ON -SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP241127 PID Number:01 5-192-04
Dwelling: E Single Family (SF) El with ADU R Duplex (D) F-1 Two Single Family Project: El New E Upgrade
Name
DOUGLAS P SIMON
ABSORPTION FIELD - ADVANTEX W1 FAP 2.0
El Deep Trench n Wide Trench E Bed E Mound
Site Address
11441 BROWDER AVENUE, ANCHORAGE
0 Other
Phone
Number of Bedrooms
Soil Rating
Total depth from original grade
1 3
2 GPD/SFI
0.5 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
0 Ft,
Gravel depth beneath pipe
0.5 Ft.
Subdivision Block Lot
TRAILS END 7 2
VARIES 2.49'— 2.55 Ft.
Gravel length
15 Ft.
Township Range Section
Gravel width
15 Ft.
Beds: Number of Lines
3
Distance between lines
5 Ft.
SEPARATION DISTANCES
To, Septic Absorption Holding 1 Sewer
Lift Station ; I
Total absorption area
Number of trenches
Dist. between trenches
From Tank Field Tank 1 Line
225 Ft2
NA
NA Ft.
Well 50'+ 50'+ 50'+ 25'+
TANK El Septic El S.T.E.P. El Holding
0 Other ADVANTEX
Manufacturer
ORENCO ANCH. TANK
Capacity
1500 Gal.
Surface Water 50'+ 50'+ 50'+
Material
COMPOSITE PLASTIC
Number of compartments
2
Lot Line +
5'+ 5'+ 5' NA
Foundation 10'+ 10'+ 10'+
LIFT STATION - PUMP BASIN
Manufacturer
ORENCO
Capacity
75+ Gal.
Remarks DECOMMISSIONED OLD SEPTIC SYSTEM & INSTALLED
NEW AX FAP2 W/ PUMP BASIN & FIELD, BED INSULATED.
Alarm location
Electrical installed by
FIRST FLOOR
DRS
Installer JRS
PIPE MATERIAL House to tank 3034 drainfield Tank to 3034
Drainfield 3034 CO/MT 3034
Inspector FWC
BENCH MARK (Assumed elevation) 100 ft
Inspection 16t 6/24/2024
.
Location and description
3rd 6/26/24 4 1h 6/27/24
FOP OF MANHOLE MH)
ON -SITE WATER AND WASTEWATER SECTION APPROVAL
Conditional Approval: Date
A
t
F 1H
" 9 i
....4.... . .........
Septic System
Aroved -
Curtis Huffman
Date
CE128991
6/27/24
.
S X�
OPROFESSO,-0-
Note: this approval does not include well permit requirements.
kmtev VDIUZ/ jo)
PID:015-192-04PERMIT:OSP241127
FIRST WATER CONSULTING
TRAILS END BLOCK 7, LOT 2
3030 Sues Way - Anchorage, Alaska 99516
Tel. 907-350-9566 firstwaterAK@gmail.com
SOILS LOG - PERCOLATION TEST
LEGAL : TRAILS END B7, L2
PERFORMED BY: FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT
ON THIS DATE. DATE: 6/14/24
DEPTH
FEET
OG
SOILS
1
2
ORG/OL
3
4
5
6
GM/sm/ml
7
8
BOH
9
10
11
12
13
14
15
16
17
18
19
20
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
PERCOLATION RATE NA (MIN / INCH)
TEST RUN BEWTWEEN NA & NA FT
PERC HOLE DIAMETER 6”
PRE-SOAKED PRIOR TO TEST & ALL READINGS TO
THE 1/16TH.
GROUND WATER ENCOUNTERED: YES
IF YES, AT WHAT DEPTH: 4’
DEPTH TO WATER AT MONITORING: 4.5’
DATE: 6/14/24
TESTHOLE # 24-2 DATE PERFORMED: 6/7/24
SEE SITE PLAN FOR SLOPE & LOCATION
COMMENTS:
GROUNDWATER MONITORING ONLY – SIMILAR
SILTY SOILS PER ORIGINAL TESTHOLE.
ADVANTEX BED WILL BE 3.5’+ ABOVE
GROUNDWATER LEVEL MONITORED IN JUNE.
PERFORMED FOR: DOUG SIMON
6/14/24
1
LOT 1
BLK 7
1 30'
N89"59'30"E 190.00
If
7 V
GRAVEL
PARKING
LLJ
CD (D
0 0
0
0
w LOT 2
>
< BLK 7 SHED
r LLB
Ld L) CK
ctr_ 3' X 15' 16,32 0
(,ij CD CANT (D
0
0 .0, 2al-v
0 WELL co 301, 5'— (D
0 0 6_3
5 1�0 cc �SHED 1
CJ
ry (D PAVED 0
it MHO
M D/W a o EX/STING •�) 0
HOUSE M H VAULT
SEPTIC 0
36. PIPE
DECk-
(typ)
1w
_00
Cv X
C14
83.0*
N89*59'30"E 190.00' 4
K,
LOT 3
BLK 7
ANCHORAGE RECORDING DISTRICT, ALASKA
AS -BUILT OF:
TRAILS END SUBDIVISION 00 FND 5/8" REBAR
LOT 2 BLOCK 7 PLAT P-604 'W
&X NN SUP
SURVEY CERTIFICATE: 1, John L. Schuller, Have conducted a lopw��'. O.FN. L ANr
AW
physical survey of this property as shown on this drawing and that the 0
'� �~lop
improvements situated hereon are within the property lines and no
00,
enchroachments exist other than noted. Under no circumstance should , C'� 49TH
0�, �, r
any information on this drawing be used for construction of fences, ..... .......... .......
structures, improvements, or for establishing boundary lines.?A ,� / tit
..............
EXCLUSION NOTES: It is the owners responsibility, to determine yj ......
JPHN L. SCHULLER.- OR
the existence of any casements, covenants, or restrictions which -.7'11�
'-.
do not appear on the recorded subdivision plat. �; LS-10408
1831 Talkeetna Street
WORK ORDER NUMBER: -DATE: SCAILE. E-MAIL A
JUNE 29, 2024 1 30' schullerokOgmail.com Anchorage, Alaska 99508
DRAWN BY. CHECKED BY; GRID NUMBER: 0 (907) 227-1455 office
24-066 e S S i 0 0 & N"A'alwow
JLS SW2641 240230 (907) 274-4992 fax
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
On -Site Wastewater Disposal System Permit
Permit Number: OSP241127
Work Type: Septic Upgrade
Tax Code Number: 01519204000
Site Legal Address: TRAILS END BILK 7 LT 2 G:2641
Site Mailing Address: 11441 BROWDER AVE, Anchorage
Owner: SIMON DOUGLAS P
Design Engineer: FIRST WATER CONSULTING
This permit is for the construction of:
Effective Date
Expiration Date:
Lot Size in Sq Ft
Total Bedrooms:
6/6/2024
6/6/2025
Q Disposal Field © Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed ori -e day, or
b. Covered, sealed, an'd heated to prevent freezing----
.................
.... �
I Provisions:
• 7 day groundwater monitoring is required prior to construction. Please submit stamped and signed results
with the As -built Inspection Report. If the results require a design change, construction of the system will
stop pending On -Site review and approval.
{deceived -By: ✓�f,�'�i� 'ho giL Date:
Issued By: (/v Date: C;'
ON-SITE SEPTIC/WELL PERMIT APPLICATION
Parcel I.D. 015-192-04
Property owner(s) DOUGLAS P SIMON Day phone
Mailinq address 7955 MESQUITE CIRCLE, ANCHORAGE, AK 99507
Site address 11441 BROWDER AVENUE, ANCHORAGE, AK 99507
Legal description (Sub'd., Block & Lot) TRAILS END BLOCK 7, LOT 2
Legal description (Township, Range & Section)
Lot Size 22,800 Sq. Ft. Number of Bedrooms 3
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(Z all that apply)
Absorption Field
0
Initial D
Single Family (SF)
(w/wo ADU)
Septic Tank
Ifl
Upgrade M
Duplex (D)
D
Holding Tank
D
Renewal El
Multiple Dwellings
D
Privy
❑
(SF and/or D)
Private Well
❑
Water Storage
D
THIS APPLICATION
INCLUDES
A WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable MunicipaC
(Signature of property owner or authorized agent)
Permit/Rush Fees: dggz
Date of Payment:
Receipt Number:
Permit No. 05 P c'2,�i 11 ZZ
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No.
GADevelopment Services\Building Safety\On Site Water and WastewaterTorms\Client Forms\Permit Application.doc
13030 Sues Way, Anchorage, AK 99516
907-350-9566 / firstwaterAK@gmail.com
!
June 6, 2024
Municipalities of Anchorage
On-Site Water & Wastewater Program
4700 Elmore Road
Anchorage, AK 99507
RE: SEPTIC SYSTEM UPGRADE PERMIT
LEGAL: TRAILS END BLOCK 7, LOT 2
The existing septic system has been found failed and will be completely abandoned
or removed as designed and per the owner we request a septic permit to upgrade
the existing septic system on the above referenced lot. We propose to install an
elevated bed-mound with an Advantex FAP 2.0 system with pump basin to serve the
existing 3-bedroom residence per the attached design. This will be a remove &
replace per the proposed design.
The design is based on the 5/18/84 test hole percolation rate of 27.8 minutes per
inch or 239 square feet per bedroom also noted on the MOA Inspection Report
conducted along the edge of the existing bed. Groundwater was observed on 1983
test hole at 8’ per MOA records. An unsatisfactory test hole on the north side of the
property was recently conducted and the soils log is attached. Prior to construction
a test hole will be conducted to verify groundwater per the attached design.
The slopes are moderate at 0-3% at the proposed upgrade location. The lot and
area are served by private water with no known private wells within 50’ of the
proposed septic system. Based on visual observations and review of available
information, the design will not impact any of the neighboring properties. Please
contact us if you have any questions.
Sincerely,
Curtis Huffman, P.E.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241127, Deb Wockenfuss, 06/06/24
FIRST WATER CONSULTING
TRAILS END BLOCK 7, LOT 2
DESIGN CALCS:
NO WELLS WITHIN
100' OF PROPOSED
SEPTIC TANK
NO SLOPES >25% WITHIN 50'
OF PROPOSED FIELD.
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241127, Deb Wockenfuss, 06/06/24
FIRST WATER CONSULTING
DESIGN DETAILS:
TRAILS END BLOCK 7, LOT 2
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241127, Deb Wockenfuss, 06/06/24
13030 Sues Way - Anchorage, Alaska 99516
Tel. 907-350-9566 firstwaterAK@gmail.com
SOILS LOG - PERCOLATION TEST
LEGAL DESCRIPTION: TRAILS END BLOCK 7, LOT 2
PERFORMED BY: FWCS / FWC - I CURTIS HUFFMAN CERTIFY THAT THIS TEST WAS
PERFORMED IN ACCORDANCE WITH ALL STATE & MUNICIPAL GUIDELINES IN EFFECT
ON THIS DATE. DATE: 6/5/24
DEPTH
FEET OG
SOILS
1
ORG/OL-PT
2
3
4
GM-sm/ml
5
6
7
8
9
BOH
10
11
12
13
14
15
16
17
18
19
20
Reading Date Gross
Time
Net
Time
Depth to
Water
Net
Drop
PERCOLATION RATE NA (MIN / INCH)
TEST RUN BEWTWEEN NA & NA FT
PERC HOLE DIAMETER 6”
PRE-SOAKED PRIOR TO TEST & ALL READINGS TO
THE 1/16TH.
GROUND WATER ENCOUNTERED: YES
IF YES, AT WHAT DEPTH: 4’
DEPTH TO WATER AT MONITORING: 2.7’
DATE: 6/5/24
TESTHOLE # 24-1 DATE PERFORMED: 5/29/24
SEE SITE PLAN FOR SLOPE & LOCATION
COMMENTS:
ATTEMPTED PERC, BUT SATURATED SOILS
NO PERC TEST / SOILS RATING
PERFORMED FOR: DOUGLAS P. SIMON
6/5/2024
Municipality of Anchorage
On-site Water and Wastewater
REVIEWED FOR CODE COMPLIANCE
OSP241127, Deb Wockenfuss, 06/06/24
W&UNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTEC ON
ENVIRONMENTAL ENGINEERING DIVISION
825 L Street- Anchorage, Alaska 99501 Telephone 264.4720
ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
NAME
Fele$
.PHONE
176 —/�`
NEW
❑ UPGRADE
MAILING ADDRESS
a/d seW2��l �w
LEGAL DESCRIPTION
L.o4 Z Block 7 Trelith Ehd
LOCATION
ra 1. dai 5)4-ce /.,y
NO. OF BEDROOMS
.3
U Y
DISTANCE TO:
Well //S ��
Absorption area��l
TT
Dwelling /O�
PERMIT OS�
~
Manufacturer Greer
Material SV
No. of compartments z
N
Liq. capacity in gallons
/O O
IF HOMEMADE:
Inside length
Width
Liquid depth
DOz
DISTANCE TO:.
Well
Dwelling
PERMIT NO.
_ F
Manufacturer
Material
Liquid capacity in gallons
w=
DISTANCE TO:
Well
IZ •�
Foundation 1
�Z-F
Nearest lot line p �!
T
PERMIT NO.
LL Z
F Z
No. of lines
Le gthof pch line ,
Total length of lines
Trench width
inches
Distance betwe lines
Q F
T op of tile to finish grade Or
Material beneath the
nches13
Total effective absorption area
q'4
w
f7
Length
Width
Depth
PERMIT NO.
i F
w °
Type of crib
Crib diameter
Crib depth
Total effective absorption area
H
DISTANCE TO:
Well
Building foundation
Nearest lot line
J
J
W
Class
Depth
Driller
Distance to lot line
PERMIT NO.
DISTANCE TO:
Building foundation
Sewer line
Septic tank
Absorption area(s)
OTHER
6
PIPE MATERIALS
P Ve
SOIL TEST RATING
ES
i 11e1 r
r f
3
O
INSTALLER
e
REM RKS
C2C rope of
O
-
()% Aqj!f Wck4 23Ct,F 2 -
APPROVED
APPROVED DATE LEGAL
42
72-015 (Rev. 3//8)
try
1
� 6
k v '.!"'•. T R. F=#L—+11n ■ T
�P` +�1 M1v..L.i� R%a ,�
44..1n
DEPIRRTMENT OF' HEALTH FIND
ENVIRONMENTAL`.PROTMTR N
825 L STREET, ANCHORAGE,,AK 96p6
i
264-4726 _
,�
QP4—:E3
I _r FE :SS:WF=FR
& FSFEF_F_ FI'E'F-ZMi I d7tl '11 '
NG:
i
8'4005
E' SSUED:
03/15104,
`
_ICANT:
FEJES DEVELOPMENT
Ess:
PO BOX 11-2009
ANCHORAGE, AK 99531
rAGT PHONE:
345-5022
iL,DESCRIP:
SECTION: '24 TOWNSHIP:
1.2N RANGE: -
$12E:
22560 (SQ.FT. OR ACRES)
EDRo6MS:
3
E6 BELOW ARE THE OPTIONS AVAILABLE TO YOU IN DESIGNING YOUR SEPT IC
EN CHOOSE THE OPTION THAT BEST FITS YOUR SITE.`
FBF=F
4- TO -PIPE BOTTOM SFT.) 3.5
=1- DEPTHCFT. 7 0.5
;DEPTH <FT.) 4.0
�,L '-WI:DTH . C FT'.) 26.0
# LENGTH (FT. > 51.0
EL • VOLUME'- CCU. YDS.) 49.3 >,
litE CGALSY 1, 0019. 0
RATXNG` {SGA. FT. /BR) 296
EPTH TO PIPE BOTTOM < 4.1 FT. MAY REQUIRE A LIFT STATION
'RrK MUST HAVE AT LEAST TWO COMPARTMENTS
kt IFY - THAT
AM "FAMILIAR WITH THE REQUIREMENTS FOR ON-SITE SEWERS AND' WELLS':
f RTH BY T14E LMUNICIPALITY OF ANCHORAGE (MOj) AND THE STATE.'.OF FIL
,,,WILL INSTALL THE SYSTEM IN ACCORDANCE WITH ALL MOA CODES AND, In,
f}ND'IN,COMPLIANCE WITH THE DESIGN CRITERIA OF THIS: PERMIT:
TWILL ADHERE TO ALL MOA AND STATE OF ALASKA :REQUIREMENTS ;FOR THS-
'
'Vi StANCES'FROM ANY EXISTING WELL, WASTEWATER DISPOSAL SYSTEM ORI'OUi
SEWERAGE SY,STEM'ON THIS OR ANY OR OR -NEARBY LOT.
JNDERSTAND . THAT THIS PERMIT IS VALID FOR A MAXIMUM ,OF 3. BEY)R i( i
19KY.ENLARGEMENT WILL REQUIRE AN ADDITIONAL PERMIT. *..:
LFT 51tA ION:IS INSTALLED IN AN AREA COVERED BY MOA'BUILDING CO
C ).RN ELECTRICAL• PERMIT AND INSPECTION MUST 6E OBTkINED,'C2 ASS
NQT,k APPROVED WITHOUT AN ELECTRICAL INSPECTION REPORT;-, ANDC ) �l
fom WORK MUST BE DONE BY A LICENSED ELECTRICIAN.
Df�tE • � j�'� '�^'r
SANT. FEJES;DEVELOPMEN
tr..
UN PALITY OF ANCHORAGE 1`0 6X_e,_,
Department Hth and Environmenta*501
o0tion
825OStreet, Anchorage, AK.
264-4720
Permit #g&xoaO # # # HANDWRITTEN PERMIT # # #
WELL AND/OR ON-SITE SEWER PERMIT
Applicant:e�_t1�-.Gv ,c,( Mailing Address:t7
Location: Phone Number: y 0/
Legal Description: L a Q") o/4e"Lot Size: 'r
Type of Soil Absorption System Is:
Trench: Drainfield: _ _ Seepage Bed: Holding Tank:
Maximum Number of Bedrooms: -3 Soil Rating(sq.ft/br) -:G 2 f?bJu"%Ib
The Required Size of the Soil Absorption System is:
DEPTH V __ LENGTH-24vyd' _ GRAVEL DEPTH 6 �/ WIDTH
The length dimension is the length(in feet) of the trench or drainfield. The
depth of a trench or pit is the distance between the surface of the ground and
the bottom of the excavation(in feet). There is no set width for trenches.
The gravel depth is the minimum depth of gravel between the outfall pipe and
the bottom of the excavation(in feet).
* * REQUIRED SEPTIC(Fet:B MG) TANK SIZE _ /00 y GALLONS # #
Permit applicant has the responsibility to inform this department during the
installation inspections of any wells adjacent to this property and the number
of residences that the well will serve.
* # * TWO(2) INSPECTIONS ARE REQUIRED * * *
Backfilling of any system without final inspection.and approval by this department
will be subject to prosecution.
Minimum distance between a well and any on-site sewage disposal system is 100 feet
for a private well or 150 to 200 feet from a public well depending upon the type
of public well. Minimum distance from a private well to a private sewer line
is 25 feet and to a community sewer line is 75 feet. Well logs are required
and must be returned to this department within 30 days of the well completion.
Other requirements may apply. Specifications and construction diagrams are
available to insure proper installation.
* * * PERMIT EXPIRES DECEMBER 31, 1 9 3 3 * * *
I certify that:
(1) I am familiar with the requirements for on-site sewers and wells as
set forth by the Municipality of Anchorage.
(2) I will install the system in accordance with codes.
(3) I understand that the on-site sewer system may require enlargement if
the residence is remodeled to include more that 3b)gdrooms.
Signed: Issued by: j
�pplican �'
Date: -7
SWP/024(1/81)
❑ SOILS LOG
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION
TEST
825 L. Street, Anchorage, Alaska 99501 2644720
SOILS LOG — PERCOLATION TEST
PERFORMED FOR: Cnri S F�d`P'S DATE PERFORMED: 5-19—Ptl
LEGAL DESCRIPTION: Lf'
1 SLOPE SITE PLAN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19-
20
-,147, v.vo � so,b a�
le,,io syjA-.n
WAS GROUND WATER
ENCOUNTERED?
flfC-
IF YES, AT WHAT
DEPTH?
'13-w ° k^IA
■■■■■■■■■■
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
■N.
■■■.■■■
1
5-1q-84
1,00
1a
■©.
oas
■■■■M■■
EMISOMMOMME
tl
a
NO
NEINIENE
t■0\�JI■I
3
I
log
EMw
.3
-
„
1.,aI
a
-
Io�
1'
rU
11
1; 33
N
EE
S
1:43
mom
KPI
.vim)
INEENEEMENE
I I
MENEENNIMMOMM
Reading
Date
Gross
Time
Net
Time
Depth to
Water
Net
Drop
1
5-1q-84
1,00
1a
.5-45
oas
—
tl
a
3
I
Itdl
.3
-
„
1.,aI
a
-
Io�
1'
rU
11
1; 33
_
S
1:43
KPI
.vim)
I I
PtH(:ULA I ION HAIL y—/ --/j' lJoN C%04minutes/inch)
TEST RUN BETWEEN 3 A FT AND J-13 FT
PERFORMED BY: (26AA2n ! MC4 tn+ CERTIFIED
72-008 (6/79)
• �• �• IQ SOILS LOG -
/
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION PERCOLATION
TEST
825 L. Street, Anchorage, Alaska 99501 264-4720
SOILS LOG - PERCOLATION TEST
PERFORMED FOR: `-I'I )K J DATE PERFORMED: Y A j lY. !fl-Y.J
DESCRIPTIOPVWIJI
-2
Date
Grass
Time
3
Depth to
Water
C -1M
-^ 4
6 id3
5
69
7
6
7
5.to
„
8�
9
pit-
10 -
t a
11
-
id-
A0 nor)
13
14
15-
51617181920
16-
17-
18-
19-
20
SLOPE
q2�-/z06
�'/) Jo5
WAS GROUND WATER S
ENCOUNTERED? LO
P
E
IF YES, AT WHAT
_Ca1Q01la3 DEPTH?
/.i I W-� �i
COMMENTS CIA
PERFORMED BY: T
72-008 (6/79)
Reading
Date
Grass
Time
Net
Time
Depth to
Water
Net
Drop
`I 5—
6 id3
69
7
,U
176
t a
Ia'-
-
id-
A0 nor)
PERCOLATION RATE (minutes/inch)
TEST RUN BETWEEN L�. J�sFT AND FT
CERTIFIED
M
CP0n0 nTRL C0nTROL SAGS InC.
RLR�KR ,
Engineering & 6nuironmental Studies
SPECIFICATIONS FOR SEEPAGE BED ALTERNATIVE WASTEWATER
TREATMENT SYSTEM— LOT 2, BLOCK 7, TRAILS END SUBDIVISION
1.0 GENERAL
1.1 THE DRAWINGS, SHEETS 1 THRU 2, SHALL BE A PART OF
THIS SPECIFICATION.
1.2 ALL MATERIALS AND WORKMANSHIP SHALL MEET THE
REQUIREMENTS OF ANCHORAGE DEPARTMENT OF HEALTH AND
ENVIRONMENTAL PROTECTION PERMIT.
1.3 IT IS THE RESPONSIBILITY OF THE OWNER TO OBTAIN ALL
NECESSARY PERMITS OR EASEMENTS.
2.0 LIFT STATION (NOT USED).
3.0 SEEPAGE BED
3.1 THE GRAVEL FOR THE BED SHALL BE SIZED BETWEEN 0.5 TO
2.5 INCH AND RELATIVELY FREE FROM SILT OR SAND.
3.2 THE BOTTOM OF THE EXCAVATION SHALL BE RAKED WITH THE
BACKHOE BLADE TO INSURE THAT THE BOTTOM HAS NOT BEEN
COMPACTED DURING EXCAVATION. THE BOTTOM ELEVATION SHALL
BE PLUS OR MINUS 2".
3.3 THE DISTRIBUTION PIPE SHALL BE 4 INCH RIGID PVC OR
POLYETHYLENE. THE PIPES SHALL BE LAID LEVEL.
3.4 AN OBSERVATION PIPE SHALL BE PLACED AS SHOWN IN THE
DRAWINGS. IT SHALL BE RIGID PVC, ASTM 3033 D-3034. THE
SECTION SHOWN WITH HOLES MAY BE EITHER DRILLED 0.5"
HOLES @ 6 INCH CENTERS ON OPPOSITE SIDES OF THE PIPE
OR A REGULAR SECTION OF REGULAR PERFORATED
DISTRIBUTION PIPE MAY BE CLAMPED TO THE SOLID SECTION
WITH A NO HUB COUPLING OR SOLVENT JOINT. A RUBBER RAIN—
CAP (JIMCAP OR EQUAL) SHALL BE PLACED ON THE TOP THE
PIPE.
3.5 THE GRAVEL SHALL BE COVERED WITH A LAYER OF UNTREATED
BUILDING PAPER OR A NONWOVEN FABRIC SUCH AS MIRAFAR
FIBRETEX 200 GRADE, OR POLY—FILTER X OR EQUAL.
3.6 THE INSULATION SHALL BE DOW EXTRUDED BLUE STYROFOAM
BOARD, ARCO GEOFOAM EMBANKMENT INSULATION BOARD OR
WESTERN INSULFOAM II OF THE THICKNESS SHOWN ON THE
DRAWINGS.
3.7 THE TOP OF THE BED SHOULD BE PLANTED WITH A
WHITE CLOVER AND RED FESCUE MIX.
1200 West 33rd Ruenue, Suite B • Anchorage, Alaska 99503 • (907) 276-1361
ALASKA AIMERTAL COnTROL SAUS, InC.
Engineerinq & Enuironmental Studies
June 29, 1984
Department of Health and
Environmental Protection
825 L Street UG
Anchorage, Alaska 99501
Attention: Keith Bandt
Re: Trails End, Block 7, Lot 2
Dear Keith,
Qin 13)3a
P6619 Inc
NOND31oud 1b1N31'VN0
$®Y8NI
®tb dOALnd1 81,>
I visited Lot 2, Block 7, Trails End on June 25, 1984, at approximately
1:00 P.M. The preliminary landscaping has been canpleted and no
depression exist$ over the drainage field. The water test, sampled May
21, 1984 resulted in a satisfactory analysis. I recarmend removal of the
conditional Health Authority. Approval for the Certificate issued May 18,
1984.
REG/caj
e-
'1' 0u
1200 West 33rd Ruenue, Suite 3 9 Anchorage. Alaska 99503 9 (907) 561-5040
ALASKA ENVIRON JOeTa is -thy a{oma 7 L_of 2
CONTROL SERVICE SHEET Ho. 1 OF 2
1200 West 33rd Avenue ui e B M . La n r L -24 - S3
ANCHORAGE, ALASKA 99503 CALCULATED BY DATE
,Phone 276.1361
CHECKED By DATE
OOOOI ml N[. [ M 01471
ALASKA L ERONM
S
CONTROL ERVICf
1200 West 33rd Avenue UMFB
ANCHORAGE, ALASKA 99503
Phone 276.1361
aoe Ir is Gn� dla�k � Lok Z
SHEET NO.{� • -OF `L
-CALCULATED BY M L4VV' DATE
CHECKED BY DATE
MWIICfmLI �� 6+a IK aril.
LOCATION OF WELL
SO
.f'ry
(Please complete either la, Ib or Ic.)
fOATER WELL RECORD
STATE OF ALASKA
DEPARTMENT OF NATURAL RESOURES
Division of Geologicol & Geophysicol Surveys
Drilling Permit No.
;1, A.D.L. No.
to. Borough
ANCH
Subdivision
TRAI(5 ENV
Lott
ph
Block
7
Ib. /4gtra.
_of_of_af_
Section No.
Township N❑
Sp
Range EE]
WE]
Meridian
Ic. DISTANCE AND DIRECTION FROM ROAD INTERSECTIONS
Street Address and Area of Well Location
3. OWNER OF WELL;
Address: CH1215 F£!E$
SRA QOX 9-0
1 t
f1 epi AR 95
2. WELL LOS Feet Below Surfoc
Material Type Top Bottom
B
4. WELL DEPTH: (final)
J 16/7 ft.
5. DATE OF COMPLETION
R
LCA-- — &L — -
- -j-
6. ❑ Cable. tool � Rotary ❑ Driven ❑ Dug
Auger ❑ Jetted ❑ Bored ❑ Other:
/{ YE 6 —
ty❑
e -F AV CIL s ` $t SLAY?®
—
Domestic ❑ Public Supply ❑ Industry
Irrigation C] Recharge ❑commerical
❑ Test Well ❑ Other:
I
I4 V
f `y"❑
A).24f(10.r1
N i^ U l�/
II t� (Z
8. CASING! ❑ Threaded 19 Welded
diam.(_In. tol-4 ft. Depth Weight 17"t Ibs./ft.
diam. _ In. to_ ft. Depth Stickup ft.
"WIV
S. FINISH OF WELL;
Type: Diameter _
Slot/Mesh Size; Length;
Set between ft. and ft.
Backfilling Gravel pack
10. STATIC WATER LEVEL: 4? ft. 1'en
tAT/83
C] Above or ❑ Below land surface . Date
Equipment used: it
I1. PUMPING LEVEL below land surface and YIEL
JW _L52—fl. after _A_hro. pempin9mg•P•m.
ft. after _hra, pumping — 2-P In.
12.6ROUTING. Well Grouted: [] Yea ❑ No
Material; ❑ Neat Cemenfl C] Other:
13. PUMP: (if available) HP
Length of Drop�,Pipe ft. capacity 9 -P.M.
CS ubm. 0 Jet 0 Centrifical ❑ Other
14. REMARKS:
All? LIEF e,flMp(NG
16. WATER WELL CONTRACTORS CERTIFICATION:
15. Water Temperature _o ❑ F ❑ C
This well was drilled under my jurisdiction and this report is true to the best of my knowledge and belief; ..
W N. W H iTE W GU ,U2lLL N46 A- (o-7 goo
Registered Business Name Contract License Number
Address: A
Signed: Date: 27 49c 7- 93
Aufhorizsd Representative s =
Form 02-WWR (11/81) Copy Distribution: WHITE -State OGGS, PINK-Drillert CANARY -Customer
:mm
Certificate of On -Site Systems Approval
Parcel I. D. 015-192-04
Legal description TRAILS END BLK 7 LT 2
Site address 11441 BROWDER AVE Anchorage AK
Current property owner(s) SIMON
Z
Expiration Date: � Z2 Sf
X The On -site system(s) is/are approved for 3 bedrooms
Conditional approval for
Comments or advisories:
M
bedrooms, with the following stipulations:
Original Certificate Date: 7/1 /2024
This Certificate of On -Site Systems Approval (COSA) is intended to demonstrate the subject
system(s) is/are in substantial compliance with municipal code. The Municipality of
Anchorage, Development Services Department (DSD) issues COSAs based upon
representations provided by an independent professional engineer. The Municipality of
Anchorage is not responsible for errors or omissions in the professional engineer's work.
ATTACHMENTS:
COSA Checklist X Well Flow Advisory
Absorption Field Advisory Nitrate Advisory
Tank Age Advisory Arsenic Advisory
Other
COSA Approval June 2022
MUNICIPALITY OF ANCHORAGE
"A
MOM=
4
Development Services Department AQ01, Phone: 907 -343-7904
On -Site Water & Wastewater Section Fax: 907-343-7997
Ef"
Certificate of On -Site Systems Approval Application'
1. GENERAL INFORMATION
Parcel I.D. 015-192-04
Complete legal description TRAILS END BLOCK 7, LOT 2
Location (site address) 11441 BROWDER AVENUE, ANCHORAGE, AK 99516
Current property owner(s) DOUGLAS P SIMON Day phone
2. ON -SITE SYSTEMS SIZED FOR 3 BEDROOMS
3. TYPE OF WATER SUPPLY: Z Private Well 0 Private Well serving 2 dwelling units
El Private Well serving 3+ dwelling units E] Community Well or Public
❑ Water Storage
4. TYPE OF WASTEWATER DISPOSAL: Z Private Septic R Private Septic serving 2 dwelling units
R Holding Tank R Community Septic or Public Sewer
5. SEPTIC TANK: Fj Steel H Plastic R Concrete R Fiberglass
Age NEW - See advisory if steel older than 20 years
6. ABSORPTION FIELD: Z AWWTS E Bed 0 Deep Trench F1 Wide Trench F1 Seepage Pit
Waiver request for:
Expedited review requested: Z
Distance:
By applying for this entitlement, this property is subject to inspection by municipal On -site staff
to verify the accuracy of the information provided.
COSA Fee $ Waiver Fee $
Date of Payment
Date of Payment
COSA # 05C Z_ Waiver #
COSA Application.doc
COSA Checklist NEW.docx
COSA Checklist
Legal Description: TRAILS END BLOCK 7, LOT 2 Parcel ID: 015-192-04
If more than 1 well and/or septic system on lot, provide separate checklist. Structure served by this system ____
A. WELL DATA
Well log is filed with Onsite (or attached)
Date drilled 10/19/1983 Total depth 160 ft
Cased to 159 ft
Sanitary seal is functioning correctly
Wires are properly protected
Casing height (above ground) 12+ in.
Date of flow test for COSA 5/22/2024
Static water level at beginning of test 58 ft.
Well production at time of test 1.8 gpm
Water storage tank volume NONE gallons
Well disinfected for coliform test? Yes No
Coliform bacteria is Negative
Nitrate 2.17 mg/L Nitrate less than MRL (ND)
Arsenic ug/L Arsenic less than MRL (ND)
Collected by Date 5/22/24
Comments
B. TANK DATA
Measured operating fluid level in septic tank NEW
Date of pumping NA – ADVANTEX <1YR
Required maintenance completed, if AWWTS
Comments:
C. LIFT STATION
Required maintenance completed
Age of lift station NEW years
Lift station material PLASTIC
Comments: NEW ADVANTEX SYSTEM
D. ABSORPTION FIELD DATA
Which system tested (date installed) NA - NEW
ALL standpipes present per record drawing
Total measured depth from grade 2.55 ft (max)
Measured depth to pipe invert from grade ft (min)
N/A – pressurized field.
Per record drawings, field is insulated.
Monitor tubes (MT) go to bottom of effective (ED).
If not, state depth into effective
Presoaked required if
(Required if house vacant or field not used for more
than 30 days prior to date of test)
Gallons introduced gallons date
Any rejuvenation treatment (past 12 months) N
If yes, enter date
Adequacy test date NA – NEW FIELD
Results Pass
Fluid depth prior to test in
Water added gal
New fluid depth in
Elapsed time min
Final fluid depth in
Absorption rate gpd
FIELD STATUS – POST RECOVERY – NOT TESTED
Effective depth (per record drawings) 6 in (MOA 0.5’ ED)
Effective depth used 0 in (Missing ED + Final Fluid Depth)
Effective depth (ED) remaining 6 in
Comments/Deficiencies: Approximate total measured depths from existing grade.
COSA Checklist NEW.docx
E. SEPARATION DISTANCES
From Private Well on Lot to: (Please enter distances if less than required or if community well on lot)
Septic Tank/Lift Station on Lot > 100’
Yes if No *50+ ft
Neighboring Tank > 100’ Yes if No ft
Absorption Field on Lot > 100’ Yes if No *50+ ft
Neighboring Absorption Fields > 100’
Yes if No ft
Community Sewer Main > 75’ Yes if No ft
Community Sewer Manhole/Cleanout > 100’
Yes if No ft
Private Sewer/Septic Line > 25’ Yes if No ft
Holding Tank > 100’ Yes if No ft
Animal Containment > 50’ Yes if No ft
Manure/Animal Excreta Storage > 100’
Yes if No ft
N/A – Served by Community Well (not on lot) or Public Water
From Septic/Holding Tank and Absorption Field(s) on Lot to: (Please enter distances if less than required)
Building Foundations > 10’ Yes if No ft
Tank to Property Line > 5’ Yes if No ft
Field to Property Line > 10’ Yes if No *5+ ft
Water Main > 10’ Yes if No ft
Water Service Line > 10’ Yes if No ft
Surface Water > 100’ Yes if No *50+ ft
Wells on Adjacent Lots:
Private Wells > 100’ Yes if No *50+ ft
Community Wells > 200’ Yes if No ft
If tank or field is under driveway comment below
F. ENGINEER’S COMMENTS
*MAY MEET CONVENTIONAL SEPARATIONS, BUT SYSTEM MEETS CATIII SEPARATION DISTANCE REQUIREMENTS.
G. CERTIFICATION & STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based
on procedures outlined in the Certificate of On-Site Systems Approval Guidelines, indicates that the on-site water
supply and/or wastewater disposal system appears to comply with applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation, unless noted otherwise.
Name of Firm FIRST WATER CONSULTING Phone 907-350-9566
Engineer’s Printed Name CURTIS HUFFMAN, PE Date XXXX
Comments: This investigation was completed in compliance with MOA guidelines, regulations,
and best industry practices / methods. The assessment of the condition of the well and septic
applies only to the conditions as of the day tested. The flow and absorption rates may change
due to subsurface conditions that may not be observed from the surface, changes in land use,
local soil characteristics, groundwater levels that may fluctuate during the year, quality of
construction (workmanship & materials), the water usage of the family being served by the
system and maintenance. The operational life of all well and septic systems are subject to
these various and dynamic characteristics and are outside the control of the evaluator of the
well and septic system. Therefore, any or NO estimate of how long a system will function satisfactory
for current or future occupants or guarantee that no unseen encroachments, deficiencies or
discrepancies exist can be given by First Water Consulting &
XXXX
DocuSign Envelope ID: 4A9DB65A-C781-48D3-885B-4E521484FC50
MUNICIPALITY OF ANCHORAGE
ADVANCED WASTEWATER TREATMENT SYSTEM
MAINTENANCE AND REPAIR AGREEMENT
THIS MAINTENANCE AND REPAIR AGREEMENT, herein the "AGREEMENT" made and
entered into as of this Day of '-3—,k l -L of 20q, by and between
-a OC.�iFf t-V , herein the "OWNER," and the Municipality of
Anchorage, herein the "MUNICIPALITY", in accordance with Anchorage Municipal Code
(AMC) 15.65.365. In consideration of the mutual covenants contained herein, the parties to this
Agreement agree as follows:
1. Advanced 'Wastewater Treatment Systems. The Municipality grants permission to the
Owner to utilize and operate an Advanced Wastewater Treatment System (AWWTS),
described as AN ADVANTEX SYSTEM
located at (legal description)
TRAILS END BLOCK 7, LOT 2
2. Maintenance, Repairs and Alterations.
(Owner is required to read, understand and initial each section)
Throughout the term of this Agreement, the Owner shall enter into a service agreement
with an AWWTS service and maintenance provider approved by the Municipality or the
manufacturer's representative. The AWWTS shall be maintained in a satisfactory
condition capable of performing as designed and producing treated septic effluent in
accordance with the equipment's approval for operation in the Municipality.
It shall be the responsibility of the Owner during the term of this Agreement to pay for all
repair(s), maintenance, adjustment(s), replacement costs, and inspection costs. This
includes an annual maintenance fee (typically $400 to $600).
Q
X Owner agrees that only maintenance and repair personnel approved by the Municipality
or the manufacturer's representative will inspect and make any necessary maintenance,
repairs or permitted alterations to the system.
'�),,�4—"Owner acknowledges that regular maintenance of an AWWTS reduces the potential
failure of the system, which could include sewage backup and costly repairs or drainfield
replacement.
(rev. 05/18/2018) Page 1 of 3
DocuSign Envelope ID: 4A9DB65A-C781-48D3-885B-4E521484FC50
Owner acknowledges that the Municipality may request records of maintenance and
repairs from the manufacturer's representative or maintenance provider.
Owner acknowledges that the fine for failing to maintain and repair an AWWTS may be
assessed in accordance with AMC 14.60.030.
Owner agrees to grant the Municipality reasonable access to test and inspect the
AWWTS. The Municipality will give at least 24-hour notice.
;' Owner agrees that any sale or transfer of title of the property will not occur without a new
Certificate of On -Site Systems Approval.
Owner agrees that the AWWTS installation and maintenance requirements as provided
r--•-rb the�,�„.}+, WTS, uendor4astaller and approved by the Municipality are the governing
uictPit�'fo,klieinucton, maintenance and repair of the Owner's AWWTS.
ii -1
()wr a ,a�r�ggsAoSftointain r1mote monitoring of the AWWTS as required by the
3. Term. The term of this Agreement shall begin on the date of approval by the
Municipality to operate the installed system, or upon transfer of title, and shall continue
while the AWWTS is operational or until title is transferred.
4. Nonwaiver. The failure of the Municipality at any time to enforce a provision of this
Agreement shall in no way constitute a waiver of the provisions, nor in any way affect
the validity of the Agreement or any part hereof, or the right of the Municipality
thereafter to enforce every provision hereof.
5. Amendment. This Agreement shall only be amended by authorized representatives of
the Owner and Municipality. Any attempt to amend this agreement by either an
unauthorized representative or unauthorized means shall be void.
6. Jurisdiction: Choice of Law. Any civil action arising from this Agreement shall be
brought in the Superior Court for the Third Judicial District of the State of Alaska at
Anchorage. The laws of the State of Alaska shall govern the rights and obligations of the
parties under this Agreement.
7. Severability. Any provisions of this Agreement decreed invalid by a court of competent
jurisdiction shall not invalidate the remaining provisions of the Agreement.
(rev. 05/18/2018) Page 2 of 3
DocuSign Envelope ID: 4A9DB65A-C781-48D3-885B-4E521484FC50
OWNER:
By: _ 1_ (signature) Date:. �- r~,y�,� a C/
H fi 1 A L-b (print name)
STATE OF ALASKA )
ss.
THIRD JUDICIAL DISTRICT )
The foregoing instrument was acknowledged before me this day of J un2
20A,by `ockeQtq )-or
01
J,` t
o.fAlaska
NQTARY 1'UBLi 'FOR ALASKA State
My Commission expires: — u --,),O;� NOTARYPUBLIC
Qrade Hanneman
My Comft1cn EVIms Apr 10, 2027
MUNICIPALITY
r
By: �� (signature)
7D L,,-5 (%" (print name)
Date: t/a),2'
Title: C t v? (--
C'-4 (";, 7 /Z
(rev. 05/18/2018) Page 3 of 3
Municipality of Anchorage
On -Site Water & Wastewater Program
(907)343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL
Parcel I.D. 015-192-04 Expiration Date: 1.1-141-13
1. GENERAL INFORMATION
Complete legal description TRAILS END; BLOCK 7 LOT 2
Location (site address)
Current Property owner(s)
Mailing address
Real Estate Agent
2. TYPE OF DWELLING:
11441 BROWDER *ANCHORAGE AK 99507
BJARNE & ROBIN HOLM Day phone
11441 BROWDER *ANCHORAGE AK 99507
AUDREY MASON Day phone
N Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
346-3910
632-0573
3. NUMBER OF BEDROOMS:
3
4. TYPE OF WATER SUPPLY:
TYPE OF WASTEWATER DISPOSAL:
Individual Well
Individual On-site
0
Individual Water Storage
❑
Individual Holding tank
❑
Community Class Well
❑
Community On-site
❑
Public Water System
❑
Public Sewer
❑
Received by: 2- Date:
COSA to be released to the engineer, unless otherwise requested by the engineer.
COSA Fee $ _ q O
Date of Payment r cJ l I
Receipt Number 0ouk 3r+�
COSA # neD ' l
Waiver Fee $
Date of Payment
Receipt Number
Waiver #
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. 1 further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system in accordance with ADEC and MOA
DSD Guidelines & Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the test, and separation
distances measured to readily identifiable features. The operational life of all wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Satisfactory test
results do not guarantee future performance of the system, nor do they guarantee that
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC or MOA DSD. The content of this report is for
the sole benefit of the owner listed above. Any reliance upon or use of this report by any
other person or party is not authorized, nor will it confer any legal right whatsoever.
6. DSD SIGNATURE
_System #1 Approved for bedrooms.
System #2 Approved for bedrooms.
Disapproved.
Conditional approval for bedrooms, with the following
Phone 337-6179
Date - Z o,
-c
�.....,... . x,
A. r ess
CE 3 .•'
ttll
OF
ON-S►TE
VVATER AND
" E
PROGRAM
Original Certificate Date:�t J
The Munrcipalo or A, age Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska.
The Municipality of Anchorage is not responsible for errors or omissions in the professional engineers work.
7. ATTCHMENTS:
COSA Checklist
Septic System Advisory
Well Flow Advisory
ram ivnel
Nitrate Advisory
Arsenic Advisory
Other
If more than 1 septic system is on the lot:
COSA Checklist # of
Structure served by this system
Certificate of On -Site Systems Approval Checklist
Legal Description: TRAILS END; BLOCK 7, LOT 2 Parcel ID: 015-192-04
A. WELL DATA
Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (YIN) YES
Date completed 10/19/83 Sanitary seal (Y/N) YES Wires properly protected (YIN) YES
Total depth 160 ft. Cased to 159 ft. Casing height (above ground) 12+ in.
FROM WELL LOG
Date of test 10/19/83
Static water level
Well production
AT INSPECTION
7/17/13
ft. 60 ft.
g.p.m. 2.4+ g.p.m.
WATER SAMPLE RESULTS:
Coliform U colonies/100 ml. Nitrate L S L mg./L. Collected by: GEG. Ltd.
Arsenic: N P ug./L. Date of sample: 7/17/13
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material SEPTIC/STEEL Date installed 4/20/84
Tank size 1000 gal. Number of Compartments E Cleanouts (Y/N) YES
Foundation cleanout (Y/N) YES Depression over tank (Y/N) NO High water alarm (YIN) N/A
Date of pumping 6/7/13 Pumper ONE STOP PUMPING
C. ABSORPTION FIELD DATA *BELOW EXISTING GRADE
Date installed 4/20/84 Soil rating (g.p.d./ft2or /bdrm 290 System type BED
Length 24 ft. Width 56 ft. Gravel below pipe 0.5 ft.
Total depth 5.08 ft. Eff. absorption area 1344 ft' Monitoring tube YES Depression over field NO
Date of adequacy test 7/17/13 Results (Pass/Fail) PASS For 3 bedrooms
Fluid depth in absorption field before test 0 in. Water added 4�0 gal. New depth E in.
Elapsed Time: 0 min. Final fluid depth E in. Absorption rate >= 450+ g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) TERRALIFTED If yes, give date 6/12/13
THERE ARE NO C/O'S IN THE BED, ONLY A SINGLE MT. BOTTOM OF MT IS 0.62 FEET LOWER IN
ELEVATION THAN THE POST TANK C/O.
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N
"Pump on" level at in. "Pump off' level at—====r High water alarm level
Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tankilift station on lot 100,+ On adjacent lots 100'+
Absorption field on lot 100'+ On adjacent lots 100'+
Public sewer main N/A
Sewer /septic service tine 25'+
Animal containment areas 50'+
Public sewer manhole/cleanout N/A
Holding tank N/A
Manure/animal excrete storage areas 100'+
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line 5'+ Absorption field 5'+
Water main N/A Water service line 10'+ Surface water 100'+
Wells on adjacent lots 100'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Properly line 10'+ Building foundation 10'+ Water main N/A
Water service line 10'+ Surface water 100'+ Driveway, parking/vehicle storage 10'+
Curtain drain NONE KNOWN Wells on adjacent lots 100'+
F. COMMENTS
G. ENGINEER'S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Pr dName JEFFREY A. GARNESS
Date /I 2-' i
(Rev. 11/05)
OF
,J fr Ga ess:.
-E 7 . �
bL r
V
'V
1
pm,.'c3w
m
.1 lVi
C CD 9
M Z
�� +�
Cr aC�
�•, P��
z
Alt
r
a
S Y
TO
ALASKA STATEWIDE TERRALIF€
'The EorMsholrlrtg solIdlon for Problem Soils"
4212 Harca St., Eagle Raver, Alaska 99577
907-622-7153
2182
RAY WORK
TERMS-
T#TY..i . � � ;.OATEkIAL..'
Wit GYFAMMC
®I-"=
TOTAL MATERIALS
VES s+ RIP'tION OF WORK
TOTALOTHER
TOTALLABOR
TOTAL MATERIALS
TOTAL OTHER
Worhor6eredby
%�Yfril�iiTC/�C� T
Signature
I ",-byaCmrnskA9e 41e sati5lartory ccmP�tion W €he atwve daectiUed work. T "
k -s7
O
MUNICIPALITYHEA OF TH& ANCHORAGE
• DEPARTMENT OFFHEALTH &HUMAN SERVICES
Division of Environmental Services
On -Site Services Section
P.O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
CERTIFICATE _OF -HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
Parcel I.D. # 01 5— 142 — O U
1. GENERAL INFORMATION
2.
3.
4.
�� •.li ` •
Complete legal description Loi 42, BV, 7 i 1? A. I Lg I= N iI
Location (site address or directions) 11 44 t QouUD t-- r2
Propertyowner 40Lt-4( S 3A4t Day phone 3+1b— 3g/o
Mailing address
Lending agency
Mailing address
Agent
Address
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
Individual well
Community well
Public water
Day phone
Day phone
9 "" Imo
P51�
NOTE: If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system.
TYPE OF WASTEWATER DISPOSAL:
Individual on-site v
Holding tank
Community on-site
Public sewer
NOTE: If community wastewater system, provide written confirmation from State ADEC
attesting to the legality and status of system.
72-025(R".1/91) Front MOA#21
S. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further verify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firmi m 46e H Phone
Address
Engineer's signature
6. DHHS SIGNATURE
Approved for
Disapproved.
Conditional approval for
Additional Comments
bedrooms.
Date '/ %9 Y
following stipulations:
Date
The Municipality of Anchorage Department of Health and Human Services (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
n.M(Bev.1N1) Balk MOA821
C. LIFT STATION
Date installed Manufacturer
Size in gallons Manhole/Access (Y/N)
Vent (Y/N) "Pump on" level at "Pump off" Level at
High water alarm level Cycles tested
Meets MOA electrical codes (Y/N)
SEPARATION DISTANCE FROM LIFT STATION TO:
Well on lot On adjacent lots Surface water
D. ABSORPTION FIELD DATA
Date installed va /G • 2-Y Soil rating (GPD/Ft) A Q O System type 73 EU
Length g ('0 Width 2 Gravel thickness d It Total depth 5 IF
Total absorption area 13Y V Cleanout present (Y/N) _Depression over field (Y/N)
Date of adequacy test 2 to Results (pass/fail) for Bedrooms
r/
Water level in absorption field before test b 0 After test b
Peroxide treatment (past 12 months) (Y/N) nI If yes, give date
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot 1.2S On adjacent lots ? X00 Properly line 44
To building foundation _> 10 To existing or abandoned system on lot —V
On adjacent lots >30 Cutbank N O A t Water main/service line i 50
Surface water N 0 heff Driveway, parking/vehicle storage area > 6c
Curtain drain�[�
E. ENGINEER'S CERTIFICATION
I certify that l have checked, verified, or conformed to all MOA and HAA guidelines in
Signature
Engineers Name I glob_-- ui c`
Date
HAA Fee $ 1300 • UD
02
Date of Payment
Receipt Number
72-026 (6193)' Back
oil
Waiver Fee $
Date of Payment
Receipt Number.
Q11V% to of this inspection.
OFA4. `11
,en Spurkland
CE -2225
� �OFESS��`®
® Municipality of Anchorage
aim
• Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: L 2, BK 1 1 roK I4 iN ef Parcel I.D. 0/
A. Well Data
Well type If A, B, or C, attach ADEC letter. ADEC water system number
Log present (Y/N) Date completed 1*11q 9' Driller 4 r tJ, 014 / 7A;:
Total depth )/•O Cased to />; 9 Casing height A1.
Sanitary seal (Y/N)
Wires properly protected (Y/N)—E
FROM WELL LOG
AT INSPECTION
/�
A
n
Date of test
l 0 •1 Q • 8�
' l G • 4 y
rn
C7
�,
M
1'71
ry
Static water level
Ll 7
%C
Well flow
'S
g.p.m.
g.p.m.
ry-1
4�-
1 �b
> 13`�
v
<i
Pump levell
y c
O II
Z
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot
//S
; On adjacent lots i
1 rrt�
Absorption field on lot
1 •Z5
; On adjacent lots i
1OO
Public sewer main
Iy/i4
Public sewer manhole/cleanout
W/A.
Sewer service line
1 rD
Petroleum tank W C
✓1 *--
WATER SAMPLE RESULTS:
Coliform Nitrate 6.Ii�;rtOther bacteria
-
Date of sample: r� • / L r 4 y Collected by: -T-7.%
B. SEPTIC/HOLDING TANK DATA
Date installed #2Ua -Tank size I Compartments 'ice
Cleanouts (YM) Foundation cleanout (Y/N) 7V
Depression (Y/N)
High water alarm (Y//N) N�/�- Alarm tested (Y/N) ' onA
Date of pumping, W) 1113 Pumper A
11 J
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
Well(s) on lot 11.5 On adjacent lots i 1 B{7 Foundation 10
To property line 1 10 Absorption field h Water main/service line _i �6 D
Surface water/drainage qh
72-026(U3)'From CONTINUED ON BACK PAGE
T
00
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information
Application Date
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot 2 B-ock 7 Trails End Subdivision
Location (address or directions)
(b) Applicants Name Fejes Development 1blephone
Applicants Address
(c) Applicant is (check one) Lending Institution Owner/builder xx ;
Buyer Other � (explain);
(d) Lending Institution Rainier. Mortgage % Linda Telephone
Address
(e) Real Estate Co. 5 Agent Banner Realt
Address
Telephone
2. Type of Residence
Single -Family EEKI Multi -Family Other (describe
Number of Bedrooms three
3. Water Supply
Individual Nkll r—x—xl Commanity � Public
Note: If community well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
Is the well adequate for the number of bedrooms specified in this HAA (YM)
4. Sewage Disposal
Onsite Eli
Public r:::� Comaunity Holding Tank
Is the wastewater disposal system adequate fcr the rumber of fedrooms (YM)
[Page 1 of 21
2-15-84
5. Engineering Firm Providing Inspections, Tests, Data and Information
I certify that I have checked, verified, or conformed to all MDA HAA Guidelines in
effect on the date of this inspection.
Signed Date
Name of Firm Telephone
Address
Signed by
Date
(ENGINEER SEAL)
6.DHEP Approval
Approved for three bedrocm
Approved � Disapproved
Terms of Conditional Approval
The engineer(A.E.C.S.) has
confirmed the conditions set
forth have been completed and
documentation is on file with
this Department. This property
is now fully approved and meets
with MOA Ordinances and codes.
By (LWa-[ Date July 9, 198
Conditional
The Municipality of Anchorage Department of Health and Environmental Protection does
not guarantee the continued satisfactory performance of the water supply and/or the
wastewater disposal system. This approval indicates that, as of the validation date
shown above, based on the data and information furnished by an engineer registered in
the State of Alaska, the water supply and wastewater disposal system is safe and funr
tional for the number of bedrooms and type of structure indicated.
(DHEP SEAL)
7. Mail the HAA to the following address:
KB2/d5/s
(Page 2 of 21
2-15-84
of
MUNICIPALITY OF ANCHORAGE
DIVISION OF ENVIRONMENTAL HEALTH
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
APPLICATION FOR HEALTH AUTHORITY APPROVAL CERTIFICATE
1. General Information
(a)
(incline lot, block,
L>//1 f L
T
Location (address or directions)
(b) Applicants
Applicants
Application Date
section, tainSship, range)
(c) Applicant is (check one) Lending Institution Owner/builder ;
Buyer Other r:::j (explain);
(d) Lending
Address
(e) Real Estate Co. & Agent eL�e (_ T
Address ( `' , l / lr. Y"� : r
Telephone
2. Type of Residence
Single -Family
L7:"
Number of Bedrooms
3. Water Supply
Multi -Family
i
Other
Individual ill = Community Public
Note: If community. well system, must have written confirmation from the State
Department of Environmental Conservation attesting to the legality and status.
Is the well adequate for the number of bedrooms specified in this HAA (YM) Y
4. Sewage Disposal
Onsite � Public Ccmminity Holding Tank
Is the wastewater disposal system adequate for the number of bedrooms (Y/N) Y
(Page 1 of 21
M4=011
•0
�s
5.,Engineering Firm Providing Inspections, Tbsts, Data and Information
B certify that I have checked, verified, or conformed to all MOA HAA Guidelines in
effect on the date of this inspection.
Date I
Name of Firm CS -77"U4
Address (?c'v 33r,1 /�Lyc S✓-) R-eC-O MvVkd CvK 46`bKal orP1
Signed by id\- LaVJSC[�)ol Nj c. -j "S14 1 f s a P WAFert
Date /9 1
(ENGINEER SEAL)
6.DHEP Approval
Approved for - bedroc s
Approved
Disapproved P,
Conditional
The Municipality of Anchorage Department of Health and Environmental Protection does
not guarantee the continued satisfactory performance of the water supply and/or the
wastewater disposal system. This approval indicates that, as of the validation date
shown above, based on the data and information furnished by an engineer registered in
the State of Alaska, the water supply and wastewater disposal system is safe and func-
tional for the number of bedrooms and type of structure indicated.
(DHEP SEAL)
7. Mail the HAA to the following address:
KB2/d5/s
[Page 2 of 21
2-15-84
f40
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
A. WELL DATALegalZ 13
Legal Description: �K -1
_V4:IS ttJp SubdiViS Ion/
Well Classification -xua w;d.Aa) If A, B, cr C, D.E.C. Approved(Y/N) N// -
Well Log Present a) Date Completed OCi )`{� /Q �3 Yield 5 q
em
Total Depth Cased to I Depth of Grouting uN8
Static Water Level 4-7-4- Pump Set At
Casing Height Above Ground ).$ �4- Sanitary Seal on Casing &N—)
Electrical Wiring in Conduit Ay" Depression Around Wellhead (YAQ
Separation Distances from Well:
To Septic/Holding Tank on Lot i On Adjoining Lots GT /oo,�I-
To Nearest Edge of Absorption Field on Lot 125- ; On Adjoining Lots CrT/ooft
To Nearest Public Sewer Line N 'Gl- To Nearest Public Sewer
Cleancut/Manhole N//� To Nearest Sewer Service Line on Lot N/
Water Sample Collected By n GooDcnl ; Date 13 m4q84 11:30pw1
Water Sample Test Results
Counts
B. SEPTIC/HOLDING TANK DATA
1,l,1e 14"I'l 2
Date Installed y - to Size /C)Or) No. of Carpartments 2 -
Standpipes
Standpipes (Y/N) Y Air -tight Caps (Y/N) Foundation Cleanout (YIN)
Depression over Tank (YM) jJ Date Last Pumped
Pumping/Maintenance Contract on File (YM) — ; for ---
Holding Tank High -Water Alarm (YM) Temporary Holding Tank Permit (YM)
Separation Distances from Septic/Holding Tank:
To Water -Supply 4 11 IIJ 44- To Building Foundation
To Property Line To Disposal Field (y�l
To Water Main/Service Line s- To Stream, Pond, Lake, or Major Drainage
Course GT 1 oo 4-
'� i
(Page 1 of 21
2-15-84
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata Type of System Design 561161 lbee(
Date Installed �j , -Lo -14 Length of Field SG 10 -
Width of Field y,( -t JL Depth of Field (p i H
Gravel Bed Thickness
Square Feet of Absc ption Area Standpipes Present (Y/N) �(
Depression over Field (Y/N) Y Date of Last Adequacy Test
Results of Last Adequacy Test
Separation Distance from Absorption Field:
To Water -Supply Well
( Z
To Property Line / 1.Z2
To Building Foundation
2 L
To Existing or
Abandoned System cn
Lot
Or. Adjoining Lots
CGT /auk
To Water Main/Service Line
—
To Cutbank(if
present)
To Stream/Pond/Lake/or Major
Drainage
Course G T
/ Op i_1—
To Driveway, Parking Area, or Vehicle
Storage Area
S C(� f -
Convents GrwUwo _,oW VtYurncFo CuN,15caWl'
D. LIFT STATION
J
Date Installed _ Dimensions
Size in Gallons Manhole/Access (Y/N)
"Pump On" Level at "Pump Off" Level at
High Water Alarm Level at
Tested for
Electrical Codes(Y/N)
-� Vent (Y/N)
Pumping Cycles during Adequacy 'Inst. Lets MOA
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checked, verified, or conformed to all M
on the date of this etion.
Signed ) Date
Company / t C -S MOA
KB1/d5/s
[Page 2 of 21