On -Site Water and Wastewater Program, 4700 South Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 3
www.ci.anchorage.ak.us (907) 3437904
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number. SW SW020202 PID Number: 020-172-08
Hone:
Rusty Becker Wastewater System: ❑New ®Upgrade
901 Mt Sida villp9e nrive, 99516 ABSORPTION FIELD
Phots: rwleer of 9edoome:
345-9R42 4 ® Deep Trend) ❑ shell"Trench p Bed o Maid o DOW.
LEGAL DESCRIPTION Sol paling: Total Depth "m wonal pada:
1.2 nmr? 9 Fr
Mork: I.M. SIAtiNalon: Depth to post bottom hon or" Waft: Grant depth beneath pipe:
4 1 Mt. Side Village 2.5 n 6.5 n
TW Wap: Renge: SeNal: Fd added abM glom pude: Gavel Length:
1 Ft. 4 Fr.
Well: ❑ New El Upgrade Gavel a+oh: lancer of wee: Pstanca beneeerl knee:
3 Ff. 1 0 n
Oesrhuarl (Pnvre. A B.4I TotalDeptm Cased lo: Tali abeonpeom erect: Pipe Mot":
Fl.I FI 520 Ft F810/3034PVC
Dnnr. Date Drilled:Static Wis levN: waUW .. Data lnsMlled:
Ft A+ Home Services 7/23/2002
Yield: I Piny Ben k I calling Hollisove Grand: TANK
GPM FI, n.
SEPARATION DISTANCES ❑ Septic ❑ Holding ® S.T.E.P. ❑ Other.
To Septic Absorption Lift Holding %biicrPrlrale M°'xdadt' capal w.
From Tank Field Station Tank Se Llne AnehTank 1250Gr.
was 127 137 136 110 MakvW. Wnibar of Canpammnl4
steel 1 2
s.Wcewalen 100+ 100+ 100+ LIFT STATION
Size:
Lotune 54 68.6 45 250 Gal Oro/Anch Tank
Foundation 44 17.6 30 Tp^en on' kr`sl M In at -"dr"at I Wgh wren ahamM
M.
Q.t.n Darn 100+ 100+ 100+ Pump Make a Mods aed Tical Mspeo "Wored br:
MOA
R 'viru: BENCH MARK
LaodM and Descnwon:
Front Porch
Inspections performed by: Pannone Enq. Svc Dates: 1"7/2312002
2nd07/24/2002
Department of Health and Hju�n)an Services approval
Reviewed and approved by: �f`!► Date: I IIICL
(iev.1111N) 1 I
Assumed Eon aacn:
100.0 FL
Engineer's Stamp
PERMIT NO, SW020202 AS -BUILT P.I.D. NOo 020-172-08
WASTEWATER DISPOSAL SYSTEM
LOT 1, BLOCK 4 MOUNTAIN SIDE VILLAGE S/D
NO WELLS OR SEPTIC 4/
W/IV 200' 3F PROPOSED�Lj~
ti
�0
NSTALLED FVM
ISTALL BA _L -TY
3-W VAL
_.._ST'G D INFIELI
98% US D. TO
REUS I
E STZ
wl
EPTIC T
N IN PL
X20%
TOP OF—
TER-
----.EXIST'G
WELL
Fl\Work\7RAW ING\ _—4MOL$gTA
SWING TIES
CO A B
FC 28.7 2.0
T1 44.1 21.5
T2 48.3 28.6
LS 49.6 30.5
MT 35.5 33.5
NO WELLS OR SEPTf
W/IN 200' OF PROP❑
SYSTEM.
f REPLACEMENT FIELD
IDEx4OLFx6.5'ef.
ANEW 1500g
•6 S.T.E.P. TANK
EXIST'G 4BR
SHOUSE
i )
PREPARED FOR,
Rusty Becker
17901 Mt. Side Village Drive
Anchorage, AK 99516
345-2892
NO WELLS OR SEPTIC
W/IN 200' OF PROPOSED
,SYSTEM.
AS—BUILT,
PERC RATE= 3 MIN/INCH
125 SF/BR, 4 BR HOUSE
500 SF REQUIRED
DEEP TRENCH, 6.5' EFF.
40LFx 3',
9' TOTAL DEPTH
TOTAL AREA=520 SF
1500g S.T.E.P. TANK
PANNONE ENG. SVC, LLC
P. O. BOX 102954
ANCHORAGE, ALASKA 99510
227-3522 P, 272-8218 Fax
DATEo 8-14-02I AS -BUILT
SCALEt 1'=50'
PERMIT NO, SW020202 AS -BUILT DETAILS P.I.D. NO, 020-172-08
WASTEWATER ABSORPTION SYSTEM
LOT 1, BLOCK 4 MOUNTAIN SIDE VILLAGE S/D
NOTEI
1) ALLWORK WAS BE PERFORMED
IN ACCORDANCE WITH, & ALL METERIALS 0 00
SHALL CONFORM TO AMC15.65. 16 0;
2) SEE GENERAL NOTES ON SHEET 1. 0 0)
3) ADDED A MINIMUM OF I' OF FILL OVER lna NY313
ENTIRE TRENCH.;:;:;t;
49TM ';1}
Y
d
f
d
O
'•'•'•'
f
3anl 8011NON
I
_a
u a.
s
Z
C
o
O
O L
5�
K
H
N
I` Ca
c
I—
LN
W
i
U
H
[i
Ld
t` M
1n0 NV313
cq
CV)
a)
OL
•6
0�
T
CO
Ib
V.5�
Q
0
6.5'
CoC30
1
�
I
49TM ';1}
Y
d
f
1110 NW313
1n0 NV313
1n0 NY313
NauVaNnO!
0 Cc\Work\DRAWING\1-4MOUNTAINSIDEVILLAGE.DWG
ff PREPARED FORT Pannone Eng. Svc., LLC
CE 814gnnone;Am Rusty Becker P. 0. BOX 102954
.���i 17901 Mt. Side Vittage Drive ANCHORAGE, ALASKA 99510
'' `<%� Anchorage, AK 99516 272-8218, PHONE & FAX
345-2892 DATEt 8-14-02
NOT TO SCALEI AS—BUILT
J
O
'•'•'•'
f
3anl 8011NON
I
5�
N
W
H
1n0 NV313
CV)
a)
OL
•6
0�
T
CO
1110 NW313
1n0 NV313
1n0 NY313
NauVaNnO!
0 Cc\Work\DRAWING\1-4MOUNTAINSIDEVILLAGE.DWG
ff PREPARED FORT Pannone Eng. Svc., LLC
CE 814gnnone;Am Rusty Becker P. 0. BOX 102954
.���i 17901 Mt. Side Vittage Drive ANCHORAGE, ALASKA 99510
'' `<%� Anchorage, AK 99516 272-8218, PHONE & FAX
345-2892 DATEt 8-14-02
NOT TO SCALEI AS—BUILT
07/28/2002 11:10
M 907S888770
.fir Home Services,
Inc.
®001
i JU6-23-2002 06167 AN FDO. GLGCTRSC
/---Rwb
272 4690
r.OL
sra'Ar .
7/23/2002
SUO PAGE 1/1
RLSLLtFAX
inspection Report
Munlc"ntr of Anchorage, SuNing Satrti Dtvlalon
4700.0outh Srapaw
InSP'SCT:OPh VCM 346-8300 :► E XUQAe PA7C (eo7)s4a-ms XMFM 3434MIL
name EDW ELECTRIC ParmM 02-4730
AedreW 1790L MOUNT INME pool 272-4591
MAGE DR
Lapel 69 4 LT 1 Lrup Man Dole 7/24/2002 AM
Suamvldon MOUNTAMSMevnLAae
Cornrne s Or Opeotlorrs
AM U1SP/ CALL PMFLTO INSPECTION TO MEET
Irapactlon Retro eklmico1 Ndwpw.thm N
NO NONCOMPLEM M OE6MM
❑ COMMCMNS ESSENTULAS EXPLAINED BELOW
WILL RE-EXAMDIE AT NEXT DO NOT CONCEAL UN M Re7NSPECTION
C3 WILL
C)
COMFUM I sI (for kepcew use ony)
Str���� S.�rTlrh Q.6f,ro0CA.V�i/
(/,/DA Y. Cid.
7 2y
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water 8 Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Jul 02, 2002
Expiration Date: Jul 02, 2003
Permit Number: SW020202 Parcel ID: 020-172-08
Legal Description: MOUNTAINSIDE VILLAGE BLK 4 LT 1
Design Engineer. 0062 Pannone Engineering Services Site Address: 017901 MOUNTAINSIDE VILLAGE DR
Owner Name: Rusty Becker Lot Size: 142181 SQ. FT.
Owner Address: 17901 MOUNTAINSIDE VILLAGE DR Total Bedrooms: 4 Permit Bedrooms: 4
ANCHORAGE. AK 99516-5735
This permit is for the construction of:
❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations (18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
7//5-102 EAiG. CALL £O ; fe-/3pTs ra Pu T 07191vFICG 0 i�DCr_✓' �r�l
of sfwflQ Rdcl< 4 19`00 (,ALGoN
11-///n
Received By: ?Qr_A Q4'1c� _
Issued By:V .. ln'�.
Date: 7/Z/OZ--
Date: 7/2/02
Municipality of Anchorage
-- Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 995196650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020.172.08 Permit Number SW02020Z
Property owners) Rusty Becker Day phone 345.2892
Mailing address (1)17901 Mt. Side Villaqe Dr.
Mailing address (2) Anchorage, AK Zip Code 99516
Legal description (Lot, Block & Sub'd.) Lot 1, Block 4 Mt. Side Village
Legal description (Section, Township & Range)
Lot Size'A /1"M,1?/ Acres! q.Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only
❑
Well Only
❑
Sewer and Well
❑
Water Storage
❑
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
❑
Jacuzzi
❑
Swimming Pool
❑
Water Softening Unit
❑
Therapy Pool
❑
I certify that the above information is correct. 1 further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
5�
(Signature of property owner or authorized agent)
Permit Fees: L',()oCU
/
Date of Payment: tD I P-$/ ca
Receipt Number. 317 7 S 54
(Rev. 12100)
Waiver Fees:
Date of Payment:
Receipt Number.
Pannone Engineering Services, LLC
Consulting Engineers
(907) 272-8218
June 23, 2002
Municipality of Anchorage
Development Services Department
On -Site Water 8s Wastewater Program
4700 S. Bragaw Street
P. O. Box 196650
Anchorage, Alaska 99519
Subject: Lot 1, Block 4 ML Side Village S/D
Septic System Replacement Permit Request
Gentlemen:
P.O. Box 102954
Anchorage, Alaska, 99510
(907) 272-8218 Fax
My firm was contacted to a Health Authority Approval of the septic system serving this lot The
existing Trench was found to be 98% saturated. The system past an adequacy investigation on
May 15, 2002. I informed the new and old owner the system should be upgraded. I was
authorized by the new owner to upgrade the system. A single test hole was excavated on June
1, 2002 on the lot The soils report and a percolation test result is attached. Ground water was
monitored for seven days. No bedrock was encountered in the test hole. Ground water was not
encountered. Seeps were noted at a depth of fifteen feet This depth will be used for the design
water table.
The lot is approximately 135217 square feet in size. Lot 1 slopes to the west at approximately 1-
2 percent in the area of the test holes, and then steepens to approximately 15 percent on the
western portion of the lot The existing septic tank is suspected to be in failure and will be
replaced with a new deep burial 1250g septic tank. The proposed installation will be located on
the western portion of the lot. The lot is served by a private well. The proposed location is
greater than 100 feet away from existing & neighboring wells and 25 feet from the water service
lines. The surrounding wells are located greater than 200 feet from the proposed installation.
The proposed installation will not affect the future development of the surrounding or existing
lots. See the attached design.
If you have any questions or concerns, please contact me at 227-3522 or 272-8218.
Sincerely,
I
teven R. Pa one, P.E.
Civil Engineer �J
Attachments:
Q\Work\Letters\1-4 Mt Side Village.001.doc
n'H
....
�F55kQ ..
0
PERMIT NO, DESIGN P.I.D. NOo 020-172-08
WASTEWATER DISPOSAL SYSTEM
LOT 1, BLOCK 4 MOUNTAIN SIDE VILLAGE S/D
� l7
V NO WELLS OR SEPTIC
�~ W/IN 200' OF PROPOSED
SYSTEM.
z
NO WELLS OR EPTIC
W/IN 200' OF RO71,NSTALL
D
SYSTEM.
eF/OWSPJ
INSTALL BAXL-TYPE
3-W VALV
EXIST'G D INFIEL
98% US D. TO
REUS D.
,v
N �1
W�
E ST' 250g
EPTIC TA -
ABA ON IN PLAC
,---pay
TOP OF
SLOPE
OF
3SED REPLACEMENT FIELD
TRENCHES, 5'WIDEx45LFxl'ef.
PROPOSED DEEP BURIAL
12508 SEPTIC TANK
EXIST'G 4BR
/-HOUSE
1
NO WELLS OR SEPTIC
W/IN 200' OF PROPOSED
SYSTEM.
DESIGN,
J PERC RATE= 3 MIN/INCH
/ 125 SF/BR, 4 BR HOUSE
500 SF REQUIRED
5 -WIDE DRAINFIELD SYS, 1.0' EFF.
REDUCTION FACTOR = 0.87
TWO TRENCHES 45LFx 5',
9' TOTAL DEPTH
TOTAL AREA=450 SF
DEEP BURIAL SEPTIC TANK
PREPARED FOR,
Rusty Becker
17901 Mt. Side Village Drive
Anchorage, AK 99516
345-2892
PANNONE ENG. SVC, LLC
P. O. BOX 102954
ANCHORAGE, ALASKA 99510
227-3522 P, 272-8218 Fax
DATE, 6-23-02I DESIGN
SCALFe 1'=60'
PERMIT NO, nc,�Trr\l nPTAILS
WASTEWATER ABSORPTION SYSTEM
LOT 1, BLOCK 4 MOUNTAIN SIDE VILLAGE S/D
NOTE,
1) ALLWORK SHALL BE PERFORMED
IN ACCORDANCE WITH, & ALL METERIALS
SHALL CONFORM TO AMC15.65.
2) SEE GENERAL NOTES ON SHEET 1.
3) ADD A MINIMUM OF 1' OF FILL OVER
ENTIRE TRENCH.
4) INSULATE DRAINFIELD WITH 4- RIGID
INSULATION WHERE IT CROSSES THE
DRIVEWAY.
5) RESERVE DRAINFIELD IDENTICAL TO
ORIGINAL WITH 10' SEPARATION TO
ORIGINAL DRAINFIELD.
6) rESERVE FIELD MAY BE INSTALLED AT
SAME TIME AS ORIGINAL FIELD.
I
x S'
1, Y Z
a0
° 0C ,---1
'. c c 10' F—
° ° U
a a U
4 :' i N
7.s• —1'—
� 3
O 13
R.
P.I.D. NO, 020-172-08
LM NV313
•••
38(11 wIINON
tt
CC
t
,�y33 u
N
1(10 Nv313
I
N
,n 00 NV3V
1
1(10 NV3V
1r10 NW313
NOILvaNr10!
W
J
C3
CL
G\Work\DRAWING\1-4MOUNTAINSIDEVILLAGE.DWG
PREPARED FOR, Pannone Eng. Svc., LLC
49 Rusty Becker
17901 Mt. Side Village Drive
Anchorage, AK 99516
c1c1�� 345-2892
P. O. BOX 102954
ANCHORAGE, ALASKA 99510
272-8218, PHONE & FAX
DATE, 6-23-02 DESIGN
NOT TO SCALE
W= Ras - McmD0l&uWm 7=
PANNONE ENGINEERING SERVICES
P.O. BOX 102954
ANCHORA03E.AK99510
On 272-8218
DRIEDFOR: Rwb'Bo*w DATEPBRFORIWD:6-01-01
FOAL DEampnom.- lm 1. Bladt 4 Yt aide VGlxw 8/D
Tib[ HO1Z 1OR Onpalo-
Roa MA"
1
2-
3— we80tlaQ
ow ands a Band
4-
3—
—
3— mm HOLT
6-
7—
a-
9-
10-
11
-
7—
a-
9-
10 -
11 —
12 —
13 —
14 —
IS —
16 —
17 —
18 —
19 —
90 —
WAS GROUND WATER KDM
ZNOOUNTZRZD? No 7= IOU
IF YES. AT WHAT
BOLI DEPfW 4) -
DEPTH TO WATER AP71ER
HONIIOR ING? -0-
DATE: 673-01
1RADDId nm 0aeaa aR ne"ar Now
Tom Tam WATU Imm
6-1-02 1%36 6• --
1%46 10 2 11/16' 3 5/16•
1%46 -- 6 3/W ----
19-56 10 3 1/16• 3 5/16•
1936 -- 61/4- ---
2006 10 2 15/16• 3 5/16•
PEROIATION RATE 3tmin/hwhl PBRC HOLE DU=%R 6 bwhw
TEST RUN BZW ERN 8 I and 9 FT
CO)ndW Teat bole esesvated by A+ Home Setvica. Tat hole was pceBoalmd before peen test.
PERFORMD BY: Steven R. Pannone, P.E. I CERTIFY THAT THIS TEST WAS PERFORWM IN ACCORDANCE
WITH ALL STATE AND W UNICIPAL OUMLINE8 IN EFFECT ON THE DATE OF TWS TEST.
GRE. ..R ANCHORAGE AREA BO(H
yri Department of Environmental Quality
9`'°"` 3330 C Street
Anchorage, Alaska 99503
INSPECTION_ REPORT ON-SITE IJ
C!�ryCC SEWAGE DISPOSAL SYSTE�/M 7
NAME �'� MAILING ADDRESS__JP j �1
�Sj `�_0 PHONE
LOCATION�LEGAL DESCRIPTION !v�4
SEPTIC TANK:
DISTANCE / NUMBER OF /
FROM WELL `d3 MANUFACTURER A�A MATE RIAL-COMPARTMENTS
/r>
INSIDE LENGTH INSIDE WIDTH LIQUID DEPTH LIQUID CAPACITY ,;Z- GALLONS.
TILE DRAIN FIELD: // 0'eAk0
'r TOTAL LENGTH G
DISTANCE FROM WELL FOUNDATION NEAREST LOT LINETOF LINES 1!�
NUMBER OF LINES _ DISTANCE BETWEEN LINES -TRENCH DF N. TOTAL EFFECTIVE
ABSORPTION AREA
SQ. FT. LENGTH OF EACH LINE -
d DEPTH OF FILTER
DEPTH: TOP OF TILE TO FINISH GRADE ZZ. MATERIAL BENEATH TILE ___--IN. ABOVE TILE ___ IN.
WELL:
a/) �/
TYPE V1 //PCONST RUCTION
BUILDING NEAREST
FOUNDATION LOT LINE
CESSPOOL
APPROVED _
DISTANCES: - _ -
OTHER SOURCES
DISAPPROVED-___
INSTALLED BY: 6E 4
SEWER LINE DEPTH:
PIPE MATERIAL:
LOT SLOPE:
REMARKS
Form EQ -032
NEAREST SEPTIC
SEWER LINE TANK _
REMARKS
DEPTH
SEEPAGE
SYSTEM -
DIAGRAM OF SYSTEM
DATE L _ APPROVED
W v
G.A.A.B.
DISTANCE FROM:
17,5-
iso.
otc
PLHORAGE AREA BOR 'F1PERMIT NO.DEPARTMENT OF ENVIRONMENTAL QUALITY3330 '•C'• STREET ANCHORAGE, ALASKA 99503TELEPHONE 274-4561 SEWAGE DISPOSAL SYSTEM -- APPLICATION A14D PERMIT �^J��/7- MAILING ADDRESS ONE
NAME OF APPLICANT
_—u"_as
INSTALLATION LOCATION/) �"�/ /}
LEGAL DESCRIPTION !�/�• f �/ / �/`�
INSTALLATION OF: SEPTIC TANK %< SEEPAGE PIT %f `- DRAIN FIELD -. OTHER
TYPE AND SIZE OF FACILITY TO 13E SERVED
FINANCED THROUGH
--- TO BE INSTALLED BY
_ NOTE: THIS PERMIT IS NOT VALID WITHOU SOIL T ST
SOIL TEST RESULTS � /�///y��� rrr////•/
COMPLETION DATE ANTICIPATED r St'c /yn`�=--'
FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE
DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION.
SEPTIC TAMC SIZE -,/
TYPE SEEPAGE AREA SIZE /.Y!-D'Ll/ TYPE -
,h�nn� Lv uP�
MINIMUM DISTANCES, REQUIRE% ENTS DIAGRAM OF SYSTEM
FOUNDATION TO SEPTIC TAMC -- -ry
FOUNDATION TO SEEPAGE PIT
SEPTIC TANK TO SEEPAGE PIT WALL
SEPTIC TANK •� SEEPAGE PIT _ J DmAi W-7tPE6.D -�
TO NEAREST LOT LINE.
WEL�.J9O_5EPTIC TANK �u-0 SEEPAGE P{T
ALSO CONSIDER AREA WELLS.
WATER MAIN TO SEPTIC TANK
DRAIN FIELD �� -
c
SEEPAGE PIT - / G� DRAIN-PiELO
SEEPAGE PIT /
SEPTIC TANK, /&to
TO RIVER, LAKE. STREAM.
CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP OF
EXCAVATION 5 FEET INTO UNDISTURBED SOIL.
4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT
FITTED WITH AIRTIGHT REMOVABLE CAPS.
GRAVEL BACK FILL - �=•-5�1�-f'C4�f� � � �� i���-�-�-Q� 2D-C.�
CONFORM TO BOROUGH REGULATIONS REGARDING INSTALLATION.
G.A.A.B.
OR
LICENSED DESIGNER
d x _ 4m,14
I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO. 28-66 AND THAT THE ABOVE
DESCRIBED SYSTEM IS IN ACCORDANCE WITH SAID CODE. I also certify that this home will contain a maximum of 4
bedroo s. ,understand an upgrade wqW_be necegrshd more bedrooms be added.
DATE -� APPLICANT'S SIGNATURE ---
FORM NO. CO -016
cNND
GREATEN ANCIIGRAU APP A eoROUl111
Department of Div ironmental Quality
3330 "C" Street.
Anchorage, Alaska 99503
SOILSLO(; PliROI, t1'IO1v 7'1?:,'I
,
Performed for���t Pcrior);;t_
Legal Description:
This form reports: sods log ,� _ ----V—___--- Percolation hest—__ --
Depth
Feet
6
r'r�li /iz'.�lJ _
7
13 - `!
S
7opo
Was ground water encountered? (l _ If ves , at what depth?
Reading
Date
Gross Time
Net Time
4
Was ground water encountered? (l _ If ves , at what depth?
Reading
Date
Gross Time
Net Time
Depth to Water Net Jroh
--------cola----
Pertion rateminute.
Proposed installat n Seepage Pit _ Drain Hold
Uepth of Inlet _ Depth. to Bottom of pit or tretic i
X�
Performed By: / y e;,c_�-1�r� ��_ Certified --
1 J r\ n A n , C/ 7 A 1
kNCIIORAGE
FAIRBANKS
(:ONSUL'I'X-N'I'y, LN(- Ju[VIsAu
249 EAST 51ST AVENUE • P. O. BOX 6007 ^ ANCHORAGE. ALASKA 99503 ^ TELEPHONE 907-279-0463 • TELEX 090-35419
July 14, 1975
Mr. Dan Roger
Star Route A
Box 1585 F
Anchorage, Alaska 99507
R & M No. 562060
RE: Test Hole and Soil Log Report for Sanitary System
North East Corner Section 11, T.11 N., R. 3 W., SM
Dear Mr. Rogers:
We are submitting herewith the test boring results and our comments regarding
soil conditions encountered at the subject site. This investigation was per-
formed in accordance with your request of July 11, 1975 and those procedures
outlined in a letter dated December 19, 1974 by Mr. Rolf Strickland of the
Greater Anchorage Area Borough Department of Environmental. quality.
A single test hole was put down within the building site area for the purpose
of defining general subsurface soil conditions for the proposed sanitary
system. Excavation was accomplished with a tractor -mounted backhoe and the
test hole was extended to a total depth of 14.0 feet below ground surface.
The final log prepared for the test hole has been included in Drawing A-01.
Ground water was not encountered in the test hole.
We appreciate being given this opportunity to be of service to you. Should
you have any questions with regard to the above, please do not hesitate to
contact us.
very truly yours,
R & M CONSULTANTS, INC.
(Jk) ...y�.1
James W. Roone,
vice President
JWR/ja
xc: GAAB
I
cCa' Gc 6 4p/
I
td
�Sjv
SRP
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw Street
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 020-172-08 HAA #
Expiration Date:Z-
1. GENERAL INFORMATION
Complete legal description Lot 1 Block 4 Mountainside Village
Location (site address or directions) 17901 Mountainside Village Dr., Anchorage, AK 99516
Current Property owner(s) Helen Rogers Day phone 345-2289
Mailing address I 17901 Mountainside Village Dr Anchorage, AK 99516
Lending agency. ' Day phone
' - Mailing address
Real Estate Agent Beckie Brocies/Dynamic Prop Day phone 261-7546
Mailing Address 3111 C Street Anchorage AK 99503
Unless otherwise requested, HAA will be held by DHHS for pickup. HAA picked up by:
',.'2.- NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well ® Individual On-site
Individual Water Storage ❑ Individual Holding tank ❑
Community Class Well ❑ Community On-site ❑
Public Water System ❑ Public Sewer ❑
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except between spouses) on properties served by a single family on -she wastewater disposal and/or water
supply system. DSD also Issues HAAs upon request to home owners. Certificates of Health Authority Approval are
valid for 90 days from the date of Issue for properties served by a private or Class C well and maybe reissued with
new water sample results less than 30 days old. Certificates are valid for one year for properties served by Class A
or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
(R...111M
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation
based on procedures outlined in the Health Authority Approval Guidelines for this Health Authority Approval
application shows that the on-site water supply and/or wastewater disposal system is safe, functional and .
adequate for the number of bedrooms and type of structure Indicated herein. I further verify that based on the
Information obtained from the Municipality of Anchorage files and from my Investigation and Inspection, the
on-site water supply and/or wastewater disposal system is In compliance with all applicable Municipal and
State codes, ordinances, and regulations in effect at the time of Installation-
Name of Firm Pannone Eng. Svc. Phone 272218
Address P.O. Box 102954. A_nch, AK 99510
Engineer's Printed Name Steven R. Pannone, P.E. Date Co1049Z
Engineers Comments: In conducting an adequacy test, I attempt to provide a thorough, conscientious �*%"W1k1k1LV1%�
engineering analysis of the system in accordance with MOA DSD Guidelines & • � �♦
reported results describe the performance of the Regulations. The P��..»». ♦1�
system tinder the conditions encountered at the time of W •�'••
r'
the test, and separation distances measured to readily identifiable features. The operational life of all i �'J,.•°
wells and septic systems depend on the local soil condition, ground water levels that may fluctuate "
.during the year, and the water usage of the family being served by the system. These conditions are � 49-
m ' � ••• t �
outside the control of the evaluator of this systeAll systems eventually fat? and satisfactory test M~
results do not guamntx-future performance of the system, nor do they guarantee that there are no .. »»» »•».»..� »
hidden defects or encroachments. PPS can therefore not provide any warranty for future performance ♦ � Steven R.••Pannone:
nor give any estimate of how long the system will continue to meet the operational requirements of the _ �j No. CE 8149 Ai
ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Anp.. ♦j S i�
reliance nponor use of this report by any other Person or party is not authorized nor will it confer any
♦ �4•Z�� • v��
legal right whatsoever:
6.: DSD SIGNATURE; ♦♦ha,�� ��
Approved for L� bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist X Maintenance Agreements
Septic System Advisory �`L Supplemental Engineer's Report
Well Flow Advisory Other
By: / l / " Original Certificate Date: �e -
Expiration Date: Reissue Date:
ma.111M
Municipality of Anchorage
• Development Services Department
Building Safety Division
On -She Water and Wastewater Program
4700 South Bragaw Street
P.O. Box 198850 Anchorage, AK 99519-6850
www.ci.anchorage.ak.us
(907)343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Lot 1 Block 4 Mountainside Village Parcel I.D.: 020-172-08
A. WELL DATA
Well type P
Date completed
Total depth 105' ft
Date of test
Static water level
Well production
If A. B, or C provide PWSID #
Sanitary seal v_
Cased to 40'+ ft
FROM WELL LOG
WATER SAMPLE RESULTS:
ril
Well Log r1'.
Wires properly protected Y
Casing height (above ground)IV' in.
AT INSPECTION
8N812002
10' ft
9 -p.m 3.0+ 9 -p.m
Coliform ,_9 _colonies/100 ml Nitrate 1.29 mQA Other bacteria 0 colonies/100 ml
Date of sample: 5/1512002 Collected by: Laura Pannone
B. SEPTICMOLDING TANK DATA
Tank Type/Material Greer Steel
Date installed $10197 Tank size 1250 gal Number of Compartments 1
Cleanouls Y Foundation cleanout Y Depression over tank N High water alarm N/A
Date of pumping 711912001 Pumper A+ Home Services
C. ABSORPTION FIELD DATA
Date installed108 1978 Soil rating (g.p.d.W or ft�/bdrn) 178 System type Trench
Length _0 --ft . Width 3 It Gravel below pipe 8' It
Total depth 13— ft Effective absorption area M0 to Monitoring tube Y Depression over field N
Date of adequacy test1¢/ 512002 Results (PasslFail) P For!j bedrooms
Fluid depth in absorption field before test $4 in Water added618 gal. New depthM in.
Elapsed Time:.Q min Final fluid depth 994 in Absorption rate >= 600+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (YM & type) N If yes, give date
(Rev. 11AM
D. LIFT STATION
Date installed a allot
'Pump on' level at _ in'P p o level at
Datum Cycles t ed
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Manhole/Access
in High water alar level at __ in
Meets alarm & circuit requirements?
Septic tankAitt station on lot 100'+ On adjacent lots 100'+
Absorption field on lot 100____ On adjacent lots 1001+
Public sewer main 25'+ Public sewer manhole/cleanout 100'+
Sewer /septic service line _ 25'+ Holding tank 1009+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 0' Property line 68
Absorption field 12'
Water main 25'+ Water service line _25'+ Surface water 100'+
Drainage 100'+ Wells on adjacent lots 01+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 95' Building foundation 16' Water main 211
Water Service line 5'+ Surface water _100'+
Driveway, parkinglvehicle storage 211
Curtain drainnc100'+ Wells on adjacent lots 1000+ AA
F. COMMENTS tl 1(?gjalled P� ��7J b� s7U4t�(5-AbclAt �Il/Qr�4ivtc. �r�lz�r(
1050. nteowred 1D 90" w/s1odye,cl� b�*, m�.CU� � 0et1'� �0" 5ys�ti�
o 'ILZ _ in Qs .• ...��
G. ENGINEER' t FR"CIf4eTIIml 0 r r ;..„,__
i qtr yy�
l c&ft that I have delarmined through field inspections and i . 49TH i
review o/Municipal records that the above systems are In
conftmume with MOA HAA guidelines in effect on this date.
w—
Engineer's Printed Name Steven RPannone P E �� CSteven R. Hcnnone
No. CE 8149 r��
Date to 7- ����J2oL�i�'�'�
HAA Fee a -3350'
Waiver Fee $_
Date of Payment _ D �� Date of Payment
Receipt Number a 0 $ Receipt Number
(Rev. 1 UAB) '
MUNICIPALITY OF ANCHORAGE
M E M O R A N D U M
SEPTIC SYSTEM ADVISORY
HEALTH AUTHORITY APPROVAL NO. .02-0 et- q y
Prior to a recent adequacy test on the septic system for
this lot, C14 inches of standing water was observed in
the absorption field. This indicates that approximately
�8 of the absorption area is inundated. Although
this system passed the adequacy test, the remaining life
expectancy may be limited.
This advisory must be attached to all copies of the subject
Health Authority Approval.
YAY-17-OZ 04:45PY FR*a&E ENVIRNERAL SRV
CTO Emlro~tBl Swvlcw Inc.
• YMNrr'rrrwrrrrrr�
8075615301 7-830 P.OZ/03 F-345
CT&I JWV
102239.7001
A9IW WTbwe am Alar4a Sombrd Time
CBaat Name
Pamome Eb&. Srv.
Prated Dae/rime
03/17/2002 10:48
Pmieet Namalf
Lt I Dk 4 MomWaside V171aae
COReated Do WTlme
05'13/2002 13AS
CBrmtSamplelD
O/SHoambib
Rare(VadDOWTIms
05115/2002 1435
D1aa1s
Drt&4 Water
Tachakal Dlreaor
de
° ° �'
Rdr4rra ar
PWSCD
0
Semple Re'rarks
ARuweb:e Rep Anlyar
Prm=pm
Raulu
POL Wei Method Lima:
Daft Ove Mi:
Slater& Department
Niema-h
129
0.200 myL EPA 300.0 (<10)
0311S/02 MT
laior9blology
Laboratory
TomlCoufo'm
0
eoV100mL SM189222B (e1)
05115m KAP
P.
W
N B9059'1 O°E 363.00'
THE INFORMATION HEREON IS FOR THE USE OF LENDING INSTITUTIONS SPECIFICALLY TO SHOW ANY CONFLICTS BETWEEN
EXISTING STRUCTURES AND PLATTED LOT LINES OR EASEMENTS AND IS NOT TO BE USED FOR POSITIONING ADDITIONAL
STRUCTURES OR FENCELINES.
EASEMENTS OF RECORD, OTHER THAN THOSE SHOWN ON THE RECORDED PLAT, ARE NOT SHOWN HEREON.
NOTE: ANY FENCELINES SHOWN ARE LOCATED APPROXIMATELY AND ARE NOT TO BE USED TO DETERMINE PROPERTY LINES
OR LOCATE STRUCTURES.
AS -BUILT SURVEY
NO CORNERS SET THIS DATE SCALER" = 40'
I HEREBY CERTIFY THAT I HAVE PERFORMED A
MORTGAGEE'S INSPECTION OF THE FOLLOWING
DESCRIBED PROPERTY.
LOT 1, BLOCK 4, MOUNTAINSIDE VILLAGE SUB.
ANCHORAGE RECORDING DISTRICT, ALASKA AND THAT
THE IMPROVEMENTS SITUATED THEREON ARE WITHIN THE
PROPERTY LINES AND NO VISIBLE ENCROACHMENTS EXIST
OTHER THAN NOTED.
DATED AT ANCHORAGE, ALASKA THIS _28TH_
DAY OF MAY 2002.
HOLT LAND SURVEYING 8600, FB99-55
TEL. 345-5513
5. L GAL DESCRIPTION
DATE RECEIVED
INSPECTION APPOINTMENTS
6. TYPE OF RESIDENCE
TIME
TIME
TIME
DATE
DATE
DATE
iA 1 `) -—
[MSPECTORnn I
CnusI
INSPECTOR
INSPECTOR
® w�
MUNICIPALITY OF ANCHORAGE
* ATTACH WELL LOG. A well log is required for all wells drilled
MUNICIPALITY OF ANCHORAGE DEPT. OF I'" '.CfH ex
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTIRIRONMENU.I. i`i. 'ILCTION
❑ PUBLIC UTILITY
825 L Street- Anchorage, Alaska 99501
•
APPS f 1980
ENVIRONMENTAL SANITATION DIVISION
Telephone 264.4720
INDIVIDUAL WATER AND SEWMA 1'TIP
REQUEST FOR APPROVAL
OF
DIRECTIONS: Complete all parts on page 1. Incomplete requests will riot he processed. Please allow ten 00) clays for processing.
ER
1. P TYOWNE
PHONE
MAI DDRESS
PHONE
PROPERTY RESIDENT If different from shove)
--
2. BUYER
PHONE
MAILING ADDRESS
3. LENDING INSTI UTION ,
PHONE
MAI LING ADDRES§
4. REALTOR/AGENT
PHONE
MAILING ADDRESS
5. L GAL DESCRIPTION
L
STREE OC TION
(1 1!(1 Q3L�1�4c, 1i
nt 'lu
6. TYPE OF RESIDENCE
NUMBER OF,BEDROOMS
ED one El Four EJ Other
INGLE FAMILY
❑ Two ❑ Five
❑ MULTIPLE FAMILY
xr Three ❑ Six_
7. WATER SU PLY
INDIVIDUAL*
* ATTACH WELL LOG. A well log is required for all wells drilled
❑ COMMUNITY
since June 1975. For wells drilled prior to that date, give well
❑ PUBLIC UTILITY
depth (attach log if available.)
S. SEWAGE DISPOSAL SYSTEM
INDIVIDUAL/ON-SITE**
_} l _YEAR ON-SITE SYSTEM WAS INSTALLED.
❑ PUBLIC UTILITY
NOTE: THE INSPECTION FEE MUST ACCOMPANY EACH REQUEST BEFORE PROCESSING CAN BE INITIATED.
72-010 (Rev. 6/79)Y_����/! a�� I✓
THIS SIDE FOR OFFICIAL USE ONLY
1. TYPE OF RESIDENCE
❑ SINGLE FAMILY
❑ MULTIPLE FAMILY
NUMBER OF BEDROOMS
❑ ONE ❑ THREE ❑ FIVE ❑ OTHER
❑ TWO ❑ FOUR ❑ SIX
2. WATER SUPPLY
❑ INDIVIDUAL
❑ COMMUNITY
❑ PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DEPTH OF WELL
DATE DRILLED
LOG RECEIVED
3. SEWAGE DISPOSAL SYSTEM
❑INDIVIDUAL/ON -SITE
❑PUBLIC UTILITY
Connection Verified
PERMIT NUMBER
DATE INSTALLED
INSTALLER
❑Septic Tank or ❑ Holding Tank
Size: j SCJ If Tank is homemade
give dimensions:
SOILS RATING
J
TYPE OF TANK
MANUFACTURER
TOTAL ABSORPTION AREA
MATERIAL
4. DISTANCES
WELL T0:
Septic/Holding Tank
Absorption Area
Sewer Line
Nearest Lot Line
Absorption Area to nearest Lot Line
5. COMMENTS
ED"APPROVED FOR BEDROOMS
❑ CONDITIONAL APPROVAL (letter must accompany certificate)
❑ DISAPPROVED
DATE
BY >f�
72-010 (Rev. 6/79)
MUNIC/PAUTY OF ANCHORAGE
0Ey[
EWvKOkw�./
� ,.cTK}N
`
REK[� ENVIRONMENTAL ENGINEERING-
���
/i n«u~,� SRA BOX 1584n 6-D 9/1 )��0
-- ANCHORAGE, ALASKA 99507 '" /`m
(907) 344-1205
]������������
X�&m�����-�8w&�
276"^1361
DAN,IEL R�CERS
SRA BOX �75R
ANCHORA�E AK 995�7
SELL�R SAM!
SUDDIVISION~MT S�DE VILLAI E
BLOCK~�
LOT~1
THE TYPE
SYSTEM IS
A TRENCH
NIT� AN AREA
OF 720 SQ�T,
THE QUANTITY UF �ATE�
ABSO6BE0
DURINC THE
TEST �AS 612
CALLONS,
THE SUILS RATINC EF THE
SYSTEM
AT CONSTRUCTIUN
NAS 175
AND NO�
C[]�OOM^
THE REQJIRED AEA FOR
A 3 BED8OO�
HO]SE
�S 390 SQFT` THIS
HOyE HAS 720 SQFT^
BASED UPON THE TEST DA�A
THE "q.'.'::.
IS
ACCEPTABLE FO� A
3 BED8OOM HOME
�
'
1 ' i�^v C/Ro�,
N^�/��5|�/'��`.�,�
;
j.0.
Municipafity
f
Anc av e
825 "L." STREET
ANCHORAGE, ALASKA 99501
(907) 264-4111
GEORGF M. SULLIVAN,
NIA"
DEPARINILeN I" OF IILALTH AND ENVIRONMENTAL PPOTECT'ION
April 18, 1980
Dan Rogers
Star Route A Box 475-R
Anchorage, Alaska 99507
Subject: Lot 1. Block 4 Mountainside Village
(TllN R31q Section 11 NE;)
Approval for your individual sewer and water facilities
can not be granted until the following items have been
completed:
(1.) A well log submitted to this department for our
review.I x �. G �J / &� Cz .
1 The water analysis report be delivered to this
office from Chem Lab, 5633 B Street, for our
review.
(3) The septic tank pumped with a receipt submitted to
this office.
(4) An adequacy test be performed on the existing leaching
area. This test will determine if the system is
adequate according to National Standards. A listing
of private farms performing the test is enclosed. This
report needs to be submitted to this department for our
review.
If there are any further questions, please contact this
office at 264-4720.
Sincerely,
Robert C. Pratt, R.S.
Associate Specialist
RCP/1. j w
cc: Alaska Pacific Bank
101 Benson Boulevard 99503