Loading...
HomeMy WebLinkAboutNETTLETON ACRES #2 LT 8Nettleton Acres Lot 8 #0 ! 5-062- ! 2 Not Approved Municipality of Anchorage Development Services Department Bui~ing Safety Division On-Site Water and Wastewater Program. 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ct.anchorage.ak, us (907) 343.7904 Permit Number. S~/DOI'3 LEGAL DESCRIPTION Page I of ~ ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PIDNumber:. (31~- ~'~,~'" I~--- Wastewater System: ]~New [] Upgrade Well: ~ew [] Upgrade SEPARATION DISTANCES Septic Absorption Lift Holding Tank Field Station Tank ABSORPTION FIELD ~ ~,. ! , ~ . ~. TANK [~ept~c r-I Holding [] S.T.E.P. [] Other. Public/Private u, ar~ac~,~e~ BENCH MARK I". '.."' Development Services Oepa~ent Approval Reviewed and approved by: Date: N SCALE, 1' = 58 f~. 1250 t..AL HL)PE ~ TANK $-MDE ~ 70 TOTAL L[NGTY $ f'ELrT TOTAl. DEPTIt 2 f~l' EtTECTIVE ROCK DEPTH 3 FELrT COVER OVER ~ NETT/,ETON ACRES 8731 PAULA P/ACE BRADI_cY PORTER LOT 8 ISEP~TC SYSTEI~ AS BUILT DATE: OCT. ,TO, 2001 SHEET: 2/$ C, RID: 2439 PE£H[T Il SV000395 PIB # ~/5-06£-_~£ NTAOOO88.BVG 1850 gal Septic tank Standard Trench~ 5' Vlcle ?8' Long 5' Beep ~.8' Sewer rock 3' Cover NO SCALE / Monitor //-- Cleanout~ ./ J F 3' Cover SiltBarrle~'~zo Effective l~5fl gal xepfic tank NO SCALE TDBBEN SPURKLAND P.E, II ~03 ~lS~h Ave II Anchorage Ak 99501 NETTLETON ACRES ~£ LOT 8 ~751 PAULA PLACE SEPTIC SYSTEM SCHEMATIC DATE, OC~ $0, 2001 SHEET, $/J 6RXD, £439 PERt, lIT ill SH'000395 PARCEL Iff / 015-062-12 NTAOOOS$.DWG' 4 I IIEFTY DRILL ,~$40 AKULA' IRiV AN.CI-IORAGEJ ~K (907) 345.0! 3 c/ //~ /g- 3,-7 SEP- 13 200) R EIVED ._.ue.p!. HealJ_.h & Human Services ,. ~..,. ,.., 0..,.., 0~,,.,. Oq-., 0~.""' ~"" o.b,,, ,. c,,,~, 0 '"'""' ~w'"" I. I , ] . , I I I t... ,-~.'7 ~ 'i i MUNICIPALITY OF ANCHORAGE Department of Health end Human Se/vices On-Site Se/vices Program 825 L Street, Room 502 P.O. Box 196650, Anchorage, AK 99519.6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Renewal Date Issued: Sep 22, 2000 Expiration Date: Sep 22, 2001 Permit Number: SW000395 Legal Description: NP- I I LETON ACRES #2 LT 8 Design Engineer: 0007 Tobben Spurkland, PE Owner Name: Bradley Porter Owner Address: PO Box 92034 Anchorage, AK 99509- Parcel ID: 015-062-12 Site Address: 006725 PAULA PL Lot Size: 62929 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: r~ Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be In accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Issued By: Date: MUNICIPALITY OF ANCHORAGE Depa~fment of Health end Human Services On-Sire Sen4ces Program 825 L Street, Reom 502 P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-4744 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Sep 16, 1999 Expiration Date: Sep 15. 2000 Permit Number:. SW990338 Legal Description: NETTLETON ACRES #2 LT 8 Design Engineer:. 0007 Tobben Spurkland, PE Owner Name: Bradley Porter OwnerAddrass: 1001 Wildrose Court Anchoage, AK 99518- Parcel ID: 015-062-12 Site Address: 006725 PAULA PL Lot Size: 62929 SQ. FT. Total Bedrooms: 4 Peri. it Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinklng Water Regulations ( 18AAC80 ). 3. The engineer must notify DHHS at least 2 hours prior to each inspection. Provide notification by calling (907) 343-4744 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either:. A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 9950 I (907) 279-3916 Fax (907)-2'/6-6013 SEPTIC SYSTEM DESIGN LOT 8 NETTLETON ACRES #2 BRADLEY PORTER Municipality of Anchorage Department of Health and Social Services 820 1 Street Anchorage, Alaska 99501 August 12, 1999 We are submitting an application for the installation of a well and septic system for this lot. The submittal consists of three (3) draxvings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: Impervious soil at I I feet. No Ground Water. Use Standard 5 wide trench Soil Rating. From Testhole 03/20/98 <l rain/in = 1.2 gal per sq.f'dday No. of Bedrooms 4 Required Area per Bedroom: 150/1.2 = 125 sq.ft. Total area required: 125 x 4 = 500 sqft Bottom Rock At 5 feet Top Rock At 3 feet Rock Depth 2 feet Reduction factor for 5-wide .7 Total Trench Length .$00 * .7/5 = 70 ft. SYSTEM CONFIGURATION STANDARD TRENCtl TOTAL LENGTtl 70 FT TOTAL WIDTH 5 FT TOTAL DEPTtl 5 FT ROCK DEPTH 2 PT COVER 3 let SEPTIC TANK 1250 GAL The installation of this septic system will not prevent wells from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Pon,ding and/or concentration of surface runoff willnotresultfromthisinstallation. ~'0 ~.~1/ , ~tf,.l~.//~ ~&~.~ ~-d "~"-/ ~ r,e.o .e,,~.a$ %% VACANT $0 100 SCAL, VACANT xx 8 , % 150 = 100 ?T - -1 ~ D'ell 49th TO88EN SPURKLAND P.E. 203 V! 15TH. AVENUE ANCH. AK. 99501 (907) 279-$916 / 11 / Well NETIZETON ACRES //2, 6731 PAOLA PLACE BRADLEy PORTER LOT 8 13 SEPHC SYSTEM DESICN DATE: MARCH 20, 1998 SHEET: 1/3 GRID: 2439 PERMIT ii SIK98XXXX PlO ii yy NTAOOOSI. DIVG PERFORMED FOR: LEGAl. DESCRIPTION= I .DvP o~ Munlcq~ellty of Anchorage DEPARTMENT OF HEALTH & HUMAN SERVICES 825 "L" Street, Aachorage0 Alaska 99502-0650 SOILS LOG --- PERCOLATION TEST ~P~ P-T~_ 12, B~A~."/ RI I~---"'-~'TL.-r ~-o l%.'~ Township. Range. Section; ~C. Y2. I~.~ ~4 Z- SLOPE =-;,'.,';,, PEAG[~Av'~ t_ 3 ' ~'"' "",./,,= gOO..g t-,- 9- ;'.,. 1'I 12- 14 15- 16- 17- WAS GROUND WATER EACOUNTERED? I~ YES, AT WHAT 0 DEPTH? p E Oe.~th to Waler AIlerI SITE PLAN Net Depth to Net Time Water Drop 18- 19- 20- COMMENTS PERCOLATION RATE ~' I (m,nutes/,nch) PERC HOLE DIAMETER'"~'~;~ '2 TEST RUN BETWEEN FT AND ~,~ FT PERFORMED BY: '~e .~ I '~ '~ __ CERTIFY THAT THIS TEST WAS PERFORMED IN · ACCORDANCEWITHALLSTATEANDMUNIClPALGU,CELINESINEFFECTONTHISDA'% DATE; ~[~'~ ~ I~ ~ 72-008 (Rev. 4/85) Munl~lj:allly of Anchorage DEPARTMENT O~ "tEALTH & HUMAN SERVICES 825 'L" Street. A~mhorage. Alaska 99502-0650 SOILS LOG- PERCOLATION TEST PERFORMED FOR: Township, Range, Section: SLOPE SITE PLAN LEGAl. DESCRIPTION: WAS GROUND WATER ENCOUNTERED? ILl, IF YES. AT WHAT 0 D~PTH? p E 16- ---I,;Z (J --C) ' 17- 19- ~i _ ,~, -- 20- PERCOLATION RATE ~ ~ (mmuleulnch) PERC HOLE DIAMETER T~ST RUN BETWEEN / FT AND ~ FT ~rnundwat~r rnndition~ indicated DISCLAIMFR' are for the dates Past and future presence and/or depth of groundwater can not be trom t,ese ~.b~ervat,ons. PERFORMED BY; ¥'~ .. I "~ . __ CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNtCIPAL Gl.d;. ELINES IN EFFECT ON THIS DA'[ F. DATE: 4~;'/~/ /~, ~ 72-008 (Rev. 4/85) shown only. predicted m m. m m %% '% I 4-OEO£O01.I SEPTIC $)'$~E~ 1250 GAL HOPE SEPTIC TANg 5-WIOE TPEXCH 70 TOTAL LENGTX 5 FEET TOTAL DEP~ 2 FEET EFFECTIVE 3 FEET COVE~ TOBBEN SPURKLANO ~£ 205 W ISTH. AVENUE ANCO. A~ 99501 (gO7) 279-$9~6 PERMIT # SW99XXXX % % j jNETTLETON ACRES //2, 6751 PAULA PI. ACE BRADLEY PORTER PID # YY LOT 8 JSEPTIC SYSTEIW DESIGN DATE: AUG. 12, 1999 SHEET: 2/$ GRID: 2459 N[AOOOB~.DVG P£1WA~Y T£ENCH 0.0 0 0 0 ~ 1250 9ol Sept;c St~nd~rd Trench: 5' V;de 70' Long 5' Deep 2.0' Sewer rock $' Cover ND SCALE / Monitor ~.0 Ft of Septic Rock EffecfNe ND 5CALE IUBBEN SPURKLAND P,E.. ~03 W[Sth Ave Anchopoge Ak 99501 NETTLETON ACRES //2 LOT 8 I 6751 PAULA PLACE B£ADLc")' Po£r£/2 SEPTIC SYSTEM SCHEMATIC DATE, A~ ~ ~ PERt~IT # SW9900XX PARCEL /D ~/ XX NTAOOOS$.DWO