Y_ Cased to ~'3 fi.. .... Well type Private Date completed 8/26/2002 Total, depth-. 26/...ft.~ .... Date of test Static water level ' Well production WATER SAMPLE RESULTS: Coliform 0 colonies/10Oml. FROM WELL LOG 8r26/2002 30 ft. 6 g.p.m. Well Log (Y/N) Y Wires property protected (Y/N) Y · .. Casing height (above Ground) 24. AT INSPECTION lin. g.p.m. Date of sample: 4/24/2003 SEPTIC/HOLDING TANK DATA Nitrate ~,6 mg./I. Collected by: A. Harala Other bacteria 5 colonies/lO0 mi. Tank size le500 gal. Foundation cleanout (Y/N) Y_ Date of pumping ABSORPTION FIELD DATA Tank TypeJMatedal Septlc/Steel/Advantex Number of Compartments _3 Depression over tank (Y/N) N_ Pumper Date installed fl/18/2002 Length. 30 Total depth 3_ ft, Date of adequacy test Date installed 9/17/2002 Claanouts (Y/N) Y High water alarm (Y/N) Y Soil rating (g.p.d./ft~ or ft=/bdrm) ,4 GPD/SF System type Shallow Bed ff. Width 15 ff. Gravel below pipe .5 Eft. absorption area 450 ft~ Monitoring tube Y_ Depression over field N Results (Pass/Fail) Fluid depth in absorption field before test ~ in. Water added gal. Elapsed Time: __. min. Final fluid depth in. Absorption rate >= Any rejuvenation treatment (past 12 mo:) (Y/N &type) N .... If yes, give date For · bedrooms New depth in. g.p.d. Do LIFT STATION Date installed 9117/2002 'Pump on" level at Datum Bottom of Tank E. SEPARATION DISTANCES Fo Size in gallons 250 'Pump off' level at~l),~n. Cycles tested Manhole/Access (Y/N) Y High water alarm level at 52 Meets alarm & circuit requirements? Y in. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100' Absorption field on lot >100' Public sewer main N/A Sewer/septic service line >25' On' adjacent lots >100' On adjacent lots >100' Public sewer manhole/cleanout NIA Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Water main NIA Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line 5' Water Service line >10' Curtain drain >20' COMMENTS Property line >5' Water service line >t0' Building foundation >t0' Surface water >100' Wells on adjacent lots >t00' Absorption field >5' Surface water >100' Water main >10' Driveway, parking/vehicle storage G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 4/28/2003 HAA Fee $ .,~1~ ~ ~- ,'~1 ~ Date of Payment_ 54/Z,~/O ~ Receipt Number -~/~7/ -%'"~~,~' (Rev. 12/00) Waiver Fee $ Date of Payment Receipt Number c~ ~ 0 NORTH 11 9.93' .LN31~13S¥3 ~Lln~ln .~ I I Z