HomeMy WebLinkAboutVALLI VUE ESTATES #2 BLK 3 LT 45Valli Vu Block Lot 45 #015- $22-18 MunMpalh~ of Anchorage: Development Services Department Budding Safely Division On-S;te Water and Wastewater Program, 4700 $. Page I P.O. Box 196650 ~nchorage. A~ 99519-6650 of"~ www.d.anchernge.a[us (907) ~4~-7504 ON-SITE WASTEWATER DISPOSAL SYSTEM ANDIOR WELl. INSPECTION REPORT I1~ Z4z~r~O~ q?~l[- ~ ~ ABSORPTION FIELD w.~,. SEPARATION DISTANCES ~s~ O m~,, D s.~.~m. ~ ot~ Tank Field $ta~on Tank Lo{ t,J¢4 S & S ENGINEERING ,ns-ec'i ~ .- 170~4EaglaRIvarLoopRead, N~ ~ 1" p ~ ons penormea oy: Eagle RI,,,, Alaska ~$~ uates. 2 Deve~opmen~ ~e~ices De~men~ A~prowl ~v,i~,~/ed and approved by: ~ Date: I~/~/~ PERMIT NO. SW020362 PACE 2 o~' 3 Municipg!,J~y oF .A?c:h.o..r'gg.e, DEPARTHENT OF 'HEALTHANI.) HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION · P,a. Box 196650 e..A~chop~ge, A.~l~sk(l 99519-665.0e Te.l.e, pho,~e:. 343-4744 ON-SITE WASTEWATER DISPOSAL :SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 45, BLOCK 3, VALLI VUE ESTATES #2 P.I,D. NO. 015-322-18 LOT 44 SUMp~SUMP TN~, MT1 .'.' DBL2 NEW 1000 GALLON HOPE SEPTIC TANK LOT ,5 LOT 4 PERMIT NO. SW020562 PAGE 5 OF 5 MuniciDotit:.._TY_gP DEPARTHENT OF HEALTHAND HUMAN SERVICES ENVIRONHENTAL SERVICES DIVISION P.D. Box 196650 eAncho,"o, ge, Ato. sko, 99519-6650 · Teleohone: 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 45, BLOCK 5, VALLI VUE ESTATES #2 P.I.D. NO. 015-322-18 ST1 ST_~- 99.7' FINAL GRADE-/ ~-2" INSULATION / 94,5'~4.2' SEPTIC TANK FINAL GRADE/ IV[T1 =87.7' ~ MT2=8'7.5' CO1 =99.4' C'~_.. CO1 =93.7' C02=93.5' · NO WATER FOUND 81.0' B.O.H. A B C ST1 14.O' 17.5' - ST2 12.O' 20.0' - TMT 15.0' 21.5' - DBL1 10.5' 28.0' - DBL2 10.5' 28.5' - CO1 22.5' - 20.0' MT1 25.0' - 22.5' CO2 40.5' 44.5' - MT2 59.5' 45.0' - MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Upgrade Date Issued: Sep 18, 2002 Expiration Date: Sep 18, 2003 Permit Number: SW020362 Legal Description: VALLI VUE ESTATES #2 BLK 3 LT 45 Design Engineer: 0003 S & S Engineering Owner Name: Joseph Julian Owner Addrass: PO BOX 113283 Total Bedrooms: 3 ANCHORAGE, AK 99511-3283 Parcel ID: 015-322-18 Site Address: 010511 LONE TREE DR Lot Size: 20488 SQ. FT. Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each Inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~-,,'~2 ~ Municipality ot' Anchorage DeOelopment Set, ices Department Building Safely Division On-Slie Water end Waslewater Program 4700 South Bragaw SI. P.O. Box '196650 Anchorage, Al< 995t9-6650 www.cl.enchorage.ak.us (907) 343-7904 ParcelI.D. ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING 0 / ~'- ."."~'Z.~." /~ Permit Number SWO20~Z. Property owner(s) Mailing address (t) Mailing address (2) Legal description (Lot. Block & Sub'd.) Legal description (Section. ToWnshlp & Range) Lo s ze ?.ot Day phone ?HIs A~,PLIcA'rloN Is FoR: Sewer Only Sewer and Well Sewer Upgrade .tHis PROPERTY CONTAINs: Ho{ Tub Swlmmlng Pool 'therapy Pool Zip Code Humber of Bedrooms Well Only Water Storage Jacuzzi Water Softenlng Unit [] I ceH, l[y that the above Information Is correcL I fur[her ced(fy that thls application Is being made for a Slngle Famlly DWellln§ and Is In accordance with applicable Idunlctpal Codes. '~2 ,~ ,- S & $ ENGINEERING (Slgnalure of property owner or authorized agent) 17034 Eagle River L~op Road, Ne. 2~l Eagle River, Ala~,ka 99577 i~ermtl Fees: Date of Payment: Receipt Humber: (Rev. Walver Fees: Dale o{' Payment: Receipt Humber: September 12, 2002 MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 45, Block 3, Valli Vue Estates Subdivision//2 ROBERT C. COWAN, P.E. CIVH. ENGINEERS (9O7) 694-2979 FAX (907) 694-1211 It is requested that you issue a permit to upgrade a septic system to serve the existing three bedroom dwelling on the referenced property. A waiver of 15 feet is also requested between the existing trench & the proposed trench. One test hole was excavated and a percolation test was performed on 8/30/02. The approximate location ofthe test hole is located on the attached site plan. Ground water was monitored and after seven days the test hole was dry as shown on the attached soils logs. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any ofthe adjacent properties. If you require additional information, please contact us. Sincerely, Robert C. Cowan, P.E. RCC/jhm Enclosure 17034 NORTH EAGLE RNER LOOP · SUITE 204 ', EAGLE RNER. N.A~KA 99511' LOT 45, BLOCK J.H.M. DESIGN CRITERIA: a BDRM -- 450 OPD SOILS ~ 0.6 GPD/SQ.~'T. 450/0.6 = ?50 Sq,FT. Rgq'D. TRENCH CRITERIA: 13' DEEP 6' EFFECTIVE 3' WIDE 63' LONG Z ALL PORTIONS OF SYSTEM WITH LESS THAN ,5.5' OF COVER REQUIRE INSIJL~TION. ~, VALLI VUE ESTATES S/D R,C,C. 9-12-02 I OF FRED WALATKA 44 5 EXISTING TRENCH (TO BE RETAINED FOR FUTURE USE) CONTRACTOR IS REQUIRED TO Oi~TAIN U~MTY LOCATES PRIOR TO ANY EXCAVAT{ON WORK.  '~ PROPOSED ~-xu~'/TR£NcH , ~?s~ INSTALL ! 2 DIV£RT£R ~. VALVE ~ DOUBLE ~ CLEANOUT~ PROPO~[O ' I000 GALLON ~ ~ HOPE SEPTIC ~ TANK ~ EXISTING / CRUSHED & / .......... J.H.M J R.C.C. DESIGN CRITERIA: 3 eDRM = 4S0 GPD SOILS = 0.6 GPD/SQ.FT. ' 4~o/o.6 = 750 sq.rr. REq'D. / / TRENCH CRITERIA: 13' DEEP 6' EFFECTIVE 3' WIDE LOT 45, BLOCK 3, VALLI VUE ESTATES S/D 9-12-02 2 OF 2 EXISTING TRENCH (TO BE RETAINED FOR FUTURE USE) (9o7)694-2919 63' LONG II ~ PROPOSED "" ~-'~ ~.~...38' ~L--~-'"'"~I 4~ /RE - -DC ~ ~~~ CL 1000 HDPE TANK TRENCH INSTALL DIVERTER VALVE I DOUBLE CLEANOUT PROPOSED GALLON SEPTIC STR~CTURES. EASEMENTS, OR ENCROACHMENTS SIlO ~N ON THIS SITE PLAN ARE AS SHOWN ON AN aS-BUiLT SURVEY DRAWN BY: FRED WALATKA IT [.~ THE RL~PONSIBILTY OF THE CONTRACTOR TO ~ER{FY E,~SEMENTS. REQU{RED SEPARATION DISTANCES. AND PROPERTY UNES PRIOR TO CONSTRUCTIOI. CONTRACTOR IS REQUIRED TO OBTAIN UTILITY LOCATES PRIOR TO ANY EXCAVATION SEPTIC TANK J woRK. (TO BE PUMPED, / CRUSHED & I ALL PO,,,ONS oF sYsT[~ ~ EXISTING ABANDONFn~ I/ ,, WITH LESS THAN 5.5' OF / COVER "£QUlR[ INSULATION. ~ WAT E R LIN E Municipality of Anchorage Development Services Departmenl B ~ld'mg Safety ~ OmS[le Water ~ Wastew~ter Pro, ram 4700 South Bragaw SL P.O. Box 196650 Agcho~ge, AK 99519-.~650 wve, v Soils Log - Percolation Test Performed For:. ~' 0 ~- LegalDescripUon: LO7' H*.,~" J~L~" .~' V,~r4.1 ~/~,/f... EI;r~rT~ownshlp. Range, sact:e~: Slo~e ~t) 1- 4. 5- 7- 8- 9- 10- 20- G ~' O ~G,4,v~ C j' WAS GROUND WATER IF YES, AT ~T DEP~ &1onItorlng? Date: ~/~/, ~ Reading Date $ L 0 P E Gross Time Net Time Depth to Water Net Drop 3 0 30 ~,,,, ~" "~ ." 30 - ~ %" - G 0 20 ,~,,,, '*7 ~1,~"3. * ~ 0 30 ~.,~ ~" ~." COMMENTS PERCOLATIONRAT_= ~ ~" p~k~,ec,~) PERCHOLEDIAt4ETER . ~ ,~/ TEST RLRq BE'P/VEC. N --J '/~ FT ANO~I/;~.FT ON-SITE WASTE~VATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and · MATERIAL SPECIFICATIONS REFERENCE: Lot 45, Block 3, Valli Vue Subdivision//2 September 12, 2002 GENERAL: ROBERT C. COWAN, P.E. CML ENGINEERS (9o7) e94-2979 FAX (907) 694-1211 The scope of this project includes the installation of a 1000 gallon Premier polyethylene septic tank and a new trench to serve the existing three bedroom residence located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property mvner shall be responsible for final grading areas subsequently depressed from soil settling. Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval frt/m the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 7034 NORTH EAGLE RIVER LOOP · SUffE 204 · EAGLE RIVER. ALASKA 99577 Page 2 Lot 45, Block 3, Valll Vue $/D #2 September t 2, 2002 All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Septic tanks installed with less than 4 ft. ofcover shall be insulated. A foundation cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ~. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCll/DRAINFIELD ]INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom ofthe excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (rafted-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert ofthe distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page 3 Lot 45~ Block 3, Valll Vue B/D #2 September 12, 2002 MINIMUM MATERIAL SPECIFICATIONS: !. Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Cast Iron ASTM D3034 (PVC) ASTM FSI0 (HDPE) ASTM D2662 (ABS) Perforated Solid Yes Yes Yes Yes Yes No Yes Yes Use of a type ofpipe other than listed above must be approved by the inspecting engineer. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the//200 sieve. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: Page 4 Lot 45, Block 3, VaUl Vue B/D #2 September 12, 2002 The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading ofthe property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre- construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR / INSTALLER GREJ, ANCHORAGE AREA Department of Environmental Quality 3330 C Street Anchorage, Alaska 99503 INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM NAME ~) ~'0¢¢'~ LOCATION SEPTIC TANK: DISTANCE , NUMBER OF FROM WELL bO" ~ MANUFACTURER ~4~¢,¢'- MATERIAL 1~'¢,¢~f COMPARTMENTS ~ LIQUID DEPTH ~ LIQUID CAPACITY /~)~10 GALLONS. INSIDE LENGTH INSIDE WIDTH DISTANCE FROM WELL '~:~)'~FOUNDATION ~"~(~/ NUMBER OF LINES '~-'- DISTANCE BETWEEN LINES ABSORPTION AREA DEPTH: TOP OF TILE TO FINISH GRADE TOTAL LENGTH NEAREST LOT LINE ~'~'~ ! OF LINES ~ TRENCH WIDTH'~ ~ IN. TOTAL EF~FECTIVE SQ. FT. LENGTH OF EACH LINE / ~ [qr / ~ ~2! DEPTH OF FILTER MATERIAL BENEATH TILE [0 ¢ ~q~. ABOVE TILE '~ IN. WELL: TYPE ~/~;~¢4 fi3 Q ~4 ~ CONSTRUCTION __ DEPTH _ BUILDING NEAREST NEAREST SEPTIC SEEPAGE FOUNDATION__ LOT LINE SEWER LINE TANK__ SYSTEM CESSPOOL OTHER SOURCES APPROVED DISAPPROVED REMARKS DISTANCE FROM: DISTANCES: INSTALLED BY: SEWER LINE DEPTH: PIPE MATE RIAL: LOT SLOPE: REMARKS: Form LQ-032 DIAGRAM OF SYSTEM NAME OF APPLICANT ' NSTALLATION LOCATION GREATER ANCHORAGE AREA BOROUGH - 3330 "C" STREET ANCHORAGE. ALASKA 99503 SEWAGE DISPOSAL SYSTEM -- APPLICATION AND PERMIT iNSTALLATION OF: SEPTIC TANK /® TYPE AND SIZE OF FACILITY TO BE SERVED MAILING ADDRESS SEEPAGE PIT DRAIN FIELD OTHER FINANCED THROUGH TO BE INSTALLED BY NOTE~ THIS PERMIT IS NOT VALID WITHOUT SOIL TEST COMPLETION DATE ANTICIPATED FINAL INSPECTION: 24 HOUR NOTICE REQUIRED. BACKFILLING OF ANY SYSTEM WITHOUT FINAL INSPECTION BY THE DEPARTMENT OF ENVIRONMENTAL QUALITY AUTHORITY WILL BE SUBJECT TO PROSECUTION. MINIMUM DISTANCES, REQUIREMENTS SEPTIC TANK SEEPAGE PIT TO NEAREST LOT LINE. WELL TO SEPTIC TANK DRAIN FIELD WATER MAIN TO SEPTIC TANK DRAIN FIELD , DRAIN FIELD SEEPAGE Pit ~ IOe ALSO CONSIDER AREA WELLS. SEEPAGE PIt ~'~ SEPTIC TANK. ~----~/~ t , SEEPAGE PIT TO RIVER, LAKE, STREAM. · DRAIN FIELD CAST IRON INTO AND OUT OF SEPTIC TANK AND INTO CRIB CROSSING GAP Of EXCAVATION 5 FEET iNTO UNDISTURBED SO]L. 4 INCH DIAMETER CAST IRON SIPHON PIPES ON SEPTIC TANK AND SEEPAGE PIT FITTED WITH AIRTIGHT REMOVAI3LE CAPS. GRAVEL BACKFILL ~,,~,~'~ CONFORM TO BOROUGH REGULATIONS DI G INSTAL O . DIAGRAM OF SYSTEM I CERTIFY THAT I AM FAMILIAR WITH THE REQUIREMENTS OF GREATER ANCHORAGE AREA BOROUGH ORDINANCE NO, 28-68 AND THAT THE ABOVE DESCRIBED SYSTEM IS IN ACCORDANCE With SAID CODE,I_ //~ *~///~ Performed For Lenal This "On~ test is ~orth a ~ho~sand Glacier Excavating Date Performed Description: Lot 45 Block 3 ~orm Re~orts Soils Loq YES 5/21/75 Subdivision V~ll~ View Subd. Percolation Test. ~eoth Feet Soil Characteristics Overburden (ML) 2 3-- 4-- 5-- 7__ 10-- Gravelly Silty Sand SM-250 Through out depth of test hole (Occasional cobbles) Was Ground Water Encountered? I~ Yes, At what Depth? Reading Date Gross Time Net Time Depth to H20 Net Drop! Percolation Rate Minute Proposed Installation: Seenaoe Pit Drain Field Deoth of Inlet Depth To Bottom Of Pit Or Trench CnH~ENTS: 250 Squ~re feet drainage ~re~ r~q~red p~ h~rnnm NO bedrock or ground water encountered Test Performed By / James D. Mack Data Certified B~:CONSTRUCTION TEST LAB Date: 5./22./7K ~.~~' -~ ~MUNICIPALITY OF ANCHORAGF~ ' ~'~'~.~C ~ DEPARTMENt .' HEALTH AND ENV!RONMENTAL_,'ROTECTION , ~~,~,,¢ .~....- 825 L Street, ~chorage, Alaska 99501 [L~)]3~~ - ~ 279-2511, ex~. 224, 225 ~ ~,~j~ A..~ ~' Date Received: 'arch 14, 1977 Inspection: Time ;l:~ 2nd Inspection: Time .nspec'o, ~' Inspector- REQUEST ~OR APPR6VAL OF INDIVIDUAL SEWER AND WATER FACILITIES Lending Institution Request: First National Bank of Anchorage Mailing Address: Post Office Box 4-20'90 Phone: 274-1521 2. Property Owner: John/Muriel Henry Phone: 789-28'83 Mailing Address; Post Office Box 744 Douglas, Alaska 99824 Contact: Mike Messick, Dynamic Realty 279-~611 3. Legal Description: Lot 45 Block,~'Valli Vue Estates ~2 10511 Lone Tree Drive 4. Single Family Residence: (X) Number of Bedrooms: ? Multiple Family Residence: ( ) Number of Bedrooms: Well Data: Type Community Depth Well Log Filed ( ) Construction Bacterial Analysis Sewage Disposal System: On-site system Ix) Public Utility () Permit a Installed Installer Septic Tank Size Manufacturer Absorption Area Soils Rate Material Distances: Well ~o Septic Tank to Sewer Lines Nearest Lot Absorption Area ~o Nearest Lot Line Line to Absorption Area ~age ~wo Department of k~quest for Approval Health and Environmental Protection of Individual Sewer and Water Facilities Legal Description: Lot 45 Block 2 Valli Vue Estates ~2 Comments: Affadavit Attached: ( ) Letter Attached: ( ) Disapproved: Date: Date: Department Worksheet: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION 2510 East Tudor Road, Anchorage, Alaska 99504 276-2221 REQUEST FOR APPROVAL OF INDIVIDUAL SEWER and WATER FACILITIES 1. Type of Inspection: CMRO VA FHA 2. Property Owner: John and Muriel Henry Mailing Address: P;O. Box 744 Douglas Ak. 99824 Day Phone: 3. Name of Buyer: Joseph C. & Ellyn W. Julien Jr, Mailing Address: 1922 East Logan Day Phone: 4. Name of Lending Institution: First National Bank of Anchorage Mailing Address: P.O. Box 4-2090 99509 Phone: 5. Name of Realtor or Agent: MiMe Messick Dynamic Realty CONY XXXX 789-2883 272-4541 274-1521 Mailing Address: Legal Description: Location: 501 West Northern Lights Phone:. 279-7611 Lot 45 Block~Valli Vue Estates #2 10511 Lone TreetDrive 7. Type of Facility to be Inspected: 8. Water Supply Type of Supply: Wales & Septic Public Utility No. Bdrms. ,I ndividual If Individual, number of dwellings presently served If Individual, depth of well Sewage Disposal System Type of System: Public Utility Individual (on-site) XXX If Individual, date of installation MUNICIPAl. IT( OF ANCHOM.G[~ E~IRONtd~FID~L P;~OTECTION i 4 19Y7 RECEIVED MUNICIPALITY OF ANCHORAGE DEPT. OF HEALTH & ENVIRONMENfAL PROIFCT[ON I,,iAR i 1977 RECEIVED 72-003(3/76) THE FIRST NATIONAL BANK OF ANCHORAGE March 31, 1977 Mr. John Kennedy Dep't of Health and Environmental Protection Pouch 6-650 Anchorage, AK 99502 MUNICIPALITY OF ANCHORAg~ DEPT. OF HEALTH & I~NVIRONMEN'rAk PROTECTION APR 8 1977 RECEIVED Re: Lot 45, Block 3, Valli Vue Estates Subdivision No. 2 Dear Mr. Kennedy: We are in receipt of your letter, dated March 18, 1977, informing us of the necessary work to be performed before you can issue your approval of the sewage disposal system. We are holding in our escrow account $750.00 until such time as the necessary work can be performed. Please issue your temporary approval on this bases. A copy of our Cashier's Check is attached for your file. Please let us hear from you soon. Very truly yours, Marianne Nolan Assistant Cashier/Closer Enclosure SOUTH CENTER BRANCH · 201 WEST 36th AVENUE · P.O. BOX4-2090 · ANCHORAGE, ALASKA 99509 1977 First National Bank of A~chorage Post Office Box 4-2090 ~%chorage, Alaska 99509 8ubJeot~ Lot 45 Block 2 Valli Vuo g~tate~ Subaivision 92 This d~par~men~'s inspe~tio~ r~port of the existing sewage disposal system indicates that at the ~ime of installation, there wer~ t~o (2} Sumps, on~ at ~ach end of ~e trench and '~wo (~) cleanouts at th~ During an insp~etion e~ January 3, 1977, on~y one of tho sumps mentioned above wa~ visible. Bufore thi~ department can grant final a~)proval of you3f request the other s~p T~mporary approval, however', will b~ granted if funds are weather permit~. If ther~ are any f~rther qu~s~ions, piuas~ contact this office at 279-2511, ext~nslon ~24 or 225. Sin~er~ly~ John Kennedy Principal ~vironmen~al Control Officer JK/ljh John/F~uriel ~nry ~_~.!05'FI [_one Tre_e_Drfve Anchorage · - .... Co.n,y s,.,. A~ _Le~lO~escrio,ion 'Lot 45~ Block 3 'Valli Vue Estates Subdivision Henry Aopraiser Johnson/Ferrara InstruclronstoApora,sel L~x~Ji~n [~] U,ba~ L~subu,ban Built Up .':] ~]Over 75%' [~25% lo 75% L~Under 25% Growtl~ Rale [] Fully Dev.' []Rapid . [~Steady []Slow Employment S,abiNl¥ [] [~ [] Conven,ence IO Empio;menl [] [] [] [] ~e:reat~o.m Facilitme, .' 0 ~ 0 0 Prot~t;onfromDetrimentaiCondltlons O ~ 0 0~00 Single Family ~e ~ '?~c:J %' 0 y~s tO ' .K. 3 yr$ P~edom;nant A~ 2 ws ~p~)eal to Market 0 v~bw~ ]e~q~oqn cables; co~un~ty water w~th s~te septic. Considered one nf'~hP finP~_ laP~ lot~uh~divJsions inthe "~dm" ar~ nf An~ ~..' ' ' ~ a~cess,to the area'.is via O'Malley Road which Js ~a~ed~a~9~ac~t~C~eareM~'ng built'~in this oesirable subdivision ...... ~ . Oin~e~io~s irreqular< .... ~- :>:-:;:;~ = 20',4~-8 . Sq. F,. ~,X~Y~ ' , ' E] Co,~Lo, - ' '"t. ........... I' TE PROVEMENTS TOpo typ]~ -.... -. w~,.c~:'~ "' ' '...s~.. ..... ..... Js.,f~.~:._.:qravel .Js~p. standard . :..~' ..... ,;?--?~ . - ., ~ , standard · . .-,. Ibis,is a t~Tca],.s]ze and quality Va]Il Vue Ex}sting (app,ox. yr. bH.] 19'75J~o.u.;,, I Tv~ ,J O.,~.o,.d Ou.d.,co.,',V.:,~o. INo. S.o.o, 1: detachedj '. ,' spl it entry R~fMaterial ;:]~t.~ Gu,,e,~&Oownspouls ~Non~WinaowiTy~}: 'casement/ built up .J~ adequate 'oh [ -, . ' ~ ~StormSash ~Sc~een~ L-:Combi~ation ~:oun~lion Wall~ '~";" ' ~ ] 00 % Basement ~ Floor Drain F;mished Ceil;rig ,'conc. block '.~:?L-'~o0~,~.~.,,.... gs~...~ ~c,.~m sm:~ .. F,~.'i .... ~ ~,~ru aarage m.~,h.d W~., sheetrock ~co ,~,~,. ~oor 1 AR ~ Fi.i,~,d F,.~.... ~oo, car~et/vinyl ~SlabonGrade . '"']]~:~'~;~" ~ ~videnceof: ~Oampnes~ ~Te,mhe, ~Setdemen~ ' c.~. B~ment:has been finsihed off since.o~rers E~ possession. cedar F[o~ :. L]Hardwood 4: ~Y~]Carpe! Over Floor OCeram;c ~t:..:.;~ ~yinyl '",, -' $~alFealura~ Iincludi~gfireplac~}: fireplace of used 6ric~ '~ en~, c~t~lo~t doors, :;~iihed (Oe~ri~) , 0 Healed lo. Ca?.~J~Adequale [~ In.'dequate Condi'i~n ~lleclive Age ~ ~yfj: "· ' -~ Esl. Rema~mng EconomicLife69 y,,. O~CNES. PaT OS. POOL. FENC~S..,c. (d.,c,iN) ] 5.5~eck; 4 X 40~.covered wa] kway. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater. Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. 015-322-18 Expiration Date: GENERAL INFORMATION Complete legal description Valli Vue Estates Subdivision No. 2, Block 3, Lot 45 Location (site address) 10511 Lone Tree Drive Anchorage, AK 99516 Current Property owner(s) Joseph and Ellyn Julien Mailing address P.O. Box 113283 Anchorage, AK 99511 Lending agency Day phone Mailing address Day phone Real;Estate Agent "Mailing Add'~ess UnloSs otl~erwise r°~questocl, COSA w#l be held by DSD ~or pickup. 2. NUMBER'OF BEDROOMS: Three(3) DaY phone TYPE OF WATER SUPPLY: ,IndividUal WelJ [] Individual Water Storage [] Community Class ~ Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and maY be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O, Box 240773 Anchorage, AK 99524 Engineer's Pdnted Name Michael E. Anderson, P.E. DSD SIGNATURE ~ Approved for .~ Disapproved. Conditional approval for bedrooms. Phone 522-7773 Date 8/2/2011 bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory (Rev. 11/05) X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other' Original Certificate Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 9951g-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: A. WELL DATA Well type C~ass A Date completed Total depth ~ Lot 45, Block 3, Valli Vue Estates No. 2 Parcel ID: 015-322-18 IfA, B, or C provide PWSID #210605 Sanitary seal' (Y/N) Cased to ft. FROM WELL LOG Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies/100 mL Arsenic: mg/I B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Plastic Tank size 1,000 gal. Foundation cleanout (Y/N) Y Date of pumping 9/8/2010 C. ABSORPTION FIELD DATA Date installed 9/27/02 Length 63 ft. Total depth 13- 15 ft. Well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION in. g.p.m, g.p.m. Nitrate ~ mg/L Other bacteda ~ Date of sample: Collected by: colonies/100 mL Date installed 9/27/02 Number of Compartments Two Cleanouts (Y/N) Depression over tank (Y/N) N High water alarm (Y/N) Pumper 'McDonald's pUmping Service Y N Soil rating (g.p.d./ft2 or ~/bdrm).6 GPD/SF Width 4 ft. Eft. absorption area 756 ft2 Monitoring tube System type Deep Trench Gravel below pipe 6 Y Depression over field N Date of adequacy test 7/27/2011 Results (Pass/Fail) Pass For 3 bedrooms Fluid depth in absorption field before test 36 in. Water added 500 gal. New depth 42 Elapsed Time: 1,440 min. Final fluid depth 36 in. Absorption rate >= 450 Any rejuvenation treatment (past 12 mo.) (YIN & type) If yes, give date in. g.p.d. UFT STATION Date installed. "Pump on" level at Datum in. E. SEPARATION DISTANCES Size in gallons "Pump off" level at Cycles tested SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Animal containment areas in. Property line lO' Water Service line >1~o' Curtain drain None Noted F. COMMENTS: Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? in. On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5. Property line >5. Water main N/A water service line >1o' Walls on adjacent lots >2oo' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation >1o' Surface water >1oo' walls on adjacent lots >2oo' Absorption field. >5' Surface water >1oo' Water main >10' Driveway, parking/vehicle storage. >25' G ENGINEER'S CERTIFICATION . _ I certify that I have determined through field inspections ano review of Municipal records ,that the above systems are in con rmance, cosA gui ine in on thi date. COSA Fee $ /'{ ? 0 Date of Payment C_~/~ ! Receipt Number ~) C~ ~.. ~'7 ~ (Rev. 11105) Waiver Fee $ Date of Payment Receipt Number