T15N R2W SEC 25 LT 82
T15N R2W ecti*on 25 Lot 82 #051 �282�26 Municipality of Anchorage - ' ` On -Site Water and Wastewater Program • (907) 343-7904 a e 1 of 1 fl�A��1 ON-SITE WASTEWATER INSPECTION REPORT 2018 Permit Number: OSP 171085 PID Number: 051-282-26 Dwelling: 0 Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑ New 0 Upgrade Name: MARK HAMM ABSORPTION FIELD jeep Trench Shallow Trench E] Bed E] Mound Address 15850 RASSMUSSON ST ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 5 JTotal 1.2 GPD/SF 9 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 4.9 Ft. Gravel depth beneath pipe • 1 Ft. Subdivision Block Lot LOT 82 Fill added above original grade 0.2 Ft. Gravel length 15 Ft. Township Range Section 15N R2W 25 Gravel width Ft. Beds: Number of Lines ' Distance between lines - Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 150 Ft 1 - Ft. Well { rQt; r ,QO — __ �/ TANK 9 Septic E]S.T.E.P. E] Holding El Other Manufacturer ANCHORAGE TANK 11500 Capacity Gal. Surface Water (fir ( Material STEEL Number of compartments 2 Lot Line # rj .� fCi`� NA Foundation -� 5 1 fU P LIFT STATION Manufacturer _ Capacity _ Gal. C Curtain Drain Remarks OLD TANK ABANDONED PER CODE Pump on level at - in. Pump off level at ' in. High water alarm at - in. TANK UPGRADE AND LEACHFIELD EXT. OLD BM USED TO MATCH OLD IR Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank 3034 Tank to 3034 drainfield Installer WHITTERS Drainfield3034 CO/MT3034 Inspector CHARLES BALZARINI BENCHMARK (Assumed elevation)99.95 ft Inspection1:' 9/6/17 9/6/17 Location and description 2nd es: 3rd 9/7/17 4th ALUMINUM CAP COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL '� .• Conditional Approval: Date %.* :s��I �s. •... .ice harl ••• � � , ,,,• ���9 , 1• Izarini : fir.. t Uj Approved � l {,(��� � Date 40 �Zti��i�&�� Inspection Report 9-1-12.doc / LEGEND * MONITOR TUBE TEST HOLE -CE 13854 ES CAR SWING TIES -PORT 5x65 RESERVEI SITE FOR 5 BR. 5 BR UPGRADE IfGo ,13 _�7_NEW 1500 GAL SEPTIC TANK. --' ~— r*- (ERsaC2noc) ~— EXISTING O'xsO'.4'EFF rDRAINFIELD '.4'ErF DR�NF|ELD. ExTEmS0N CLEANOUT EXISTING TRANSFORMER FOUNDATIO CLEAN CLEANOUT MONITOR TU CAP AT NE CORNER li NEW 1500, GAL. TANK NO GROUNDWATER TABLE 9'5117 I LEGAL DESCRIPTION: T15N R2W SEC 25 LOT 82 C&M ENGINEERING SERVICES OWNER: MARK HAMM DATE:5/10/18 REV: 11 DRAWN: CB I �_EF: 907-854-5558 SEPTIC RECORD DRAWING /984 FINISHED MONITORTUBE GRADE 98.2 CLEANOUT FILTER FAB IC - FINISHED FINISHED GRADE GRADE 4,6' GRA (ORIG. GRADE COVER 4PIPE 93.9 93.1 89.0 4"0 DISTRIBUTION B.OH 4.1'EFFECTIVE SEWER ROCK SCHEMATIC ELEVATION - SCALE: NTS NO GROUNDWATER TABLE 9'5117 I LEGAL DESCRIPTION: T15N R2W SEC 25 LOT 82 C&M ENGINEERING SERVICES OWNER: MARK HAMM DATE:5/10/18 REV: 11 DRAWN: CB I �_EF: 907-854-5558 SEPTIC RECORD DRAWING Municipality of Anchorage Development Services Department On -Site Water and Wastewater Section 4700 Elmore St. P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 Soils Log - Percolation Test (ENGINEER'S SEAQ.'-), Performed For: ,'`AP'K�QN6 ►" t�" , Date Performed: J / rVf� Legal Description: LOT V� Township, Range, Section: T 15/y b� b-/ Slope Site Plan Depth C9 (Feet) 3- WAS U J L L_/ 4- Depth to Water AVD 5- r -> - 6- 7- 7- 8- 8-9-10-11-12- b-► o� oo o 9- 10- s 4 11- o 12- 1 <-) 6 13- 13-14- 14-- 15- 15 -17- 16- 17- 18- 18- 19- 19- 20 - 20- WAS GROUND WATER A ENCOUNTERED? /vo IF YES, AT WHAT DEPTH? L Depth to Water After o s? N01VE P Monitoring? E Date: 5415, (7 Reading Date Gross Time Net Time Depth to Water Net Drop /V -/c �'oq 2 b-► o� oo o i oS_-CUIf, s 4 o 1 <-) 6 0` to PERCOLATION RATE (minutes/inch) PERC HOLE DIAMETER 1' TEST RUN BETWEEN FT AND 6 j FT �— COMMENTS PR;: �D� i� �!� (7 f�It�R i C��.� % �S 1 B�EtZ f df��l� `FO,('�•— �d� tis ��V `,'7 %� `t� Gva i71 Nle° 5 fO�.t/'/✓ i AND �rEITHAT IS TEST V��PERFORMED N ACCORDANCE WITH ALLSTATE UCIPAUlLINN EFFECT O S DATE DATE� """r` MUNICIPALITY OF ANCHORAGE ollent On-Site Water& Wastewater Program PO Box 196650 4700 Elmore Road ° A Anchorage.Alaska 99519-6650 Phone: (907)343-7904 Fax:(907)343-7997 " http://www.muni.orgionsite cpart lTlCllt ,h�M 00.PGE On-Site Wastewater Disposal System Permit Permit Number: OSP171085 Effective Date: 6/1/2017 Work Type: Septic Upgrade Expiration Date: 6/1/2018 Tax Code Number: 05128226000 Site Legal Address: T15N R2W SEC 25 LT 82 G:0753 Site Mailing Address: 15850 RASMUSSON ST, UNIT B, Eagle River Owner: HAMM MARK W & LAUREN Lot Size in Sq Ft: 108900 Design Engineer: C & M Engineering Total Bedrooms: 5 This permit is for the construction of: El Disposal Field El Septic Tank ❑ Holding Tank 0 Privy 0 Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Special Provisions: A test hole is to be completed prior to construction of the septic field to demonstrate separation to impermeable barrier and groundwater and to confirm percolation rate. Location of test hole shall be as shown on permitted site plan. Construction may proceed at your own risk before the 7-day groundwater monitoring is complete. If the results require a design change, construction of the system shall stop pending On- site review and approval of a change order. Please submit stamped and signed results of the test hole with the inspection report/record drawings. Received r ` 7 ece ed By: Date: Issued By: .L, c 0,4 aux x Date: , I O ( 7 MUNICIPALITY OF ANCHORAGE c":".) Community Development Department Phone: •! - 43-7904 Development Services Division Fa, 9 -343-7997 'A On-Site Water & Wastewater Program ti �-\ ON-SITE SEWER/WELL PERMIT APPLICATION 5AM7, Parcel I.D.05 7 " a$O1" 49,6 0[ 6 TT "I Property owner(s) M4 R K i-/4 47/c1 Day phone Mailing address 7 2 1 S/41v$5o,✓ Site address j 5 co AA-55044c.55-0 Legal description (Sub'd., Block & Lot) l 1 5A/ R?c„/ 5ICG.:2,5 Lc9 g Legal description (Township, Range & Section) Lot Size !CT, 400 Sq. Ft. Number of Bedrooms S APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (E) all that apply) Absorption Field gl Initial ❑ Single Family (SF) )J (w/wo ADU) Septic Tank © Upgrade �C Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: /Jo VE Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Si'nat - o prop- y owner or authorized agent) Permit/Rush Fees: '5(oq,- Waiver Fees: Date of Payment: rj 112111 Date of Payment: Receipt Number: OQ-- a-{d'6 Receipt Number: Permit No. O f r 1 IC)? Waiver No. Permit App_9-1-12.doc CSM ENGINEERING SERVICES Ph: 907-854-5558 Municipality of Anchorage Onsite Water &Wastewater Program 4700 Elmore Rd Anchorage, Ak 99507 RE: Septic System for T15N RtW Seca Lot 82 Dear Reviewer, The owner of the above referenced property wishes upgrade the 3 bedroom home to a 5 bedroom home. The existing septic system is sized for 4 bedrooms. We are requesting approval to upgrade the existing septic system to accommodate the additional bedrooms The existing leachfield is 6'x50' w/4' effective depth, and is in excellent condition with no standing water observed in the monitoring tubes. We are proposing to extend the leachfield by 15' in length and will match the original excavation depth of 9' max below original grade. The soil logs on file show excellent soils with no groundwater to a depth of 20'. A new testhole will be excavated as shown on the plan to verify the design. Results of a percolation test and 7 day groundwater monitoring will be submitted with the inspection report A new 1500 gallon tank will be installed to accommodate the upgrade. and a reserve leachfield has been sized to accommodate 5 bedrooms. Included with this letter is a permit application, drawing, and calculations. Thank you for your time in reviewing this permit request. Please do not hesitate to contact me at 907-854- 5558 or by email cgbalzarini@gmail.com with any questions or concerns. Sincerely. Charles Balzarini, PE ik NOTES: �� 6, 1.THE PROPOSED SEPTIC SYSTEM IS GREATER THAN: 100'FROM ANY PRIVATE WELLS % `'•• •:9,, 200'FROM ANY PUBLIC WELLS / I* • TM .•* , 100'FROM ANY SURFACE WATER ! ►• i/de•;:ilp ••• � 50'FROM ANY STEEP SLOPES / 10'TO ANY PROPERTY LINE OR FOUNDATION 5 TO ANY TEST HOLES / f .*y ' ' LZARINt i Gam•.• E•1 '85'4 ` LOT59 k� ` ROFES510 �- . NO SEPARATION I \����_� DISTANCE CONFLICTS ` • • ° 1 CAR ' . . .. • 7;'2-/\ PORT •; '? , •. a • •, • / . "8/\ • • . .... .. •. . Ti:\ %r! —1---/ . '4'. , , , • • s 5x65 RESERV SITE • ti, \ - FOR 5 6R. a • 3BRHOME . • .. . W/ • PROPOSED i ,•.' --- 5 BR UPGRADE ,.` PROPOSED �c a • • - •+ •-(yiIVtWAV ..• P - - _ J d- TESTHOLE TO VERIFY , :. . '_.�-. - w DESIGN t� REPLACE EXISTING 1250 GAL TANK Lu /-- -- W/NEW 1500 GAL SEPTIC TANK ABANDON W 1— OLD TANK PER MOA REQUIREMENTS co ,�r 11 TH-2(FRES C.2002) 0 'n EXISTING 6'x50',4'EFF PROPOSED 6x15',4'EFF DRAINFIELD (DRY ON 5/5/17) DRAINFIELD EXTENSION LOT 82 a NEW CLEANOUTs o EXISTING TRANSFORMER 0 1 J m LOT 81 NO SEPARATION °S; DISTANCE CONFLICTS 0 LEGEND O CLEANOUT i NO WELL OR LOT 91 • MONITOR TUBE SEPTIC 50'BLM ROAD AND UTILITY EASEMENT ® TEST HOLE 0.5% \SLOPE INDICATOR I SCALE: 1"=40' LEGAL DESCRIPTION: LOT 82 T1 5N R2W SEC 25 CBM ENGINEERING SERVICES OWNER:MARK HAMM. DATE:5/08/17 REV:0 DRAWN:CB REF: 907-854-5558 SITE PLAN C&M ENGINEERING SERVICES 907-854-5558 Septic Design Calculations Residence: LOT 82 RESIDENCE/LOT INFO number of bedrooms 5 br Water usage/bedroom 150 gpd/br Water Usage 750 gpd DRAINFIELD system type: Conventional type: shallow trench Application Rate 1.2 gpd/sqft required absorption area 625 sqft trench width (W) 5 ft gravel depth (D) 4 ft below distribution pipe Shallow trench factor 0.5 Min Required Length: 62.5 ft EXCAVATION Depth: 9 ft Cover: 2 ft min Insulation: 2" blueboard Use Length: 15 ft extension to exist 50' field Total absorption area 650 sqft Effluent Pipe: 4" ASTM 3034 Design Summary System type: Conventional Tank: 1500 gal steel or fiberglass Field 6'x15'x4' extension Calc By: CGB Date: 5/8/2017 I • c;. OF.g41+t• t ia of go ... �". t. .$0. C!,. • ••-:'.......r ♦ s . Ba .R.ni x .. ,...1,14ft..4. 1 ;%1O Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page 1 of 2 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW020026 PID Number: 051-282-26 Name_ JEFF AND JONI HORAK Wastewater System: ® New ❑ Upgrade Address: 15850 RASMASSON ST, EAGLE RIVER, AK, 99577 ABSORPTION FIELD Phone: Number of Bedrooms696-5664 4 : ❑ Deep Trench ® Shallow Trench ❑ Bed ❑ Mound ❑ Other: LEGAL DESCRIPTION Soil Rating: Total Depth from original grade: 1.2 GPD/Ft' 9' Ft. Block Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe. GOVERNMENT LOT 82 RASMUSSON SUB. 5.0' Ft. 4' Ft Township: Range: Section: Fill added above ongmal grade: Gravel Length: -1' Ft. 50' F!. Well: F1 New ❑Upgrade Gravel width: Number of lines Distance between lines: 1 6' Ft. 1 N/A Ft. Classification (Private. A B. C): Total Depth: Cased to. Total absorption area: Pipe Material: EXISTING Ft. Ft 500' Ft= ASTM 3034 F810 Driller. Date Drilled: Static Water Level. Installer: Date Installed. Ft. CCC CONSTRUCTION 518/2002 Yield: Pump Set at:Casing Height Above Ground. TANK GPM Ft. Fl. SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To Septic Absorption Lift Holding ubliclPrivate Manufacturer. Capacity: From Tank Field Station Tank Sewer Line ANCHORAGE TANK 1250 Gal. Well 207.8' 221.3' NIA N/A N/A Matenal: STEEL Number of Compartments 2 Surface Water +100' +100' NIA NIA LIFT STATION Lot Line 73' '28.1' NIA N/A V Size NIA Manufacturer Gal. Foundation 8' 16' NIA NIA Pump on' level at: 'Pump off' level at High water alarm at in in. in. Drain NIA N/A NIA NIA Pump Make & Model Electncal Inspections performed by: Curtain Remarks: BENCH MARK Location and Description: Top of NE aluminum cap property corner. Assumed Elevation: 99.95' Ft. Engineer's Stamp tl Inspections performed by: E.R.E.S Dates: 1St 51312002y�s=�qb':��7 oa Wit' f} fl 6e'i6C 7�e'F.9�Aa800000pA a3 t)ea0 0 o J'• 2nd 5/8/02 er• �^ ?C �poO Development Services Department Approval -o5 oa ooQ ca 'A '3 Louis A. 6utera r .w CE -6736 oa 0 f Reviewed and approved by: 4Date: /CU e! Permit No. SW000117 Page 2 of 2 Municipality of Anchorage DEPARTMENT OF HEALTH AND HUMAN SERVICES ENVIRONMENTAL SERVICES DIVISION P.O. Box 196650 Anchorage, Alaska 99519-6650 Telephone: 343-4744 On—Site Wastewater Disposal System and/or Well Inspection Report Legal Description: GOVERNMENT LOT 82, SEC. 25, T15N, R2W PID No.: 051-282-26 N89056'20"E 327.72' I Swing Ties NO WATER BODIES — A I B C 17.5' 19.4' — D 33.4V36.2' E 18.8F 25.9 50' RIGHT OF WAY & UTILITY RESERVATION G 64.7H 67.5 N89051'00"W 328.41' ® — TEST HOLE • — MONITOR TUBE a — SEWER CLEAN OUT ELEVATIONS � ALUM. CAP MONUMENT o — WELL (NOT TO SCALE) As�7 suKen eiEv ' 99.95 — — — EASEMENT Mn = — EXISTING LEACH FIELD ti ORIGINAL x o - DRIVEWAY LEVIXE'LB AT, I�{I 98A TANK �f 70.8 N BEDROCK 94,2 3.8 93.1 1.0 GVT \89.1 cv' M r= CQ O GYJ .-i 0 O O 1 HED SHED R150.0' I I 1 / Lot Bl 11e11 I °— R100.0' I 1 \ 0 I R150.0' 207.6' / 21.3' GRAVEL DRIVEWAY LO /1,250 0C TANK / 2—STO ..., cc) HO C\2 ° c ® W G F �\ M6 ' HIDE X 50' LONG 4' OF GRAVEL DEPTH SCALE 1"=60' O 10/25/02 0 I O Z I I Swing Ties NO WATER BODIES — A I B C 17.5' 19.4' — D 33.4V36.2' E 18.8F 25.9 50' RIGHT OF WAY & UTILITY RESERVATION G 64.7H 67.5 N89051'00"W 328.41' ® — TEST HOLE • — MONITOR TUBE a — SEWER CLEAN OUT ELEVATIONS � ALUM. CAP MONUMENT o — WELL (NOT TO SCALE) As�7 suKen eiEv ' 99.95 — — — EASEMENT Mn = — EXISTING LEACH FIELD ti ORIGINAL x o - DRIVEWAY LEVIXE'LB AT, I�{I 98A TANK �f 70.8 N BEDROCK 94,2 3.8 93.1 1.0 GVT \89.1 cv' M r= CQ O GYJ .-i 0 O O ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW020026 Legal Description: T1 5N R2W SEC 25 LT 82 Design Engineer: 0024 Eagle River Engineering Services Owner Name: Jeff & Joni Horak Owner Address: 15850 Rasmusson St. Eagle River , AK 99577 - Date Issued: Feb 15, 2002 Expiration Date: Feb 15, 2003 Parcel ID: 051-282-26 Site Address: Lot Size: 108900 SQ. FT. Total Bedrooms: ,8' Permit Bedrooms: -r 14 BE QR0CIA w F_ Y?E C144,vG� (N 05*WWS This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. /1107— SEE l—F"-V6-1N+E&R5* REVISAV PES/(GA. Dr9rE� 112elo S K$ TE/4 re R N E +.- l a' Cj; j`/ 0A/ TE SJ' NGL, E ' �. Received By: Issued By: Date: Date: 2 j,F- � � g►�o AM MUNICIPALITY OF ANCHORAGE Development Services Department (, 1� On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 996650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW020026 Legal Description: T1 5N R2W SEC 25 LT 82 Design Engineer: 0024 Eagle River Engineering Services Owner Name: Jeff & Joni Horak Owner Address: 15850 Rasmusson St. Eagle River , AK 99577 - Date Issued: Feb 15, 2002 Expiration Date: Feb 15, 2003 Parcel ID: 051-282-26 Site Address: Lot Size: 108900 SQ. FT. Total Bedrooms: ,8' Permit Bedrooms: -r 14 BE QR0CIA w F_ Y?E C144,vG� (N 05*WWS This permit is for the construction of: ❑✓ Disposal Field ❑✓ Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. /1107— SEE l—F"-V6-1N+E&R5* REVISAV PES/(GA. Dr9rE� 112elo S K$ TE/4 re R N E +.- l a' Cj; j`/ 0A/ TE SJ' NGL, E ' �. Received By: Issued By: Date: Date: 2 Municipality of Anchorage Development Services Department oehmu: Building Safety Division' On -Site Water and Wastewater Program S A E T Y 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcell.D. acS�-cG Permit Number SWOZ!%OZ6 Property owner(s) ") L�)V 4- \�(DV-► -N oy-CL-K Day phone 4qO -RaG7 Mailing address (1) Mailing address (2) �C�C'- t}�� _1 t'- /� Zip Code "! Cz S -7 7 Legal description (Lot, Block & Sub'd.) Lt_)f `6 D. Legal description (Section, Township & Range)C Lot Size ) (�`�cJ DO Acres/Sq.Ft. Number of Bedrooms J THIS APPLICATION IS FOR: Sewer Only 0 Well Only ❑ Sewer and Well ❑ Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Si owner or authorized agent) Permit Fees: Z/Z) O Waiver Fees: Date of Payment: S LJ Date of Payment: Receipt Number: —7 Receipt Number: (Rev. 12/00) Eagle River Engineering Services Louis Butera, P.E. P.O. Box 773294 Eagle River, AK 99577-3294 February 8, 2002 Jim Cross, P.E. Manager, On -Site Services Municipality of Anchorage P.O. Box 196650 Anchorage, AK 99519 Re: BLM LOT 82, T15N, R2W, SEC. 25 Narrative & Permit Application Dear Mr. Cross: (907) 694-5195 tel (907) 694-3297 fax The proposed septic system will have very limited impact on adjacent properties for the following reasons: 1. The surrounding lots are large, allowing sufficient room for septic sites. 2. Immediate neighboring septic systems are all +30' distance. 3. Reserve space is adequate, due to absorption capacity. 4. Drainage will not be affected and is not a major consideration in our design. This septic system placement will not affect the development of any other lots surrounding this unit. The original soil log was accomplished for the lot by KND Engineering. We monitored the test hole as dry in January. If the owner wishes to move the leachfield to another site on the lot a new soil log and test hole percolation test will be accomplished. If you have any questions please call our office at 694-5195. Sincerely, Louis Butera, P.E. \2002\02-001 SEPTICNARRATIVE 4 Eagle Iver Engineering Services Louis Buterl, P.E. P.O. Box 773294 (907) 694-5195 tel Eagle River, AK 99577-3294 (907) 694-3297 fax SPECIFICATIONS FOR ON-SITE SEPTIC SYSTEM — MOA CERTIFIED INSTALLER LEGAL: BLM LOT 82, T15N, R2W, SEC. 25 April 30, 2002 A. GENERAL I . The well and septic plan is for a 4 bedroom single family residence only. 2. The drawing and or site plan shall be a part of this specification. 3. All materials and workmanship shall meet the Anchorage Department of Health and State Department of Environmental Conservation requirements. 4. All soil tests are advisory to the design and are to be verified or modified in the field by the engineer. 5. All excavations and depths are advisory and are to be verified in the field by the contractor to meet Municipality of Anchorage, Department of Environmental Conservation requirements. 6. It is the responsibility of the owner to obtain all necessary permits or easements and to locate any adjacent multi -family wells. 7. The excavation is to be exactly in the area shown on the site plan, any deviation requires engineer approval. 8. Any remaining open test hole excavations shall be filled and monitor tube removed. B. SEPTIC TANK 1. Septic tank shall be an Anchorage Tank 1250 -gallon tank of MOA approved construction. C. TRENCH 1. The trench is to follow the natural land contour to maintain uniform total depth of the trench bottom. 2. The bottom of the trench shall be level, plus or minus 1.5". 3. The total depth of the trench excavation is not to exceed 9' at any point. 4. The trench gravel is to be covered with typar fabric material. 5. Soil or combination of soil and extruded board insulation to a depth of +3' or equivalent is to be placed over the leachfield. 6. The area over the trench is to be finish graded to prevent ponding of surface water runoff. 7. The septic tank and leachfield must not be closer than 100' to any existing private well, 150' to any Class "C" well, or 200 feet to any community well. RECOMMENDED LEACHFIELD DIMENSIONS: TOTAL DEPTH= 9' GRAVEL DEPTH = 4' under pipe, 2" over pipe TRENCH LENGTH= 50' TRENCH WIDTH= 5' SOIL RATING = 1.2 GPD/ft2 BEDROOM CAPACITY = 3 SEPTIC TANK = 1250 Twenty-four (24) hours notice required for all inspections. \2001 \02-001 Trench- spec.doc EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 Eagle River; Alaska 99577 (907) 694-5195 ERES Project No.: 02-001 Calculated By: LB Date: 2/8/02 Legal: BLM Lot 82 T1 5N R2W Sec.25 Single Family 4 Bedroom Dwelling Shallow Trench Subsurface Wastewater Disposal Field TEST HOLE 1 Water use at 150 gallons per bedroom = 600 gallons Percolation rate = 2 minutes per inch Wastewater application rate = 1.2 gallons per day per square foot Required absorption area = 500 square feet Trench width (W) = 5 feet Gravel depth (D) = 4 feet Required length = Shallow trench factor * Required absorption area / W Shallow trench factor =. (W + 2) / (W + 1 +2 D) Shallow trench factor = 0.50 Total Excavation Depth = 11.0 feet Required length = 50 feet OF A �(X)' 49 TH �......... . LOUIS A. BUTERA : Q 1 ' CE -6736 O QW,"ROF ESS\SNP 02-001cal drainfield 4br 12:18 PM2/8/02 Lot 01 Well °— R100.0' u0 co CQ CYD W M 71 O C\2 0 O O 7 No Conflicting Septic Systeme Lot 59 Well N89056'20"E 327.72' A / 44.0' 0 0 / N N / RESERVE AREA PROPOSED 2—STORY 5.D' HOUSE 1250 _ Tank 5' Nide, 50' Long Neighbors Well & Septic +100' ' R100.0' HE SHED \ R100.0' HED OR4VEL DRIVEWAY rNl 50' RIGHT OF WAY & UTILITY RESERVATION N89051'00"W 328.41' L C\2 O 0 O O ® - TEST HOLE • - MONITOR TUBE o - SEWER CLEAN OUT -o- - WELL — - EASEMENT NO SURFACE WATER — — — PROPOSED LEACH FIELD NO KNOWN CURTAIN DRAINS — EXISTING LEACH FIELD o - DRIVEWAY WELL SEPTIC SITE PLAN LEGAL: GOVERNMENT LOT 82, SEC. 25,T15N, R2W OWNER: JEFF & JONI HORAK CONTRACTOR: N/A JOB# 02-001 WS DATE: 4/26/02 1 SCALE 1 " = 60' EAGLE RIVER ENGINEERING SERVICES P.O. Box 773294 EAGLE RIVER, AK. 99577 (907) 694-5195 FAX: (907) 694-3297 OF q III :49TH` .......................... �LOUIS A. BUTERA , CE -6736_= 'PROF ... N ` II{\\\\\ESS\0`������ �V (l'n 6 NEERS"S 15`L) i—; ov 06Uu`7% r r Municipality of Anchorage cola. o o a000c.aee.c � DEPARTMENT OF HEALTH & HUMAN SERVICES f 825 "L" Street, Anchorage, Alaska 99502-0650 8 € o Louls A. Butera SOILS LOG — PERCOLATION TEST "(1— CE -6736 _�_w ^r' PERFORMED FOR: �t4 Joni Ho rak DATE PERFORMED: LEGAL DESCRIPTION: 4 o f �2, Township, Range, Section: TI$IV R2W I Se -c 2 j 07FT 4 SLOPE SITE PLAN 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 COMMENTS i WAS GROUND WATER r ENCOUNTERED? S IF YES. AT WH AT L O DEPTH? P iEsT f�rJL! E epth to Water Alter u,/cd fv} Iamtonng7 d ;z hate: y-'1 2 -o -z- Reading Date Gross Net Time Time Depth to Water Net Drop S6QK A I6eva C/ 3 6/;47 oo 6 � PERCOLATION FATE /• I (minu;es,inch)PERC HOLE DIAMETER TEST RUN BETWEEN 6 FT AND 7 FT PERFORMED BY: E, n' L , S , I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDEL:NES IN EFFECT ON THIS DATE. DATE. '7'—j U " r/-�!- Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage. AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D.O.~,-/- 1. GENERAL INFORMATION Complete legal description Location (site address or directions) /~- ~-~ ,~'.~-,.,,,~-~-,.,., s"~- Expiration Date: Current Property owner(s) Mailing address Lending agency Day phone Day phone Mailing address Real Estate Agent Day phone Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. NUMBER OF BEDROOMS: 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class Public Water System Well [] [] [] [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding tank [] Community On-site [] Public Sewer [] t The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well end may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipelity of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I vedfy that my investigation, based on procedures ouUined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewatar disposal system ts(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm ~"~ ,~__ Address /~,,y'~,, ~'~' .,~,,,' ~/~'.,,-~- .~,~-~,-;' Engineer's Printed Name ,J--. DSD SIGNATURE '/ Approved for ~ Disapproved. Conditional approval for Phone bedrooms. bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist Septic System Advisory . Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Odginal Certificate Date: /0 - .~ 0 ' 4-~'.~-.. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST A. WELL DATA Well type /~,,',/~ IfA, B, or C provide PWSID # Date completed 5'- .Ta -~ ~,,.~ Sanitary seal (Y/N) ~ Total depth 'a/~- ft. Cased to. ~'/'/ ff. FROM WELL LOG Date of test Static water level ,~ ft. Wall production ~ d g.p.m. WATER SAMPLE RESULTS: Coliform ~) coloniss/100 mi. Nitrate Date of sample: /d-~ f/~,-~J~,~. Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material S,-,~'~'/ Tanksize /,,,~'~ gal. Numb~ of Compartments Foundation cteanout (Y/N) ~' 'Depression over tank (Y/N) /~ Date of pumping ~e~J /~ Pumper C. ABSORPTION FIELD DATA Date installed 5"- P --~.3.. Soil rating~r ft=/bdrm)/. ,1. Length ~"~' ft. Width ~ ft. Total depth /~/ fl. Eft. absofl:)tion area ~.5'''~.~ ft= Monitoring tube Date of adequacy test ,~.,,,-~ ,f'e~'/ew~ Results (Pass/Fail) Fluid depth in absorptio~ field before test ~ in. Elapsed Time:--'-' min. Final fluid depth--- Any rejuvenation treatment (past 12 mo.) (YIN & type) Well Log (Y/N) ,J/ Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION · ,~.3 ft. 5- g.p.m. in. ~,~ _ mg./I. Other bacteria ~ colonies/100 mi. Date installed ~" -j: '"~ q- Cleanouta (Y/N) High water alarm (Y/N) ~ Water added ~-- gal, __ in. Absorption rate >= If yes, give date Systam type ,~'~'~' Gravel below pipe zv' ft. Depression over field ~ For z'T/ bedrooms New depth ~ in. d'o~ g.p.d. D. MFT STATION ~ Date installed ~ in gallons ~.~an'~ole/Access (Y/N) 'Pump on" level at~"~in. 'Pump off' I~el at~'/~. High wate~ Datum J Cycles tested MeeL~ alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot '~ ~ ;~ / Absorption field on lot ~. :3.// Public sewer main A/ I A Sewer/septic service line ~'P / On adjacent lots On adjacent lots Public sew~' manhole/cleenout Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOTTO: Building foundation .5' / Property line v-/~ · Absorption field Water main .~' ?~ Water service line '~ ~' ' Surface water Wells on adjacent lots v-/~. / SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line ,~ 8' / Water Service line Curtain drain Building foundation /~" Surface water ~' ~'~'~" Wells on adjacent lots '/'/~' ~ Water main ,~ ~4 D~iveway, parking/vehicle st3rege. F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name HAA Fee $ Dale of Payment Receipt Number (Rev. 12/00) Waiver Fee $ Date of Payment Receipt Number in.