Loading...
HomeMy WebLinkAboutTONJESS ESTATES BLK 2 LT 19Ton jess Estates Block 2 Lot 19 #051-832-11 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 Page 1 of 3 ON -SITE WASTEWATER INSPECTION REPORT Permit Number: OSP221369 PID Number: 051-832-11 Dwelling: X Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New❑ Upgrade Name Gregory Bjorgo ABSORPTION FIELD El Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 25388 Homestead Rd - Chugiak ❑ Other Phone 907-301-6840 Number of Bedrooms 4 Soil Rating Total depth from original grade 1.2 GPD/SF 7.2 / 10.7 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 3.2 / 6.7 Ft Gravel depth beneath pipe 4.0 / 4.0 Ft. Subdivision Block Lot Tonjess Estates 2 19 Fill added above original grade 0.3 / -0.2 Gravel length 50 Township Range Section Ft. Ft. Gravel width 5.0 Ft. Beds: Number of Lines N/A Distance between lines N/A Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 500 Ft2 1 N/A Ft. Well >100' >1 00' N/A N/A >25 TANK ❑ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Capacity Greer 1250 Gal. Surface Water >100' > 1 00' N/A N/A Material Plastic Number of compartments 2 Lot Line >5' >10' N/A N/A NA Foundation > 10' > 10' N/A N/A L TATION Manufacturer Capacity Remarks Trench constructed against grade per permit Gal. Measurements listed shallow end/deep end Alarm location Electrica by Installer PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Hiland Excavation Drainfield D3034 CO/MTD3034 Inspector B Schiller BENCH MARK (Assumed elevation) 100 ft Inspectiones: is' 6/13/23 2�d 6/15/23 Location and description 3'° 6/15/23 4" Top of conc slab for generator ON -SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp Conditional Approval: Date 4�0' •'gc0it i * 49 •n-t *�� Septic System Approved Date Z 20� " Benjachiller /1 '• rrsr S/ (I)��nG,'�rF f C2/1t3/242 •�������/ ,3 • . , . F�PROFESSI�Nt� lill4� Note: this approval does not include well permit requirements. /D. nc/nnm O% \Ze��t� TONJESS ESTATES, BLOCK 2 LOT 19 PERMIT # OSP221369 P_ ID # 051-832-11 LOT18A 10' WALKWAY) � i / ` / \�/ — \� -5`0' LO G x 5' WIDE, 4,' EFFECTIVE DE � H A SORPTION TRENCH MT3 \ \ z Co O / / //SLOT 19#; \\� / It/ / / \ C BM \\\\ OMT2 —� 1510 / / B J VFCO 520 / O CO _ C01 l 2C0 (EXISTING TO OLD FIELD) 53040� / �� A� / / 1250-GAL SEPTIC / ` / / j / -TANK W/ 25�-MANWAY 550560 E�13TERLY E OF INGREElSS-PESS EASXMENT — — —� �F_CORDF- AT BOOK 1'21 P)GE 09 / 570 TACT B1 LOT 20 v 580 N • i E : API L �ITRIC-�EIVIEN. T AFFECTING LOT 19 IS RECORDED AT � o/k�., AC3E 530;WHICH IS ViiRITTEN IN SUCH AN ANIBIGUOUS li! J iIVNER TF/AT IT 18lh•1POSSIBLE T O DELINE.ATEITS LOC,4TION ON THIS / F ,01EGE/) ' ENGINEERING \ ! / �>l OF A� ill PLAN AS -BUILT . •% 0 50 100 Benja i Schiller / FEET F 7;17"23 • � illFO PROFESSIONP��'�' C01 26.5 17.5 - MH 28.4 16.5 - SV 33.7 15.2 - 2CO 35.0 15.4 - DV 36.4 15.4 CO2 - 1 42.1 62.4 MT2 - 43.2 63.0 CO3 - 43.2 33.5 MT3 - 44.5 1 34.7 LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT DV - FLOW DIVERTER VALVE MH- MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE TONJESS ESTATES, BLOCK 2 LOT 19 PERMIT # OSP221369 PID # 051-832-11 99.7 LOW SIDE 103.1 HIGH SIDE FINISH GRADE ORIGINAL GRADE F- O 102.9 HIGH SIDE OE- 99.4 LOW SIDE FINISH GRADE U� ORIGINAL GRADE nn /-, 96.2 DRAINPIELD ROCK 96.2 92.2 92.2 50' NO GROUNDWATER 10/17/2022 83.9 H .�- wk 0 o ; :: ; PROFILE AS -BUILT /A. Ben Schiller �'F`�• CE 12592 (NO SCALE) ENGINEER 1 N G �®�_ R�FESC10 �, 1 OF•At P _ .0.: 49 TH SHANE A. HOLT ..- �m LS-6914 7p '-•---• pd o ,��o!essional �o NOTE: AN ELECTRIC EASEMENTAFFECTING LOT 1915 RECORDED AT BOOK 947PAGE530, WHICH IS WRITTEN IS SUCHANAMBIGOUS MANNER THAT IT 1S IMPOSSIBLE TO DELINEATE IT'S LOCATION ON THIS SURVEY. O ''' i WELL / ASPHALT DRII/EWAY '_3 ss I ' EASTERL YEDGE OF INGRESS -EGRESS EASEMENT RECOP,DEDATBOOK1521 PAGE509 LOF20 THEINFORMATIONHEREON ISFOR THE USEOFLENDINGINSTITUTIONSSPECIFICALLYTO SHOWANY CONFLICTSBETWEEN EXISTING STRUCTURESAND PLATTED LOT LINESAND/OR EASEMENTS,AND IS NOT TO BE USED FOR POSTT70NINGADDLTIONAL STRUCTURES IMPROVEMENTS, OR FENCELINES. EASEMENTS OFRECORD, OTHER THAN THOSEAPPEARING ON 77-IERECORD PLAT, ARENOT SHOWN HEREON ( UNLESS INDICATED) NOTE.' FENCELINESTHATMAYAPPEARONTHISDRAWINGARENOTTOBEUSEDTODETERMNE PROPERTYLINESORPOSMONADDITIONAL IMPROVEMENTS. ANYPAVING SHOWNHEREON MAYBEAPPROXIMATEDUETO FXCESSIVESNOWAND/OR ICE. LOTIS AS-BUILTSURVEY I" = 40' NO CORNERS SET THIS DATE I HEREBY CERTIFY THAT I HAVE PERFORMED A SURVEY OF THEFOLLOWING DESCRIBED PROPERTY L0T19 BLOCK2 TONJESS ESTATES (PLAT82-59) ANCHORAGE RECORDING DISTRICT, ALASKA, AND THAT THE VISIBLEIMPROVEMENTS SITUATED THEREONAREWITHIN THEPROPERTYLINESAND NO VISISLEENCROACHMENTS EXIST OTHER THAN NOTED. DATEDATANCHORAGE,ALASKA THIS 10 TH DAYOF AUGUST , 2023 9309GROVERDRIVE ANCHO9,4GEAK 99507 15577 226-46 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 hftp://www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP221369 Work Type: Septic Upgrade Tax Code Number: 05183211000 Site Legal Address: TONJESS ESTATES BLK 2 LT 19 G:1462 Site Mailing Address: 25388 HOMESTEAD RD, Chugiak Owner: BJORGO GREGORY J Design Engineer: FORGE ENGINEERING This permit is for the construction of: K Disposal Field Rf Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: t»cnt S J fi Department Lot Size in Sq Ft: Total Bedrooms: V?_9 / Z. Z 2 A2e CJ/'Z-a5- / 5/7O Z3 cilt 44307 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: I. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Cc ;�X I -Des,, t �1a+� QAI(10 .l Je / / /ZR/2'L Veronica Pope RGE 2022.09.29 Received By: "" ` 08:50:28 - Issued By: Date: Date: / 2 20 Z Z 4 M UHUPAUTY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 051-832-11 Property owner(s) Gregory Bjorgo Day phone Mailing address 25388 Homestead Road, Chugiak, AK 99567 Site address 25388 Homestead Road Legal description (Sub'd., Block & Lot) Tonjess Estates, Block 2 Lot 19 Legal description (Township, Range & Section) Lot Size 44,307 Sq. Ft. Number of Bedrooms 4 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank Upgrade RDuplex ❑ (D) Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 6q6- Waiver Fees: Date of Payment: 1 �512Z /� Date of Payment: Receipt Number: 63IC( Id- 'J Receipt Number: Permit No. 05 e2,,;,- 13 (O� Waiver No. Perm it App__- :'_.,:c: September 13, 2022 Municipality of Anchorage On-site water and Wastewater REVIEWED FOR CODE COMPUANC OSP229369, Curtis Townsend, 09,29 PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) FORG£CIVIL.COM MOA Development Services, On -Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Tonjess Estates Block 2 Lot 19 - 25388 Homestead Rd Septic system design Dear On -Site Services Engineer: The owner of the above lot wants to replace the aging septic system on his lot, so we are submitting this permit application for the construction of a new septic system. The attached site plan identifies the location of the home as well as the proposed septic location. No conflicts exist between this proposed system and any other well or septic system, whether on this lot or adjacent lots. The ground surface on the lot slopes moderately toward the road, with a flatter section where the home and existing septic system is and a steeper area in front toward the road. Contours are shown on the site plan showing the grade and direction of slopes. We are proposing to place the septic alongside the existing trench, with minimum 8' separation. One important point is that the trench is along the side of the home, and runs perpendicular to the slopes on the property. There is significantly more cover on the uphill side, as the trench must be set level. Our design provides sufficient cover on the shallow end of the slope, while allowing for the trench to be set 4' deeper on the deeper end into the slope. We have specified that the maximum depth must is 11', maintaining required separation to possible bedrock or groundwater. There are no slopes greater than 25% within 50 feet downslope of either the primary or alternate site. Wells on this and adjacent lots are shown. The new system will be a minimum of 100' from all wells and surface water, and more than 5' away from the septic tank. Stormwater drainage will not impact this septic system. Please refer to the attached test hole log, plan and profile pages for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Benjamin Schiller, PE TONJESS ESTATES, BLOCK 2 LOT 19 co LOT 18A 10' WALKWAY —50' LONG x 5' WIDE, 4' EFFECTIVE / Co / / �? / �/ i \ DEPTH ABSORPTION TRENCH `MAINTAI8' SEPARATION FROM EXISTING \TRENCH AND 10' \ \ SEPARATION FROMIPROPERTY LINE //X13.5 / i 151 / / POSSIBLE MEA EASEMENT LOCATION I //� / ADV520 0 \ y 530 �/ / I ��j / / NEW 1250 -GAL /540` / / SEPTIC TANK W/ 20" , I / / MANWAY— 550 DECOMMISSION OR, r / REMOVE EXISTING 560 i - SEPTIC TANK PER EEZ'TERLY Eh�E OF INGRESS -EGRESS EASEi14ENT rF-CORD�[; AT BO01•: 1X21 PAGE S09 570 TRACT BI-- /LOT 20 \ % 11 , E :.AIV �-L�OTRIC �-�`EMEi\!T AFFECTING LCAT -79 IS ,RECORDED AT / / fit Oki A ;E SCO,/WHICI� rS bYRITTEN JN SUCH AN APOBIGUOUS n•,a1INER T; -/AT 1T 0IMPOSS/BLE TO"DFLINEATE ITS Li?CATION ON THIS ' GE/ 5l IRVEl / ENGINEERING NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND OF A ll PROPOSED SEPTIC SYSTEM �,�p'''•••••''•�.F91�� CO - CLEANOUT ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2C0 -DOUBLE CLEANOUT • • • • • • • • • • PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO -FOUNDATION CLEANOUT • .. SYSTEMS. DV - FLOW DIVERTER VALVE / Benja i Schiller / MH -MANHOLE P .• .: / 0 50 100 �c .• CE 2592 �� i MT - MONITORING TUBE OP •,��*0 FEET 1 ROFESSIONP .�mw SV - SEPTIC VENT l\ PROFNV �' 1 =50 TH - TEST HOLE TONJESS ESTATES, BLOCK 2 LOT 19 c o 1 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 1 TO 2 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5.0' WIDE TRENCH SYSTEM 1,250 -GAL GREER SEPTIC TANK 600 GPD / 1.2 GPD/SF /5' WIDE * 0.50 RED. FACTOR = 50.0 LF TRENCH REQUIRED (50 LF SPECIFIED) USING A BENCHMARK OF 100.0 @ BTM CORNER OF HOUSE: SHALLOW END (EXISTING GRADE 98.33) BOTTOM OF TRENCH: (91.83) 6.5' BELOW GRADE (MAX DEPTH IS 13' BELOW GRADE) FLOW LINE ELEVATION: (95.83) 2.5' BELOW GRADE TOP OF TRENCH: 1.0' ABOVE GRADE N M/ GEOTEXTILE FABRIC 4" PERFORATED PVC (HOLES DOWN) DRAINFIELD ROCK DEEP END (EXISTING GRADE 104.21, 5.88' HIGHER): BOTTOM OF TRENCH: (91.83) 12.38' BELOW GRADE (MAX DEPTH IS 13' BELOW GRADE) FLOW LINE ELEVATION: (95.83) 8.38' BELOW GRADE TOP OF TRENCH: 0.5' ABOVE GRADE TYPICAL TRENCH SECTION (NO SCALE) NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE & OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY E N G I N E E R I N G of *-.-"49 TH �Q ••:yt . ...... ••• Benja • in Schiller 1 FG CE 12592 c� 0 FESSIONP�4 0 0 1 N v U 0 . 1 W ,q: o CC � co 00 �u I I I n Iry I LU I (D o �} Z LU LO I I 1 I C) N I w LU 0 c\j 7- 0 0 0 w J LL 0 2 U Z W Q' F- ARW it ! z / • • L N •, O U Cn u'J N N cu u L .w TCT . ._ f� • LL r m .• zk-z? % 2, , GE SOILS LOG AND PERCOLATION TEST E N G I N E E R I N G LEGAL DESCRIPTION: TONJESS ESTATES, BLOCK 2 LOT 19 PERFORMED FOR: GREGORY BJORGO DATE: 8/25/22 PARCEL ID#: 051-832-11 DEPTH TEST HOLE 1 (feet) INET NO DATE READING START TIME TIME DEPTH TO WATER NET DROP OB (MINUTES) (INCHES) (INCHES) 2 --- _ 9/1/22 1 10:49 10 0 5— 16 5— 16 3 t ' . PERC TEST LOCATION 211:02 10 0 511 511 4 3 11:14 10 0 4 L24 L2 16 5 4 11:26 10 0 416 4 i6 6 r 5 11:37 10 0 4L2 4L2 16 `� GM (SILTY SANDY GRAVEL) 6 11:48 10 0 4 L 4 L 7 . . g f 4 6" DIAMETER TEST HOLE PRESOAKED PRIOR TO TESTING 9 PERCOLATION RATE: 2.1 (MIN/INCH) lo SITE PLAN 11 12 13 ". 14 15 16 • •; 17- 7 NO WAS WATER ENCOUNTERED? - IF YES a WHAT DEPTH? NONE NONE DEPTH TO WATER AFTER MONITORING 9/1/22 10/17/22 DATE OF MONITORING COMMENTS: USCS SOIL CLASSIFICATION WAS VISUALLY DETERMINED TECHNICIAN: L. TIDWELL DEPTH (feet) 1- 2- N .1 lJ 7 8 9 10 11 12 13 14 15 16 17 18 1 Co -*::�l GE SOILS LOG AND PERCOLATION TEST ENGINEERING LEGAL DESCRIPTION: TONJESS ESTATES, BLOCK 2 LOT 19 PERFORMED FOR: GREGORY BJORGO DATE: 10/13/22 PARCEL ID#: 051-832-11 TEST HOLE 2 NO WAS WATER ENCOUNTERED? IF YES @ WHAT DEPTH? DEPTH TO WATER AFTER MONITORING DATE OF MONITORING NET TIME DEPTH To NET DATE READING START TIME (MINUTES) WATER (INCHES) DROP (INCHES) 6" DIAMETER TEST HOLE PRESOAKED PRIOR TO TESTING PERCOLATION RATE: N/A (MIN/INCH) SITE PLAN TECHNICIAN: L. TIDWELL COMMENTS: TEST HOLE DRILLED AND LOGGED FOR SEPARATION TO IMPERMEABLES ONLY OB GM (SILTY SANDY GRAVEL) 3 _:,_: _ ._ CL (CLAY) NO WAS WATER ENCOUNTERED? IF YES @ WHAT DEPTH? DEPTH TO WATER AFTER MONITORING DATE OF MONITORING NET TIME DEPTH To NET DATE READING START TIME (MINUTES) WATER (INCHES) DROP (INCHES) 6" DIAMETER TEST HOLE PRESOAKED PRIOR TO TESTING PERCOLATION RATE: N/A (MIN/INCH) SITE PLAN TECHNICIAN: L. TIDWELL COMMENTS: TEST HOLE DRILLED AND LOGGED FOR SEPARATION TO IMPERMEABLES ONLY OF s4 49 TH` SHANE A. HOLT I&,LS-6914 O'ession3� Lsoa NOTE. ANELECTRICEASEMENTAFFECTINGLOTI9ISRECORDEDATBOOK947PAGE530, WHICHIS WRITTEN IS SUCH ANAMBIGOUS MANNER THAT IT IS IMPOSSIBLE TO DELINEATEIT'S LOCATION ON THIS SURVEY. i / / / 0 / Op / / / / / / / / / / WELL* / ASPHAL T DRIVE6UAY i / / J / EASTERL YEDGEOFINGRESS-EGRESS EASEMENT RECORDED AT BOOK 1521 PAGE509 I A / / LOT20 / / /i /r / / 2S S sr�p„ X41 �o FP \ c O�G� LOT18 THE/NFORMATION HEREON IS FOR THE USE OFLENDING INSTITUTIONS SPECIFICALL YTO SHOWANY CONFLICTS BETWEEN EXISTING STRUCTURESAND PLATTED LOT LINESAND/OR EASEMENTS,' AND IS NOT TO BE USED FOR POSITIONINGADDITIONAL STRUCTURES, IMPROVEMENTS, OR FENCELINES EASEMENTS OFRECORD, OTHER THAN THOSEAPPEARING ON THE RECORD PLAT, ARE NOT SHOWN HEREON (UNLESS INDICATED) NOTE' FENCELINES THAT MAYAPPEAR ON THIS DRAWING ARE NOT TO SE USED TO DETERMNE PROPERTYLINES OR POSITIONADDITIONAL IMPROVEMENTS. ANYPAVING SHOWN HEREON MAYBEAPPROX/MATE DUE TO EXCESSIVE SNOWAND/OR ICE ASBUILTSURVEY 1" =40' NO CORNERS SET THIS DATE I HEREBY CERTIFY THA T l HA VE PERFORMED A SURVEY OF THE FOLLOWING DESCRIBED PROPERTY LOT19 SLOCK2 TONJESS ESTA TES (FLA T82-59) ANCHORAGERECORDING DISTRICT, ALASKA, AND THAT THE VISIBLE IMPROVEMENTS SITUA TED THEREON ARE WITHIN THE PROPERTY L INES AND NO VISISL E ENCROACHMENTS EXIST OTHER THAN NOTED. DATEDATANCHORAGE,ALASKA THIS 9 TH DAYOF AUGUST , 2022 15577 226-46 HOLT bI ND SURVEYING 9.309 GROVER DOVE ANCHOR9GEAK 99507 223-8615 72-013 (Rev. 3/78) MUNICIPALITY OF ANCHORAGE _-1.1- "�;(;�DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ! ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 --- - ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME A .k S n(±0NST CTION - APPLICANT } X {}(X)JFX CO lus—T PH NE 8._ 767 NEW ■ UPGRADE MAILING APD no .6Q� co r. �% 9 // !'mss /`, %..5---7, G LEGAL RIPTION .---_ L OS / 9' ,6 Z / 0�./ e s s '7 -- LOCATION Z �� N /e / u) NO. OF BEDRC}Ofy�S SEPTIC TANK DISTANCE TO: We /� r ( J Absorpuory prep ! G C/` Dwelling 11� PERMIT w/`7` / -7 C7 Manufacturer G/� J Ask, / No. of compartments 2 G Lo�,city L allons IF HOMEMADE: Inside length Width Liquid depth GSU O Y J.9Z S� F DISTANCE TO: Well Dwelling PERMIT NO. Manufacturer— Material Liquid capacity in gallons TILE ' fl J-NF1Ei0 TRENCH DISTANCE TO: Well // 7 / Foundy72lyp� ( vtp�fJines/ Nearest lo)Jyns— / PEHMI',v5;// 7 54 - /' 7` No. No. of lines / Length of.7/ Total Ienn9 iJ Trenchg6 (� inches Distancebetweenlinest Top of the to finish4rade / g Material beneath the ¢g ! rinches gj QTotal effecti a abso ion tea SEEPAGE PIT Length Width Depth PERMIT NO. Type of crib Crib diameter t / r/ epth Total effective absorption area DISTANCE TO: Well Building foundation Nearest lot line J W 3 CI I ept (� Driller Distance to lot line PERMIT NO. DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER PIPE MATERIALS iV C I =willw_ ==_■ 1' II �■— 1 SOIL TEST RATING %� t fra 1 � ,�I �■ INSTALLER D` A /'+ ST l/ I 1111111111M= nl.�■■ REMARKS IME fli 1. OF—AtePts afir .v.lidiiiiv"S"::::::.-04.4i 1 '••R.. ;35 f J J v / . err+ 'PT. • OF ..." IEA .. .$— H -1 011 Art4 c IF1�1� 1 N: -INT .L F.•Jttl ILO4I 1:4 % 0 I 1 1284 er . 6-; : f4o. 14.57-8 ,: ,;� `t.,,,°F. -- lC'JVD 1' a. • �'} a- SRR 793. • APPROVED . 8 it '‘'T tbitiiI\ICZeINI:4 D•410 ii.:;QLE nIVER, ALASKA T:577 rAf PH. 694-2970 �/ ,%�[� /U 72-013 (Rev. 3/78) MIJN i C i PAL I -r OE AINICI-1011A1BE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L STREET, ANCHORAGE, AK 99501 264-4720 MIN —SITE .S EWE R $c WELL_ PERM I 11 - PERMIT PERMIT NO: 840674 DATE ISSUED: 08/08/84 APPLICANT: A & S CONSTRUCTION ADDRESS: % S&S ENGINEERING EAGLE RIVER, AF; 99577 CONTACT PHONE: 688-9675 LEGAL DESCRIP: LOT SIZE: MAX BEDROOMS: SUBDIVISION: TONJESS SECTION: 2 TOWNSHIP: 15N 44307 (SQ.FT. OR ACRES) 4 Listed below•are the options available to system. Choose the option that best fits LOT: 19 RANGE: 1W BLOCK: 2. you in designing your septic your site. DEPTH TO PIPE BOTTOM (FT.) GRAVEL DEPTH (FT.) TOTAL DEPTH (FT.) GRAVEL WIDTH (FT.) GRAVEL LENGTH (FT.), TANK SIZE (GALS) SOIL RATING (SQ.FT./BR) lr 1- 1 4.0 4.0 8.0. 2.5 75.0 1,250.0 ** 150 ** TANK MUST HAVE AT LEAST TWO COMPARTMENTS ER E D 4.0 0.5 • 4.5 22.0 41.0 1,250.0 ** 150 W.. DRAIN 4.0 3.5 7.5 5. 0 65.0 1,250.0 ** 150 I certify that: 1. I am familiar with the requirements for on-site sewers and wells as.set forth by the Municipality of Anchorage (MOA) and the State of Alaska. 2. I will install the system in accordance with all MOA codes and regulations, and in compliance with the design criteria of this permit. I will adhere to all MOA and State of Alaska requirements .for the set back distances from any existing well, wastewater disposal system or public • sewerage system.on this or any adjacent or nearby lat. 4. I understand that this permit is valid for a maximum af. 4 bedrooms and any enlargement will require an additional permit. IF A LIFT STATION IS INSTALLED IN AN AREA COVERED•'BY MOA BUILDING CODES, THEN (1)' AN ELECTRICAL PERMIT AND INSPECTION MUST BE OBTAINED; (2) AS-BUILTS WILL NOT BE APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT; AND (3) THE ELECTRICAL WORK MUST BE DONE BY A LICENSED ELECTRICIAN. SIGNE5)62141, DS APPLICANT: A && S RUCTION ISSUED BY DATE: 9ig*_' DATE: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264.4720 SOILS LOG - PERCOLATION TEST PERFORMED FOR: 4 ( ri S CoNSr)vJc'-%O&f LEGAL DESCRIPTION: 10 11 12 13 ORCP.(y , G sAAtif iS/LT s -e) 4/eic C-I12l4vy cL acr7-oiM of 14 15 16 17 18 4 •4`‘"•111 .bort A..1,/4w 19 ■ L No. 14574 20 �spRol?rc>ar4P COMMENTS PERFORMED BY: 72-008 (6/79) SOILS LOG ❑ PERCOLATION TEST DATE PERFORMED: 8/ti LK Z 7i c s'S 6s -r- 1 E PLAN ■llaii111lii1111111■ 111111111111111111111111121111 11111111111111111111111111 1111111111111111111111111/11111 11111111111111111111111 1111111111111111111111111111 SLOPE WAS GROUND WATER S ENCOUNTERED? L IF YES, AT WHAT DEPTH? 0 P E Reading Date Gross Time Ne Time Depth to Water Net Drop i.-yirl -- • PERCOLATION RATE TEST RUN BETWEEN a8 EVGINexI�lNa rt� s>as �a CERTIFIE FT AND (minutes/inch) FT DATE: Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL cg90_ FOR A SINGLE FAMILY DWELLING _04,3 Parcel I.D. 051-832-11 1. GENERAL INFORMATION Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency 'Mailing address Real Estate Agent Mailing address COSA# 0 Se13IU49 Expiration Date: (9 — ) 3 TONJESS ESTATES- BLOCK 2 LOT 19 25388 HOMESTEAD ROAD *CHUGIAK, AK 99567 KRISTIN MILLER Day phone 301-8936 25388 HOMESTEAD ROAD *CHUGIAK, AK 99567 Day phone Day phone Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site Individual Holding tank Community On-site Public Sewer • The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that ray investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. t further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation. GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. 5. DSD SIGNATURE Approved for Disapproved. Conditional approval for 14 bedrooms. Date OFA bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other (Rev 11/05) Original Certificate Date: 3 ~�2 g-/ 3 Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: TONJESS ESTATES; BLOCK 2, LOT 19 Parcel ID: 051-832-11 A. WELL DATA *PER ARCTIC PUMP AND WELL INSPECTION. SEE ATTACHED. **CASED I� BEDROCK ASiuM Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) NO Date completed 1984 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth *182 ft. Cased to **29.5 ft. Casing height (above ground) 12+ in. FROM WELL LOG AT INSPECTION Date of test NO WELL LOG 6/29/12 Static water level ft. 93 ft. Well production g.p.m. 2.17 g.p.m. WATER SAMPLE RESULTS: —7 Coliform 0 colonies/100 ml. Nitrate T• 3Omg./L. Collected by: GEG. Ltd. Arsenic:N O ug./L. Date of sample: _ 3/ 7 i 3 B. SEPTIC/HOLDING TANK DATA r Tank Type/Material Tank size 1250 gal. SEPTIC/STEEL Number of Compartments 2 Foundation cleanout (Y/N)IYES Depression over tank (Y/N) NO Date of pumping !.z 3) 1 D- Pumper f� ' 5 C. ABSORPTION FIELD DATA Date installed 9/28/84 Cleanouts (Y/N) YES High water alarm (Y/N) N/A rYi el /t y *BELOW EXISTING GRADE TO BOTTOM OF MT I Date installed 9/28/84 Soil rating (g.p.d./ft2or (/bdri 150 Length 75 ft System type TRENCH Width 2.5 ft. Gravel below pipe 4 ft. Total depth *9.6 ft. Eff. absorption area 600 ft2 Date of adequacy test 6/29/12 Monitoring tube **YES Results (Pass/Fail) PASS Fluid depth in absorption field before test 11.5 in. Water added 630 gal Elapsed Time: 120 min. Final fluid depth******24in. Depression over field NO For 4 bedrooms New depth ***29.5 in. Absorption rate >= 600+ Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date **MONITORING TUBE ONLY EXTENDS 2.25' INTO EFFECTIVE. ***2.5" ABOVE .INVERT. ****3" BELOW INVERT. WONT/SUMP AT WEST END OF TRENCH APPEARS TO NOT EXTEND TO THE BOTTOM OF SYSTEM, LIQUID LEVEL HOWEVER MATCHES EASTEND OF THE DRAINFIELDS MT/SUMP. g.p.d. D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump offlevel Datum Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: 100'+ Septic tank/lift station on lot Absorption field on lot Public sewer main 100'+ N/A Sewer /septic service line 25'+ Animal containment areas 50'+ Manhole/Access (Y/N High water alarm level at in. Meets alarm & circuit requirements? On adjacent lots 100'+ On adjacent lots 100'+ Public sewer manhole/cleanout N/A Holding tank N/A Manure/animal excrete storage areas 1001+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Wells on adjacent lots 100'+ Water service line 10'+ Surface water SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water service line 10'+ Surface water 100'+ Curtain drain F. COMMENTS NONE KNOWN Wells on adjacent Tots 100'+ 100'+ Water main N/A Driveway, parking/vehide storage 10'+ G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems am in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date -7/241f2 COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Community Development Department Development Services Division On -Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Nitrate Advisory Certificate of On -Site Systems Approval # 131099 A Certificate of On -Site Systems Approval inspection and test of potable water was recently conducted on the well water supply on Block 2, Lot 19 of Tonjess Estates subdivision. This inspection revealed a nitrate concentration of 7.3 milligrams per liter (mg/L) was reported for the property's well water sample. The Environmental Protection Agency (EPA) has established a maximum contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While private wells are not subject to this regulation, EPA standards are based on existing health information and can therefore be used to gauge the relative quality of water from private wells. Please see the attached "Nitrate Fact Sheet" for important information regarding nitrate. This advisory must be attached to all copies of the subject Certificate of On - Site Systems Approval. ARCTIC PUMP & WELL INC. Jim Sullivan PO Box 770197 Eagle River, AK 99577 (907) 688-2510 (907) 258-2510 (907) 745-2510 apw,l gei.net Pump Installation Log Well Drilling Permit Number: SW Parcel Identification Number: Date of Issue: Arctic Pump & Well, lnc. Page l of I Legal Description:Tonjess Est Lot:19 Block:2 Property Owner Name & Address: Kristin Miller PO BX 671167 rhnaialr Au QQSA7 Pump Installation Date: 7-912 Pump Intake Depth Below Top of Well Casing:136 Feet Pump Manufacturer's Name: Red Jacket Pump Model: 13 ad Pump Size:1/2 hp Pitless Adapter Burial Depth:10 feet Pitless Adapter Manufacturer's Name: Harvard Pitless Adapter Installer: U/K Well Disinfected Upon Completion? Yes Method of Disinfection: Chlorine Comments:Static 91' Liner 29.5' Perforations 159-182 Depth 182' MOA Seal and conduit installed Pump Installer Name: Arctic Pump & Well, Inc. Arctic Pump & Well, lnc. Page l of I 0 • 4'X7' Rtck copy .,sr F. GPC AS -BUILT -a ] hereby certify that I have surveyed the following described property- 1 -et i 7, !reek -ton Sr..r, r t s,: a_ . ?" i t ill R u S/Li, Anchorage Recording Precinct, Alaska; and that the improve- ments situated thereon are within the property lines and do not overlap or encroach on the property lying adjacent thereto, that no improvements an property lying adjacent thereto encroach on the premises in question and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated at Eagle River, Alaska this. _ . A., „r a 192 ROBERT C. JOHNSON SCALE: Registered Land Surveyor No7880-LS l = _ Box 77-0456, Eagle River, Alaska 99577 Phone 907) 694-2543 r • MUNICIPALITY OF ANCHORAGE (" DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date September 5, 1986 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Lot 19 Block 2 Tonjess Estates T15N R1W Sec. 2 Location (address or directions) Anchorage (b) Applicant Name Graham Young Telephone: Home N/A Business 276-2761 Applicant Address 2600 Cordova St. Anchorage,Alaska 99503 (c) Applicant is (check one): Lending Institution 0 ; Owner/builder ❑ ; Buyer 0 ; Other ® (explain). realtor (d) Lending Institution Alaska Mutual Bank Address (e) Real Estate Company and Agent Re/Max Graham Ynung Address 2600 Cordova St. Anchorage, Alaska . 99503 ' 6 i... "SO :0 1• Telephone 333-3011 t ,r: • • 1. (1) Telephone 276-2761 Mail the HAA to the following address: pickup by engineer 2. TYPE OF RESIDENCE Single -Family El Multi -Fa lily 0 Other Number of Bedrooms 3. WATER SUPPLY Individual Well 0 Community 0 Public 0 Note: If community well system, must have written confirmation from the State Department of Erivironmental Conservation attesting to the legality and status. 0,„;;;;;, `1 4. • SEWAGE DISPOSAL Onsite ® Public 0 Community 0 Holding Tarikloi; I' L Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 (11/84) 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DA i A AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Telephone Address EAGLE.RIVERGINEERR4GSERVICES Date 9/ '1./Ce EAGLE RIVER, AK 99577 P. 0. BOX 773294 694-5195 :,,�,� Or Ai Atilt, . .• ,. r7r..4 e. �� ��.GO�PO.V'II SAG ,.,`.,. e; Yt •'•L:., . t.A : L.. A.5urera j +T•��{ C4 **• `.6 C.� .n �e iti)N ,. C'1 G c.:... -.:*.:1::, VnGrc o - y ti �;.so 6. DHEP APPROVAL Approved for "7 bedrooms by Approved Disapproved Terms of Conditional Approval • 11!/1/ ^�•, ...CAUTION The Muncipality of Anchorage Department `of, •Health and Environmental Protection (DHEP) issues Health Authority • Approval certificates based solely upon the represei tatipps given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state re'qui'rements. Employees of DHEP.do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 t11/84) •/,) T y• MUNICIPALITY OF ANCHORAGE �1 DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY - (D�`� 264-4720 Application Date Sentember 5 . 1986 1. GENERAL INFORMATION c�1� (a) Legal Description (include lot, block, subc&Ision, section, township, range) Lot 19 Block 2 Ton.iess T15N R1W Sec.2 Location (address or directions) Anchorage (b) Applicant NameCraham Young Telephone: Home 276-2761 Business N/A Applicant Address 2600 Cordova St Anchorage , Alaska 99508 (c) Applicant is (check one): Lending Institution O ; Owner/builder 0 ; Buyer 0 ; Other ® (explain); realtor (d) Lending Institution Al aska Mutual Bank Address 1 :.. •'11 'II s• Telephone X33-3011 •• 1• (e) Real Estate Company and Agent ReMaX Graham Ynting (f) Address 2600 Cnrdnva Anr•hnrag- r Alaska 99503 Telephone 276-2761 Mail the HAA to the following address: pickup by engineer 2. TYPE OF RESIDENCE Single-Family121 Multi -Family 0 Other Number of Bedrooms 3 3. WATER SUPPLY Individual Well ® Community 0 Public 0 Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the'legality and status. 4. SEWAGE DISPOSAL Onsite ® Public 0 Community 0 Holding Tank 0 Note: if community well system, must have written confirmation from the State Department of Environmental Conservation ; attesting to the legality and status. Page 1 of 2 72-025 (11/84) ENGINEERING FIRM PROVIDINu INSPECTIONS, TESTS, FILE SEARCH, DH I A AND INFORMATION • As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Telephone Address Date EAG, F RIVER ENGINEERING SERVIGEe EAGLE RIVER, AK 99577 P.C. BOX 73294 694-5195 6. DHEP APPROVA Approved for bedrooms by Approved Disapproved Terms of Conditional Approval : 0 r1-,{: : e.,_•.... --....,„ i3 C ('1 (1,• 1^�',3,' ii �;c--- �F. , - Engineer's Seal ( pOO°OCJOC o •1 0•eY.••0 1 -I :. _ .0 -It i�00 Yb Y•• ` t ; G.-,• �n L_ !s A. E C I •c rtl ' `V <` CPA D so CE.6736 �� " •C ~c.,, < �ao .• �"•('V Pr's• 00.0; •,a•' 2�aP Z^, „ 0FESS,..;� Conditions Date //�- CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions In order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is Issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (11/84) _r A. WELL DATA fl MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description. o f' /9 _-1'1441-e-r 7-/s- A/ 2 rw Sec Well Classification P'eir/A TC 1f A, B, C, D.E.C. Approved (Y/N) 44 Well Log Present (Y/N) A1 Date Completed /9."' 4-rs-.., e.,C Yield Z Gee., res Ye -c.4" Total Depth *leg A Cased to fya °' bedc`aDepth of Grouting X14 Static Water Level 9y 'b5'//.... 7'r, c� e'v";'s Pump Set At rte'" Casing Height Above Ground y� �� Sanitary Seal on Casing (Y/N) i Electrical Wiring in Conduit (Y/N) / Depression Around Wellhead (Y/N) N Separation Distances from Well: To Septic/Holding Tank on Lot tic` ' • On Adjoining Lots +/et ' To Nearest Edge of Absorption Field on Lot / 3.1' • On Adjoining Lots 'f /`C,' To Nearest Public Sewer Line w/+ To Nearest Public Sewer Cleanout/Manhole A/4 To Nearest Sewer Service Line on Lot Water Sample Collected by E4fli 2•� �.K .✓eorrf ; Date -5- S Water Sample Test Results S4) 's r5c4to .y &e// //0.5 No7` Q✓4, 746/e b.ai/ce- Comments e ep C4Seei •*4,' or CjrrJGLi ,4S7ar7I-t . we// 1/cS B. SEPTIC/HOLDING TANK DATA Date Installed V4F.y Size /•)S" S4 / No. of Compartments Standpipes (Y/N) % Air -tight Caps (Y/N) Y Foundation Cleanout (Y/N) - Depression over Tank (Y/N) N Date Last Pumped 7/-v6 Pumping/Maintenance Contract on File (Y/N) ^'/4 • for Holding Tank High -Water Alarm (Y/N) 7✓,/4 Separation Distances from Septic/Holding Tank: To Water -Supply Well r'"vo ' To Building Foundation /v / .."//4 Temporary Holding Tank Permit (Y/N) N�4 To Property Line '/O To Disposal Field 3`/ / To Water Main/Service Line i'/e ' To Stream, Pond, Lake, or Major Drainage Course / 24 Comments Page 1 of 2 72-026(11/84) C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata J'S D r�' 2 Type of System Design ,/may Date Installed Width of Field 3a Length of Field 7-5— Ir / Square Feet of Absorption Area Coo Depth of Field 8 9 Gravel Bed Thickness Standpipes Present (Y/N) Y Depression over Field (Y/N) Date of Last Adequacy Test V.r Results of Last Adequacy Test .->~ fe 74.- v .Liq;.e. Separation Distance from Absorption Field: To Water -Supply Well "3? / To Property Line To Building Foundation / 7 To Existing or Abandoned System on Lot /V/q ; On Adjoining Lots 1-34 To Water Main/Service Line 470 To Cutbank (if present) NV4 To Stream/Pond/Lake/or Major Drainage Course Nuc To Driveway, Parking Area, or Vehicle Storage Area Comments 5tw..•I,'1 J re 147"k/45 D. LIFT STATION ,- Date Installed Dimensions Size in Gallons Manhole/Access (Y/N) "Pump On" Level at "Pump Off" Level at High Water Alarm Level at Vent (Y/N) Tested for Pumping Cycles during Adequacy Test. Meets MOA Electrical Codes (Y/N) Comments •• Check Permitted Bedroom Rating Against HAA Request •• I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed - Date 0i/ere Company fi /e/G' s' ' MOA No. Sr a6S Receipt No 4,00/ 0 0 0 C Date of Payment Amount. S C Page 2 of 2 72-026 (11484) re op,* c.. lr • — ,,,"••••‘'S * Or •�: .Q S� .4 t1 61a1,r's Seal .0 ••••..... - u-- - - Y..Ouub.Y.. s Louis A. Butera !iJ'>F•.• keori CE.6736 .✓ e g g �a�w�•�:5�.�A� .v