Loading...
HomeMy WebLinkAboutAUDUBON HILLS TR A2Audobon Hills Tract A- 2: #015-231-65 Municipality of Anchorage On -Site Water and Wastewater Section • (907) 343-7904 40*r ON-SITE WASTEWATER INSPECTION REPORT NOS` Permit Number: OSP191374 PID Number: 015-231-65 '2019 Dwelling: 0 Single Family (SF) ■❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New X Upgrade Name Todd &April Erickson ABSORPTION FIELD ❑ Deep Trench 0 Wide Trench ❑ Bed ❑ Mound Site Address 12101 Audubon Dr. Anchorage, AK 99503 ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 444-5577 4 1.2 GPD/SF JTotal 1.91 /1.86 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 1.41 /1.36 Ft. Gravel depth beneath pipe 0.5 Ft. Subdivision Block Lot Audubon Hills Tract 2A Fill added above original grade 1.39/1.74 Ft. Gravel length 2 @ 50 Ft. Township Range Section Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 5500 Ft2 2 >6 Ft. Well >100 ' > 1 00' N/A N/A >25' TANK I9 Septic ❑ S.T.E.P. ❑ Holding E:1 Other Manufacturer Greer Capacity 1,250 Gal. Surface Water >1 >1 00' N/A N/A Material Number of compartments Lot Line >5' >10' N/A N/A NA Plastic 2 Foundation >10' >1 0' . N/A N/A LIFT STATION Manufacturer Capacity Gal. Remarks Tank and trenches are insulated. Alarm location Electrical installed by PIPE MATERIAL House to tank D3034 Tank to D3034 drainfield Installer A+ Home Services Drainfield D3034 cO/MT D3034 Inspector J. Millette / J. Williams BENCH MARK (Assumed elevation) 100 ft Inspeection 10/16/19 15` 10/15/19 Location and description 2nd ction Nail located on corner fence post near ADU. aro 41h ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp OF '° ®� Conditional Approval: Date �.�P,°•••""" °°••:9S 49th ......° .°.. .. ...2T..'b.....� ..................................... .n....�.� ��n e MICHAEL E. ANDERSON �0®�sJ':° No. CE -4381 • `�® a°•.°° Septic System Approved �f1L'" Date �20�0 11/25/19 .°''�r� �� Note: this approval does not include well permit requirements. �Q�q�®®��� (Rev 05/02/18) // // // // // // // // // // // // // // // // // // // // 895890885 // // // // // 100500 FEET 1"=50' CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND PERMIT # OSP191374 PID # 015-231-65 AUDUBON HILLS, TRACT A-2 A B 2CO1 31.4 MH1 36.7 SV1 41.5 A B 2CO2 43.3 FD 44.3 MT1 50.5 CO1 49.0 30.9 35.4 36.8 37.9 55.0 53.5 11/25/19 1 BDRM A.D.U. COVERED STORAGE GREENHOUSE SHED WOOD FENCE 10' UTILITY EASEM E N T GRAVEL ROADTH1 NEW 1,250 GALLON SEPTIC TANK w/20" MANWAY 2-50' LONG X 5' WIDE X .5 EFFECTIVE DEPTH ABSORPTION TRENCHES EXISTING WELL CO2 MT3 CO4 CO1 CO3 MH SV 2CO1 PLAN AS-BUILT MT2 69.8 CO2 70.5 61.3 62.2 MT3 66.2 CO3 63.4 72.4 69.7 MT4 72.0 CO4 73.5 66.7 68.5 26.5 2CO2FD MT1 MT2 MT4 3 BDR M H O M E GARAGE PROFILE AS-BUILT (NO SCALE) 92.0 86.9 92.6 96.2 94.1 FINISH GRADE 50' DRAINFIELD ROCKMTFCO 2CO1250 GAL GREER TANK TH#1NO GROUNDWATER 8/9/19 90.8 91.3 COCO84.71 90.8 91.3 91.8 92.71 ORIGINAL GRADE PERMIT # OSP191374 PID # 015-231-65 AUDUBON HILLS, TRACT A-2 11/25/19MT91.0 FINISH GRADE 50' DRAINFIELD ROCKMT TH#1NO GROUNDWATER 8/9/19 87.4 87.9 COCO81.26 87.4 87.9 89.26 ORIGINAL GRADE MTMHSV2CO2" INSULATION 2" INSULATION 2" INSULATION WEST TRENCH EAST TRENCH C -u --i* mOq Z r -=y deck �ti 4�b m -D- ( J) M D 0 s 6 C-) ��mm D r o tri � � Orn =z i z 0 ITl � �. = o m�z0 _ 32 =Cn oma �p 7 O Z m I � � 00 M:* �=0 O D r- O= rn� � moo I 32.0—�- 0 rnXn0 000 = I �o� �� 0 zM .� N I 3 w '2\ 6 00 CA Z Co Cn w a-0 cn �-, -0 0- 0 Cp < � D a m�C�, M CD Cr CD�070 �,. CL C `Z c- xCD Z CD �oCD� ? a1< O CD M a �. � o � co o a v 0- � ^. (D %< . O o- -•i cn 7) C o o .0 3Z2. . c2. o a CD :' '" W a 3 .. v CD � CD D �o0M 0 0 CD o�oo � CD in��CD oa0 CL o (n CD � Cc: (n CD CD Cp�- rn O3 CD - C51), a O O -+• —� :3 m�� O — v� N � a v o o"'< c 8 r D cD CL z: CO:��Co - �, cn C: :3 Q. O Q. CCPD n 0 < O D CO'0.m o CD cD ° 3 rn o -0 o y O< a N 3 .2 Co CD [7 U) L rn CD co' o- `< 3: N a a C c co cn o ­ 0 o cn o � CD CDN n (0 rn c CD 0- =3 FD O n 7 cC � r- 0 w 00 0 deck 32.0 32.0 N 0 10' Utility Easement 0 0 0 CL 1-4 o Q 0 CO CD o D 8 o O n � 0 6 o 0 oa °08 deck .Cb 4 D 0 s 6 C-) C7 o --i dk v Q) D Q16C �0 8 N • �� I � � 00 D r- I 32.0—�- 0 w I 0 4.0 �� 4.0 0 39 28.0 N I 3 w '2\ CD N 00 CA N 0 O Cn I o I �C/) o�� 3 C) cD I o0 v G) v < CD CD N CO I m CA I o v Z w o CD r, OI Q 0 CD (n C + —1 D Cgyp I � 0 0- mI (nI CD � CD D �o0M 0 0 CD o�oo � CD in��CD oa0 CL o (n CD � Cc: (n CD CD Cp�- rn O3 CD - C51), a O O -+• —� :3 m�� O — v� N � a v o o"'< c 8 r D cD CL z: CO:��Co - �, cn C: :3 Q. O Q. CCPD n 0 < O D CO'0.m o CD cD ° 3 rn o -0 o y O< a N 3 .2 Co CD [7 U) L rn CD co' o- `< 3: N a a C c co cn o ­ 0 o cn o � CD CDN n (0 rn c CD 0- =3 FD O n 7 cC � r- 0 w 00 0 deck 32.0 32.0 N 0 10' Utility Easement 0 0 0 CL 1-4 o Q 0 CO CD o D 8 o O n � 0 6 o 0 oa °08 Gravel road S00002'00"E 133.42 I n I n" o C- I _ a-._ m m CD 3 D DCD = 0< CD CD15 0.0 cv �� o < o Oa0 a �m Cn v CD > > CD C CD �< D O v CD 0 3 pp Q CO w D 0 CD rn CD rn Cv ° m° Z o" C 0 oN CD S CD CD (n CD � (D r N N o CD CD �000�wo =off? -10 cn CD ;-• Q rr- a w C) 0 o 0 �� o °' �' Cn D— N D � � a � ,-.. -, CDS � cn Z i a Ti-na) LD.� � o �0 CD Cl- C:> < O a cnm vv _0 300 Cn �� Oon�-0 0 CD cD ° o-< �o CDo o Z � �S11 � CD _0 41bp •. �D 3-u3�c�cn ON�'� moo"'• cZD Po cD � a �5,(C O / Ln N rn �- • 0 / O Cn u CD= O O (D zy z _ �� 1/ 0 r •� / � .- r . • • • � (n N CD _a O C O COD / • • / O O cD O —. -p * CD • 0 CD AW CD CD M AMF U) � � (DD CD M '0, SGS • • • _ Q �' (n V r 0 Cn . Cn D m AV deck .Cb 4 D 0 s 6 C-) C7 o --i dk v Q) D Q16C �0 8 N • �� C7 00 28.1 W w � 0 4.0 �� 4.0 0 39 28.0 0 X36 '2\ N Cn 0 -, 3 cD v G) v < CD CD o 0- 0 Gravel road S00002'00"E 133.42 I n I n" o C- I _ a-._ m m CD 3 D DCD = 0< CD CD15 0.0 cv �� o < o Oa0 a �m Cn v CD > > CD C CD �< D O v CD 0 3 pp Q CO w D 0 CD rn CD rn Cv ° m° Z o" C 0 oN CD S CD CD (n CD � (D r N N o CD CD �000�wo =off? -10 cn CD ;-• Q rr- a w C) 0 o 0 �� o °' �' Cn D— N D � � a � ,-.. -, CDS � cn Z i a Ti-na) LD.� � o �0 CD Cl- C:> < O a cnm vv _0 300 Cn �� Oon�-0 0 CD cD ° o-< �o CDo o Z � �S11 � CD _0 41bp •. �D 3-u3�c�cn ON�'� moo"'• cZD Po cD � a �5,(C O / Ln N rn �- • 0 / O Cn u CD= O O (D zy z _ �� 1/ 0 r •� / � .- r . • • • � (n N CD _a O C O COD / • • / O O cD O —. -p * CD • 0 CD AW CD CD M AMF U) � � (DD CD M '0, SGS • • • _ Q �' (n V r 0 Cn . Cn D m AV MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 3434997 http:l/www.muni.org/onsite On -Site Wastewater Disposal System Permit Permit Number: OSP191374 Work Type: Septic Upgrade Tax Code Number: 01523165000 Site Legal Address: AUDUBON HILLS TR A2 G:2739 Site Mailing Address: 12101 AUDUBON DR, Anchorage Owner: ERICKSON APRIL L & TODD E Design Engineer: FORGE ENGINEERING This permit is for the construction of: 0 Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Effective Date: Expiration Date: 8/28/2019 8/27/2020 Lot Size in Sq Ft: 65611 Total Bedrooms:. 4 ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing .:lA,;i11.,/' �i itcLt:ZOO Date: Lqr Date: 0g / f�rk� MUMUF ° UTY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-231-65 Property owner(s) Mailing address _ Site address Todd and April Erickson Day phone 907-444-5577 12101 Audubon Drive Anchorage, AK 99503 Same Legal description (Sub'd., Block & Lot) Audubon Hills, Tract A2 Legal description (Township, Range & Section) Lot Size 65,611 Sq. Ft. Number of Bedrooms Four APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑x Initial ❑ Single Family (SF) ❑X (w/wo ADU) Septic Tank ❑X Upgrade pg � ❑ Duplex (D) Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: 95q 5 Date of Payment: 912-1 110 Receipt Number: 60 Llo J�) Permit No. ose I I 0-714 Permit App__- : :'-._'c Waiver Fees: Date of Payment: Receipt Number: Waiver No. PO BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 22, 2019 MOA Development Services Department On-Site Water & Wastewater Program 4700 Elmore Rd Anchorage, AK 99507 Subject: Audubon Hills, Tract A-2 – 12101 Audubon Drive Septic System Design and Permit Application Dear On-Site Services Engineer: The septic system on the subject lot has failed and must be replaced. We are submitting this design and permit application for the construction of a new septic system to serve the three-bedroom home and one-bedroom A.D.U. on the lot. The attached site plan identifies the location of the structures and the existing well along with the existing and proposed septic locations. No conflicts exist between the proposed system and any other well or septic system on this or adjacent lots. The ground surface on the lot slopes to the west. There are no slopes greater than 25% within 50 feet downslope of the proposed site. Topographic contours are shown on the site plan showing the grade and direction of flow. Storm water drainage will not impact this septic system. The new trenches will be constructed parallel to the slope as much as possible. Wells on this and adjacent lots are shown. The new system will be a minimum of 100’ from all wells and surface water, and more than 5’ away from the septic tank. Please refer to the attached test hole log and plan and profile sheets for the septic design. If this design is followed, there will be no adverse impacts to adjacent properties. Sincerely, Michael E. Anderson, PE 8-22-19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191374, Rebecca Carroll, 08/28/19 // // // // // // // // // // // // // // // // // // // //89589088510050 0 FEET 1"=50' NOTE: NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE PROPOSED SEPTIC SYSTEM ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS. CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE FD - FLOW DIVERTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE LEGEND MT AUDUBON HILLS, TRACT A-2 8/27/19 1 BDRM A.D.U. 2 STORY FRAME GARAGE COVERED STORAGE GREENHOUSE WIRE FENCE SHED WOOD FENCE 10' UTILITY EASEMENT GRAVEL ROADTH1DECOMMISSION EXISTING SEPTIC TANK PER MOA CODE. 1,250 GALLON SEPTIC TANK w/20" MANWAY 2-50' LONG X 5' WIDE X .5 EFFECTIVE DEPTH ABSORPTION TRENCHES EXISTING ABSORPTION BED. EXISTING WELL CO MT CO CO CO MHSV 2COFD FS 3 BDRM HOME FCO FCO Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191374, Rebecca Carroll, 08/28/19 AUDUBON HILLS, TRACT A-2 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW PERK RATE: 1-5 MIN/IN APPLICATION RATE: 1.2 GPD/SF 5' WIDE TRENCH SYSTEM 1,250-GAL SEPTIC TANK TYPICAL TRENCH SECTION (NO SCALE) 5' NOTES: 1. GRADE AREA OVER TRENCH TO DRAIN AWAY 2. PROVIDE 3' OF COVER OVER TRENCHES AND 4' OVER SEPTIC TANK, OR 2' WITH 2" OF INSULATION 3. CHECK GROUNDWATER AT TIME OF CONSTRUCTION. IF LEVEL IS HIGHER THAN PREVIOUSLY OBSERVED, CALL ENGINEER IMMEDIATELY BOTTOM OF TRENCH: 2.0' BELOW GRADE FLOW LINE ELEVATION: 1.5' BELOW GRADE TOP OF TRENCH: 2' ABOVE GRADE 600 GPD / 1.2 GPD/SF /5' WIDE / 1.0 RED. FACTOR = 100 LF TRENCH REQUIRED (100 LF SPECIFIED) 8/22/19 4" PERFORATED PVC (HOLES DOWN) 6" 6" 1.0' 2' DRAINFIELD ROCK GEOTEXTILE FABRIC 3 1 4" TOPSOIL & REVEGETATE Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191374, Rebecca Carroll, 08/28/19 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 1 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Tract A-2, Audubon Hills 7/3/19 J. Millette DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- 2.6 6 4 5 015-231-65 April Erickson 10:19/10:29 7/31 1 2 3 4 5 6 4/9 7 16 10:30/10:40 10:41/10:51 10:51/11:01 11:01/11:11 11:12/11:22 OG Professional Engineers Stamp: 8/22/19 10 No None 8/9/19 5 7 16 4/812 1610 412 16 4/715 1610 315 16 4/8 1 1610 4 1 16 4/8 3 1610 4 3 16 4/714 1610 314 16 4/713 1610 313 167 11:23/11:33 See Site Plan ML DENSE/IMPERMEABLE GM/GW GRAVEL w/SILT & SAND Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191374, Rebecca Carroll, 08/28/19 LEGAL DESCRIPTION: PERFORMED FOR: DATE: PARCEL ID#: SOILS LOG AND PERCOLATION TEST TECHNICIAN: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 DEPTH (feet) PROJECT No.: TEST HOLE 2 SLOPE SLOPE SITE PLAN DATE READING GROSS TIME (minutes) NET TIME (minutes) DEPTH to WATER NET DROP TEST HOLE PRESOAKED PRIOR TO TESTING: PERC. HOLE DIA. (INCHES)PERCOLATION RATE: (MIN/INCH) TEST RUN BETWEEN: FT. and FT. COMMENTS: (inches)(inches) Tract A-2, Audubon Hills 7/31/19 L. Tidwell DATE OF MONITORING: WAS GROUND WATER ENCOUNTERED? DEPTH OF WATER AFTER MONITORING: IF YES @ WHAT DEPTH?- 1.95 6 4 5 015-231-65 April Erickson 10:12/10:22 7/31 1 2 3 4 5 6 12/164 16 10:24/10:34 10:34/10:44 10:45/10:55 10:55/11:05 11:05/11:15 OG Professional Engineers Stamp: 8/27/19 10 No 4 4 16 12/161 1610 4 1 16 12/173 1610 5 3 16 10 12/172 1610 5 2 16 10 See Site Plan GM/GW GRAVEL w/SILT & SAND 12/173 16 12/172 16 5 2 16 5 3 16 PERCOLATION TEST ONLY. Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191374, Rebecca Carroll, 08/28/19 De. 28 :, 11:0,a Anchoi-age 'A'e 18, S -or D072430742 P DeVOOPMelit Services bepartrnent BuMing 5cfety bivision 4700 Et -,10-e Road Box 19 Or -Site Water 4 WCStewater Program twank soqic,; A ho nj ge, A K 019507 Ma Vc, f 7) 34---7904 Pump Installation Log WC-11rilf = Ia n -'Number: Date of Issue: Parcel 1dendfkation Nt,11.1bel,: 2 3 11 - (- 5 Aftertion: Te P11,117 0 tht DSD wi-,hin _O (if pur"J" DEPT. OF ENVIRONMENTAL CONSERVATION TONY KNOWLES, GOVERNOR ANCHORAGE/WESTERN PUBLIC SERVICE AREA OFFICE 555 CORDOVA STREET ANCHORAGE, ALASKA 99501 September 18, 1995 Mr. Jim Duggan 200 West 34th, #435 Anchorage, Alaska 99503 SUBJECT: (907) 269-7519 RECEIVED SEP 2 1 1995 IViUn~clpai~y o] ~nchorage Dept, Health & Human Services Lot A-2 Audubon/Subdivision, Anchorage, Alaska, Class C Public Water System and Wastewater Disposal System, ADEC Project Number 9621-VVW- 256-123, Review Dear Mr. Duggan: I have reviewed your September 13, 1995, submittal regarding the upgrade of your four bedroom single family home into a three bedroom Bed and Breakfast. Based on this review, I have the following comments: From the submitted information and my review of this office's files, it appears that the existing water system was approved as a Class C Public Water System by this Department on September 13, 1984. Based on this information and the fact that the demand on the existing water system will not be increased, it appears that the water system will be able to meet the demand without modifications. Therefore, the existing Class C Public Water System serving the three bedroom Bed and Breakfast and the one bedroom single family home located on the above-referenced property is approved for the concerns of this Department. The final Operation Certificate issued by the Department on September 13, 1984 is still valid. The existing four and two tenths (4.20) milligrams per liter (mg/I) of nitrate (as nitrogen) is above ambient levels for nitrate (.4 to .9 mg/I) normally found in groundwater in the State of Alaska. Although the nitrate level is above ambient conditions, it is below the maximum concentration level for nitrate (10 mg/I) set in the State Drinking Water Regulations, but the existing level does show degradation of the water quality of the aquifer that you are withdrawing water from for drinking. Due to the possibility of continued degradation of the aquifer's water quality and to ensure the public health will be protected, annual analytical results for nitrate (as nitrogen) and total coliform bacteria will need to be submitted to this Department. I recommend that the water samples be collected during February - March of each year. If nitrate levels remain over eight (8) mg/I for more than two consecutive Mr. Jim Duggan September 18, 1995 Page 2 samples, either engineering plans for the installation of a nitrate removal system or notification of some other solution will need to be submitted to this office. Due to the monitoring requirements of the operation approval, please ensure that the Public Water System Identification (PWSID) Number 218472 is placed on all analytical results submitted to this Department. The existing wastewater disposal system was tested on July 14, 1995, to determine if it will accept the waste flow from the one bedroom single family home and three bedroom Bed & Breakfast. On the day of the test, the existing wastewater disposal system was able to accept the minimum amount of water. Thus, the wastewater disposal system is acceptable. Thus, in accordance with the provisions of 18 AAC 72, Wastewater Disposal Regulations and the Department's guidelines, the wastewater disposal system serving the facility on Lot A-2 Audubon Subdivision is approved for operation. The enclosed "Approval of On-Site Residential Water and Sewer Systems" ..certificate constituting the final operation approval for the existing wastewater disposal s~/stem. These approvals do not imply the granting of additional authorizations, nor obligate any state, federal, or local regulatory body to grant required authorizations. Thank you for your coordination with this Department. If you have any questions, please do not hesitate to contact me. Sincerely, Keven K Kleweno, ~.1::. Environmental £ngineer KKK/pt Enclosure: As Stated CC: Lynn Johnston, ADEC/SCRO/EH/DW, w/o Enc. Jim Cross,P.E., MOAJDHHS, w/o Enc. MUNICIPALITY OF ANCHORAGE  DEPARTMENT OF HEALTH & ENVIRONMENTAL PRO ~ £CTION ENVIRONMENTAL ENGINEERING DIVISION ' 825 L Street- Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT "~*-~'I~"~NE I [] NEW ~l~ -- ~ ~'AI LING ADDRESS ~ ~ ~ LEGAL DESCRIPTION ~ NO. OF BEDROOMS ~OCATION Well ~ Absorption area Dwelling PERMIT NO. DISTANCE TO: ~ t ~' ~ ' ~ ~ Material . No. of c~mpartments ~ Manufacturer ~.~O~ ~" ~ Inside length Width Liquid depth Liq. capacity in gallons t ~O IF HOME.DE: . PERMITNO. Well Dwelling ~ ~ DISTANCE TO: ~ o z Material Liquid capacity in gallons O ~ ~ Manufacturer Foundation Nearest ~ot line PERMIT NO. Well Q DISTANCE TO: I~ 3 ~' ~ ~ ~ Trench width Dista ~ ~ Z No. of lines Length of each line Total length of lines n~e~etween lines -- ~ ~* Total effective absorption area  Top of tile to finish grade , Material beneath tile PERMIT NO. Length Width Depth ~ Total effective absorption area < ~ Type of crib Crib ~iameter Crib de~th m Well Building foundation Nearest lot line ~ DISTANCE TO: C~ass Depth Driller Distance to lot line PERMIT NO. ~ Absorption area(s) ~ Building foundation Sewer line Septic tank ~ DISTANCE TO: :- OTHER ~~ PiPE ~ATERIALS G~ t~ 8~~ o~0 ~/N~ SOIL TEST RATING ~E~.~s ~ ~ ........ .~.~?,a ~&~..' A ...~.-~ _ t ~ ~ ~. ~- .. , ................. , ........ - APPROVED ------ DATE LEGAL / 72-013 (Rev. 3/78) ' FLATTOP TECHNICAL SERVICES CIVIL & ENVIRONMENTAL ENGINEERING · ALTERNATIVE ENERGY DESIGN · TRANSPORTATION PLANNING THEODORE F. MOORE, P.E. PH: (907) 345-1355 September 5,, t9~4 STAR ROUTE, BOX 7380N ANCHORAGE, ALASKA 99516 Alaska Department of Environmental Conservation 437 E Street Anchorage, Alaska 99501 Attn. Jim Hayden l/ear ?Ir. Hayden: The enclosed information and plans re,:~ardinq the required upgrade of the waste disposal system serving Tract A-2 of :\udubon Hills Sub. in Anchorage, owned by James Du§gan, ~s submitted for your approval. I understand that your office made a deter~nin- ation that the house should be classified as a duplex, and that the existing crib/cesspool serving it's lower floor, but actually located on Lot 1 was the source of the effluent leaching out of the recently cut bank. To ascertain the appropriate corrective action, two test holes were dug on August 29 in the locations shown on the enclosed !q.O.A. soils log report form. and logs fron previous test holes on Lot 1 and Tract A-1 were examined. The soils in that vicinity shows great variation within very short distances. In test t~ole #2, the oortion of the G!.! layer where I con.~ucted a perc test proved to be unsatisfactory, however beneath it is a layer of clean sandy gravel (GW). Since the water table is at approximately lj ~eet, I propose that a bed type absorotion field be ~nstalled in this layer at a depth of 9 feet in accordance with standard M.O.A. specifications (copy attached). Ti~e bed will consist of a 6 inch thick ]aver of screened gravel (1/2"to 2. 1/2") under the absorption o~pe and extended to 2" above the p~pe. Using the corresponding so~l rating of 85 sq. ft./bedrooln for GV and 4 bedrooms, the necessary absorption area of 340 sq. ft. can be accomplished with 57 lineal feet of bed which is 6 feet wide. Due to space constraints, the best configuration appears to be a bed 1~ feet wide by 19 feet ]on.g with three 19 foot runs of perforated pipe spaced 6 feet apart. During construction some modification of this configuration may become necessary to conform to localized soil conditions. . __ ' ' t-- ~' -'~ ~ ~ ~,11 ~c~ ~ ~Y ,~ ~ ..... We wish to request a waiver o~ vne z3u ~o~t separation requirement between the well and the wastewater treatment works. A gas line along the property line separating Tracts A-1 and A-2 is 15 feet north of the test hole. Slopes and probable clay soil preclude a linear system parallel to the %as line. !t is possible that the entire absorption field can be accomodated outside the 150 foot radius, but the septic tank will almost surely have to be closer. There is not room for any replacement system outside the radius. We request a waiver of the seoaration criteria down to 120 f~et, and will endeavor to do slightly better than that. ~~-~ ~k/ /~~ ~ ~~-~ =~ ~, Justification of the waiver can be found for tile follo:¢inq reasons. (1) The house is classified as a duplex only on a technicality, and it would in fact be unlikely to house more people than a single family dwelling. (2) The proposed svste,..,n will in fact serve only the lower floor of the house, although it is possible that the upper level could be hoo!<ed up to it in the event of problems with the other disposal field. (3) There other site available, and (4) The relatively impervious clay o-~ silt soils prevalent on much of the property should serve as a barrier preventing contamination of tile well. Please contact me if you have any additional questions regarding tile proposed construction plan or the waiver request. We await your response before proceeding with construction. Sincerely, Theodore F. )'Ioore SOILS LOG MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 8;25 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST PERCOLATION TEST PERFORMED FOR: James LEGAL DESCRIPTION: "T'RACT ?ER C fi-VI st f rr WAS GROUND WATER ENCOUNTERED? 17 18 SLOPE 19 20 CE. 3589 ..' COMMENTS DATE PERFORMED: SITE PLAN IF YES, AT WHAT DEPTH? t¢ /¢"r S L O P E Gross Net Depth to Net Reading Date Time Time Water Drop ~o ~ : ~ Z ~.o ' 5, fi' g~OMtf E ED PERFORMED BY: R ~cc.,w 72-008 (6/79) RATE ~0''~:~ (minutes/inch)~ RUN BETWEEN Y'~' FT AND ,~,0 FT v' O~t~ "~ c~At~ I' 3'7'o 13t'' CERTIFIED BY: PRoP · 'ERFORMED FOR: LEGAL DESCRIPTION:.__ 1 2 4 5 7 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L, Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST SLOPE __ OATE PERFORMED:_. )1oc 2L PLAN PER C~' LATIOFJ TEST 10 11 12 13 14 15- 16 17 · 18 - 19 2O COMMENTS PERFORMED BY: 72-008 {6179) WAS GROUNDWA~ DEPTH}' i--tole.--- ~;' X' D" ' Reading Date Gros~ Net I Depth To Net Time Time! Water Drop J2.~Z.S' ~0 2.?9 ~.~7 ,t~ ~ Z:5-S- lO Z ,q~ *Hzo ,:ob- -~ ,3~ PERCOLATION HATE ............. TEST HUN II[IWEFN '~- i' T AND '~ FT // CERTIFIE[) SOUTMCENTRAL RF~'I'ONAL OFFICE 437 'E' STREET, SUITE 200 ANCHORAGE, ALASKA 9950t September 14, 1984 274-2533 Flattop Technical Services Star Route, Box 7380N Anchorage, Alaska 99516 SUBJECT: Class 'C" Well to Septic Ta,~k and Leach Field Horizontal Separation Waiver Tract A-2, Audubon Hills S/D 8 521-WA-032 Dear Sirs: The Department has evaluated the subject waiver request and hereby waives the horizontal separation between the well and septic tank to 120 feet and well to soil sb~orption syste~ to 130 feet. This waiver is valid provided that the proposed absorption arp. a be increased by a factor of 1.5, that a Fernco c~upling or e~utvalent be installed on the pipe connections to the septic tank, that ABS schedule 40 or ductile iron pipe be used from footing to septic tank and that satisfactory water samples are taken for a period of six months as required on the enclosed Certificate to Operate. Sincerely, District Engineer BEE/dd STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION CONSTRUCTION AND OPERATION CERTIFICATE for PUBLIC WATER SYSTEMS APPROVAL TO CONSTRUCT Plans for the construction or modification of d/~/~'~' in pul~lic water system located Alaska, submitted in accordance with 18 AAC 80.100 by have been reviewed and are [] approved. ~,..~. ~..~-,,<~.~.+... . . !,~ conditionally approved (see attached conditions). /"l o ~ ~ ~ [ W [~ c ~ - ·, ~ ~ ~ BY TITLE ~ DATE If construction has not started within two years of the approval date, this certificate is void and new plans and ~_ '~' ' specifications must be submitted for review and approval before construction. B, APPROVED CHANGE ORDERS Change (contract order no. or descriptive reference) C. APPROVAL TO OPERATE Approved by Date The "APPROVAL TO OPERATE" section must be completed and signed by the Department before any water is made available to the public. The construction of the ~{--/3rS~' ~ ' ~ ~-/- L ~ j~ ~ C.'~- ~ - "7____ public water system was completed on / ? ~ ~[ (I w I ~ ~7 ~ (date). The system is hereby granted interim approval to operate for 90 da~,s following the completion date. BY TITLE DATE As-built plans submitted during the interim approval period, or an inspection by the Department, has confirmed the system was constructed according to the approved plans. The system is hereby granted final approval to ~' TITLE DATE 184~07 (Rev. 11183) DISTRIBUTION: 1. WHITE - ENGINEER (Complete Section C) 2. YELLOW - WATER SYSTEM FILE (Complete Section C) 3. PINK - ENGINEER/MUNI-BOROUGH (Complete Section C) 4. GOLDENROD - MUNI-BOROUGH (Compl®te Section A) Certificate of On -Site Systems Approval Parcel I.D. 015-231-65 1. GENERAL INFORMATION Expiration Date: #",� G 1 , 20-9- Complete 0.2 Complete legal description Audubon Hills, Tr A2 Location (site address) 12101 Audubon Drive Currentro ert s Brian Miller (907)299-6555 p p y owner() Day phone Mailing address 12101 Audubon Drive, Anchorage, AK 99516 Real estate agent Day 11 phone 2. TYPE OF DWELLING: g Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well n Private Septic no Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Received by: Date: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 550 Waiver Fee $ Date of Payment 1 i 1 aoa 1 Date of Payment Receipt Number Receipt Number COSA # 0 S L a 1 3 Waiver # Distance: 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted. Name of Firm Forge Engineering Phone (907) 522-7773 Address 1399 W. 34th Ave Suite 101, Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller, P.E. (M.J.) Date 11 /10/2 1 OF ' ' •'�'A(„� til oo.•.`P• • •F 49 TH 6. DSD SIGNATURE ..-. .-,. System #1 Approved for 4 Y pp bedrooms '-'''"', •'• System #2 Approved Benjarri,�Schiller S• �� Y for bedrooms �¢ �sl • CE 12592 AFA Disapproved ���F�Fo''• •'' �`v*� pROFESSIONP -® Conditional approval for bedrooms, with the following stipulations: By:6zdv Original Certificate Date: / 2O11.2- 0 ;z J The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory x Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet It fill((((((((( 111 ON-SITE iq'-- VVATER AND G–Tr.< .,iER �� J� PROGKAM 0,0* By:6zdv Original Certificate Date: / 2O11.2- 0 ;z J The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory x Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA Checklist blue sheet COSA Checklist yellow sheet COSA Checklist Legal Description: Parcel ID: If more than 1 septic system on lot: COSA Checklist # of Structure served by this system A. WELL DATA Well log is filed with Onsite (or attached) Date drilled Total depth ft Cased to ft Sanitary seal is functioning correctly Wires are properly protected Casing height (above ground) in. Date of flow test for COSA Static water level at beginning of test ft. Well production at time of test gpm Water storage tank volume gallons Well disinfected for coliform test?Yes No Coliform bacteria is Negative Nitrate mg/L Nitrate less than MRL (ND) Arsenic ug/L Arsenic less than MRL (ND) Collected by Date of Sample Comments __________________________________________________________________________________ B. TANK DATA Age of tank(s) years Tank type/material Measured operating fluid level in septic tank Standpipes/foundation cleanout per record drawing Date of pumping C. LIFT STATION Required maintenance completed Age of lift station years Lift station material Comments: D. ABSORPTION FIELD DATA ______________________ Which system tested (date installed) ALL standpipes present per record drawing Total measured depth from grade ft (max) Measured depth to pipe invert from grade ft (min) N/A – pressurized field Monitor tubes go to bottom of effective. If not, state depth into effective Code-required soil cover over field System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Adequacy test date Results Pass For bedrooms Fluid depth prior to test in Water added gal New depth in Elapsed time min Final fluid depth in Absorption rate gpd Any rejuvenation treatment (past 12 months) If yes, enter date Comments/Deficiencies: **Note engineer comments below Audubon Hills Sub, Tr A2 015-231-65 1.6 UNKNOWN *50'4"■ *40+■ 7.03■ ■■ 18+ Forge Engineering 11/9/21 25 11/2/21 *(No well log) Depths taken from previous 2014 COSA. Well Camera'd 11/30/21 and verified no perforations above 40'. 2 Septic/Plastic n/a ■ 9/10/21 Drain Masters Wide Trench 10/16/2019 n/a ■ 3.3/3.6 2.8/3.1* ■ ■ *2" of insulation present above trench. COSA Checklist yellow sheet E. SEPARATION DISTANCES From Private Well on Lot to:(Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100’ Yes if No ft Neighboring Tank > 100’Yes if No ft Absorption Field on Lot > 100’Yes if No ft Neighboring Absorption Fields > 100’ Yes if No ft Community Sewer Main > 75’Yes if No ft Community Sewer Manhole/Cleanout > 100’ Yes if No ft Private Sewer/Septic Line > 25’Yes if No ft Holding Tank > 100’Yes if No ft Animal Containment > 50’Yes if No ft Manure/Animal Excreta Storage > 100’ Yes if No ft From Septic/Holding Tank on Lot to:(Please enter distances if less than required) Building Foundations > 10’Yes if No ft Property Line > 5’Yes if No ft Absorption Field > 5’Yes if No ft Water Main > 10’Yes if No ft Water Service Line > 10’Yes if No ft Surface Water > 100’Yes if No ft Wells on Adjacent Lots: Private Wells > 100’Yes if No ft Community Wells > 200’Yes if No ft If septic tank is under driveway comment below From Absorption Field on Lot to:(Please enter distances if less than required) Building Foundation > 10’Yes if No ft Property Line > 10’Yes if No ft Water Main > 10’Yes if No ft Water Service Line > 10’Yes if No ft Surface Water > 100’Yes if No ft If absorption field is under driveway comment below Wells on Adjacent Lots: Private Wells > 100’Yes if No ft Community Wells > 200’Yes if No ft F. ENGINEER’S COMMENTS G. ENGINEER’S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. 11/10/21 ✔✔ ✔ ✔ ✔ Unknown* ✔ ✔ ✔✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ✔ ** System installed 10/16/2019. Both trenches completely dry on 11/9/21 * Well and section of sewer line installed prior to 1983 when 25' separation code established. ✔ MUNICIPALITY OF ANCHORAGE    DEVELOPMENT SERVICES DEPARTMENT    907‐343‐7904  On‐Site Water and Wastewater Section                                                                                           Fax: 343‐7997  www.muni.org/onsite         Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org      Nitrate Advisory   Certificate of On‐Site Systems Approval # OSC211663  Subdivision: Audubon Hills, Tract: A2  A water sample revealed a nitrate concentration of 7.03 milligrams per liter (mg/L).   The  Environmental  Protection  Agency  (EPA)  has  established  a  maximum  contaminant level (MCL) of 10.0 mg/L for public drinking water systems.  While  private wells are not subject to this regulation, EPA standards are based on existing  health information and can therefore be used to gauge the relative quality of water  from private wells.  Since nitrates are known to slowly increase, we recommend  you monitor the water quality.  Please see the attached “Nitrate Fact Sheet” for  important information regarding nitrate.  This advisory must be attached to all copies of the subject Certificate of On‐Site  Systems Approval.                                 Mailing Address: P. O. Box 196650 * Anchorage, Alaska 99519‐6650 * www.muni.org  Nitrate Fact Sheet  From Northern Testing Laboratories, Inc.  Nitrate is a negatively charged compound of nitrogen and oxygen, which is very soluble in water.  Nitrate  is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.  SOURCE:  Nitrate is a major component of fertilizer and wastewater.  Often the nitrate is in the form of  ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the  oxidized form known as nitrate.  Sources of nitrate from wastewater include urea, ammonia cleaners,  food solids, and bacterial cells.  It may also result from the breakdown of organic matter buried in the soil.  TOXICITY:  Nitrate is generally not toxic to adults or children over the age of two or three years, but is  associated with a potentially fatal infant disease called methemoglobinemia.  In the digestive system of  young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood  stream.  There it combines with the hemoglobin and interferes with the ability of the blood to carry  oxygen.  For this reason, methemoglobinemia is referred to as “blue baby” disease.  The EPA limits the  concentration of nitrate in public drinking water supplies to 10 mg/L.  The standard has been lowered  from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.  TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home  water treatment systems such as softening or iron filtration does not readily remove nitrate.  The best  method for limiting nitrate in well water is source control.  This can include avoiding overdosing of  fertilizer near the well and maintaining good separation distances between septic tank leach fields and  the well.  A special anion exchange filter that contains a medi a with a strong affinity for negatively charged  ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.  TESTING:  Nitrate analysis is usually done by one of the several  “wet  chemical”  methods  using  a  spectrophotometer to read the final color endpoint.  Specific ion electrodes also can be used to detect  the activity of nitrate in water.  This laboratory uses several different wet chemical methods approved  under the public water supply laboratory certification program.  They also have test kits available, which  the laboratory uses to perform an inexpensive “screening test”, and with which the homeowner can  monitor the change in nitrate levels from their well.  They recommend comparing the test kit results  against a certified analysis from the lab occasionally to verify the accuracy of the kit.  We recommend  using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.          Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchorage.ak, us (907) 343~7904 _O CERTIFICATE OF HEALTH AUTHORITY APPROVAL Parcel I.D. ORS"- ~ 31 - 1.' 'GENERAL iNFORMATION · Complete legal des~,fiption T'~ ~ c.;- /} -~,3_ · Location (site address or directions) ) ~ I o I Current Property oWner(s) FOR A SINGLE FAMILY. DWELLING Expiration Date: /.,~. - ,.5'-' O ~ Lending agency g,~-~- ~q~4.,z, c.,~,,,' 'r't ~' ~ ~ Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: ~ 3. T~PE OF WATER SUPPLY: ' Individual Well Individual Water Storage Community Class Well Public Water System TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA} based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water suoply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid fcr 90 days from the date of issue for prcperties served by a private or Class C we!l and may be reissued with new water sample results. (Certificates may be reissued for a pedod of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Munic!pality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water suJjj~ and/or wastewater disposal system is(are) safe, func*Jonal and adequate for the number of bedrooms ai~J~e of structure indicated herein. I further verify that based on the information obtained from the Municil~J"~'"'~'~chorage flies and from my investigation and inspection, the on-site water supply and/or was!e~/~fisposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, .~t~fations in effect at the time of installation. · ":~la~e afFirm $&SENGINEERING Phone I~ c~y_ ,~/7~ i,'u.~4 Eagle K~ver L~p Road No. 204 Address £aqie River, Alaska 99577 Engineer's Printed Name /~ D ~1 ~.,,%7- ~'. C',D ~,~ ~ DSD SIGNATURE I/ Approved for /.../L. Disapproved. Conditional approval for Date c~ / 3 /o ~-- bedrooms. bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: : :. MuniCipo!!ty of Anchorage Development Services Department Building ~afety Division On-Site Water & Wast~vater Program. 4700 8outl~ Bragaw SL P.O. Box 196850 Anchorage. AK g951g-6650 www. cLanchomge.ak.u$ (907) 3437604 HEALTH AUTHORITY APPROVAL CHECKLIST A. W EU. DATA Wen type ~,v4r¢ Date completed Total dep~ ~'"0 IfA, B, or C provide PWSID # Wail Log (Y4~) ~, o Wires propa~ prOtec~) ¥~ / Casing height (above ground) · ~ q ~- in. FROM WELL LOG ' AT INSPECTION Static water level .~ o ft. ~ O ft. Wail production ~' '+ g.p.m, ill- ~ g.p.m. WATER ,~o~tPLE RESULTS: colonies/100 mL . Nitrate mgJI. Ottter becteda colonies/100 nj. ' AmenW-- - . ,,e.n. B. SEPTIC,qtOI nlNG TANK DATA Tank ,Ize )~ ~- 0 g~l+ '.,:; .. Number of Compartments Fo~tdaUon dieanout(~,)N)9j' e'~"~Depresmon'~'"~t* r,,,~over tank (Y~) Date of pumping ~'/~"/o'3. Pumper ! SeA C. ArtSORPTION FIELD DATA ~' Date'installed )~/~.,/~¥' Soilrating (g.p.dJft~or~/bdrm) ~'5'- Systemtype Lengl~ ~..~//a- ft. Width ~ 9 ft. Gravel below pipe Totaldepth ~/ ft. Eff. abeorptJonarea 5'0/ ft2 Monltodngtube ~',e~ Depmssionoverfieid Date of edequacy test ~131/e~" ResultsTi~Fail),P.4$$ For ~ bedrooms Fluid depth in absorption field before testo~ '~ in. Water added ~o ~T gal. New depth '7 in. ElapaedTime:l~'0 min. Final fluid depth ~' in. AbsorpUonmte >= ~oOO g.p.d. Any mjuvenatlon tmatment (past12 mo.) (Y/N & type) /~,~e. ~c~o-,,-' Ifyes, givedate D. UFT STATION Date installed Size in gallons 'Pump on" level at in. 'Pump off' level at Datum Cycles tested E. SEPARATION DISTANCES Manhole/Access (Y/N) f-Ilgh water alarm level at Meets alam~ & ~ax:ult requirements? irt. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot I 3 ¥ Absorption field on lot ~ 3 ~' Public sewer main A///~ On adjacent lots ! ~0 "/' On adjacent lots /~0 /'+- Public sewer manhole/cteanout Holding tank r~//,4 SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: ' Building foundation ~ ~ Property line ~' ~f- Water main A//,4 Water sewice line Wells on adjacent lots / oo .4- SEPARATION DISTANCE FROM.aBSORPTION FIELD ON LOTTO: Property line J 0 ~ Water Service line /0 ~ F. COMMENTS Building foun.~tion Surface water Wells on adjacent lots /00 ~/- surface water ' ,/o o Water main ' O~,eway, paWJ.g/ve~de ~rage' Waiver Fee $ Date of Payment Receipt Number Date of Payment Receipt Number (Rev. ~2~0~) conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name AD(}~/-~,7 ~'' ~'0 ~-'~,' jVlunicipality of Artchora e P.O. BOX 196650 ANCHORAGE, ALASKA 99519-6650 (907) 264~1~kx 4 7 4 4 TONY KNOWLES, MA YOFt DEPARTMENT OF HEALTH & HUMAN SERVICES January 8, 1987 Mr. Jim Duggan 3701 Eureka Anchorage, Alaska 99503 Subject: Tract A-2 Block 2 -Audubon Hills Subdivision Health Authority Approval Pursuant to our telephone conversation this date, this will furnish official notice of the revocation of the Health Authority Approval Certificate on your residence located on Tract A-2 Block 2 Audubon Hills Subdivision. Unbeknown to the undersigned, Ms. Susan Oswalt advised you (just prior to her leaving on vacation) that she would issue a letter to your financing entity that the old crib system had been disconnected and abandoned as soon as she received a statement to that effect from a registered engineer. She received a copy of a letter from Quadra Engineering, Inc. addressed to you dated December 16, 1986, advising that their inspection revealed that a sewer line had been disconnected (plugged off) on a line which entered an old crib located near an apparent easement between Lot 1 and Tract A-2. Further discussions between ~Ms. Oswalt and Quadra revealed that there is no indication or proof that the old crib was properly abandoned. There are apparently still some unanswered questions as to the disposition of the wastewater from the upstairs portion of the house. Last and certainly not least, the original approval to the Health Authority Approval Certificate was a conditional approval made for three (3) bedrooms contingent upon the following conditions: "the old cesspool on Lot 1 must be properly abandoned and inspected prior to July 1, 1985. Proof of disconnection of line is required." It has actually been ninetneen (19) months since Quadra Engineering provided the inspections, tests, file search data and information in support of the Health Authority Certificate. Mr. Duggan January 8, 1987 Page Two In view of all of the above, effective this date, this department is revoking the subject Health Authority Approval Certification and suggests that you contact Ms. Oswalt if you desire to pursue this any further. S~rel~ y. ~, Program Manager On-site Services CC: Michael Anderson Quadra Engineering 401 East Fireweed Lane Anchorage, Alaska 99503 PS Form 3800, Feb. 1982 . U.S.G.P.O. 1984-446-014 . r- ii o~ ~' _~ ~- ~ ~ · o ~ m MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEALTH CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date 5-- £ 8- 8 5 1. GENERAL INFORMATION (a) Legal Description (include lot, block, subdivision, section, township, range) Tract A-2 A~u~on Hills Subdivision Se0.23, TWP 12N R3W Location (address or directions) L2L'~L Audubon (b) Applicant Name Jim Duggan __ Telephone: Home 562-7141 Business Applicant Address 370]_ Eu[aka AB_borage, Alaska 99503 (c) Applicant is (check one): Lending Institution []; Owner/builder k-----I; Buyer I-1; Other [] (explain); (d) Lending Institution Telephone Address (e) (f) Real Estate Company and Agent Address Telephone Mail the HAA to the folio,wing address: TYPE OF RESIDENCE Single-Family ~ Multi-Family [] Number of Bedrooms 3 Other _Single Family According to owner WATER SUPPLY Individual Well [] Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. SEWAGE DISPOSAL Onsite [] Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. Page 1 of 2 72-025 [ 11,84) ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this ins~p~ection. .--.. Name of Firm O/Lltq¢~¢¢- ~. ik~;,i~'-~"'t~1~D Telephone Z. '7/,~," .¢'7 ?f9 Address ~/'0/ '-~, ~IIIL~(.~I ~'I~'"""~ ~,../~(;.,"' /~l~l~¢t~O~L~, ~,~'! t~I~ , Engineer's Seal L~HEP APPROVAL , A~areve~for //-~z~-~(,~._/ bedrooms by ' Approved Disapproved Conditional Terms of Conditional Approval Lr~._~ ~z£%r,f¢c:¢-Z_ 0~/ /. o %' Date CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-02,~ ( 11184~ HEALTH AUTHORITY APPROVAL (HAA) CHECKLIST- FEBRUARY 1984 q~Jl 264-4720 Legal Description: Trac~Lg~I~d~w~Dj~ Subdivision Sec 23 WELL DATA Private If A, B, C, D.E.C. Approved (Y/N) Date Completed 7/78 (AC&or~inq. _ to / ADEC) 33 ' + Deptt'f of Grouting Private Yield Un ]cm o ~'~ Pump Set At Unl~nown Sanitary Seal on Casing (Y/N) Depression Around Wellhead (Y/N) Well Classification Well Log Present (Y/N) No Total Depth $0' 4" Cased to Static Water Level 30' 2" Casing Height Above Ground 18" Electrical Wiring in Conduit (Y/N) Y Separation Distances from Well: To Septic/Holding Tank on Lot 130' To Nearest Edge of Absorption Field on Lot To Nearest Public Sewer Line Not in Area Cleanout/Manhole Water Sample Collected by Mc F,~r/rTcm Water Sample Test Results s~,~.~,~rp 140' ; On Adjoining Lots 200~ ; On Adjoining Lots 175' To Nearest Public Sewer To Nearest Sewer Service Line on Lot ; Date 5/16/85 N/A __ Comments Probed to find total depth. Pumped at 8 qpm for 30 min- draw down was 3'5". There is no reason to believe the casing is less than 40 feet-However it was hard, to determine the casing below the water level. Date Installed Prior to Size UnknoWn No. of Compartments Unknow~ ~ Standpipes (Y/fN'~967)'- Y Air-tight Caps (Y/N) N Foundation Cleanout (Y/N) Depression over Tank (Y/N) N Date Last Pumped 7-24-84 Pumping/Maintenance Contract on File (Y/N) N ;for Holding Tank High-Water Alarm (Y/N) N/A Temporary Holding Tank Permit (Y/N) Separation Distances from Septic/Holding Tank: To Building Foundation 8,7' To Disposal Field 7 2 ' To Stream, Pond, Lake, or Major Drainage To Water-Supply Well 125' To Property Line 20 To Water Main/Service Line 1 IQ' Course Comments VOl ~7_~me ~oem-c ~o exist however pumuin~ records Page 1 of 2 72-026(11/84) MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENTAL p~_ ;ON 1985 RECEIVED C. ABSORPTION FIELD DATA Soils Rating in Absorption Strata See below ~ Type of System Design Pit or Tank Date Installed Prior to 1967 Width of Field Dimensions No Length of Field Unknown Depth of Field Unknown Gravel Bed Thickness Unknown N Standpipes Present (Y/N) N Date of Last Adequacy/est Adequacy Information on File Square Feet of Absorption Area Depression over Field (Y/N) Results of Last Adequacy Test Separation Distance from Absorption Field: Unknown To Water-Supply Well 137' To Building Foundation 99' Lot 40' To Water Main/Service Line 122' To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area Comments Absorption System is a crib. To Property Line 10' To Existing or Abandoned System on ; On Adjoining Lots 30' To Cutbank (if present) 155' None in Area 30' Absorption is 85 sq ft/BDR in Area. D. LIFT STATION - Non e Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** Signed ~/('F''~I certify that I have clle~ed,~ateVerified, or conformed to all~.%,_./~,~/(~ 5"MOA and HAA guidelines in effect on the date of this inspection. Company .(~)_~..~)YJ,4~ --~6/~... MOA No. S'~' ~-" ~? Receipt No..~. Date of Payment Amount: $ Page 2 of 2 72-026 (11/84) Engineer's Seal · ~ '-~.~' ~ ' MUNICIPAEITY OF ANCHORA(~E ' ' j /~- DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION 825 L Street - Anchorage, Alaska 99501 // ENVIRONMENTAL ENGINEERING DIVISION Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAL WATER AND SEWER FACILITIES DIRECTIONS: Complete all parts on page 1. Incomplete requests will not be processed. Please allow ten (10) days for processing. 1. PROPERTY OWNER I PHONE VIAl LING ADDRESS PROP RESIDENT (If different from above) PHONE ~ff" &/ Y("" ' ' PHONE 2. BUYER MAILING ADDRESS - ~ 3. LENDING INSTITUTION . ' ! PHONE ,---, . _,..?. 4. REALTOR/AGENT ~ . .........~,~ ~,.j~) r~.- ~ ,/,,'~,~ P. HONE MAI LIN G ADDR ESS 5. LEGAL DESCRIPTION STR E ET I ON TYPE OF RESIDENCE NUMBER OF BEDROOMS [] One [] Four ~ SINGLE FAMILY [] Two [] Five [] MULTIPLE FAMILY [~ Three [] Six [] Other 7. WATER SUPPLY INDIVIDUAL~ [] COMMUNITY [] PUBLIC UTILITY * ATTACH WELL LOG. A well log is required for all wells drilled since June 1975. For wells drilled prior to that date,~give well depth (attach log if available.) " ; '~ ' ~ ' ' 8. SEWAGE DISPOSAL SYSTEM INDIVIDUAL/ON-SITE** [] PUBLIC UTILITY **If individual/on-site, give installation'~ate ~ '': ~ ~ If system is over two (2) years old an adequacy test is required by this Department. NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED. THIS SIDE FOR OFFICIAL USE ONLY DATE RECEIVED INSPECTION APPOINTMENTS TIME TIME TIME DATE DATE DATE INSPECTOR INSPECTOR INSPECTOR DIRECTIONS: NUMBER OF BEDROOMS 1. TYPE OF RESIDENCE [] SINGLE FAMILY [] MULTIPLE FAMILY [] ONE [] THREE [] FIVE [] TWO [] FOUR [] SIX [] OTHER 2. WATER SUPPLY [] INDIVIDUAL [] COMMUNITY [] PUBLIC UTILITY Connection Verified 3. SEWAGE DISPOSAL SYSTEM [] INDIVIDUAL/ON -SITE []PUBLIC UTILITY Connection Verified I-~Septic Tank or [] Holding Tank Size: If Tank is homemade give dimensions: TYPE OF TANK TOTAL ABSORPTION AREA 4. DISTANCES WELL TO: PERMIT NUMBER DEPTH OF WELL DATE DRILLED LOG RECEIVED PERMIT NUMBER DATE INSTALLED INSTALLER SOILS RATING MANUFACTURER MATERIAL Absorption Area to nearest Lot Line Septic/Holding Tank IAbsorption Area ISewer Line INearest Lot Line 5. COMMENTS [~PPROVED FOR ,~ BEDROOMS [] CONDITIONAL APPROVAL (letter must accompany certificate) [~P'~DISAPPROVED LEGAL DESCRIPTION 72-010 (Rev. 3/78) R&M CONSULTANTS, INC. 5024 CORDOVA · BOX 6087 · ANCHORAGE, ALASKA 99502 · PH. 907-279-0483 · TLX. 090-25360 September 18, 1978 R&MNo. 851590 Mr. Gerald Wright c/o Alaska Pacific Bank P.O. Box 420 Anchorage, Alaska 99510 ANCHORAGE Attention: Linda Re: Adequacy Test on Existing Sanitary Sewer System; Tract A-2, Audubon Hills~ Subdivision, Anchorage, Alaska Dear Mr. Wright: Per your agent's request of September 12, 1978, we conducted a test of the sanitary sewer system on the above described property. The septic tank was pumped prior to the performance of the test on the seep- age pit. During the test the liquid level in the seepage pit was measured before and after the addition of 1000 gallons of water. Ail liquid levels were measured from ground level and are shown in the following table: Initial Water Second 24 hour Total Reading Added Reading Reading Drop (gallons) 4.65' 1000 4.15' 5.08' 0.93' The water level rose 6 inches with the addition of 1000 gallons of water, indicating a capacity of 166.7 gallons per inch. Twenty-four hours later the liquid level was again measured and found to be 5.08 feet. It had dropped 0.93 feet or 11.2 inches. This indicates an average effluent acceptance rate of 1867 gallons per day for the surrounding soils. If the 3 bedroom resi- dence on the property is to house 6 people, the average load on the system can be expected to be 450 gallons per day. We can therefore conclude that the system is disposing of effluent at an adequate rate for a 3 bedroom residence. ANCHORAGE FAIRBANKS JUNEAU VALDEZ WASILLA September 18, 1978 Mr. Gerald Wright Page -2- We appreciate this opportunity to be of service to you. Please contact us if you have any questions regarding this letter or if we can be of additional service to you. Very truly yours, R&M~NSULTANTS, INC. Gary,S. Smith Seni~ Geologist GS/kah/12-C