HomeMy WebLinkAboutTIMBERLUX #3 BLK F LT 2Ti*mberlux #3 Block, F Lot 2 #018-271-87 Municipality of Anchorage Development Services Department <~ Building Safety Division 5 e * Y On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page of www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SWO10274 PID Number: 018-271-87 Name: JAMES MCLIN Wastewater System: ❑ New ® Upgrade Address: ABSORPTION FIELD 14900 Lon b w Dr. Anchora a AK. 99516 Phone: Number of Bedrooms: 345-2217 4 Deep Trench O Shallow Trench ❑ Bed ® Mound ❑ Other: LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 1.2 GPD/Ftp 0.0 Ft. Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: F 2 Timberlux #3 +1.0 above grade Ft. 0.5 Ft. Township: Range: Section: Fill added above original grade: Gravel Length: 1.5-1.25 Ft. 54 Ft. Well: F1 New ❑ Upgrade Gravel width: Number of lines: Distance between lines: 20 Ft. 2 16 Ft. Classification (Private, A, B, C): Total Depth: Cased to: Total absorption area: Pipe Material: Existing Ft. Ft. 1080 Fe D3034 & F810 Driller: Date Drilled: Static Water Level: Installer: Date Installed: Ft. Owner install 6/16/2003 Yield: Pump Set at: Casing Height Above Ground: TANK GPM FL Ft. SEPARATION DISTANCES ® Septic ❑ Holding ® S.T.E.P. ❑ Other: To Septic Absorption Lift Holding Public/PrivateManufacturer: apac ty: From Tank Field Station Tank Sewer Line Anchorage Tank 2000 Gal. Well 100'+ 100'+ NA NA 25'+ Material: Steel Number of Compartments: 2 Surface Water 100'+ 100'+ NA NA Z LIFT STATION Lot Line 5'+ 10'+ NA NA Size: 2000 Gal. Manufacturer: Orenco Foundation 5'+ 10'+ NA NA "Pump on" level at: 44" in. 'Pump off" at: 42" in.4$" High water alarm at: In. Curtain Drain NA *50'+ NA NA Pump Make & Model Electrical Inspections performed by: Franklin 24 5040117-1/2h Remarks: BENCH MARK Organics removed from bed area and Location andDescription: replaced w/ sand to bottom of bed, Top N.W. corner of concrete step Assumed Elevation: depth of sand varies from 1' to 3'. 100 Ft. Engineer's Stamp r► w Inspections performed by: KND Engineering, Inc.Dates: 1St 6/16/2003 r't.•�r 1 •�* j r�aa• ••ye••a•NNo N•••-../ 2nd 6/1712003 Development Services Department Approval3r '7/1710 atom** 0 K>, Reviewed and approved by: Date:r� 8 0 1 / 0 si 116 �$ c� " 12/00) oo.,0000ftC��.: 9.o �(Rev. AS—BUILT SYSTEM DETAILS/SITE PLAN Permit SWO10274 TIMBERLUX #3, BLOCK F, LOT 2 PID#018-271-87 -------------------------------------------- MANYTELL AVE, I +ND o� ELS 0.AOSu' 500 Ey,S51iNG O�.IEW AY c � Ia- GO B E,�SS SG A XISTING 2000 M C EgD0.M H�u5E GAL S.T.E.P. TANK D FCO yam, SCALE: 1' = 50' A—C= 65.5' 100.8 100,8 ,� BOUNDARY: DRAWN: vBG B—C= 65,7' ASBUILT: DATE 7/17/01 DWG. FILE: GRID: s. S4 A—D= 67.8' N t° B -D= 70.2' _ �� 02.9/103,58 0� 102,87/102,83 al A—E= 85,7' FINAL GRADE B—E= 82.2 0 4 FILTER MRRIC 1NSULN110N VARIES A -F=101,8' AJS.T,E.P. 000 GAL Rim °j- B—F=120,5' N 10160 101,6TANK SEWER ROCK B -G=124.4' 100,60/100,60 100.60/100.60 ;4111;`` ,/ OF <Q �, / * : 9 TH * , ..... ... ...• ....... r /KE DUF S ;� CE -7116 �4 / rs �'Crti��''' � ..,._........... ' SSIdW 54' PREPARED FOR: JIM MCLIN 14900 LONGBOW DR. ANCHORAGE, AK 99516-4142 (907> 345-2217 FIELD BOOKS COMPUTED: BOUNDARY: DRAWN: vBG srAKwc a+eacEO: KMD ASBUILT: DATE 7/17/01 DWG. FILE: GRID: 3136 ACAD FILE: JOB No: 02026.dwg 02026 SCALE: NTS 9L6 mN LL_,Jl M) ENGINEERING 20441 PTARMIGAN BLVD. EAGLE RIVER, AK 99577-8736 6111 11 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Permit Number: SWO10274 Legal Description: TIMBERLUX #3 BLK F LT 2 Design Engineer: 0012 AK Environmental Control Services Owner Name: James McLin Owner Address: 14900 Longbow Dr. Anchorage , AK 99516-4142 Date Issued: Jul 24, 2002 Expiration Date: Jul 24, 2003 Parcel ID: 018-271-87 Site Address: 014900 LONGBOW DR Lot Size: 59242 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: ✓J Disposal Field ❑✓ Septic Tank [] Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special provisions. THE MAXIMUM DEPTH OF THE PROPOSED ABSORPTION BED SHALL BE ZERO (0) FEET FROM ORIGINAL GRADE. Received Date: /% - 2 Y_ 0 02 Issued By: /T-A4_� Date: -?/Z/oz, Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. fO I d -' 1 8} Permit Number SW Property owner(s) jy#mfs T Day phone 2-qz-- 3C09 Mailing address (1) j y loo L v/v� Mailing address Zip Code 755/(o Legal description (Lot, Block & Sub'd.) Loi- Z _9L.o4,K F 7—, —1 ea L�). * ? Legal description (Section, Township & Range) Lot Size 'fl I ZyZ Acres/Sq.Ft. THIS APPLICATION IS FOR: Number of Bedrooms Sewer Only Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: IOU Waiver Fees: Date of Payment: Date of Payment: Receipt Number: QZ_?(1d U1. OZ-?(1Receipt Number: (Rev. 12100) 1KN D ENGINEERING, INC. 20441 PTARMIGAN BLVD. EAGLE RIVER. AK 99577-8736 696-6111/FAX (907) 696-8111 May 10, 2002 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Septic Upgrade Modification - SW010274 — Timberlux #3 Lot 2, Block F Gentlemen: On July 30, 2001, you issued a permit for a septic upgrade of the above subject property. We propose to modify the original design from a non -pressurized bed to a pressurized system. The hole -spacing design of the pressurized distribution system is as follows: 1. RESIDUAL HEAD = 5' 2. HOLE SIZE = 3/16" =1.00 GAL. PER HOLE @ 30 PSI 3. 30 GALS (PUMP DELIVERY)/1.00 GALS./HOLE = 30 HOLES 4. 188 LF LATERAL / 30 HOLES = 6.27SPACING PER HOLE 5. ALL HOLES SHALL HAVE CAPS INSTALLED PER MANUFACTURES SPECS. 6. HOLES AT END OF LATERAL SHALL BE CONST. W/O CAPS AND PLACED DOWN. 7. CONTRACTOR SHALL USE 11/4" PVC FROM TANK TO FIELD AND IN FIELD. Groundwater elevations will be re -verified at time of construction. All other items on the original permitted design will remain the same. If you have any questions, please contact me at 696-6111/FAX 696-8111. Respectfully submitted, MID Engineering, Inc. eennethM. Duffus, P.E. James McLin 14900 Longbow Drive Anchorage, AK 99516 May 9, 2002 Municipality of Anchorage Development Services Department On -Site Water & Wastewater Program P.O. Box 196650 Anchorage, AK 99519-6650 Subject: Owner Installation — SWO10274 - Timberlux #3 Block F, Lot 2 Gentlemen: I, Jim McLin, will be performing my own excavation and installation of the above subject permitted septic design at my single-family residence. Per MOA requirements, a MOA approved engineer--KND Engineering, Inc, will inspect the installation. I have extensive excavation experience (septic, water, sewer, etc...). If you have any concerns or questions, please contact me at (907) 242-3009. Respectfully, OL G� Jim McLin June 10, 2002 1�Iumcipaity of Anchorage George P. Wuerch, Mayor Building Safety Division P.O. Box 196650 • 4700 S. Bragaw Street Anchorage, Alaska 99519-6650 • (907) 343-8301 http://u��a�. ci. anchora�c.alc.us James McLin 14900 Longbow Dr. Anchorage AK 99516-4142 Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW010274 Legal] Timberlux #3 ,Block F Lot 2 = Dear James McLin: An On -Site Water/Wastewater Permit, number S W010274, issued by this office for a single-family system, will expire on July 30, 2002. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit for a second year may be issued for a fee of $100.00 if the renewal application is received on or before the expiration date of the original permit. When applying for a new permit, the fees are: $400.00 for a wastewater pernut and $150.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincer , Jim ross, P.E. Manager On -Site Water and Wastewater Program Enc: Copy of permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ONSITE WASTEWATER DISPOSAL SYSTEM PERMIT Renewal Permit Number: SWO10274 Legal Description: TIMBERLUX #3 BLK F LT 2 Design Engineer: 0012 AK Environmental Control Services Owner Name: James McLin Owner Address: 14900 Longbow Dr. Anchorage, AK 99516-4142 Date Issued: Jul 30, 2001 Expiration Date: Jul 30, 2002 Parcel ID: 018-271-87 Site Address: 014900 LONGBOW DR Lot Size: 59242 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [✓] Disposal Field ! ✓/, Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5 The following special provisions. THE MAXIMUM DEPTH OF THE PROPOSED ABSORPTION BED SHALL BE ZERO (0) FEET FROM ORIGINAL GRADE. -_/l3 /02 RPP (NF w F_ �v(, /.GEE�p> 15 MpIC/N 6, P-40 PRESSu re 5 t F, * F14LCA669 LF77-F v4TF, O 5-110107- Received -110102 Received By: Issued By: Date: 7 O f Date: 7- 30 —0/ Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING 5 trvo /0 174 Parcel 1. D. n / 0 / — 9 17 Permit Number SW 600 2 (c5 Property owner(s) -_ r9 Md 57 %— 1415,411c/ Day phone a #,4 - Mailing address (1) / y 9 00 f o c�cJ Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) %�'�de�e lig t° _3 Legal description (Section, Township & Range) Lot Size %Acres/Sq.Ft. Number of Bedrooms L% THIS APPLICATION IS FOR: Sewer Only ® Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. G of property owner or authorized agent) Permit Fees: Date of Payment: J Receipt Number: (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: 6/8/2001 Municipality of Anchorage George P. ZVuerch, Mayor Building Safety Division P.O. Box 196650 • 4700 S. Bragaw Street Anchorage, Alaska 99519-6650 • (907) 343-8301 http://kk,Nklc.ci.ancliorage.ak.us James McLin 14900 Longbow Dr. Anchorage AK 99516-4142 Subject: On -Site Water and/or Wastewater Permit. Permit Number: SW000265 Parcel ID: #018-271-87 Dear James: Department of Public Works An On -Site Water/Wastewater Permit, number SW000265, issued by this office for a single-family system, will expire on July 28, 2001. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as -built inspection report must be sent to this office for review, approval and documentation. This as -built inspection report must be signed by the licensed Professional Engineer who inspected the installation of the system. As -built inspection reports are required to be submitted within 30 days of the completion of the system. If no system was installed under this permit, and you are still planning to install a well or wastewater disposal system, a new permit must be obtained from this office. A new permit may be issued free of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit. When applying for a new permit, the fees are: $320.00 for a wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-7904. Sincerel , 6&V Jam s Cross, PE Manager On -Site Water and Wastewater Program enc: Copy of permit MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On -Site Services Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Jul 28, 2000 Expiration Date: Jul 28, 2001 Permit Number: SW000265 Parcel ID: 018-271-87 Legal Description: TIMBERLUX #3 BLK F LT 2 Design Engineer: 0012 AK Environmental Control Services Site Address: 014900 LONGBOW DR Owner Name: James McLin Lot Size: 59242 SQ. FT. Owner Address: 14900 Longbow Dr. Total Bedrooms: 4 Permit Bedrooms: 4 Anchorage , AK 99516-4142 This permit is for the construction of: Disposal Field 7 Septic Tank Holding Tank ❑ Privy Private Well F-1 Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: el -31 -cd Date: 7-2 P "Ok5l Municipality of Anchorage (�4t):�) Department of Health and Human Services Tom Fink, 825 "L" Street Mayor P.O. Box 196650 Anchorage, Alaska 99519-6650 January 10, 1991 James Mc Lin 14900 Longbow Anchorage, Alaska 99516 Subject: Lot 2 Block F Timberlux Subdivision #3 Permit #900024, PID #018-271-87 The subject permit, issued by this office for a single family well and/or on-site wastewater system has expired as of December 31, 1990. A new permit must be obtained from this office for a well and/or on-site wastewater system not installed by the expiration date. If you have drilled the well, a well log needs to be sent to this office for documentation of the installation and to close the permit. If a private engineer inspected the installation of the on-site wastewater system, the original as -built inspection report (three-part form) must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $90.00 for an on-site wastewater permit; $50.00 for a well permit; $140.00 for a combined on-site wastewater and well permit. If you have any questions, Siiceely, Jomith, E. Prm Manager On-site Services JW/ ljm:200 enc: Copy of Permit please call this office at 343-4744. "Kids Are Our Future" MUN1L1PALl[Y UF ANLHOHAG£ 1eInartment oi 1--1ea1th & Human Servzces 82"D L Street, Anchorage, Alaska 99501 343-4720 ON -- SITE SEWER PERMIT 9� �� � Permit Number: 00024 Upgrade ���'��/L�����'� Date 1ssued: O1/30/90 Engineer Designed �Jwner Name: JAMEG MCLIN Owner Address: 14900 LONGBOW ANCHORAGE� AK 99516 Day Phone: 3-15�2�17 Parcel Id: 018�271�87 Lot Legal: Subdivision: TIMBERLUX #3 Lcit. : 2 Block: F Section: 34 Township: 12N Range: 3W Lot Size 59242 (sq,(t, or acres) Max Bedrooms: This Permit: 5 Total Capacity: 5 SEPTIC TANK: Minimum total septic tank capacity" 1�500 gallons" Each se�tic tanis must have at least 2 compartments" Depth to tpp of septic tank(s) ( 4,O �eet requiWs insulation over tank (so) PERMIT �XPIRES DECEMBER 31, 1990" VERIFY INTEGRITY OF EXISTING 1250 SEPTIC TANK, SECOND 1250 TANK WITH EFFLUENT PUMP 1`0 BE INSTALLED IN SERIES" TANKS MAY BE USED WITHOUT PUMP FOR TEMPORARY HOLDING TANKS PROVIDED ALARM IS INSTALLED IN DWELLING. FINAL SYSTEM INSTALLATION MUST BE COMPLETED BY JUNE 15v 1990" I CERTIFY THAT: 1, I am familiar wJ'th the requirements f rir on-site sewers and N as set forth by the Muricipality of ADchorage (MOA) and the State of Alaska^ 2, I will install the system in accordance with al1 MOA codes and regulations, and in compliance with the design criteria this permit. 3, I will adhere to all MOA and State of Alaska requirements Roo, the set back disit aqces [rom any existing wellsiewater disposaI system or public sewerage system on this or any adjacent or nearby Int. it I understand that this permit is valid for at maximum of 5 bedrooms, 1 also understand that the capacity of the Itotal system is 5 be�Pooms and any enlargement wil1 1-e11uire an additional permit" Signed: DATE: .... ..... ��-_~��_~~�~, _~�__~~_.~-�_-- (Owner> JAMES 11 IN < u�~ lssued By: DATE: ALASKA ENVIRONMENTAL CONTROL SERVICES, INC. 1200 West 33rd Avenue, Suite B ANCHORAGE, ALASKA 99503 (907) 561-5040 JOB L %" / /rH Jf W �✓ Y S�� SHEET NO. OF CALCULATED BY DATE CHECKED BY DATE SCALE PRoowrml 1n , Gm , Mm 01471. ALASKA ENVIRONMENTAL 02 f" !ter S✓ll 3 . , CONTROL SERVICES, INC. JCB 1200 West 33rd Avenue, Suite B SHEET NO. OF ANCHORAGE, ALASKA 99503 CALCULATED BY DATE (907) 561-5040 CHECKED BY DATE SCALE "— �O'�i Y /= YP✓ PRO=fiN ®1a kft #m 0I47L 3 TO c MA' T L , z AV vi I h7 ! 1 (p 40$L • _% 4• _ � 5CP be z�r - �� T oca eyt y�, a o� 3 �N ! Q crura B� 3 6f� . -hof 3 zorJE� • .R= • 0 �. Sed FBF+++ - or w '�� - �e• a ••• • •• ••':,... : _*•`., c `••ss• e• ••• •• e • ••.� _ l X94 \ / . Oo ,fy• • LEROY C. REID, : + 'cA CE -2251 ��J, ••• `*rr -:N.�•�'�•E ,lo.cb� eek91•.....•`��4;� :ESM T. iAw,essio� > �,? R , TYP ALL Cc PARS ©H IY Y SCALE. .I" =50' PLOT 'PLAN' GRID:.:` Sta& DRAWN Cu. PLG CHECKED HY: SL.. ERS. INC . - 7125 OLD SEWAgO�NWY.'}.. '.ANCHORAGE, ALAS"'A 88504° , I HEREBY .CER1IFYsTHAT.I''HAVE SURVEYED THE 'FOLLOWING DESCRIBED PA01?EATY, LOT—E.; :"BLK F. 'TIMZERL.UX:SUM;:A p 3ANCHORAGE-RECORDINGDISTRICT. AK. � - ANO'THAT THE IMPROVEMENTS SITUATED:THEREON-ARE WITHIN THE PROPERTY LINES t AND OONOT ENCROACW.ON THE PROPERTY.LYING.ADJACENT-THERETO, THAT NO 1 �+ IMPROVEMENTS. ON; PROPERTY l' YING AOJACENT.'tHEAETO ENCROACH ON THE PREMISES Iy^!�'�.� i IN QUESTIONdKD THAT THERE -ARE NO:ROADWAY.S.TRANSMISSION LINES ,OR OTHER VISIBLE -EASEMENTS ON SAID PROPER Ty EXCEPT AS'INOICATED HEREON. t 04*4 . ..•:•S LY' 'DATED' THIS T,. DAY'. OF or DAY' ANCHORAGE. ALASKA . �. •• .. ' .. -IT IS THE RESPONSIBILITY OF THE bWNER::OR BUILDER, PRIOR TO CONSTRUCTION. 31 • '.• ,3167; r TO VERIFY PROPOSED BUILDING GRADE -RELATIVE TO FINISH GRADE, AND UTILITY ` e •••••NM• - `�; Y CONNECTIONS AND TO. DETERMINE THE•EXISTENCE OF ANY EASEMENTS. COVENANTS OR RESTRICTIONS WHICH OONOT'APPEAR ON T{{E RECORDED SUBDIVISION PLAT. �\ �►� + JI A `C ALASKA RUIR011111C11TAL C011T110L SERUM, Inc. o Enqineerinq & Enuironmental Studies SPECIFICATIONS FOR BED WASTEWATER TREATMENT SYSTEM LEGAL DESCRIPTION: LOT 2, BLOCK F, TIMBERLUX SUBDIVISION -#-7 1.4 GENERAL 1.1 The Drawings, sheets 1 through 4, shall be part of this specification. 1.2 All materials and workmanship shall meet the requirements of the Municipality of Anchorage, Department of Health & Human Services (DHHS), the conditions of the permit, and all applicable rules and regulations currently in effect. 1.3 All excavations and depths are advisory, and are to be verified or modified in the field by the Engineer or inspecting agency. 1.4 It is the responsibility of the property owner or installer to adhere to approved design for the installation, to maintain the specified separation distances and to have the appropriate inspections. 1.5 It is the responsibility of the property owner or installer to report to the engineer any observed conditions which would put the system in violation of state or Municipal regulations. 1.6 If the installation is not inspected by an AECS engineer, AECS will not be responsible for the installed system. An engineer at AECS should be consulted prior to construction, to determine the number of inspections that will be required and to explain what these inspections will involve. 2.0 SEPTIC TANK 2.1 If there is an existing septic tank it may be used if it meets the capacity requirement for the residence. The structural integrity of the tank must be verified. 2.2 The septic tank shall be a UPC -approved two-compartment tank, constructed of 12 gauge steel with bitumastic coating and set level on undisturbed soil. If the tank is buried at a depth of 4 feet or less, it must be insulated with an overlying layer of 2 inch burial type polystyrene rigid board insulation. 14.12 WESL 3312b Avenue 0 Anchol2age, Alaska 99503 0 (907) 279-5553 2.3 The septic tank shall be a minimum of 5 feet from the house foundation, and a minimum of 5 feet from the absorption area. 2.4 The septic tank and bed shall be a minimum of 100 feet from any private well or body of water, 150 feet from Class "C" wells, and 200 feet from Class "A" or "B" wells, unless otherwise specified. Less than the required separation distance must have prior approval or waiver by DHHS or Alaska Department of Environmental Conservation (ADEC). 2.5 Piping shall be fitted with a mechanical watertight calder coupling on the cutlet and inlet of the septic tank. Piping shall be 4 inch solid PVC ASTM D-3034 or cast iron, sloped a minimum of 1/4 inch per lineal foot on the inlet side and 1/8 inch per foot on the outlet side. If the piping is buried at a depth of 4 feet or less, it must be insulated with an overlying layer of 2 inch burial type polystyrene rigid board insulation. 2.6 Cleanouts shall be installed as designated and capped with air -tight rain caps (Jim Caps or equivalent), and extend a minimum of 1 foot above ground level. 2.7 If a lift station is required it shall be a combination lift station septic tank per Anchorage Tank and Welding, Inc. design. Specifications and design drawings are on file with the municipality and the engineer. 3.0 SEEPAGE BED 3.1 The gravel for the bed shall be 0.5 to 2.5 inch, screened rock with less than 3 percent passing the No. 200 sieve. All substitutes must have prior DHHS approval. 3.2 The bottom of the excavation shall be level and raked with the backhoe blade to ensure that the bottom has not been compacted during excavation. 3.3 Sand, for leveling, shall have a size distribution which meets the requirements of MOA code 15.65.077. 3.4 The distribution pipe shall be perforated 4 inch rigid PVC with a minimum crush strength of 1500 pounds and shall meet the approval of DHHS for use as drainfield pipe. All pipes shall be laid level, and spaced according to the drawings. 3.5 Monitor standpipes shall be placed as shown in the drawings. They shall be 4 inch rigid PVC ASTM D-3034, or cast iron. The section shown with holes may be either drilled 0.5 inch holes on 6 inch centers on opposing sides of the pipe, or a section of regular perforated sewer pipe may be clamped to the solid section with a no -hub coupling or solvent joint. The perforated section of the monitor tube shall be located in gravel only. The portion of pipe above the sewer rock shall be solid. A rubber raincap (Jim Cap or equivalent) shall be placed over the top of the pipe. 3.6 Filter fabric is required. 3.7 The side slope of the mound shall be slope 1 foot vertical to 3 feet horizontal. 3.8 The bed shall be planted with a white clover and red fescue mix, or with Kentucky bluegrass. 4.0 INSPECTIONS 4.1 This bed will require a minimum of three inspections. The first inspection will be of the open excavation, to assure that the system is installed in the proper soil strata, correct depth and meet minimum specified design parameters. 4.2 The second inspection will be after placement of gravel, monitor standpipes, and distribution pipe, to verify proper installation and position of pipes prior to backfill. 4.3 The third inspection will be after final backfill grading and seeding to ensure that adequate soil cover has been provided over the bed. 4.4 The inspection of the septic tank or lift station installation can be incorporated with any one of the above listed inspections. 4.5 The lift station will require either an MOA electrical inspection or certification by a licensed electrician depending on whether the building code applies to this part of the city. '�,►'►a : •F e Municipality of Anchorage .;:; ... .•...• %;;. DEPARTMENT OF HEALTH & HUMAN SERVICES E .•.••• . •.... 825 "L" Street, Anchorage, Alaska 99502-0650 ..... 0� C REID, l SOILS LOG — PERCOLATION TEST �� •. CE -2251 PERFORMED FOR: /%C DATE PERFORMED:�� LEGAL DESCRIPTION: ZBF Tim bCr�u?r ?Township, Range, Section:?/ <-.7t-0:5 3'y SLOPE SITE PLAN 1 2 3 - I nwer 4- `' 5 6 ? i /-/j 6re'4-1 �4 ) lJ�i c/ern Sa.+cl 7 8 w / 10 WAS GROUND WATER ENCOUNTERED? S• 11 Ty/- � IF YES, AT WHAT 1L� O 12 DEPTH? T1�L — P E gepih to Water After ry/-16 13 Monitoring? >H'A^`1/gate: �Z a 14 15 16 17 18 19 ®®Gross me ... 20 IL_ JI PERCOLATION RATE '�Z (minutes/inch) PERC HOLE DIAMETER 1 / TEST RUN BETWEEN Z FT AND Z, S' FT COMMENTS �e tAM A7e.+ry bP-0 . 2? 5 4 4s.1 GJ 102EL7 2& e - PERFORMED BY: CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: / LZ/9/ S 4 72-008 (Rev. 4/85) 72-013 (Rev. 3/781 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street - Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT NAME PHONE EW James T. 1'I G Lin � �7j � 129'1 ❑ UPGRADE MAILING ADDRESS 377_1 Clie C.Kma+,*- T)s^ive. LEGAL DESCRIPTION 7irhbe,A,x *,3 Blocx Lo -t 2— LOCATION LOCATION - NO. OF BEDROfIIOMS DISTANCE TO: Well rID* irf Absorption area /Q Dwelling A14- but _;` PERMIT NO. U Y w* Manufacturer /+YCC.r" Material No. of compartments rn Liq. capacity in gallons IF HOMENIADE: Inside length Width Liquid depth iz 5-0 DISTANCE TO: Well Dwelling PERMIT NO. Jaz _ < Manufacturer Material Liquid capacity in gallons D w= DISTANCE TO: Well nor �'�) Foundation ?)of i7 Nearest lot lineS �. w- � ZS �j�[rl/,, PERMIT NO.n �� J LL Z No. of lines Length of each !ine Total length of lines Trench width Distance betty jen lines Fzw JRZ 260 inches QF Top the finish Material beneath tile Total effective absorption area of to grade Wiz, d D8 p inches Length Width Depth PERMIT NO. w Q F Type of crib Crib diameter Crib depth Total effective absorption area wa Lu w Well Building foundation Nearest lot line DISTANCE TO: _y Class Depth Driller Distance to lot line PERMIT NO. J LU DISTANCE TO: Building foundation Sewer line Septic tank Absorption area(s) OTHER L nc� a PIPE MATERIALS pvL cl SOIL TEST RATING ISO t7l/w"'N z INSTALLER McL.n Sc i REMARKS 3 < ah M P i I &L-im nil' 2X•t r'z- 2' i �Eafric+l 11 Sitoi; 3 6 .6 6 3 io 6e Sam . f alto $aid Ise ivo'jf &- mco� \A $ ' abflve C aired- `TOro rG 1p 'n APPROVED DATE LEGAL —61 - �1QLl� F L©T i ?'r`nrbvl�K # 3 3 72-013 (Rev. 3/781 MUNICIPALITY OF ANCHORAGE Departmentf Health and'Environmenta? ?ro.tection, 825 _ %Street, Anchorage., AK. �.J501 264-4720 # c7 -HANDWRITTEN' , # �a(J S's3Z� HANDWRITTEN' PERMIT Permit ON-SITE' .SEWER PERNtI T rle Applicant: J/�ilf�$ < 11V Mailing Address: Location: Phone ; Number: 3z,-3- /,� S Legal .Descripts.on: _ �T,2 slf- figs "X#3 Lot Size: 45 ?062a Type of Soil Absorption.; System Is: Trench. Drainfield: Seepage ..Bed: 12L_ Holding Tank Maximum:.Number of _Bedrooms: _, Soil Rating (sq.ft/br)__ISO The.Required :Sizeof_the-Soil_ Absorption System Is: DEPTH . LENGTH.- 1.2 GRAVEL DEPTH. G WIDTH the length .dimension is. the 'length (in'- feet) of the `trench or dra:infield. The ;depth of a :trench -or,,-pit is the distance between the surface of the ground and the bottom of -the excavation (in .feet) There is no--set :width for trenches The gravel 'depth is the minimum depth of gravel between the outfall pipe ands, the bottom of the excavation (in 'feet) # REQUIRED'S.EPTIC(HOLD ING) TANK SIZE_ GALLONS # Permit applicant has the:responsiblity to inform this department during the installation insp.ections:.of any wells adjacent to-.this property and the number of residences that the well will serve. TWO(2) INSPECTIONS ARE REQUIRED #, Backfilling of any system without final inspection-and approval by this departmen will, be.-subject to prosecution. Minimum distance between a well -and any on-site.-sewage ;disposal system is, 100 lee for a private+well or .150 to 2b0 feet:from .a public well depending upon the type of, public.='mell. Minimum distance from a private well to a private sewer line is 25 feet and to .a community sewer line'".is`75 feet. 'Well-logs are required and must be returned to.this department within.30 days of the well completion Other requirements may apply. Specifications and::con struction diagrams are available. to insure:proper installation-. # PERMIT EXPIRES DECEMBER 31, .1 9 u 2 # # I.,.certify that: {1) I :am':fam liar with -the requiremen-ts for-on-site,sewers .and wells as set`:forth"by the Municipality of Anchorage. (2) I'.will :install the system. inaccordance with ;codes. (3)' I, understand 'that the on-site sewer system may r qu re.:enlargement if the residence is.remodeled to include more that ::edro eb . Sign: Issued Applicant Z.' 7o & lxr57� Date: �4 �U //Ys�c7W 7�e 19ECS -y- SWP/024(.1/81) iNS c/o :�: .,, WROICIPAU Y 0-F-ANCHOAA ft ' rte"-ECTIPERCOLATION � DEPARTlV,T OF HEALTH AND ENVIRONMENTAL P ON TEST Gia L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERFORMED FOR: DATE PERFORMED: f 7 LEGAL DESCRIPTION: r', ' v 72.008 (6/79) i L�{,,�:u,.. .F:3M1s kc:N,seuas_ai +f3 .. ..._.... .. �. �.. . 'r - ' 1210 Ni. 251H, AVONUE MCHORAGE, AK. 99501 Supplemental Soils Information. Subdivision 'T) ryl 49r Lu 54 47�5 Block c;2— LOT LOT LOT LOT TH 2— TH TH TH pE PTH DEPTH DEPTH] DEPTH (FEET) (FEET) (FEET) (FEET) 2 2 2 2 3 3 3 3 4 4 4 4 5 1 ;. G.., 6r4uct�j 5 5 5 �ovldQ�S ) 6 / & 6- 7 7 7 7 7- 8 8 8 8 yr 9 g 9 9 10 10 10 10 11 11 11 11 12 12 12 12 13 13 13 13- 14- 14 14 14- 15- 15 15 -7 15 16 16 16 16 17 17 17 17 18 18 '18 18 19 19 19 19 a 20 20- 20 20 i P:.J:,1, 0-650 Al'%K',-iGRAGE, ALASKA 99502-0650 x A -411 11r DEPARTiVI L%N .`. CA. ' ',ryD NTAL. fa t i 7CTION <Permit #: 820911 January 31, 1983 TO: Permit Applicant Subject: Lot 2 Block F Timberlux Subdivision #1 A permit issued by this department for an individual well and/or on-site sewer system has expired as of December 31, 1982. Permits are issued on a calendar year basis, as stated on the permit, by authority of Municipal Ordinance. If you have drilled the well, a well log needs to be sent to this department for documentation of the installation date and to close the permit. If a private engineer inspected the installation of the on-site sewer system, please have them send us the as-builts for our files and documentation. If there are any further questions, please call this office at 264-4720. Sincerely �� Robert C. Pratt, R.S. Acting Program Manager Sewer and Water Program RCP/ljw enc; Copy of Permit SWP/057 ..... .r �. .....n-- .. �n — "�n,��v..�(eF.,-SYN4$/�.u+: 4✓'..w,.y4�fJLn, , Mvim. f4 KME ' :i.d7�FjAws T TJS./R�� LN.l is �-lili'f i'!."..3It .. .rte � �a � aye y+� ¢ +gyp. �i�y.��y ...�. 1C7L.. tits ar 7 E RXl 13 LOT Stze J97a'99 y �' 7"6 �. $964:1 riumm DISTA'�X QG� A WELL AM � iii;'J �T�TdGi� 1. r Apyf�'.RIVATE M iii Thi T � R F IC .�. �iit �. Tim � O MOLIC - 'i TI EAt titS'1`AMM MM A MWATE MFLL TO 8 PRIME SEWER LIM 15 "25 FM To a CamMFTY 'SEWER LINE IS 75 ' FEE L REWIRED ANiD.MJST BE i El°UMED TO THE l' T MUM$ 39 THE MeLL COWLertaK r Y. IFICRTIOM hYsTtr ST TIC"t DI AJORFM AM, �148WLREPENTS M51H�+y i rNSUR ...,mow' ' ` ,IilRll.aC ..2TTO yICK ^�. gRT Ry THRr i, I_ FRrLIAR WITH THE RE'ilUMDEHT'S FM ON-SM � � ice# 05 SMt mo ? FI➢BcY� T1li�isy�il:�9iyt�ICIJIF KTY QFF XNOR•yML . P yl�� per �g� �r�yyv IMTALL +LL t HC a'f�wia to A00OR� i4t i i'2..._ YF E Oxmm: ... s. . H M U N I CZ: I Foo I V F= t� N 17-: "*mqz,- 1=4 C3- EF DEPARTMENT L HEALTH AND ENVIRONMENTAL i..JTECTION 825 L` STREET, ANCHORAGE, AK. 99501 264-4720 L4F=L-1 F=u ]—= FZ rl I -T PERMIT NO. 4 820911 ) APPLICANT JAMES T MCLIN 3721 CHECKMATE DR APT A 99504 333-1294 LOCATION LEGAL L2 BF TIMBERLUX S/D #3 LOT SIZE 999999 SQUARE FEET MINIMUM DISTANCE BETWEEN A WELL AND ANY ON-SITE SEWAGE DISPOSAL SYSTEM IS 100 FEET FOR A PRIVATE WELL OR 150 TO 200 FEET FROM A PUBLIC WELL DEPENDING UPON THE TYPE OF PUBLIC WELL. MINIMUM DISTANCE FROM A PRIVATE WELL TO A PRIVATE SEWER LINE IS 25 FEET AND TO A COMMUNITY SEWER LINE IS 75 FEET. WELL LOGS ARE REQUIRED AND MUST BE RETURNED TO THE DEPARTMENT WITHIN 30 DAYS OF THE WELL COMPLETION. OTHER REQUIREMENTS MAY APPLY. SPECIFICATIONS AND CONSTRUCTION DIAGRAMS ARE AVAILABLE TO INSURE PROPER INSTALLATION. F="F= FRM I -r FE X Fz* I Fe F=:E; L.A Fz'r,� F= M E� a F;;.* _-3 A _- :jL 1=4:0 � I CERTIFY THAT 1: 1 AM FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND WELLS AS SET FORTH BY THE MUNICIPALITY OF ANCHORAGE. 2: 1 WILL INSTALL THE SYSTEM IN ACCORDANCE WITH THE CODES. SIGNED: -------------------------- APPLICANT TAMES T MCLIN ISSUED V4. 0 e LOCATION OF WELL (Please complete either to, Ib or Ic.) WATER WELL RECORD STATE OF ALASKA DEPARTMENT OF NATURAL RESOURES Division of Geological & Geophysical Surveys Drilling Permit No. A.D.L. No. Tall Borough Subdivision Lot Block Ib. V4gtrs. Section No. Township No Range E El Meridian Ff_of— s❑ WO I I aZ —a Ic. DISTANCE AND DIRECTION FROM ROAD INTERSECTIONS 3. OWNER OF WELL: Jfm Address: 330't L.+OW t FA( fir.... Street"l Address and Area of Well Location. k fL�C"k,..f A 2. WELL LOG Feet Below Surface,_ 4. WELL DEPTH: (final) 5. DATE OF COMPLETION ��. _ Aa - Material Material Type Top Bottom --`�=ft ,x !1I ,_.... _ s,. 6, 0 Cable tool E3Rotary E)Driven E] Dug . E] Auger C]Jetted C] Bored ❑ Other: t'2,e I V iANf;1 *k 6)4AVtJ R LY 4- f �RICy H 7. USE: ®"Oomestic F1 Public Supply ❑ Industry E] Irrigation a Recharge Commerical Well [3 Other: Q"?f,-7. Pri?%7MT Ci? E ;i A .b i'V, ""ALOV 62,AVE1 UWETest .LLT `,_ iA-417V ARMAVEL4 IWATPe f } 4 S. CASING: C] Threaded E] Welded diam. in. to ft. Depth Weight Ibe./ft. r diom, in. to 2 ft. Depth Stickup . ft. `' a r^ 8 �7 _ d:'} 6f �'F+ ef"c RII) . P%Nf. X18 #. /5-10 9. FINISH OF WELL: Type: Diameter• Slo1/Mesh Size: Length: Set between ft, and ft. Backfilling Gravel pack 10. STATIC WATER LEVEL: ft. Above or 0 Below land surface Dote Equipment used: - I I . PUMPING LEVEL below land surface and YIELD it. after _ hrs. pumping g.p. m. ft. after hrs. pumping g. p. on. 12.GROUTING Well Grouted: Yes Callo Material: E] Neat Cement Other: 13. PUMP: (if available) HP Length of Drop Pipe ft, capacity g.p.m. O Subm. M Jet (3 Centrifical 0 Other 14.REMARKS: +$'lf`?!76o' 8 �P'f�'` " � -. 19"wf4 16. WATER WELL CONTRACTORS CERTIFICATION: 15. Water Temperature 0 F C Thiswell was drille�dd under my jurisdiction and this report is true to the best of my knowledge and belief; Vidt N, IyApk i P f RegisteredBusiness Name Contract License Number #t A ddle ss: }'-l�, ` Y gi. I>. _. o by pp _ ,+ Signed t,f4o rr°...f, 7"/P, Jfr'R,.k°. Date: q, d Authorized Representative Form 02-WWR (11/81) Copy Distribution: WHITE-Stote DGGS, PINK -Driller, CANARY -Customer Time APPI-r"ANT FILLS" OUT UPPER HQ = ONLY . ?roperty Owner'� Jt�r,>} f 5 - --> i'�C/j%f"1= y" / Phone Date Date Mailing gess.: Zip Code Buyer YA- ZZ, Address Zip Code Lending Institution r, Phone �,r ... �. ^y 7e- ` / —%G-1;0 Address -y - ,,,._ �isir Zip Code'" -C3„ MUNICIPALITY OF ANCHORAGE Realty Co. & Agent Phone Address Zip Code RECEIVED Legal Description �, "e" r _. ( ) DISAPPROVED Street Location ( ) CONQITION�AL N,pPRO,VA!i Type of Residence BY: Ingle Family Soils Rating Date Sewer Installed ❑ Multiple Family No. of Bedrooms ❑ Other Well to Tank Septic Tank Size Water Supply -2�'Individual ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. ❑ Community For wells drilled prior to that date, give well depth (attach log if available). ❑ Public Utility Sewer Disposal ndividual Year Individual Installed: ❑ Public Utility When Connected to Public Utility: ❑ Holding Tank NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. Time Time Time Time ` ci)u Date Date Date Date l YA- ZZ, Inspector Inspector Inspector Inspector Field Notes: w MUNICIPALITY OF ANCHORAGE t DEPT. OF HEALTH & ENVIRONIv1cIVTAL PROTECTION APR 1 1 4063, RECEIVED ( APPROVED BEDROOMS 'CONDITIONS OF APPROVAL ( ) DISAPPROVED ( ) CONQITION�AL N,pPRO,VA!i DATE BY: Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received E- (3 Z--- Well to Tank Septic Tank Size 72023 (3182)