ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW020146
MM&M Contractin~
P.O. Box 670495 ChuRiak, AK 99567
688-1236
Three (3)
LEGAL DESCRIPTION
River View Estates
5 3.6
Well: New
Private L_Z_;._.IT° L~O F,. 21 F,.
Sullivan Water Wells
7 c,~ I F~. 2
SEPARATION DISTANCES
Septic Absorption Lift Holding
Tank Field Station Tank
w. >100' >3.00' >'100' N/A
s~.w.,.>3.00' >100' >100' N/A
~ >5' >3.0' >3.0' N/A
~o~,~ >5' >3.0' >10' N/A
None Noted
PID Number: 050-792-3.7
Wastewater System: New
ABSORPTION FIELD
5' Wide Shallow Trench
3..2 c.~ 4
3..5 ' 2 F,. 54 F,.
5 ~,. 2 I >3.0
385.7 ~' ASTM D3034 PVC
MM&M Contracting 7/3.9-24/02
TANK - STEP
Anchorage Tank :1.,250
s~,~ Ur, Steel
>25'
~' 250
42
Orenco
Garage Slab
LIFT STATION
Anchorage Tank
Three (3)
42,.. 44,..
BENCH MARK
100.0 FL
Inspections performed by: MEA Dates: Ist 7/3.9/02
2"~ 7/24/02
Department of Health and Human Services approval
Reviewed and approved byX/y ~.
N87°44'58"E 270.48
Alternate Site
TH2
16
$2
PLAN AS-BUILT
SCALE 1" = 50'
A
S1 14.3
S2 19,3
M~ 20.4
B
31.6
34,3
35.1
Municipality of Anchorage Page 3 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW020146 PID No. 050-792-17
12 Orifices In Each Lateral Each 3/16" In Diameter and 2.25' Spacing
Geotextlie Fob,'ic
l)~-oinFielct Rock
110.4
~--1' PVC
~-107.1
104.9j
NOTE: Both Trenches are Identical
PROFILE AS-BUILT
Scale: Measurements Shown
FRO~ : C~LINTRY' RERLTY ~ NO. : 9076881238 Oct. 14 2g~. E~2.: 13Ptl P5
~,~:~;~,;.~.,,~.~;,~;;~,:~-f~,~; -.~?..,, .~j-5='.~';~?~t,,,;~.~..~'.. ,. ................ ~ ~.. . . ~ .......
· .~. '~'.~z;'~:;~*~;~.~f~:~::; ~:~g'F.~' ~'?,~,,'. '" .". ' . ' '~ . ' · ' .. "'-. · ' '. ~. . ..
~"' ~ ?g':"';"~ ~1 ~"~"~;~" ~" .... ' .... ' .....
' ;/~ ~ g.:.~C~ ~ ~,;t~'A'~.~*~:~ .."' ~ ..'. ..... ~ ..... -~ .. --.~ , . ' - ~ ' · =' ' --' t . ',.- ',':
,-~.-.~- ,~1,'..~-.'-~,.' ..... - ~*..~,t. * ..,......~' , .b" .0 E~'/~ ~ .' '*'..."
..... ~:~.~ . ~,~.~ .... : ...... . . ...,:, -- ..... ........ . ..... . . . .. . .. ,..,
~i~St~ckup.~oye.G~ . ~ · . feet · , .......... · ....
· ~..~.. ;?~,{'3 t.~:k' ~;~'~>;,~: ..... '. ~', · ;.~ .:...,.. '. : · .:: .... . .
..... . . ~.~......:,~ t..: ...
~?J~'~ ~.~; ',;~::{.~:~.,;?.~'~2;.'~, ,,~,~ ~.~; t-~-; · .' .. '- · .. ~, ..... :.' " '- ...... . ". · ~ · . ' · .' ~": . .'.",..' ~"-':' ·
~ '~c-~4;~q~, ~.~ ~,~-~-;.-%--.,.~.~;:~-~-~.~=.., -. · ' ' ' ' ' ' " " '' ' ~;"" '"'"
:Me~6fDi~f~t~~;~:,...:- .~.~.~,:~,.;/ ~.;..,~, ~-: ~.fi;. ,. ,. ..... .,........,~?..,.. ,.~..- <,...:.~ ........ ~ ~.
Nov~nlx:r I~, 2002
F~# 907-6~1.123g
EI~rlcal work perfo'ar,~d (~ rcqucs~
Mlvl,~ ~ng, Inc.
P.O. Box 6?0495
CheWink, AX. 9956?
To whom it may concc~:
The eleclri~l insmllaQon of the lift s~agon
~EB ~ EL~C, LLC
cc: ~ C~*acfu~. l~c.
Hie
P.O. Box 876510, P/art/la, Al~.~ka 99(~?
Office (90~ 375.3~95 / Cel1232.868?/ Fax 375-389¢
Eeceive~ Ti~e Nov.20. 10:34AY
~/~ 'd tOl~'°~ ~ldl~:~ ~00~ '0~'^°~
MUNICIPALITY OF ANCHORAGE
Deve/oprnent Services Depar~nent
On-Site Water & Wastewater Program
4700 South Bragaw SYeet
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Jun 05, 2002
Expiration Date: Jun 05, 2003
Permit Number: SW020146
Legal Description: RIVER VIEW ESTATES BLK 5 LT 16
Design Engineer: 0014 Anderson Engineering
Owner Name: MM&M Contracting
Owner Address: PO Box 670495
Chugiak, AK 99567-0000
Parcel ID: 050-792-17
Site Address: 007401 WATERFALL DR
Lot Size: 41971 SQ. FT.
Total Bedrooms: 3 Permit Bedrooms: 3
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by caIIing
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either:. A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-7904
ON-SITE SEWER/WELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 050.792.17
Permit Number SW
Property owner(s) MM&M Contractin.q, Inc.
Mailing address (1) P.O. Box 670495 Chuqiak, AK 99567
Mailing address (2)
Day phone 688.t236
Zip Code
Legal description (Lot, Block & Sub'd.) Lot t6, Block 5, Riverview Estates Subdivision
Legal description (Section, Township & Range)
Lot Size 41,971 SF Acres/Sq. Ft. Number of Bedrooms Three
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Pool
[] Well Only []
[] Water Storage []
Jacuzzi []~
Water Softening Unit
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
Receipt Number:
(Rev. 12/00)
Waiver Fees:
Date of Payment:
Receipt Number:
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 (FAX)
May 29, 2002
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
Lot 16, Block 5, Riverview Estates Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Permit No. SW980100
Dear Onsite Services Engineer:.
A permit was issued for the construction of a well and septic system for Lot 16, Block 5,
Riverview Estates Subdivision in May of 1998. The permit subsequently expired and
the property changed hands. The current owner of the property intends to construct a
three-bedroom home on the lot. We are therefore requesting the permit be reissued for
the construction of a new well and septic system to serve the home. The attached Site
Plan and backup documentation identify the location and configuration of the new well
and septic system and the parameters used in the original design. Also identified on
the plans are the location of the well on the lot, test hole locations and the locations of
existing wells and septic systems in the area. Since the original permit was issued both
the lot to the south and to the northeast have been developed. The locations of the
wells and septic systems on these lots have been added to the drawings.
The test holes placed near the location of the proposed absorption trenches and
alternate site indicate slightly silty gravel with a percolation rate of less than 3 minutes
per inch. Groundwater was found during the placement of the test holes and was
monitored during the high water period. We are therefore proposing to place 2 - 5' wide
by 27' long by 2' effective depth absorption trenches on the property. The total depth of
the trench will be 4'. The distribution pipe will be placed at 2' below the ground surface
to provide sufficient separation from groundwater.
The ground surface on the lot slopes as shown on the attached Site Plan with moderate
slopes east to west. The new absorption trenches will be constructed In conformance
with Municipal requirements and parallel to ground contou ,rs, where possible. All
components of the new septic system will be constructed a m~n~mum of 100' from the
well on the lot and those In the area and 10' from the service line from the well to the
house.
If the system is constructed in accordance with our design the following statements
· Lot 16, Block 5, Riverview Estates
May 29, 2002
Page Two
apply:
i.
2.
3.
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattem will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
LOT 16, BLOCK 5, RIVERVIEW ESTATES
SCOPE OF WORK:
1, Place New 1,250 Gallon STEP System.
2. Construct 2- 27' Long X 5' Wlde X 2' Effective
Depth Absorption Trenches.
3. 1.25" PVC Delivery Line From Tank.
4. 1" Distribution Line In Trenches .....
5. 12.3116" Holes @ 2.25' Spaclng PerTrench
OT t5
LOT
t4
" p~OPOStO omvt~Y ~_~ PROP.
LOT I0
~ LOT 16
· xx PROP.
LOT 9
SITE PLAN
SCALE 1" = 60'
.o I
SEPTIC TANK
· .Ew ' roe I
t
#
%
L~T 7
LOT 16, BLOCK 5, RIVERVIEW ESTATES
[~ Bedrooms X 150.,GPD 11.2 GPDISF = 375 SF of Absorption Area
75 SFI5 LF 0Nidth~.7 (Red. Factor) = 52.5 LF Trench Length
DESIGN FACTORS:
Three Bedroom Home
Perc. Rate: 2.7 MinJInch
Application Rate: 1.2 GPDISF
SYSTEM REQUIREMENTS:
5' Wide Trench System
1,250 Gallon STEP System
2' Drainfield Rock
ierefo?: C_onst.ruct a 2-27' Long X 5' Wide X 2' Effective Depth
.sorpuon/rencnes. Flowline Elevation in Trench to be 2'
elow Original Ground Surface. Total Depth to be 4' Bel,ow Existing
round. Mound Over Trench to Provide a Minimum of 3 of Cover
or Provide 2" of Direct Bury Insulation and 2' of Cover.
3/16" Diameter Holes
2.25
'~0. S.T.£... 1~ DRAINFIELD DETAIL
PRESSURE DISTRIBUTION
CALCULATION
Elevation at Highest Discharge Point
Pressure at Highest Discharge Point
Liquid Level in Tank (Elevation)
Diameter of Holes in Distribution Line
Diameter of Distribution Line
Hole Spacing in Distribution Line
Length of Transport Line
Diameter of Transport Line
125'
5' Head
115'
.1875" (3116")
2.25'
65'
1.25"
Q = 12.4d~' = 12.4(.1875)(.1875)~/~- = .9748 GPM/Orifice
= .9748 * 24
= 23.4 GPM
TDH = (130-115) + .0192(23.4)(23.4)
= 15 + 10.5
I.Z~7
+ .000995(23.4) (65)
(1.25) ~' b ~
+ 7.4
= 32.9
Therefore 24 Orifices - 12 in Each Lateral @ 2.25' Spacing
ill I~:::ll~i~l ~:li·
- ~d EFFLUENT PUMP~ '~
[i l/2Hptol I/2Hp
;; SINGLE'PHASE, 60HZ
i, _~ llS/230 VOLT
~ ~ PC#2
. .
r "~l' ~ ~ig~ ' ~ '..~ '_
LA-I--. - '~-,'~'-.~ -
~'i ,: ,t'
: ~ II,I ~
, . ~. :, ,~
}: ,:,! ..
-- .~-~
- ~i"?' '~"- "~
. ..t.A-.~. ~?,~..--.
O~ENCOSYSTEMS, INC ]
!',!L2'T. D!-e-,C-HA.~GE.- GPM
[2826~OLONIAf-ROAD ROSEBURG, OR97470 (503)6T3-0165]
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 16, BLOCK 5, RIVERVlEW ESTATES SUBDIVISION
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250-gallon combination septic tank and lift station and pressure
distribution system. Work also includes the construction of 2 - 27' long
x 5' wide x 2' effective depth absorption trenches at the location shown
on the attached Site Plan. The new trench distribution piping shall be
constructed 2' below existing ground level for a total trench depth of 4'.
Direct bury insulation may be required to provide the minimum
coverage required over the new trench. In lieu of insulation 3' of cover
may be placed atop geotextile fabric over the new trenches.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations, Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK/LIFT STATION INSTALLATION
The 1,250-gallon septic tank/lift station must be constructed by
certified tank manufacturer. Construction shall include an 18" manhole
to provide access to the lift station.
2. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
3. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade,
4. Tanks installed without 4' of cover shall have a minimum of 2" of direct
burial insulation.
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drain field.
Lot 16, Block 5, Riverview Estates
May 28, 2001
Page 2 of 3
6. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAIN FIELD CONSTRUCTION:
1. The drain field shall be constructed to the dimensions shown on the
design, The bottom of the trenches shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a
level bed of drain field rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabdc must be placed between the drain field
rock and the natural soil backfill.
4, Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
Contractor shall vedfy the septic tank and drain field are a minimum
100' away from any pdvate water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trenches to drain away.
A minimum 2' of accepting soil is required below the drain field rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
The lift station must be constructed by a municipally approved septic
tank manufacturer. An Orenco 20 OSI 05 HHF-5 pump is
recommended.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid). ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Femco, or equal).
Lot 16, Block 5, Riverview Estates
May 28, 2001
Page 3 of 3
5. A permeable geotextile fabdc (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be bacldilled.
The second inspection must be conducted after the placement of the
geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
Rick Mystrom,
Mayor
Department of Health and Human Services
825 "L" Street
P.O. Box196650 Anchorage. Alaska 99519-6650
http: :www c~ anct~orage.ak.us
May ?, 1999
Brian N & Kathryn K Grandorff
19546 3rd Street
Eagle River, Alaska 99577 8421
Subject:
Lot 16 Block 5 River View Estates Subdivision
Permit # SW980100 P1D # 050-792-17
The subject permit, issued May 7, 1998 by this office for a single family well and/or on-
site wastewater system, has expired as of May 7, 1999.
A new permit must be obtained from this office for a well and/or on-site wastewater
system NOT installed by the expiration date.
If you have drilled the well, a well log must be sent to this office for documentation of the
installation and to close the permit.
If a licensed Professional Engineer has inspected the installation of the on-site wastewater
system, the original as-built inspection report must be sent to this o~ice for review,
approval and documentation. All inspection reports must be submitted within 30 days of
construction completion.
When applying for a new permit, the fees are: $320.00 for an on-site wastewater permit;
$120.00 for a well permit and $440.00 for a combined on-site wastewater and well permit.
If you have any questions, please call this office at 343-4744.
S~ncerely~'
Jamqs Cross, PE
Program Manager
On-site Services
enc: Copy of Permit
PAGE 1 OF 1
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH ~5.ND HUM3kN SERVICES
P.O. BOX 196650, 825 "L" STREET, ROOM 502
ANCHORAGE, A~LASKA 99519-6650
ON-SITE WELL AND WASTEWATER DISPOSAL SYSTEM PERMIT
PERMIT NUMBER:SW980100
DESIGN ENGINEER:S & S ENGINEERING
OWNER NAME:GR3kNDORFF BRIAN N & KATHRYN K
OWNER ADDRESS:2221 MULDOON ROAD SPACE 577
3kNCHORAGE, ALASKA 99504
DATE ISSUED: 5/07/98
EXPIRATION DATE: 5/07/99
PARCEL ID:05079217
LEGAL DESCRIPTION:
RIVER VIEW ESTATES BLK 5 LT 16
LOT SIZE: 41971 (SQ. FT.)
NUMBER OF BEDROOMS: 4 THIS PERMIT: 4
THIS PERMIT IS FOR THE CONSTRUCTION OF:
DISPOSAL FIELD /SEPTIC TANK / WELL SYSTEM
ALL CONSTRUCTION MUST BE IN ACCORD~kNCE WITH:
THE ATTACHED APPROVED DESIGN.
ALL REQUIREMENTS SPECIFIED IN ~%NCHORAGE MUNICIPAL CODE CHAPTERS
15.55 kND 15.65 AAID THE STATE OF ALASKA WASTEWATER DISPOSAL
REGULATIONS (18AAC72) kND DRINKING WATER REGULATIONS (18AAC80) .
THE ENGINEER MUST NOTIFY DHHS AT LEAST 2 HOURS
PRIOR TO EACH INSPECTION. PROVIDE NOTIFICATION BY
CALLING 343-4744 ( 24 HOURS ) (NOT REQUIRED FOR WELL ONLY PERMIT)
FROM OCTOBER 15 TO APRIL 15 A SUBSURFACE SOIL
ABSORPTION SYSTEM UNDER CONSTRUCTION DURING FREEZING
WEATHER MUST BE EITHER:
A. OPENED A/gD CLOSED ON THE SAME DAY
B. COVERED, SEALED ~kND HEATED TO PREVENT FREEZING
THE FOLLOWING SPECIAL PROVISIONS.
SPECIAL PROVISIONS
DATE:
ROBERT C. COWAN, P.E.
April 17, 1998
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
HEALTH AUTHORITY
APPROVALS
SEWER&WATER
MAIN EXTENSIONS
SEWER&WATER
INSPECTION
ENGINEERING STUDIES
A.ND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAO OESIGN
SOIL TEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ON SITE
WASTEWATER
DISPOSAL SYSTEM
DESIGN
MUNiCiPALITY OF ANCHORAGE
Department of Health and Human Services
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 16, Block 5, Riverview Subdivision
Request you issue a permit to iustall a septic system to serve the proposed four
bedroom house on the referenced property.
Txvo test holes were excavated and a percolation test was perfo~ned. The approximate
locations of the test holes are located on the attached site plan.
At the time of excavation, groundwater was encountered in the test hole #1 at 4 fi. After
seven day groundwater monitoring, the monitoring tube was checked and gn'oundwater
was found a 3 ft. In test hole #2, at the time of excavation, the groundwater level was at
9 ft. After seven day groundwater monitoring, the water level was unchanged.
We do not anticipate any adverse effects on neighboring wells, septic systems or
drainage patterns by the installation of the proposed septic system.
There are no points of contamination within the proposed well radius which can be seen
on the attached site plan.
If you require additional information, please contact us.
Sincerely,
Robe~l C. Cowan, P.E.
RCC/jlm
Enclosure
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577
1"=60'
SCALE
/
SITE PLAN
DESIGN
~£LLs ~I~IN 100' OF Z~ -- ~0TM
~m 0~o
~m~m mom
~ _.~-- rZm
O~mm
/ 4
N.T.S. DESIGN PROFILE
SCALE
o, , o, ~o.~
~uO
~ -
I I I ~
,~ , ,~ ~
' i ' "
I ~1 I
I ~1I ~
" " " ~s~'~ ~i .,.3~
, ,o ,
~ h .~ ," n~ ~,
PERFORMED FOR:
LEGAL DESCRIPTION:
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19-
2O
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
DATE PERFORMED:
Township, Range, Section:
I I
WAS GROUND WATER
ENCOUNTE"ED?
IF YES, AT WHAT
DEPTH?
Oeplh to Waler After.,
Moniloring? Date:
Gross Net Depth to Net
Reading Date Time Time Water Drop
PERCOLATION RATE __
(m~nutesCmch) PERC HOLE DIAMETER
TEST RUN BETWEEN __ FT AND __ FT
COMMENTS
$ & $ EblG~NEERING
17034 Eagle l,~iver Lot~p-RoadTNc,. =04 ' ~:"
PERFORMED B,~agle [,iver, &t~,, 99577 /ff~(~/2 &~ ~'- CER]IFY THA% THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFEC] ON THIS DATE' DATE: ~ /I O~ ~[ ~"
72 008 (Rev, 4/85)
PERFORMED FOR:
LEGAL DESCRIPTION:
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
2O
COMMENTS
Municipality of Anchorage
DEPARTMENT OF HEALTH & HUMAN SERVICES
825 "L" Street, Anchorage, Alaska 99502-0650
SOILS LOG -- PERCOLATION TEST
DATE PERFORME::(~.'.
Township, Range, Section:
SLOPE SITE' PLAN
WAS GROUND WATER
ENCOUNTERED?
s
L
IF YES, AT WHAT j
DEPTH? ~ O
P
E
f,L~ ..¢'
Depth to Waler A~terq//.~ /
Monitoring? Dote:
Gross Net ~ N) Depth tO Net
Reading Date Time Time t'4, t Water Drop
6 ~ ] ~ ~/~".. ~/~"
PERCOLATION RATE /~ ,'"~ (m,nutes/,nch) PERC HOLE DIAMETER
TEST RUN BE'I'WEEN FT AND FT
S & $ i';'.N~INE. ERING / / .
..... -"-'~ I lA.-...-. CERTIFY THAT THIS TEST WAS PERFORMED IN
ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: L/ / l ¢~) (1 ~
72~008 (Rev. 4/85J
ROBERT C. COWAN, P.E.
HEALTH AUTHORITY
APPROVALS
SEWER & WATER
MAIN EXTENSIONS
SEWER & WATER
INSPECTION
ENGINEERING STUDIES
AND REPORTS
WELL INSPECTION
& FLOW TEST
SITE PLANS
ROAD DESIGN
SOILTEST
PERCOLATION
TEST
STRUCTURAL &
MECHANICAL
INSPECTIONS
ONSITE
W,~ST EWATE R
OISPOSAL SYSTEM
DESIGN
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
CIVIL ENGINEERS
(907) 694-2979
FAX (907) 694-1211
REFERENCE: Lot 16, Block 5, Riverview Subdivision
April 17, 1998
GENERAL:
The scope of this project includes the installation of a 1500 gallon
S.T.E.P.system, and a five foot wide drainfield to serve the proposed four
bedroom house located on the referenced property.
Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
The contractor shall be responsible for obtaining any necessary underground
utility locates.
Unless specifically agreed otherwise, the property owner shall be responsible for
final grading areas subsequently depressed fi'om soil settling. On all leachfield
mound systems, the property owner shall be responsible for ensuring a
satisfactory vegetation growth over the mound area.
Contractors installing wastewater disposal systems must be certiffed by the
Municipal Health Department for system installations. Owners installing their
own systems must also receive prior approval from the Municipal Health
Department.
SEPTIC TANK INSTALLATION:
A septic tank is to be constructed by a certiffed septic tank manufacturer.
Construction shall include two 4" cleanouts for pmnping access.
The septic tank shall be sufficiently bedded to prevent settling or shifting of the
tank.
All standpipes on the septic tank shall extend a miuimum of 12 inches above
final grade.
4. Septic tanks installed with less than 4 ft. of cover shall be insulated.
17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577
Page Two
Lot 16, Block 5, Riverview Subdivision
April 17, 1998
A foundation cleanout shall be installed one to four feet fi'om the building foundation.
In the line between the tank and the leachfield there shall be two adjacent cleanouts
(unless an effluent pumping system exists within the septic tank). These cleanouts shall
be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in
line, shall be to clean toward the leachfield. The second cleanout shall be to clean
towm'd the septic tank.
Final grading over the septic tank shall be such that a positive slope exists axvay from
the septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of
the excavation shall be within 2 inches of level. If the sidewalls of the excavation
become smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock)
placement.
Once the gravel is installed, the distribution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over the distribution pipe to
provide a minimum of 6 inches of cover over the pipe.
A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt bmTier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed approximately in the
locations shown on the design, and extend a minimum of 12 inches above final grade.
The portion of the monitoring tube extending through the gravel shall be perforated
fi'om the bottom of the trench to the invert of the distribution pipe. This is equivalent to
the effective depth of the gravel as noted on the design.
Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches.
The finish grade over the trench must be mounded to prevent the formation of a
depression after settling.
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must be constructed by a Municipal approved
septic tank manufacturer.
The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Page Three
Lot 16, Block 5, Riverview Subdivision
April 17, 1998
Type of Pipe Perforated
Solid
Cast Iron Yes
ASTM D3034 (PVC)' Yes
ASTM F810 (HDPE) Yes
ASTM D2662 (ABS) Yes
Yes
Yes
No
Yes
Use of a type of pipe other than listed above must be approved by the inspecting
engineer.
Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco,
or equal).
A pe~rneable nontoxic silt barrier (Typar 3401, Mirafi 140N, or eqnal) must be installed
between the final leachfield gravel layer and the native soil backfill.
All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
When sand is being used as a filter material, its gradation specifications must conform
to CUlrent M.O.A. or D.E.C. requirements, which ever requirement applies.
INSPECTIONS:
Typically there will be a minimum of thi'ee (3) inspections required during the installation of
the wastewater disposal system. These inspections will occur as follows:
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading of the property.
Page Four
Lot 16, Block 5, Riverview Subdivision
April 17, 1998
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting
engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a
pre-construction meeting will take place on-site. The inspecting engineer will not coordinate,
direct or control in any way the contractors activities.
The owner shall contract with the contractor to perform the work outlined in these
specifications and plans and in accordance with the attached M.O.A. pernfit. There will be no
contractual arrangement existing between the contractor and S & S Engineering. S & S
Engineering shall be the owner's representative and will inspect the work as stated above to
document the contractors activities. Final acceptance of the contractors work rests with the
owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons perforating work on this project or the failure of the contractor
to carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedm'es or the safety precautions incident to this project.
CONTRACTOR//NSTALLER
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(907) 343-790-1
CERTIFICATE OF HEALTH AUTHORITY APPROVAL
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 050-792-17
1. GENERAL INFORMATION
Complete legal description
HAA#
Expiration Date:
Lot 16, Block 5. River Vie,,,; Estates Subdivision
Location (site address or directions) 7401 Watedall Drive
Current Property owner(s) ~,tfi1&M Ccntractino
Day phone 688-t236
Mailing address
Lending agency
P.O. Box 670495 Chuciak, AK 99567
Day phone
Mailing address
Real Estate Agent
Day phone
Mailing Address
Unless otherwise requested, HAA will be held by DSD for plckup.
2. NUMBER OF BEDROOMS: Three(3)
3. TYPE OF WATER SUPPLY:
Individual Well
Individual Water Storage
Community Class
Public Water System
Well
TYPE OF WASTEWATER DISPOSAL:
[] Individual On-site []
[] Individual Holding tank []
[] Community On-site []
[] Public Sewer []
The Municipality of Anchorage Development Se,vices Department (DSD) Issues Certificates of Health Authority
Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil
engineer registered in the State of Alaska. Certificates of H,~alth Authority Approval are required for the transfer of
title (except between spouses) for properties served by a single family on-site wastewater disposal and;or water
supply system. DSD a!so issues HAAs upon request to homeowners. Certificates of Health Authority Approval are
valid for 90 days from the date of issue for properties seined by a private or Class C well and may be reissued with
new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with
valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public
waIer syslem. The Municipality of Anchcrage is not responsible for errors or omissions in the professional
engineer's wcrk.
4. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation dale shown below, I verify that my investigation,
based on procedures oullined in the Health Authodly Approval Guidelines for this application, shows that the
on-sile water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of
bedrooms and type of structure indicated herein. I fudher verify Ihat based on the information obIained from the
Municipality of Anchorage files and from my invesfigafion and inspeclion, the on-site water supply and/or
wastewater disposal system is(are) in compliance with a~l applicable Municipal and Slato codes, ordinances,
and regulations in effect at the time of installation.
Name of Firm Anderson Enqineerinq
Address P.O. Box 240773 Anchoraae, AK 99524
Engineer's Printed Name I~,lichael E. Anderson, P.E.
Phone 522-7773
Dale 11/17/02
5. DSD SIGNATURE
~ Approved for _'~
Disapproved.
Conditional approval for
bedrooms.
bedrooms, with the following stipulations:
Additional Comments
Attachments:
HAA Checklist
Septic System Advisory
Wall Flew Advisory
X
Maintenance Agreements
Supplemental Engineer's Report
Other
Original Certificate Date: / i - ~ l- 0 ..~-._
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water & Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak.us
(9O7) 343~79O4
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: Lot 16, Block 5, River View Estates
A. WELL DATA
Well type Pri~ate
Date completed 6F~/2002
Total depth 120 ft.
if A, B, o~ C provide PWSID #
Sanitary sea~ (Y~N) ~_
Cased to .~I ft.
FROM WELL LOG
Date o¢ test
Static wal~' tevel
Well production
WATER SAMPLE RESULTS:
0 ff.
7 gp.m.
Bo
Ce
Parcel ID: 050-792-17
Well Log (Y/N) Y
W~res properly protected (Y/N) Y
Casing height (above ground) >24
AT INSPECTION
tl/9r2oo2
o ft.
5.5,,1 g.p.m.
in.
Coliform 0 colonies/19o mi.
Date of sample: 11J9/2002
SEPTIC/HOLDING TANK DATA
Tank Type/Material Sl'EP/Stesl
Tank size ~.250 gal.
Foundation cleanout (y/N) y_
Date of puh~ping
ABSORPTION FIELD DATA
Date installed 7/24/2~2
Length 54
Total depth 5.~ ft.
Dale of adequacy test
N~ate .6 mg./L
Coaested by: MEA
Other bacleda {} colonies/lO0 mi,
Fluid depth in absorption field before test in. Water added . gal.
Elapsed Time: min. Final fluid depth, in. Absorption rate >=
Any rejuvenalkm treatment (past 12 mo.) (YIN & type) N
If yes, give date
Number of Compartments 3_
Depression Over tank (Y/N) N
Pumper New Constm~on
Date installed 7/19/2{X)2
Cteanouts (Y/N) v
High water alarm (Y/N) Y
' Soilrating (g.p.dJft~orft;/bdrm)12GPD/S., F System type 5' Wide Trench
ft. W~dth $ ft. Graval below pipe 2
Eft. absorption area .3~5.7~f~ Monitoring tube Y_ Depression over field _N
Results (Pass/Fail)
For. bedrooms
New depth in.
g.p.d.
D. LIFT STATION
Date installed 7/19/2002
'Pump on' level al 42 in.
Datum Bottom of Tank
SEPARATION DISTANCES
Size in gallons 250
'Pump off" level at 42 in.
Cycles tesled
SEPARATION DISTANCES FROM WELL ON LOT TO:
Septic tank/lift station on lot >100'
Absorption field on lot >100.
Public sewer main N/A
Sewer/septic service line >25*
Property line >t0'
Water Service line >10'
Curtain drain None Noted
F. COMMENTS
ManhoteJAccess (Y/N) Y'
High water alarm level at 44
Meets alan"n & circuit requirements? Y
On adjacent lots >!00.
On adjacent lots >t00'
Public sewer rnanhole/cleanout N/A
Holding lank
in.
SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5*
Waler main N/A Water service line >10'
Wells on adjacent lots >t00.
SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO:
Building foundation >t0'
Surface water >100'
Wells on adjacent lots >t00'
G. ENGINEER'S CERTIFICATION
Absorption field >5'
Surface water >t00.
Water main >t0.
Driveway, pa~Jng/vehicte sto~age >25'
I certify that I have determined through field inspeclfons and
review of Municipal records that the above systems are in
conformance with MOA HAA gu~eli~es in effect on this date.
Engineer's Printed Name Michael E. Anderson, P.E.
Date 111t5/02
HAA Fee S
Date of Payment
(Rev. ~)
..':.
Wa~ F~ $
Date ~ Paymenl
R~ipt Num~
Oct. 14 ~ ~?l~:'Pt'l P4
Rec.eived T!me.'Oct. 14,-
11-15-.0Z 10:11 FROI,~CT&E ENVIROHR~NTAL SRV
'~t~'. CT&E Environmental ,Services Inc.
9075615301
T-750 P.03/03 F-243
CT&F_. Ref.#
Client Name
Prole~ Name/~
Client Sample ID
Matrix
PWSID 0
Sample Remarks:
1027768003
.A~dcr~on ,~ng~eering
Various
Lot 16, Block 5, Rivet View
D~'i.~i~g Water
All Datesffl'lmes are Alasl~ Standard Time
Printed Date/Time 11/15/2002 10:23
Collected Date/Time I lit 1/2002 12:30
Rerelved DateFl'lme 11111/2002 16:00
Technical ~ Step~C. £de
Result~
PQL
Units Mc~od
ABowehle Prep Anal/sis
Limits D~tt~ Date Init
Wa~:o~a Depa~'tmemt:
Nitrate*N
0.600 U
0.600 mrS- EPA 30o.0
11/12/02
~.crob:Lolos3~ Labo:ato:~'
Total Coliform
col/100mL SM 18 92.?.2B
11111/02 KAP
Received Time Nov.15. IO:I7AM