ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SW020336
Erma Martin
P.O. Box 110334 Anch., AK 99511
244-4083 Four (4)
LEGAL DESCRIPTION
Block: Lot: Subdivision:
Parcel 17A
Township: Range: Section:
12N 3W 35
Well: Existing
Classification (Private, A, B, C): Total Depth: Cased to:
Private
Ft.
Date Ddlled; Static Water Level:
Ft.
I Pump Set at: Casing P eight Above Ground:
Ft. Ft.
SEPARATION DISTANCES
GPM
T~ To Septic Absorption Lift Holding
Tank Field Station Tank
We, >100' >100' N/A N/A
Surfa~Wa~er >100' >100' N/A N/A
LotU.e >5' >10' N/A N/A
~o.nde,on >5' >10' N/A N/A
Cartai. Ora~n None Noted
Remarks:
PID Number: 017-092-31
Wastewater System: Upgrade
Soil Rating:
ABSORPTION FIELD
5' Wide Shallow Trench
3., 2 GPD/Ft2
Depth to pipe bottom from original grade: ·
2 Ft.
Fill added above original grade:
2 Et,
Gravel width:
608 Ft2
GS Express
Total Depth from original grade:
3.0
Gravel depth beneath pipe:
ASTM D3034 PVC
Date Installed:
9/3.8-19/02
TANK
[] Septic [] Holding [] S.T.E.P.
3ublic/Private Manufacturer:
SewerLine Anchorage Tank
Material:
>25' Steel
Location and Description:
Garage Slab
Existing Absorption Crib Pumped, Crushed
and Backfilled On Site. 2" Insulation Over
Line Under Driveway and Parking Area.
[] Other:
(~apaclty in Gallons:
1,250
Number of Compartments:
Two (2)
LIFT STATION - NONE ON LOT
Manufacturer:
"Pump off level et: in. High water alarm at:
Electrical Inspections performed by:
BENCH MARK
Assumed Elevation:
100.0 Ft.
Inspections performed by: Alan Harala Dates: Ist 9/18/02
2"~ 9/3.9/02
Department of Health and Human Services approval
Engineer's Stamp
· ... ---- ...
Permit No. SW020336 PID No. 017-092-31
Page 2 of 3
o
,00'0~:5 M,,O0,gOoO0 N
Existing Crib Pumped, crushed,
Backfilled and Abandoned.
o.
3nl~a M31AN3a"IO0
A B
St 41.3 37.5
S2 49.3 45.2
M1 64.9 50.0
C4 69.2 50.8
C5 57.1 65.0
,O0'05Z M,,O0,gOoO0 N
PLAN AS-BUILT
SCALE 1" = 50'
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW020336
017-092-31
Page 3 of 3
41'
<1
[---~ 1,250
87'75-/ [Septic
91.5
8.5'
86.8
90
Ge o t e x__tiLe..E.o b c..Lc
Dr'o4n f'ie[d Rock
86.8
78,0
38'
PROFILE
Scole: 1" = 10'
78,2
AS-BUILT
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT
Upgrade
Date Issued: Sep 11,2002
Expiration Date: Sep 11, 2003
Permit Number: SW020336
Legal Description: T12N R3W SEC 35 PARCEL 17A
Design Engineer: 0014 Anderson Engineering
Owner Name: Erma Martin
Owner Address: PO BOX 110334
ANCHORAGE, AK 99511-0334
Parcel ID: 017-092-31
Total Bedrooms: 4
Site Address: 014471 GOLDEN VIEW DR
Lot Size: 80404 SQ. FT.
Permit Bedrooms: 4
This permit is for the construction of:
~ Disposal Field [] SepticTank ~ Holding Tank ~ Privy
Private Well ~ Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Issued By: ,
Date:
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.cLanchorage.ak.us
(907) 343-7904
ON-SITE SEWER/MMELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. 017-092-31
Property owner(s) J~rna Martin
Mailing address (1) P.O. Box 110334 Anchora.qe, AK 99511
Mailing address (2) Zip Code
Legal description (Lot, Block & Sub'd.) N22tY ofW396' NWtl4 EWl/4 NWtl4
Legal description (Section, Township & Range)
Lot Size 'Q~es ~Z)/--~'/ Acres~
THIS APPLICATION IS FOR:
Sewer Only
Sewer and Well
Sewer Upgrade
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool
Therapy Po01
Permit Number SW
Day phone 244-4083
Section 35, T12N, R3W -'(Troc'{ 17A)
Number of Bedrooms Four (4)
[] Well Only []
[] Water Storage []
[] Jacuzzi []
[] Water Softening Unit []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees: ~,)~-] ~"~"~- Waiver Fees:
Date of Payment: ~'/z)f~/O ~ Date of Payment:
ReceiPt Number: ~ I¢).~7-~-I/+~______~___/Receipt Number:
(Rev. 12/00)
ANDERS'O.N ENGINEERING
P.O:..BOX 240773
.'~ ANCHORAGE:;:"AK. 99524':
522-7773 i' 522,6"~79 (EAX)
September 4, 2002
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
N 220' of W 396' NWl/4 SWl/4 NWl/4, S35, T12N, R3W
Septic System .Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the subject lot intends to upgrade the septic system on the property to
accommodate a four-bedroom home. We are therefore requesting a permit be issued
for the construction of a new septic system to serve the home. The lot is currently
served by an existing well: The attached Site Plan and backup documentation identify
the location and configuration of the new septic system and the parameters used in the
design. Also identified on the plans are the well location, test hole location and the
locations of the existing absorption crib on adjacent lot. Drainage arrows are also
shown and current drainage patterns wiii be maintained after construction.
The test hole placed near the location of the proposed absorption trench indicated fairly
clean well graded to poorly graded sand with varying amounts of silt and a percolation
rate of 2 to 5 minutes per inch in the accepting layer. We are therefore proposing to
construct a deep absorption system with a 3' wide by 35' long trench with an 8' effective
depth. The distribution piping depth will be 2' below the surface. Total depth of the
trench will be 10'. The existing absorption cdb on the lot will be pumped, crushed and
baokfllled. The sewer service line from the house will be insulated with 2" of direct bury
insulation to prevent freezing.
The ground surface on the lot slopes as shown on the attached Site Plan with 2% to 3%
slopes from south to north. The slope from the house to the new septic tank, however,
drops off steeply and then flattens out toward the new absorption trench. The new
septic tank will require insulation and fill for adequate frost protection. The absorption
trench will be constructed parallel with the slope in conformance with Municipal
requirements. All components of the new septic system will be constructed a minimum
of 100' from the well on the lot. The system will also be constructed a minimum of 100'
from any surface water in the area.
If the system is constructed in accordance with our design the following statements
apply:
North 220' of West 396' Section 35
'September 4, 2002
Page Two
]. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael [. Anderson, P.E.
Attachments
TRACT
~09)49'0~'W
TRACT
?
367.13
~89157'36'E 397-13 HVL
N89]55'35'E 397.13 83-293
AREA SYSTEM PLAN
SCALE 1" =A00'
264.09
S89358'~, 4'W 9~5,32
,~,00,C30o00 N
Existing Well
~sorption Trench
~/ ~/ X_8' Effective Dop~
z
NO~E:
Pump, Crush and
Abandon Existing
Crib.
Place 2" Insulation Over
Service Line Under Driveway.
3AI~O /~IAN30]09
,O0'OZZ ~,,O0,gOoO0 N
3AI~IO /V%3~O-IC
SITE PLAN
SCALE 1" = 50'
NORTH 220'OF THE WEST 396' OF NWl/4 SWl/4
NWll4, SECTION 35, T12N, R3W
DESIGN FACTORS:
Four Bedroom Home
Perc. Rate: 2-4 Min./Inch
Avg. Application Rate: 1.2 GPD/SF
SYSTEM REQUIREMENTS:
Deep Trench System
1,250 Gallon Septic Tank
8' Drain Field Rock
4 Bedrooms X 150 GPD / 1.2 GPD/SF = 500 SF of Absorption Area
500 SF/16 SF/LF = 31.25 LF Trench Length
Therefore: Construct an Absorption Trench 35' in Length by 3' Wide With 8' of Drainfield
Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 2' Below Existing
Ground. Total Depth of Trench to Be 10' Below Existing Surface. Cover Over Septic Tank
a Minimum of 4' or 2" of Insulation and 2' of Cover
NOTE:
Natural
Backfill
Geotextile
Fabric
4" Perforated
PVC (Sched~Ie 40)
Drainfield Rock
TYPICAL DEEP TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 10' From Lot Line.
Minimum 4' Separation From Groundwater.
Minimum 100' Separation From Wells in the Area.
Minimum 10' Separation From Water Service Line.
Municipality of Anchorage
Building Safety Division/On-Site Water and Wastewater Program
4700 South Bragaw Street, Anchorage, AK 99519
SOILS LOG - PERCOLATION TEST
Performed For: ,John Warner
Legal Description: North 220' of West 396' S35, T12N. R3W
SLOPE
OG/OL
5
6
7
8
9
10
ii
12
13
14
15
16
17
SW
Golden
TESTHOLENO. 1
Well Graded
Sands
with
Gravel
Gray/Loose
., r Some Silt
Bottom of
Hole
Was Groundwater
Encountered? No
If Yes, What Depth?
Depth to Water
After Monitoring None
Date: 9i4i02
Date Performed:
SITE PLAN
See Site Plan
Reading Date Gross Net Depth To Net
Time Time Water Drop
1 3-Sep 2:00 1,25
2 2:10 10 6 4.75
3 2:11 1.25
4 2:21 10 5.5 4.25
5 2:22 1.25
6 2:32 10 5:5 4.25
7 2:33 1.25
8 2:43 10 5.5 4.25
18
21
Perc. Rate: 2.5 Min./Inch Perc. Hole Diameter: 6"
Test Run Between 4.5 Ft. and 5.5 Ft.
Comments: Perc Cavity Presoaked Prior to Test.
Performed By: MEA. I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 914102
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: N 220' OF THE W 396' NWl/4 SWl/4 NWl/4 SECTION 35
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250-gallon septic tank at the location shown on the site plan
and the construction of a 35' long by 3' wide by 8' effective depth
absorption trench also shown on the Site Plan. The total depth of the
trench will be 10' below existing ground and the distribution pipe will be
placed at 2' below the surface. 2" of Insulation must be placed over
the service line and under the driveway from the house to the septic
tank. All components of the septic tank and absorption trench must be
constructed a minimum of 100' from the well on the lot. A minimum of
4' of fill must be placed atop the septic tank and 3' of fill above the
absorption trench. In lieu of fill 2" of direct bury insulation may be
placed with 2' of fill atop the insulation. The existing absorption crib on
the lot must be pumped, crushed and backfilled.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with any special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final 9fading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
pdor approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. The 1,250-gallon septic tank must be procured from an approved
septic tank manufacturer and installed at the location shown.
A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
N 220' of W 396' Section 35
September 4, 2002
Page 2 of 2
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct
budal insulation.
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
o
Distribution piping must be placed level with perorations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
o
Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
[JI t~,Vt~nt b~LLl~l I tUI IL
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the reck. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
N 220' of W 396' Section 35
September 4, 2002
Page 3 of 3
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must.be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted Under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabric, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.
Certified Well
Date complet ed....~M.~2~....~. ~.~.~. ......................................................................
Oev~h o~ wen_.__RS.F.¢:¢.~. ............................... : ..................................................................
Size of 'casihg..._.~.._.~.Q~ ...................................................................................................
~istance to water while pumpin~
of .................. ~. .............................. ~allons ~er honr. '
Description of' Formation ~ ~" from
to
~5
~5
?0
73
95
I certify, the above true and correct.
............ ~ ............................................. L_LA ......................
Driller
FOSS DRILLING
1336 INGRA PH. 279-2849
ANCHORAGE, ALASKA 99591
We advise you to attach this certificate to your deed.