HomeMy WebLinkAboutGREAT LAND ESTATES #3 BLK 2 LT 12reatland
Ester.es
Block
Lot :1.2
#051-133-14
Municipality of Anchorage ..:;~ :~.~.
Development Sen/ices Department .:~ -.
Bu~ldlng Safety DMslon
On-Site Water and Wastewater Ptcgram. 4700 S. Bragaw SL '~ L~'
P.O. Box 196650/mchorage, AK 995196650 Page J of
vn~w. ci. anchorage,ak, us (907) 343-7S04
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number:
17 7,5'7/'/~J(9-P' .~,., v~ ,~9[C ~0~,¥~.,# # ~577 ABSORPTION FIELD
Well: ~New
Y~eld: ~ I Pump ~a~ ~ ~s~ ~ ~e~
o~,1 ~nE~ ~I ~ ~ TANK
SEPARATION DISTANCES ~e~ ~ Holding D S.T.E.P. ~ Othe~
Tank FieM Sta~on Tank S~er ~e Gal.
~,,J~0' 115' ~ ~ ;5~''~'~ N~P~ ,
"'~"~': BENCH MARK
. Engi~.
S & S ENGINEERING
,,'~; ~..~,~
Development Se~ces Depadment Approval
Reviewed and approved by:
PERMIT NO. SW020217 PACE 2 OF 5
_. Mun. O. ic:ipg_ti~y._o.F .A.n_ch.o..r-gg.e.
DEPAR'I'M~Nm uP HJsAL/H AND HUMAN SERVICES
ENVIRONHENTAL SERVICES DIVISION
P.B. Box ].96650 e,_Anchor'oge, Ato. sko. 99519-6650 · Telephone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEH AND/OR WELL INSPECTION REPORT
LgCAL LOT 12, B.L.O.CK 2~ GREAT LAND ESTATES #5 P.I.D. NO. 051--15.5-14
I
FlEW 1300 GALLON
HOP[ SEPTIC 1ANK-~
CG2~,~4T 1 TM~
~~/ ~ ~'~'-~-,~ ..... =,..,.~
PERMIT NO.SW020217 PACE 5 OF 5
Municip. o, tit: oF .A.n c h.o, .r' g 9.e'
DEPARTMENT OF HEA~TH ANt.) HUMAN SERVICES
ENVIRONMENTAL SERVICES DIVISION
P.B. Box 196650 ·Anchoroge, Ato. sko. 99519-6650·TeLephone: 343-4744
ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
LEOAL LOT 12, BLOCK 2, GREAT LAND ESTATES #5 P.I.D. NO. 051-133-14
ST1 ST2 ~- 98.5'
FINAL GRADE-/ 2" INSULATION
93. 3.2'
A B
rco 8.5' 36.0'
C03 32t5' 35.5'
ST1 38.0' 32.5'
ST2 40.5' 31.0'
I'MT 42.5' 34.5'
DBL1 47.0' 26,0'
DBL2 48.0' 25.0'
C01 *37,0' 16.0'
MT1 63.0' 49.5'
C02 65.0' 50.5'
FINAL GRADE/ ..... ~ .......... ~../2" INSULATION
C02=91.3'
* USES POINT C
·
NO WATER FOUND
80.0' B.O.H.
N. ?. -q.
~ ~-~ 99.~ "
· . :.~'..~..
Permit Number ~u.lOZo21.7 Date Of I~sue ~9 ~ 0 ~ Parcel Identification Nu~ber,~/.-~- ~ ~
Date~ta,ed __ Da~Completed ~-/~-O~ I~weUIo~atedatapprovedpermJtlocation? ~Yes ~ No
Legal Description Block Lot Property Owner Name & Address:
Bomhole Data: Depth Method Of Drilling: ~ air rota~ D ~ble tool
Soil Type & Thickness & Water Strata From
Casing Type: ~ Wall Thickness~in~es
~ ~.~ O O B Di~meter~ Inches, Uepth ~ feet
· Liner Type: Diameter Inches, depth feet
Static Water Level (from ground levol): /~.~ feet
~a[~.~ & ~g~O~ ZO '/0~ PumpingLevel: feetaaer hrs. pumping qpm
Recove~ Rate:
~( ~ Welllntake Opening Type: ~Open End D Open Hole
~ /0~' j/~ ~ Screened; Sta~ feet Stopped feet
D Pedomtions Sta~ feet Stopped. feet
' ~ GreutType: ~/f~ Volume
~J _~ ~Od p~ ~ ~O Depth; from -0 feet. to ~0 feet
~ Pump Intnke Depth: feet
~0~1 ~ ~O ~y~ PumpSize. hp Brand Name
' -- Well Disinfe~ed Upon Completion? ~Yes 0 No
Method Of Disinfection:.
Attention: The well driller shall provide a well Icg to the property owner within 30 days of completion
and the property owner or the well drilIer shall provide a well Icg to the Dept. of Health & Human
Services within 60 days of completion.
dOO:~O CO ti qa~
I'll]ERr C. coWAH. P.E.
I"tOB ER1' A. SItAFER, P.E.
CIVIL ENGIHEEr~
Da~et
(907) 694-29'/9
FAX (907) 694-12
IEN. IIIAUTI IOfaTY
SEwTR&wmER
MA,~I E~IEt,~lOt,~
,SE'~R &WAIEFI
~LL It,~PECt'IOI4
FLOW 1EST
FIOAD ~SIGN
SO~.IEST
I'~nCOLAIION
L~O tA~,qCAt.
t4sr, Ectt(~,ls
Municipality of Anchorage
DEPARTMENT OF IIEALTll AND ItUHAN SERVICES
825 L Street
P.O. Box 196650
Anchoraget Alaska 99519-6650
The septic inspections for the referenced property were
performed on7-30-~ and 7-~/--d~ · Prior to submitting
the On-sAte Wastewater Disposal System and~o~We!l Inspection
Report we are waiting for tile ~k/~n/~5-bu;/~ to be
completed. "~y
If we may be of further service, please contact us.
Sincerely,
~2ber C~ Cowan, ~
17034 NORTI I EAGLE RIVER LOOP t, SUIIE 204 · EAGLE ntvEn. ALASKA 99577
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT
Initial
Date Issued: Jul 09, 2002
Expiration Date: Jul 09, 2003
Permit Number: SW020217
Legal Description: GREAT LAND ESTATES #3 BLK 2 LT 12
Design Engineer: 0003 S & S Engineering
Owner Name: Dennis McCormick
Owner Address: 17757 Chilkat Ct.
Eagle River, AK 99577-
Parcel ID: 051-133-14
Site Address:
Lot Size: 93218 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
[] Disposal Field [] Septic Tank [] Holding Tank [] Privy
[] Private Well [] Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
7/ o/oz ro
Received By:
Issued By:
Date: '~/~/~'
Date: ~
DeVelopl-neht Services bepartrnetlt
bultding Sably Dlvtsion
On-Site Waier and Was~ewa[er Program
4700 Soulh bragaw st.
P.o. Box ~96650 Anchorage, Al< 995~9-6650
w,,wv.ct.anchoi'age.ak.us
{907) 343-790,{
ON-SITE SEWER/WELL'PERMIT APPLICATION
FoP, A SINGLE FAMILY DWELLING
Parcel I.D.
Permit Number .SW O Z O Z ! 7
Property oWner(s)
Mailing address (1)
Mailing address (2)
Legal description (Lot, Block & SUb'&)
Legal description (Section, ToWnship & Range)
THIS APPLIcATIoN IS FOR:
Sewer Only []
SeWer and Well
Sewer Upgrade
THIs PROPERTY CONTAINs:
HotTulo []
Swimming Pool []~
l'herapy Pool
Number of Bedrooms
Well Only []
Water Storage []
Jacuzzi []
Water Softening Unit []
I certify that the above Information is correcL I {ur{her certify that thts application is being made for a
Sift§la l~amily bwellln§ and Is In accordance with applicable MUnlclpat Codes,
(Signature of property owner or aulhorlzed agent) 17034 E~gle River Loop Road, No. 2~
Eagle River, Alaska 995~
Parrot{ Fees:
bale of Payment: "7 /
Recelp~ Humber:
(Rev, '12/00)
,lvei' ~=ees:
Date ot I~aymenl:
~eci~Ipt Humber:
July g, 2002
ROBERT C. COWANo P.E.
CML ENGINEERS
(907) 694-2979
FAX (907) 694-'1211
SEWER&WATER
IdAIN EXTENSIONS
SEWER&WATER
INSPECTION
E. NG~NEERING STt. IOIE$
ANO ~PORT$
WELLINSPEC'nON
*-R. OW'TEST
~TION
TEST
STW, JCTU~N. &
IV~CHN',nc, N.
~PEC:TIONS
WA~ TEWAT ~'R
MUNICIPALITY OF ANCHORAGE
Dev, elopment Services Department
P.O. Box 196650
Anchorage, AK. 99519
REFERENCE: Lot 12, Block 2, Great Land Estates S/D ~n3
It is requested that you issue a permit to install a well & septic system to serve the
proposed one & three bedroom dwellings on the referenced properly. However, thc
dwellings will not be served simultaneously. The septic system is sized for four
bedrooms, even though only a three bedroom design is required.
A test hole was excavated and a percolation test was performed. The approximate location
of the test hole is located on the attached site plan. At the time of excavation on 6/15/02 no
water was found. After seven days of ground ~vater monitoring the test hole was still found
to be dry.
The garage with a single bedroom apartment will be built at this time. The proposed three
bedroom house will be completed in approximately three to five years. The area over the
garage will no longer be used as a dwelling unit upon completion of the three bedroom
house.
We do not anticipate any adverse effects on neighboring wells, septic systems, reserve
areas or drainage patterns by the installation of the proposed septic system. The
construction of this system will not prevent any future development on any of the adjacent
properties.
If you require additional information, please contact us.
Sincerely,
Robert C. Cowan, P.E.
RCC/jhm
Enclosure
17034 NORTH EAGLE RIVER LOOP * SUITE 204 4 EAGLE RIVER. ALASKA 99677
~': LOT 12, BLOCK 2, GREAT LAND ESTATES S/D -~.5 ! ~~-'~ !
DESIGN CRITERIA: s~.ucTu.gs, raIMENTS. OR [NCR~HMENTS
4
BDRM
600
GPD
SOILS = 1.2 GPD/SQ.FT. ~ ~-BU~LT SU~[Y D~WN BY:
600/1.2 : 500 ~O.FT. REQ'D. WILLIAM D. FLEMING
TRENCH CRITERIA: ,o vi.,. m[u[..s..[ou,.[*
8' DEEP CO~SmUCT~ON.
I
5' EFFECTIVE I '~'[SS~' ~ I
50' kO~G
CONT~TOR IS REQUIRED IQ
PRIOR TO ~Y [X~VATJON
wORK.
! 2
3
13
ALL PORTIONS OF SYSTEM
WITH LESS THAN 5.5' OF
COVER REQUIRE INSULATION.
It
Io
1o
LJ
J.H,M. R.C.C. 7-8-02 2 OF 2
DESIGN CRITERIA: STRUCTURES. U~E.E.,S. OR
t~r~lt~ 4 BERM : 600 OPE SHOWN ON THIS SITE PLAN ARE ~ SHOWN ON
SOILS : 1.2 GPD/SQ.FT. , N~ ~S-BU~LT SURVEY OP. AWN I~¥: .
W~LUAM O. F'EM~NC ;~_.
TRENCH CRITERIA: TO VER,~ U~E~.,S.
FAX# (907)694-1211 50' LONG '~."o. --z
o CONTRACTOR IS REOUtR[D TO
z OBTAIN UTlU'h' LOC. ArES
PRIOR TO ANY £XCAVA~'iON
WORK.
'O PROPOSED 1300 GALLON
'~. .,,HDPE SEPTIC TANK'--~
WITHIN 100'+
. _ ~~~~,,'~ ! ~,"./ ,~,.
PROPOSED ~ BD~M "~'~E.~H /'~7 12 7,,.'~-/
HOUSE TO BE BUILT /q<,.'ox,,'. ( INSTALL-'~ ' 1~
- & CONNECTED TO / "<:ZO,~\ DOUBLE Ih-' /~,~
'< SEPTIC SYSTEM AT / ~".~.¢N,CLEANOUTS _-:',/~ /:'" / \
."'I ~%X~1 /._~/ \
J' .COVER REQUIRE 'INSULATION.X C.,'~,
Municipality of Anchorage
Development Services Department IfJ'/'
Building Safe~ Division ir~/ ~k
On-SiteWater and Waslewatar Program J,.-,-.'~'~~';''"'~
4700 sou,, ,ragaw St I.~'-///Z.Z..,~ ~:
P.O. BOX 196650 Anchorage, AK 99519-6650 ~"--11~'~
Soils Log - Percolation Test
/
SI°p~ Site Plan
5-
6-
7-
8-
9-
10-
11-
12-
IF YES, AT WHAT DEPTH?
Dele: ~.~Z~
13-
14-
15-
16-
17-
18-
19-
20-
COMMENTS
Reading Dale Gross Time Net Time Depth Io Water Net Drop
lo '/+"
PERCOLATIOt'! RATE ~ :.~nute~ncrq PERC tlOLE DIAkIETER (
TEST RUN BETWEEt,I ~" FT .ID ~ FT
PERFORMED BY: f ~.--I,.-!~ ~ CERTIFY THAT THIS TEST WAS
PERFORMED IH ACC'ORI~NCE W~TH ALL STATE AND MUNICIPAL~UIDELINES IN EI~F-ECT ON THiS DATE. DATE: C/3-~q'/O Z.
ROBERT C. COWAN. P.E.
CMl ENGINEERS
(907) 694-2979
FAX (907) 694-1211
SEWER&WATER
MAIN EXTENSIONS
SEWER&WATER
INSPECTION
ENG~NEF~IING STUO~S
ATtO P~PORTS
WEU. INSPECTION
& FlOW TEST
SrTE F%ANS
ROAD DES{GN
SO~.TEST
PEI~X~.ATION
TEST
STaUCm~. &
INSPECTIONS
SITE
WASTEWATER
I~oC~JU. $~TEM
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION PRACTICES
and
MATERIAL SPECIFICATIONS
.REFERENCE: Lot 12, Block 2, Great Land Estates S/D ~ J
July 3, 2002
GENERAL:
The scope of this project includes the installation of a 1300 gallon HDPE
septic tank and a new trench to serve the proposed one bedroom & proposed
three bedroom residences located on the referenced property. The three
bedroom house will be connected at a later date.
Construction shall be in accordance with the approved site plan and design
drawings, Municipal permit with any special provisions or conditior/s, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. . The contractor shall be responsible for obtaining any necessary underground
utility locates.
Unless specifically agreed otherwise, the property o~vner shall be responsible
for final grading areas subsequently depressed from soil settling.
Contractors installing wastewater disposal systems must be certified by the
Municipal Health Department for system installations. Owners installing their
own systems must also receive prior approval from the Municipal Health
Department.
SEPTIC TANK INSTALLATION:
A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
t7034 JqOFTTH EAGLE RIVER LOOP; SUITE 204; EAGLE RIVEF~ ALASKA 99577
Page 2
Lot '12, Block 2, Great Land E.tatas $/D ~ ~
July 3, 2002
All standpipes on the septic tank shall extend a minimum of 12 inches above final grade.
Septic tanks installed with less than 4 fl. of cover shall be insulated.
A foundation cleanout shall be installed one to four feet from the building foundation. In
the line between the tank and the leachfield there shall be two adjacent cleanouts (unless
an effluent pumping system exists within the septic tank). These cleanouts shall be
located on undisturbed soil not mom than 10 ft. from the tank. The first cleanont, in line,
shall be to clean toward the leachfield. The second cleanout shall be to clean toward the
septic tank.
Final grading over the septic tank shall be such that a positive slope exists away from the
septic tank.
ABSORPTION TRENCH/DRAINFIELD INSTALLATION:
Excavate the proposed trench to the dimensions shown on the design. The bottom of the
excavation shall be within 2 inches of level. If the sidewalls of the excavation become
smeared, they must be raked or scratched (ruffed-up) before gravel (sewer rock)
placement.
Once the gravel is installed, the distribution pipe is to be installed level with the
perforations faced downward. Gravel is then to be placed over the distribution pipe to
provide a minimum of 2 inches of cover over the pipe.
A silt barrier must be installed between the final gravel layer and the native soil backfill.
Ensure the silt barrier covers the entire gravel surface before placing backfill.
Monitor tubes shall be of four (4) inch diameter, installed approximately in the locations
shown on the design, and extend a minimum of 12 inches above final grade. The portion
of the monitoring tube extending through the gravel shall be perforated from the bottom of
the trench to the invert of the distribution pipe. This is equivalent to the effective depth of
the gravel as noted on the design.
Backfill over the final gravel layer must not be less than twenty-four (24) inches.
Insulation must be installed when the backfill depth is less than thirty-six (36) inches. The
finish grade over the trench must be mounded to prevent the formation of a depression
after settling.
Page 3
Lot 12, Block 2, Great Land Estates $/D
July 3, 2002
MINIMUM MATERIAL SPECIFICATIONS:
Any septic tank proposed for installation must bc constructed by a Municipal approved
septic tank manufacturer.
The following pipe materials are approved for use in septic system installations in the
Municipality of Anchorage:
Type of Pipe Perforated Solid
Cast Iron Yes Yes
ASTM D3034 (PVC) Yes Yes
ASTM F810 (HDPE) Yes No
ASTM D2662 (ABS) Yes Yes
Use of a type of pipe other than listed above must be approved by the inspecting engineer.
Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical
Company Styrofoam HI or equal).
Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or
equal).
A pe,lneable nontoxic silt baffler (Typar 3401, Mirafi 140N, or equal) must be installed
between the final leachfield gravel layer and the native soil backfill.
All leachfield gravel (sewer rock) shall be 0.5"-2.5" screened gravel with less than 3%
passing the #200 sieve.
When sand is being used as a filter material, its gradation specifications must conform to
current M.O.A. or D.E.C. requirements, which ever requirement applies.
INSPECTIONS:
Typically there will be a minimum of three (3) inspections required during the installation of the
wastewater disposal system. These inspections will occur as follows:
Page 4
Lot 12, Block 2, Great Land Estates $/D ~ ~
July 3, 2002
The first inspection must be conducted after the excavation of ditches, pits,
trenches, or beds and before the installation of any gravel. A septic tank may be
set in place, but may not be backfilled before this inspection.
The second inspection must be conducted after the placement of the silt barrier,
gravel, distribution lines, standpipes, cleanouts, and insulation, but before the
placement of any other backfill.
3. The final inspection is to occur upon final grading ofthe property.
Often there will be more than these 3 inspections required. Especially with the installation of
multiple trenches, sand filters, pressurized distribution systems, etc. Thus, the inspecting engineer
is to be contacted at least 24 hours prior to the start of construction. If necessary, a pre-
construction meeting will take place on-site. The inspecting engineer will not coordinate, direct or
control in any way the contractors activities.
The owner shall contract with the contractor to perfom~ the work outlined in these specifications
and plans and in accordance with the attached M.O.A. permit. There will be no contractual
arrangement existing between the contractor and S & S Engineering. S & S Engineering shall be
the owner's representative and will inspect the work as stated above to document the contractors
activities. Final acceptance of the contractors work rests with the owner and the M.O.A.
S & S Engineering shall have no liability to the owner or to others for acts or omissions of the
contractor or any other persons performing work on this project or the failure of the contractor to
carry out the work in accordance with these construction documents. S & S Engineering's
inspecting engineer will not be responsible for the construction means, methods, techniques,
sequence, procedures or the safety precautions incident to this project.
CONTRACTOR / INSTALLER
JUt.-2fS-200~ 12:00 S&S L~qGII~r.~I~IG 907 69.~ 1211
July 25, 2002
Reference: Lot 12; Block 2; Greafland Estates S/D
Subject: Owner Installation of Prlvate Septic System
To Whom It May Concern,
I am thc owner of referenced lot and will bc installing thc septic system on the lot.
I am familiar with and have experience with the operation of the required ~quipmcnt and
the installation of septic systems.
I will bc inst~ll~ng the septic system in accordance with the design done by S & S
Engineering, and will have S & S Engineering doing all required inspections and
documentation.
Dennis McCormick
Cell 229-2723
TOTFL P. 02