HomeMy WebLinkAboutSCIMITAR #1 BLK 2 LT 11imitar Block Lot 11 #051 - 132-19 Municipality of Anchorage Development Services Department Building Safety Dh/sion On-Site Water and W~stewater program, 4700 S. Bragaw SL P.O. Box lg6tiS0 Anchorage, AK gg519-6650 v, vM.cLan~osage.a[us (907) 343-7S'04 Permit Number:. LEGAL DESCRIPTION ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELt. INSPECTION REPORT WastewaterSystem: ~i~New [] Upgrade Well: [] New [] Upgrade SEPARATION DISTANCES ABSORPTION FIELD TANK Septic n Holding ['1 S.T.E.P. r"'l Other. Septic Absoq3tion Lift Holding Put;tm/private I,~,~SKtur~ /.~ ~ Ta.k Field Station Tan~ I S~e (~ C~ ~ BENCH MARK Inspections performed ~,,.. 17034 E,¢e Ri,er Lo~p Road, !,~..204 ~Y' ~e RNer; Ala~k~ ~5~ Developmeht Se~ices Depa~ent Approval Reviewed snd epproved by:~ PERMIT NO. SW020222 PAGE 2 or Municil:7~li~c oF DEPARTMENT OF HE~,~_THANL) HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION · P.n. Box 196650 eAncho~ge, Al(lsk(l 99519-6650eTelephone~ 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 1 1, BLOCK 2, SCIMITAR #1 x' \ ,,' \ \ \ \ \ CO DBLI & NEW 1250 GALLON SEPTIC SPLITTER CO (;O1 P.I.D. NO. 051--152--19 ~IT2 LOT 12 PERmiT NO. SW020222 PAGE 3 o~ 3 Municip. oti-t oF An c h.o..r' p,, g.e, DEPARTMENT OF HEA~.TH AND HUH,AN SERVICES ENVIRONMENTAL SERVICES DIVISION .P.B. Box 196650 ~,,~Amcho,~o. ge, A_.t~.sko. 99519-6650 · Tet,e. phone: 343-4744 ON-SITE WASTEWATER DISPOSAL ~YSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 11, BLOCK 2, SCIMITAR #1 P.LD. NO. 051-132-19 ST1 FINAL GRADE/ S'[~,/- 98.7' GALLON SEPTIC TANK CO1 C-02-MT1._JCO1 -- 94.6' IC02 = 92.9' ~ /FINAL GRADE-N.. C03 ~ 92.7' s~CO1 = 88.9' C02 = 89.0' XX'-MT1 = 85.8' I ~C03 = 88.7' S> ] lC04 88.7' · ~ MT2 85.7' FCO ST1 ST2 DBL1 DBL2 CO1 C02 MT1 C03 C04 MT2 A 48.0' 50.0' 52.5' 55.0' 54.0' 55.0' 73.0' 34.5' 47.5' 80.0' 49.0' B 24.5' 36.0' 43.5' 45.5' 47.5' 92.0' 63.5' 87.5' 103.0' 80.0' 99.5' · ~o~7WATER FOUND 76.7' B.OJI. MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTE1NATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jul 11, 2002 Expiration Date: Jul 11, 2003 Permit Number: SW020222 Legal Description: SCIMITAR t/1 BLK 2 LT 11 Design Engineer: 0003 S & S Engineering Owner Name: Paul Bergeron Owner Address: PO Box 671347 Chugiak, AK 99567- Parcel ID: 051-132-19 Site Address: Lot Size: 56781 SQ. Fr. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All constr~ction must be in accordance with: 1, The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: '~~2 ~ Date: Issued By: ~'~~. ~ Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cl.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/~/ELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLI'NG Parcel I.D. O~l° I ,:~.~- / ~{ Permit Number SWO 20[[Z. Propertyowner(s) gO, H I B(~/"'geJeOrl Day phone Mailing address (1) ~ ~0~ ~1~ Mailing address (2) ~ ~;~, ~ Zip Code Legaldescription(Lot, Block&Sub'd.) R Legal description (Section, Township & Range) Lot Size ""~5 ~/"~<~::~c~ Acre~ THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub [] Swimming Pool [] Therapy Pool [] Number of Bedrooms Well Only [] Water Storage [] Jacuzzi [] Water Softening Unit [] I certify that the above information is correct. I fudher cedify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 17034 Eagle River I. eel~ Road No. 204 (Signature of property owner or authorized agent) Permit Fees: Date of Payment: 7/-'~/0 2.. Receipt Number: ~- ~.~ ~' (Rev. Waiver Fees: Date of Payment: Receipt Number: June 27, 2002 ROBERT C. COWAN. P.E. CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK 99519 REFERENCE: Lot 1 I, Block 2, Scimitar Subdivision It is requested that you issue a permit to install a sephc system to serve the proposed four bedroom dwelling on the referenced property. A test hole was excavated and a percolation test performed. The approximate location of the test hole is located on the attached site plan. At the time of excavation 5/28/02 water was found at 10 feet. After monitoring for seven days, water was found at 9 feet. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. If you require additional information, please contact us. Sincerely, RCC jj Enclosure 17034 NORTH EAGLE RNER LOOP · SUITE 204 · EAGLE R~/ER. ALASKA 99577 Z LOT 12 ~-,~ .~' ' '~ ~,. h BJJ/JHM I DESIGN CRITERIA: [ ~..:.L.//2~ ~,.,....~ 4 BDEM = 600 GPD SOILS = 0.45 GPD/SQ.FT. , ~ ~' i. ~ ~ a~T c cow~ /~ 600/0.45 = 1555 SQ.FT. REQ'D. = , X ~ ~/~ OBTAIN UTILITY LOCATES/ ~ PRIOR TO ANY EXCA~OH LOT 10 os~.l. SEPI'IC~ PROP ~J' qAREA 1250 GALLON DOUBLE SEPTIC TANK-- :~ DRAINFIELD CRIT 5.0' DEEP 4.0' EFFECTIVE 27' 5.0' W~DE ~ ALTER] CRIT~I SPLITTER~ 4.0' WIDE ~ 55' LON~' ~ ~ ~3' 2 ~ 69' E~/LONG = 171 ~ ~ /' AREA LOT 3 ALL PORTIONS OF SYSTEM WITtl LESS THAN 3.5' OF COVER REQUIRE INSULATION. LOT 4 THE E~:hNEER MAY VARY THE EXACT U£N$iONS AND DE:S~GN PARAMET[ c~ IN IHIE: FIELD, IF  ~'~ LOT 11, BLOCK 2, SCIMITAR S/D R,C.C. 7-10-02 DESIGN CRITERIA: erln{] 4 BORM = 600 GPD SOILS = 0.45 GPD/SQ.VT. 600/0.45 = 1333 SQ.FT. REQ'D. RF = 0.5 I ALL PORTIONS OF SY~ WITlt {~-SS THAN 3.5' OF COVER REQUIRE INSULATIOn. 6 10' UTILI:rY EASEMENT z Z LOT 5.0' DEE 4.0 5,er CONTRACTOR IS OBTAIN ANY EXCAVATION CRITERIA: EACH = 134' TOTAL Performed Fo~: Legal Desc~lplion: Municipality of Anchorage Development Se~lces Depadmenl Bund nD Safe~ OMs~ P.O. Box t966~ ~ge, ~ 99519-6650 ~.danch~a.e ak.us Soils Log - Percolation Test / SI~ Site P~n Oeplh (Feel) 3- 4- 7- 0.-,e.. 10- . ~o~... ~- 0).'.. ~2. ..- .~; '13- ~0 ~4~ t5- 16- 17- 18- ENCOUNTERED? ! s IF YES, AT WHAT DEPTH? 0 Deplh to Water After /~ / p Monitoring? :~ E Reading Date Gross Time Net Time Depth Io Water Net Drop 19- 20- COMMENTS 3o 70o PERCCA.ATIOH RATE _~{relnutesano~) ~ PERCtlOLEOIAMETER TEST RUN BET~NEEN FT AND FT PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE, DATE: Performed Fo~: Legal Description: Municipality of Anchorage DevelopmentSen/IcesDepartmenl ,~I-~[.-" ___ '~" eunding Sa[ely Division On-Site Water and Waslewater P[ogram P.O. Box 196650 Anchorage. AK 99519-6650 (907) 343.7904 Soils Log- Percolation Test / Slope -- Sile Plan Oeplh '~. 6-'¢/ 8- 10. ~'Ot 13- 14- 15- 16- 17- 18- 19- 20- WAS GROUND WATER ENCOUNTERED? IF YES. AT WIIAT DEPTH7 Depth Io Water Reading Date Gross Time Nel Time Depth to Water Net Drop o - U - ~<;,,.,. -o Il//v" .,1, 0 " " II '/~" bO I IQ '/~" 3/~, e ,t , ." '~ o 'L' II I 3...~ Il ~'1'" 3'/I" PERCOLATION RATE ~ ~ (minu~esancht PERC HOLE DIAMETER (7" 1EST RUN BETWEEN J~ FT AND ~' FT COMMENTS PERFORMEDSY: j~ I~t~-~ ~-~,1.,.,(,,,)' I ~'~t/w~2~ CERTIFYTtlATTHISTES~TW,~S PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 3'Lt.-31-2002 10:0,.~ S~,~S I~GI~,I~-RI~ 90"/ 694 1211 P.02 July 26. 2002 Reference: Lot l l; Block '2: Sc/mitar ~/I Subject: Owner llt~'.allation ofpri&'atc septic systcm 1'o V~'hom II l~,lay Concern: I am the owner Of the referenced lot and ~1 installing, the septic systcm on thc lot. ) am r~miliar and cxi'~:rienccd with the operation of thc required equlpmenL &s well as the in$:allation of thc septic I v, ill be installing the system in accordance with the design done by S &: ~ Engin,.~H.~;. and ,..,ill have S & ~ Engl.ccrlng do all the required inspect:ions snd documentation. Thank you. phone 317-6964