HomeMy WebLinkAboutSKYHILLS PH 2 BLK 3 LT 16Permit Number: ,~g~/I~"Z~oI.'~.N'
LEGAL DESCRIPTION
Municipality of Anchorage ~.
Development Services Department :
Building Safety Division
On-Bite Water and WaBtewater Program. 4700 S. Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650 Page of
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
PID Number: ~3 ti-- l tg...rO..- ~ ~--
Wastewater System: J~New [] Upgrade
Well: [] New [] Upgrade
SEPARATION DISTANCES
Holding
Tank
PubhclPrivate
Sewer Line
\ /
ABSORPTION FIELD
~l~Oee¢~ TmccJ'~ t"l Bha1~ Trenc~ {~] Bed r'l Mou~
TANK
[~Septic I-] Holding t'=l S.T.E.P,
$"t F.-~- t...
Other
BENCH MARK
Caoac,:y
LIFT STATION
GalJ Mar~lacl~er /
Engineer's
i Insmections performed by: '~)~. ~ Dates: 1" ~"'A~
....
Developments Depa.mentApproval / /
Rev,ewed and Date: ~/~1/'Z I ~% ~?~ .~ '.
approved by: ~ ~
~. AF 54.5
'~r'_ 52.5
!
A~ 2f %".
1500 GAL. SL'ITIC TANK
57 tT LON~
IIITDL. Eio
~ IT SI3~ ROCK.
5 IT COVL'R
'
· 25 0 ,2"3 .~ 75 IflO
$CALE~ I' = 50 FT.
L//
UNflEVELDPEfl
135 150
B~ I44RK
PON'L~ PL'flL~TAL
~SUYL'fl LT. EVA1710N I00.00 IT
TOBBEN SPURKLAND P.E.
205 W 15TH. AVENUE
AI~Ctt. AK. 9950!
II
LOT 16 BK 3 SKYHII, L
~tlCHELSOtlN AND DAUGHTER
HEAVENLY CIRCLE
II SEPTIC SYSTEId AS BUILT
DATE: JULY 12, 2002
SHEET: 2/3 GRID: 2222
PE£HIT # $VO3fll£4 PID # 0]1-]££-4£ SKHfl3I~£.DVG
Standard Trench:
2' Vide
57' Long
1I' Deep
6,0' Sewer rock
5' Cover
0 ~ I258 gal Septic tank
NO SCALE
, Monitor
~ Cleanouts
5' Cover
6,0 ~ o~ Septic ~ock --/
Effective
SCALE
1500 gal. soptlc tank
AS BUILT
TDBBEN SPURKLAND P.E. II
203 ~%5th Ave
II
Anchorage Ak 99501
~7~-3~16
LO1' 18, BLOCK 3, $I¢Z7tlii//2
iilCHELSOHN AND DAUGXTE£
SEPT[C SYSTEH SCHEHATZC
~ATE, JULY 12, 2002
SHEET, $/$ ORID, 2222
PE£/dlT ~ SW050124 PARCEL /D / 011-122-,12 SKHO$1~$.DWG
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: May 09, 2003
Expiration Date: May 08, 2004
Permit Number: SW030124
Legal Description:"SKYHILLS BLOCK3 LOT 16
Design Engineer: 0007 Tobben Spurkland, PE
Owner Name: MICHELS~HN & DAUGHTER CONSTRI
Owner Address: 8325 HEAVENLY CIRCLE
EAGLE RIVER, AK 99567-
Parcel ID: 011-122-42
Site Address: 8325 HEAVENLY CIRCLE
Lot Size: 42580 SQ. FT.
Total Bedrooms:~A"..~,.. Permit Bedrooms:
This permit is for the construction of:
[] Disposal Field [] SepticTank [] Holding Tank [] Privy
[] Private Well ~ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B, Covered, sealed, and heated to prevent freezing.
Municipality of Anchorage
Development ServiceS' Department
Building Safety Diviston
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650'
www.cl.anchorage;ak.us
(907) 343-7904
ON-SITE SEWEPJVVELL PERMIT APPLIcATIoN
FOR A SINGLE FAMILY DWELLING
ParcelI.D. 0/]--/22 -'CZ
Permit Number.SW~3
Property owner(s)
Mailing address (1) 7~ ~ ~i ~
~ address (2) ~
Legal description (Lot, Block & Sub'd.) ~O~
Legal description (Section, Township & Range)
Lot Size ~ Z/~80 Acre~ ·
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Day phone ~z-
Number of Bedrooms ..~ _~
~ Well Only. []
Water Storage []
Jacuzzi
Water Softening Unit ~]
I certify that the above information is COrrect. I further cedify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner. ~r at~odzed agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
..~ /'l/f-)~ ~ Waiver Fees:
~/?~ ~ Date of Payment:
~,? (~ e) ~. Receipt Number:
'F.S]PU] L_ 24'D P.E.
203 W lSth. Avenue, Suite 203
ANCtIORAGE, ALASKA 9950 I
(907) 279-3916
Fax (907) 276-4013
SEPTIC SYSTEM DESIGN
LOT 16 BLOCK 3 SKYHILL #2 S/D
MICHELSOHN AND DAUGHTER
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 Bragaw Street
Anchorage, Alaska 99519-6650
May 5, 2003
We are submitting an application for the installation of a septic system for this lot. The submittal
consists of three (3) drawings showing the present improvements on the lot and the adjoining
properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is
subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil
logs and percolation tests of applicable testholes are also enclosed. The septic system design is
based on the following:
No Ground Water or Impervious Layer to 17tL
Use Standard Trench
Soil Rating. From Testhole 4-21-03
3 rain/in ~ 1.2 gal per sq.ft/day
No. of Bedrooms ~ ~
Required Area per Bedroom: 150/!.2 -- 125 sq.lL
Total area required: 125 x~--5~0 sqft /a~
Testhole depth 17 feet
Bottom Rock At 11 feet
Top Rock At 5 feet
Rock Depth 6 feet ~.,~
Minimum Trench Length '5~'/12 =4~'~. ~'~.
SYSTEM CONFIGURATION
STANDARD TRENCH/,, 0
TOTAL LENGTH ~ FT
TOTAL WIDTH 2 FT
TOTAL DEPTH 1 ! FT
ROCK DEPTH 6 FT
COVER 5 FT
SEPTIC ANK ~ GAL
The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent
lots.
There are no developed or natural surface / sub surface drainage comes on this or the adjacent lots.
The proposed septic system will not change the general slope ofthe area. Ponding and/or concentration of surface
nmoffwill not result from this installation.
UN~EVELDPE~
TOBBEN SPURKI.,4ND P.E. l[
205 I¢ 15TIL AVENUE
II
ANCH. AK. 99501
LOT 16 BK 3 SKYHIL£
MICNELSONN AND DAUGNTER
HEAVENLY CIRCLE
J J SEPTIC SYSTEM DESIGN
DATE: tl,4Y 5, 2005
SHEET: 1/$ GRID: 2222
PERMIT # SWO3OXXX PID # xxx SKHO316].DI~G
/
I
TOBBEN DPURKLAND P.E.
205 W ~STtl. AVENUE
ANCtl. AK. gg501
PERMIT #S~/O$OXXX
50 7~
SCALE, I' = 50 FT.
UN E VEL DPEfl
,I
II
LOT 16 BK 3 SKYHII. L //2
t, IICtlELSOtlN AND DAUGHTER
HEAVENLY CIRCL~
SEPTIC SYSTEt, i DESIGN
DATE: t~AY $, 2005
SHEET: 2/3 GRID: 2222
Piti # xxx SKHOS16~fl~6
Standard Trench;
2' Wide
58' Long
11' Deep
6.0' Sewer rock
5' Cover
NO SCALE
1250 gal Septic tank
SI! t: Borrler---~'
6.0 £~ o£ Septic Rock
Effective
Monitor
/-- Cleanouts ~
5' Cover
NO SCALE
1250 ga£ septic tank
TnBBEN SPURKLAND P.E. Il
203 ~/15~h Ave
II
AnchorG9e Ak 99501
~79-3916
LOt ~, $~,ocg 3, sKn~i~
MICHELSOHN AND DAUGHTER
HEAVENLY CIRC/.E
I I SFPTIC SYSTEM SCHEMATIC
~AT£, ~,,4Y .~, ~OOJ
SHE:E:T, S/J GRI~, 2222
PERWIT ~ SWOJOOXX PARCEL /D ~ XX SKHOJIE3.DP/G
Municipality of Anchorage
Development Services Department
Building Sa[et'/Division
On-Site Water and Wastewater Program
4700 South Bragaw SL
P.O. Box 196650 A~chorage. AK 99519-6650
www ¢i.ancheraqea~<.us
(907) 34 3.7 .e'04
Soils Log - Percolation Test
Legal Descdpt~cm ~ T I b. ~ ~ Ownsh~p Ran~e,~ec~cn:
~ Stc~e Site P~n
1-
2-
3-
7-
£-
c~.
10-
11
13-
14-
15-
15.
17-
;=.,.
~.
20.
t'iL
G; t-t--
CO,'.t:,!E,"IT S
WAS GROUND WATER
E;:CCU::T--R--D?
IF YES. AT WHAT DEPTH?
Oeplh to Water Alter
Monitoring?
I
I
L~v'I,=',.L ! I I I
Re-"ding
t.L
1,1.4
II
PERFORMED I,H ACCORDANCE-V~TH ALL STATE AND MU,";ICIPAL GUIDELINES I,',1 EFFECT OH Tills DATE. DATE: ,.~... ~ ~.~.~