ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Eel
�..,1y
Page /of
Permit Number. SW010456
Name:
MM&M Contracting. Inc.
Add.:
PO Box 670495. Chugiak. AK 99567
Phone
688-1236
Block:
2
Township:
Well:
Number of B.dmons:
4
LEGAL DESCRIPTION
Lot SWmnuon:
4 GLENN VW. ESTATES WEST PH 2
RAMA Section:
0 New 0 Upgrade
Classification (Pinata, /1/413, CI:
Public
YAW:
Taal Dear: IGesd to:
FI. FL
Dee Dived:
static Water Level:
Ft.
I Pump Set et I Cava Hewn Above Ground:
Fl
GPM FL
SEPARATION DISTANCES
To Septic
From Tank
Absorption
Field
Wel 200'+ 200'+
Surface Water 1001+ 100'+
La Ln. 5'+ 10'+
Foundabon 5'+ 10'+
Curtain Drain NA *50'+
Remarks:
*none known
Field Insulated
Lift
Station
NA
NA
NA
NA
NA
Holding
Tank
NA
NA
NA
NA
NA
Inspections performed by: KND Engineering, Inc.
PublidPrivate
Sewer Line
25'+
PID Number. 051.793.25
Wastewater System: ® New 0 Upgrade
ABSORPTION FIELD
0 Deep Trench as Shallow Trench 0 Bad 0 Mound 0 other.
So. Rating:
0.8 GPO/Fe
Depth to ppe bonen from original grads:
2.5
FA added above anginal grade:
0.88-6.59+/-
Grh.l ,dth:
5
Total abwpbar area:
800
Installer:
Turner Const.
FI.
FI.
FI.
Fr
Taal Depth from orgn.r grade:
4.5
Gravel depth ban .th pp.:
2.0
112
Gravel Length:
FI.
FL
Ft.
Number of Mian: I Distance between nes:
2 10+
Pips Ma4aW:
SCH40 & F810
Date Mulled:
TANK
S Septic 0 Holding 0 S.T.E.P.
MmutaUuer:
Greer Tank
Maimed
Steel
Sae.
'Pump on' level aL
Pump Melia S Model
LIFT STATION
Manufacturer.
Gel.
'Purim olf level aL
In.
Location and Desolation:
Bottom of siding
Dates:
11/28/01
Ebancal Inspections p.do mad by
BENCH MARK
1" 11/28/2001
2md 11/28/2001 e" '• me none
Development Services Department Approval 34/0140C 91 « ••••-•••••
/d tie; Kenn.
Ft.
0 Other.
cap.cay:
1250 cel.
Number a Compartments:
2
High water alarm aL
Assured Lavation.
100 FL
Engineer's Stamp
E OF AC''''11
S�Q� ••''....ee•ee 421
•%.'4
"5
•r_ Q
.g;• • .
Reviewed and approved by:
(Rev.lZaol
/c/ re -et
Date: /6 - 3 / -o3 14 Nom'. Ce 71
AS -BUILT SYSTEM DETAILS/SITE PLAN Permit SW010456
GLENN VIEW ESTATES WEST VD, LOT 4, BLOCK 2 PID#051-793-25
A -C= 28.0'
B -C= 24.0'
A -D= 29.6'
B -D= 28.4'
A-E= 26.6'
B-E= 62.4'
A -F= 58.3'
B -F= 41.3'
A -G= 40.9'
B -G= 73.6'
A -H= 67.7'
B-H= 57.9'
A -I=42.4'
B -I=51.8'
TOR TutC MONITOR Tut(
FINAL GRADE
It✓IY'Iv-1 -. n .I C�ICI4��Ly�(yy
fart. IMM:\ 'MytATIOM
SCALE:
ArS-Ci.PF A4
fed.
NTS
SEWER ROCK
TRENCH 1
56
Ilt of47
Il FINAL GRADE
rauknufrnwmuliIii±rn-� IL I�
fLK1IMlG\ /M4LLfip1
L
IOM: TCR
IRK =TMCIT
SEWER ROCK
TRENCH 2
YAMS
r
7 X89 3 89.3
I
>� II CIIJILy II It-IIF-IIHII--III--IIHIFyll�ltj
56'I < 80.75)
PREPARED FOR:
REX TURNER
ARCTIC DEVCO, INC.
P.O. BOX 3489
PALMER, ALASKA 99645
FIELD BOONS GNAWED:
eek."" SEWARD
STAMM*
AgIU" LANG 10/29/02
oM6. nc: NW1459
ACAs nc: 01101.DWG '08 M' 01101
MAU .
VBG
ocacm KMD
OAR
GRIM
SCALE:AL�D
NTS
}}
J11��,dV ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
11
(907)898-8111/FAX (907)898-8111
1K„iV ID ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
1
SOILS PERCOLATION TEST
Performed fon. Turner Construction
Project: Glenn View West Est. Ph2,132, L4
Depth
(Feet)
is ORG — brown overburden
1
2 a ..r
GM/GP — med dense, brown
w/ cobbles
6-
7-
8-,
B.0.11.- Bottom of trench
Material consistent along trench.
9-
10-
11-
12-
13-
14-
15-
16-
17-
18-
19-
1IOLE PRESOAKED
20- PRIOR TO TEST
OF
iSCP; .••'".......,, .er
4. 's *
•
'
4W
�I f•,� C'e 711'FI : ��
le �pROFEss0.1
Date Performed: 117S1431..".4g*
TEST HOLE # 01-1
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Was Ground water encountered? NO
Depth to water after monitoring? NO
What depth? NA
Date? NA
Reading Date Gross Net Depth to Net
Time Time Water Drop
1 11/28/01 1:00
2 1:10
3 * 1:11
4 1:21
5 e 1:22
6 1:32
7 ' 1:33
8 1:43
9 • 1:44
10 1:54
11 • 1:55
12 2:05
' Water Added
6" -
10 min 212/16" 3 4/16"
6"
10 min 2 15/16" 3 1/16"
6"
10 min 3" 3"
6"
10 min 3 2/16" 214/16"
6"
10 min 3 1/16" 2 15/16"
6"
10 min 3 1/16" 2 15/16"
Percolation Rate 3.4 (min/in) Pere Hole Diameter 6"
Test Run Between 4.5 feet and 5.5 feet
1, Kenneth M. Duffus, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
/ T 7#%p(c rroii
11- 28 - 0 / /EDO q, et,
2=
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Initial
Date Issued: Oct 31, 2001
Expiration Date: Oct 31, 2002
Permit Number: SW010456 Parcel ID: 051-793-25
'Legal Description: GLENN VIEW ESTATES WEST PH 2 BLK 2 LT 4
Design Engineer: 0070 KND Engineering Site Address:
Owner Name: Tumer Construction Lot Size: 40881 SO. FT.
Owner Address: PO Box 3487 Total Bedrooms: 4 Permit Bedrooms: 4
Palmer , AK 99645 -
This permit is for the construction of:
G Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well • 0 Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 (24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Received By:
Issued By:
Date: *VC) l
Date: ( /4(
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. O5/-793— l s_
Property owner(s) Turner Construction
Mailing address (1) PO Box 3487. Palmer.AK 99645
Mailing address (2)
0
i t y
Permit Number SW 0 I d tiSfo
Day phone 242-4555
Zip Code
Legal description (Lot, Block & Sub'd.) Glenn View Estates West. Phase 2. Block 2. Lot 4
Legal description (Section, Township & Range)
Lot Size 40,881 Acres/Sq.Ft. Number of Bedrooms 4
THIS APPLICATION IS FOR:
Sewer Only ® Well Only
Sewer and Well 0 Water Storage
Sewer Upgrade 0
THIS PROPERTY CONTAINS:
Hot Tub • 0 Jacuzzi
Swimming Pool 0 Water Softening Unit
Therapy Pool ❑
0
0
certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: 't 320 Waiver Fees:
Date of Payment: 10123/OI Date of Payment:
Receipt Number: 111513 `/_. Receipt Number:
(Rev. 12/00)
AK.dV`' D ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
U
(907)696-6111/FAX (907)696-8111
October 22, 2001
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: New sewer permit — Glenn View Estates West Phase 2, Block 2, Lot 4
Gentlemen:
The owner has requested we proceed forward to obtain a septic permit on the subject
lot. On April 19, 1999 one testhole was excavated for the proposed septic system. The
result of the test is attached. The general slope of this lot is flat or of moderate slopes
from northwest to southeast at a grade of approximately 3 - 7%. We have designed our
system utilizing the testhole we excavated for the 4 -bedroom house, which is proposed
for this lot. The lot will be served by public water. We propose to install a 5' wide
shallow trench. Water was not encountered during the excavation or monitoring.
There are no public or private wells within 200' of our proposed system location except
as noted. There is no surface water within 100' of the proposed system and there are no
known curtain drains within 50'. We do not expect there to be any adverse effect on
adjacent lots by the development of this system.
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully submitted,
END Engineering
Kenneth M. Duffus, P.E.
Attachments: On -Site Sewer Application
Wastewater Absorption System Details/Site Plan
Soils Log/Percolation Test
WELL & WASTEWATER DISPOSAL SYSTEM DETAILS/SITE PLAN
GLENN VIEW ESTATES WEST S/D, LOT 4, BLOCK 2
L
KND Lot 9
S
Lot 8
• •
Lot 3
NINIgtop
s
S a 1116 St
Lot 4
Lot 7
Lot 6
AO PUBIC WELLS WITHIN $00' Cr
PROPOSED SYSTEM
PC PRIVATE YELLS WITHIN ;!00' CA
PROPOSED ST$TCH EXCEPT AS ROTCD
PC SEPTIC SYSTEMS WITHIN E00' Of
PROPOSED VCLL EXCEPT AS NOTED.
���. DF' 4444,5
.9I
DUV'S
'''£ss101414,' ../
CE -7116
DESIGN DETAILS
4 BDRM X 150 GPD = 600 GPD
600 GPD/.8 GPD PER SO. FT. (1.6 MIN/IN.)= 750 S0. FT
(750/5'(V)) X .70(RF) (2.0' GRAVEL) = 105 FT. TRENCH
USE 2 TRENCHES - 53 (L) X 5' (V) X 2.0'(D)
Total depth of system is 4.5' from original grade.
Total depth of grovel below distribution pipe is 2.0' .
NOTES: •
1. USE 1250 GAL SEPTIC TANK AND INSULATE 1F LESS THAN4' OF COVER.
MAX BURIAL DEPTH = 4' OF COVER.
2. INSULATE TRENCHES WITH 2' HD BURIAL FOAM.
3. CONTRACTOR VILL ENSURE MINIMUM 2% SLOPE INTO SEPTIC TANK.
4. ADDITIONAL FILL VILL BE ADDED OVER SYSTEM TO ACHIEVE
MIN. 3' COVER IF REOUIRED.
5. CONTRACTOR VILL ENSURE ALL SEPARATIONS TO ADJACENT
WELLS, SEPTICS. LOT LINES, FOUNDATIONS AND ALL OTHER SETBACKS.
PREPARED FOR:
REX TURNER
ARCTIC DEVCO, INC.
P.O. BOX 3489
PALMER, ALASKA 99645
FIELD 8004(5 Ca JTED:
DRAWN: VBG
ocLRED KMD
"JaR" sEWARD
SEWARD
SEWARD
CAC fu
STAKING
ASDtRT:
I DATE
I
Aum RC: 01101.DWC 'DDR"'
10/30/01
NW1459
Scale: 1'= 100'
PAGE 1 OF 2
LEND ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
01101 (907)898-8111/FAX (907)698-8111
eD 4
'OUSE
WASTEWATER DISPOSAL SYSTEM DETAILS
GLENN VIEW ESTATES WEST 5/1), LOT 4, BLOCK 2
FCO
69'
PROPOSED 1250 GAL
SEPTIC TANK
CO
ZABEL Z200
FLOW DIVIDER
29' I ti/ 1C'
SCO CO --
MT
MT# O CO
4i
=9-2/4 Lot
NT
11'
a CIF 44S ‘
4,4 "Pr..*/
KENNETH N. DU
CE -7118
•ilf
••...s_
wAir
'TiSS1oNo•I'
PREPARED FOR:
REX TURNER
ARCTIC DEVCO, INC.
P.D. BOX 3489
PALMER, ALASKA 99645
FIELD BOOKS I
1
1
°0LO"" SEWARD
s'"""' SEWARD
A" SEWARD
ow. nu:
""D ru` 01101.DWG
caw¢a
anew: VBG
ammo: KMD
Del[:
uo
XS NS:
10/30/01
NW1459
01101
Scale: 1'= 20'
PAGE 2 OF 2
"END ENGINEERING
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907)898-8111/FAX (907)698-8111
KND ENGINEERI ;
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
!y, ' ;. - x_ :'til. wd1_i_2 1p
Performed fon
Project:
Depth
(Feet)
15-
16-
17-
18-
19-
20-
..r` v• ?'L4!l1
V •:::1,011
or •�1 !���',�. X91/
'/*ztir9Th _S */et
..
./ .
-"x_31- ._ter —
itrS_ r co tenth
rxt
�em Cr7116
Date Performed: 04/1
SOILS PERCOLATION TEST
Arctic Devco
Lot 4, Block 2, Glenn View West
ORG — black rootmat
SM — w/ some rootmat
GM/SM loose to med. dense,
med. dense to bottom
B.O.H.
HOLE PRESOAKED
PRIOR TO TEST
IWas Ground water encountered? NO
TEST HOLE 11 99-2/4
SEE ATTACHED SITE PLAN
FOR HOLE LOCATION
Depth to water after monitoring? NO
What depth? NA
Date? 05/15/99
Reading Date Gross Net Depth to Net
Time Time Water Drop
1
2
3
4
5
6
7
8
9
4/19/99 4:15 10" -
4:25 10 min 24/16" 712/16"
• 4:26 10" -
4:36 10 min 212/16" 74/16"
• 4:37 - 10" -
4:47 10 min 3 4/16" 612/16"
• 4:48 10" -
458 10 min 312/16" 64/16"
• 459 - 10"
10 5:09 10 min 312/16" 64/16"
11 • 5:10 10"
12 5:20 IO min 312/16" 64/16"
Water Added
Percolation Rate 1.60 (min/in) Pere Hole Diameter 6"
Test Run Between 4 feet and ;t feet
I, Kenneth M. Chaffin, certify that this test was performed in accordance with all State and Municipal guidelines in
effect on this date.
JKND ENGINEERING, INC.
20441 PTARMIGAN BLVD.
EAGLE RIVER, AK 99577-8736
(907) 696-6111/FAX (907) 696-8111
April 26, 2002
Municipality of Anchorage
Development Services Department
On -Site Water & Wastewater Program
P.O. Box 196650
Anchorage, AK 99519-6650
Subject: Inspection Report Delays - Glenn View Estates West
Gentlemen:
The on-site septic systems listed below have been installed as permitted. At
present, we have not received the as -built surveys from the property owner and
we are unable to submit the inspection reports. Once we have obtained the
needed information from the property owner, we will submit the inspection
reports and all other required documents for your review and approval.
• `Glenn View Estates West Lot 3, Block 11
• Glenn View Estates West Lot 11, Block 1
Glenn View Estates West Lot 4, Block 2
• Glenn View Estates West Lot 8, Block 2
• Glenn View Estates West Lot 3, Block 2
If you have any questions, please contact me at 696-6111/FAX 696-8111.
Respectfully,
MD Engineering, Inc.
rent M. Western
cc: file
Municipality of Anchorage KtulK LOcie (
Development Services Department V
Building Safety Division
On -Site Water 8 Wastewater Program
. 4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519.6650
www.muni.orglonsite
(907) 343-7904
CERTIFICATE OF. ON-SITE SYSTEMS APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel 1.13. -025
1. GENERAL INFORMATION
Complete legal description
Location (site address)
Current Property owner(s)
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing address
COSA# O(r,hDR
Expiration Date: 3 - a. a— 07
WEST"
GLENN VIEW EST. PHASE 2, LOT 4, BLOCK 2,
21241 PAULA SUE CIRCLE • CHUGIAK, AK 99567
ROBERT & BARBARA EVANS
P.O. BOX. 772432
Day phone 250-4630
Day phone
REGAN RUSSEY w/REALTY EXECUTIVES Day phone 244-0225
341 W. TUDOR ROAD. SUITE 103 * ANCHORAGE. AK 99507
Unless otherwise requested, COSA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS: 4
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
0
•
TYPE OF WASTEWATER DISPOSAL:
Individual On-site
Individual Holding tank
Community On-site
Public Sewer
0
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems
Approval (COSA) based only upon the representations given In paragraph 4 by an independent professional civil
engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer
of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or
water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems
Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may
be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water
samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system.
The Municipality of Anchorage Is not responsible for errors or omissions in the professional engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, 1 verify that my I cation,
investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this app
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the
information obtained from the Municipality of Anchorage files and from my investigation and inspection, the
on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal
and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm GARNESS ENGINEERING GROUP, Ltd.
Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507
Engineer's Printed Name JEFFREY A. GARNESS, P.E.
Engineer's Comments:
In conducting this evaluation, GEG, LtD. attempted to provide a thorough,
conscientious engineering analysis of the system In accordance with ADEC and MOA
DSD Guidelinos B Regulations. The reported results described the performance of the
system under the conditions encountered at the time of the fest, and separation
distances measured to readily Identifiable features. The operational life of ell wells and
septic systems depend on the local soils condition, groundwater levels that may
fluctuate during the year, and the water usage of the family being served by the system.
These conditions are outside the control of the evaluator of the system. Sat isfa � test
results do not guarantee future performance of the system, nor do they guarantee
there are no hidden defects or encroachments. GEG, LTD. can therefore not provide
any warranty or future estimate of how long the system will continue to meet the
operational requirements of the ADEC a MOA DSD. The content of this report is for
the sole benefit of the owner listed above. My reliance upon or use of this report by any
other person or party Is not authorized, nor will ft confer any legal right whatsoever.
5. DSD SIGNATURE
Approved for L.1 bedrooms.
Disapproved.
Conditional approval for
Phone
Date
337-6179
bedrooms, with the Mowing stipulations:
`; • ON-SITE ..-.17c/r-
t
:� _
• m.
. WASTEWATFR
trtrivATEFAND
o•••• PROGRAM
Attachments:
COSA Checklist
Septic System Advisory
Well Flow Advisory
Nitrate Advisory
ey
Arsenic Advisory
Maintenance Agreements
Supplemental Engineer's Reort
Other
/R-, 11M1
stwv-
Original Certificate Date: 3 - 02 2- 0 6
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water 6 Wastewater Program
4700 Bragaw Street
P.O. Box 196650
Anchorage, AK 99519-6650
Www.muni.org/onsite
(907) 343-7904
CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST
we5r
Legal Description:
A. WELL DATA
Well type
Date completed
Total depth
GLENN VIEW EST. PHASE 2, LOT 4, BLOCK 2,
PUBLIC WATER
If A, B. or C provide PWSID# Well
Sanitary seal Y . Wires properly protected (Y/N)
Cased to ft Casing height (above ground) in.
AT INSPECTION
Parcel ID:
Date of test
Static water level
Welt production
FROM WELL LOG
/ ft.
WATER SAMPLE RESULTS:
Coliform
Arsenic:
B. SEPTIC/HOLDING TANK DATA
Spm
colonies/100 ml. Nitrate mgJL.
Date of sample.
Tank Type/Material
Tank size 1250 9aL
SEPTIC / STEEL
Number of Compartments 2
/ ft.
gpm
Foundation cleanout (Y/N) YES Depression over tank (YIN) NO
Date of pumping 3/14/2006 Pumper
C. ABSORPTION FIELD DMA
Date Installed 11/25/2001
Length 112 ft.
colonies/100 mi.
Collected by:
Date installed
11/28/2001
Cleanouts (Y/N)
YES
High water alarm (Y/N) N/A
JR's PUMPING
I'BELOW EXISTING GRADU
Soil rating (g.p.dJft'orte 0_8
Width 5 ft.
Total depth 45.5-11.6 ft. Eff. absorption area 800 ft'
Date of adequacy test 3/10/2006
System type SHALLOW TRENCH
Gravel below pipe 2 ft.
Monitoring tube YES Depression over field NO
Results (Pass/Fall) PASS
Fluid depth in absorption field before test"'9 in
Elapsed Time: 132 min.
Water added 823 gal
Final fluid depth 15 In. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (Y/N & type)
**TESTED THE NORTH WEST TRENCH
For 4 bedrooms
New depth 21 in.
600+ g p d
NONE KNOWN If yes, give date —
1
D. LIFT STATION
Date installed Size in gallons Manhole/
"Pump on" level at in. "Pump off
Cycles tested Meets alarm & circuit requirements?
High water alarm level at
In.
Datu
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO: PUBLIC WATER
Septic tank/lift station on lot On adjacent lots
Absorption field on lot
Public sewer main Public sewer manhole/deanout
Sewer /septic service lin - Holding tank
Ani , : - inment areas Manure/animal excrete storage areas
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation
5'+ Property line 5'+ Absorption field 51+
Water main
10'+ Water service line 10'+ Surface water 1001+
On adjace
Wells on adjacent Tots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+ Water main
101+ Surface water 100'+
Wells on adjacent Tots 200'+
Water service line
Curtain drain NONE KNOWN
F. COMMENTS
10'+
Driveway, parking/vehicle storage
10'+
G. ENGINEER'S CERTIFICATION
I certify that 1 have determined through field inspections and
review of Municipal records that the above systems am in
conformance with MOA COSA guidelines in effect on this
date.
Engineer's Printed Name
Date r f• lot*
JEFFREY A. GARNESS
•
y A. t. nsas;
CE -7953
0feeip
COSA Fee
Date of Payment 3 4,
Jib
Receipt Number
(Rev. 11/05)
5( 946'
Waiver Fee $
Date of Payment
Receipt Number
03/16/2006 11:37 9073449821
03/13/2006 16:06 907344982/
JRs Pumping
PO Bnx 773115
Bath Rinr,AK 99577
OfRa:
(907) 694.6131
Fat (907) 344.9121
F iItingJnforntsport 1
Gamest Engineering Group
3701 E Tudor Road
Suite 101
Anchorage, AK 99507
(807) 337-8179
Meagan & Chris
JRS SEPTIC
JRS SEPTIC
Jak, DoeoN6an' 1250g
P 0 Number
Tis Net 30
a.nrp: Nlkole
Mao Book
blob site Information I Cross Sten' Voyles Blvd
Remy. Robert Evans, home owner Job Comrwe. Fast seNiCe 10/13/04
21241 Paula Suo Circle
CnuOtak, AK 99587
(907) 337.8179
Additional Location Comments dro•r+: Jvlara'n.trg
Uo:1t tan house wf 0.
4bdrrn sepse in back - go to lett
when facing rause.
Front of tank le under deck. short
board allows YCcess.
Service Type
Contractor Job
City Price Each
1 8115.00
1n2s AfrA3,r.
9 Calm 6••C.
LinnetD Coen '}-e
Tax?
No
NomTw.ble TMS
Cairn! Charger. 3115.00
Atha! Chortles:
PAGE 02
PAGE 02
Service Agreement
Number: 019352
Order Date: 13 -Mar -2008
Sentra Date: 14 -Mar -2008 12:0
Technician: Tony & Steve
Tee %: 0
Jeb Typ.' Repeat
Map Ord: 21
1250g
Cations Planned: 1250
Gal. Actual'
resale Total
30.00
Hose Length: 1.5
Double Tani: ❑
Pumo System'
Baffles Inlet 0
Baffles Outlet 0
Extension alktual
8115. //S.=
Tax Total Mend Tots
30.00 3115 00
Cato net .ISI PIP* Waw and eendtlene PMtea
Signature and TON d Cuelor r R
TMs la p eINCIM3 AGREEMENT.
Accs9Nd by JR* Dete Accepted
Fee yes ease eem,wre. w Beset Amaral Gmrrn. ()cos. VS. and Mem& Care Par.nenla OW. P. plane
Aar 30 Da). a tooni. a ba meadow be toilette's. 325.00 Fee NSF Cheeks Returned.
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water and Wastewater Program
• .4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
Parcel I.D. 051.793.25
1.
FOR A SINGLE FAMILY DWELLING
SiAgb
HAA# j//a naGSG-o
Expiration Date: /0- 3 / - v :3
GENERAL INFORMATION
Complete legal description GLENN VW. ESTATES WEST PH 2. BLOCK 2. LOT 4
Location (site address or directions) NHN PAULA SUE CIR.. CHUGIAK, AK 99567
Current Property owner(s) MM&M CONTRACTING, INC
Mailing address
Lending agency
Mailing address
Real Estate Agent
Mailing Address
Unless otherwise requested, HAA will be held by DSD for pickup.
PO BOX 670495, CHUGIAK, AK 99567
2. NUMBER OF BEDROOMS:
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class Well
Public Water System
4
Day phone 688-1236
Day phone
Day phone
TYPE OF WASTEWATER DISPOSAL:
❑ Individual On-site
❑ Individual Holding tank
❑ Community On-site
Public Sewer
The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional
civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the
transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal
and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health
Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well
and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a
period of up to one year with valid water samples.) Certificates are valid for one year for properties served by
Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or
omissions in the professional engineer s work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation, based on procedures outlined in the Health Authority Approval Guidelines for this
application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional
and adequate for the number of bedrooms and type of structure indicated herein. I further verify that
based on the information obtained from the Municipality of Anchorage files and from my investigation and
inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all
applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation.
Name of Firm KND Engineering, INC
Address 20441 Ptarmigan Blvd. Eagle River, AK. 99577
Engineer s Printed Name KENNETH M. DUFFUS
Phone 696-6111
Date 10/30/02
O> :a
.. __ ..I.... ..•
•
5. DSD SIGNATURE I c+s. r W�''
t- Approved for bedrooms. O��sc•
c::1 ago
cr"'
Disapproved. a�vti(i`� m00 -us
Conditional approval for bedrooms, with the following stipulations:
By:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
(Rev. 12X0)
X
• • ON -SI I E : 'e
WATER AND • m
WASTEWATER
o- PROGRAM'
FNS JSENA j 11)
Maintenance Agreements
Supplemental Engineer s Report
Other
Original Certificate Date: / 0 - 3/-0-2.
Municipality of Anchorage
Development Services Department
Building Safety Division
On -Site Water & Wastewater Program
4700 South BMW St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Glenn View West Estates Phase 2. Block 2. Lot 4 Parcel ID: 051.793.25
A. WELL DATA
Well type PUBIJC If A, B, or C provide PWSID # _ Well Log (YM)
Date completed Sanitary seal (YM) Wires properly protected (YM)
Total depth ft. Cased to ft. Casing height (above ground)
FROM WELL LOG AT INSPECTION
Date of test
Static water level ft. ft.
Well production g.p.m g.p.m.
WATER SAMPLE RESULTS:
Col form colonies/100 ml. Nitrate mg.A. Other bacteria colonies/100 mt.
Arsenic: mg./I. Date of sample:_ Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material seotic 1 steel Date installed 11128101
Tank size 1250 gat. Number of Compartments L Cteanouts (YM) f
Foundation cleanout (WN) Depression over tank (YM) &High water alarm (YIN) f
Date of pumping NA - New Tank Pumper
C. ABSORPTION FIELD DATA
Date installed 11/28101 Soil rating (g.p.dJft2 or ft2Ax1r)1Q.§ System type Trench
Length 112 ft. Width �_ ft. Gravel below pipe j ft.
Total depth 41 ft. Eff. absorption area J00 ft' Monitoring tube I Depression over field )y
Date of adequacy test NA - New System Results (Pass/Fail) For _ bedrooms
Fluid depth in absorption field before test _in. Water added _ gal. New depth _ in.
Elapsed Time: _min. Final fluid depth in Absorption rate >= g.p.d.
Arty rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date
0. LIFT STATION
Date installed NA Size in gallons Manhole/Access (Y/N)
Pump on level at _in. Pump off level at _ in.High water alarm level at in.
Datum Cycles tested Meets alarm & circuit requirements?
E. SEPARATION DISTANCES
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot
Absorption field on lot
Public sewer main
On adjacent lots
On adjacent lots
Public sewer manhole/cleanout
Sewer /septic service line Holding tank
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation 5'+ Property line S_+ Absorption field 5'+
Water main 101+ Water service line 10'+ Surface water 100'+
Wells on adjacent Tots 200'+
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Property line 10'+ Building foundation 10'+
Water Service line 101+ Surface water 1001+
Curtain drain 50'+ Wells on adjacent lots 200'+
F. COMMENTS •
G. ENGINEER S CERTIFICATION
I certify that I have determined through field inspections and
review of Municipal records that the above systems am in
conformance with MOA HAA guidelines in effect on this date.
Engineer s Printed Name Kenneth M. Duties
Date 10131102
HAA Fee $375.00 + Rush Fee $150.00
Date of Payment 10/31/02
Receipt Number 27(400
(Rev. 12/01)
Water main 101+
Driveway, parking/vehicle storage 20'+
Jr% OF 44. 11
• `± * /_
F.
Waiver Fee $
Date of Payment
Receipt Number
471.44
,, ` is; IKerterFi, r.�. �.
frit§
; 94•14 P
tizo
ft.
II PAPOFESSO"
Y
.'.. `•`ANY..-•
' A'.. (♦
or t i ,.•
P:en. s' 1r..;:T-‘+.'y •
: r'. $. .». I. .•os.. .a..y . • ,.
�1:. •t'-' '- v
•
N
.•
- . :_.•-+
AS -BUILT.. -+
1 hereby certify that 1 have Surveyed the following described
G1.•
, n.✓ s -c. E:1+.t.41 :ubc'No, 2
Set` 'e' tf;TIr rR7,V+3Mr. -
Anchorage Recording Precinct, Alaska, and that the improve- r
ments situated thereon are within the property lines and do not '
. overlap or encroach on the property lym& adjacent thereto, that
. no improvements on property lying adjacent thereto encroach
on the premises In question and that .there. are ,no roadways,:
transmission lines or other visible easements on said property. •
except es indicated hereon.:. .: '
-- -Dated at Eagle River,'Aliski-. ' 1 -•
this 3 I-- d.y of tT`/^ e . 2001 -
•
ROBERT C. JOHNSON )4 Co.'4, •
SCALE: - Registered Land Surveyor Not -840 -I 5
N-
O 'Box 77-0456, Eagle. River, Alaska y577
Phone (907) 694-2543 ., '