Loading...
HomeMy WebLinkAboutMOUNTAIN PARK ESTATES BLK 8 LT 10Mountain Park sta Block 8 Lot 10 #017-391-32 -Nan~ Municipality of Anchorage Page ._.~._/of DEPARTMENT OF HEALTH AND. HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 e Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number:. 7~,b-/5"$1 I N°"~'~: LEGAL DESCRIPTION Township: WELL: r.,ta~silication (Private. A,E.C): Subdivision: · I Total Deptl~; Cased To: Ft. Ft. Date Orillech Slavic Water Level: Ft. Pump Set at.` Ca~ing Heign! Above Ground: GPM F. Ft. Driller: Yiel~ SEPARATION DISTANCES Well SudaCe Water Lot Line Foundation Curtain Drain PID Number: O~?3~II~Z'" Wastewater System: 0 New J~,Upgrade ABSORPTION FIELD ~ Deep Trenct~ SOil Rating: , t/.~" OPD/Sqf Ftc, Fill addaa i~ove orlgi~ grade: Ftr ;Grovel wide; To~l ab~fion Ins~llec Shallow Trench O Bed O Mound o Other Total Oepm from original gr~le: _ /Z, ~'~ 13,0 Gravel depti~ beneath_pipe Grovel length; ~ Number of IIn~; D~ ~ lin~ Pipe mamdah AS~ TANK Manufacturer. in gallons: Materl~: Number o! Compartments: LIFT STATION in gallonS: "Pump on" legal at: Pump Make & Mod~ Electrical Inspections p Hig~ water alarm aU iotionan~ BENCH MARK Dascdption: Inspections performed by: /~:,4 Dates: 1st ~ 2nd Department of Healt~h/~d Hu~a~n~S~/rvices approval · ,iewed and approved by://~~ ~-i?~ ~//,('~'~' ~---Date: Permit Number:. Municipality of Anchorage Paga Z. of DEPARTMENT OF HEALTH· AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P,O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4744 On-Site Wastewater Disposal System and/or Well Inspection Report ,, .j PLAN AS-BUILT SCALE 1" = 20' A '7/£ cc· ~: ~ ~" .~-? Municipality of Anchorage Page '~ ,,of DEPARTMENT OF HEALTH AND. HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 · Anchorage, Alaska 99519-6650 · Telephone: 343-4?44 On-Site Wastewater Disposal System.and/or Well Ins, pection Report Permit Number: ~,~/c),~, O ~L~ . PID Number: OI7~)I~Z'" mz~ MEMORANDUM DATE: October 21, 1996 TO: On Site Services Engineer, MOA- DHHS FROM: Mike Anderson, P.E. SUBJECT: Lot 10, Block 8, Mountain Park Estates Subdivision Pern-fit No. SW960348 Test hole Depth to Prove Lack of Impermeable Layer The contractor on this project, A Plus Home Services, was unable to deepen the test hole to a depth of 20' due to the type and size of equipment he operates. I have therefore included the test hole log completed by R & M Engineering placed on the lot in 1978. This log shows permeable soils to a depth of 20'. Tiffs log should be verification that no impermeable layer is closer than 6' below the bottom of the new trench. In addition, the well log for the lot indicates permeable soils to more significant depths. The information contained on the well log and the R & M test hole provide verification of the lack of an impermeable layer within 6' of the bottom of the absorption trench. MUNICIPALITY OF ANCHORAGE ~_~,-j~ DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 \~--~-~ ANCHORAGE, ALASKA 99519-6650 \~ ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT ~O' \~X~ PERMIT NUMBER:SW960348 DESIGN ENGINEER:ANDERSON ENGINEERING OWNER NAME:SAGAN JEAN S OWNER ADDRESS:6066 BRISTOL DR ANCHORAGE, AK. 99516 PARCEL ID:01739132 DATE ISSUED:10/ll/96 EXPIRATION DATE:10/ll/97 LEGAL DESCRIPTION: MOUNTAIN PARK ESTATES BLK 8 LT 10 LOT SIZE: 32800 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: THIS PERMIT IS FOR THE CONSTRUCTION OF: DISPOSAL FIELD /SEPTIC TANK SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80) . 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. SPECIAL PROVISIONS: DURING CONSTRUCTION EXCAVATE TEST HOLE TO A DEPTH OF 6FT. BELOW BOTTOM OF PROPOSED DRAINFIELD, LOG THE SOIL STRATA AND SUBMIT SOIL LOG WITH ASBUILT/INSPECTION REPORT. ISSUED BY: . l~~I~ ' October 1, 1996 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 Subject: Lot 10, Block 8, Mountain Park Estates Subdivision Septic System Design Impacts to Adjacent Properties Dear On Site Services Engineer: The absorption trench on the subject lot failed a recent adequacy test and must be replaced. The area on the lot available for a replacement system is very limited as shown on the attached drawings. We are proposing to place the new absorption trench at the location indicated with a flow diverter at the old absorption trench for future use if required. The limited area available results in the layout shown on the site plan. It will not be possible to maintain the minimum separation distance required between the new trench and the abandoned trench at all locations. Substantial benefit is gained, however, by leaving the old trench in place due to the limited area available on the lot for septic systems. Should the new trench ever fail, the old trench can be put back in service. We therefore request the separation distance between the old and new trench be waived in this case. A percolation test completed by S & S Engineers in 1985 indicated an absorption rate of 27 minutes per inch. We were unable to duplicate this rate with our test and have designed the trench based on a slower rate of 40 minutes per inch. A test completed by R & M Engineers in 1978 indicated a rate of 9 minutes per inch. Their testhole was completed to 20' below the surface and indicated no impervious layer or bedrock. We are relying on their test to satisfy the requirement for 6' from the bottom of the trench to bedrock. None of the testholes encountered groundwater nor is any anticipated. The existing septic tank will be exposed and checked for any leaking. It will be reused if it is found to be structurally sound. It will be replaced if any imperfections are noted or any leakage is found. Lot 10, Block 8, Mountain Park Estates October 1, 1996 Page Two If the system is constructed as designed the following statements can be made: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserved space, either surface or subsurface, on any lots located in the area. The system, if constructed as designed, will drainage patterns in the area. The current maintained. have no adverse impact on drainage pattern will be Sincerely, Michael E. Anderson, P.E. Attachments . AI..P~IE AREA MAP SCALE 1" -- 100' SITE PLAN SCALE 1" = 30' SYSTEM PLAN NO SCALE SCOPE OF WORK: 2. 3. 4. 5. Expose the Existing Tank and Verify its Integrity for Continued Use. Intercept Existing Line Out of Tank and Place Double Cleanout. Place Zabel Flow Diverter at Existing Line and Close Flow. Place New Distribution Line As Shown. Maintain 12' Separation From Existing Trench. LOT 8, BI. OCK 10, MTN. PARK ESTATES SUB. DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Perc. Rate: 50 Min./Inch Application Rate: .45 GPD/SF Deep Trench System Verify Existing Septic Tank 9' Gravel Beneath Dist. Line 3 Bedrooms X 150 GPD -- 450 Gallons Per Day 450 GPD/.45 GPD/SF = 1,000 SF / 18 SF/LF = 56 LF Total Length Therefore: Construct a Deep Trench System With One Lateral a Total Length of 56'. Lateral to Be Placed at 3' Below Ground Surface. NOTE: TYPICAL DEEP TRENCH SECTION Bottom of Trench to be 4' Above Groundwater. Minimum 3' Cover Over Trench. Grade Area Over Trench to Drain PERFORMED FOR: Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST ~(ENGINEER's SEAL) · ¥,,-;Vi,..''~, . ..... , DATE PERFORMh~i~~~ LEGAL DESCRIPTION: ~O~ /~, ~/~Ot.~- ~.~. /~'r/d. Township, Range, Section: ' 7~Af'&~.=. ~,~ SLOPE SITE PLAN WAS GROUND WATER~'JO ENCOUNTERED? IF YES, AT WHAT DEPTH? Oepmt~ Water Atter/ . _. Monitoring? /%/dM~ Bit~ / I Gro.~ Net Depth to Net Reeding Date Time Time Water Drop 10- 11 12 13- 14- 15- 16- 17- 18- 19- 20- COMMENTS -'7'~.~J--~O/-~ PERCOLATION RATE 4/~) (m~nutes/mch) PERC HOLE DIAMETER TEST RUN BETWEEN ~ FT AND '~ FT ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: DATE: 72,008 (Rev. 4t85) IN ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: Lot 10, Block 8, Mtn. Park Estates Subdivision GENERAL: 1. The scope of this project includes exposing the existing septic tank and verifying its integrity for continued use. A new tank will be required if any leaking or other damage is noted. Work also includes abandoning the existing absorption trench by placing a diverter valve and constructing a new 60' long absorption trench with an effective gravel depth of 9'. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000 gallon septic tank must be procured from an approved source and installed at the location shown on the Site Plan if the existing tank is found to be unsound. Lot 8, Block 10, Mtn. Park Estates Subdivision October 1, 1996 Page Two 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop alevel bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Lot 8, Block 10, Mtn. Park Estates Subdivision October 1, 1996 Page Three 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a Municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). Lot 8, Block 10, Mtn. Park Estates Subdivision October 1, 1996 Page Four 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: A minimum of two inspections are required by Municipal Ordinance. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. 'The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide acopy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. MUNICIPALITY OF ANCHORAGE DE :iTMFNI' OF HI=ALTH AND HUMAN SER KS Environmental Health Division 825 "1_" Street, Anchorage, Alaska 99502, Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Address TANKS TYPE OF SYSTEM ~k:TRENCH [] BED [] W, DRAIN ~ OTHER WELLS ~PRIVATE [] OTHER fldentifv) FT REMARKS: DISTANCES SEPTIC TANK ABSORPTION FIELD WELL WELL I '7-.~ ' ._h I I ~> ~- LOT LINE I o~+ t~' ~r / FOUNDATION ,E~~ '-z.~. ' ~ AS-BUILT DIAGRAM ~Show Iocabon el well. sepllc system, property I[aes, Ioundahon, driveway, waler bodies, eW j Scale: ~.~ ,q%. ~,, Inspections_~ao by Dale Municipal and $1sle guideli~:iir~iigt:6n this dale: HealW Departmenl Approval: __ cedily II]at this inspeclJon was perlormed according Io 72-013 ¢;85) D~te Drill~dt 10-29=85 Lot ~ Blko 8 Mt..ark Estates Static Water Level 197 feet Draw Down ~ feet Gallons Per Minute 3 Total Feet of Casing_~ 220 T_j~.Material D~illed: 25 feet to 39 Sand silt Gr v _f'k,L.~L~_ _ to=2.gsc_~L~ 9-~~to ~o12~ l~0.feet to 200 Da~op Gravel. toD_9~L_(]rave1 200 feet to 220 Si~_~Y__T_~9/u'p_Gravel w/water Hefty Drilli~ Box 1553 H Anchorage ,Alaska 99507 .... /~.,~, /~ ~ --~.. ..,, ,..~%~'~' ~1 IC Jc MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 825 L. Street, Anchorage, Alaska 99501 264-4720 SOILS LOG - PERCOLATION TEST [] SOILS LOG PERCOLATION TEST PERFORMED FOR: LEGAL DESCRIPTION: ~"T" IC~ 10 11 12 13 14 15 16 17 18 19 2O No, 1457-E ; COMMENTS DATE PERFORMED: SLOPE SITE PLAN WASGROUNDWATER , \ S ENCOUNTERED? ·~ ~ P IF YES, ATWHAT E DEPTH7 Reading Date Gross Net Depth to Net Time Time Water' Drop PERCOLATION RATE ~'7 (minutes/inch) TEST RUN BETWEEN /'¢ FT AND ~ FT PERFORMED BY: _CERTIFIED BY: DATE: 72-008 (6/79) Dece]~3er 29, 1978 ~t780236 Robert Charles 1234 R Street Anchorages Alaska 99501 Subject~ Lot 10 Block 8 Mountain Park '~" Estaees Subdivision A permit issued by this department for well and/or sewer sys'ten~ has expired° ' Permits are issued on a calend, ar year bas±s~ as stated on the permitt by authority of tn~lczpa.[ ordinance. l:f you have drilled the well, a well log should be sent to this department to document the ±nstallation date. ITl there are any fur%her questions, please contact this office at 264~4720o Stncerely~ Les No Buchholz~ ~%en~or Anv~ronmental Specmalmst LNB/ljw enc: copy of per,nit April 6, 1978 R&M No. 851109 Mr. Robert Charles 1234 R Street Anchorage, Alaska 99501 Subject: Soil Investigation for Sanitary Sewer System, Lot 10, Mountain Park Subdivision, Anchorage, Alaska Dear Mr. Charles: Block 8, At your request of April 4, 1978, we conducted a subsurface soils investi- gation at the proposed location of the sanitary sewer system on the subject lot. The investigation complied with those procedures required by the Municipality of Anchorage Department of Health and Environmental Protection. This investigation, which was accomplished on April 5, 1978, consisted of a test hole drilled to a depth of 20 feet below the existing ground surface. The test hole was sited according to your instructions and its location is shown in attached Drawing A-01. Drilling was accomplished with a rotary drill rig using continuous flight solid-stem auger with an outside diameter of 6 inches. A sample was taken at the depths shown on the soils log in Drawing A-OI. The sample will be held in storage at our lab for approxi- mately six months. In addition, all material brought to the surface by the augers was continuously monitored by an experienced engineering geologist. The topography at the drilling site is generally horizontal. At the time of the investigation the site had original vegetation consisting of birch, willow, alder and spruce. The top of the test hole was located at original ground surface. The soils encountered in the bore hole are shown in the test hole log in Drawing A-01. The symbols used in Drawing A-01 are explained in Drawings B-01 and B-02. This log displays specific conditions encountered at the test location. However, subsurface conditions may vary in other parts of the lot without any apparent surficial evidence of the change. Groundwater was not encountered. Bedrock was not encountered. At the time the hole was drilled seasonal frost was present from the surface to a depth of 8 inches Permafrost was not encountered. ' A percolation test was performed within the bore hole at the depth shown in the attached Table 1. All depths were measured from the top of the hole. The data in Table 1 show average infiltration from the depths indicated to the bottom of the hole. The measured percolation rate was 9.1 minutes per inch. April 6, 1978 Mr. Robert Charles Page -2- We appreciated this opportunity to be of service to you. Please contact us if you have any questions concerning this letter or if we can be of addi- tional service. Very truly yours, R&M CONSULTANTS, INC. Lynne Kosikowski Staff Geologist JMB: LK/kah Jim McCaslin Brown, Ph.D. Head, Earth Science Department Attachments: Drawings A-01, B-01, B-02, Table 1 BORING NUMBER 3. Date Completed: SOIL DESCRIPTION All Samples A PEAT Reddish-brow~l GRAVEL 1.0 ' Small, Rounded to Subangular, Dry 2.0' SAND W/SOME GRAVEL Light Bro~%, Dry, Medimn Dense Fine to Medi%un Grained GP 6.5' SILTY SAND W/SOME GRAVEL Brown to gray, Dry to Slightly Moist, Median Dense SM LOCATION SKETCH ALPINE No Scale NOTE: DISTANCES SHOWN ARE APPROXIMATE AND HAVE NOT BEEN MEASURED BY SURVEYING METHODS· 15.0' S~qDY GRAVEL W/SOME SILT GM Brown, Slightly Moist, Medium Dense - 20' rD. No Water Table Encountered :. s-eeWbo-~.{... SOILS LOG Jl EXPLANATION ~_ ORGANIC MATERIAL Liftle Visible Ice 0:-I0' Vx ~ A,8. "--/CE' DE'SCRIPT/ON (~'Ss, 72,5Z ~%, 85,9 pcf ! ~--' DRY O~NSITY ~ ~ ~WATER CONTFNT ~BLOWS/FOOT BEOROC~ TY~lO~L SO~L~ UOO ~ A.~-AFT~ BORING ~AMPLER TYPE SYMBOLS~ ORGANIC ~'~ S/LT ~ BEDROCK SAND ~ /C~, MASSIVE ROBERT CHARLES ~B. , BORE HOLE LOG GRID. LOT 10 Blk 8 Mt. Park Estat ]PROJ. NO. 851109~ ANCHORAGE, ALAgMA /~ TIME ELAPSED TIME PERCOLATION TEST Robert Charles R&M NO. 851109 INCHES DROP IN INCHES 12:10 0 19.2 12:11 1 19.8 12:12 2 20.4 12:13 3 21.0 12:14 4 21.6 12:15 5 21.6 12:16 6 21.6 12:17 7 22.2 12:18 8 22.2 12:19 9 22.2 12:20 10 22.2 12:25 15 22.2 12:30 20 22.8 12:35 25 22.8 12:40 30 23.4 12:50 40 24.0 1:00 50 25.2 1:10 60 25.8 0 .6 .6 .6 .6 .0 .0 .6 .0 .0 .0 .0 .6 .0 .6 .6 1.2 .6 6.6 Total Drop (Inches) 9.1 Minutes per Inch Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 017.391-32 1. GENERAL INFORMATION Complete legal description HAA# Expiration Date: Lot 10, Block 8, Mountain Park Estates Subdivision Location (site address or directions) 6066 Bristol Drive Current Property owner(s) Thomas & Carrie Buckmeier Mailing address Lending agency Mailing address Real Estate Agent Mailing Address Unless e'~erwise requested, HAA will be held by DSD for pickup. 2, NUMBER OF BEDROOMS: 3, TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class ~ Public Water System 6066 Bristol Drive Anchoraqe. AK 99515 Three (3) O~ O~ 38 l-b/- o~ Day phone 244.5215 Day phone Day phone TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] [] Individual Holding tank r'-] Well [] Community On-site [] [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of HeaIth Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for propedies served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further veri~ that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ord!nances, and regulations in effect at the time of installation. Name of Firm Anderson Enqineerinq Address P.O. Box 240773 Anchora.qe, AK 99524 Engineer's Printed Name Michael E. Anderson. P.E. 5. DSD SIGNATURE J Approved for Disapproved. bedrooms. Phone 522-7773 Date 10117/2002 Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ! 0 - ~ I - 0 ,=~ Municipality of Anchorage ,_o. Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Brag'aw St. v P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-79O4 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: WELL DATA Wall type Private Date completed ~0/29ngs~i Total depth 220 ft. Lot t0, Block 8, Mountain park Estates Date of test Static water level Well production 3 WATER SAMPLE RESULTS: Coliform 0 c~donias/100 mi. Date of sample: 10/7/2002 B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Parcel ID: 017-391-32 IfA, B, or C previde PWSID # __ Sanita~ seal (Y/N) ~_ Cased to 220 lt. FROM WELL LOG ¶0~29/1985 197 f. g.p.m. Wall Leg (Y/N) Y Wiras properly protected (Y/N) Y Casing height (above ground) >t2 AT INSPECTION t0/3/2002 198 ft. 2.7 g.p.m. Nitrate t.5 mgJI. Collected by: MEA in. Other bacteria 0 colonies/100 mi. Date installed 10/31/1985 Tank size t,000 gal. Number of Compartments 2_ Clearmuts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) 14 High water alarm (Y/N) Y Date of pumping 8922/2002 Pumper Anchorage Cesspool Pumping C. ABSORPTION FIELD DATA Date instatled 10/16/1996 Soil rating (g.p.d./fl; or ft;/bdrm) .45 GPD/SF System type Deep Trench Length 65 fi. W~lth 3 fl. Gravel below pipe 9 Total depth 12.5 lt. Eft. absorptk3~ area 1,110 ft2 Monitoring tube Y_ Depression over field 14 fL Date of adequacy test 10/10/2002 Fluid depth in absorption field before test ~_~ in. Elapsed Time: 1~140 min. Final fluid depth 64 in. Any rejuvenation treatment (past 12 mo.) (Y/N & type) N Results (Pass/Fail) Pass For _3 bedrooms Water added451 gal. New depth71.5 in. Absorption rata >= 450 g.p.d. If yes, give date LIFT STATION Date installed 'Pump on" level at __ in. Datum SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot >100. Absorption field on lot >t00. Public sewer main N/A Sewer/septic service line >25' Size in gallons 'Pump off" level at Cycles tasted in. Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots >100' On adjacent lots >100' Public sewer manhole/cteanout NIA Holding tank N/A SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line 4' Water main N/A Water service line >t0' Wells on adjacent lots >100' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line >10' Building foundation >t0' Water Service line >t0' Surface water >100' Curtain drain None Noted Wells on adjacent lots >t00' COMMENTS Lol Une Waiver issued 10/24/96 ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in affect on this date. Engineer's Printed Name Michael E, Anderson. P.E. Date 10117/2002 HAA Fee $ Date of Payment Receipt Number (Rev. 12/00) -' - Oz.. Absorption field >5' Surface water >t00' Water main >t0' Driveway, parking/vehicle storage >25' in. Wa~er Fee $ Date ~ Payment R~ipt Number - .':iI AN ~ ~4 ' . . ·'"~., :: CHORAGE,'A 9952 ~522-7773 ; ~":. :-' 522 6779 (FAX).' October 17, 2002 Thomas and Carde Buckmeier 6066 Bristol Drive Anchorage, AK 99515 Subject: Lot 10, Block 8, Mountain Park Estates Subdivision Well and Septic System Inspection, Testing and Certification Dear Tom and Carrie: At your request we inspected the well and septic system on the subject lot to determine if they met the requirements for certification by the City. Prior to the inspection we inspected the Municipal records and found the septic system was originally constructed in October of 1985 and upgraded in October 1996 and is composed of a 1,000 gallon septic tank and 2 absorption trenches. The first trench constructed in 1985 is approximately 67' long with 6' of gravel. The second trench constructed in 1996 is 65' long with 9' of gravel beneath the distribution piping. A flow diverter valve is in place to control flow to the trenches. The new trench is currently on line and was tested for adequacy dudng our inspection. The accepting soil matedal in the absorption trenches is a tight silty gravel with a percolation rate of 50 minutes per inch. The well was also constructed in June of 1985 and is 220' in depth with 6" steel casing the entire depth. We probed the monitor tube at the end of the westerly trench and found nearly 22" of' water. The monitor tube in the approximate middle of the newer trench and found had 64" of water. We then injected 451 gallons of. water into the post tank cleanout past the diverter valve and the water was distributed to the trench. The water level in the monitor tube rose to 71.5". The water level was checked approximately 24 hours later and was found to have receded to the elevation recorded pdor to the test. We conclude from this test the trench is capable of absorbing the required 450 gallons of water per day and meets Municipal requirements for certification. It must be noted, however, that the lifespan of' a septic system is affected by many variables and no guarantees or warrantees as to the future life of the system are made or implied as a result of. our test. The static water level in the well was measured at 198' below the ground surface prior to our test. Water was allowed to run freely from the well through a hose bib and through a 5/8" hose and measured with a volumeter. Flow was measured at an average rate of' slightly more than 2.7 gallons per minute with the static water level in the well dropping to 206.4'. Once flow from the well was stopped the static water level returned to its original level in an hour. The well is therefore capable of producing in excess of the required 450 gallons per day. A sample from the water system was taken to the laboratory for analysis and found to be free of coliform and other bacteria with only a trace of nitrate content. The well and water are therefore eligible for Municipal certification. Sincerely, Michael E. Anderson, P.E. Attachments 0 EASEMENTS.OF' I~ECORDi.OTHER THAN THOSE 'SHOWN ON 1'HE RECORDED PLAT, ARE NOT ,SHOWN HEREON, MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 Parcel I.D. # CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING 017-39L132 HAA# '~:'lAe"\c'~'~" C GENERAL INFORMATION Complete'legal description Lot'~'l 0, Block 8, Mountain Park Estates Location (site address or directions) 6066 Bristol Drive Property owner Michael A. Cady & Lorraine Farr~phone 345-2450 6066 Bristol Drive Anchorage, AK 99516 Mailing address Lending agency Mailin_g address Day phone Agent Address Day phone Unless otherwise requested, HAA will be held for pickup. Three (3) Y NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual well Community well NOTE: XXX Public water If community well system, provide written confirmation from State ADEC attest- ing to the legality and status of system. 4. TYPE OF WASTEWATER DISPOSAL: NOTE: XXX . Individual on-site -.: , Holding tank Community on-site Public sewer If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72-025 (Rev. 1/91) Front MOA#21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I furtherverifythatbasedontheinformationobtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm Anderson Enqineerinq Address P.O. Box 240773 Anchoraqe, AK 99524 Engineer's signature Phone 522-7773 Date 2/15/99 DHHS SIGNATURE /~ Approved for 3 Disapproved. Conditional approval for bedrooms. bedrooms, with th-e following stipulations: Additional Comments The Municipality of Anchorage Department of'Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional enginee~ registered in the State of Alaska. The DH HS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 72~25 (Rev. 1/91) Back MOA ~1 Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICE'~ Environmental Services Division · FEB 17 1999 825 L Street, Room 502 · Anchorage, Alaska 99501 (9,07) 343-4744 , Municipality ct AnChorage Dept. Health & Human Services Health Authority Approval Checklist Legal Description: Lot 10 ~ A. WELL DATA Well type Private Block 8~ Mountain Park Estates Parcel I.D.: 01 ?-39-132 Log present (Y/N) Y Total depth 220 ', Sanitary seal (Y/N) Date of test Static water level Well production If A, B, or C, attach ADEC letter. ADEC water system number Date completed 10/29/05 Casing height (above ground) ¥ Wires properly protected (Y/N) Cased to FROM WELL LOG 10/29/85 197' 3 220' 2' AT INSPECTION 2/1.3/99 WATER SAMPLE RESULTS: Coliform 0 Nitrate Date of sample: .2/9/99 B, SEPTIC/HOLDING TANK DATA Date installed · 1 0 / 1 3 / 8 5 _ Tank size 1,0 0 0 Foundation cleanout (Y/N) Date of Pumping 9/98 C, ABSORPTION FIELD DATA Date installed 1 0 / 1 6 / 9 6 Length 6 5 ' Width 197' g.p.m. 3 g.p.m. 1.24 mg/L Other bacteria Collected by: MEA Y Depression (Y/N) Pumper Anchorage Number of Compartments 2 N High water alarm (Y/N) Cesspool Pumping Soil rating (g.p.d./ft~ or ft2/bdrm) .45 3 ' Gravel thickness below p pe Effective absorption area 1 , 170': SF Monitoring Tube present (Y/N) Y Date of adequacy test 2 / 13 / 99 Results (Pass/Fail) Pas s Fluid depth in absorption field before test (in.); 3.1 ' Fluiddepth 3.1 ' (ins)Minutes later: 24 Hrs. Peroxide treatment (past 12 months) (Y/N) ~ __ Cleanouts (Y/N) Y N System type Deep Trench 9 ' Total depth 12.5 ' __ Depression over field (Y/N). N For Three bedrooms Immediately after506 gal. water added (in.): 3 · 8 ' Absorption rate = > 450 .g.p.d. If yes, give date 72-026 (Rev. 3/96)* D. LIFT STATION None on Lot Date installed Manhole/Access (Y/N) High water alarm level at* Cycles tested SEPARATION DISTANCES Size in gallons "Pump on" level at* *Datum SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot > 100 ' Absorption field on lot > 100 ' Public sewer main Sewer/septic service line > 25 ' Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Foundation > 5 ' Property line > 5 ' Water main/service line > 10 ' Surface water/drainage > 100 ' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation > 10 ' Property line 4' ~¢* Surface water > 100 ' Curtain drain None on Lot F. ENGINEER'S CERTIFICATION Lot "Pump off" level at* Driveway, parking/vehicle storage area Wells on adjacent lots > 100 ' Line Waiver Issued 10/96 I certify that I have determined thru field inspections and review in conformance with MOA HAA guidelines in effect on this date. Signature Engineer's Name Michael E. Anderson, P.E. Date ~/-~ '>'/~ ¢ Absorption field > 5 ' Wells on adjacent lots > 1 00 ' Water main/service line > 10 ' ;~10' HAA Fee $ Date of Payment Receipt Number 72-026 (Rev. 3/96)* Waiver Fee $ Date of Payment Receipt Number are On adjacent lots > 100 ' On adjacent lots > 1 00 ' Public sewer manhole/cleanout N/A N/A MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES Division of Environmental Services On-Site Services Section P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. # 01739132 1. GENERAL INFORMATION Complete legal description Lot 10, Block 8 Mountain Park Estates 6066 Bristol Drive Location (site address or directions) Property owner Mailing address Lending agency Mailing address Agent Address Jean S. Sagan 6066 Bristol Drive Day phone 786 1531 Anchorage, AK 99516 Day phone Day phone Unless otherwise requested, HAA will be held for pickup. NUMBER OF BEDROOMS: Three 3) TYPE OF WATER SUPPLY: Individual well Community well NOTE: XXXXXX TYPE OF WASTEWATER DISPOSAL: Individual on-site Holding tank Community on-site Public sewer Public water .. , ~ /,/ , <: ,~ If community well system, provide written confirmation from State'AD£C aftest-., ing to the legality and status of system. "' .:, ~, ,-, . XXXXXX ", " < ' NOTE: If community wastewater system, provide written confirmation from State ADEC attesting to the legality and status of system. 72~Y25 (Rev. 1/91) FrOnl MOA #21 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health Authority Approval application shows that the on-site water supply and/orwastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein, lfurtherverifythat based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. NameofFirm Anderson Engineering Phone 563 .7155 Address P,O. Box 240773 Anchorage, AK 99524 Engineer's signature ~¢~-~.c,~, C C/'~1'%~~,-''---'' Date lo/19/96 DHHS SIGNATURE Approved for -~ Disapproved. Conditional approval for bedrooms. b.~orooms, with the following stipulations: The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority Approval Certificates based only upon the representations given in paragraph 5 above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineeCs work. 72-O25 (Rev. 1/91) Back MOA MuniciPality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES Environmental Services Division 825"L" Street, Room 502 · Anchorage, Alaska 99501· (907) 343-4744 Health Authority Approval Checklist Legal Description: A. WELL DATA Well type P/2.1x/~T* .~'~ if A. B, or C. attach ADEC letter. ADEC ~vater system nulnber Log present (Y/N) 'x(' Date completed Total depth ~-~&) / Cased to Sanitary seal (Y/N) ~1/' OIT' Cll 3L. Casing height (above ground) Wires properly protected (Y/N) FROM WELL LOG AT INSPECTiON Static water level /g ,~t t [ ~ , ~/ Well production ~ g.p.m. ~ g.p.m. WATER SAMPLE RESULTS: Coliform O Nitrate /, i g,, ,~.,~ / L~ Other bacteria Date of sample: {~9/%~/~, Collected by: B. SEPTIC/HOLDING TANK DATA Date installed /~/~J }]~ tffTank size Foundationcleanout (Y/N)"y' Date of Pmnping /'/Y/J ~ / q k Pumper C. ABSORPTION FIELD DATA Date installed /O/'tb. [ ~] Cl~ Soil rating (g.p.d./ft2 or ft2podrm) o Length ~ ~ i Width -~ / Gravel thickness below pipe /~OOt9 Nulnber of Compartments Z, Cleanouts (Y/N) Y' Depression (Y/N) ~ High water alarm (Y/N) /NJ System type ~)iz~pT~-txl t2J.4. Total depth l ~,' q3 Effective absorption area /t i ?0 /~, Monitoring Tube present(Y/N) ~'/ Depression over field (Y/N) ~ Date of adequacy test t~ tL-qM (,~ s"'~ Results (Pass/Fail) T'),0, .q, $ For "~/~ bedrooms Fluid depth in absorption field before test (in.); ~ hnmediately after gal. water added (in.): Fluid depth Minutes later: Peroxide treatlnent (past 12 months) (Y/N) (in.) Absorption rate = If yes, give date g.p.d. Date installed ~-~.~_ Size ill galloos , · Manhole/Access (Y/N) ~'""~-~'-~ "Pump off level at High xvater alarm level at* *Datum ~ Cycles tested E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic/holding tank on lot Absorption field oo lot Public sewer main ' Oil adjacent lots · On adjaceat dots Public sexver manhole/cleanout Sewer/septic service line Lift station SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Foundation Property line >/g9 Absorption field '~ Water mai~qservice line ~>/O t Surface water/drainage >]~)~ t Wells on adjacent lots SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation Surface water Curtain drain F. ENGINEER'S CERTIFICATION Water mai~ffservice line Driveway, parkingA,ehicle storage area Wells ou adjacent lots P op -m7 >,,ti) ' I certify that ] have determined thrufield inspections and review are m conformance with MOA HAA guidelines,~ effect on this date. St' nature' ' Engineer's Name /~,Cgd~&~ ~ ~08W30,J " Date I ' q, '-'~" , Date of Payment Receipt Number Date of Payment Receipt Number Rev. 8/95 OSS: haa.wk.doc Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 October 24, 1996 Michael E. Anderson, P.E. Anderson Engineering PO Box 240773 Anchorage, Alaska 99524 Subject: Waiver Request for LOt 10 Block 8 Mountain Park Estates Subdivision Waiver Request #WR960061, PI:D #017-391-32, HA960464, SW960348 Dear Mr. Anderson: Your request for a waiver of the required 10 foot separation between an on-site wastewater disposal system and a lot line has been approved. The waived distance is 4 feet from the absorption field to the west end of the property. This approval applies to the existing on-site wastewater disposal system lot line separation only. Any future upgrade to the on-site wastewater disposal system will require all separations be met or another approval from this department. If there are any further concerns or questions regarding this waiver, please call our office at 343-4744. Sincerely, Robert W. Robinson Civil Engineer On-site Services Program RWR/ljm:Sagan MUNICIPALITY OF ANCHORAGE Department of Health and Human Services On-site Services Section Waiver Review Worksheet WR~ WR960061 PID~ 017-391-32 HA# HA960464 Date Received: October 23, 1996 Legal Description: Lot 10 Block 8 Mountain Park Estates Subdivision Engineer: Michael E. Anderson~ P.E., Anderson Engineering PO Box 240773~ Anchorage~ Alaska · 99524 Applicant: Jean S. Sagan t. Waiver Requested: Lot line waiver of 4 feet from the absorption field to west end of lot line. Permit ~ SW960348 Criteria: 1. Geology: Points: A. Water Table B. Soil Sorption C. Permeability D. Water Table Gradient E. Horizontal Separation TOTAL: Special Conditions: 3. Other: Waiver is Granted: '\//i Waiver is NOT Granted: List Conditions or R~asons for above: Date: / ~'.~.~ By: Name of ~eviewer Rec 9: 02371/3096 Amount: $ 115.00 Date Paid: Oct 23, 1996 October 23, 1995 Municipality of Anchorage Department of Heath & Human Services 825 "L" Street Anchorage, AK 99502-0650 RECEIVED OCT 2 3 19% Dept. Health & Human 8ervJoes Subject: Lot 10, Block 8, Mountain Park Estates Subdivision Septic System As-Built Lot Line Waiver Request Dear On Site Services Engineer: Very little area is available for a septic system on this lot because of the location of the well on the lot and on the adjacent lots. In addition, the new absorption trench was constructed to leave the existing trench in tact for possible future use. The west end of the absorption trench encroaches to nearly 4' of the property line. The majority of the trench, however, is greater than 10' from the line. A waiver to the 10' setback requirement is necessary for the west end of the absorption trench. No easements exist along the property line. In addition, no development on the adjacent property is within 50' of the line. Due to the elevation changes on the property next door the use of the adjacent area for a replacement septic system is very unlikely. It was necessary to crowd the lot line to avoid encroaching into the existing system. We therefore request a waiver be issued allowing a portion of the absorption trench to be approximately 4' from the lot line. Please let me know if you have additional questions. Sincerely, Michael E. Anderson, P.E. MUNICIPALITY OF ANCHORAGE Department of Health & Human Services DIVISION OF ENVIRONMENTAL SERVICES 343-4744 Parcel I.D. # CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY FOR SINGLE FAMILY DWELLING ~-~- &Gl-_%5 HAA# ~ 1. GENERAL INFORMATION (Must be completed prior to submittal) (a) Legal Description (include 10t, block, subdivision, section, township, range) I.mt 10; B~n~.~. ~; Mnu~'(~Jn P~ Estates Location (address or directiens) 6066 Bristol .D.ri~¢;"; 'Anchorage, Alaska (b) Property owner' ~.~-~'~O, ~-,~2 L '~-1 ~,(~ S Telephone: (home) Mailing Aadress (c) Lending Institu{ion GMAO Telephone Mailing AddreSs':- ' Ter'~.y L~. )a~/Loan Officer FORTUNE PROPERTIES/Niel Thomas (d) Real Estate Company and Agent 3000 A Street, Anchorage, AlasEa 99503 Address Business. Telephone 562-7653 ' (e) Mail the HAA to the following address: (or check here ~, if hold for pick up.) List contact person and day phone number below: S & S ENGINEERING/694-2979 17034 Eagl~ River Loop Road, Suite 204 Eagle River, Alaska 99577 2. TYPE OF RESIDENCE Single-Family E~ Number of bedrooms 3 3. WATER SUPPLY Individual Well ~ Community [] Public [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to th' legality and status. 4. SEWAGE DISPOSAL On-site I~ Public [] Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72-025 (Rev. 7/88) Page 1 of 2 · 5. ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION As certified by my sea~ affixed hereto and as of thevalidationdateshown below, J verify that my investigation of this Health Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm Address Date S & S ENGiNEF. R|N'G 17034 Eagle River Loop Road i'~o, · , -,:- ao~77 Eagle River, ~,~ Telephone 6. DHHS APPROVAL Approved for. -..? bedrooms by Approved &~_~._ Disapproved Terms of Conditional Approval Conditional The Municipality of Anchorage Department of Health and Human Services(DHHS) issues Health Authority Approval cerificated based only upon the representations given in paragraph S above by an independent professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHSdo not conduct inspections or analyze data before a certificate is issued. The MunicipalityofAnchorageisnot responsible for errors or omissions in the professional engineer's work. 72-025 (Rev. 7/88) E~ack Page 2 of 2 A. WELL DATA Well Classification Well Log Present (.~¢~, N) o MUNICIPALITY OF ANCHORAGE (MOA) Health Authority Approval (HAA) JCJPALFrY (~HE~,F~4~ - FEBRUARY 1984 NMEN'rAL SERVICES DW1~.~-4744 OCT ]989 RECEIVED '¢ Date Completed Legal Description: [.-¢__.¢r' 1~ ~ ~ If A, B, C, D.E.C, Approved (Y/N) Casing Height Above Ground Electrical Wiring in Conduitq~/N) Total Depth '~'~¢-~t Cased to '~."7--c'* Depth of Grouting Static Water Level ~ ', ~ SEPARATION DISTANCES FROM WELL: To Septic/Holding Tank on Lot / '~"~ ~ Pump Set At Sanitary Seal on Casin ((~_.~N) Depression Around Wellhead ; On Adjoining Lots I ; On Adjoining Lots To Nearest Edge of Absorption Field on,Lot To Nearest Public Sewer Line r~/,~ To Nearest Sewer Service Line on Lot Water Sample Collected by ~--~"~ ~ ~ [~,~=:¢-m¢~. ; Date Water Sample Test Results ~¢~t.~~ To Nearest Public Sewer Cleanout/Manhole Comments B. SEPTIC/HOLDING TANK DATA Date Installed I~''5~ ~¢-~'~ Size Standpipes (C/N) ~ Depression over Tank (Y/~ Pumping/Maintenance Contact on File (Y/N) Holding Tank High-Water Alarm (Y/N) .Air-tight CapsY. C~N) No. of Compartments ~ Foundation Cleanout4~TN) i~ /Date Last Pumped ~!, ; for ¢&//'~ Temporary Holding Tank Permit SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK: To Water-S. upply Well To Property bins T,o Water Main/Serve'ce Line To Building Foundation To Disposal Field I ~=~t ~r t J To. Stream, Pond, LaKe or Major Drainage Course Comment~ A~'' ~o~ ~..- 72-026 (Rev. 7/88) Front Page 1 of 2 C, ABSORPTION FIELD DATA Soils Rating in Absorption Strata Date Installed Width of Field Square Feet of Absortion Area Depression over Field (Y/d~j:) Results of Last Adequacy Test /?~.t,¢ ~:~ Y¢~ Type of System Design'"'~. ,~/4 Length of Field Depth of Field Gravel Bed Thickness Lc, ~ ~:::~,¢¢_.-4~ Statndpipes Present 4::~/N) ~-~ Date of Last Adequacy Test SEPARATION DISTANCE FROM ABSORPTION FIELD: To Water-Supply Well To Building Foundation Lot pA To Water Main/Service Line To Stream, Pond, Lake, or Major Drainage Course To Driveway, Parking Area, or Vehicle Storage Area To Property Line To Existin~ or Abandoned System on Adjoining Lots "~ '~r~ To Cutback (if present) t Comments Date Installed 'Pump On" Level High Water Alarm Level at Tested for Meets MOA Electrical Codes (Y/N) Comments Dimensions Manhole/Access (Y/N) "Pump Off" Level at Vent (Y/N) ~ Pumping Cycles during Adequacy Test. **Check Permitted Bedroom Rating Against HAA Request** I certify that I have checked, verified, or conformed to all MOA and HAA guidelines in effect on the date of this inspection. Signed Company Date MOA No. Receipt No. Date of Payment Amount: $ 72-026 IRev. 7/88) 8ack S & S ENGINEERING 17034 ~ag~ ,,, ................ ,,--, ~gla River~ Alaska 99577 Receipt No. Waiver Fee: $ Date of Payment Page 2 of 2 CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. ANALYSIS REPORT BY SAMPLE for Iqork Order ~ 17012 Date Report Printed: OCT i 89 ~ 13:41 Client Sample ID:LIO BB }40UNTAIN PARK S/D PWSID :UA Colleotod SE? 25 89 @ 15:20 hrs. Received SEP 25 89 ~ 16:00 hrs. Preserved with :AS REQUIRED Client Name : 3 & 3 ENGR Client Acct: SNSENGP P.O.~ NONE RECEIVED Req ~ O~de~ed ~y : Analysis Completed :SEP 27 89 Send Reports to: SupervI~oL:STEPHEN C. EDE 1)S & S ENGR Laboratory Released By : ~.~.'-~--~ ~ 2) Special Instruct: Chemlab Roi ~: 7719 Lab Smpl ID: 5 ~atrix: WATER Allowable Parameter Tested Result/Units ~ethod Limits NITRATE-N 0.60 mR/1 gPA 353,2 10 Samplo ShI4?LE COLLECTED BY gDJ Remarks: i Tests Performed See Special Instructions M)ove UA~Unavailable ND,, None Detected '* See Sample Remarks Above Nh= Not Analyzed LT=Less Than, GT=Greater Than CHEMICAL & GEOLOGICAL LABORATORIES OF ALASKA, INC. TELEPHONE (907) 562-2343 5633 B Street Anchorage, Alaska 99518 Drinking Water Analysis Report for Total Coliform Bacteria TO BE COMPLETED BY WATER SUPPLIER [] PUBLIC WATER SYSTEM I.D.# [] PRIVATE WATER SYSTEM Mailing Address City [ I ~ ' .... Stale Mo. Day Year Zip Code SAMPLE TYPE: ~ Routine Check Sample (for routine sample with lab ref, no, [] Special Purpose .) [] Treated Water [] Untreated Water SAMPLE Time NO. LOCATION Collected Collected READ INSTRUCTIONS BEFORE COLLECTING SAMPLE TO BE COMPLETED BY LABORATORY sYatis shows this Water SAMPLE to be: isfactory [] Unsatisfactory [] Sample too long in transit; sample sho.uld not be over 30 hours old at examinatioh to indicate reliable results. Please send new sample via special delivery mail. Date Received ¢'- 4 ;~-~? Time Received /~ Analytical Method: Membrane Filter * No. of colonies/100 mi. Lab Ref, No, Result* Analyst BACTERIOLOGICAL WATER ANALYSIS RECORD Membrane Filter: Direct Count Verification: LTB BGB Final Membrane Filter Results ~ Reported By'~-~J."---~ -.-~-"-~~ ~.Date TNTC = Too Numberous To Count OB = Other Bacteria Time: P2%RT ONE; OF TWO I:~M~iNDE~R TO FOLLOW Coliform/100ml Collforrn/100ml MUNICIPALITV OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONiVIENTAL PROTECTION DIVISION OF ENVIRONMENTAL HEAI2i'FI CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL OF ON-SITE SEWER AND WATER FACILITY 264-4720 Application Date __~ \ ~ GENERAL INFORMATION (a) Legal Doscription (include lot, block, subdivision, section, township, range) Location (address or directions) (b) Applicant Name ~~ ~;-~% Telephone: Home ~ "' ~ Business Applicant Address ~ '~ ~ ~ ~-~~ -~'~/ .... (c) Applicant is (check one): Lending Institution ~; Owner/builder ~; Buyer ~; Other ~ (explain); (d) Lending Institution Address Telephone (e) Real Estate Company and Agent Address Telephone (f) M;sil the I-tAA to the foltowing address: TYPE OF RESIDENCE Single-Family~C MuLti-Family Number of Bedrooms '~ Other WATER SUPPLY Individual Well¢~-- Community [-~ Public Note: If community well system, must have written confirmation from the State Department ol Environmental Conservation attesting to the legality and status. 4. SEWAGE DISPOSAL ~ Onsite,,~C Public [~ Community [] Holding Tank [] Note: If community well system, must have written confirmation from the State Department of Environmental Conservation attesting to the legality and status. 72 025 {11~84) Page 1 of 2 ENGINEERING FIRM PROVIDING..~PECTIONS, TESTS, FILESEARCH, DAT' .ND INFORMATION As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of thi~ Healtl;~ Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is in compliance with atl Municipal and State codes, ordinances, and regulations in effect on the date of this inspection. Name of Firm . . . Telephone Address Date Approved ~.~ DisapprovedU'' C°nditi°nar~' Terms of Conditional Approval CAUTION The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority Approval certificates based solely upon the representations given in paragraph 5 above by an independent pro~-essional engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending institutions in order to satisfy certain federal and state requirements. Employees el DHEP do not conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. Page 2 of 2 72-025 (I ~/84) MUNICIPALITY OF ANCHORAGE (MOA) HEALTH AUTHORITY APP'ROVAL (HAA) CHECKLIST - FEBRUARY 1984 264-4720 Legal Description: ,MUNICIPALITY OF ANCHORAGE' DEPT. OF HEALTH & ENVIRONMENTAL PROTECTION NOV 1919t -' ,o IV E D WELL DATA Well Classification Well Log Present'(~;~N) Total Depth ¢...'Z.,c~' Static Water Level Casing Height Above Ground Electrical Wiring in ~onduit~,'.,'~N) Separation Distances from Well: t¢~-'Z~'~ ~¢~,-~- If A, B, C, D.E.C. Approved (Y/N) Date Completed ~ c>~¢_.-~ ~ 'E~ Yield Cased to Depth of Grouting Pump Set At Sanitary Seal on Casing ~¢N) Depression Around Wellhead (Y/,¢~ To Septic/14e~ Tank on Lot I '2~-~ ' 4-_ ; On Adjoining Lots To Nearest Edge of AbsorptionField on/Lot ~ ~ ~ ~¢ ; On Adjoining Lots To Nearest Public Sewer Line ,¢ /¢/:~ To Nearest Public Sewer Cleanout/Manhole ~ Water Sample Collected by Water Sample Test Results Comments To Nearest Sewer Service Line on Lot .~..~. 1 4- B, SEPTIC/=H(~'~,NG TANK DATA Date Installed tO~'~ ¢ b:~ Size t ~ Standpipesd~2/N) Air-tight Caps (~N) Depression over Tank (Y/~ Pumping/Maintenance Contract on File (Y/N)~.3//x, Holding Tank High-Water Alarm (Y/N) Separation Distances from Septic/.Meh~-n~Tank: To Water-Supply Well To Property Line To Water Main/Service Line Course No. of Compartments Foundation Cleanout(_(~/N) /Date Last Pumped ; for Temporary Holding Tank Permit (Y/N) To Building Foundation To Disposal Field To Stream, Pond, Lake, or Major Drainage Comments Page 1 of 2 72-026(11/84) ABSORPTION FIELD DATA Soils Rating in Absorption Strata 'Date Installed Width of Field Square Feet of Absorption Area Depression over Field (Y/~ Results of Last Adequacy Test Separation Distance from Absorption Field: To Water-Supply Well / t C~ To Building Foundation lot To Water Main/Service Line l c:~ ~..~ To Stream/Pond/Lake/or Major Drainage Course To Driveway, Parking Area; or Vehicle Storage Area Comments Type of System Design Length of Field Depth of Field Gravel Bed Thickness Standpipes Presen(~N) ~,...~ Date of Last Adequacy Test To Property Line To Existing or Abandoned System on ; On Adjoining Lots "~ o~ To Cu~tbank (if present) D. LIFT STATION Date Installed Size in Gallons "Pump On" Level at High Water Alarm Level at Tested for Electrical Codes (Y/N) Dimensions /~A Manhole/Access (Y/N) /^ "Pump Off" Level at //--,~ Vent (Y/N) Pumping Cycles during Adequacy Test. Meets MOA Comments ** Check Permitted Bedroom Rating Against HAA Request ** I certify that I have checked, verified, or conformed to all M CA and HAA guidelines in effect on the date of this inspection. Date MOA No. ~>'~-~--OL;) _.~ Signed Receipt No. Date of Payment Amount: $ Page 2 of 2 72-026 (11/84)