ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW020332
Tom and Rebecca Caldwell
4313 Wisconsin, #5 Anchorage, AK 99517
245-0703. Six (6)
LEGAL DESCRIPTION
Wl/2 of SWl/4 of SWl/4 of SE1/4
14N lW 20
Well: New
Private 200
Sullivan Water Wells 1 9/6/02
6 c~u ] r~, >2 F~
SEPARATION DISTANCES
Septic Absorption LiE Holding
Tank Field Station Tank
w. >100' >100' N/A N/A
21
95
s~=w.,. >100' >100' N/A N/A
~. >5' >10' N/A N/A
.,~, >5' >10' · N/A N/A
c~.~,,. None Noted
L. xlstmg Well I. illed With Concrete, Capped and
Covered with Concrete. Existing Absorption Crib
Crushed and Backfilled. 4" Insulation Over Service
line From House to Tank. Northerly Trench More
Than 35' From 25% Break in Grade.
PID Number: 050-721-31
Wastewater System: Upgrade
ABSORPTION FIELD
5' Wide Shallow Trench
1.2 ~
5
8O0
Acreage Systems
so.~u,. Anchora§e Tank
>25' Steel
Page I of 3
Inspections performed by: Mike Anderson Dates: 1" 9/8/02
2"" 9/9/02
Department of Health and Human Services approval
Reviewed and approved by: ~,~'~ ~ ~/~(./ p,*~/~ Date: I/- ~. J-O2-
Top of Concrete Footing Second Deck Support From
the North.
100.0 rL
Septic
LIFT STATION
I
BENCH MARK
Engineer's Stamp
-' w'..-" ~
%?a"-- ........ '
FI.
Fe ASTM D3034 PVC
0/8.0/02
TANK
Municipality of Anchorage
Development Services Department Page 2 of 3
Building Safety Division
On-Site Water and Wastewater Program
On-Site Wastewater Disposal System and/or Well Insp.ection Report
Not Daylight Less Than 35 From Trench~
C5 M~=~SV /~IOTE: 4" Insulation Over Llne~
. ......; .~'~;',~
S1 49.6 56.7
~ S2 57.7 68.2
~ SV 64.4 75.4
o~°~ . ~ C6 102.2 109.7
.oo ~M2 99.5 106.9
' 'M.1. 93.7 98.8
101.0
SITE PLAN
SCALE 1" = 40'
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number. SW020332
Page 3 of 3
PID No. 050-721.31
4° ulation
7.3
2° Insulation
~',0O0 ~allon
Septic Toni<
2·
fOG BACKFILL
Insulation
98.4j
95,8
/
BACKFILL
00.0
02.3
88.1 /
40' Tpench Length
Both T?enches Some Vith Exception o¢ Insulation
PROFILE AS-BUILT
Scole: 1' - 10'
FILE No.679 llx14 '02 11:13
6~NER OF LANS~-
ID:F-I~NTIEE PARTS FflX:19072579961 PAGE 5
: . · ........ *. .............. '. .... . .-',~--~,-?-"~':,-.-. .::' .7 "t'~""~
'['i[tilig 3 0g ":!;i.'" ' m
ertifie)).'.. "
: ' , 7,
": ,-.I:~DC.CO.{~·'. : . , ' : '. ' '. · · · ' ''
· WATER %]$"ElJCBi:m
8ULI~I.V~ .....
RO. moX e?~?i~,' CHU~IAI;(, ALAeKA 90Se?' '*m TELI?HONm ~ae-2?~' .. ,... · . ' .' .. · .: '
. ..: . · ... . . .. :
/ BO~G HOLE DATA : ':" : '" ". -/ · .
.. ' ." ... .' ..: DEPTH '. "' .
· ·:'ADDRESS: ..... Fe- T.. .' ' .' · ' '; "'.;"' .= ':.' . ..
· L~dXLDE~'C'~mf~O~;~}'~'~m";" Y~c'~n ' ~. ~ ' O~,~ ."*.r/'~'J~.,m .':'~'
· . . ... . . . . , . .__ :._~___.~f ..~'.:.':
.' '.',':' ..-'..~.::... ..' · '.' ' '. · ':' ' --"5 0 "'"0~1~ ./.'~n~-7.
"' '
De~:th'of*e,~' ~o~ ~' . i~.':. '~ ~'~ ~' .:' (~'*).": '.
.~.. .............. ~ ....
' :.":73'~ ~ · '
': '.... . ,: ~An I. /i~ ll'J~,7~' ' .... ' ....
b;~, ~;~; ;;,~ ~ ....... ~ .............. ...... . .
.. ..... .. .. , , . .. ,.~.~.~ .
'"hg:~fl~k ~e G " ; ' ' ' :::". :' feet..'~; .;.. '. ·~"'..." ' " ' "'"' ...... ~.'... "
' ~et~od6fTeeUng:" ~/~ ' ' ' ' '" " ' '" '
' Op~l~pe: Qo~e~end ~openhofe ....
'-Welllnta~' '. ' ' ' ' : '
Q ~c~n~: ' .' ~t~ feet Sto~pe~" , fe~t: ' ' -'.. .. · · '"
'6P~" .... ' .... :"' "~ ~" · :.. '~.r '
rforatl~ . :~ta~ fee o~ped .... .... -..~ ..- . :. :...
"
' ~th ~rd~ o" '
'- '" foot .... '" '
.Wet) ~ t on' ton ~No " '" .... -' '"" ' ' ~ ....
~ ~ .. .......... ....'....... ..... .,........:
: m e~ta:].~:"' ',.' · * · ' ' ""
, . ; ;] .....: :..-- .'." '. ..
· ' , ..... .'. ]. : ...'..'.']....::.'. ·: ..... ' "" "4.
. .
'' , ' ' .. ', '~' .," : ' ".' ': ~' ,'" ' e' : ..' . : . ·
,A~E~6N:~ It ja the re~Popslbill~ oj th~ pro~y owner to s~bmlt.n'Copy of.~e ~e~[ log to't~e pro,er aat~br[~J.UU~l~lpaflty. :,
· of ~horage: ~pa~t of Hearth & Human'Se~Ioe~ anCot.Debarment'of ~nvffonmeqtal 'C~e~kt~on,';UatSu 'Borough: :...'
De~entofEnvl~m~talCons~atlon.. : · .. . · ......... , . ..... .. · .... .: ....:...; ....
'.*'.'..,' '.-.z ;' ".~. Received Time H0v.14..10:55AM .' '.]" '" ?" .". ;": · '"'.'~'..'... ' '.' ".;.'L'?. · '" ": ":'"~ 7 '"
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519.6650
(gO7) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Sep 06, 2002
Expiration Date: Sep 06, 2003
Permit Number: SW020332 Parcel ID: 050-721-31
Legal Description: TI4N RIW SECTION 20, W1/2 OF SWll4 OF SWI/4 OF SEll4
Design Engineer: 0014 Anderson Engineering
Owner Name: thomas and rebecca caldwell
Owner Address: 4313 wisconsin st, apt 5
anchorage, AK 99517-
Site Address: 4313 Wisconsin STreet Apartment 5
Lot Size: 206700 SQ. FT.
Total Bedrooms: 6 Permit Bedrooms: 6
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well
[] Water Storage
Ail construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of,Naska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
5. The following special provisions.
;-The original well needs to be decomlssloned according to AMC Code 15.55.060. Please state what was done with
this old original well on the As-built.
-The septic system needs to be a minimum of 35 feet horizontal distance from a slope greater than 25%. Please
show this separation distance on the As-built.
Received By:
Issued By: ~
Date:
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
~llll~ '1~ P.O. Box 196650 Anchorage, AK 99519-6650
~ ~. ~11~1 ~' www.ci.anchorage.ak.us
~l~V -- (907) 343-7904
~' ' ON-SITE SEWEPJVVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Permit Number SW
Property owner(s) Thomas and Rebecca Caldwell
Mailing address (1) 4313 Wisconsin Street, Apt. 5 Anchoraqe, AK 99517
Mailing address (2)
Legal description (Lot, Block & Sub'd.) W1/2 of SWll4 of SW114 of SEl14
Legal description (Section, Township & Range)
Lot Size 5 Acres Acres/Sq. Ft.
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
Day phone 245-0701
Zip Code
Section 20, T14N, RtW
Number of Bedrooms Six (6)
[] Well Only []
[] Water Storage []
[] Jacuzzi []
I~ Water Softening Unit []
I cedify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit
Fees:
Receipt Number:
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
...ANDERSON ENGINEERING:-:::, · i:
P.O. BOX240773 :: :':: -"-.:
ANCHORAGE, AK99524':':' ~ :'' ::
522-6779 (FAX) · · . .
September 6, 2002
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Wl/2 SWl/4 SWl/4 SE1/4, S20, T14N, RIW
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:.
The owner of the subject lot intends to upgrade the septic system on the property to
accommodate a six-bedroom home. A new well will also be drilled so the required 100'
separation can be obtained. The well and septic system currently on the lot are less
than 40' apart. We are therefore requesting a permit be issued for the construction of
a new well and septic system to serve the home. The attached Site Plan and backup
documentation identify the location and configuration of the new well and septic system
and the parameters used in the design. Also identified on the plans are the existing
well location, test hole location and the locations of the existing absorption cdb on the
lot. Drainage arrows are also shown and current drainage patterns will be maintained
after construction.
The test hole placed near the location of the proposed absorption trenches indicated
fairly clean gravel with sand and varying amounts of silt. Fractured bedrock was found
throughout the material. No impervious layers were encountered. The matedal
absorbed water well with a percolation rate of 1 minute per inch in the accepting layer.
We are therefore proposing to construct a shallow absorption system with 2 - 5' wide by
40' long trenches with a 4' effective depth. The distribution piping depth will be 2'
below the surface. Total depth of the trench will be 6'. A flow splitter valve will be
placed to insure even flow to each of the trenches. The existing absorption crib on the
lot will be pumped, crushed and backfilled. The sewer service line from the house will
be insulated with 2" of direct bury insulation under the driveway to prevent freezing.
The existing well on the lot will be abandoned in accordance with ADEC requlations.
The ground surface on the lot slopes has been carved from a hillside and is as shown
on the attached Site Plan with steep slopes from south to north and are neady flat at
the homesite and near the location for the new absorption trenches.The absorption
trenches will be constructed parallel with the slope in conformance with Municipal
requirements. Some slope flattening may be required to the north of the new trenches
to provide proper separation. Ail components of the new septic system will be
Wl/2 SWl/4 SWll4 SEll4 Section 20
September 6, 2002
Page Two
constructed a minimum of 100' from the new well to be constructed on the lot. The
system will also be constructed a minimum of 100' from any surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
to
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
o
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
~tion
D~pth~ ~
Valve~X~SC ~tion
00 ~
ic Tank
Exist
NOTE: insulation Requi]
Over Li~e Under Drive Wa'
SCOPE OF WORK:
· Proposed
well
N
1. Pump, Crush and Backfill Existing Absorption Crib. ' "~'
2. Abandon Exlsting Well in Accordance With ADEC Requirements.
3. Intersect Existing Sewer Service Line.
4. Place New 2,000 Gallon Septic Tank.
Construct 2 New40' Long x 5' Wide x 4' Effective Depth
Absorption Trenches With Bull Run Splitter ValYe.
6. Flatten Slopes to the North of New Trenches to Provide
Minimum Separation.
7. Regrade All Disturbed Areas.
8. Revegetate Area As Required.
SITE PLAN
SCALE 1" = 50'
330.0*
NOTE: No Confllcts With Wells or Septlc
Systems on Neighboring Lots.
· ANDERSON ENGINEERING
P.O, Box 240773
ANCHORAGE, AK 99524
(907) 522-7773
Cell (907) 441-4000
............ ;.-..~ .............. ' .....-.l ........... ~.~. i ~ ; ~ ~ , : I ~ ~ .
I ~ Dr~ve Way
....... % . ~ .... I ,
.... '-'"'-~"~
..... · ; . · , , ~ ~ x, , , . .. ' -
Wll2 OF SWll4 OF SWll4 OF SEll4 OF
SECTION 20, T14N, R1W
DESIGN FACTORS:
6 Bedroom House
Perc. Rate: I MinJInch
Application Rate: 1.2 GPDISF
SYSTEM REQUIREMENTS:
5' Wide Trench System
2,000-Gallon Septic Tank
4' Drain Field Rock
6 Bedrooms X 150 GPDII.2 GPDISF (Application Rate) = 750 SF of Absorption Area
750 SFI5 LF (Width)* .5(Red. Factor) = 75 LF Trench Length
Therefore: Construct Two 5' Wide Absorption Trenches Each 40' in Length For a Total
Length of 80'. Flow Line Elevation in Trench to be 2' Below Original Ground Surface.
Total Depth to be 6' Below Existing Ground. A Zabel or Bull Run Flow Splitter Valve Must
Be Placed to Assure Even Effluent Flow to Each Trench. Maintain 10' of Separation
Between Each Trench. Provide 3' of Cover or Place 2" Insulation and 2" of Cover Over
Trenches. 4' of Cover Required Over Septic Tank.
4~0~
Natural
Backfill
'5'0"
· I I
C~otextile
Fabric
4" Perforated
PVC (ASTM 3034)
Drainfield
Rock
NOTE:
TYPICAL WIDE TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' From Wells in the Area.
Minimum 10' Separation From Water Service Line.
Municipality of Anchorage
Building Safety Division/On-Site Water and Wastewater Program
4700 South Bragaw Street, Anchorage, AK 99519
SOILS LOG - PERCOLATION TEST
Performed For: Tom Caldwell
Legal Description: W1/2 SWl/4 SWll4 SEl/4 Section 20 T14N R1W
SLOPE
OG/OL
·
TESTHOLE NO. 1
Date Performed:
SITE PLAN
See Site Plan
5
6
7
8
9
10
11
Gravel
with
Sand
Silt and
Fractured
Bedrock
Was Groundwater
Encountered? No
If Yes, What Depth?
Depth to Water
After Monitoring None
Da[e: 9/4/02
S
E
12
13
14
15
16
Bottom of
Hole
Reading Date Gross Net Depth To Net
Time Time Water Drop
I 29-Aug 1:13 1.25
2 1:23 10 Dry 10
3 1:24 1.25
4 1:34 10 Dry 10
5 1:35 1.25
6 1:45 10 Dry 10
17
18
21
Perc. Rate: 1 Min.llnch Perc. Hole Diameter: 6"
Test Run Between 4.5 Ft. and 5.5 Ft.
Comments: Perc Cavity Presoaked Prior to Test.
Performed By: MEA. I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 91410;2
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: Wll2 SWll4 SWl/4 SEll4 SECTION 20 T14N RIW
GENERAL:
The scope of this project includes the procurement and placement of a
new 2,000-gallon septic tank at the location shown on the site plan
and the construction of 2 new 40' long by 5' wide by 4' effective depth
absorption trenches also shown on the Site Plan. The total depth of
the trenches will be 6' below existing ground and the distribution pipe
will be placed at 2' below the surface. A flow splitter valve will be
required to assure even flow to each trench. 2" of Insulation must be
placed over the service line and under the ddveway from the tank to
the absorption trenches. Ail components of the septic tank and
absorption trenches must be constructed a minimum of 100' from the
proposed well on the lot. A minimum of 4' of fill must be placed atop
the septic tank and 3' of fill above the absorption trenches. In lieu of fill
2" of direct bury insulation may be placed with 2' of fill atop the
insulation. The existing absorption crib on the lot must be pumped,
crushed and backfilled. In addition, some slope flattening may be
required to assure proper separation distance from the new absorption
trenches.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and veril~cation of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
pdor approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. The 2,000-gallon septic tank must be procured from an approved
septic tank manufacturer and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
· W112 SWll4 SWl/4 SEll4 Section 20
September 6,' 2002
Page 2 of 2
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
budal insulation.
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3, A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill,
4. Monitor tube~ must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
o
Contractor shall vedfy the septic tank and drainfield are a minimum
100' away from any pdvate water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
6. Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic.
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H,D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
'Wll2 SWll4 SWl/4 SEll4 Section 20
September 6, 2002
Page 3 of 3
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
5. A permeable geotexfile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
.~k~as~ CT&E Environmental Services Inc.
CT&E Rtl.#
Client Name
ProJect
Client Sample ID
blatrh
PWSID
Sample Rerr~k~
1027892001
Anderson Eng~cering
MP 4.2 Hiland Rd'~ ~ ~ er' ,5'bJ I]¥ OrSuOq'~ O0
~ 4.2 Hiland Rd/-- ,,
0
All Dates/Times are Alaska Standard Time
Printed Date, rflme 11/19/2002 15:04
Collected DatWTime 11/15/2002 14:30
Recelved Date/Time 11/15/2002 15:20
Tecbnlcal Director · Stephen C. Ede
Released B~v~~ ~
R,~ult~ PQL UniLs MetJ~d
Allowable Prep Analysi~
Limits Date Date Init
Nat:ers Depar t:menl:
Ni~xate-N
1.29 0.600 mg/L EPA 300.0 f<-lO') 11115/02
JS _
Microbiolo!;ly Laboratory
Total Colifon~
col/lOOmL SMI8 9222B
(<-I) 11/15/02 KAP
Received Time Nov.19. 5:04PM
CT&E Environmental Services Inc.
Laboratory Division.
" 2('0 Wo Potter Drive
Drinking Water Analysis R¢?ort for Total Col}form Rneteria'. A~eho,age. ^K SSs~ S-~ 60S '
--w ...... Tel: (907} 562-2343
~ INSTRUCTIONS ON REV_FJ~SE SIDE ~E]:ORJE COLLECTING S/IMP£E Fax: (907) 661-5301
: MUST BE COMPLETED BY WATER SUPPLIER
El PUBLIC WATER SYSTEM I.D- # IIIII
Q PRIYATE WATER S. YSTEM
0 SenttRe~uits 0 SendInvolce
Month .Day Year
,IRP LE TYPE:
outine . .,,re Treated Water
Repeat Sample (for routine sample
Untreated
Water
· with lab ref. no. · )
Special Purpose
Time Collected
SA~,~PLE LOCATION. Collected BY
TO DE COMPLETED BY LABORATORY
Analy~$ shows this. Water SAMPLE to be:
~/ ~atis factoty '
O Unsatisfactory
[1 Sampli over BO hours old, results may '
· be unreliable
Sample too 'long in transit; sample should
not be owr~hours old at examination
to indicate reliable results. Please send
new sample.via special delive~ mail.
Date Received'
Time Received i
^naiy,is
Analytical Method: ~'~Memb~anc Filter · t:l IVEVIO-MUG
* Number of colonies/100 mi.
Lab Ret'. No. Result* Analyst
Sent to A.D.}LC. Anch ~ks Jun U
Fax~
Date: Time:
~ient notified of unsatlsfacto~ resul{s:
Phoned Spoke with Faxed
Date: Time:
'F/YMt ~_ I ~JI BACTERIOLOGICAL WATER ANALYSIS RECORD
MMO-MUG Result: Total C~llform E. Cell
Membrane Filter: Direct Comtt ( ) __ Colonies/100 mi
v
Verification: LTB EGB COLIFIRM
Fecal Coliform Confirmation
Final Membrane Filter R~sults
Coliform/100 mi
..... Received /ime_','t0v.19.~ 5:04P~°fthesosGr°up(s°clat6GaneraledesmvelRance)
ENVIRONMENTAL FACILITIES IN ALASI~A. /'~ -~-~,a. SLORIDA. ILLINOIS. MARYLAND. MICHIGAN. MISSOURI. NEW JERSEY. OHIO. WEST VIRGINIA '
Municipality of Anchorage
Development Sep.,ices Depzrtment
Building Safely Division
On-Site Waler and Wastewaler ProGram
4?00 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
wvc, v.ci.anchora ge.ak.us
(907) 343-7904
O
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 050-721-31
1. GENERAL INFORMATION
Complete legal description
Expiration Date:
W112 of SWll4 of SWII4 of SEll4 Section 20 T14N R1W
Location (site address or directions) 6?;6 Hiland Road
Current Property owner(s) Tom and Rebecca Caldwe!l Day phone 245-0701
Mailing address 4313 ~,qsconsln St.. Apt. t~o. 5 An.._choraqe. AK 9951
Lending agency
Day phone
Mailing address
Real Estate Agent
Mailing Address
Day phone
Unless otherwise requested, HAA will be held by DSD for pickup.
2. NUMBER OF BEDROOMS:
six (6)
3. TYPE OF WATER SUPPLY:
Individual Well []
Individual Water Storage []
Community Class__ Well []
Public Water System []
TYPE OF WASTEWATER DISPOSAL:
Individual On-site []
Individual Holding tank []
Community On-site []
Public Sewer []
The Municipality of Anchorage Development Services Depadment (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in pe:aGraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of
title (except be[v,,een spouses) for propedies seA, ed by a single tamiIy on-site wastewater disposal and/or water
supply system. DSD also issues HAAs upon request to hcmeowners. Ce.lificatos of Hea~th Authority Approval are,
valid for 90 days from the date of issue for prcparties sat.,ed by a private cr Class C ,.ve~l and may be reissued wi!h
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year wilh
valid water samples.) Certificates are ~/alid for one year for properties served by Class A or B wells or a public
water system. The Municipality of Anchora.ce is not responsible for errors or omissions in the professional
engineer's work.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the
on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I further vcrify that based on the information obtained from the
Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances,
and regulations in effect at the time of insta!lation.
Name or Firm Anderson Enqineerinq
Address P.O. Box 240773 Anchoraqe, AK 99524
Engineer's Printed Name I'Jichael E. Anderson. P.E.
Phone 522-7773
Date '1f117102
DSD SIGNATURE
L/''''/ Approved for
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Well Flow Advisory
X
Maintenance Agreements
Supplemental Engineer's Report
Other
'
Original Certificate Date: //- :~. ! - O ~
Legal Desc~ption:
WELL DATA
Well type Private
Date completed IF6/2002
Total depth .200 lt.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 995196650
www.ci.anchorage.ak.us
(9O7) 343-79O4
HEALTH AUTHORITY APPROVAL CHECKLIST
W1/2 of SW1/4 of SW1/4 of $E114 Section 20 T~I4N RIW
IfA, B, ~rC provide PVVSID #
Sanitary (Y N) Y_
C,~sed !o ~1
F~OM WELL LOG
Par(e{ ID: 050-721-$1
Date of test
Static wate~ leveJ
Well production 6
WATER SAMPLE RESULTS:
' Cottfo~m 0 colonies/100 mi.
Date of sample: 11/15/2002
B. SEPTIC/HOLDING TANK DATA
Tank Type/Mate~al. 8eDtl~/Stset
Tank size 4000 , gal.
Foundation cleanout (Y/N) Y_
Dale o~' pumping
C. ABSORPTION FIELD DATA
Date installed 9B/2002
Length 80
Total depth 8_ ft.
9/6/2OO2
95
Nil~ta 1.07 moji.
Collected by: MF~
Well Log (Y/N) Y
Wres properly protected (Y/N) Y
Casing heighl (above ground) >24
AT iNsPECTION
iN.
Number of Compartments _2
Depression over tank (Y/N) ~_
Pumper New Construction
Other bacteria 0 colonies/100 mi.
Date installed 9/8/2002
Ctaanouls (Y/N) Y
High water alarm (Y/N) N
Date of adequacy test Results (Pass/Fall)
Fluid depth in absorption field before test _ in. Watm' added gal.
Elapsed Time: __ min. Final fluid depth __ in. Absorption rate >=
Any rejuvenation treatment (past 12 mo.) (Y/N & type) N
Soil rating (g.p.d./it~ er ~/bdrm) t.2 GPD/SF System type 5' Wide Trench
fl. Width S fl. Gravel below pipe 4 fl.
Eft. absorption area 800 ~ Monitoring tube Y Depression over field N
Fo~ bedrooms
New depth in.
g.p.d.
If yes, give date
D. UFT STATION
Date installed
'Pump on" level at in.
Datum
E. SEPARATION DISTANCES
Size in gallons
*Pump off" level al __
Cycles tested
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot >t00'
Absorption field on lot >t00'
Public sewe~ main N/A
Sewer/septic service line >25'
in.
Manhole/Access (Y/N)
High water alarm level at
Meets alarm & circuit requirements?
On adjacent lots >t00'
On adjacent lots >100'
Public sewer manhole/cleanout N/A
Holding tank N/A
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Properly line
Water ma~n N/A Water service line
Welts on adjacent lots >100'
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Properly line >10.
Water Service line >t0.
Curtain drain None Noted
F. COMMENTS
Building foundation >t0.
Surface water >100.
Wells on adjacent lots >1.00'
Absorption field >5'
Surface water >t00'
Water main >t0.
D~veway, parking/vehicle storage >25'
G. ENGINEER'S CERTIFICATION
I cen~fy that I have determined through field inspections and
review of Municipal records that the above systems are in
conformance with MOA HAA guidelines in effect on this date.
Engineer's Printed Name Michael E. Andemon. P.E.