Loading...
HomeMy WebLinkAboutMARIE ESTATES LT 11AMc r'i¢ Lot 11A #051-111-55 PermZt Number:. SW020234 Name: AL KUKULA 20414 STEPHEN CIR. * CHUGIAK. AK 99567 (907) 688-2284 LEGAL DESCRIPTION - 1 lA MARIE Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program. 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 ' www.ci.anchorage.ak.us (907) 343-7904 On-Site Wastewater Disposal System and/or Well Inspection Report PID Number:. 051 --111 --66 WELL: · New D Upgrade PRIVATE 255 ,. 252.02 M-W DRILUNG 7/,31/02 141 ,3-4 ~'"1 UNKNOWN ~ 1.5+ SEPARATION DISTANCES 1~ 10 $epUc Ab.orptlon Uft Well 100'+ 100'+ Sudace Water 100'+ 100'+ -- Wastewater System: I New Page I of 3 I-1 Upgrade ABSORPTION FIELD ri Deep Trench / Shallow Trench ri Bed ri Mound ri Other 0.6 ~,,~ ~ 6 (U~) SEE DWG SEE DWG ~ 5 ~ 823 (397/426) m. ~ OWNER 1.5/3.54 62/46 3034/ F-810 7~9-9/22/2002 TANK ri Holding ri S.T.~.P. Holding PubS¢~ ~=.uf~-t~c C~ ~ ~ 'rcnk s,,,~ u,-- ANCHORAGE TANK 1250 Lot Une 5'+ 10'+ - -- Foundation 5'+ 10'+ - Cu~ain Omln NONE KNOWq I Remarks: 25'+ *INSULATED THE NORTH HALF OF THE TRENCH STEEL LIFT STATION BENCH MARK TOP OF CONCRETE SLAB AT BACK CLOSEST TO HOUSE WITH 2 INCH BLUE BOARD INSULATION. DOOR OF' HOUSE Inspections performed by: AKWWC, INC. Dates: 1st 7/19/2002 2nd 9/21/2002 3rd 9/22/2002 Development Services Department Approval (~. ,~o,)R~viewed and approved by:~ Dat;'e: IIll~'~ O~ R=u~.u. DER: AS BUILT DRAWING R~C~...~ SW0202~4 ~ 051-111-66 A B ST1 23.29 59.44 ST2 31.28 62.56 DBL1 35.89 63.68 DBL2 34.83 64.22 FS 33.74 57.79 C01 19.92 48.65 MT1 20.95 48.75 C02 51.85 19.99~ST~,m .~,.,,,.,,~. (4~--'""-~ / I UT2 51.01 20.5S ~ 1'7 ~'.. , , ~ ~2 I I co~ ~.~, ~.,~ Ir,~o//. ~ ~ , , ~ ~ B I I ~ ~.,~ ~.~ ,/I /~/;;~ '~'~ REQUIRE mE ~E OF~ ~ ~N ~ ~ t , 10/1/2002 DRAWN BY: Z.T.G. 1" = 40' PAGE N U MI3E. R: 20F5 ALASKA WATER & WASTEWATER CONSULTANTS, INC. PREPARED FOR: PHONE NUMBER: AL KUKULA 688-2284 MARIE ESTATES SUBDIVISION; LOT 11 AS-BUILT DRAWING OF SEPTIC SYSTEM UPGRADE ~"~NU~': AS BUILT DRAWING SW020234 - 051-111--66 ST1 TOP OF TANK AT~ INLET - 98.49 ~ INVERT OF BUNG J AT INLET -- 97.97 L) FINAL GRADE - ~--TOP OF' TANK AT .~ OU~ m 98.51 NEW 1250 GALLON ~, SEPTIC TANK ~_iNV[RT OF BUNG AT OU~ET - 97.67 ........ ,... . . _ . ... ..._ .......... . .,., WEST TRENCH :-!~': i EAST lO' I TRENCH ALASIC'k WATER & ~STEXVATER CONSULTANTS, INC. PREPARED FOR: PHONE NUMB[R: AL KUKULA (907) 688-2284 !.[GAL DESCRiPTiON: MARIE ESTATES SUBDIVISION; LOT 11 ~fPE OF WORK: PROFILE AS-BUILT OF' SEPTIC 10/17/2002 DRAWN BY: Z.T.O. $C, AL~ PAGE NUMBER: 50F3 t %40~ %~:~4p ~%an Kuk~a 907 E88-~83 p.! M-W Drilling, 'mc. eP.O. Box l10378+Anchoroge. AK 99511+ +907-345-4000 · 907-34§-3287 Fax, Job No.: 02-149 l%jt. ct No.: Permit No. SW020234 Groundwater Well As-Built · Lq~! D~crtpaem Kukla, Al & gharou Marf~ Estat,~, Lot l ! A 20518 Stephen Cin:tc. Chugiak, AK Dom~tic Cou~truction · HeltD,9~I&: 25~' ·Cmlng$1ze: 6" ,. eCas~dTo: 252.02' eMater.tM: · DHII Metkod: Air Rotary Perf. · Well Cortgff~lon-'" 'Olin tnd X .' Screen .... Perforated ~ Method: * &:;¢zr,/ Perfor~tion dacrJlnlon: Non'e'" ,* Grout Nott~: (I) $ack- No. 8 be~loai~ granules · Notes: A 53 Steel Welt De,nqOlm~nt: Method: Air su:g~ ~ y~d I~ ~ ~ gettont ~r ~t~ (GPM~ t ~i*m ~ ~ (C~ for e M~hod: A~ li~ e Dart efcemptoton: Depth In fe~t from top of eaah~g. 0 TO 3 TO 38 TO 55 TO 78 TO 173 173 TO 211 211 TO 235 235 TO 244 244 TO 255 TO TO TO TO ~ 'TO TO TO TO 31 July 2002 · Pump Install: Well LoR Delalb of formations penetrated, sJ~e of m~t~rLaL, color and hirdaels. 3 Casing stickup 38 Boulder gravel 55 Sandy clay: dry, some gravel 78 Cobbley gravel: ~andy_ ...... Boulder gravel Silty clay: sand, cobbley Sandy gravel: wet Gravelly rand: damp Water bearing, gravel MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Pn3gram 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Jul 18, 2002 Expiration Date: Jul 18, 2003 Permit Number: SW020234 Legal Description: MARIE ESTATES LT 11A Design Engineer:. 0041 AK Water & Wastewater Consultan' Owner Name: Al & Sharon Kukla Owner Address: 20414 Stephen Cir. Chugiak, AK 99567- Pamel ID: 051-111-66 Site Address: 020518 STEPHEN CIR Lot Size: 43800 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit is for the construction of:. [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not mquirad for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: t"'~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ct.a nchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 051-111-66 Permit Number Property owner(s) Mailing address (1) Mailing address (2) AL &: SHARON KUKLA 20414 STEPHEN CIRCLE * CHUGIAK. AK 99567 Day phone Zip Code Legal description (Lot, Block & Sub'd.) LOT 11.~ MARIE ESTATES SUBDIVISION Legal description (Section, Township & Range) Lot Size ~ 3/~ ~ O Acres/Sq. Ft. N,,/A Number of Bedrooms THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade 688-2284 THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool 3 Well Only ~]~ Water Storage Jacuzzi Water Softening Unit I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER &: WASTEWATER CONSULTAN3'S, INC. (Signaturc of proporty owner or authorized agont) Permit Fees: Date of Payment: ~"~--/~- Receipt N mber: Waiver Fees: Date of Payment: ~'~ Reeoipt Number: ALASKA WATER & WASTEWATER CONSULTANTS, INC. July 8, 2002 Municipality of Anchorage Development Service Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragraw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Ret': Proposed Well and Septic System Design for Lot 11, Marie Estates Subdivision To whom it may concern: The proposed 3 bedroom house will be served by a private well and septic system. Two test holes were excavated in the area of the proposed septic system. The septic system will be designed around the 30 foot radius of test hole #2. We are proposing that a 1000 gallon septic tank and a five foot wide drainfield be installed. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. 2. TRENCH DESIGN: a. Percolation Rate: 5 & 17 minutes/inch b. Proposed Application Rate: 0.6 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 450 gallons per day e. Minimum Absorption Area: 750 ft2 f. Total Depth: 6.5 feet (max.) g. Effective Depth: 3 feet h. Width: 5 feet i. Reduction Factor: 0.58 j. Minimum Length: 90 feet total length (2 ~ 45 feet) k Effective absorption area-- 776 ft2 SURFACE WATERS: There are no surface waters within I00 feet of the proposed 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akxvwc.com upgrade. 4. TOPOGRAPHY: The area for the proopsed septic system is mostly fiat; in short, there are no slope concerns. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. ~_Jellr2y , , M.S. Pres, de~ NOTE: Attached is a site plan drawing, a design drawing, two soils log, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akww¢.com .o LOT 7. BLOCK 2. 1ROLL KNOLL S/D SERVED BYA pRNATE SEWER / LOT 6, BLOCX 2, TROLL KNOLL S/D / SD~'V~O BYA TROLL KNOLL SERVED BYA b-Y~'TE M AND ALASKA WATER & WASTEWATER ,, CONSULTANTS, INC. AL KUKLA 688-2284 MARIE ESTATES SUBDIVISION; LOT 11, BLOCK 1, SITE PLAN FOR PROPOSED WELL AND SEPTIC SYSTEM LOCATION .m''" '~ '''~ .~,~. '"- ~:""~ ..................... ~ T[MPLE DRIVE I I LOT 5, BLOCK 1, LOT 10. BLOCK 1~. ! I I~alE ESTAIES S/O ~¢~o.~ ..____,,, ',.~ ~ / . --,,k._ ,,~,-- ?/ / ,/ ~,-_-~ .,~y ,; . · I I I 3 BE~M ~ I ~ /: ~1 /'~ I / './ ~ / II I Z.T.O. 1" = 100' PAG~ NUMBE~ 1 OF2 PROPOSED DRNNF'IE~D. [XCAVA~ ~0 TRENCHE~ 7~AT ARE 8.5 FEET ~ MAXIMUM BY ~ f~t.f ~IDE BY 45 tull LONG EACH (90 r~.~ TOTA~ LENGTH). ADD 2 t~[ OF' CU~I, WASHED SEWER DRNNROCIC INSTALL TR~.NCH PAJ~LLEL TO SLOPE CONTOURS. NOTE: THE CONTRACTOR SHALL HAVE THE NORTH PROPERTY UNE FLAGGED PR OR TO CONSTRUCTION. / / / / / / AIASI~ WATER & WASTEWATER .. ~ ............ ~..~ AL KUKU~ 688-2284 2 OF 2 MARIE ESTATES SUBDIVISION; LOT 11 '. " DESIGN OF PEOPOSED WELL AND SEPTIC SYSTEM '~%~ ALASKA WATER & WASTEWATER ..' ct JSOIL LOG PERCOLATION TESTI LEGAL DESCRIPTION: MARIE ESTATES SUBDMSION; LOT 1 1 PERFORMED FOR: AL KUKLA DATE: 11/2/1998 ~ I..~ ..-'_~_~,~ .......... I~fEee~t ~ ORGANICS ITEST HOLE I ..... PAGE 1 OF 2 SOIL CLASSIFICATIONS · ~Ow ~ ORG 3-- ' ~ GP ~ ML ' GM/ML ~ GM ~ CL 4-- ' ~z m~Av~ ~ GC OL I, UPPER ~ ~ 7 ~ ~ SW HH 5-- ' SP CH  SM OH 6 SC 7~ ~ ~' DEPTH TO GROUNDWATER DATE D~ ~ ~/2/1898 D~ ~/~1/~ 14-- 151 DATE 1~/4/~8 READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 1 7:25 - 6" - 2 7:55 30 4' 2' 3 7:55 - 6' - 4 8:25 30 3 3/4" 2 1/4" 5 8:25 - 6' - 6 8:55 30 3 3/4' 2 1/4' 16-- 17-- 18-- 19-- 20 SOILS LOGGED BY: COMMENTS: PERCOLATION RATE, 13,3 (MIN./INCH) PERC, HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 3.0 FT, AND 3.5 PT, ~ FOUR HOUR PRESOAK WAS PERFORMED: ~YES D NO JODYMAUS PERCOLATION TEST PERFORHED BY: JODY MAUS PERFORMED BY AKWWC, INC. I, JEFFREY ~. GARNESS, CERTIFY THAT THIS ViIAS i°ERFORMED WITH ALL STATE AND MUNICIPAL GUIDEUNES IN EFFECT ON THIS DATE: IN ACCORDANCE ALASI~ WATER & WASTEWATER CONSULTANTS, INC. ISOIL LOOt:'- PERCOLATION TEST& II[GAL DESCRIPTION: MARIE ESTATES SUBDM$1ON; LOT 11 PERFORMED FOR: AL KUKLA DATI[: 11/2/1998 ~F~ ~ ITEST HO[[ ~1 1- PAGE 2 OF 2 SOIL CLASSIFICATIONS ~ GW ~ ORG I) ~GP ,l-- O LU GC SW ,~,~ ML CL OL ,SEE PAG SM OH I OF2 7-- ?~ DEPTH TO GROUNDWATER DATE 8-- 7 __J 14- is- (/) 2O DATE READING 11/4/1998 1 I 2 CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 7:24 - 6' - 7:54 30 6' O' PERCOLATION RATE 120+ (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) IN ACCORDANCE TEST RUN BETWEEN 6.0 FT. AND 6.5 FT. A FOUR HOURPRESOAKWAS PERFORMED: BYES DNo JODY MAUS PERCOLATION TEST PERFORMED BY: JODY MAUS SOILS LOGGED BY: COMMENTS: PERFORMED BY AKWWC, INC. l, ,IEFFREY A. OARNESS, CERTIFY THAT THIS W/kS ~ERFORMED WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE: ALASI~,~,. WATER & WASTEWATER $~.. CONSULTANTS, INC. ,-, LEGAL DESCRImON: MARIE ESTA3~S SUaDMSlON; LOT 11 V0~"..j '~E-7953 ..."/~ DAm: ./3/~99s ,~,%~... ........... ...~,~ PERFORMED FOR: AL KUKLA I~fEeel~t ~-~ORGANICS ITEST HOLE #2l GM/ML MORE 10~ ' 11~ 12-- ~ B.OJ I. 14-- PAGE 1 OF 2 SOIL CLASSIFICATIONS ~GW ~ ORO ~ GP ~ ML %~,GM CL GC OL ° SW NH ~ SP CH  SM OH SC DEPTH TO GROUNDWATER DATE DRY 11/3/1998 DRY 11/11/199E DATE ~/4/1~98 READING CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 1 7:28 -- 6' - 2 7:58 ,30 1/2' 5 1/2' 3 7:58 - 6' - 4 8:28 30 O' 6' 5 8:28 - 6' - 6 8:58 30 O' 6' 16m 17-- 18-- 19-- 20 SOILS LOGGED BY: COMMENTS: PERCOLATIONRATE 5 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 3.0 FT. AND 3.5 FT. A FOUR HOURPRESOAK WAS PERFORMED: I YES r-]NO JOBY MAUS PERCOLATION TEST PERFORMED BY: JODY MAUS PERFORMED BY AKWWC, INC. I. JEFFREY A. C. ARNESS, CERTIFY THAT THIS ~/AS/PERFORMED WITH ALL STATE AND MUNICIPAL GUIDEUNES IN E~.CT ON THIS DATE: IN ACCORDANCE ALAsIiA~ WATER & wAST~-'~'i~:E-i~'~ ff~}" 4-. ! t~ ......~.!0~ ~ON$1JLTANT$. IN~.- .... ISmL LOG - PERCO~TION TESTI ~ D~CRI~ON: ~IE ~A~ SUBDMSlON; LOT 11 ff PERFORMED FOR: AL KUKLA ~P~- ITEST HOLE #21 1-- PAGE 2 OF 2 SOIL CLASSIFICATIONS 2-- o,J ~ Gw ~ ORG I1[11 ~ GP ~ ML ~-- O ~ GM CL OL ~ sP CH 5-- r,,.g ~j~,SMsc OH I OF2 7-- 7 DEPTH TO DATE 0 GROUNDWATER lg~ 20 SFE PAG DATE READING 11/4/1998 CLOCK NET TIME WATER LEVEL NET DROP TIME (MINUTES) READING (INCHES) 7:42 - 6" -- 8:12 ,30 4' 2' 8:12 - 6' -- 9:12 60 2 1/2" ,3 1/2" (CONFIRMATION PERCOLATION TEST) SOILS LOGGED BY: COMMENTS: PERFORMED BY AKWWC, INC. I. JEFFREY~ GARNESS, CERTIFY THATTHIS W/~S/PERFORMED WffHALLSTATEAND MUNICIPAL GUIDEUNES IN EFFECT ONTHIS DATE: PERCOLATION RATE 17 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.5 FT. AND, 7.0 FT. A FOLJ~HOURPRESOAKWAS PERFORHED: .YES J'--JNO JODY MAU$ PERCOLATION TEST PERFORHED BY: JODY MAUS IN ACCORDANCE 07/18/02 15:57 F~ 269 7508 Air and Water Quality 0O2 To: Jeff Poet From: Alan Kukla Subject: Owner installation of onsitc wastcwater disPOsal system at 20518 Stephen's Circle in Chugiak. Dear Mr. Jeff Poet; I intend tO install the Jeff Gamess designed septic - drain field onsit¢ wa.stcwater treatment system on my lot in Chugiak, at 20518 Stcphen's Circle. I understand the principals of wastewater treatment. I have viewed the viewed the ADEC CD ROM entitled Septic Tanks Interactive Training for Homeowners covering installation, Inspection, and Ma'mtenance. I have experience in installing these systems. I have experience operating a backhoe and a dozer. I can read ~hc engineering plans submitted to you by my consultant Jeff Gamess,.and I intend to install accordingly. Thank you for your~pmmpt attention: Alan Kukla (907} 688-2284