ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP171162 PID Number: 051-052-06
Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New ❑■ Upgrade
Name:
Preferred Custom Homes
ABSORPTION FIELD
❑■ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound
Address
148 E. Foxtail Cir, Wasilla, AK 99654
❑ Other
Phone
Number of Bedrooms
8NRating
Total depth from original grade
376-9136
3
GPD/SF
Ft.
LEGAL DESCRIPTION
Depth to pipe in a from original grade
Ft.
Gravel depth beneath pipe
Ft.
Subdivision Block Lot
Lake Hill Acres #1 6
Fill added above original grade
Ft:d__
Gravel length
Ft.
Township Range Section
Gravel width
Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION
DISTANCES
To
Septic
Absorption
Lift Station
Holding
Sewer
Total absorption area
Number of trenches
Dist. between..trenches
From
Tank
Field
Tank
Line
Ft'
_Ft.
\
Well
101.2'
80'
TANK XSeptic ElS.T.E.P. E] Holding [:]Other
Manufacturer
Greer
Capacity
11000 Gal.
Surface Water
>100'
\
Material
Number of compartments
Lot Line
9,8'
Steel
2
NA
Foundation
14.7'
LIFT STATION
Manufacturer
Capacity
Gal.
Curtain Drain
NAV"/
Remarks replacement only.
Septic tank
Pump on level at
in.
Pump off level at
in.
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
PIPE MATERIAL House to tank D3034 Tank to
drainfield D3034
Installer
Dakota Diggers
Drainfield CO/MT
Inspector Tyler Perron, AK Rim Engineering
BENCH MARK (Assumed elevation) 100 ft
Inspection1s' g/14/17
Location and description
dates: 2nd
3'd 4th
Concrete pad in front of garage.
COMMUNITY DEVELOPMENT DEPARTMENT APPROVALr,
OF A4 t1+rl
-.
Conditional Approval: Date
��'�P• '•:yPlot
00 :........... '*4�.
Z: ... :.j
......................
Mer L. Shreves .:.s
CE 9351
Approved CAri�cX Date
Inspection Report_9-1-12.doc
�S.
19,8719± -1%
8+ NAT'L
7 GAS
O~
BM 100'
WELL
SWING TIES:
A B C D
z4 2
00��
�ry EGPRP�E
O~
BM 100'
WELL
SWING TIES:
A B C D
C01
8.3 11.2
CO2
23.0371
CO3
24.1 35.7
STl
16.8 34.0
ST2
22.1 36.6
MT
56.2 46.4
WELL
35.0 52.8
WELL
REMOTE \ 1 30'
PETER STl \T I ST2 1,000—GAL SEPTIC TA
\ / S CO 1
` PROPpRM SFO
3,B
C
700' A
�- Y-
Ro,ecT��F
wF\
�q0
s� p p p ��s
\ 10' MIN. 10' MIN.
BM. GARAGE APRON, 100'
C01 LAPP D VENTS
CO2///� CO3
10 1 F.G. T 1
4' PVC
TO SEPTIC TANK
AT A SLOPE
OF 2%
Co.
w *:
wo
���, ;•
Ma I L. Shreves •� =
�j/cir�'•.•� CE 9351OPROFESSOIN
•� ����
# 1 11111 "
96.72'
SEPTIC
TANK
' CO3 (EXISTING
IOUBLE—SWEEP
LOT 6
I� APPROX.
17,000 s.f.
MT
(EXISTING)
REMOTE
METER
POLE
4'PVC BETWEEN SEPTIC TANK AND
WATERTIGHT COUPLERS CO MIN. SLOPE -2R
ON INLET AND OUTLET
OF SEPTIC TANK
SOIL
ABSORPTION
SYSTEM
(DUSTING)
moo- I
SEPTIC SYSTEM PROFILE
Conventional Single Family Residential
SEPTIC TANK REPLACEMENT AS BUILT
LEGAL
DESCRIPTION
LAKE HILL ACRES #1 LOT 6
Scaled as shown W0: 17-00392
ALASKA IUM ENGINEERING. INC. ° olAT 6/30/17 COMPL�TD 9/14/17
MUNICIPALITY OF ANCHORAGE
nt
On-Site Water&Wastewater Program Sr.
ate`; PO Box 196650 4700 Elmore Road
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax (907)343-7997 r r
http://www.muni.orglonsiteAli
„w
t)cpar tmcnt
INCH OR PG¢
On-Site Wastewater Disposal System Permit
Permit Number: OSP171162 Effective Date: 6/30/2017
Work Type: SepticTank Upgrade Expiration Date: 6/30/2018
Tax Code Number: 05105206000
Site Legal Address: LAKE HILL ACRES#1 LT 6 G:1561
Site Mailing Address: 24540 GRACE ST, Chugiak
Owner: PREFERRED CUSTOM HOMES OF Lot Size in Sq Ft: 17000
Design Engineer: ALASKA RIM ENGINEERING Total Bedrooms: 3
This permit is for the construction of:
❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: Date: ‘AC)//7
Issued By: pi L' e r 4 Date: 06/a 0 1 -7
MUNICIPALITY OF ANCHORAGE
Community Development Department
O
Phone: 907 343-7904
Development Services Division Fax: 907-343-7997
On-Site Water& Wastewater Program
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 051-052-06
Property owner(s) Preferred Custom Homes of AK, Inc. Day phone 355-7760
Mailing address 148 E. Foxtail Cir, Wasilla, AK 99654
Site address 24540 Grace Street, Chugiak
Legal description (Sub.d., Block & Lot) Lake Hill Acres #1, L6
Legal description (Township, Range & Section)
Lot Size 17,000 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(® all that apply)
Absorption Field LJ Initial Single Family (SF) U
(w/wo ADU)
Septic Tank Upgrade [X]
Duplex (D) [—J
Holding Tank ] Renewal ❑
Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
'14 / .
(Signature of property owner or authorized agent)
Permit/Rush Fees: o�I� ^ Waiver Fees:
Date of Payment: 41b-49It7 C.,k3C00CO Date of Payment:
Receipt Number: al-23 ,a-c 4- OWN-Receipt Number:
Permit No. (?t? i' ` ` D?% Waiver No.
Permit App_ - :
ALASKA RIM ENGINEERING,INC.
411 ENGINEERS—PLANNERS—SURVEYORS
9131 E.Frontage Road
A 1 Palmer,Alaska 99645
Telephone(907) 745-0222
Fax(907) 746-0222
Online at: www.alaskarim.com
June 27, 2017
Municipality of Anchorage, D.S.D.,
On-Site Water and Wastewater Department
4700 Elmore Road
Anchorage, AK 99519
Re: Lake Hill Acres#1 Lot 6
Septic Tank Replacement
ARE Project No. 1700392
The subject property is served by a private well and a septic system. There was a trailer on the lot that
was previously removed from the property. The owners intend to construct a new 3-bedroom single-
family dwelling. There is an existing garage building on the lot. Our firm conducted a septic adequacy
test on this septic system last year. The septic drainfield does not require replacement; however, the
septic tank is inside the 100 ft well setback and will be removed and replaced. This design narrative
addresses only the septic tank replacement. The design narrative is summarized as follows:
GENERAL SITE PLAN AND SEPARATIONS: All surrounding properties are served by private wells and
septic systems. See the attached site plan showing proximity to surrounding properties wells. There are
no surface waters within 100' of the proposed replacement septic tank. There are no wells within 100 feet
of the proposed replacement septic tank.
The MOA Onsite Documentation shows the original septic tank was installed 97 ft from the onsite well.
The replacement septic tank will be installed outside the 100 ft well protection radius (see attached,
Replacement Septic Tank Design drawing).
SEPTIC TANK DESIGN: The proposed septic tank will consist of a 1,000-gallon Anchorage Tank septic
tank (see attached, Anchorage Tank septic tank information). A benchmark was established on the
concrete apron of the existing garage building, elevation 100 ft. The IE's of the tank inlet and outlet are
shown on the drawing. These are established based on the elevation of 92 ft of the bottom of the existing
septic tank. The outlet line from the new septic tank will be connected to the existing sewerline to the
existing CO. The existing septic tank will be excavated and removed from the site.
The proposed septic tank will not adversely affect the surrounding properties. If you have any questions,
please contact me at 907-745-0222 or at marysalaskarim.com.
Sincerely,
ALASKA RIM ENGINEERING, INC. ``���\\\\IIIItI
�` OF AL i/
Mary L. Shreves, P.E. :QS,rr�I��
Senior Engineer
•
*i sTH )\ '*
Attachments: ""
• Septic Tank Replacement Design drawing
•
• Surrounding Wells drawing 1.1'„,•
. Mar 1 . Shreves
• Anchorage Tank septic tanks information sheet II�Q%rT•.•• CE 9351
hig/'i ROFESS\0e//1-7
;;����`_
/ ,%\l'.4 /
,s' \\ --.57C .
y / 19.8719± N � (�.
Y 8-1,4..43+ NAT'L \ 'V� \ /
GAS / \
rCV ,f? j $ '-'
' 0. .41' ") EX1ei1 E'N7' el isiG / 00'0 '
•� k.
� GPR �ry �O / REMOTE F�1 " = 30'
ti
r �� ?j9• q3' POLLSR -1 STALL NEW
____/ ,___ G 1,.•e-GAL SEPTIC TANK
Un Imo, \ �• PR�POSED�1' °BOUTS • 100' WELL SETBACK
PT1P. BM 100' / 5 co(EXISTING)
❑ REMOVE I ? CO(INSTALL FOR
P/P 0' WELL \ PpSEpc EXISTING I DOUBLE CO)
�p0 1i pRpBpR�' SEPTIC TANK
' „e,
3' LOT 6
700 \ I APPROX.
p 17,000 s.f.
\ Rp, .-o,
4-44
q o
4'6g;?O is 00 ONUS /G(ExIS nNG) o�` „,.\,
3\ REMOTE C3 el,1
'20'1,
\''• 0
-METER �~
�\ / POLE
WELL ❑
Elk_ LOT 7 / P/P w/`\ • _1(
10' MIN 10' MIN.
BM. GARAGE APRON. too'
rim CLEANOUT [CAPPED VENTS GEDPP
(PROPOSED)
(COSTING)
— r -LEVI L-r
J SOIL
)F / SEPTIC ABSORPTION
C6 23' TANK I.E. SYSTEM
fl; ( �) 06.00' (EXISTING) /
e PVC AT UNIFORM SLAPS. 92' //
MIN. SLOPE-2% (N. PER FT.)
MAX. SLOPE-A% (1' PER FT)
�. PVC AT UNIFORM SLOPE
INSTALL FINAL 10' OF e PNC WATERTIGHT COUPLERS BETWEEN SEPTIC TANK AND CO
PRIOR TO SEPTIC TANK AT A SLOPE ON INLET AND OUTLET MW. SLOPE-2)[ Q(' PER FOOT)
OF 2% Qi PER FOOT) OF SEPTIC TANK
SEPTIC SYSTEM PROFILE
vo,"".11I.�; Conventional Single Family Residential
��
�.<P``�`:�'"" A
' 4gS���i� SEPTIC TANK REPLACEMENT DESIGN
„.../g TH %� *�% RIPTIDN LAKE HILL ACRES #1 LOT 6
i P..). . It---??
.0 . Mary IU Shreves : �'
'/,•13>'••• CE 9351 ''moi .,_
jj fti , „ .•'*G __
',I'/ii-111r\\\���``7 Scaled as shown
` WO: 17-00392
)1�� l ALASKA RD! EAVINEERtn+c, INL”. n/AGTNF 6/30/17 COM O„TE
•
N
4/7 / \
/ 7 / /
\� /
G ,;!: '4r
\ -0 I 1" = 50'
\ IAT 6 %l• / /
vii,' ,,,.. \N ‹c-•"6.- .,. // / /
( 7193
/ t`) a - NAPE / \ s,?il / , \
/ / V (us
sk los/ il,... "4'--: .-- '`
/IP a'' 4 4 4.f / /
:.•
iOLF �r
• / g}1IC TANG
/ l" • 100•„11 g1BACK
/ np rte• �4�' __
I / o PSP NaL \ IATA
17.000 i 1.I 4- /
4,41:0.4,, s `S nr+ci '� Ak•
\ / 0
/ \ FELL a
\ LOT 7 / 17,;„74
ioo
444 444Zl's / 7
, , ,
\ /
/ /
i . /
��`,,,x illlConventional Single Family Residential
_��P,.s' . •••'.14,4,..,11//,,� SURROUNDING WELLS
C.•• J� ••• y /*r
/\ A :* i oEsauFna,
4:ii, LAKE HILL ACRES #1 LOT 6
• Mary 64 Shreves ••
''/cf>•• CE 9351 '
/ lii, 0FESS\0 P�`,� Scaled as shown WO: 17-00392
/� R N
11111\\\�\ANO/a7/1 1 AzAsxa RIM SAVINZIAMV. to ° 6/27/17 C0S tET
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264-4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
MA~L~G AODRESS
LEGAL DESCRIPTION
LOCATION
DISTANCE TO: ] /~O !
Manufacturer
Liq. capacity in gallons ]
·/00 C2 I~- HOMEMADE:
DISTANCE TO: We
Absorl~tion area ~:~ ! Dwelling
'
Materi~
Inside length_~__._~ I Width
Dwelling
DISTANCE TO:
No. of lines .
/
Length of_each line
Top of tile to finish gr~.~ ?
Length
Width
Material
Nearest lot line
Foundation._~. / ~ O /
Total length of lines Trench width
Material beneath tile
Depth
inches
PHONE ~NEW
6'2z/._ ?/ ~' ~_ [] UPGRADE
NO. OF BEDROOMS
PERMIT NO.
Liquid depth
PERMIT NO.
Liquid capacity in gallons
PERMIT NO.
Distance between lines
Total effective absorption area
PERMIT NO.
Type of crib Crib diameter Crib depth Total effective absorption area
WelJ Building foundation Nearest lot line
DISTANCE TO:
Distance to lot line PERMIT NO~
.~_e Absorption area(s)
Building foundation Sewe / Septic tank
DISTANCE TO: ~-o / /~0
OTHER
PIPE MATERIALS
SOIL TEST RATING
INSTALLER
REMARKS
DATE LEGAL
APPROVED
WATER WELL RECORD
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of Geological a Geophysical Surveys
Drilling Permit No,
LOCATION OF WELL (Please complete either la, lb or lc.) A.D.L. No.
~-~.leoroug, Suba,v,,,o. LOt Block I~.1 '/dqtrs. Section No. TownshiPNO Range EO Merldion
~e ~[
~ ~ ~ ~ -- of-- of--of -- S 0 wO
IC.~F~TANCE A~%-~FR~CTION FR6M ROAD mN~RS~CT'ONS ~. ow,[, o~ wE~: Ron Rowl~d
~d~.,,: 620 Jack. S%ree%
Street Address o,d Area of Well Location ~chorage, ~aska 99515
2. WEkL LOG Fee~ ~elow 4. WE~L DEPTH: ({inel) 5. DATE OF COMPLETION
Sur{ece
Material Type Top Bottom 176 ft. 9 - 6 -
B~o~ Loam S~d & G~vel 0 1~ e. Oco~m. ,Dom ~,o,or~ ~v.. ~ue
R~d & Gravel 15 ~0 OAuger ~deffed OBored ~Other:
S~d & Gravel & Bo~ders ~ ~ ~ ,.~.o. ~ .~o,o~e, ~ co.~..,oo,
~o.~der~ 60 80 ~ T.. W~., ~ O,h.~:
Bo~ders S~d & Gravel 80 100 e. CAS,Ne= ~ Th~eo~ ~
~n~ Q~ ~ravel ~n13~m ~00 ~/.~ diam. 6 in. to ~2 ft. Depth Weight ~ lbs./ft.
Sand & Gravel " 1~0 1~ diam.~in, to~ff. Depth Stickup~ft.
~ei S~d & Gravel 1~ ~2 9. FINISH OF WELL:
Waler Pea & ~?~e! ~ S~8 ~52 17~ ~y,,: ~?~ ~3~ m~t,~: ~"
Slot/Mesh Size: Length;
Set between fi. and ft.
Backfilling Gravel pack
,o. s~*~,c w*~, ~w~= ~52 ".
Dote
~ ~ Above or ~ Below land surface
Equipment used: ~,~ ~i~
I{. PUMPING LEVEL below land surface and YIELD
..... ~ ~N~O~ ~ ~ft. ~fter ~ hrs. pumping ~ g.p.m.
~[CIP~t ~ ~FPT. O~'~' ~t ~ ft. after ~hrs. pumping ~ g.p.m.
~ 4 ~ ~QZ Motedol: 0 Neat Cemen, 0 Other:
~J [ ~ I~' I3. PUMP: (if available) HP
~ ~ r Ct~l ~ ~ Length of Drop Pipe __ft. capacity
I~.,EUARKS: Tight Formation 14 ft.
Seapage Aqu~ier, Pea Gravel
I~. WATER WEhL CONTRACTOR'S CERTIFICATION:
15, Wefer Tempereture __~ ~ F ~ C
Bart Bullock's Well ~lg. Inc.
This well wes drilled under my jurisd[cHon end Ibis report is true to the bes~ of my k~owledge e~d belief;
$~t mn~.~,~ ~ell ~lg. Inc. ~
R~s~e~us~ness Nome '* '~troct License Number
Address: ~ ~ ~nv ~q/qWq L~..411~
/~ /~z e d Repres~hve
DEi:'AF;:'t"MEI'..!T OF HEAL.'i'H AND ENVIRONMENTAl_ PROTE:CTION
825 L STF~E:'ET, ANCHOF~AGE, AK 9950:i.
264.-/.I. 720 .
PEF?MI T' lq():
DATE ISSUED:
84()796 HAND WR ]; 'I"TEN
09 / 19/84
APPL, I CAN]":
ADDRESS:
CONTACT PHONE:
RON F'.:OWLAND
620 JACK STREIE]"
ANCHORAGE, Al< 99515
694-.9192
LEGAL. DESCIRIP~
LOT SIZE:
t_OT L. OCAT ION:
SLIBD ]: V I !.-.310i'-,!: I_AKEH I t._L AC)RES :I~ 1
SECT~ION: 3 TOWNSHIP: 15N
17000 (SF2.FT,, OR ACRIES)
GRACE ROAD
L. OT:' 6 BL.OCI<: NA
RAIqGIE: IW
cert. i {y t. hat:
:I.. I am familiar ,/~i'Lh the requir'en'~(.z.~n't:.s fop on-site sewers and we].!s as
_ """ .... I ' '~ ' ' F
~,t~,...,, and t. h0:.~ State of Alaska
For'th by 'f he M..uq J c.I P ~:,.. ] ~ ¥ c] AI"lchc)rage ¢'¢¢'~' *
2'.. I .(.~:i. I 1 insCa]. 1 the sy~d:.em :Ln ac:c~:~rdal-~Ce ,~w:Lth aI ! MOA (::od(.2s arid r'egulat.:i, orHs~
and in mc:)mpl~ar~c:e wi:Ch t. he design (:r'J. CePia c)f this per'mit.,
3, I ~]J.I]. adhere Lc~ all IdOh anti State of Alaska r, equ:LremerrtLt~ fern i:..he ~et ba~k
c:tist, an~es fr'c)m any ex2s.t, ing v.~eZZ, ~A, aste~.,,~at, er' d:i. sposa], syst. em c:)r' public:
s~Nv~,:.?ra~je syst. e)m mn t. his of" any adjac:eJht cH" r'iear'by ].(:)'~.~
IF: A I_!I'--T S"FA'TION IS INS]'F~I..I....ED IN AN AREA COVE:RED BY MOA BUlL. DING CODES,
TFIEiq (1) AN EL~ECTIRICAL PI:T. FRMIT AND ]:NSF'ECTtON MUST BE OBTAIN[I); (2) AS.-BUIL.TS
t/~ILI_ NOT BE AI:'F'ROVED WITHOLJT AN ELIECTRICAL INSF'ECTION R1EF'ORT~ AND C3) THE
IEI_.IECTF~]:CA!_ WORK t'fiUST BE DONE BY A L. ICENSED EL..ECTRICIAN,
S I GNED
APF'I_ICANT: RON ROWLAND
DATE:
ISSUED BY DATE:
~-~,MUNICIPALITY OF ANCHORAGE-~
Departmen' )f Health and Environment. "~Protection ~
Permit ~
Applicant: ~ O ~J
825 L Street, Anchorage, AK. 99501
264-4720 /~, '
* * *
q HANDWRITTEN PERMIT * * *
~.DWELL ,AND/~ ON-SITE SEWER PERMIT
~ LA ~ ~ Mailing Address: 62 CP ~..~,~(~-(]gJ~.k~ ~'-~'
Location: ~ '~ Phone Number:.
Legal Description: ~ ? /,m~ ~_', ~/-~Lot Size: /"7/
Type of Soil ~sorption System Is:
Trench; Drainfield: /Seepage Bed: Holding Tank:
Maximum N~ber of Bedrooms: ~ '-- Soil Rating(sq.ft/br) /~
DEPTH
The Required Size of the Soil Absorption System Is: ~
LENGTH ,~3 . GRAVEL DEPTH '~' WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the ~xcavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
REQUIRED SEPTIC(HOLDING) TANK SIZE : /~)O<C~ GALLONS
*
*
*
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve° ~
* * * TWO(2) INSPECTIONS ARE~.REQUIRED
Backfilling of any system without final inspection and approval by this departmen
will be subject to prosecution. ' '
Minimum distance between a well and any on-site sewage disposal system is 100 fee
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other-requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31, 1 9 * *
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
to include more that 3~bedrooms.
Tssued by: ~_~~ ~~--~
Date:
the residence is remox~eled
S igne~: ~~~~
Applicant
SWP/024(i/81)
PERFORMED FOR:
LEGAL DESCRIPTION:
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
825 L, Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
SOILS LOG
PERCOLATION
TEST
1
2
3
4
5
7
8
9
10
11
12
13
14
15
16
17,
18-
20-
2225-E
1971
SLOPE
· I
I I IIII
,,
SITE PLAN
ENCOUNTERED?
O
P
E
IF YES, AT WHAT
DEPTH?
Gross Net Depth to Net
Reading Date Time Time Water Drop
/
u,' .~ f~ ~.,,~,/
PER-GO L-A"T"f~f~ R AT E
(minutes/inch)
TEST RUN BETWEEN FT AND
PERFORMED BY: ~~ CERTIFIED BY: ~ ~
MUNICIPALITY
7 1
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 051-052-06 Expiration Date: 2
1. GENERAL INFORMATION
Complete legal description LAKE HILL ACRES #1 LOT 6
Location (site address) 24546 GRACE STREET, CHUGIAK, AK 99567
Current property owner(s) AMANDA & ALEXANDER WOODELL Day phone
Mailing address
Real estate agent
24546 GRACE STREET, CHUGIAK, AK 99567
2. TYPE OF DWELLING:
® Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
Day phone
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Private Well
®
Private Septic
Water Storage
❑
Holding Tank
❑
Community Well
❑
Community
❑
Public Water System
❑
Public Sewer
❑
Waiver request for: Distance:
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ -6-�d Waiver Fee $
Date of Payment 5--6o— 2.621 Date of Payment
Receipt Number Receipt Number
COSA # SSG 22 >' 7 Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed heretoandas of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater
disposal system is (are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in
effect at the time of installation. I acknowledge that On -Site staff may visit the site to verify the information submitted.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Address 13030 SUES WAY, ANCHORAGE, AK 99516
Engineer's Printed Name CURTIS HUFFMAN, PE Date 5/5/2022
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system The
and maintenance. operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
,r •
g�Q: • • • • • �9 ��
.
discrepancies exist can be given by First Water Consulting &
*: � TH •.*
F wrs
6. DSD SIGNATURE
Curtis Huffman
����<`c�s•,_
XSystem #1 Approved for bedrooms
CE 128991 •. ��'
�l>,FoPROFES
System #2 Approved for bedrooms
S NP\� �
Disapproved
plConditional approval for bedrooms,
with the following stipulations:
L nn "Jv -
b� o6l I ,YGIr$.� c2 C4 e•R./,�tj,:0,P
lo
jZ ON-SITE
WATER AND
J ,L
PROGRAM
—z
O 1
By: '�-• �✓ Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the
representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is
not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
-Legal Description: LAKE HILL ACRES #1 LOT 6 - Parcel ID: 051-052-06
If more than 1 septic system on lot: COSA Checklist # _of _ Structure served by this system
A. WELL DATA
® Well log is filed with Onsite (or attached)
Date drilled 9/6/1984
Total depth 176 ft
Cased to 172 ft
® Sanitary seal is functioning correctly
® Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 5/3/2022
Static water level at beginning of test 163 ft.
Comments
B. TANK DATA
Age of tank(s) 5 years
Tank type/material SEPTIC / STEEL
Measured operating fluid level in septic tank 50"
® Standpipes/foundation cleanout per record drawing
Date of pumping 5/2/22
D. ABSORPTION FIELD DATA
Which system tested (date installed) 9/13/1984
® ALL standpipes present per record drawing
Total measured depth from grade 7_7 ft (max)
Measured depth to pipe invert from grade 6.3 ft (min)
❑ N/A — pressurized field
Well production at time of test 5+ gpm
Water storage tank volume NA gallons
Well disinfected for coliform test? ❑ Yes ® No
® Coliform bacteria is Negative
Nitrate 0.89 mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ® Arsenic less than MRL (ND)
Collected by NES
Date of Sample 5/6/22
C. LIFT STATION
❑ Required maintenance completed
Age of lift station _ years
Lift station material
••uu-I
Adequacy test date 5/3/22
Results M Pass For 3 bedrooms
Fluid depth prior to test 18 in
Water added 520 gal
New depth 24 in (NO BACKING INTO ST WAS VIS.)
❑ Monitor tubes go to bottom of effective. If not, state Elapsed time 18 min
depth into effective IR 3' ED SHOTS = 2'ED APPROX.
® Code -required soil cover over field Final fluid depth 1330 in
❑ System presoaked Absorption rate 450 gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) N
date of test)
Gallons introduced gallons If yes, enter date
Comments/Deficiencies: MT / CO AT GRADE. APPEARS FIELD IS OPERATING IN THE TOP 0.5' ED OF THE MOA IR 3'ED.
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well)
® Yes
Septic Tank/Lift Station on Lot > 100'
ft
Surface Water > 100' ® Yes if No _
Community Sewer Manhole/Cleanout > 100'
® Yes
if No
ft
® Yes
if No
Neighboring Tank > 100' ® Yes
if No
ft
Private Sewer/Septic Line > 25' ® Yes
if No
Absorption Field on Lot > 100' ® Yes
if No
ft
Holding Tank > 100' ® Yes
if No
Neighboring Absorption Fields > 100'
if No
ft
Animal Containment > 50' Yes
if No
® Yes
if No
ft
Manure/Animal Excreta Storage > 100'
Community Sewer Main > 75' ® Yes
if No
ft
® Yes
if No
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
® Yes
if No
ft
Surface Water > 100' ® Yes if No _
Property Line > 5'
® Yes
if No
ft
Wells on Adjacent Lots:
Absorption Field > 5'
® Yes
if No
ft
Private Wells > 100' ® Yes if No _
Water Main > 10' .
Yes.
if No
ft
Community Wells> 200' QI Yes if No _
Water Service Line > 10'
® Yes
if No
ft
If septic tank is under driveway comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
® Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
® Yes
if No
_ ft
Wells on Adjacent Lots:
Water Main > 10'
® Yes
if No
ft
Private Wells > 100' ® Yes if No _ ft
Water Service Line > 10'
® Yes
if No
ft
Community Wells > 200' ® Yes if No
Surface Water > 100'
® Yes
if No
ft
F. ENGINEER'S COMMENTS
G. ENGINEER'S CERTIFICATION
l certify that l have determined through field inspections and review
of Municipal records that the above systems are in conformance
with MOA COSA guidelines in effect on this date.
TM
r Curtis Huffman
��� �F� •. CE 128991
Ri?FESSONA����
ft
ft
ft
ft
ft
ft
ft
ft
6 '78910
CD
\A . 77,
t 10 e..e.n..:''. 2 r3'
Mu 1 icipality of Anchorage =
On Site Water and Wastewater Program ��•;=:•R
(907) 343-7904
4. ti
c Cu
zi
Certificate of On-Site Systems Approval of 6 8 L g'
Parcel I.D. 051-052-06 Expiration Date: I O' I Z•- '- I U
1. GENERAL INFORMATION
Complete legal description Lake Hill Acres #1 L6
Location (site address) 24540 Grace St. Chugiak, AK 99567
Current Property owner(s) Preferred Custom Homes of AK, Inc. Day phone 907-376-9136
Mailing address 148 E. Foxtail Cir. Wasilla, AK 99654
Real Estate Agent N/A Day phone
2. TYPE OF DWELLING:
E Single Family (w/wo ADU)
Duplex
n Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 0 Individual 0
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: ' ,u,-dAZe �-> 2,-c► ,,-,5,-e Date: 7//.3// Sr
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ 5 2 Waiver Fee $
Date of Payment 1017141 t Date of Payment
Receipt Number It 2.2 (01,036 Receipt Number
COSA# n b( igi6,0 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Alaska Rim Engineering, Inc. Phone 907-745-0222
Address 9131 E. Frontage Rd. Palmer, AK 99645
Engineer's Printed Name Norman K. Gutcher Date 6/26/2018
OF ` ee
•® =49TH
6. DSD SIGNATURE el • •0"••••O°°0•° °•
2(, System#1 Approved for (3 bedrooms ® '°' �
/
tP cc, Normal uZcher
System #2 Approved for bedrooms ¢4 -,:sem;
° CE-4919 ° j
Disapproved 4 e�pROFESS\°Ns5'
Conditional approval for bedrooms, with the following stipulations:
v OF HlYi,jy` .
ON-SVt Np
� WA1ER zRJ.oT W PSCC RpROG
tl,:
„n- r .,.
r
(Z7cCaq Original Certificate Date: 7--
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet j '.<
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Certificate of On-Site Systems Approval Checklist
Legal Description: Lake Hills Acres #1 L6 Parcel ID:051-052-06
A. WELL DATA
Well type Private If A, B, or C provide PWSID# NA Well Log (YIN) Y
Date completed 916184 Sanitary seal (YIN) Y Wires properly protected (Y/N) Y
Total depth 176 ft. Cased to 172 ft. Casing height(above ground) 12+ in.
FROM WELL LOG AT INSPECTION
Date of test 9/6/84 6/13/2018
Static water level 152 ft163.6 ft.
Well production 14 g.p.m. 5.5 g.p.m.
WATER SAMPLE RESULTS:
Coliform A colonies/100 mL Nitrate 0.466 mg/L
Arsenic MRL ug/L Date of sample: 6/14/18 Collected by: Brandon Jones
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/ Steel Greer Date installed 9/14/2017
Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N
Date of pumping NEW Pumper
C. ABSORPTION FIELD DATA
Date installed 9/13/84 Soil rating (g.p.d./ft2 or ft2/bdrm) 150 System type 5' wide
Length 53 ft. Width 5 ft. Gravel below pipe 3 ft.
Total depth 7.3 ft. Eff. absorption area 456 ft2 Monitoring tube Y Depression over field N
Date of adequacy test 6/13/2018 Results(Pass/Fail) Pass For 3 bedrooms
Fluid depth in absorption field before test 14 in. Water added 636 gal. New depth 16 in.
Elapsed Time: 102 min. Final fluid depth 14 in. Absorption rate >= 636 g.p.d.
Any rejuvenation treatment(past 12 mo.) (Y/N &type) None Known If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on"level at in. "Pump off' level at in. High water alarm level at in.
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot 1001+ On adjacent lots 100 +
Absorption field on lot 100 + On adjacent lots 100'+
Public sewer main NA Public sewer manhole/cleanout NA
Sewer/septic service line 25'+ Holding tank NA
Animal containment areas 501+ Manure/animal excrete storage areas 100 +
SEPTIC/HOLDING TANK ON LOT TO:
1+ + 5'+
Building foundation Property line Absorption field
Water main NA Water service line 101+ Surface water 100'+
Wells on adjacent lots 1001+
ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 101+ Water main NA
Water Service line 101+ Surface water 1001+ Driveway, parking/vehicle storage 101+
Curtain drain None Known Wells on adjacent lots 1001+
F. COMMENTS
2000 Gallon Pre-Soak was performed.
G. ENGINEER'S CERTIFICATION ��r OF A� ���A
•c RaOCy
I certify that / have determined through field inspections and ����' x,"°• °�,'w �
review of Municipal records that the above systems are in a'' `* . ��
conformance with MOA COSA guidelines in effect on this date. 4 rr••;y ?3 ,,-; ^V.w
p,°r7,.. ....o.2on C.1.ao- sa•a:.•.) a J
Engineers Printed Name Norman K. Gutcher c�P i/ ryc,��� � a¢
6/26/20181 Skoc3.cr, r..Gira"_:.1er 4..;
Date -,‘?4.;:: '%.='= _ �'r
jX.\%(:+/);,w i... •—•.-:';`:..,: .'Y"P
COSA canary sheet_2-6-15.doc
UTILITY
,., ,111°kid" k PEDESTAL MILLER RD.
12. N31'22 30"E 100.00'(R&C) u o
0 — ;i
POWER N
POLE (TYP.)
23'± _
„ 32.2' re)
o WELL 4 GARAGE `''
0 NAT. I
32.2' GAS
�'''—U.G. T
GRAVEL DRIVEWAY
(A ca _ o-
cs) .y. (t1 to 0DECK (17P.)o ».s' b
0.�w oa CANT— 2o.0. 2.0'.s' _ 21'f _ o
o
V3 -t -n c o owl,
O? O cv ^J(s LU
W03 ul U` 21't O� _0, ' 2.0'
Wcc; ro
cv
w. ii bro 129' 1g.3' NAT. co
GAS (n I•< ri
00 U.G. T&E
.--i „
c_
C\2 N-1 0N
J,
`� LOT 6
4" PLASTIC
OH O H0 „ PIPE (TYP.) I
i 1-1
- OFF LOT FENCE
w
ANCHOR
.
531'22'30"W 100.00'(R&C)
25'
Q U I
RECOVERED 5/8" 4. METER POLE ) ----LIGHT POLE
REBAR (TYP.)
LEGEND: o
(C)=CALCULATED DATA to
(M)=MEASURED DATA
(R)=RECORD DATA PER PLAT
ohu=OVERHEAD UTILITIES — — — —
U.G.=UNDER GROUND
T&E=TELECOM MUNICATION & OLD GLENN IIWY.
ELECTRIC
NAT.=NATURAL
(TYP.)=TYPICAL
NOTES:
1. EXCEPTING FOR GROSS NEGLIGENCE, THE LIABILITY FOR THIS SURVEY SHALL NOT EXCEED THE COST OF PREPARING THIS SURVEY.
2. THIS SURVEY REPRESENTS VISIBLE IMPROVEMENTS & CONDITIONS ON THE DATE OF SURVEY.
3. THIS DOCUMENT DOES NOT CONSTITUTE A BOUNDARY SURVEY & IS SUBJECT TO ANY INACCURACIES THAT A SUBSEQUENT
BOUNDARY SURVEY MAY DISCLOSE.
4. THIS SURVEY PERFORMED FOR PREFERRED CUSTOM HOMES, IT SHOULD ONLY BE USED FOR A SINGLE PROPERTY TRANSACTION.
REUSE OF THIS DRAWING FOR ANY PURPOSE NOT STATED ABOVE WITHOUT THE EXPRESS WRITTEN CONSENT OF ALASKA RIM
ENGINEERING, INC. IS A VIOLATION OF FEDERAL COPYRIGHT LAW.
EXCLUSION NOTE: IT IS THE RESPONSIBILITY OF THE OWNER TO DETERMINE THE EXISTENCE OF ANY EASEMENTS, COVENANTS, OR
RESTRICTIONS WHICH DO NOT APPEAR ON THE RECORDED SUBDIVISION PLAT. UNDER NO CIRCUMSTANCES SHOULD ANY DATA HEREON
BE USED FOR CONSTRUCTION OR FOR ESTABLISHING BOUNDARY OR FENCE LINES.
SURVEYED BY: FARMER SURVEYING LLC. MAILING ADDRESS: 6183 N. STEEN RD. WASILLA, ALASKA 99654. OFFICE: 9131 E. FRONTAGE
RD. SUITE #20, PALMER, ALASKA 99645. PHONE: (907) 355-0620 EMAIL BCFARMER®MTAONLINE.NET
18-33FSLLC UNDER CONTRACT TO: ALASKA RIM ENGINEERING INC.
,`„"„11 KA ALASKA RIM ENGINEERING, INC.
` s�
OF sel��� AS—BUILT 9131 E. FRONTAGE RD.
� ' k'.•.. F;....
........
•••°•A•"r4- I,'g i Wesel P. PH: (907)745-0222 ER, L: SKA FAX:99645
(907)746-0222
S' •.9 EMAIL: akrim®alaskarim.com : WEB: www.alaskarim.com
5*149TH I\ •,, i , 1;1'
• WO: 1700392
.. ... ....°°°°°°.....o..°� FB: 18-02
;J- �� _ Z PAGE: 1 of 1
i'O • e 4 ...
Engineers: Planners: Surveyors SCALE: 1 " = 30' FILE: 1700392AS
v� .Robert J. Farmer ,o
'-';';'• _ I HEREBY CERTIFY THAT A MORTGAGE INSPECTION WAS PERFORMED
10615—S °;° _�
c.
UNDER MY
I�I�•pROFESsiaw.*,_0\ �``` LAKE HILL ACRES TISUBDIVISION ON ON THE F#1, LOT N6, PLAT G RNo.D64R 90ERTY:
1��° tSSI $ ,7 ANCHORAGE RECORDING DISTRICT, ANCHORAGE, ALASKA. �2o1a
SURVEYED ON THE 27th OF FEBRUARY, 2018.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water ~nd Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
wWW.ci.anchorage.ak, us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
o
GENERAL INFORMATION
complete legal description
t_oqation (site address or directions)
Current Property owner(s)
,~aiiing address
Lending agency
Mailing address
HAA*
Expiration Date:
Day phone
Re~t Estate Agent
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
NUMBER OF BEDROOMS:
TYI~E OF WATER SUPPLY:
Individual Well
individual Water Storage
Community Class ~
PUblic Water System
Welt []
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 4 by an independent professional civil
enginee~ registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. CeKificates of Health Authority Approval are
valid for 90 days from the date of issue for prope~ies served by a private or C~ass C well and may be ~eissued with
new water samp!e results. (Certificates may be reissued for s period of up to one year with valid water samples.)
Certificates are valid for one year for properties served by Class A or B wells or a public water system. The
Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
STATEMENT OF INSPECTION BY ENGINEER ~
As certified by my seal affixed hereto and as of the validation dateI shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the ch-
site water supply and/or wastewater disposal system is(aro) safe, ifunctional and adequate for the number of
bedrooms and type of structure indicated herein. I further verify thatl based on the information obtained from the
Municipality of Anchorage files and from my investigation and iaspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and Slate codes, ordinances,
and regulations in effect at the time
Name of Firm /~,,
Engineer's Printed Name
DSD SIGNATURE
/~ Approved for 3
Disapproved.
Conditional approval for
Phone
bedrooms.
bedrooms, with [he following stiouiations:
Additional Comments
Attachments:
HAA Checklist X
Septic System Advisory
Well Ftow Advisory
By: .... ~ ¢ ~
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date://'~.~/~,~
(Rev. 01/o2)
Legal De~sCfip~ion,:
A. 'WELL DA.T~,'"
HEALTH:i:AUTFiO RI~':AP..PROVAI~ CHECKLIST'
.~:::.~?, .... L..;.,..:.~.. ~..~.: ~. ::' .7';.!.~..: ,......:....'.:.:' ...'.'.i'".' "
.... ..
'I[A~. B ~'.o~ Gi,'p~ovide"PWSiD,~t -- Welt Log O'/N):
....... · :.'?.;'.".'i~i~..'.''. .... .' .'.=. :.' .' ...:..i:,"...:;'..
wires, pr~...e..r~y :' pfote~t,e~:i~!N.)'
CaSing be~b~(:above.ground:). ']:~ '. in.
AT INS'R. EGTION.
4'h,+-/:~'~. , .g!:p.m.
F0dndatier~ .'( ove'~ :tank. ~/N)' .../~'o. ·.
'C
Otl~..,e.r:bacted~'~ cb!or~ieSL~100 mi.
- Cleanouts'(¥1N) ~.~'$'.,
High water alaCm. (Y/N). '4/:~
Date o~:ad¢~ua.qy:tes, i,'t~[:t~..~>z.-. :., ;.:i"' R~l't~:'(,-.Pass/F~il)::.'-'¢~' For ,~:': :bedroems
Fluid:depth in..absoCpii~..fi~t~'befamtest:.-/~i':': :in.';.{.i ' , ' water.add;ed~;4~!.ga!. New.deptfi'z~ '.in.
ElapSed.~Time:" .O~..'' .'min.: F.[na'l'fluid. depth....'~'~'i' in. '.Absorption. rate '>'= -'~':~ g:p:d.
Any rejuvena[iOn:,treatmen't (pa~(':ii2'mo.)?(YIN 8; type) 'if yes..a ve date
Date installed Size in gallons, " MarJhole/Access (Y/N)
"Pump on" level at in. "Pump. o~':.level at..? in." .: High Water:.alarm leve at
Datum Cycles tested Meets .alarm & circuit requirements?
SEPARATION DISTANCES
SEPARATION DISTANCES FROM 'WELL ON LOT .TO:
Septic tank/lift.station' on 10t 0[~'~
· On adj'~Ceflt
On adjacent lots
Absorption field on lot ,~<:~ '
Public-sew&r.main. .fi~. w- Public'sewer marihote/cleanout
Sewef/~ptic s'ervi(~e line '~-~ ~ -"Holding tank
SEPARATi'~N'"DISTANCES'FRO'M 'SEPTICTHOLDING TANK':0N.:'L~3T TO:
Building foundation II:'f~ Property line ['~-{' Absorption' field
Water main ~N.[. "" t-'~"."Water service line.',~ ~ ..... Surfa";e.'~ater
Wells on adjacent lots ;~. toc, '-
SEPARATION DISTANCE FR'OM:AB~RPTION FIELD ON LOT TO:" -' · -
· Building foundation
Surface water
We s on.adlace6~ ~.~'.
Properly line
Water Service ne"
COMMENTS
ENGINEER'S cERTIFICATION`
I certify tha~':/, have determined through'fie/d inspections 'and'
review of Municipa/.records that, the above, s,Y~ernS' are4n,, '
conforma~iee with 'MOA"HAA'~/~iagi~e~ in'e~f~"~h'thT§'~g~b".. -
Eng,neeCs Printed Nsme ~.', ~:: ~
Date' of Payment
Receipt Number
(Rev. 12/01 )
Water main
D~iveway, par~ihg/vehicle'storag&' '" '"~"~
Receipt Nember
liat-Su Test Lab of Alaska
Mile 3.2 Palmer-Wasilla Hwy.
Midtown Community Business Park
P.O. Box 2749
Palmer, Alaska 99646
Phone: 745-3005 Fax: 746-3010
Membrane Filter Analysis
Coliform Bacteria
Client: Alaska Rim Engineering, Inc.
Address: P.O. Box 2749
Palmer, Ak: 99645
PhOne #: Fax #:
PWSlD#(if applicable):
This Section to be Comoleted by Saml~ler
Legal Description of Property: Lake Hills Acres #t Lot 6
Sample Site Location:Kitchen Sink Delivered to Lab By:C. Leet
(I.E.: kitchen sink, bathroom sink~ outside hose bib)
Time Sampled: 1700 Date Sampled: 1/19/03 Sampled by:C. Leet
Sample Type: Routine:r-~ Treated:[-'] Untreated:r-] Repeat Sample #:
Analysis Results:
[] Satisfactory
[]* unsatisfactory
This Section to Be Com~31eted bv Lab
r-i, Sample Rejected: [] Over 48 Hours in Transit
[] Confluent Growth
[] TNTC: Colonies too numerous to count,
*RECOMEND RESAMPLE WIITHIN 24 HOURS
Final Membrane Filter Results: 4! Total Coliform Colonies/100 mi
~1 Other Bacteria {Maximum = te0Co~n~s/lO0 mi)
4 t Fecal Coloniestl00 mi
Date Analysis Completed: !/A ~/~, Reported By: (~/
Microbiology Laboratory Record,Coliform Analysis
Date Received: ~Time Received: ~J3~ Lab Number: ~o~ ~f~J
Date Test Started: ~/~ Time Test Started: /,~
Test Results Test Method
Direct Count: /~
Membrane Filter
Color: Sheen:
Tube #:
Presumptive (LTB) 24 Hr.
48 Hr.
24 Hr.
Confirmatory (BGB) 48 Hr.
Tube #:
Fecal (EC) 24 Hr.
Colonies/100ml
Red: Pink:
Received by:
Analyst: ~.~ ~'
Date/Time/Analyst
U ? D
/
P, EBA
7975
GA $ /
CO,'VC.
TEL E.
REMOTE
POLE
SEP TIC
LOT 6
DECK ~,/ APPROX.
SfAIR5 TRAILER 17.000
TYP. ~ AOO-ON$
N~ T'L
On-Site Water and Wastewater Program
4700 Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
ww~v.ci.anchorage.ak.us
(907) 343-7904
Waiver Review Worksheet
WR#: WR030002 PID~: 051-052-06 HNk HA030020
Date Received: 1113103
Legal Description: Lake Hill Acres #1 Lot6
Engineer Charles Leet. PE
Alaska Rim Enaineerinq
Applicant: Linda Manle¥
Permit:
Waiver Requested: 97' from well to septic tank
Criteria: GeOlogy
A. Water Table
B; Soil Sorption
C. Permeabili~
D. Water TableGradient
E. Horizontal Separation
Total:
Points:
Waiver is not OMn~
List Conditions or Reasons ~rabove: ~'L~' ~'-~-v/-//~"~~)
Name of Reviewer
Rec#: 030033 Amount: $800.00 DatePaid: 01/13/03
George P. lVuerch,
Mayor
Municipality of Anchorage
Building SafeD Division
Anchorage
Ali-America City
2002
1/23/2003
Charles A. Leet, PE
Alaska Rim Engineering, Inc.
P.O. Box 2749
Palmer, Alaska 99645
Subject:
Waiver Request for Lake Hill Acres #1 Lot 6
Wajiver Request #WR030002
Parcel ID #051-052-06
Health Authority Approval Number HA030020
Dear Mr. Leet:
Your request for a waiver of the required 100 feet horizontal separation from the
septic tank to private well has been approved. The approved separation distance is 95.0
feet.
This waiver approval applies to the existing septic tank to private well separation only.
Any future upgrade to the on-site wastewater disposal system will require all separation
distances be met or another approval from this department.
If there are any further concerns or questions regarding this waiver, please call our office
at 343-7904.
Sincerely,
Daniel J. Roth
Civil Engineer'
On-Site Water & Wastewater Program
P.O. Box 196650 · )mchoragc, Alaska 99519-6650 ·Tclcphon¢: (907) $43-8501 · Fax: (907) 848-8200
4700 South Bragaw Strcct ~ Aztchoragc, Alaska 99507
It ttp://wxxav.ci.anchorag¢, ak.us
-WELL
'~=.ZS"I- 7.~
6. R.O.
7.3
· ,',", orlo~/
2.¢
2.0
(~£L USI ol~
Phone (907) 745-0222
Fax (907) 746-0222
akrim @ rogershsa.com
lanuary 3, 2003
P.O. Box 2749
Palmer, Alaska 99645
Dan Roth, P.E.
Municipality of Anchorage
Development Service Department
P.O. Box 196650
Anchorage, AK 99519
RE: Lot 6, Lake Hill Acres, Addition # 1
Subject: Waiver Request
Dear Mr. Roth:
In December of 2002 our firm prepared an as-built survey of the referenced lot. Based on the enclosed as built, the
septic tank and onsite well separation distance appears to be 97'.
In December of 2002 our firm performed an adequacy test and the system seems to function correctly for a three-
bedroom dwelling. The system was installed in 1984 and was approved by the Municipality at that time. In addition,
the septic tank does not appear to be leaking.
The well log for the onsite well indicates a cased well to a depth of 172', with a 152'static water level. On 12/16/02
the static water level was measured 162'. The well produced a steady 5.2 gpm with very little draw down. Well logs
from neighboring lots were not available on-line and most likely no documentation exists. On Lot 7, another
engineering firm measured the static water level to be 152' in 1987, which is consistent with static water level on the
Lot 6. In 1987 the neighboring Lot 7 received a separation distance waiver for their onsite well and septic system
for 70'.
The surface topography slopes away from the well to the east and northeast such that any seepage would be directed
away from the well. The subsurface soil were rated as SP type with an application rate of 150 sq.fk/br. The well is
located opposite of the house from the septic tank.
Water samples were collected on 12/16/02 and 1/2/03 and tested by others for total coliform bacteria and nitrates
and found to be satisfactory. Enclosed is a copy of the test results. The lesser separation distance between the septic
tank and onsite well doesn't appear to having an adverse effect on the water system.
If you have any questions or wish to discuss this matter further, please contact me.
Sincerely,
A~k, ~ a .Rim Engineering, In~.
Professional Engineer
Encl: Review Fee
HI-IA Check List & Certificate
As-built
Water Test Results
cc: AK Rim File #02-1126
Engineers · Planners · Surveyors
WATER WELL RECORD
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of Geological ~ Geophysical Surveys
LOCATION OF WELL (Please complete either lu~ ib or lc.)
so.O.oh Lo, I.D.
~ch ~ ~es 6
B~n Lo~m S~md & Gravel
2.nd & Gravel
Sand & Gravel & Bo~ders
~m,~ ~ers ...
Boulde~ S~d &/~ravel
~ ~d Gravel
~8 $ Gravel -
Wet S~d'& Gravel
Water Pea & ~mv~ & S~d
Feet Below
Surface
Top Bottom
o ~5
15 40
80 100
100 1%0
140 160
1~') 162
162 1'76
Drilling Permit No.
A.D.L. NO.
Section N~.1 Township N[~ Range. Er-] Meridian
sE] wE]
~. OWNER OF WELL: Ran Rowland
A~r.l,: 620 Ja~.. St~et
. ~o~ge, ~as~ 99515
~ Irrigation
~ Tell Well ~ Other:
~. CASING: ~ Threaded
~,.. 6 ~.. ~ 172 ..o.,,h w.nvh~ 1~ ,b../..
Typo: ~p~n T"tO'7 ~' Diameter:
STATIC WATER LEVEL= 152 f,.
[~ Above or ~ ~low land ,urface
Equipment used: ~nt~ ~t~
PUMPING LEVEL below land surface and YIELD
fi. offer 3 hrs. pumping 1.~ g.p.m.
ff. after . hrs. pamping g,p.m.
IE.GROUTINO Well Srouled: [::] Yes
Material: ~ Neat Cement ~ Other:
15. PUMP: (if available)
,...E~A..a: Tigh% Faction 14 ft.
Seepage Aqu~ier, Pea Gravel
16. WATER WELL CONTRACTOR'S CERTIFICATION.*
Bart Bullock's Well ~lg.. Inc.
Addr..:. ~.~,Box ~87427~I Waoilla
LEGAl.
PERMIT NUMBER-
From
From
From
" EAGLE RivER ENGINEERING SERVICES
I..u E=~e~a, PJg.
P.O. Bo~ 773294
Eagle River, Alaska 99577
Te]ephono [007) ~04-~19~
June 4, 1987
Mr. Steve Morris
Civil Engineer, On-site Services
Municipality of Anchorage
P.O. Box 196650
Anchorage, AK 99519
I%Y O~ ANcHO~AG~
JUN 9 1987
REF: Lake Hill Acres #2, Lot 7
Dear Mr. Morris:
Attached, please find information 'necessary for your
determination of a waiver of seperation distance, private well to
septic leachfield to 80,' and well to septic tank 70'.
The septic system, absorption rate has been tested and found
adequate for 2 bedroom use. The leachfield was installed in 1970 and
was inspected and approved by the Municipality at that time, as per
the inspection report enclosed. The existing septic tank is located
48' from the well and will be replaced by a new tank at 70' distance
from the well. Our field measurements confirm the leach pit edge to
be at 80' from the well.
There is no well log for the on-si~e well, but our testing has
indicated a cased well to a depth of +218', with a 152' static ~ater
level. It appears that water enters at the 218' level. The well
produces a steady 4.5 GPM when drawn down to 218' The enclosed well
logs show that the neighboring wells draw from sand & gravel confined
aquifers at a depth of 162'-189' The local well logs have a similar
static water level and are overlain by clay and hardpan soil layers.
The surface topography is such that any seepage would be directed away
from the well loc~tion on m 10% slope to the south east.
The subsurface soil is a GM type with a perc. rating of
approximately 150. A water sample for coliform bacteria and nitrate
content was satisfactory. The well is located opposite of the house
from the septic leachfield and tank locations. The tank separation
distance requested should not endanger the aquifer, as the new tank
will be sealed on all connections and manholes.
Z¥~l. J.I I.~t'~i'X [~'I[1C]['""~.~Z~,4'~ ~' ~ P.( ...3X 1~650
, ANCHORAGE, A~SKA 9951~6650
O~ (907) 2~4111
A chorage
MA YOR
DEPARTMENT OF HEALTH & HUMAN SERVICES
June 10, 1987
Lou Butera, P.E.
Eagle River Engineering Services
P.O. Box 773294
Eagle River, Alaska 99577
subject: Lot 7 Lake Hill Acres Subdivision
Waiver Request WR87-034
Dear Mr. Butera:
Your request for a waiver of the 100 foot separation required
between the septic system and well on the subject property has
been granted. The required setback to the well has been waived
to 80 feet for the existing seepage pit and to 70 feet for a
replacement septic tank. These setback waivers are based on an
evaluation of hydrogeological conditions that indicate that
there is little potential for well contamination in this case.
These waivers are valid for the existing seepage pit only.
Should the exiSting pit require upgrade, applicable setback
requirements must be met. The new septic tank must be
installed with watertight couplings and manhole covers. This
waiver is valid for a two bedroom single family dwelling only.
Sincerely,
stephen S. Morris
Civil Engineer
On-site Services
cc Gus Andress, P.E.
Manager, On-site and Water Quality Programs
MUNICIPALITY OF ANCHORAGE
825 L. Street, Anchorcge, Alike 99501 264-4720
SmLS L~.- PERCOLATiON,TEST
14-
15-
16-
17-
18-
19-
20-
COMMENTS
PERFORMED BY:
SLOPE
SITE PLAN
WAS GROUND WATER ~ O S
ENCOUNTERED? L
E
IF yES, AT WHAT
· . ~EPTH?
Reading Date Gross Net
Time Time
,.. ~. o)~uo~.,,-- .~c~'~,
PERCOLATION RATE (minutes/inch)
BETWEEN FT AND '~" FT
TEST RUN Z~
Depth to Net
Water Drop
Performed For
GRE~'R ANCHORAGE AREA BOROUGtt
DEPAR'~ ~NT OF ENVtRONM~r~i,~L QUAL.?-
3500 TUDOR ROAD
ANCHORAGE, ALASKA- 99502' -' ·
Robert Bra~-elI
Legal Description: Lot23 Block ....... Subdivision
This Form Reports Soils--['6-g
CASE #____.__
Date' 'Performed 9/21/71
Tatro
Percolation Test
Depth
Feet
:/?: '. ~-2"
· .' L~.'t'¢ '
Soil Characteristics
Brown clavev silt (CL)
'Gray silty sand w/ fine gravel
(sM)
Gray sand (S?)
with silty sand seams and.containing
scattered'gravel
W~s Ground Water Encountered?_a~___-
If Yes, At What Depth?
1%
i
t
i
Reading Date Gross Time
Net Time
Depth to H20 Net Drop
t
Percolation Rate Minute
Proposed Installation: Seepage Pit x Drain Field
Depth Df Inlet Depth To Bottom Of Pit Or Trench .....
COMMENTS:
20~ square fee~ of drainage area is required per bedroom.
Test Performed By R. E. Carlisle Data Certified By ~ationai '£eat~ng ~ervices Inc.
, MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
· DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
f~,' ,4_
i. Oenerai Information Application Date { ..'::-?f
(a) Legal DescriptiQn (inclnd~ lot, block, subdivision, section, township, range)
Location (address or directions)
(b) Applicants Name~ ~ ,,~ le,t, iTelephohe - Home ,us,ness
Applicants Address._ ~',(~. ,, i..:~,~~'_J.,~ L~. i:..--
(c)Applicant is (check one) Lending Institution ~-~; Owner/builder ~--~;
Buyer ~'; Other ~ (explain);
(d) Lending Institution ~fl~!~ f~£~,l~,~ Telephone
(e) Real Estate Co. & Agent . /I.~-- [~ ~' ~
n:: /
(f) Mail the D to the following address:
2..Type of Residence
Single-Family ~ Multi-Family ~-~ Other (describe)
Number of Bedrooms __~5
3..W,ater Supply
Individual Well ~ Community ~-~ Public ~-~
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
4. Sewage Disposal
O~site ~ ~ublic ~--~ Comm=it.~ F~ Holding Tan~ ~:
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
[Page 1 of 2]
5. Engineering Firm Providin~ Inspections~ Tests~ File Search~ Data and Informatid~
As certified by my seal affixed hereto and as of the validation date shown below, I
verify that my investigation of this Health Authority Approval shows that the on-site
water supply and/or wastewater disposal system is safe, functional and adequate for
the number of bedrooms and type of structure indicated herein. I further verify that,
based on the information obtained from the Municipality of Anchorage files and from my
investigation and inspection, the on-site water supply and/or wastewater disposal
system is in compliance with all Municipal and State codes, ordinances, and regula-
tions in effect on the date of this inspection.
(ENGINEER SEAL)
Date
DHEP Approval
Approved for/~/ bedrooms
Approved ~ Disapproved__
Terms of Conditional Approval
CAUTION
THE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
(DHEP) ISSUES ~EALTH AUTHORITY APPROVAL CERTIFICATES BASED SOLELY UPON THE REPRESENT-
ATIONS GIVEN IN PARAGRAPH 5 ABOVE BY AN INDEPENDENT PROFESSIONAL ENGINEER REGISTERED
IN THE STATE OF ALASKA. THE DHEP DOES THIS AS A COURTESY TO PURCHASERS OF HOMES kND
THEIR LENDING INSTITUTIONS IN ORDER TO SATISFY CERTAIN FEDERAL AND STATE REQUIRE-
MENTS. EMPLOYEES OF DHEP DO NOT CONDUCT INSPECTIONS OR ANALYZE DATA BEFORE A
CERTIFICATE IS ISSUED. THE MUNICIPALITY OF ANCHORAGE IS NOT RESPONSIBLE FOR ERRORS
OR OMISSIONS IN THE PROFESSIONAL ENGINEER*S WORK.
(DHEP SEAL)
RR4/ej/D18
[Page 2 of 2]
7-19-84
MUNICIPALITY OF ANCHORAGE
DEPT. OF HEALTH &
ENVIRONMENTAL PROTECTION
WELL DATA
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
Legal Description:
Well Classification]. /~ ' c/~'~
Well Log P~esent((Y ~N) ~/
Total Depth / ~ ~3 Card to /?~
Static Water ~1 , J ~ ~ ~t At
Casing Height ~ve Ground ~ z
Electrical Wiring in ~nduit (Y~) /
Sep~ation Distance fr~ ~11:
To ~ptic/Holding TaDk on ~t /[3~.~ ~ ~
To ~arest Edge of ~sorption Field on ~t /~ ~
To Nearest Public ~%~r Line ~
OCT 1 19aa
Depth of Groutinq
Sanitary Sea]. on Casing
Depressicn Around Wellhead (Y/N)
; On Adjoining Lots O
; On Adjoining Lots
To Nearest Public Sewer
Cleanout/Manhole /~/~/~. To Wearest Sewer Service Line on Lot
Water Sample Collected'By fi',l,~/; ~'%~ ~ i.~A ; Date /~ /~ ~ /~ i¢
Water Sample Test Results ....... 7~l~/q '~ ~/~ ~ . ~ .
S~L::~'ZC/HOLD~G TANK
~te Install~.~ ? /~ % Size /3 /~'~ ~O. of C~sr~nts
Stan~i~s~) ~ / Ai~-tight Caps (Y~' / Foundation CleaQout (Y~)
~pression ~9e~ Ta~ (Y~) ~ Date Last P~d
P~ing~aintenan~ Con~act on File (Y~) ~; for
Holding Tapk High-Water Ala~ (Y~) ~/~ Te~rary Holding Tank Permit
Sep~ation Distan~s ~ ~ptic~{olding Tank:
To To o,, d tio. Z¢
TO ~o~rty Li~ ~ ~ To Dis~sal Field
To ~ter Main/Servi~ Li~ /O~ To S~e~, Pond, ~e, ~ Major ~aina~
Co.nents
Receipt= '~
Date Paid:
[Page i of 2] 2-15-84
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Square Feet of Absorption Area
DeDression over Field (Y/N)
Results of Last Adequacy Test
Type of System Design
Length of Field ~-~ /
Depth of Field 9 /
Gravel Bed Thickness ~ /
Standpipes Present (Y/N)
Date of Last Adequacy Test
Separation Distance from Absorption Field:
To Water-Supply Well /~)4; ! To Property Line / d
To Building Foundation *~' ! To Existing or Abandoned System cn
Lot A/~-- ; On Adjoining Lots ~ ~ 7~
To Water Main/Service Line /~; ~- To Cutbank(if present)
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area . ~.O f-
Con, rents
De
Date Installed'
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Electrical Codes (Y/N)
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test.
Meets MOA
Comments
Check Permitted Bedroom Rating Against HAA Request
I certify that I have checked, verified, or confor~d to all MOA HAA Guidelines in effect
on the date of this inspection.
Date
KB1/d5/s
[Page 2 of 2]
2-15-84
EXCAVATION
ROBERT A. SHAFER
WORK
August 30, 1983
CIVIL ENGINEER
694-2979
Carol Monroe
Dear Carol,
Reference: Lot 6; Lake Hill Acres Addition %1
A sewer system adequacy test was performed on the system located.on
the referenced property as you requested. The septic tank was
pumped and verified to have a capacity of 1000 gallons. The seepage
pit was tested by charging the system-Qith approximately 1700
gallons of water and after a period of 24 ho~rs approximately
532 gallons had percolated out of the crib.
It can be concluded from this test that the waste water disposal
~¥stem serving the two bedroom residence located on this property
· s currently functioning adequately. However, the system cannot
b~guarant~ed against subsequent failure.
At' the time the adequacy test was performed an inspection of the'
well was also made and found to be in accordance with current
codes. A water sample was also taken from the hose bib on the
side of the house and submitted to Chemical and Geological
Laboratories of Alaska. The results, the coliform bacteria
analysis indicated the water to be satisfactory.
· ~ ~ m~v ~ cf '~..-i~-.~
......... ~ -~ ~ serviCe, p~ease do not hesitate to contact
Sin(~ y,
/ ·
SS
cc: Municipality of Anchorage
D~partment of Health and Environmental Protection