Loading...
HomeMy WebLinkAboutDENALY BLK 1 LT 14 •p 1 Lot 14 #067e041 e20 Berm must be in place for approval of future COSAs . On-Site Wastewater Disposal System Permit _ow n a - Hard MUNICIPALITY OF ANCHORAGE C Development Services Department o, ; On-Site Water& Wastewater Program girl ' I Department 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161327 Tax Code Number: 06704120000 Work Type: Septic Upgrade Permit Effective Dates: to November 03, 2017 Design Engineer: ARC TERRA CONSULTING INC Subdivision: DENALY Site Legal Address: DENALY BLK 1 LT 14 G:0363 Owner/Address: GLAUSER CHAD R & KRISTEN M 7001 KULCHAY CIR EAGLE RIVER AK 995779100 Site Mailing Address: 7001 KULCHAY CIR, Eagle River Lot Size in Sq Ft: 60692 Total Bedrooms: 5 This permit is for the construction of: Y Disposal Field N Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: 1. Engineer needs to do an additional percolation test prior to construction of septic fields. Stamped and signed results to be submitted with inspection report. If the results require a design change, construction of the system will stop pending On-Site review and approval. 2. Protective berm must be in place at time of inspection report. Received Bye 111e • Date: /// Issued By: aGC('1( ( aNter Date: (f/23/f6 nr Sn Municipality of Anchorage \',` M: oiet �: P.O. Box 196650 0 4700 Elmore Road Anchorage, Alaska 99519-6650 0(907) 343-7904 0 Fax (907) 343-7997 http://www.muni.orq/Onsite' Development Services Division On-Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV161143 COSA#:_ Permit#: OSP161327 • PID#: 067-041-20 Legal Description: Denalv Block 1 Lot 14 Engineer: ArcTerra • Applicant: Chad & Kristen Glauser Your request for a waiver of the required 100 feet horizontal separation from the existing and proposed absorption fields to surface water has been approved. The approved separation distance is 50.0 feet. See engineer's letter for waiver request. , ' This waiver approval applies to the existing and proposed absorption fields only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. - Waiver is Granted: X Waiver is not Granted: ' Date: 11 /28/)o1 Approved by: teefte.te,4 dvc.o-(.p/Q Name of Reviewer **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Ct I Phone: 907-343-7904 Development Services Division / Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 067-041-20 Property owner(s) CHAD & KRISTEN GLAUSER Day phone 726-1014 Mailing address 7001 KULCHAY CIRCLE, EAGLE RIVER, AK 99577 Site address 7001 KULCHAY CIRCLE, EAGLE RIVER, AK 99577 Legal description (Sub'd., Block & Lot) DENALY BLOCK 1, LOT 14 Legal description (Township, Range & Section) Lot Size 60692 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (0 all that apply) Absorption Field Exr Initial ❑ Single Family (SF) [ (w/wo ADU) Septic Tank ❑ Upgrade XDuplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Obsoreiron ceIan -o sw.Ijac.a wcktr Distance: 50' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. i' / (Suture of property owner or authorized agent) sh Permit/Rush Fees: 54€1 "' Waiver Fees: 6 5c1 / Date of Payment: /f f /i(o Date of Payment: A11 23/a 01 co Receipt Number: 1 tat I 0 b Receipt Number: O R n 8 5b Permit No. OSPI le I3 Waiver No. CSN 1 (01143 Permit App_9-1-12.doc ROTE ARC TERRA �4\ CONSULTING. INC 212 E. 51 Ave, Anchorage, AK. 99503 Office(907) 868-3791, Fax(907)868-3793 November 1, 2016 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Upgrade Sewer Permit— Denaly Block 1, Lot 14 It has been determined that the absorption field of the subject property is saturated. Subsequently, the owner has requested we proceed forward to obtain a septic permit to upgrade the septic system. The general slope of this lot is from north to south at a grade of approximately 8- 13% over the septic area. We will be utilizing the existing MOA records performed to investigate soils and groundwater for the original and reserve fields. The proposed upgrade will serve the existing 5-bedroom single-family residence. An existing drainage ditch runs along the western portion of the lot and on the adjacent property. Per MOA recorded observations of this property and our investigation, no surface water was present or running and it appears to be a typical drainage ditch handling storm / seasonal events. The ditch was heavily vegetated with tall grass. The property and adjacent lots are served by private water. No surface water was observed within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868-3791 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Ir /11 Kenneth M , Attachments: On-Site Sewer Application Wastewater Absorption System Details/Site Plan Soils Log / Percolation Tests—MOA Record Copies 20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793 • tl,.. cTERR4 ♦ 8 ARC TERRA $ 0 r _ , CONSULTING, INC 212 B. 51" Ave, Anchorage, AK. 99503 Office(907) 868-3791, Fax(907)868-3793 November 19, 2016 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject Upgrade Sewer Permit— Denaly Block 1, Lot 14 Per your review comments, please see the attached modified design for your review and approval. An additional testhole will be performed prior to construction. As far as the review comment regarding the existing drainage ditch that runs along the western portion of the lot and on the adjacent property -- it appears to be a typical drainage ditch handling storm / seasonal events. No water was present per MOA recorded observations of this property on 8/27/01, 4/20/02 & 9/19/02 by Greg Allen Eberle, PE. Also no water was present based on our own observations on 5/2/11, 10/27/16 and 11/18/16. Furthermore, after speaking with John Semon of Northern Excavation who installed the adjacent lot's septic system — no water was present on 3/27/14 or at anytime he was on the site. The ditch was heavily vegetated with tall grasses and as stated previously handles storm /seasonal runoff events. The property and adjacent lots are served by private water. No surface water was observed within 100' of the proposed system and there are no known curtain drains within 50'. We do not expect there to be any adverse effect on adjacent lots by the development of this system. If you have any questions, please contact me at 868-3791 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. Kenneth M. Duffus, .E. Attachments: Wastewater Absorption System Details/Site Plan 20441 PTARMIGAN BLVD • EAGLE RIVER,AK 99577-8736 • PH(907)868-3791 • FAX(907)868-3793 tis* RRq ,' F ARC TERRA ER12A • CONSULTING, INC •eg<° >a, 212 E. 51st Ave, Anchorage, AK. 99503 .�. Office(907)868-3791, Fax (907)868-3793 November 23, 2016 Municipality of Anchorage Development Services Department On-Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Surface Water Waiver— Denaly Block 1, Lot 14 Per previous discussions regarding the drainage ditch along the western portion of the subject property, we respectfully request a waiver to surface water of 50' from the existing and proposed septic fields. To mitigate the unlikely event of effluent-surface water interaction of these MOA perceived encroachments, a berm will be installed to direct potential effluent overflow away from the ditch as shown on the attached design. We do not expect there to be any adverse effect on the subject or adjacent lots by granting this waiver. If you have any questions, please contact me at 868-3791 / FAX 868-3793. Respectfully submitted, ArcTerra Consulting, Inc. aW Kenneth M. Du ' s, / Attachments: On-Site Wastewater Design WELL & WASTEWATER DISP❑SAL SYSTEM DETAILS/SITE PLAN DENALY BLOCK 1, LOT 14 BCI-1 LOT 12 LOT 1A • Sp'05 AYW N BLK 1 wObiJ. N89 44.53-W 20.00' `b ." LOT 14 'y, BLK ' , 'crnAae J ;,�R„, gin ; � r OR ,,,,,y Niba 4 i . nJ1' j LOT 15 F H BLK 1 . 4Ittiestes4lilf - .• 4w � � z iwwa a �► r 0 m STAKE ALL REQ. SETBA . S x E- PRIOR TO CONSTRUCTION "°"""" A e s E- PC (I.E. - LOT LINE, ESMT, WE - .... e x 1 414 N .4'Ipw A NO SLOPES >20% DESIGN DETAILS W/IN 100' OF PROPOSED 5 BDRM X 150 GPD = 750 GPD SYSTEM. 750 GPD/0.8 GPD PER SQ. FT. = 938 SQ. FT (938 SF/ 5' WIDE (0.5' GRAVEL) = 188 FT. TRENCH NO PUBLICWELLS WITHIN 200' OF PROPOSED SYSTEM. USE 4 TRENCHES - 47 (L) X 5' (W) X 0,5'(ED) NO PRIVATE WELLS WITHIN 200' OF Total depth of system Is 2' from original grade. PROPOSED SYSTEM EXCEPT AS NOTED. NO SEPTIC SYSTEMS WITHIN 200' OF Total•• depth of gravel below distribution pipe is 0.5' . PROPOSED WELL EXCEPT AS NOTED. NOTES: 1. CONTRACTOR TO CONNECT TO EXISTING SEPTIC TANK BY INSTALLING DIVERTER TO ORIGINAL& UPGRADE FIELDS. Scale: 1'= 100' 2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM. PAGE 1 OF 3 3. ADDITIONAL FILL WILL BE ADDED OVER SYSTEM TO ACHIEVE MIN. 2' COVER WITH INSULATION. 4.. CONTRACTOR WILL ENSURE ALL SEPARATIONS TO ADJACENT —Si:1110111L\ WELLS & SEPTICS, EASEMENTS, & OTHER SETBACK REQUIREMENTS. Aar (Sy OF 1195 PREPARED FOR: �'� � `�� 1 CHAD & KRISTEN GLAUSER ft *. n •."� + 7001 KULCHAY CIR. 104:`-iit.;„R� 9 TH ' * / EAGLE RIVER, AK 99577 `O.�� FS : FIELD BOOKS couPUTm: a 0 C, 16 W� / eouNDARY:BOUNDARY_ DRA"N: BMW i •1 4 �4 ' ��� / ti srAxlNc: STAKING aE«m:KMD w�/ Z'S//� / As811lLr: JLS DATE 11/1/16 �° \ �� 1 \ FESSION= DWC. FILE: MID: SW0363 'O4 ,'6Y o \`_ ACAD FILE: ' No.: 16-240 H,ssuLTING .fie,•• FILE AK,sgsTT� /Volumes/ArcTerra Shared/Storage/WELL & SEPTIC — Filed By Legal/Densly Subd/BIk 1 Lot 14/Trench Design2 With Berm.dwg WASTEWATER DISP❑SAL SYSTEM DETAILS DENALY BLOCK 1, LOT 14 0 1 2:-U-1—l-14.0' 1174 a o 11.5' o Cn a_ o 4 �i a • EXISTING o 17 17 M 1'' 5-BR NOUS , _ 44.0' I'� . 16.0' • D • COVERED 6pFCC • 2 CK SCREENED DE DECK sJPPORTS o�o PORCH • -----1500-GAL S.T. INSTALL DIV. Z 6F�`� _ GRAVEL w TH "PP-2" , WALKWAY > w s INSTALL _J fc2 z o CO /TH "PP 1"I -•() SPLITTERS w �° ai Q Q w it o 37 0,• _-eco co I- CO IM1T / w �T !CO IImmo ��,,.\ CO M�1 . CO TO CONST. 1 p �O -10' -1 'ROTE•TIVE •..8Iat:dpj Xo xERM TO RECT -...00lI, LU cY a a- 100'+ FROM 11 TCH r�'RFACE FLOW EAST & I o cos I 0 0 w z I F- Scale: 1'= 30' alo-"IS.A`71.41\ PAGE 2 OF 3 i /�T�� �I �<Qs 1 PREPARED FOR: / �� TH j� 9 1 CHAD & KRISTEN GLAUSER RClERR * :40 • * Y 7001 KULCHAY CIR. oy �. y`t .IEAGLE RIVER, AK 99577/}� _' D S I FIELD BOOKS COMPUTED: A e M ` CE �: W� et BaJNDARY:BOUNDARY DBA"w' BMW > ` ' 1 InsslO t$ 4, STAKING STAKING cHECRED: KMD - ' r �/LGA I ASBUILT: JLS DATE 11/1 X16 1'. -. ��AK g/'R \\ e DWG. FILE: GRID' SW0363 TQC' cb N N4C "i `` ACM ALE: .CB No.: 4/16-240 `S ALT I NG 'esti FILE 16-240 AN.99571' /Volumes/ArcTerra Shared/Storage/WELL & SEPTIC - Filed By Legal/Denaly Subd/BIk 1 Lot 14/Trench Design2 With Berm.dwg WASTEWATER DISP❑SAL SYSTEM DETAILS DENALY BLOCK 1, LOT 14 4' MONITORING TUBE 4' CLEANOUT MT O CO 4' DISTRIBUTION LINE 0 Co a 5' 54' FROM TANK PLAN VIEW LEACHFIELD DETAILS —4' CLEANOUT 4' MONITORING TUBE— _INSULATION / 6' TOPSOIL & VEGETATION 0 0 FILTER FABRIC NO FINAL GRADE PEN 'P 3`. 5 021°- 2' MIN COVER 04°- ii f 2.0' DEEP ORIGINAL GRADE •.•.. •.••.••••••••.•.•..• -•' —REMOVE ALL ORGANICS 00000* 60000••444407.07440:44444 •g 4.. 0.5' SEWER ROCK INSITU MATERIAL PROFILE VIEW PAGE 3 OF 3 LEACHFIELD DETAILS NOTE' BOTTOM OF SEWER DRAINROCK MUST BE 4+ FEET -410,1C":111/4 ABOVE HIGH GROUNDWATER. OF, \ ALL MOA MOUND REQUIREMENTS APPLY Scale: NTS Alir �� A45 1 PREPARED FOR: G`S "� 1, CHAD & KRISTEN GLAUSER hRCTER * 9TH . * 7001 KULCHAY NIR. c1 iliNsh,17_ EAGLE RIVER, AK 99577 1 SFlELD BOOKS courui[u: 2 oi et•$ CE- �8 ,C BouNDARv:BOUNDARY DRAWN: BMW : 3' .1 r1 t//, ,/i4 N'' STAJaNGSTAKING CHECKED: KMD .�� 1r • Ott, ,, + /il R PI'�'" / Assuar. JLS DACE: 11/1/16 ` �-y;,�•. \ FESSIONe ti DWG. FILE Kala: SW0363 'cif \ri 14,(A\ \`\I qiy `'SULTI NG. bL ACAD FILE: ALE JCB No.: 16-240 eR' AK.se571'"3 /Volumes/ArcTerra Shared/Storage/WELL & SEPTIC — Filed By Legal/Denaly Subd/Blk 1 Lot 14/Trench Design.dwg Municipality of Anchorage:.,t~.," Development Services Department ..~ Bu~ing Sai'ety Division On-Site Water and Wastew~ter P~'ogram. 4700 S. Bragaw St. n~ L~' P.O. Box 196650 ,anchorage. AK 99519-6650 Page of www.cLanchorage.ak, us (907) 343-7S04 ON-SITE WASTEWATER DISPOSAL SYSTEM .AND/OR WELL INSPECTION REPORT Permit Numbe~. -~ ~ O I O B c~ ~ P~D Numbe~. ' Q ~'"~-- Oq I -- ~-O LEGAL DESCRIPTION · · Oe$~l SEPARATION DISTANCES  Septic Abso~on l~ Ho~ing Pub~ ~""~': BENCH MARK Developmen~ Se~ices Depa~ment Approval ' ~.~~ E~ .:~ UNDEVELOPED 12 UNDE~LOPED 15' 6os 16 UN[ LocQtlon 4gth BRIAN C,. MAN~:~LD <~(:~.%<~, LS-B62~ LOT 14, BLOCK-l, DENALY SURDIV]$10N MANGOLD HOME PLOT PLAN 5CN..E.: House (D f./') 0 T 0 0 0 -~ O0 0 0 Job No.: 02-I 16 M-W bt'illin.ct. ]:nc. +P.O. Box 110378+Anchorxge. AK 99511+ +907-345..4000 · 907-345-3287 Fax+ THIS IS A CERTIFIE,D COPY .... Project No.: N/A Permit No. SW010393 Groundwater Well As..Built & Log Well Owner: Mangold, Brian G. & Carleen A. *LegalDescrlptlon: Denaly Subdivision Block I~ Lot 14 , Eagle River, Alaska Use of Well: Domestic Construction · llole Depth: 86' · Casing Size: 6" · Cased To: 84.73' · Material: A 53 Steel · DrillMethod: Air Rotary .............................. Perf. * Well Completion- Open end X Screen · Screen/Perforatlon description: None · Grout Notes: (4) Sacks- No. 8 bentonite granul, · Notes: · WellDevelopment: Method: Ab' stage Nottx: · Static water level (SWL) 3' (above) (belm~ top of casing (TOC). · Wellyleldtestat 10-15 gallonsperminute(GPM)/gallonsperhour(GPll)for I hours with 100% of drawdown (DD) from stat lc level (SWL). · Method: Air lift · Date ofcompletion: 09 May 2002 · Pump Install: Well Log, Deptl~ i~ feet from "' top of casing. Details of formations penetra ted~ size of material, color and hardness. 0 TO 2 Casing stickup 2 TO 7 Fill andtopsoil 7 TO 17 Gmvel:cobbley 17 TO 23 Clayey gravel: brown ... 23 TO 48 Gravelly clay 48 TO 50 Boulder 50 TO 80 Gravelly clay 80 TO 86 Water bearing gravel: 10-15 gpm, slightly saD. dy TO TO TO TO .,.y')~/,.,.-~"- ~ ~_,:.L"'~_._~ To TO TO Certiflea~ No'$. 814 & MUNICIPALITY OF ANCHORAGE Building Safety Division MEMORANDUM DATE: August 28, 2003 TO: FILE FROM: Joe Goodall Engineer II, On-Site Water Wastewater Program SUB J: DENALY $/D BLOCK 1 LOT 14 I have been instructed by Jim Cross to approve this as-built inspection report. Greg Alan Eberele, P.E. stated on the as-built inspection report there is no surface water within 100 feet from the septic tank or absorbtion field. On the proposal site plan there was no water drainage indicated. However on the as-built site plan Greg Eberle, P.E. then showed a drainage ditch. But stated on the inspection report, surface water "None". WELL AND SEPTIC SYSTEM AS-BUILT PERMIT NUMBER: SW010393 PARCEL ID: 067-041-20 LEGAL DESCRIPTION: DENALY SUBDIVISION, BLOCK 1, LOT 14 TI4N, RIW, SECTION 23 LOT SIZE: 60692 SQUARE FEET or 1.39 ACRES OWNER: BRIAN G. and CARLEEN A. MANGOLD OWNER ADDRESS: PO BOX 773214 EAGLE RIVER, ALASKA 99577-3214 DESIGN ENGINEER: GREG EBERLE, PE CE 9254, ALASKA DESIGN FIRM: LOUNSBURY & ASSOCIATES, INC. MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Sep 25, 2001 Expiration Date: Sep 25, 2002 Permit Number: SW010393 'Legal Description: DENALY BLK 1 LT 14 : Design Engineer: 0821 Eberle Engineering Services Owner Name: Brian G. & Carleen A. Mangold Owner Address: PO Box 773214 Eagle River, AK 99577- Parcel ID: 067-041-20 Site Address: Lot Size: 60692 SQ. FT, Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of: [] Disposal Field ~ SepticTank r-'] Holding Tank r--] Privy r~ Private Well [~ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. ~5.' The following special provisions. PRIOR TO CONSTRUCTING THE WATER WELL, THE WELL DRILLER SHALL SUBMIT A DRILLING PLAN TO THIS OFFICE. THIS PLAN SHALL SHOW HOW THE WELL CONSTRUCTION WILL PREVENT ALL LEAKING '.. THROUGH THE CASING ANNULUS FROM THE CONFINED AQUIFER. Received By: ~ Issued By:~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWEPJWELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLI'NG Parcel I.D. , 0(.¢)~ ' ~ I-;:)"/~ ' .' _ . , Permit Number ~,.1~,~0[~ phone t~O~"~'"{.'~.~ Propertyowner(s) ~V-~,'t. ~ '~ ~~.~,x ~3~ , · Day Mailing address (1) -~) ~O"{, "~3 3~'-~'1"~ Mailing address (2) Legal description (Lot, Block & Sub'&) L ;~'/'~ Legal description (Section, Township & Range) Lot Size :,~?;q. Ft.. Zip Code Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [] .~. Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct, I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signa'~uure of property owner Waiver Fees: Date of Payment: Receipt Number: Lounsbury and Associates, Inc 723 W. 6th Avenue Anchorage, Alaska 99501 (907) 272-5451 Lot 14, Block t, Denali Subdivision--Pmt. Application The attached site plans shows: a) Locations of the proposed on-site wastewater (WW) disposal system with all its components as well as adequate area for a replacement WW disPosal site. b) Measured dimensions of the proposed on-site WW disposal field, tank, and distribution piping. c) Measured distances to all VVVV disposal systems, wells, surface water or drainage courses, roads, property lines, and structures within 200 feet of the location of the proposed and existing WW disposal systems on this lot. d) Location of the percolation test/test pit where the water table monitoring tube was placed. e) Topography is 10% sloping nearly due south. The proposed well and septic system will have very limited impact on adjacent properties for the following reasons: a) The surrounding lots have sufficient room for septic sites, b) Future neighboring septic systems will all be 30' distance minirnatly; all surrounding properties are as yet undeveloped. c) Reserve space is adequate, due to absorption capacity. d) Drainage will not be affected and is not a major consideration in our design. No impacts of{he WVV disposal system on adjoining properties are anticipated. All requisite separation distances relative to adjoining wells, VVW disposal systems, and this lot's backup site are met herein. There are no known curtain drains. LEGAL: SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM Lot 14, Block 1, Denali Subdivision August 25, 2001 A. GENERAL 1. The septic plan is for a single-family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. Ail materials and workmanship shall meet the Anchorage Department of Health and Alaska Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. Ail excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage and Alaska Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi-family wells. 7. The excavation is to be exactly in the area shown on the site plan; any deviation requires engineer approval. 8. It is always recommended that a surveyor locate the nearest lot line position and the location of any easements. 9. Any remaining open test hole excavations shall be filled. B. BED 1. The bed is to follow the natural land contour to maintain uniform total depth of the bed bottom. 2. The bottom of the bed shall be level, plus or minus 1.5". 3. The total depth of the bed excavation is not to exceed 4' at any point. 4. The effluent line within the bed shall be laid level within 0.03'. 5. The bed gravel Is to be covered with typar fabric material. 6. Soil or combination of soil and extruded board insulation to a depth of 3' minimum or equivalent is to be placed over the leachfield. 7. The area over the bed is to be finish graded to prevent ponding of surface water runoff. 8. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. .i~COMMENDED LEACHFIELD DIMENSIONS: ~T~~I,,,-'~nlT~ G.,RAVEL DEPTH = 0.5' under pipe, 2" over pipe BED LENGTH = 63 BED WIDTH = 15 SOIL RATING = 0.8 GPD/sq. ft BEDROOM CAPACITY = 5 SEPTIC TANK SIZE = 1500 gals. ~, Twenty-four (24) hours notice required forall inspections. · tOT 14. BLOCK 1, DE)iAU SUBOIVISION LOUNSSURY AND ASSO~AITS PLAN VI------~ 16 13 14 1 15 ,osed Well New 100 SCALE 20Oft I Gas x 63' Tm~k La~ch F~ld M.r,k:~aty M Ar.::horage. DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L' Street. Anchorage..,,~ska 99502-0650 SOILS LOG -- PERCOLATI0 (~BEGORY ALAN EBEBLE PERFORMED FOR:~ 1 2 8- 7- 8- 9. 10- 11- 12- 13- 14- 15- 18- 17- 18- 19- 20. COMMENTS WA3 GROUND WATER ENCOUNTERED? c~' t IF YE~ ~T ~n'fAT ~,. ~l~!o, ~._. ,, PERFORMED 2 8- 7- 8- 9- 10- 11- 13- 14- 10- 17- 18- 19- 20- DEPARTMENT OF HEALTH & HUMAN SERVICE~ SOILS LOG-- PERCO~ON ~ ~' ~'( /I q~.. ~ ..~ SLOPE SITE PLAN /,"TII · tl !11 I1-1 Ill .'Ill II 'i Il. I If I 'WAS GROUND WATER Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DVVELLING Parcel I.D. 067-041-20 1. GENERAL INFORMATION Complete legal description Expiration Date: DENALY BLOCK 1, LOT 14 Location (site address) 7001 KULCHAY CIRCLE, EAGLE RIVER, AK 99577 Current Property owner(s) BRIAN & CARLEEN MANGOLD Day phone Mailing address PO BOX 773214 EAGLE RIVER, AK 99577 Leriding agency Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless othe~vise requested, COSA will be held by DSD for pickup. 2. NUM. BEROr~ BEDROOMS: 3..,~TYPE OF WATER,SUPPLY: -IndiVidUal. Well Individual Wa: .tcr Storage Cohimunity'-Cla~s Well Public Water System 5 TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [~ [] Individual Holding Tank [-'1 [] Community On-site E~ [] Public Sewer E~ The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ARCTERRA CONSULTING, INC. Phone 868-3792 Address 20441 PTARMIGAN BLVD., EAGLE RIVER, AK 99577 Engineer's Printed Name KENNETH M. DUFFUS Date. 5/12/2011 Engineer's Comments: This investigation was comploted in compliance with ADEC and MOA regulations. The assessment of the condition of the well and septic applies only to the conditions as of the day tested. The flow and absorption rates may change due to subsurface conditions that may not be observed from the surface, changes inland use, local soil characteristics, groundwater levels that may fluctuate during the year and the water usage of the family being served by the system. The operational life of all well and septic systems are subject to these various and dynamic characteristics and are outside the control of the evaluator of the well and septic system. Therefore, ArcTerra can not give any estimate of how long a system will function satisfactory for current or future occupants or can ArcTerra guarantee that no unseen encroachments, deficiencies or discrepancies exist. DSD SIGNATURE '~.~ Approved for ~ Disapproved. bedrooms. Conditional approval for bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: v - Municipality of Anchorage Development Services. De, partment Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: DENAL¥ BLOCK 1, LOT 14 Parcel ID: 067-041-20 A. WELL DATA Well type PRIVA~ IfA, B, or C provide PWS!D # Well ~ (Y/N) __Y Date completed 5-9-2002 Sanitary seal (Y/N) Y__ Total depth 86 lt. Cased to 85 lt. FROM WELL LOG Date of test 5-9-2002 Static water level +3 lt. Well production 10-15 g.p.m. WATER SAMPLE RESULTS: Coliform NEC colonies/100mL Nitrate 0.42.5 mg/L Arsenic: ND mg/I Date of sample: 5-2-2ffll Collected by:. A~cTerza B. SEPTIC/HOLDING TANK= DATA Tank Type~laterial SepticJC:en~rete Date installed 4/20/2002 Tank size 1500 gal. Number of Compmtments _2 Cleanouts (Y/N) _Y Foundation cleanout (Y/N) _Y Depression over tank (YIN) ___N High water alarm (Y/N) N Date of pumping 5-2-11 Pumper IRs C. ABSORPTION FIELD DATA Date installed 4/20/2002 Soil rating (g.p.d./lt2 or tt2/bdrm) 0.8 Length 63 lt. Width 1_~5 ff. Gravel below pipe 0.5 ff. Wires properly protected (Y/N) _Y_ Casing height (above ground) 24 in. AT INSPECTION 5-2-2011 +3* lt. 5.8+ g.p.m. Eft. absorption area 945 it2 Monitoring tube Y Date of adequacy test 5/2/2011 Fluid depth in absorption field before test 0 in. Depression over field __N Results (Pass/Fail) Pass For 5 . bedrooms Water added 750 gal. New depth 0 in. Elapsed Time: <1 min. Final fluid depth 0 in. Absorption rate >= 750+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N__lf yes, give date --__z System type Bed Total depth 6._~5 ff. (Measured 5/2/11) D. LIFT STATION Date installed Size in gallons ~Pump on" level at in. "Pump off" level at __ Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOTTO: Septic tank/lift station on lot :tOO'+ Absorption field on lot :t00'+ Public sewer main 75'+ Sewer/sePtic service line 25'+ Animal containment areas 50'+ in. Manhole/Access (Y/N). High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots :tOO'+ On adjacent lots :tOO'+ Public sewer manhole/cleanout :tOO'+ Holding. tank 1,00% Manure/animal excrete storage areas :tOO'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Water main 10'+ Water service line :tO'+ Wells on adjacent lots :tOO'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line :to'+ Building foundation :tO'+ Water Service line :tO'+ Surface water :tOO'+ Curtain drain 50'+ (None Known) COMMENTS Absorption field 5'+ Surface water :tOO'+ Water main :to'+ Driveway, parking/vehicle storage Wells on adjacent lots 100'+ 10'+ *Artesian plug in wellhead. G. ENGINEER'S CERTIFICATION ! certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name KENNETH M. DUFFUS Date 5/12/11 COSA Fee $490.00 Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number SGS Ref.# 1111643001 Client Name ArcTcrra Engineering and Surveying Printed Date/Time 05/10/2011 13:29 Project Name/# WATER SAMPLE Collected Date/Time 05/02/2011 13:30 Client Sample ID Denaly B 1 L14 Received Date/Time 05/02/2011 14:30 Matrix Drinking Water Technical Director Stephen C. Ede PWSID 0 Sample Remarks: Allowable Prep Analysis Parameter Results LOQ Units Method Container ID Limits Date Date Init Metals by ICP/MS Arsenic ND 5.00 ug/L EP200.8 B (<10) 05/03/11 05/09/11 NRB Waters Department Total Nitrate/Nitrite-N 0.425 0.100 mg/L SM20 4500NO3-F B (<10) 05/04/11 AYC Microbiology Laboratory E. Coli Negative I 100mL SM20 9223B A 05/02/11 DLC Total Coliform Negative 1 100mL SM20 9223B A 05/02/11 DLC / LOT 13 BLK 1 LOT 15 BLK 1 dO2. LOT 1 2 BLK 1 77, ~ LOT 14 BLK 1 40.0' GARAGE 23,7' AC D/W DECK ~. 11.5' ~ EXISTING HOUSE 44.0' DECK BRICK PATIO GRAVEL WALKWAY SEPTIC --~ VENTS (TYP) LOT N89°44'53"W 20.00' COVERED SCREENED PORCH lA I ,'1 B-1 [--,-7 o < I I ANCHORAGE RECORDING DISTRICT AS-BUILT OF: DENALY SUBDIVISION LOT 14 BLOCK 1 PLAT 2000-12 SURVEY CERTIFICATION: I, John L. Schuller, have conducted a physical survey of this property as shown on this drawing and that the improvements situated thereon are within the property lines and no enchroachments exist other that noted. EXCLUSION NOTES: It is the owners responsibility to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. Under no circumstance should any information on this drawing be used for construction of fences, structures, improvements, or for establishing boundary lines. WORK ORDER NUMBER: DATE: 28, 2011 /JSCAmI"=50' E-MAIL: BY: CHECKED BYt GRID NUMBER: BOOK/PAGE: 11--01 9 DA~A~JLS/ ~o~ e= FND MONUMENT ~) = FND 5/8" REBAR W/YELLOW PLASTIC CAP (~ = FND 5/8" REBAR W/ALUMINUM CAP x~_~.M~L LAND Anchorage, Alaska 99508 (907) 227-1455 office (907) 274-4992 fax