Municipality of Anchorage Page 1 of 3
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us (907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW020062 PID Number: 051-793-36
Name:
MM&M Contracting
Wastewater System: New
Address:
P.O. Box 670495 Chu iak AK 99567
ABSORPTION FIELD
Phone: Number of Bedrooms:
688-1236 Four 4
5' Wide Shallow Trench
LEGAL DESCRIPTION
Soil Rating:
Total Depth from original grade:
.8 GPD/F1'
9 Ft.
Block: Lot: Subdivision:
Depth to pipe bottom from original grade:
Gravel depth beneath pipe:
2 19 Glenn View Est. West Phase II
3
6
Ft.
Ft.
Township: Range: Section:
Fill added above original grade:
Gravel Length:
1 Ft.
64 Ft.
Well: AWWU Water System
Gravel width:
3
Number of lines:
1
Distance between lines:
N/A
Ft.
Ft.
Classification (Private, A, B. C):
Total Depth:
Cased to:
Total absorption area:
Pipe Material:
Ft.
Ft.
768 Fc
ASTM D3034 PVC
Driller.
Date Drilled:
Static Water Level:
Installer:
Date Installed:
Ft.
MM&M Contracting
6/7-11/02
Yield:
Pump Set at:
Casing eight Above Ground:
TANK
GPM
Ft.
Ft.
SEPARATION DISTANCES
® Septic ❑ Holding ❑ S.T.E.P. ❑ Other:
To
Septic
Absorption
Lift
Holding
ublic/Private
Manufacturer:
Capacity in Gallons:
From
Tank
Field
Station
Tank
Sewer Line
Anchorage Tank
1,250
Well
>200'
>200'
N/A
N/A
>25'
Material:
Steel
Number of Compartments:
Two (2)
Sudace Water
>100'
>100'
N/A
N/A
LIFT STATION — NONE ON LOT
Lot Line
>5'
>10'
N/A
N/A
ize:
anu ac urer:
Gal.
Foundation
>5'
>10'
N/A
N/A
Pump on' level at:
in.
'Pump o level at:
in.
High water alarm at:
in.
Curtain
None
Noted
Pump Make & Model
Electrical Inspections performed by.
Drain
Remarks:
2" Insulation Atop Septic Tank.
BENCH MARK
Location and Description:
Finished Floor.
Assumed Elevation:
100.0 Ft.
Engineer's Stamp
OF 1
AV �i
�,
Inspections performed by: Mike AndersonDates: 15t 6/7/02
;'' 49Th 4
nd
2 6/7/02
% �..... ..
00 •MICHAEL•E„ANDERSON
Department of Health d Human Services approval�%;
�
No.
Reviewed �� %
' 3 Z
CE-4381 :##_Q_' AV
:
and approved by: �' ' Date:
%0FESSO�'
cRev. 10/99)♦��
Municipality of Anchorage
DEVELOPMENT SERVICES DEPARTMENT
• 4700 South Bragaw Street Anchorage, AK 99519.6650 - 343.7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number SW020062
POLLY
CIRCLE
Page 2 of 3
PID No. 051-793-36
C4
Alternate
Site
A B
S1 12.8 44.9
S2 19.3 46.7
M1 48.8 28.1
C4 35.6 80.9
C5 48.5 29.3
PLAN AS -BUILT
SCALE 1" = 40'
t'1
q t
49th
•
, MICHAEL E. ANDCRSON TEE
i
•�C�Jjt No. C[-4381 .474:
94.
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On -Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW020062
FF=1
PID No. 051-793-36
ru
c S �
U t- U
��
.
PROFILE AS -BUILT A91th
Scale: 1" = 10'
7
UiCHAEL E. ANDERSON � p
i
1,10. CE -4381 : a \�
� F rAr
1
2
3
4
5
6
7
8
9
14
15
16
17
<
4 a'
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT/ON-SITE WATER AND WASTEWATER.(3 GRQM,,
4700 SOUTH BRAGAW STREET, ANCHORAGE, AK 99502-0605 ' CE w.
SOILS LOG — PERCOLATION TEST �F°Qa e
PROJECT #: M0229a�°pSS��'�
MM&M CONSTRUCTION / PAUL MYERS `' 4�:' 11202
PERFORMED FOR: DATE PERFORM'�D
LEGAL DESCRIPTION: LOT 19, BLOCK 2. GLENN VIEW WEST SUED.
�%%� TEST HOLE # 2 SLOPE SITE PLAN
F/ /' / I 0G/0B
DENSE SILTY -SANDY -GRAVELS SM -GM
WAS GROUNDWATER
ENCOUNTERED?
IF YES, WHAT DEPTH?
DEPTH OF WATER
AFTER MONITORING:
DATE:
I
<5/1
S
L
0
P
E
N
TH1 TH2
O O
NO SCALE
< 5%
READING DATE
GROSS
TIME
NET
TIME
DEPTH OF
WATER
NET
DROP
Start 6/11/02
15:30
12"
1
16:00
30
8.125"
3.875"
Recharge
16:00
12"
2
16:30
30
8.125"
3.875"
Recharge
16:30
12"
3
17:00
30
8.125"
3.875"
PERC RATE: 7-7 MIN./INCH PERC. HOLE DIAMETER: 6
TEST RUN BETWEEN 5.5 FT. AND 6.5 FT.
COMMENTS: NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST
TEST PERFORMED BY: T.L. KIMBROUGH I, MICHAEL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE
WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 9/27/2002
FROM : COUtfTR' REALTY
S: •
PHONE NO. : 9376881238
Sep. 16 2002 09:15AM P2
Y•
o '.
•
•
•
•
., .t of A0000C��A
at*r a_
•
r"
•
•
•
AS -BUILT .
•
•
I hereby certify that I have surveyed the fofowing desci;led
p;;peztr: L o r -I 4. 8 to 2,
5L•,.t t/t :... er arm: Via.syJ nm-+-• tire. Z. . •
5u:c i � `T -t rill ��') • ••
&ieho?ase Reowding. predict;. Alaska, and that ther'ietprove-'.
menta situated thereon are wjthin the Property lines and do not :
iiveriap or er'xrbich'bn et! property Iymg adjacent thereto, that.'- '
haitnproventeries.on propertytymga adaacrat thereto 'encroach
cultic minis' es n.quesoon and that..diere ere no ioadways..
transmission fates or. other warble easements on said prbperty '
.except as indica ed hereon: ' • • •
Dated a E Rivet Alaska . ..
this. Si .._, ,sc f'_• -.floz.
ROBERT C. JOHNSON 'ACT-
SCALE:
C "SCALE: •:;:. Registered [arid Surveyor No:BBO-LS'•'
'Boa 77-0456, Eagle River. Alaska 99577 Z.
.
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
% 4' 2=f tb/oz e Aro
Z=°r
Date Issued: Apr 12, 2002
Expiration Date: Apr 12, 2003
Permit Number: SW020062 Parcel ID: 051-793-36
Legal Description: GLENN VIEW ESTATES WEST PH 2 BLK 2 LT 19
Design Engineer: 0014 Anderson Engineering
Owner Name: MM&M Contracting
Owner Address: PO Box 670495
Chugiak . AK 99567 -
Site Address:
Lot Size: 40489 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
E Disposal Field U✓ Septic Tank 0 Holding Tank ❑ Privy [j Private Well 0 Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
PERMIT CONTINGENT ON ADDITIONAL TEST HOLE LOGS AND PERCOLATION TESTS BE SUBITTED PRIOR
TO THE CONSTRUCTION OF THE SYSTEM FOR OUR REVIEW WHICH VERIFY THE SOIL CONDITIONS.
PERCOLATION TESTS TO BE RUN AT 6 FEET DEEP
Received By:
Issued By:
Date: (HZ-02—
Date:
HZ-02 -
Date: y/iZ/oz—
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
0
Parcel I.D. OLS -/-773 -310 Permit Number SW
Property owner(s) MM&M Contracting, Inc. Day phone 688-1236
Mailing address (1) P.O. Box 670495 Chuglak, AK 99567
Mailing address (2) Zip Code
Legal description (Lot, Block & Sub'd.) Lot 19, Block 2, Glenn Vlew Estates West Subdivision Phase II
Legal description (Section, Township & Range)
Lot Size LSO 4/$ 9 Acres/Sq.Ft. Number of Bedrooms Four (4)
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
® Well Only
O Water Storage
0
0
0
❑ Jacuzzi 0
❑ Water Softening Unit 0
0
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:as
�n. Waiver Fees:
Date of Payment: .7$8 y/$/d a Date of Payment:
Receipt Number: / $O ''3 Receipt Number:
(Rev. 12/00)
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 5224779 (FAX)
April 7, 2002
Municipality of Anchorage
Development Services Department
On -Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 19, Block 2, Glennview Estates West Subdivision Phase II
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer.
The owner of Lot 19, Block 2, Glennview Estates West Subdivision Phase II intends to
construct a new four-bedroom home on the lot. We are therefore requesting a permit
be issued for the construction of a new septic system to serve the proposed home. The
attached Site Pian and backup documentation identify the location and configuration of
the new septic system and the parameters used In the design. Also identified on the
plans are the location of the water service line on the lot and the test hole location along
with the septic systems located on nearby lots. Existing drainage patterns are shown
and will not be altered by the development of the lot.
We recognize the soils information submitted with this permit application for this system
is Tess than satisfactory. We are requesting, however, that the permit be issued based
on this information as the subdivision has been proven in the past to have suitable soil
conditions for the construction of on-site system. Weather conditions at this time make it
difficult to complete additional test holes without increased costs. Additional test hole
logs and percolation tests will be submitted prior to the construction of the system for
your review which verify the soil conditions.
The test hole placed near the location of the proposed absorption trench indicates clean
gravel and sand with varying amounts of silt. The percolation test completed in the
material resulted in a rate of slightly more than 7 minutes per Inch. No groundwater
was found during the placement of the test hole and none was noted during the
monitoring period. We are therefore proposing to place a 3' wide deep absorption
trench system with 6' of gravel beneath the distribution pipe. The total depth of the
trench will be 9'. The distribution pipe will be placed at 3' below the ground surface to
provide sufficient drop from the septic tank to the absorption trench. The total length of
the new absorption trench will be 63'.
The ground surface on the lot slopes as shown on the attached Site Plan with very little
to no slope near the proposed septic system site. The new absorption trench will be
constructed on a fairly flat surface in conformance with Municipal requirements and
parallel to ground contours where possible. All components of the new septic system
• Lot 19, Block 2, Glennview Est. West, Phase II
April 7, 2002
Page Two
will be constructed a minimum of 10' from the water service on the lot.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse Impact on the wells
in the area or those to be constructed in the future. The subdivision is currently
served by a community water system.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, If constructed as designed, will have no adverse impact on drainage
pattems in the area. The current drainage pattem will be maintained.
Sincerely,
t,G
Michael E. Anderson, P.E.
Attachments
ttttttt
t"P „ .» � •••
To1 MICHAEL E. ANDERSON W a
%?;1/41. No. cE-4381 -�:
f 0.
Kat 3-CS.00.0cis
i'- —3 e r++al.t .Q
grit!
s .s..-.ee "14i
..'- �,.}.R.-.te r ...q
y. :,rw.rrKp 145.70.00$
< �apn3 .JAl
4'
7c•-•`• \
Is
1
IPS
a.
rto
w
inn
C L •
-
00'91.
w 10 Ott SZS.W.tnn
s
0
r..
a -
M
cc:
381•28111-C 27910
Ur ac xsw.Wa
O
n
'0t'
22
VACANT
o0'9n
.3
tt n:
s .-fa
'h t tir
g :t17
n
•
IY.
•
'ot,` sa
r. v _
i1 `t
44
:I7 N0 _5
•
1 1 oa,r
oF
ginn''. 4444
�p
41'3's4 - 0Q:OO$$ i -♦ '�-1K'
tiLAE
THIS PROJECT
h
a°
e1.,
rav
°ter
a
e•
N C
Art
V(' \\\qo.,) /
\+. /.
\
`Y1. \ / ... C, eb
o 'z i�T.':'tni 4'- .. . - q� . A.
5'raOt
3.
'14! 49th
•
•
•
SCALE 1" = 100'
WCNACL E. ANDERSON
♦ N0. a-1361
4 PRor (SO- 404P
4444444444444444444
AREA SYSTEM PLANCLe
a
A
O!
0
O!
F
0
$4 144
TH
aan
SepticGTanx
LOT 19, BLOCK 2
GLENNVIEW ESTATES WEST
PHASE 2
X
EffectiveXDepthiAL. T -nch
Alternate Site
SITE PLAN.
SCALE 1" = 40'
LC/Mk
/
l 49th
r`t WCHACL E. ANDERSON
I1 JA No. CC -438140.
... PALFESSt 1:*
I it at
LOT 19, BLOCK 2, GLENNVIEW ESTATES WEST
SUBDIVISION, PHASE II
DESIGN FACTORS:
Four Bedroom Home
Pere. Rate: 7.3 Min./Inch
Avg. Application Rate: .8 GPDISF
SYSTEM REQUIREMENTS:
Deep Trench System
1,250 Gallon Septic Tank
6' Drain Field Rock
4 Bedrooms X 150 GPD /.8 GPDISF = 750 SF of Absorption Area
750SF/12 SF/LF = 62.5 LF Trench Length
Therefore: Construct An Absorption Trench 63' In Length by 3' Wide With 6' of Drainfield
Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing
Ground. Total Depth of Trench to Be 9' from Existing Surface. Mound Over Trench or
Provide 2" of Insulation to Provide Frost Penetration Protection.
NOTE:
2.6"
6'0"
G
i
6"
Natural
:Backfill
Ceotextile
Fabric
it
• S"• Perforated
PVC (Slots Down)
• }
r.
aiiia\i' e••hryi ic5w
• .
)
Drainfield
Rock
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 25' From Water Service Line.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Wells in the Area.
Municipality of Anchorage
Development Services Department/Building Safety Division
Onsite Water and Wastewater Program
4700 South Bragaw Street Anch., AK 99519
SOILS LOG - PERCOLATION TEST
Performed For: Arctic Devco/Tumer Construction Date Performed:
Legal Description: Lot 19. Block 2 Glenn View West Estates Phase 11
SLOPE
North
1 _ OG/OL
Loose & Soft
2 Thin Layers
GP/SP
3
SITE PLAN
:2/ 1-•
ry�
.•4
i
i_.... -
�� M2RACL E. ANDERSON Ey
No. CC -•3H' !
4/20/99
TESTHOLE NO. 1
4 See Site Plan
5
6 SM/GM
Med. Dense
7 Fine Sand
w/Gravel
8 Cobbles to 6"
9
10
11 Silt Increasing
w/Density
12
13
14
15
16
17
18
Bottom of
Test Hote
South
Was Groundwater
Encountered? No
If Yes. What Depth?
Depth to Water
After Monitoring
Date:
5/15/99
None
S
L
0
P
E
Reading Date Gross Net Depth To
Time Time Water
1 21 -Apr 2:35 7"
2 3:05 30 2-13/16"
3 3:06 7"
4 3:36 30 2-14/16"
5 3:37 7"
6 4:07 30 2-14/16"
Net
Drop
Perc. Rate: 7.3 Min./Inch Perc. Hote Diameter: 6"
21 Test Run Between 3 Ft. and 4 Ft.
Comments: Perc. Cavity Presoaked Prior to Test. Test Hole Placed During Construction
Performed By: KND. I. Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 414/02
4-3/16"
4-2/16"
4-2/16"
ONSITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 19, BLOCK 2, GLENNVIEW EST. WEST SUB., PHASE II
GENERAL:
1. The scope of this project includes the procurement and placement of a
new 1,250 gallon septic tank at the location shown on the Site Plan.
Work also includes the construction of a new 63' long X 3' wide X 6'
effective depth absorption trench at the location also shown on the
Site Plan and at the configuration shown. The distribution line in the
trench will be placed at 3' below the existing ground surface. Total
depth of the trench will be 9' below the existing ground surface. The
new absorption trench must be placed a minimum of 10' from the
water service line on the property.
2. Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
4. Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250 -gallon septic tank must be procured from an approved
source and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
Lot 19, Block 2, Glennview Est. West
April 7, 2002
Page 2 of 3
6. A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
Lot 19, Block 2, Glennview Est. West
April 7, 2002'
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with Tess than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as -built of the completed system.
MUNICIPALITY OF AmCHORAGE
o .,.-
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval
Parcel I.D. 051-793-36-000
Expiration Date: 9/11/2024
Leqal description GLENN VIEW ESTATES WEST PH 2 BLK 2 LT 19
Site address 21242 POLLY CIR Chugiak AK 99567
Current property owner(s) LANGLEY SCOTT C &ANTHONY ROSADO
X The On-site system(s) is/are approved for 4 bedrooms
Conditional approval for
Comments or advisories:
a
bedrooms, with the following stipulations:
Original Certificate Date: 2/28/2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory X Arsenic Advisory
Other
COSA Approval—June 2022
Development Services Department Phone: 907-343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Certificate of On -Site Systems Approval Application
1. GENERAL INFORMATION
Parcel I.D. 051-793-36
Complete legal description GLENN VIEW ESTATES WEST PHASE 2; BLOCK 2, LOT 19
Location (site address) 21242 POLLY CIRCLE, CHUGIAK, AK 99567
Current property owner(s) SCOTT LANGLEY Day phone 907-315-1296
2. ON-SITE SYSTEMS SIZED FOR 4 BEDROOMS
3. TYPE OF WATER SUPPLY: ❑ Private Well ❑ Private Well serving 2 dwelling units
❑ Private Well serving 3+ dwelling units 0 Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: ❑® Private Septic ❑ Private Septic serving 2 dwelling units
❑ Holding Tank ❑ Community Septic or Public Sewer
5. SEPTIC TANK: ❑■ Steel ❑ Plastic ❑ Concrete ❑ Fiberglass
Age 22 - See advisory if steel older than 20 years
6. ABSORPTION FIELD: ❑ AWWTS ❑ Bed FE -1 Deep Trench ❑ Wide Trench ❑ Seepage Pit
Waiver request for:
Expedited review requested: ❑
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On-site staff
to verify the accuracy of the information provided.
COSA Fee $ L] Waiver Fee $
Date of Payment Z / 2 i'/ -z' -Z 7 Date of Payment
COSA # 0 S C 2 `� 1 0 Ll 7 Waiver #
COSA Appliwfion_June 2022
CASA Checklist
Legal Description: GLENN VIEW ESTATES WEST PHASE 2; BLOCK 2, LOT 19 Parcel ID: 051-793-36
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system 1
X-MCELL DATA
❑ Well log i
Date drilled
PUBLIC WATER
Onsite (or attached) Well production at time of
Cased to ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground)
Date of flow test for CO
ft
Static water at beginning of test ft.
B. TANK DATA
Measured operating fluid level in septic tank 5
Date of pumping 9/11/2023
❑ Required maintenance completed, if AWWTS
Comments:
D. ABSORPTION FIELD DATA
Which system tested (date installed) 6/7/2002
WE ALL standpipes present per record drawing
Total measured depth from grade 10.2 ft (max)
Measured depth to pipe invert from grade 3.6 ft (min)
❑ N/A — pressurized field.
❑ Per record drawings, field is insulated.
❑ Monitor tubes go to bottom of effective.
If not, state depth into effective 5.75
❑ Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced _gallons date
Any rejuvenation treatment (past 12 months) N/A
If yes, enter date
Water storage tan me gallons
Well di ' ed for coliform test? El Yes ® No
Coliform bacteria is Negative
rate mg/L ❑ Nitrate less than MRL (ND)
Arsenic ug/L ❑ Arsenic less than MRL (ND)
Collected by _
Date
IFT STATION
❑ Requir intenance comp)
Age of lift station ars
Lift station m al
Adequacy test date 2/20/2024
Results ❑■ Pass
Fluid depth prior to test 40.25 in
Water added 691 gal
New fluid depth 54 in
Elapsed time 195 min
Final fluid depth 50.5 in
Absorption rate 600+ gpd
FIELD STATUS — POST RECOVERY
Effective depth (per record drawings) 72 in
Effective depth used *53.5 in
Effective depth remaining *18.5 in
Comments/Deficiencies: *MEASUREMENTS CALCULATED BASED UPON ELEVATIONS TAKEN DURING TEST.
COSA Checklist June 2022
E. SEPARATION DISTANCES
fftra.eyivate Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Li on Lot > 100' Community Sewer Manhole/ ut > 100'
Yes if No ft ❑ Yes if No
Neighboring Tank > 100' ❑ Yes i ft P ' ewer/Septic Line > 25' ❑ Yes if No
Absorption Field on Lot > 100' 0 Yes if No Tank > 100' ❑ Yes if No
Neighboring Absorption Field Animal Contain 0' ❑Yes if No
❑ Yes if No ft
Manure/Animal Excreta Storage >
Co Sewer Main > 75' ❑ Yes if No ft ❑ Yes i
0 N/A — Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10' ❑ Yes if No *5+ ft Surface Water > 100' M Yes if No
Tank to Property Line > 5'
0 Yes
if No ft
Field to Property Line > 10'
Q Yes
if No ft
Water Main > 10'
Yes
if No ft
Water Service Line > 10'
Q Yes
if No ft
Wells on Adjacent Lots:
Private Wells > 100' Yes if No _
Community Wells > 200' 5� Yes if No _
If tank or field is under driveway comment below
F. ENGINEER'S COMMENTS
*MET SEPARATION DISTANCE AT TIME OF INSTALL. TANK IS UNDER DECK (<30")
ft
ft
ft
ft
ft
m
ft
ft
ft
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On -Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm Gamess Engineering Group, LTD. (GEG) Phone
Engineer's Printed Name Jeffrey A. Garness Date _
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system in
accordance with the guidelines and regulations established by the Municipality of Anchorage and industry
practices. The reported results describe the condition of the system/s on the date/s of the evaluation.
Separation distances were measured to readily identifiable features. Hidden defects or encroachments may
exist that were not identified during the evaluation. The operational life of all wells and septic systems depend
upon a variety of variables, including (but not limited to) soil conditions, groundwater levels (that may fluctuate
during the year), quality of construction (materials and workmanship), and the water usage of the family utilizing
the system/s. These conditions can vary, and are outside the control of GEG. Satisfactory test results do not
guarantee future performance of the system/s; therefore, GEG makes no warranty (express or implied) regardinj
the future performance of the well or septic system. GEG makes no representation whether an alternative well
or septic system can be installed on the property in the event either of the current systems fail to perform
adequately in the future. The content of this report is for the sole benefit of the person/party that retained GEG
to perform the evaluation. Reliance upon the information provided in this report by any other person or party
(including subsequent property purchasers) is not authorized, nor will it confer any legal right whatsoever.
COSA Checklist June 2022 #AEccesa
907-337-6179
OF..! U°a4
f��ej Gornes .•�
P o
M0NMPAUTV OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
On -Site Water and Wastewater Section
www.muni.org/onsite
Septic Tank Advisory
Certificate of On -Site Systems Approval # OSC241044
Subdivision: Glenn View Estates West Phase 2 Block:2, Lot: 19
907-343-7904
Fax: 343-7997
The septic tank for this property is 22 years old. The average life of an asphalt
coated steel septic tank is 20 years. Typical replacement costs are $10,000 or more,
not including engineering, surveying or MOA permitting fees.
This advisory must be attached to all copies of the subject Certificate of On -Site
Systems Approval.
This is an example of what the metal of a 30 year old steel tank MAY look like.
00
CD
z
Aa_ae'we' orl '0
Radius= 50.001
Length= 33,50,
Detta= 38'23'18'
Cord= 32,88,
Cord Hearing= N15'541141W
S 86"4235' E
r— — I �
Drjveit�Y
"4m L J
12' Wlde
po,,4ed
Gray of See
see
-P DETAIL
LOT 19 Group of
'P k/ P
LEGEND
(S) Septic Vent Pipe
Chain Link Fence
Wood Fence
aq.9,
DETAIL
(Not To Scate)
1 24.7
23.3'
16.5' I
61 1 1 2es,
Deck 2 -Story
Frame
to, 4..s,\.,. House
6' 36,
,4.5' .,
1315,
34'
14'
30,
POLLY
CIRCLE
TeL & Etec
Easenent
I hereby certify that I have surveyed the fol.loAring described
Lot 19. Block 2, Glenn View iew Estates West Phase 2, Flat
No 2000-80, Anchorage Recording District, and that no encroachments
P
xi t except as indicated hereon. This As -built will only show the
exist P
Qh No. 10303
Nz%
easements that appear on the recorded subdivision plat No. 2000-89,
...
Anchorage Recording District; under no circumstances should this data
.... ........
hereon be used for the construction or establishing of boundary or fenci.. lines.
Glenn View Estates West Ph 2
ASBUILT SURVEY
APB Land Surveying
o 2.5 so
6 .,
Lot 19 Block 2
Ch I S
Cordie David i eryi S
East Prince of Peace Drive
SCALE 114 FM12204
Depicted on: Plat No. 2000-89
P. O. Box 671733
Eagle River, Alaska 99577
Anchorage Recording District
Chuglack, Alaska 99567
Surveyed: February 3, 2015
GRID: NW1459
0P_WWD.MC
CHECKM.
(907) 227-1361
Parcel I.D. 051-793-36
Municipality of Anchorage
On -Site Water and Wastewater Program
(907) 343-7904
Certificate of On -Site Systems Approval
Expiration Date:
1. GENERAL INFORMATION:
Complete legal description GLENN VIEW ESTATES WEST PHASE 2; BLOCK 2, LOT 19
Location (site address) 21242 POLLY CIRCLE CHUGIAK AK 99567
Current Property owner(s) AL ADAIR Day phone 841-0630
Mailing address 21242 POLLY CIRCLE CHUGIAK AK 99567
Real Estate Agent GORDON SLOAN Day phone 244-3381
2. TYPE OF DWELLING:
N Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
❑
Individual
Individual Water Storage
❑
Holding Tank
❑
Community Class Well
❑
Community
❑
Public Water System
©
Public Sewer
❑
WaiverNariance request for: uistan
Received by: Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ $550
Date of Payment 3 10 a ��
Receipt Number 0751/76
COSA # OSC211100
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
J
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm: Garness Engineering GrouR. Ltd (GEG) Phone: 907-337-6179
Address: 3701 East Tudor Road Suite 101- Anchorage Alaska 99507
Engineer's Printed Name: Jeffrey A. Garness Date:
In conducting this evaluation, GEG provided an engineering evaluation of the well and/or septic system
in accordance with the guidelines and regulations established by the Municipality of Anchorage and
industry practices. The reported results describe the condition of the system/s on the dale/s of the
evaluation. Separation distances were measured to readily identifiable features. Hidden defects or
encroachments may exist that were not identified during the evaluation. The operational life of all wells
and septic systems depend upon a variety of variables, including but not limited to, soil conditions,
groundwater levels (that may fluctuate during the year), quality of construction (materials and
workmanship), and the water usage of the family utilizing the system/s. These conditions can vary, and
are outside the control of GEG. Satisfactory test results do not guarantee future performance of the
system/s; therefore, GEG makes no warranty (express or implied) regarding the future performance of
the well or septic system. GEG makes no representation whether an alternative well or septic system
can be installed on the property in the event either of the current systems fail to perform adequately in
the future. The content of this report is for the sole benefit of the person/party that retained GEG to
perform the evaluation. Reliance upon the information provided in this report by any other person or
party (including subsequent property purchasers) is not authorized, nor will it confer any legal right
whatsoever.
6. DSD SIGNATURE
System #1 Approved for _�_ bedrooms
System #2 Approved for
Disapproved
Conditional approval for
bedrooms
bedrooms, with the foll
r--,) lZ �� ►" �� v
Q. CE -795-7. `
0; a.,Si�nU`
#AECC884
G\Q��\iY OF,�����!
i^
J�
�g ON-SITE
O
WATER AND
tRtiK443-p —
nrATER
z
PROGRAM
`01
Jy))))1) M I'.
Original Certificate Date:
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist_ Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet -1 0.10-112 doc
Legal Description: GLENN VIEW ESTATES WEST PHASE 2; BLOCK 2, LOT 19 Parcel ID: 051-793-36
If more than 1 septic system on lot: COSA Checklist # 1 of 1 Structure served by this system 1
ELL DATA PUBLIC WATER
❑ Well log ed with Onsite (or attached)
Date drilled
Total depth ft
Cased to ft
❑ Sanitary seal is functioning correctly
❑ Wires are properly protected
Casing height (above ground)
Date of flow test for COSA/
Static water lev eginning of test
Co ft.
B. TANK DATA
Age of tank(s) <19 years
Tank type/material STEEL
Measured operating fluid level in septic tank *50"
❑ Standpipes/foundation/ cleanout per record drawing
Date of pumping 10
D. ABSORPTION FIELD DATA DEEP TRENCH
Which system tested (date installed) 6/7/02
❑ ALL standpipes present per record drawing
Total measured depth from grade 10.1 ft (max)
Measured depth to pipe invert from grade 3.6 ft (min)
❑ N/A — pressurized field
❑ Monitor tubes go to bottom of effective. If not, state
depth into effective
Well production at time of test m
Water storage tank volum gallons
Well disinfecte coliform test? ❑ Yes ❑ No
❑ C m bacteria is Negative
Nitrate mg/L ❑ Nitrate less than MRL (ND)
isug/L [:JArsenic less than MRL (ND)
Collected
Date of Sample
STATION
❑ Requir aintenance com
Age of lift station ye
Lift station material
Adequacy test date 2126/21
Results ❑✓ Pass For 4 bedrooms
Fluid depth prior to test 32.75 in
Water added *788 gal
New depth 51 in
Elapsed time 246 min
❑ Code -required soil cover over field Final fluid depth 44 in
❑ System presoaked Absorption rate 600+ gpd
(Required if vacant for greater than 30 days prior to Any rejuvenation treatment (past 12 months) No
date of test)
Gallons introduced gallons If yes, enter date N i�
Comments/Deficiencies: `ADDED 730 GALLONS TO DRAINFIELD ON PREVIOUS DAY (3/25/2021).
COSA Checklist yellow sheet
9U
E. SEPARATION DISTANCES PUBLIC WATER
Fromi'Tt a Well on Lot to: (Please enter distances if less than required or if community well)
Septic Tank/Lift Station t > 100' Community Sewer Ma 4eflMleanout > 100'
L if No
Neighboring Tank > 100' ❑ Yes if No
Absorption Field on Lot > 100' ❑ Yes if No
Neighboring Absorption Fields >
Com�"Yes if No
ewerMain'❑ Yes if No
ft ❑ Yes
if No ft
ate Sewer/Septic Line > 25' ❑Yes
if No ft
ft Tank > 100' ❑ Yes
if No ft
Animal Containme _ 0' ❑ Yes
if No ft
ft
ft
Manure/Animal Excreta Storage >
Wells on Adjacent Lots:
ft ❑Yes
i �ft
From Septic/Holding Tank on Lot to: (Please enter distances if less than required)
Building Foundations > 10'
❑ Yes
if No
*51+ ft
Surface Water > 100'
Yes if No ft
Property Line > 5'
Q✓ Yes
if No
ft
Wells on Adjacent Lots:
Wells on Adjacent Lots:
Absorption Field > 5'
Yes
if No
ft
Private Wells > 100'
Yes if No ft
Water Main > 10'✓Q
Yes
if No
ft
Community Wells > 200'✓Q
Yes if No ft
Water Service Line > 10'
Yes
if No
ft
If septic tank is under driveway
comment below
From Absorption Field on Lot to: (Please enter distances if less than required)
Building Foundation > 10'
M
Yes
if No
ft
If absorption field is under driveway comment below
Property Line > 10'
✓v
Yes
if No
ft
Wells on Adjacent Lots:
Water Main > 10'
0
Yes
if No
ft
Private Wells > 100' Yes if No ft
Water Service Line > 10'
❑✓
Yes
if No
ft
Community Wells > 200' Q✓ Yes if No ft
Surface Water > 100'
[]
Yes
if No
ft
F. ENGINEER'S COMMENTS
'MET SEPARATION DISTANCE AT TIME OF INSTALLATION. SEPTIC TANK IS UNDER LOW LYING DECK SUPPORTED BY PIER BLOCKS.
THERE IS NO PIER BLOCKS DIRECTLY OVER TANK. DID NOT INSPECT FCO OR ST1 DUE TO DECK BOARDS FROZEN IN PLACE.
**PER ORIGINAL INSPECTION REPORT AND MICHAEL E. ANDERSON P.E. COSA (10/3/2002).
G. ENGINEER'S CERTIFICATION
l certify that l have determined through field inspections and review
of Municipal records that the above systems are in conformance with
MOA COSA guidelines in effect on this date.
COSA Checklist yellow sheet
#AECC884
0011)
Radlus= 50.00'
Length= 33,50'
Delta= 38.23118'
`
Cord= 32.88'
Cord Dearing= N15'541141W
�f S 86°4235" E
280,60'
,V
12' -- —23.2'
P E L L Y
— CIRCLE
12' w12c_y_Dr"e-
�0 15' Tel & Etec
Easement
C:) See
In Groin of S DETAIL
N
�
136.8'
LOT 19 Grain or
BK 2
352
29.9'
3
DETAIL.
00
(Not To Scate)
o+
o
24.7'
CD
C:)
Z
21'
23.3' 3D'
16.5`
US'
14'
6'
Deck
2 -Story
LEGEND Is'
Frame
QS Septic Vent Pipe 10' 4,5'\-4.
House
6•
Chain Link Fence 4s1/.4,
36'
�-Q Wood Fence
13,5'
34'
, 4F .4
K
`49TH
I hereby certify that I have surveyed tile fol.lou'ing described
. Lot 19, Block 2, Glenn View Estates West Phase 2, Plat
property '
r
No. 2000-89, Anchorage Recording District, and that no encroachments
i �i1(ci1311f r . to Jitcf
exist except as indicated hereon. This As -built will only show the
°, v .. No. 10303
easements that appear on the recorded subdivision plat No. 2000-89,
Anchorage Recording District, under no circumstances should this data
yos s;Qnal �
hereon be used for the construction or establishing of boundary or fence lines.✓
Glenn View Estates West Ph 2
ASBUILT SURVEY
APB Land Surveying
o is so
Lot 19 Block 2
Cordie David J & Cheryl S
SCALE IN F>Er
As Depicted on: Plat No, 2000-89
p
P. 0. Bax 671733
12204 East Prince of Peace Drive
Eagle River, Alaska 99577
Anchorage Recording District
GRID: NW1459
Chu9iack, Alaska 99567
(907) 227-1361
Surveyed: February 3, 2015
na�mm
ateamx
Municipality of Anchorage
On -Site Water & Wastewater Program
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 051-793-36
1. GENERAL INFORMATION
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
Expiration Date: �'I. a -/ 1e
ON a
GLEN N VIEW ESTATES WEST S#2; BLOCK 2, LOT 19
21242 POLLY CIRCLE, CHUGIAK, AK, 99567
DAVID & CHERYL CORDIE
P.O. BOX 671733, CHUGIAK, AK, 99567
Day phone 727-4317
2. TYPE OF DWELLING:
Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or
3. NUMBER OF BEDROOMS:
4. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
•
4
USIVIETTEA
ex)
JUN 1 8 2014
Day phone
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
WaiverNariance request for: N/A
•
Distance: -
Received by-
COSA
y
COSA to be released to the engineer, unless otherwise requested by the engineer.
Date: T"/ Z) ) y
COSA Fee $ 524'
Date of Payment
Receipt Number
COSA #
ob3otG
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179
Address 3701 E. TUDOR ROAD, SUITE 101 *ANCHORAGE, AK, 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, LED. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines 8 Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conations are outside the contral of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
6. DSD SIGNATURE
System #1 Approved for '7" bedrooms.
System #2 Approved for bedrooms.
Disapproved.
Conditional approval for
Date eh eJ'`p
::L�t� ■
•.. ,oy s Lu
- •7
OFESSIaSS♦♦
. ON-SITE i
i.
=Z WATER AND z=
bedrooms, with the following stipulations: WASTEWATER p.
PROGRAM:
sc) RN
By:
Ai • Original Certificate Date: 7- 2 _/ I/
Thenicitybr Arge Develop, emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTCHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
/Paw 1nl191191
Nitrate Advisory
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Ph 2-
Legal Description: GLENN VIEW ESTATES WEST SID *; BLOCK 2, LOT 19 Parcel ID: 051-793-36
A. WELL DATA
Well type If A, B, or C provide PWSID# _ Well Log (Y/N)
Date completed Sanitary seal (Y/N) Wires properly protected (Y/N
Total depth ft. Cased to ft. Casing height (abo - •round) i
FROM WELL LOG AT I CTION
Date of test
Static water level ft. ft.
Well production g.p.m.
WATER SAMPLE RESU
Coliform colonies/100 ml. Nitrate mg./L. Collected by:
nic: ug./L. Date of sample:
`FCO & ST1 ARE UNDER DECK,
Tank Type/Material SEPTIC/STEEL Date installed
Tank size 1250 gal. Number of Compartments 2 Cleanouts (YIN) YES
Foundation cleanout (Y/N) *YES Depression over tank (Y/N)NO High water alarm (Y/N) N/A
Date of pumping (.1 1 (e / / y Pumper ..-5/12
�S
g.p.m.
B. SEPTIC/HOLDING TANK DATA
6/7/2002
C. ABSORPTION FIELD DATA
/'BELOW EXISTING GRADE
Date installed 6/7/2002 Soil rating.p.d./ rft'/bdrm) 0.8
Length 64 ft
Width 3
System type TRENCH
ft. Gravel below pipe 6 ft
Total depth *10.1 ft. Eff. absorption area 768 ft2 Monitoring tube YES
Date of adequacy test 5/22/2014 Results (Pass/Fail) PASS
Fluid depth in absorption field before test 41 in. Water added 610 gal.
Depression over field
NO
For 4 bedrooms
New depth 52 in.
Elapsed Time: 120 min. Final fluid depth 46 in. Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE KNOWN If yes, give date -
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in "Pump off level at
Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service line
wa er alarm level at in.
Meets alarm & circuit requirements?
On adjacent lots
On adjacent lots
PUBLIC WATER
sewer manhole/cleanout
Holding tank
containment areas Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation *51+ Property line 54 Absorption field •*51+
Water main 101+ Water service line 101+ Surface water 1001+
Wells on adjacent lots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 101+ Building foundation 101+ Water main 101+
Water service line 10'+ Surface water 1001+ Driveway, parking/vehicle storage 101+
Curtain drain NONE KNOWN Wells on adjacent lots 2001+
F. COMMENTS
`SEPTIC TANK I5 UNDER DECK. DECK IS SUPPORTED BY PIER BLOCKS. 711 en in 0_101 tr b\ oeK
t3jrec+l i7Ver 1 ren C.
"PER ORIGINAL INSPECTION REPORT AND MICAHEL E. ANDERSON P.E. COSA x10/3/2002) .
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name JEFFREY A. GARNESS
Date &ItrBl1Li
(Rev. 10/12/12)
37
7
•
fill= `
'. aeaaoc�oesoaoosmctc�eau
ieadao :,oao®eoo aea oee
Robert C. Johnson ".
N3 ezJ`3.
-'b
zev
AS -BUILT
i hereby certify that I have surveyed the following described
property. ca'. ? ,
6I,-nnV/-e- S`%cr. Us`i�Pl:cs-e, NO,a,
're. 5• PJ
Anchorage Recording Precinct, Alaska, and that the improve-
ments situated thereon are within the property lines and do not
overlap -or encroach on the property Iymg adjacent thereto, that
no improvements on property lying adjacent thereto encroach
on the premises in question and that there are no roadways; -
transmission lines or other visible easements on said property
except as indicated hereon.
Dated at Eagle River, Alaska
this it day of f" ;1- `• 200
ROBERT C. JOHNSON tC ':
SCALE: Registered -Land Surveyor No.880-LS
1" -1., Box 77-0456, Eagle River, Alaska 99577
Phone (907) 6942543
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.O. 051.793.36
HAA# HA 02.0 5-1.2_
Expiration Date: 10 - 3 - 0 3
1. GENERAL INFORMATION
Complete legal description Lot 19, Block 2. Glennview Estates West Subdivision Phase II
Location (site address or directions) Polly Circle
Current Property owner(s) MM&M Contracting, Inc.
Mailing address P.O. Box 670495 Chugiak. AK 99567
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: Four(4)
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
Day phone 688.1236
Day phone
Day phone
TYPE OF WASTEWATER DISPOSAL:
❑ Individual On-site
❑ Individual Holding tank ❑
❑ Community On-site 0
® Public Sewer ❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with
new water sample results Tess than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public
water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional
engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. 1 further verify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm Anderson Engineering
Address P.O. Box 240773 Anchorage. AK 99524
Engineer's Printed Name Michael E. Anderson. P.E.
Phone 522.7773
Date 9/27/2002
5. DSD SIGNATURE 'rss'Z • Cz I
,•
Approved for bedrooms. '; ?20;fsjp<<<�'
Disapproved. -
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
By:
(Rev. 12/00)
X
.e// /C% / o-A"fr
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: / 0 - 3 - D
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South Bragaw SI.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Lot 19. Block 2. Glenn New Estates West Phase 1I
A. WELL DATA
Well type AWWU
Date completed
Total depth ft.
N A, B, or C provide PWSID #
Sanitary seal (YIN)
Cased to ft.
FROM WELL LOG
Date of test
Static water level
Well production
WATER SAMPLE RESULTS:
Coliform colonies/100 mi.
Date of sample:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel
Tank size 1.50 gal.
Foundation cleanout (Y/N) Y
Date of pumping
C. ABSORPTION FIELD DATA
Date installed 6/7/2002 Soil rating (g.p.d.Mt2 or ft2/bdrm) .8 GPD/SF System type Deep Trench
ft.
g.p.m.
Nitrate mg./I.
Collected by:
Number of Compartments 2
Depression over tank (Y/N) N
Pumper Recent Construction
0
Parcel ID: 051.793.36
Well Log (Y/N)
Wires properly protected (Y/N)
Casing height (above ground) in.
AT INSPECTION
ft.
g.p.m.
Other bacteria colonies/100 mi.
Date installed 6/712002
Cleanouts (Y/N) Y
High water alarm (Y/N) N
Length 64 ft. Width 3 ft.
Gravel below pipe 6
ft.
Total depth 10 ft. Eff. absorption area 768 ft' Monitoring tube Y Depression over field N
Date of adequacy test Results (Pass/Fail) For _ bedrooms
Fluid depth in absorption field before test
in. Water added_ gal.
Elapsed Time: _ min. Final fluid depth _ in.
Any rejuvenation treatment (past 12 mo.) (YM & type) N
New depth_ in.
Absorption rate >_
If yes, give date
g.p.d.
D. LIFT STATION
Date installed Size in gallons
"Pump on" level at _ in. "Pump off' level at in.
Datum Cycles tested
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankAift station on lot
Absorption field on lot
Public sewer main
Sewer /septic service line
Manhole/Access (Y/N)
High water alarm level at in.
Meets alarm & circuit requirements?
On adjacent lots
On adjacent lots
Public sewer manhole/deanout
Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >S
Water main N/A Water service line >10'
Wells on adjacent lots »EO' r Wei
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 5'
Water Service line >10'
Curtain drain None Noted
F. COMMENTS
G. ENGINEER'S CERTIFICATION
Building foundation >10'
Surface water >100'
Wells on adjacent lots >200'
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA HM guidelines in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 912712002
Absorption field >5'
Surface water >100'
Water main >10'
Driveway, parking/vehicle storage >10'
HAA Fee $ 3 7 c 4 Waiver Fee $
Date of Payment 912 7/62 Date of Payment
Receipt Number 02.42.21 Receipt Number
(Rev. 12/00)