Loading...
HomeMy WebLinkAboutKNIK VIEW ESTATES BLK 3 LT 6 & 7Knik Vi w Estetes Block Lot 6&7 #051-043-60 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bmgaw St. P.O. Box 196650 Anchorage, AK 99519-6650 Page www.ci.anchorage.ak, us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: .~ (,",.) 0~0 I 6~ PID Number: N*~e:~O{~ ~~]~ WastewaterSystem: ~New DUpgrade ~ ~a~ ~ ~9/e~V~ ~qS~ ABSORPTION FIELD Township: LEGAL DESCRIPTION Range: Secti(~c Well: [] New [] Upgrade Cla~ificaden(Pfivate. A,,B.C}: t # To~alDep~ Casedto: FL  Sta§c Water Levek Fi.I Ft. SEPARATION DISTANOES Septic Absorption Lift Holding Tank Field Station Tank Installer. TANK - LIFT STATION ~Manufacturec ~ in, 'n, in. BENCH MARK S & S ENGINEERING Eagle River, Alaskd ~577 D ev el o p m e,r~.~,c¢~)~p.~ ~tJ:~ n} Approval PERMIT NO. 5W020163 PAGE 2 OF 4 Municip. a~it: oF Anchoraae DEPARTMENT OF HE~[TH AND HUMAN SERVICES ENWRONMEN'rAL SERVICES P,Q. Box 195650 ~Anchopage, A%aska 99519-6650eTe(ephone: 343-4744 ON-S~TE WASTEWATER D~SPOSAL SYSTEM AND/OR WELL ~NSPECT~ON REPORT LEGAL LOT 68::7, BLOCK 3, KNIK VIEW ESTATES / / / ALT SiTE / (INASTALLED) TH#2 P.[.D. NO. 051-045-60 -KEYBOX / / / ' / ALT, SITE CRITERIA: / 4.5' EFFECTIVE DEPTH 42' LONG EACH / N/EW TRENCHES / / NEW 1250 GALLON :TIC TANK / ~T2 / / )BL1 & DB~2 (DIVERTER VALVE) LOT 6 ~SCALE: 1" = 30' ...... ,.,. / ' ::.. ~ '~..F.~,:'-.,. PERMIT NO. SW020163 PAGE 3 OF 4 iVlunicip, o, tid: oC Anchor-'o. c3e DEPARTMENT OF HEA~THAND HUMAN SERVICES ENVIRONMENTAL SERVICES D~VISION · P,~. Box 196650 ~_Ancho~'oge, ALcskc 99519-6650·Te[ephone~ 343-4744 ON-S~TE WASTEWATER U~SPOSAL SYSTEM AND/OR WELL INSPECTION REPORT LEGAL LOT 6&7, BLOCK 3, KNIK VIEW ESTATES P.[.D. NO. 051--043--60 FINAL S_T1 S T_~....- 99.0' GRADE-/ 2" /- INSULATION GALLON SEPTIC TANK A B FCO ~ 7.0' ST1 43.5' 17.5' ST2 49.5' 25.5' DBL1 53.0' 30.5' BBL2 54.0' 31.5' DV 54.5' 32.5' FS1 68.0' 57.5' FS2 48.0' 48.5' C01 65.5' 45.5' MT1 67.5' 47.0' C02 84.5' 77.0' MT2 85.0' 77.0' C03 52.5' 36.0' MT3 54.5' 38.0' C04 74.5' 71.0' MT4 71.5' ' 68.5' C05 42.0' 30.0' MT5 43.5' 31.0' C06 66.0' 68.5' MT6 66.5' 67.5'- C07 32.0' 29.0' MT7 33.5' 32.0' C08 61.0' 69.0' MT8 61.0' 68.5' PERMI? NO. SW020165 PAGE 4 OF 4 ~nicip. o, Li~ of Ancho:'o, ae DEPARTMENT OF HE.~[THAND HUMAN SERVOCES ENVIRONMENTAL SERVICES D~V~SDON . P.O. Box 196650 ~ncho~age, ALaska 99519-6650 ~TeLeDhone: 343-4744 ON-$~TE WASTEWATER UISPOSAL SYSTEM AND/OR WELL ~NSPECT~ON REPORT LEGAL LOT 6&:7, BLOCK 5, KNIK VIEW ESTATES P.i.$. NO. 051--043-60 CO1 =97.4' -_-/C02=98.6' FINAL / ~~" GRADE [ ~ . MTl=88.0'~ MT2=88.2' C03=99.4' _._/C04=99.7' INSULATION C02=93.0' . C04=93.2' MT5=88.2'~ MT4=88.2' C05=99.6' ___/C06=99.3' FINAL GRADE "i~ CO5=92.7' MT5=88.0' MT6=88.0' C06=92.6' ~ MT7=88.1'~ MTn=88.1' · NO WATER FOUND 82.5' B.O.H. C07=99,5' __._/C08=100.5' C07=92.6' C08=92.6' MUNICIPALITY OF: ANCHORAGE Development Sen/ices Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Jun 12, 2002 Expiration Date: Jun 12, 2003 Permit Number: SW020163 Legal Description: KNIK VIEW ESTATES BLK 3 LT 6 & 7 Design Engineer: 0003 S & S Engineering Owner Name: Mike & Johnny Snell Owner Address: PO Box 670657 Chugiak, AK 99567- Parcel ID: 051-043-60 Site Address: 021902 REBECCA CIR Lot Size: 43583 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [~ Disposal Field [] Septic Tank [] Holding Tank ~ Privy Private Well ~] Water Storage All construction must be in accordance with: 1. The attached approved design, 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15,65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: ~~'/~- ~ Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St, P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 6~-/- ~)/'t/'~''' ~_OO Permit Number Property owner(s) Mailing address (1) Mailing address (2) kegal description (Lot, Block & Sub'd.) ke~al description (Section, Township Acres Sq. Ft. THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool :~, 3'oA i~I 5' 1~ 6 LL Day phone Number of Bedrooms '/~ Well Only [] Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. ' S 8, S ENGINEERING (Signature of property owner or authorized agent) 17034 Eagle River Loop Eoad, NO, :204 Eagle River, Alaska Permit Fees: /n/ (2 O. <'' ~ Waiver Fees: Date of Payment: 5'-' / ) ¢ / O 2- Date of Payment: Receipt Number: O I ~ 5" .,t' ~. Receipt Number: (Rev. 12/00) May 7, 2002 ROBERT C. cOWAN, P.E. CIVIL ENGINEEP-~.q (907) 694-~'979 FAX (907) 094-121 'i SEWER&WATER MAIN EXTENSIONS MUNICIPALITY OF ANCHORAGE Development Services Department P.O. Box 196650 Anchorage, AK. 99519 REFERENCE: Lot 6 & 7, Block 3, Knik View Estates S/D SEWER &WAIER INSPECIION ENGINEERING STUDIES ANDREPORTS WELL INSPECTION & FLOW TEST SITE PLANS ROAD DESIGN SOILTEST PERCOLATION TEST It is requested that you issue a permit to install a septic system to serve the proposed four bedroom dwelling on the referenced property. A test hole was excavated and a per~colation test was performed. The approximate location of the test hole is located onthe attached site plan. Atthe t'mae of excavation on 1/18/02 no water was found. After seven days of ground water monitoring the test hole was still found to be dry. We do not anticipate any adverse effects on neighboring wells, septic systems, reserve areas or drainage patterns by the installation of the proposed septic system. The construction of this system will not prevent any future development on any of the adjacent properties. If you require additional information, please contact us. Sincerely, RCC/jhm Enclosure STRUCTURAL& MECHANICAL tNSPECTIONS ONSITE W.~T EWATER DISPOSAL SYSTEM DESIGN 17034 NORTH EAGLE RIVER LOOP ° SUITE 204 · EAGLE RIVER, ALASKA 99577 LOTS 6 & ?, BLOCK 3, R.C.C. 17054 EAGLE RIVER LOOP ROAD EAGLE RIVER, ALASKA 99577 PHONE# (907)694-2979 FAX# (907)694--1211 / / / d~NSTALL FLOW / J.H.M. DESIGN CRITERIA: 4 BDRM = 600 GPD SOILS = 0.8 GPD/SQ.FT. 600/0.8 -- 750 SO.FT. REQ'D. TRENCH CRITERIA: 8' DEEP 5' EFFECTIVE 2.5' WIDE 75' LONG(2@ ,38' LONG) -KEYBOX ALL PORTIONS OF SYSTEM WITH LESS THAN 5.5' OF COVER REQUIRE INSULATION. KNIK VIEW ESTATES S/D I° .... 5-9-02 I ~,~Eo: 5- 3 1 - 0 2 20 F 2 STRUCTURES, EASEMENTS, OR ENCROACHMENTS SHOWN ON TH~S SITE PLAN ARE AS SHOWN ON AN AS-BUILT SURVEY DRAWN BY: WILLIAM D. FLEMING IT IS THE RESPONSIBILTY OF THE CONTRACTOR TO VERIFY EASEMENTS, REQUIRED SEPARATION OISTANCES, AND PROPERTY LINES PRIOR TO CONSTRUCTION. WATER /SERVICE LINE ~. 69' MT CONTRACTOR IS REQUIRED TO OBTAIN UTILi~ LOCATES PRIOR TO ANY EXCAVATION WORK. INSTALL ~':~/ ~ 8 NEW 1300 ~ OALLON HDPE / SEPTIC TANK ' ..... ~ INSTALL DOUBLE CLEANOUT NEW TRENCHES lO PROPERTIES .SERVED BY COMMU SYSTF~. NO WELLS WITHIN 200' SEPTIC/ SYSTEM. LOTS 6 & 7, ~3LOCK 3, J.H.M. ] R.C.C. ineering DESIGN CRITERIA: 4 BDRM = 600 GPD SOILS = 0.8 GPB/SQ.FT. 6oo/o.8 = 75o SO.FT. r~Eq'D. TRENCH CRITERIA: 8' DEEP 17054 EAGLE RIVER LOOP ROAD 5' EFFECTIVE EAGLE RIVER ALASKA 99577 o PHONE# (907)69 29 7:~ /t~klC'[Or',~ ~' /f~kl~-\ / / FAX# (907)694 1211 / 14 /' / , .-' / / /// j/ . FLOW -- ,'ff ./' /,,- KNIK VIEW ESTATES S/D ] .... 5-9-02 .e,,sEo: 5-51-02 1 OF 2 STRUCTURES, EASEMENTS, OR ENCROACHMENTS SHOWN ON THIS SITE PLAN ARE AS SHOWN ON AN AS-BUILT SURVEY DRAWN BY: WILLIAM D. FLEMING IT ~S THE RESPONS~ERLTY OF THE CONTRACTOR TO VERIFY EASEMENTS, REQUIRED SEPARATION DISTANCES, AND PROPERTY LINES PRIOR TO CONSTRUCTION. / FCO., ~W 1300 GALLON HDPE SEPTIC TANK DOUBLE CLEANOUT / NEW /' x. / y~.,,. TRENCHES / WITHIN ALL PORI[ONS OF SYSIEM WiTH LESS THAN 3.5' OF ~ // COVER REQUIRE INSULATION. 8 PROPERTIES ,,,~'VED BY SYSTE)~. NO WELLS SEPTW/SYSTEM. ~"&¥',-"' "'[""..'~' i%-': / OBTAIN UTILI~ LOCATES / PRIOR TO A~Y EXCAVATION / 10 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www. ci.anchoraae.ak.us (907) 343-7904 Soils Log - Percolation Test (Fe.,?t) l- s- 10- ~2- 14- 20- COMMENTS PERFORMED PERFORMED Slope / WAS GROUND WATER ENCOUNTERED? ~'~ C> S iF YES, AT WHAT DEPTH? -- L O Depth to Water After ~ [ Monitoring? Reading Date PERCOLATION RATE TEST RUN BE'DNEEN Date.Pe,o~ed: ' // t~ / O ~ Township. Range. Sec~on: Site Plan Gross Time Net Time Depth to Water Net Drop o o I' ) .~. (minute$/~nch) PERC HOLE DIAIvIETER ~, ~ ~ FT AND ~' FT BY: ~v~"~..'/..~~ I "~//~/..__ CERTIFY THAT THIS TES~T WA~ IN AC(~O~DANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN L~FF~CT ON THIS DATE. DATE: //'-~-,Y'/O ~,. SEWER & WATER MAIN EXTENSIONS SEWER&WATER INSPECTION ENGINEERING STUOIES ANDREPORTS WELL INSPECTION & FLOW TEST SITE pLANS ROAD DESIGN SOIL TEST F'~ROOLATION TES. T STRUCTURAL & MECHANICAL INSPECTIONS ON SITE W,~S'FEWATE R O~SPOSAL S~TEM DESIGN ROBERT C, COWAN, P,E, CIVIL ENGINEERS (907) 694-2979 FAX (907) 694-1211 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION PRACTICES and MATERIAL SPECIFICATIONS REFERENCE: Lots 6 & 7, Block 3, Knik View Estates S/D May 7, 2002 GENERAL: The scope of this project includes the installation of a 1300 HDPE gallon septic tank and new trenches to serve the proposed four bedroom residence located on the referenced property. Construction shall be in accordance with the approved site plan and design drawings, Municipal permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The contractor shall be responsible for obtaining any necessary underground utility locates. Unless specifically agreed otherwise, the property owner shall be responsible for final grading areas subsequently depressed from soil settling. o Contractors installing wastewater disposal systems must be certified by the Municipal Health Department for system installations. Owners installing their own systems must also receive prior approval from the Municipal Health Department. SEPTIC TANK INSTALLATION: A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 17034 NORTH EAGLE RIVER LOOP · SUITE 204 · EAGLE RIVER, ALASKA 99577 Page 2 Lots 6 & 7, Block 3, Knik View Estates S/D May 7, 2002 All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. Septic tanks installed with less than 4 ft. of cover shall be insulated. A foundatio.n cleanout shall be installed one to four feet from the building foundation. In the line between the tank and the leachfield there shall be two adjacent cleanouts (unless an effluent pumping system exists within the septic tank). These cleanouts shall be located on undisturbed soil not more than 10 ft. from the tank. The first cleanout, in line, shall be to clean toward the leachfield. The second cleanout shall be to clean toward the septic tank. Final grading over the septic tank shall be such that a positive slope exists away from the septic tank. ABSORPTION TRENCH/DRAINFIELD INSTALLATION: Excavate the proposed trench to the dimensions shown on the design. The bottom of the excavation shall be within 2 inches of level. If the sidewalls of the excavation become smeared, they must be raked or scratched (rafted-up) before gravel (sewer rock) placement. Once the gravel is installed, the distribution pipe is to be installed level with the perforations faced downward. Gravel is then to be placed over the distribution pipe to provide a minimum of 2 inches of cover over the pipe. A silt barrier must be installed between the final gravel layer and the native soil backfill. Ensure the silt barrier covers the entire gravel surface before placing backfill. Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations shown on the design, and extend a minimum of 12 inches above final grade. The portion of the monitoring tube extending through the gravel shall be perforated from the bottom of the trench to the invert of the distribution pipe. This is equivalent to the effective depth of the gravel as noted on the design. Backfill over the final gravel layer must not be less than twenty-four (24) inches. Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The finish grade over the trench must be mounded to prevent the formation of a depression after settling. Page 3 Lets 6 & 7, Block 3, Knik View Estates S/D May 7, 2002 MINIMUM MATERIAL SPECIFICATIONS: 1. Any septic tank proposed for installation must be constructed by a Municipal approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Type of Pipe Perforated Solid Cast Iron Yes Yes ASTM D3034 (PVC) Yes Yes ASTM F810 (HDPE) Yes No ASTM D2662 (ABS) Yes Yes Use of a type of pipe other than listed above must be approved by the inspecting engineer. 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Company Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). A permeable nontoxic silt barrier (Typar 3401, Mirafi 140N, or equal) must be installed between the final leachfield gravel layer and the native soil backfill. 6. All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3% passing the #200 sieve. 7. When sand is being used as a filter material, its gradation specifications must conform to current M.O.A. or D.E.C. requirements, which ever requirement applies. INSPECTIONS: Typically there will be a minimum of three (3) inspections required during the installation of the wastewater disposal system. These inspections will occur as follows: Page 4 Lots 6 & 7, Block 3, Knik View Estates S/D May 7, 2002 The first inspection must be conducted after the excavation of ditches, pits, trenches, or beds and before the installation of any gravel, A septic tank may be set in place, but may not be backfilled before this inspection. The second inspection must be conducted after the placement of the silt barrier, gravel, distribution lines, standpipes, cleanouts, and insulation, but before the placement of any other backfill. 3. The final inspection is to occur upon final grading of the property. Often there will be more than these 3 inspections required. Especially with the installation of multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre- construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or control in any way the contractors activities. The owner shall contract with the contractor to perform the work outlined in these specifications and plans and in accordance with the attached M.O.A. permit. There will be no contractual arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be the owner's representative and will inspect the work as stated above to document the contractors activities. Final acceptance of the contractors work rests with the owner and the M.O.A. S & S Engineering shall have no liability to the owner or to others for acts or omissions of the contractor or any other persons performing work on this project or the failure of the contractor to carry out the work in accordance with these construction documents. S & S Engineering's inspecting engineer will not be responsible for the construction means, methods, techniques, sequence, procedures or the safety precautions incident to this project. CONTRACTOR / INSTALLER 2002-038731}-0 Recording Dist: 301 - Anchorage 6/10/2002 2:09 PM Pages: I of 1 II Iltll IIII II IIII Ill II IIIII I II II Illl II II IIIII I IIII II lll li ]~ASEMENT JUDD WALKER, hei'einaP, er referred to as Grantor, whose address is 1001 Boniface Parkway, Anchorage, AK 99504, owfler o£the land descn'bed as: Lot 6; Block 3; Knik View Estates, as per pht thereof recorded in the Anchorage Recording D/mic~ under plat file number ~6 -I I.J . For good and valuable consideration, the receipt of which is hereby acknowledged, hereby grants and conveys Io SUDD WALKER, whose address is 1001 Boniface Parkway, Anchoraga, AK 99504, the followin~ easement to be used for ingress, egress and utilities. The easement granted is described as: An easement t'or a Wastewater Disposal System access over Lot 6, Block 3, Knik View Estates Subdivision for use by owner and tenants of Lot 7; Block 3; Knik View Estates Subdivision, as pcr plat thereof recorded in the Anchorage Recording DistrJcl under plat file number ~6 --//$, and further described as follows: This easement is for the benetrR of and peflinent to that land and any portion thereof described as: Lot 7; Block 3; Knik View Estates Subdivision Grantors, ~eir heirs, successors and assigns, agree to said ingress, egress, and utility easements and their use by JUDD WALKER, his heirs, successors, and assigns. JUDD WALIO~R and his successors in tmerast, shall use the rights granted above with due regard to the rights of others in their use thereof. Grantors, and their successors in Jmerest, shall no! obstruct the easement in any way. Cn'anlccs and their successors in interest 61 8 9 Ip • ,f45...�� 7 7 '� Municipality of Anchorage % ,:`-`� I ' On-Site Water and Wastewater Program � ,t (907) 343-7904 c qL fil r il^'_8 n d 1 ti Certificate of On-Site Systems Approval ��4' •hw Parcel I.D. 051-043-60 Expiration Date: L( Zc—j7 1. GENERAL INFORMATION Complete legal description Knik View Estates Block 3 Lot 6&7 Location (site address) 21912 Rebecca Circle Current Property owner(s) Timothy&De Etta Page Revocable Living Trust Day phone Mailing address PO Box 670332 Chugiak, AK 99567 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex LI Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual 0 Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System 2 Public Sewer ❑ WaiverNariance request for: Distance: Received by: _ i1 ' (Q, j Date: COSA to be released to the engineer,unless otherwise requ sted the engineer. COSA Fee $ 6--g.4, Waiver Fee $ Date of Payment qM to/17 Date of Payment Receipt Number 1(3./5-96 Receipt Number COSA# 616C-17//7Z/ Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal.system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes, ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system. The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 272-8218 Address P.O. Box 100217, Anchorage Ak. 99510 Engineer's Printed Name Steven R Pannone Date 4/24/2018 co.- � il . 49 TM * I 6. DSD SIGNATURE % V�I) rA System#1 Approved for bedrooms •-eri �� none: s% CE-8149 / System #2 Approved for bedrooms . �� 9s' �' ��k�`�P40FESSIOt,A 4 .. Disapproved 1\\N"`,�.`„ Conditional approval for bedrooms, with the following stipulations: `jt•• Alva; '...i0.�_S1It f WPB S. ��P ER o 00 n � C j. X22 --( 7 By: J ttiv,_ i Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet_f . . If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: Knik View Estates Block 3 Lot 6&7 Parcel ID:051-043-60 A. WELL DATA Well type Public If A, B, or C provide PWSID# Well Log (Y/N) Date completed Sanitary seal (Y/N) Wires properly protected (Y/N) Total depth ft. Cased to ft. Casing height(above ground) in. FROM WELL LOG AT INSPECTION Date of test Static water level ft. ft. Well production g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate mg/L Arsenic ug/L Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Date installed 7/23/2002 Tank size 1250gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm (Y/N) N/A Date of pumping L.2j,—10 Pumper 4 rS C. ABSORPTION FIELD DATA Date installed 7/23/2002 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 GPD/SF System type Deep Trenches Length 2 @ 40 ft. Width 3 ft. Gravel below pipe 5 ft. Total depth 9 5 ft. Eff. absorption area 800 ft2 Monitoring tube Y Depression over field N Date of adequacy test 4/20/2018 4Results(Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test in. Water added 600 gal. New depth CO in. Elapsed Time:‘eu min. Final fluid depth —1 in. Absorption rate >= 600+ g.p.d. N Any rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off" level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot On adjacent lots Absorption field on lot On adjacent lots Public sewer main Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10+ Property line 5+ Absorption field 5+ Water main 10+ Water service line 10+ Surface water 100+ Wells on adjacent lots 100+ ABSORPTION FIELD ON LOT TO: Property line 10+ Building foundation 10+ Water main 10+ Water Service line 10+ 10+ Surface water 100+ Driveway, parking/vehicle storage Curtain drain 50+ Wells on adjacent lots 100+ F. COMMENTS Survey on file. G. ENGINEER'S CERTIFICATION SOF Ai,Q�kih I certify that I have determined through field inspections and ,��aj'�lp- -.,1"-- 11 review of Municipal records that the above systems are in 0*; , • I I N -.*y conformance with MOA COSA guidelines in effect on this date. I•...= S T 9/18/02 AS BUILT j 56-44 . 4,25/02 PLOT PLAN 54-53 A14‘ '\ DATE _ FLD. BK. REBAR YAR THIS �•' 11`�� COR. DISlURBsD. �t�.'• *.7ftsral.4. i a ' S 41°27'33'E 246.68' (R) I • '•• r + 0 Auto D. Fleming S 4 1°28'05"E 246.74' (A4) 1 o�••• : g ��' ?s,8 M I ! ♦ o, . LS-5773 cC � I 1 O '• •• a 8 I 1 $ ♦� %ar930: at...+ GR/C1F.L DRItF i aj Ety1 � , Ilk 1111&%1161116 w a LtN��PL.LtSEtA a 0 z lr, I PO , to NOTES: Easements not appearing on record subdivision `2.' 6 c� sJ� I tc I w plat ore not shown unless description of eosement is L7 2 O • Z w 7h . I �, a r- `� , 1 N ti provided by client. It is the responsibility of The owner N iv X cam,. 7 a m In or builder, prior to construction, to verity proposed LL, i , o building grade relative to finish grade and utilities j 1« _ 32.9 - ,, + uoi connections, and-to determine -the existence of any .J w z In00.0 1 i z `c easements, covenants, or restrictions which do not U co ,,tl 32•I' C C.a0 ° + W appear on the recorded subdivision plot. C M e; 1—r- I S 41 26'40"E 256.54' (M) U N 1 BASIS .. 256.48' (R) I M Elevations based on assumed datum unless otherwise �c+ r o + �+ indicated, and bearings and distances are record data. — ct — I I o Z O I I O C) v 4" CLC SEPTIC ' 1 in 9 U CD STD-?1?rs (1W) 8 e: I Z v + WI — co- \ �° aSBs SBS Engineering W i- w0 6 Polc MEQ , 17034 cA6:t RNtR LOOP ROAD 1 QS� • ' E q xc• LADti MYLR,ALASKA 91577 o° ro °- co ?0 ' tit i `c' ill ' �; (907)594-2971) co 0 1 I d' I I Z I I LEGAL DESCRIPTION 1 1 N 4 I°27'57'W 253.77' (R) r LOTS 687, BLOCK 3, I i KN I K VIEW ESTATES 25I �J PL Al NO. SCALE \' GRID 86- I 13 l" 2.40' i NW 1558 , MATANUSKA ELECTRIC ASSOCIATION, INC. LETTER OF NON-OBJECTION May 22, 2018 Timothy L. Page and Deetta J. Page Revocable Living Trust Dated: October 13, 2003 PO Box 670332 Chugiak, AK 99567 Re: Lot 6 Block 3 Knik View Estates (Plat 86-113, Anchorage Recording District) Dear Tim and Deetta Page: MEA has no objection to the encroachment of a septic located in the utility easement as depicted on the attached as-built survey drawing, subject to the following conditions: 1. The improvement will in no way restrict or limit the current or future ability of MEA to fully enjoy the benefits of the easement for any and all utility purposes that it presently enjoys under the easement. 2. MEA will be held harmless by the landowner from liability for any and all damages or injury to any person or property that may result from the existing and future use of the easement by MEA, its contractors, or assigns. 3. MEA will be held harmless by the landowner for any and all liability arising out of or relating to any use of the easement by others under a Letter of Non-Objection. 4. The landowner will be liable for any damages caused to MEA facilities by the improvement in the easement. 5. The landowner will be responsible for any special construction costs incurred by MEA due to the improvement in the easement. 6. The landowner will assure compliance with all applicable safety codes relating to the improvement in the easement. 7. Use of this letter by the landowner, their successors or assigns will constitute acceptance of these conditions. 8. Alteration of these conditions shall invalidate this letter. 9. This letter is not effective unless it is recorded in the Anchorage Recording District before ownership of the referenced property is changed from the above named landowner. Sincerely, k Mann ..ez Land Servi.-s •n:ge \\( STATE OF ALASKA)SS- THIS IS TO CERTIFY that on this 22 day of May , 2018 before me, the undersigned, a Notary Public in and for the State of Alaska, duly commissioned and sworn as such, personally appeared Manny Lopez Known to me and to me known to be the individual(s) named in and who executed the foregoing instrument and acknowledged to me that he/she/they signed and sealed the same as a voluntary act and deed for the uses and purposes therein mentioned. IN WITNESS WHEREOF, I have hereunto set my hand and official seal the day and year first above written 5-Z6-zozo �YNiv Si� Notary Public in and of Alaska My commission expires , Return to: MEA, PO Box 2929, Palmer, AK 99645 0, • ,f ,'4G OF PA"' Municipality of Anchorage Development Services DeDar ment Building Safety Division On-Site Water and Wastewater Program 4700 Sou{hBragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 . . www.ci.anchorage.a k.tJs (907) 34:~-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING O Parcel I.D. 1. GENERAL INFORMATION Complete legal description Lot 6 Location (site address or directions) Current Property:,ewner(s) Rod Metcal£ Mailing address 654 Harp Cir. Lending agency Mailing address .. Real Estate Agent Mailing Address HAA # /1/,z) O2 05'qq Expiration Date: ~/S/OS and lot 7; Bloe~ ~T~ P~b~ Cir. Chug-iak Day phone Ea~le River,AK 99577 Unless otherwise requested, HAA will be held by DSD for pickup. 4 229-3028 NUMBER OF BEDROOMS: TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class ~ Public Water System Day phone Day phone TYPE OF WASTEWATER DISPOSAL: [] Individual On-site [] Individual Holding tank Well ~ Community On-site ~: Public Sewer The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given In paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Cedificates of Healtl~ Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal ai~d/or water supply system. DSD also issues HAAs upon request to homeowners, Certificates of Health AUthority Approval are valid for 90 days from the date of issue for properties served by a priva[e or Class C well and may be reissued with new water sample results less than 30 days old. (certificates may be reissued for a period of up to one year with valid water samples.) Certific'~tes are valid ~oi' one year for propedies served by Class A or B wells or a public water ay. stem. The Municipality of Anchorage i~ not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OFINSPECTION By ENGINEER As cedified by my seal affixed hereto and as oi' the ~aiidafion daie shown below, I verify that my Investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal Syi~terrl is(are) safe, functional and adequate for the number of bedrooms and typ? of structure indicated herein. I further Verify that based On the information obtained from the Municipality of:.~Chorage files and from my investigation and inspection, the on-site water supply and/or wastewater di,sl:J~s~i system is(are) in compliance With all applicable Municipal and Stale codes, ordinances, and regul~tiofiS in effect at the time of installation. Name of Firm S & S Engineering Address lT034 N. Eagle River Loop Ste. Engineer's Printed Name . Robert C. Cowan .. 4 bedrooms. DSD SIGNATURE Approved for Disapproved. 204 Ea~le Phone 694-2979 River, AK 99577 Date /~/~/O Conditional approval for bedrooms, with the following stipulations: Additional Comments Attachments: HAA Checklist X Septic System Advisory Well Flow Advisory '--'-- · WATER AND ~~ : WASTEWATER : ~ ' PHOG~M ~Jjjj))))))))))}) ,' Maintenance Agreements S[~pplemental Engineer's Report Other Original Certificate Date'./Z/3/O (Rev. 12~0) · IFT ST ,T ON Date installed "Pumpon' level'at Datum ir1: Size in gallons - ' _ "Pump off' level, at..: Cycle. tested. M~nhole/Access (Y/N) . in.. H~h water alarm level at Meets alarm & circuit requirements? ~S~e~tic:tahldlift statioii 'on lot~' Absorption field on lot Public sewer main on. adj; Iot.~ On adjacent lots Public sewer manhole/cleanout Holding tank SEPTIC/HOLDING TANK ON' LOT TO: SEPARATION DISTAN( ProPerty line Water Service line Curtain drain /~ Surtace'Water Ioo ~F TO~ Building '~"5-~ Water main Surface water ,/j) 0 ~'~"~'~ ~' wells on adjacent lots .g;-Og' ENGINEER'S CERTIFICATION I certify that/have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HA~guidelines in effect ~n this date. Engineer's Printed Name f'~O~ ~/Z./~- ~-~ ~c3/~-,,~ Date '). ~--,/3, ./I;) 'z.._. HAA Fee $ 3 7~'-'~° -f- /J"C~. *'* ~'/~;~'~R)"" Dateof Payment: i. Receipt Number (Rev. 12/01) . Waiver Fee.$ Date'ofP.ayment Receipt Number .... .. . REBAR NEAR THIS COR, DISTURBED. ~,~- GRAVEL DRIVE ~: - 25 A" P¥C SEPTtC 8 sTD-PIPE$ [TYP] . 0 0 5.0 CONC, 0 8 S 41 27:33 E 246.68' (Ri S 41~28'05"E 246.74' (Mi 7 ~ S 41°26'40"E 256.54' (M) BASIS ~. 256.48' (R) N 41~27TM 253.77' 5 v 9 9/18/02 4/25/02 DATE NOTES: Easem, plot are not st provided by cli or b~)~lder, prio building grode connection$~ ~[ eosements~ co~ oppeor on the' Elevofions bos~ indic(tted, LOTS 6&7, Bq KNIK VIEW, PLAT NO. 86-113