HomeMy WebLinkAboutSKYHILLS PH 3 BLK 3 LT 28 MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Aug 05, 2003
Expiration Date: Aug 04, 2004
Permit Number: SW030297
Legal Description: Skyhills Phase Ill Block 3 Lot 28
Design Engineer: 0014 Anderson Engineering
Owner Name: Archid Designs, Builders
Owner Address: P.O. Box 212576
Anchorage, AK 99521-
Parcel ID: 011-122-60
Site Address: Unknown
Lot Size: 44797 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank ~ Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AACS0 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing,
Received By: ~,L¢_ ~,t~
Issued B y,'~.._~(~.,~ ~
Parcel I.D.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www. ci.anchorage.ak, us
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Permit Number SW
Property owner(s) AP, CHID Designs: Builders
Mailing address (1) F,O, Box 212.576 Anchorage. Alc, 99.521
Mailing address (2). Zip Code
Legal description (Lot, Block & Sub'd.) Lot 28, Block 3, Skyhills Phase III
Legal description (Section, Township & Range)
Lot Size 44.797 RI: Acres/Sq. Ft. Number of Bedrooms .Four (4)
Day phone 338-7278
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
[] Well Only []
[] Water Storage []
[] Jacuzzi []
[] Water Softening Unit []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: ~t:~p ~ Waiver Fees:
Date of Payment: '~/,PO/p 3' Date of Payment:
Receipt Number: ,,~ O~ -~ / 0 Receipt Number:
(Rev. t 2/00) ~ '~
July 29, 2003
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Lot 28, Block 3, Sky Hills Subdivision Phase III
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 28, Block 3, Sky Hills Subdivision Phase III intends to construct a
four-bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new septic system to serve the new home. The subdivision is served
by the Municipal Water System. The attached Site Plan and backup documentation
identify the location and configuration of the new septic system and alternate site and
the parameters used in the design. Also identified on the plans are the location of the
water service on the lot, test holes and the septic systems on the surrounding lots.
Drainage arrows are shown indicating the current drainage patterns. The drainage
patterns will be maintained after construction.
The test holes placed near the location of the proposed absorption trench indicated fine
sand with some silt to a depth approximating 20' and percolation rates from 1 to 5
minutes per inch. No groundwater was found during placement of the test holes, and
none was noted during the monitoring period. We are therefore proposing to place a
new 1,250-gallon septic tank and a 50' long x 5' wide x 4' effective depth absorption
trench. The distribution pipe will be placed 3' below the existing surface and the total
depth will be 7'. Sufficient fil~ will be placed over the septic tank and absorption trench
to Prevent freezing.
The ground surface on the lot slopes at shallow grades from northwest to southeast
with a steep drop off at the back of the lot. The absorption trench will be constructed
parallel with the slope as much as possible in conformance with Municipal
Lot 28, Block 3, Sky Hills Phase II!
July 29, 2003
Page Two
requirements and more than 50' from the bluff line. All components of the new septic
system will be constructed a minimum of 10' from the water service on this lot and 100'
from any surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
]. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
21'
45,6,35 ~q'ft
SLOPE
MAIN]ENANOE
EASEMENT
23
41.161 sq.ft
O~AINAG~" EASEMENT
10'
m' ~'~
DRAINAGE ~AINTENANCE
EASEMENT' '
EASEMENT
. ,,.~_,~ ~ 24 · '- ·
~_~_^ 41,347 sq ft
I {
.~ 27
~) 41,892 sqtft.
~7-~-^
?
~. ~ ~C~ EASEMENT (S~ NOTE ~0)
N89'SS'28~E 768.34'(
45,103 sq.ft
10' DRAINAGE AND ~A.}L '
EASF3JENT
10' SLOPE & TP
TRAIL EASEM E.N T~
20' TRAIL 5:2-3-9
~As~ENT 32
~0,418 sq.ft .'~
31.
4o,¢50 sq.ft
· LOT.~O
THIS PROJECT
TRACT A' ',
107,780' Sq':~t. ~
MICHAEL E. ANDERSON
No. CE-498!
MOUNTAIN/ -/
CIRCLE~
~.\ ¥..........~ \ ,~ , ,o~o.oo.. ,~9.~8,
LOT 2 ' -
~ ~ 1~ U~LITY EASEMENT
S 89~5'28" W 52~.77'
SITE PLAN -¢~:; .............. ~'~"
LOT 28, BLOCK 3, SKY HILLS SUBDIVISION PHASE ,,,
LOT 28, BLOCK 3, SKY HILLS SUBDIVISION PHASE III
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom House 5' Wide Trench System
Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank
Application Rate: 1.2 GPD/SF 4' Drainfield Rock
4 Bedrooms X 150 GPD/1.2 GPD/SF (Application Rate) = 500 SF Absorption Area
500SF/5 LF 0Nidth)* .5 (Red. Factor) = 50 LF Trench Length
THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench.
Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be
7' Below Existing Ground. Maintain 10' Separation From Water Service Line. Place 2' of Direct
Bury Insulation and 2' of Fill Over Absorption Trench or Provide Minimum 3' of Cover to
Prevent Freezing. Place 4' of Cover Over Septic Tank.
2a6'~
Natural
Backfill
Geotextile
-- Fabric
4" Perforated
PVC (Holes Down)
-- Drainfield Rock
TYPICAL 5' WIDE TRENCH SECTION
-- ---- ~C~L~-"~--'--- --~ ~;~
NOTE: Grade Area Over Trench to Drain Away, ~.'.'~? 49th
Minimum 6: Separation From Bedrock. ~,.~__...~.
Minimum 4 Separation From Groundwater.
~.----~
Minimum 10' Separation From Water Service Line,
Minimum 100' Separation From Surface Water or Streams.~ ~'~¢~/'~'* ~'~ '"', No. CE-4381
Mun!cipality ¢f Anchorage
Department of Health & Human Services
825 L Street. Anchorage, AK 99502<)650
SOILS LOG - PEROOLATION TEST
Performed For: B.~b Klein :
Legal Description: Lot 28. Block 3, Sky Hills: Phase III
SLOPE
5
6
7
8
9
10
1.1
oG/PT
TESTHOLENO. 28-3-A ·
Was Ground~vater
Fine Sand Encountered? No
If Yet,' What Degth?
Some Silt Depth to Water
After Monitoring None
Date: 10tl.0/99
Date Performed: 9/28/99
/1
=========================
S
0
P
E
5% '-'1 0%
1'2
13
.14
15
16
18
2O
CE-4381
Clean Sand
SP
Bottom of
Hole
Reading Date Gross " Net Depth To Net
Time Time ' Water Drop
5 15:03 .25"
Perc. Rate: 2 Min./in0h Perc. Hoie.,Diameter: 6"
Test Run. Between 6 Ft. and 7 Ft.
,Comments:. Percolation Cavity Presoaked Prior 'to Testing.
Performed By:. ~LS..sJZdC, Ls..cz~. I, i I , . Certify That This Test Was Performed
In Accordance Wit;% All State and Municipal Guidelines In Effect 'On This Date: 1'0125/99
MuniCipality of Anchorage
Department of Health & Human Services
825 L Street, Anchorage, AK 99502-0650
SOILS LO(~? PERCOLATION TEST
Performed For: Bob Klein
Legal Description: Lot 28. Block 3. sky Hfl.ls.. Phase
'4
' 6¸
7
8
9
10
12
~3
14
15
18
Date Performed: 9/28/99
OGIPT
TESTHOLE NO. 28-3-B-
SP
SP
' SLOPE SITE PLAN
Fine Sand
No S
5~ - 1 0%
L --
None' P
10/10~99 E
Read!ng Date' Grdss Net Depth To Net
I Time Time Water Dr~p
1 28-Sap 15:22 .5"
2 15:32 10 2.5" ' 2"
3 · '' 15:33 .5~'
'4 15:43 10 2.5" 2"
5 1.5:44 ,25".
6" ~ 15:54 10 i. 2.25" 2"
Was Groundwater
Encountered?
If Yet, What Depth?:
Depth to Water
After Monitoring
E, AN<DER$Ohl ~"
Per~. Rate: 5 Min./lncl~ Perc. Hole D ameter: 6"
Bottom of Te~t Run Between 6 Ft. and 7 Ft.
Hole
Comments: Percolation Cavity Presoaked Prior .to Testing.
Performed By: Ed Sanderson. .1, Michael E. Anderson certify That This ?est Was Performed
In Accordance With All State and Municipal Guide ines tn Effect On This Date: 10/25/99
. Municipality of Anch(~r~ge'
Department of Health & Humar~ Services'
825 L Street AnchQrage, AK 99502-0650
S'OILS LOG - PERCOLATION TEST
.Performed For: Bob Klein
Legal Description; Lot 28. Blbck 3. Sky Hills. Phase Ill
9
10
11
12
13
14
15
17
18
Date Performed: 9/28/99
Apparent
Fill Area
GM
TESTHOLE NO. 28-3-C-
Was Groundwater
Encountered?
If Yet, What Depth?
'Depth to Water
. At,er Monitoring
Date:
SP
Fine Sand ~% '
~ ' TH ' .~'
Hole -.
SLOPE' ~' . ~ : SITE PLAN
S
.L -- 5% _ .1
None P
10/10/99 E
~,eading Date Gross. Net Depth To Net
Time Time Water DroP)
1 28-Sep 16:08 '.5"
2 16:18 10 6.5" 6"
3 13:I9 .5"
4 16:29'.' 10 . 6.5" .6"
5' 16:30 .25"
6 16:40 10 6.25" 6"
Perc. Rate: 1.7 Min./inch Perc. Hole Diameter: 6"
Test Run Between 7 Ft. and 8'Ft:
Comments: Percolation Cavity Presoaked Prior to Testing.
Performed By: Ed Sanderson. i, ' h I n ' Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 10125/99
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 28, BLOCK 3, SKY HILLS SUBDIVISION PHASE III
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250-gallon septic tank at the location shown on the site plan.
Work also includes the construction of a new absorption trench 50'
long by 5' wide by 4' effective depth also at the location shown on the
Site Plan. The total depth of the trench will be 7' below existing
ground and the distribution pipe will be placed at 3' below the surface.
All components of the new absorption trench and septic tank must be
constructed a minimum of 100' from any surface water and 10' from
the water service on this and adjacent lots. A minimum of 4' of cover
is required over the septic tank and 3' overthe absorption trench. In
lieu of cover 2" of direct bury insulation and 2' of cover may be placed.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground
utility locates and for the layout of the septic system and verification of
the location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must
receive prior approval from D.H.H.S. before beginning system
installation.
SEPTIC TANK INSTALLATION
1. A new 1,250-gallon septic tank must be procured from a certified
septic tank manufacturer if the existing tank is found to be defective.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
Lot 28, Block 3~ Sky Hills Phase III
July 29, 2003
Page 2 of 3
o
The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2"of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion belOw ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock4 All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
Lot 28, Block 3, Sky Hills Phase III
July 29, 2003
Page 3 of 3
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be tiffed with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.