Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
T12N R3W SEC 33 LT 114 NE4 LESS E15'
TI 2N R3W ction 33 Lot 114 N #018-252-23 EXPIRED PERMIT Municipality of Anchorage Building SMcty Di~aslon P.O. Box 1~ * 4700 S. Bragaw Strect Anchorage, Alaska 99519-6050 · (907) 843-8301 h ttp://www.el.anehorage.ak.us October 8, 2001 Public Works Alvin & Dolores Wiita PO Box I 11762 Anchorage AK 99511 Subject: On-Site Water md/or Wastewater Penni[ Permit Number: SW00492 Legal Description: TI2N R3W Section 33 Lot 114 NE4 Less E 15' Dear Alvin & Dolores Wiita: An On-Site Water/Wastewater Permit, number SW00492, issued by this office for a single-family system, will expire on November 29, 2001. This permit was valid for 365 calendar days. If this was a well permit and the well has been drilled, a well log must be sent to this office for documentation of the installation and to close the permit. If this permit was for a wastewater disposal system, an original as-built inspection report must be sent to this office for review, approval and documentation. This as-built inspection report must be signed by the licensed Professional Engineer who inspected the installation ofthe system. As-built inspection reports are required to be submitted within 30 days of the completion of the system. If no system xvas installed under this permit, and you are still planning to install a well or xvastewater disposal system, a new permit must be obtained from this office. A new permit may be issued.pee of charge for a second year if the application for the renewal is received on or before the date of expiration of the original permit. When applying for a new permit, the fees are: $320.00 for a wastewater permit and $120.00 for a well permit. If you have any questions, please call this office at 343-7904. On-Site Water and Wastewater Program Enc: Copy ofpermit MUNICIPALITY OF ANCHORAGE Department of Health and Human Sen/ices On~S#e Services Program 825 L Street, Room 502 P.O. Box 196650. Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Nov 29, 2000 Expiration Date: Nov 29, 2001 Permit Number: SW000492 Legal Description: T12N R3W SEC 33 LT 114 NE4 LESS E15' Design Engineer. 0073 Haas & Associates Owner Name: Alvin & Dolores Wiita OwnerAddress: PO Box 111762 Anchorage. AK 99511- Parcel iD: 018-252-23 Site Address: Lot Size: 24750 SQ. FT. Total Bedrooms: 2 Permit Bedrooms: 3 This pen'nit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1, The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15. a subsurface soil absorption system under construction during freezing weather must be either. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. 5. The following special previsions. ENGINEER SHALL PERFORM ANOTHER SOILS TEST AT THE TIME OF CONSTRUCTION TO A MINIMUM DEPTH OF 15 FEET TO VERIFY THE ABSENCE OF BEDROCK Received By: Date: ,ssued, : cU. Date: q-O0 Rick Mystrom, Mayor Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 July 18, 1995 Alvin B & Delores M Wiita PO Box 111762 Anchorage, Alaska 99511 1762 Subject: T12N R3W Section 33 Lot 114 NE¼ Less E15' Permit #SW940244, PID #018-252-23 The subject permit, issued July 18, 1994 by this office for a single family well and/or on-site wastewater system, has expired as of July 18, 1995. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well log must be sent to this office for documentation of the installation and to close the permit. If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, _rely, J ds Cross, .E. P~ogram Manager On-site Services please call this office at 343-4744. eno: Copy of Permit cc: Haas and Associates PAGE 1 OF MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HUMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NLrMBER:SW940244 DESIGN ENGINEER:HAAS AND ASSOCIATES OWNER NAME:WIITAALVIN B & DELORES M OWNER ADDRESS:14400 SNOWSHOE LN ANCHORAGE, ALASKA 99516 DATE ISSUED: 7/18/94 EXPIRATION DATE: 7/18/95 PARCEL ID:01825223 LEGAL DESCRIPTION: T12N R3W SEC 33 LT 114 NE4 LES S E15' LOT SIZE: 24750 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTIONMUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASKA WASTEWATER DISPOSAL REGULATIONS (18AAC72) AND DRINKING WATER REGULATIONS (18AAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. 1 'CONSTRUCTION TO A MINIMUM DEPTH OF 15 FEET TOVERIFY.~H~. DATE: DATE: HAAS & ASSOCIATES, iNC. CIVIL ENGINEERING CONSULTANTS · MATERIALS TESTING · ENVIRONMENTAL SERVICES July 8, 1994 Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Attention: Dan Roth, P.E. Re: Lot 114 less east 15 feet, Section 33 TI2N R3W Dear Mr. Roth: The proposed septic system upgrade on the above-referenced lot will have little or no effect on the adjacent systems for tlie following reasons: 1. The neighboring systems are more than 75 feet away. 2. The area has large lots and granular soils that drain well. 3. All wells and surface water are over 100 feet from the proposed system. 4. Reserve space is adequate based on our test hole as well as previous test hole data. 5. The septic system will be mounded and seeded to provide drainage away from the system. 6. We are requesting that the depth to bedrock be verified during constmction. If you have any questions please call us at 344-4108 or fax us at 349-8791. Sincerely, Ilaas & Associates, Inc. Sandor Manyoky, P.E. Civil Engineer SM/slim 3900 E 112TH AVENUE · ANCHORAGE, ALASKA 99516 · TEL/FAX (907) 349-8791 HAAS & ASSOCIATES 3900 £. ZZ2th Ave. ANCHORAGE, AK 99~16 (907) ~9-8791 CHECKED BY DATE "X i" !'' ; ';: ......... HAAS & ASSOCIATES 3900 E. 112th Ave. ANCHORAGE, AX 99516 (907) 349.8791 DATE Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street. Anchorage, Alaska 99502-0650 SOILS LOG w PERCOLATION TEST PERFORMED FOR: 10- 13- 14- 15- 16- 17- Township, Range, Se'ction: '7"/~'~ t/~ .~ (A~ 5 3 Z SLOPE SITE PLAN ' 1/5' WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT O DEPTH? p E Gross Net Depth to Net Reading Date Time Time Water Drop g"~ I, I <; : t.o ~4 n i o ,. ,'... /. f 18- 19- 20- COMMENTS PERCOLATION RATE /' ~'" Im,nutesqnch) PERC HOLE DIAMETER TEST RUN BETWEEN "~ FT AND ~:~ FT ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DAT~ ~ --/ 72-008 (Rev. 4/85) HAAS ~ AS$OC/ATE$. ~NC. IClviL ENGINEERING CONSULTANTS · MATERIALS TESTING ' ENVIRONMENTAL SERVICES SYSTEM DESIGN GUIDELINES AND NARRATIVE EAST 12, LOT 114, TI2N, SEC33, R3W ON-SITE SEWER SYSTEM UPGRADE 1. This design is for a system upgrade from two-bedroom to three-bedroom single family residence with a 6.5 feet deep trench using gravity distribution. 2. Deep trench with 6.5 feet gravel, 13 SF absorption area per linear foot oftrench. 3. 3 bedrooms X 150 gpd/l.2 8pd/SF = 375 SF absorption area required, 375 SF/13 SF/LF = 28..9 feet, about 30 feet oftreneh required. 4. All materials, construction methods and required inspections to follow MOA rules and State ofAlaska D.E.C. regulations. The contractor is responsible for obtaining all required permits. The contractor is responsible for obtaining all required permits. The contractor is responsible for notifying the engineer and the MOA at least twenty-four hours in advance ofall inspections needed. 5. Contractor will insure no additions or cllanges have been made to the ~vell and septic systems on the adjacent lots prior to the time ofconstrucfion ofthis system. Ifany changes to those systems have occurred, the engineer should be immediately notified for review and possible changes as necessary. 6. The overburden will be removed to the underlying poorly graded sand (SP) material under any portion ofthe trench area. 7. The lot slopes down to tile south. The installation of the trench will have little or no effect on the surface drainage, ground water, or fl~e adjacent systems in the area. 8. The septic system should be properly maintained to include septic tank inspection and pumping on an annual basis. 9. The existing 1000 gallon septic tank is in good working order and will remain part of tile new system. 10. The existing crib will be abandoned. 3900 E 112TH AVENUE · ANCHORAGE, ALASKA 99516 · TEIJFAX (907) 349-8791 Rick Mystrom, Mayor MtmicipaB_ty of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 343-4744 July 18, 1995 Alvin B & Delores M Wiita PO Box 111762 Anchorage, Alaska 99511 1762 Subject: T12N R3W Section 33 Lot 114 NE¼ Less El5' Permit ~SW940244, PID ~018-252-23 The subject permit, issued July 18, 1994 by this office for single family well and/or on-site wastewater system, has expired as of July 18, 1995. A new permit must be obtained from this office for a well and/or on-site wastewater system NOT installed by the expiration date. If you have drilled the well, a well this office for documentation of the close the permit. log must be sent to installation and to If a licensed Professional Engineer has inspected the installation of the on-site wastewater system, the original as-built inspection report must be sent to this office for review, approval and documentation. All inspection reports must be submitted within 30 days of construction completion. When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit; $120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit. If you have any questions, please call this Sincerely, J~e's Cro s s ,%-/~. E'. P~ogram Manager On-site Services office at 343-4744. enc: Copy of Permit cc: Haas and Associates PAGE MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND HERMAN SERVICES P.O. BOX 196650, 825 "L" STREET, ROOM 502 ANCHORAGE, ALASKA 99519-6650 ON-SITE WASTEWATER DISPOSAL SYSTEM (UPGRADE) PERMIT PERMIT NUMBER:SW940244 DESIGN ENGINEER:HAAS AND ASSOCIATES OWNER NAME:WIITA ALVIN B & DELORES M OWNER ADDRESS:14400 SNOWSHOE LN ANCHORAGE, ALASKA 99516 DATE ISSUED: 7/18/94 EXPIRATION DATE: PARCEL ID:01825223 LEGAL DESCRIPTION: T12N R3W SEC 33 LT 114 NE4 LES S El5' LOT SIZE: 24750 (SQ. FT.) NUMBER OF BEDROOMS: 3 THIS PERMIT: 3 THIS PERMIT IS FOR THE CONTRUCTION OF: DISPOSAL FIELD SYSTEM ALL CONSTRUCTION MUST BE IN ACCORDANCE WITH: 1. THE ATTACHED APPROVED DESIGN. 2. ALL REQUIREMENTS SPECIFIED IN ANCHORAGE MUNICIPAL CODE CHAPTERS 15.55 AND 15.65 AND THE STATE OF ALASICA WASTEWATER DISPOSAL REGULATIONS (iSAAC72) AND DRINKING WATER REGULATIONS (iSAAC80). 3. THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY CALLING 343-4744 (24 HOURS) 4. FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING WEATHER MUST BE EITHER: A. OPENED AND CLOSED ON THE SAME DAY B. COVERED, SEALED AND HEATED TO PREVENT FREEZING 5. THE FOLLOWING SPECIAL PROVISIONS. 1 OF 7/18/95 SPECIAL PROVISIONS: ENGINEER SHALL PERFORM ANOTHER SOILS TEST AT THE TIME OF CONSTRUCTION TO A MINIMUM DEPTH OF 15 FEET TO VERIFY THE ABSENCE OF B_E~K. ISSUED BY: '~~ DATE: IIAAS & ASSOCIATES, INC. CIVIL ENGINEERING CONSULTANTS ,, MATERIALS TESTING · ENVIRONMENTAL SERVICES July 8, 1994 Mmficipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Atteution: Dan Roth, P.E. Re: Lot 114 less east 15 feet, Section 33 T12N I~.3W Deal' Mi'. Roth: The proposed septic syste~n upgrade on the above-refereoced lot will have little or no effect on tile adjacent systems for the following reasons: 1. The neighboring systems are more than 75 feet away. 2. Tile area has large lots and granular soils that drain well. 3. All wells and sm'fiqce water are over 100 feet fi'om the proposed system. 4. Reserve space is adequate based on our test bole as well as previous test hole data. 5. The septic system will be monnded and seeded to provide drainage away fi'om the system. 6. We are requesting that the depth to bedrock be verified during construction. If you have any questions please call us at 344-4108 or fax us at 349-8791. Sincerely, Haas & Associates, Inc. Civil Engineer SM/shin 3900 E 112TH AVENUE · ANCHORAGE, ALASKA 99516 * TEL/FAX (907) 349-8791 ,4/ HAAS & ASSOCIATES 3900 E, 112th Ave. ANCHORAGE, AK 99516 (907) 349.8791 SIIEET NO CALCULATED Dy CHECKED BY. ~o^~ =- ~OLo' / /5~, oP~ OF DATE 1519,0 ~ I~rI 15'' HAAS & ASSOCIATES 3900 E. 112th Ave. ANCHORAGE, AK 99516 (907) 349-8791 SHE~TNO OF CHECKED BY. DATE SCALE © Municipality of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Anchorage, Alaska 99502-0650 SOILS LOG -- PERCOLATION TEST CE ~467 3- 4 5 6 7 8 9 10 11 12 13 14 15 16- 17- 18- 19- 20- ,j //1'1¢ /(""~'~' DATE PERFORMED: Township, Range, Section: ~7-~/~,/~/' ~ SLOPE SITE PLAN WAS ~ROUND ~ATER ENCOUNTERED? Dale: Gross Net Depth to Net Reading Date Time : Time Water Drop /~ J~= (mlnutes/Jnch) PERC HOLE DIAMETER '~----FTAND ~' FT PERFORMED BY; ~1~'' ~"~ ' 4, , ~/F,.4,~¢~,&~ERTiFY T HAT THiS TEST WAS ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: 72-008 (Rev 4/85) PERCOLATION RATE __ TEST RUN BETWEEN PERFORMED IN ItAAS & ASSOCIATES, INC. CIVIL ENGINEERING CONSULTANTS · MATERIALS TESTING · ENVIRONMENTAL SERVICES SYSTEM DESIGN GUIDELINES AND NARRATIVE EAST 12, LOT 114, T12N, SEC 33, R3W ON-SITE SEWER SYSTEM UPGlLADE 1. This design is for a system upgrade from two-bedroom to t!n'ee-bedroom single family residence with a 6.5 feet deep trench using gravity distribution. 2. Deep trench wltb 6.5 feet gravel, 13 SF absoqttion area per linear foot of trench. 3. 3 bedrooms X 150 gpd/l.2 gpd/SF = 375 SF absorption area required, 375 SF/13 SF/LF - 28..9 feet, about 30 feet of trench required. 4. All materials, construction methods and required inspections to follow MOA rules and State of Alaska D.E.C. regulations. The contractor is responsible for obtaining all required permits. The contractor is responsible for obtaining all required permits. The contractor is responsible for notifying the engineer and the MOA at least twenty-four honrs in advance of all inspections needed. 5. Contractor will insure no additions or changes have been made to the well and septic systems on the adjacent lots prior to the time of construction of thls system. Ifany changes to those systems have occurred, the engineer should be hnmediately ootified for review and possible changes as necessary. 6. The overburden will be removed to the under134og poorly graded sand (SP) material m~der any po~.ion of the trench area. 7. The lot slopes domt to the south. The installation of the trench will have little or no effect on the surface drainage, grouod water, or the adjacent systems in the area. 8. The septic system should be l)roperly maintained to include septic tank inspection and lmmping on an annual basis. 9. The existiog 1000 gallon septic tank is in good working order and will remain part of the new system. 10. The existing crib will be abandoned. 3900 E 112TH AVENUE · ANCHORAGE, ALASKA 99516 · TEL/FAX (907) 349-8791