HomeMy WebLinkAboutKNIK VIEW ESTATES BLK 5 LT 13Knik Vi W Estates Block 5 Lot [ #051-043-53 · ' Municipality of Anchorage Page 1 of 3 Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907) $43-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW020304 PID Number: 053.-043-53 Na~: MM&M Contracting WastewaterSystem: New Adckess: P.O. Box 670495 Chugiak, AK 99567 ABSORPTION FIELD Ph~le: Number o! Bedroems: 688-3.236 Four (4) s' Wide Trench Soil Rating: Total Depth from ~igthal grade: LEGAL DESCRIPTION 1.2 *,D~' 8.0 Block; Lot: Subdivisi~ Depth to pipe bottom from original grade: Gcavel depth beneath pipe: 5 3.3 Knik View Estates 4.0 ,,. 4 Tow~shlp: Range:, Secti(~: Fill added above original grade: Gravel Length: 0 ~,. 51 ~,. Well: Community Water System 5 r,. 3. - A n. ~, 53.0 ~t' ASTM D3034 PVC ,, MM&M Contracting 8/30-9/4/02 ~,M ,,. ~, TANK S EPAR~TION'DISTANCES Septic From'~ Septic Absorption . Lift Holding ~ublic/Pflvate I.'~nufac~ec Capec~ty in Gallons: Tank Field Station Tank S~,~rU,. Anchorage Tank 3.,250 w,, >200' >200' N/A N/A >25' Steel Two (2) ,ot,~.s~'~' Wa,,, >3.00'>5, >3.00'>3.0, N/AN/A N/AN/A ~ s,,.: o.,. ~.~u,.~.LIFT STATION Fo~,~. >5' >3.0' N/A N/A '"""P ~"'~'''': '"~ ~"'~''': I "~¢'"'" cu~.orai. None Noted ,.~..&.o~, "'"~': BENCH MARK Finished Floor. 100.0 F~ Engineer's Stamp ~\~ ........... .':,.,q ~-, · ~.~.... ...~e. · .' ~..'.;.' ,t Inspections performed by: Tim Kimbrough Dates: 1't 8/30/02 l~tl--";t:""'""w' - '*r'~:~.....~, _ 2"" 9/4/02 ~ ~ ~";;~;;;~["[.";:.0,,,o. Department of Health and Human Services approval ~,?..^~.:..... __,o. ct-,~,, '**~o ~-: ......... Reviewed and approved by: Date: STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION 555 Cordova St., Anchorage, Alaska 99501 On-Site Wastewater Disposal System or Well Inspection Report Permit Number: SW020304 TBM = 100,00 8,3' 92.77' 2.68' 1250 Gcd. ton ~ep'tlc Tank / 4,5 Page 3 of 3 PID No. 051-043-53 96.34' PROFILE AS-BUILT Scale: 1' = 10' Municipality of Anchorage Development Services Department Page 2 of 3 Building Safety Division On-Site Water and Wastewater Program On-Site Wastewater Disposal System and/or Well Inspection Report Permit No, SW020332 PID No, 051-043-52 1'3 C5 Site Bedroom Home A I~ S1 119.2123.6 S2 1 23.1J 27.9 C4 1 50.0126.7 cs127.7166.6 FROM : QI.INTRY REALTY PHON~NO, : 90?6881238 F~b. 0~ ~ 09:06AH Pi AS-BUILT ~e R~ing P~nct, Absk~ and t~at the i~'~v~ . P q Y, ~e(~6~ '.". .., MUNICIPALITY OF ANCHORA GE Devetoprnent Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Aug 19, 2002 Expiration Date: Aug 19, 2003 Permit Number: SW020304 Legal Description: KNIK VIEW ESTATES BLK 5 LT 13 Design Engineer: 0014 Anderson Engineering Owner Name: MM&M Contracting Owner Address: PO Box 670495 Chugiak, AK 99567- Parcel ID: 051-043-53 Site Address: Lot Size: 22052 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 This permit is for the construction of: [] Disposal Field [] SepticTank [] Holding Tank [] Privy. r-~ Private Well ~ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. Ail requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: ^. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Issued By: Date: Date: Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Permit Number .SWOZ Property owner(s) MM&M Contractinq, Inc. Mailing address (1) P.O. Box 670495 Chu,qiak, AK 99567 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 13, Block 5, Knik View Estates Subdivision Legal description (Section, Township & Range) Lot Size ~,.,~L_~.~'.~.._ Acres/~.".~ Number of Bedrooms Four (4) Day phone 688.1236 THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool [] Well Only [] [] Water Storage [] [] Jacuzzi [] [] Water Softening Unit [] [] I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: (C.~, Receipt Number: o~¢ l ~"~ ~ (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 . 522-7773 522-6779 (FAX) August15,2002 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 13, Block 5, Knik View Estates Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 13, Block 5, Knik View Estates Subdivision intends to construct a four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new and alternate septic system and the parameters used in the design. Also identified on the plans is the test hole location and the locations of the existing systems on adjacent lots. The subdivision is served by a Class A water system and the approximate locations of the water service lines are shown. Drainage arrows are also shown and current drainage patterns will be maintained after construction. The test holes placed near the location of the proposed and alternate absorption trenches indicated well to poorly graded sand with gravel and varying amounts of silt and a percolation rate of between 1 and 2 minutes per inch. No groundwater was found during the excavation and none was noted dudng the ensuing monitoring pedod. We are therefore proposing to construct a 5' wide absorption trench system with 4' of drainfield rock beneath the distribution pipe. That pipe will be placed at 3.5' below the surface with a total depth of 7.5'. The total length of the trench will be 50'. The ground surface on the lot slopes as shown on the attached Site Plan with fairly shallow to no slope in the area of the new absorption trench. The new septic tank and absorption trenches will be constructed in a fairly shallow surface slope area behind the proposed house in conformance with Municipal requirements and parallel to ground contours where possible. All components of the new trench will be constructed a minimum of 200' from the well serving the community water system, The system will also be constructed a minimum of 100' from any surface water in the area and 10' from the water service line. If the system is constructed in accordance with our design the following statements apply: L~)[ 13, Block 5, Knik View Estates August 15, 2002 Page Two ]. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments 17 19 4 3 14 15 15 16 AREA SYS_~_TEM PLAN SCALE 1" = 100' 49th S89', ;O Fou~ Hedroom House 'LOT 13, BLOCK 5, ~ KNIKVIEW ESTATES /. / 50' Long X 5' Wide. X 4' Effective Deptl~ · Absorption TrenchI ,250 Gallon Septic Tank SITE PLAN SCALE 1" = 30' LOT 13, BLOCK 5, KNIK VIEW ESTATES SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: 4 Bedroom House Perc. Rate: LT 1 Min./Inch Application Rate: 1.2 GPD/SF 5' Wide Trench System 1,250 Gallon Septic Tank 4' Drainfield Rock 4 Bedrooms X 150 GPDI1.2 GPD/SF (Application Rate) = 500 SF of Absorption Area 500 SFI5 LF (Width)* .5(Red. Factor) = 50 LF Trench Length Therefore: Construct a 5' Wide Absorption Trench With a Total Length of 50'. Flowline Elevation in Trench to be 9' Below Original Ground Surface. Total Depth to be 3.5' Below Existing Ground. Total Depth to be 7.5'. Maintain 10' Separation From Water Service Line. 6I! Natural Backfill 4 '0" ~ Geotextile Fabric 4" Perforated PVC (ASTM 3034) Drainfield Rock ,5'0" .I I NOTE: TYPICAL WIDE TRENCH SECTION Grade Area Over Trench to Drain Away. Minimum 6' Separation From B~rock. ~.-~-'~['-~~--.~ ...................... Minimum 4' Separation From Groundwater. ~r . _......... } Minimum 100' From Wells in the Area. ~~- ~.~ ~' Minimum 10' Separation From Water So.ice Line. ~.. **~>.... .~..'"~F ~'~ '~'"'"~'~x~ PROJECT #: PERFORMED FOR: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0505 SOILS LOG - PERCOLATION TEST M0238 PAUL HYERS / HM&H CONSTRUCTION LEGAL DESCRIPTION: LOT 13. BLOCK 5. KNIK VIEW SUBDIVISION DATE PERFORMED: 8/2/02 I 3I '5 6-- 7-- 8-- 18 COMMENTS: TEST HOLE -fi: OB I OO SLIGHTLY DENSE WELL GRADED SANDY-GRAVELS: OW TH .1 SLOPE OX SITE PLAN TN 2 0 TH1 O WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTH? DEPTH OF WATER *,~" TE R MONITORING: DATE: NO S L 0 P E o% GROSS NET DEPTH OF NET READING DATE TIME TIME WATER DROP Starl 8/2/2002 10 05 12" 1 10.15 10 2" 10" Recharge 10.15 12" 2 10.25 10 2" 10" Recharge 10 25 12" 3 10,35 10 2" 10" PERC RATE: 1 MIN./INOI PERC. HOLE DIAMETER: 6" TEST RUN BETWEEN 3 5 FT. AND /..5 FT. NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST TEST PERFORMED BY: T.L. KIMBROUGH I, MICHAEl F. ANDFRSON, CERTIFY THAT TH~S TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: ;~) -J~'--O~.~ PROJECT #: PERFORMED FOR: MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & HUMAN SERVICES 825 L STREET, ANCHORAGE, AK 99502-0605 SOILS LOG - PERCOLATION TEST M0238 PAUL MYERS / MM&M CONSTRUCTION LEGAL DESCRIPTION: LOT 13. BLOCK 5. KNIK VIEW SUBDIVISION DATE PERFORMED: 8/2/02 I 3-- 5-- 6-- 7-- 8-- 9-- 18 COMMENTS: TEST HOLE # TH #2 SLOPE OB / OO SLIGHTLY DENSE WELL GRADED SANDY-GRAVELS: GW 0% SITE PLAN TH 2 O TH 1 O WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTtt~' DEPTH OF WATER AFTER MONiTORiNG: DATE: NO S L 0% READING DATE GROSS NET DEPTH OF NET TIME TIME WATER DROP Start 8/2/2002 1040 12' 1 1020 10 2" 10" Recharge 10:20 12' 2 1030 I0 2" 10" Recharge 10:30 12" 3 10 ~,0 10 2~ 10" PERC RATE: 1 MIN./INCH PERC. HOLE DIAMETER: 6' TEST RUN BETWEEN. 3 S FT. AND ~, 5 FT. NO IMPERMEABLES ENCOUNTERED / HOLE PRESOAKED PRIOR TO TEST TEST PERFORMED BY: T.I.. K~MBROUGH I, MICHAFL E. ANDERSON, CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: ~ -/5"'- ~Z.,. ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 13, BLOCK 5, KNIK VIEW ESTATES SUBDIVISION GENERAL: The scope of this project includes the procurement and placement of a new 1,250 gallon septic tank at the location shown on the site plan and the construction of a 50' long by 5' wide by 4' effective depth absorption trench also shown on the Site Plan. The total depth of the trench will be 7.5' below existing ground and the distribution pipe will be placed at 3.5' below the surface. All components of the septic tank and absorption trench must be constructed a minimum of 10' from the water service line on this lot. A minimum of 4' of fill must be placed atop the septic tank and 3' of fill atop the absorption trench. In lieu of fill 2" of direct bury insulation may be placed with 2' of fill atop the insulation. Construction shall be in accordance with the approve~l site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive pdor approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION The 1,250-gallon septic tank must be procured from an approved septic tank manufacturer and installed at the location shown. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. Lot 13, Block 5, Knik View Estates August 15, 2002 Page 2 of 2 A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfleld. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfleld rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall vedfy this condition pdor to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). Lot 13, Block 5, Knik View Estates August 15, 2002 Page 3 of 3 o A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. Ail drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 Parcel I.D. 1, CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING o51-o43-53 GENERAL INFORMATION Complete legal description Location (site address) Expiration Date: Lot 13, Block 5, Knik View Estates 22500 Judd Drive Chugiak, Alaska 99567 · Current Property owner(s).. Bruce & Theresa Scanes Mailing address PO Box 671813 Chugiak, Lending agency Day phone (907) 688-6256 Alaska 99567 Day phone Mailing address Rea.i.E§~t~'A~nt~., Barb Huntiey/Prudentiai Day phone(907) 273-7377 5'~Mailing,Address.,~:;- 3801 Centerpoint Dr, Suite 200 Anchorage, AK 99503 Otl~erwise'fequ~s}~d; ~------ ~"' COSA will be held by DSD for pickup. TYPE OF WASTEWATER DISPOSAL: 2.- NUMBEROF:BEDROOMS: 3. TYPEoF wA~ER SUPPLy: Individual Well [] Individual Water Storage [] Community Class A Well [] Public Water System [] Individual On-site Individual Holding Tank Community On-site Public Sewer The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a pUblic water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Pinar4 Address PO Box Engineer's Printed Name Engineering 871347 Wasiiia, Alaska Paul E. Pinard~ P.E. Phone (907) 357-3647 99687 Se DSD SIGNATURE ' \/ Approved for Disapproved. Conditional approval for bedrooms. bedrooms, with the following stipulations: WATER AND ~/ASTEWATER : ~ ' ' ~ ...... ee · ~ Attachments: COSA Checklist X Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ~L''~- ./~--// (Rev. 11/05) Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www. muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Block ~, Knik View Estates IfA, B, or C provide PWSID # 21 8409 Sanitary seal (Y/N) ..... Cased to ft. FROM WELL LOG ft. g.p.m. Legal Description: LoS 1 ]~, A. WELL DATA Well type A Date completed ~ Total depth ft. 2 Depression over tank (Y/N)I~o Pumper JRs Puml3in{~ Date of~test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies/100 mL Nitrate ~ mg/L Arsenic: ug/L date of sample: B; SEPTIC/HOLDING TANK DATA Tank Type/Material Sept'ic/Stee'i Tank size 1 2,50 gal. Number of,Compartments Foundation cleanout (Y/N) Yes Date' of pumping .9/2/+/10 C, ABSORPTION FIELD DATA Parcel ID: 0;51-0/+3-5_3 Well Log (Y/N) Wires properly protected (Y/N) casing height (above ground) AT INSPECTION in. g.p.m. Other bacteria Collected by: ~colonies/100 mL Date installed 8/30 - 9/4/02 Cleanouts (Y/N) High water alarm (Y/N) Date installed 9/02 Length 51 ft. Total depth 8 ft. Eft. absorption, area :51 0 ft2 Date of adequacy test 5/2/11 Fluid depth in absorption field before test -34 in. Elapsed Time:200 min. Final fluid depth .3/+ Any rejuvenation treatment (past 12 mo.) (Y/N & type) Soil rating (g.p.d.;~t~~ 1.2 System type 5 W'ide Trench Width 5 ft. Gravel below pipe /+ ft. None Monitoring tubeYes Depression over field' No Results (Pass/Fail) Pass For /+ bedrooms Water added 6-30gal. New depth-38 in. ~ in. Absorption rate >= 600+ g.p.d. ][noun If yes, give date D. LIFT STATION NA Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at ~ in. ~Pump off" level at ~ in. High water alarm level at Datum Cycles tested Meets alarm & circuit requirements? E. SEPARATIONDISTANCES NA - PUBLIC 1~ATER SYSTEt4 - NO WELL ON LOT SEPARATION DISTANCES FROM WELL ON LOT TO: in. SePtic tank/lift station on lot Absorption field on lot Public sewer main On adjacent lots On adjacent lots Public sewer manhole/cleanout Sewer/septic service line Holding tank Animal containment areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 1 0 ~ + Property line 1 0 ~ + Water mai~' 10 ~ + Water service line 1 0 ~ + 'Wells on adjacent lots 200 ~ + SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10 ~ + 'Water Service line 1 0 ~ + Curtain drain None ][no~z~ F. COMMENTS Building foundation 1 0 ~ + Surface water 1 O0 ~ + Wells on adjacent lots 200 ~ + G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Paul E. Pinard, P.E. Date 5/9/1.1 Absorption field 10 ' + Surface water 1 O0 ' + Water main 10 ~ + Driveway, parking/vehicle storage 1 0 ~ + COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number PINARD ENGINEERING P.O. Box 871347 Wasilla, AK 99687 (907) 357-ENGR (3647) ADEQUACY TEST LOCATION: Lot 13, Block 5, Knik View Estates APPLICANT: Gerald & Joy Meaney PO Box 876067 Wasilla, Alaska 99687 SEPTIC TANK TYPE/SIZE: Steel/1250 Gallons, per MOA Records ABSORPTION SYSTEM: 5 Wide Trench (4'ED), per MOA Records DAILY FLOW: 4 BEDROOMS x 150 GAL/BR = 600 Gallons JOB NUMBER: 11-108 DATE OF TEST: 5/2/11 FIELD STAFF: PJ Pinard NUMBER OF BEDROOMS: 4 SCUM: 0.0' SLUDGE: Minimal NEEDSTO BE PUMPED: Yes No XX CURRENTLY IN USE: Yes XX No TEST DATA Time Flow Volume Cumulative Septic Tank Septic Soil Absorption System Comments Rate Volume Tank ~ (GPM) (GALs) (GALs) Liquid Level A Level Monitor A SAS Monitor ~ SAS * Tube 1' Level Tube 2* Level 8:15 4.7 4.0' 2.8' Start Flow - Meter 44600 8:30 4.7 70 70 4.1' 0.1' 2.9' 0.1' 44670 8:45 4.7 70 140 4.1' 0.0' 2.9' 0.0' 44740 9:00 4.7 70 210 4.1' 0.0' 3.0' 0.1' 44810 9:15 4.7 70 280 4.1' 0.0' 3.0' 0.0' 44880 9:30 4.7 70 350 4.1' 0.0' 3.1' 0.1' 44950 9:45 4.7 70 420 4.1' 0.0' 3.1' 0.0' 45020 10:00 4.7 70 490 4.1' 0.0' 3.2' 0.1' 45090 10:30 140 630 4.1' 0.0' 3.2' 0.0' Stop Test - 45230 RECOVERY Date Time ST MT SAS MT 5/2 11:00 4.0'/-0.1' 3.0'/-0.2' AM 5/2 11:35 2.8'/-0.2' AM *ALL MEASUREMENTS IN FT. TEST: PASSED XXX FAILED COMMENTS: System appears to be operating satisfactorily. There was 2.8' of measurable liquid in the SAS MT prior to beginning the test. With the addition of 630 gallons to the system (more than the design daily flow), the level rose to 3.2', leaving about 0.8' of the ED still available. Recovery measurements showed a return to the starting condition 65 minutes after stopping the test flow. Reviewed by: Paul Pinard '~Z--~ Date: 5/6111 flexmls Web · Page 1 of 1 r - ? AS-BUILT I hereby certify that I have surveved the following :'VroPerty: L~ 7" I ~, ' " An~:hor~ge R .ec'o. rding Precinct, Alast~a, and that the~ ments'~ituated therebn are ~ithm the property lines a overlap or encroach'on the Property lying adjacent the r~d h~npro~,emeh~s 'bn pto?erty lying adjacent thereto on the premises in-question and t~at there are no r transmission lines or other visible easements on said except,as indicated hereod' http://members.x-mls.com/cgi-bin/mainmenu.cgi?cmd=url+report... 5/2/2011 ~ Pumping PO Box 773415 Eagle River. AK 99577 (907) 694-6454 r IBillin.q Information Bruce Scanes Po Box 671813 Chugiak, AK 99567-1813 (907) 688-6265 i Job Site Information Bruce 22500 Judd Street Chugiak, AK 99567 (907) 688-6256 Additional Location Comments Diagram: Job Description: P.O. Number: Terms: Salesrep: Map Book: Cross Streets: 1250g Service Agreement Number: 032035 Order Date: 15-Sep-2010 Service Date: 24-Sep-2010 12:0 Technician: Mike & Dan Net 30 Tax %: 0 Karlia Job Type: Repeat Map Grid: 13 Knik Vista Street 'Last Serv '10/1512008' 1250g O'D O/c Job Comments: S:~Diaqrams\16305.bmp Gallons Planned: 1250 #'s on are green home w/dark green trim, rv in dw Pipes @ back under deck, will have board removed to access Service Type Septic Serv 1250K Qty Price Each Tax? 1 $185.00 No Gal. Actual: Hose Length: 2 Double Tank: [] Pump System: [] ,.____ Baffles Inlet: [] Baffles Outlet: [] .... NonTaxable Total Taxable Total Tax Total Grand Total Estimated Charges: $185.00 $0.00 $0.00 $185.00 Actual Charges: Customer agrees to the terms and conditions shown. THIS IS A BINDING AGREEMENT. Signature and Titl~f Customer Repl..e,~e'~'~tive Date Accepted by ~Rs Pumping Date Accepted For your added convenience we accept; Amedcan Express, Dicover, Visa and Master Card payments over the phone. After 30 Days account will be turned over to COLLECTIONS. $30.00 For NSF Checks Returned. Municipality of Anchorage Development Services Departme Building Safely Division On-Site Water and Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www,muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING ParcelI,D. O51-O43-53 1, GENERAL INFORMATION Complete legal description Location (site address)' COSA# b 0LII3 Expiration Date: Lot 13r Block 5~ Knik View Estates 22500 Judd Drive Chu~iak~ Alaska 99567 Current Property owner(s) Mailing address Brett & Tamara Neukam Dayphone(90?) 688-4593 22500 Judd Drive Chu~iak, Alaska 99567 . Lending agency Day phone Mailing address Real Estate Agent Mailing Address Les Bailey g Associates Dayphone(90?) 689-6451 Prudential/JW 16635 Centerfield Drive Ea~le River, Unless otherwise requested, COSA will he held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 3. TYPE OF WATER SUPPLY: Individual Well [] Individual Water Storage [] Community Class A Well [] Public Water System [] TYPE OF WASTEWATER DISPOSAL: Individual On-site [] Individual Holding Tank [] Community On-site [] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On-Site Systems Approval are required for the transfer of title (except between spouses) for propedies served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On-Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results. (Certificates may be reissued for a period of up to one year with valid water samples,) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. A~ 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage flies and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of inst~,ation. Name of Firm Pinard Engineering Address PO Box 871347 Wasilla~ Alaska Engineer's Printed Name Paul E. Pinard, P.E. 5. DSD SIGNATURE Approved for /--/ bedrooms. Disapproved. Conditional approval for .__ Phone(907) 357-364? 99687 Date -."1~. ~/~' '~0~/;' '.- · .,,~-.. ..~ ~, bedrooms, with the following stipulations: Attachments: COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory X Arsenic Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: /~/L//~) ~' Municipalily of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 Elmore Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST LegatDescription: Lot 13~ Block 5¢ l~ntk Vie~ Estates ParcellD:051-O/,3-53 A. WELL DATA Well type /[ Date completed Total depth If A, B, or C provide PWSID # .2_1..B./,09 Well Log (Y/N) Sanitary seal (Y/N) Wires properly protected (Y/N) Cased to ~ft. Casing height (above ground) FROM WELL LOG AT INSPECTION in. Date of test Static water level ft. ft. Well production gp.m. g.p.m. WATER SAMPLE RESULTS: ,Coliform Arsenic: coloniesll00 mL Nitrate mg/L ug/L date of sample: Other bacteria Collected by: colonies/100 mL B. SEPTIC/HOLDING TANK DATA .Tank Type/Material 8ept,:te/,C;t, eel Tanksize 1250 gal. Number of Compartments 2 Foundationcleanout(Y/N).¥ea Depression over tank (Y/N) No Date of pumping 10/15/O8 Pumper ,TP,.s ~Pump::in~ Date installed 8/130 - 9//-,/02 Cleanouts (Y/N) Yes High water alarm (Y/N) NA C. ABSORPTION FIELD DATA Date installed 9/02 Length 51 Total depth 8 ft. Soil rating (g.p.d.lft: [-~..~'~ffn~ I. 2 ' System type 5 Wide Trench ft. Width 5 ft. Gravel below pipe Eft. absorption area 51 0 ft: Monitoring tubeYe ~ Depression over field No Date of adequacy test 1 1/28/08 Results (Pass/Fail) Pass Fluid depth in absorption field before test 16 in. Wateradded6~Ogal. Elapsed Time: 1.3 5 min. Final fluid depth 1 6 in~.'t'ter- I Absorption rate Any rejuvenation treatment (past 12 mo.) (Yin & type)None Knoun For 4 bedrooms Newdepth 25 in. >= 600+ g.p.d. If yes, give date D. LIFT STATION NA Date installed 'Pump on" level at Datum Size in gallons in. 'Pump off' level at Cycles tested Manhole/Access (Y/N) in. High water alarm level at in. Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELLON LOTTO:NA - PUBLIC WATER SXSTEM _ NO WELL ON LOT Septic tank/lift station on lot Absorption field on lot Public sewer main On adjacent lots On adjacent lots Public sewer manhole/cleanout Sewer/septic service line Animal containment areas Holding tank Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 10 t ~. Property line. 107 + Absorption field 10't + Water main 107+ Water service line 107+ Surface water 1OO~+ Wells on adjacent lots .200 ~ -I- SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10 ~ + Water Service line 10 ~ -I- Curtain drain ti'one Enown Building foundation .10 t + Surface water. 100 ~ + Wells on adjacent lots 200 ~ + Water main 10 ~ + Driveway, parking/vehicle storage F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Paul E. Ptnardt P.E. Date 12/.3/08 COSA Fee $ Date of Payment Receipt Number (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number PINARD ENGINEERING Paul E. Pinard Registered Engineer/AK & ID P.O. Box 871347, Wasilla, AK 99687 (907) 357-ENGR(3647) ON-SITE DRINKING WATER AND SEWER SYSTEM ENGINEER'S EVALUATION PROPERTYDESCRIPT1ON: LOT t3, BLOCK 5, KNIK VIEW ESTATES This property is developed to serve a single-family residence with a total of 4 bedrooms. Owner's Name(s): Bmtt & Tamara Neukam Ovmer's Address: 22500 Judd Drive Chugfak, Alaska 99567 BuyeFs Name(s): Bruce & Theresa Scanee BuyeCs Add.ss: ~?xN-SITE DRINKING WATER SYSTEM: X This property is served by a Public Water System approved by ADEC. A recent drinking water sample was tested at an ADEC certified laboratory and was found to meet c~rrent ADEC drinking water standards for total celiform bacteria. NOTES: ON-SITE WASTEWATER DISPOSAL SYSTEM: A new wastewatar disposal system has been Instatled. Based on periodic visual observations, it appears this system was constructed in general conformance w~th current 18 A,&C 72 regulations and ADEC policies. This wastewater disposal system was installed by an ADEC Certified Installer and approved by ADEC. ;KX The existing wastewater disposal system was tested in accordance with cu~ent MOA and ADEC policy and found to bo ^_ _operating satisfactorily. The readily identifiable features of this system were observed and documented. ~ Xx It appeam that this system meets requirements of the ADEC and the MOA, based on record infom,,ation at the ' - ' MOA. This system does not meet the horizontal separation distance requirements of 18 AAC 72 regulations and conformance with the vertical separation requirements of these regulations, to seasonal high groundwater and Impen~eable layers, is unknown. Components are unknow~ end it is undocumented with ADEC. NOTES: This report does not constitute e guarantee of any tdnd, explicit or implied, as to the futura peffomtance of this water supply or wastewater disposal system. It does accurately pork'ay the conditions found on the date they were tested and/or documented. PINARD ENGINEERING P.O. Box 871347 Wasilla. AK 99687 (907) 357-ENGR (3647) ADEQUACY TEST LOCATION: Lot 13, Block $, K~lk Vlew Estate~ APPLICANT; Brett & Tamara Neukam 22500 dudd Drive Chuglak, AJeska 99567 SEPTIC TANK TYPE/SIZE: Steblf125~ Galto~s, per MOA Records A~SORPTION SYSTEM: 5 Wide Trench (4' ED), per MOA Records DAILY FLOW: 4 BEDROOMS x 150 GAL/~R · ~X) Gallo~m JOB NUMBER: 08-272 DATE OF TEST: 11/28~08 FIEI.D STAFF; PJ Pina~d NUMBER OF BEDROOMS: 4 SCUM: 0.0' SLUDGE: Minimal NEEDSTOBEPUMPED: Yes No XX CURRENTLY iN USE: Yes XX No TEST DATA Time Flow Volume Cumulative Septic Tank Septic Soll Absorption System Comments Rate Volume Tank pJ~ (GPM) (GALs) (GALs) Liquid Level ~, Level Monitor ~, ,SAS Monitor ,~ SAS Tube 1° level Tube 3' Level 6:45 4.7 4.0' 1.3' Start Flow- Meter 370300 7:00 4.7 70 70 4.1' 0.1' 1.4' 0.1' 370370 7:15 4.7 70 140 4.1' 0.0' 1.6' 0.2' 370440 7:30 4.7 70 710 4.1' 0.0' 1.7' 0.1' 370510 7:45 4.7 70 280 4.1' 0.0' 1.9' 0.2' 370580 8:00 4.7 70 350 4.1' 0.0' 2.0' 0.1' 370650 8:15 4.7 70 420 4.1' 0.0' 2.0' 0.0' 370720 8;30 4.7 70 490 4.1' 0.0' 2.0' 0.0' 370790 9:00 140 630 4.1' 0.0' 2.1' 0.1' Stop Test- 370930 RECOVERY Date T~me ST MT SAS MTt 11/28 9:10 4.0/-0.1' 2.0'1-0.1 ' PM 11/28 9:30 1.8¥-0.2' PM 11/29 1:00 1.3'1-05' PM · ALL MEASUREMENTS IN FT. TEST: PASSED XXX FAILED COMMENTS: System appears to be functioning in n normal manner. There was 1..3' of mensurable liquid in the SAS MT pr~o~ to b~glnnlng the test. ~Rth the addition of ~10 gallorm to the ayetem (mom ttmn the Oeslgn daily flow), the level rose to 2.0', leaving half of t~e ED of the SAS still available. Recovery meesummen~ ehowed ~ showed ~atlsfactory abeorptiom ~ Reviewed by: Paul PInard ~ Date: '12/2/08 i J ! · ..! ~¢- ....¢.' / ' 'VL . .~'.,,~,.-- .- I . /'~'~; ,, ~-~' ! ~*, ...~_~,-~.. / ! ~.-.~ _.::/ ,'.~ · ' ' ,,~ e~ ~a~f~ ~u~ stmdure(sJas / .: / ~%z-¢ "'"' 4/ · ?'"' ~o'""-- o'" -- i'... / '' e~ , - / ; ! I i :,/ , I . / .~; ! :'' '7'*'' ' "':'' -"'""~ i/ ~ ~" ~' ~' D -~ ~ ~~,T I hereby ce~t~y that l have survey, ed the fottowing described ~.~.*~.~X)'X~¥,, w ~ . ~ ~ ,-~ 'T'. Anchor'age Recorc[~8'l~-ech~et, Alaska, and tlut the ird~rove. I .,e..~ .~ -, /~'~ ~ ~:, menls'Mtuated thereon are w~thin Ihe.propert7 lines and do not i _'r',L~' ..° ~ % ..-- ,~ overlap or encroach'on the ptopeTty lying adjacent thereto, that I "'~'~ "'er ~. · ,,~>-~'..: %7 -,t . no improvements'on ptoT~tty 1Ting adjacem thereto enc~oac~ I .. 4gib *'-~, ~, ~:., on th~ premise~ tn quesUon and that ~here are no ~oadways, · '~' % "~ "~"~ ~.s*~ ~'anSm.tSsion I~es or other visible easements on said [ 'Sa ~.~,~ Robert C. ~:.h~on .,r.~ ~ ~Z Date~ at'Eagle Raver, AlaSka I e.~,.'.. . ~a-:z ,,,,4'~.¢,~ this I~ r~ da¥of ~:r_~. 200"~ . ~,x- ',~ ~'~- -'~ oox 77-04~, t.a$1e R~er, Alaska 99577 ~t~one (9O7) 694-2.,~43 Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING ParcelI.D. 051.043~53 1. GENERAL INFORMATION Expiration Date:. Complete legal description Lot 13. Block 5, Knik View Estates Subdivision Location (site address or directions) Judd Drive Current Property owner(s) MM&M Contracting Mailing address P,O. Box 670495 Lending agency Mailing address Real Estate Agent Mailing Address Unless otherwise requested, HAA will be held by DSD for pickup. NUMBER OF BEDROOMS: Four 14) Chuqiak~ AK 99567 Day phone 688-1236 Day phone Day phone 3. TYPE OF WATER SUPPLY: Individual Well Individual Water Storage Community Class A Well Public Water System TYPE OF WASTEWATER DISPOSAL: r'"l Individual On-site [] r"] Individual Holding tank [] [] Community On-site [] [-] Public Sewer [] The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority' Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues HAAs upon request to homeowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample results less than 30 days old. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on- site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Enqineerin.q Address P.O. Box 240773 Anchoraae. AK 99524 Engineer's Printed Name Michael E. Anderson, P.E. DSD SIGNATURE Approved for 47' Disapproved. Conditional approval for bedrooms. Phone 522.7773 Date 2/412003 ..... · [7] '''''~'~-~*~ ' ti 'L ~'~-E'/~~'''wk'['~' ..... I...~. ~ ~[ MICHAEL E. ANDERS~ ~ ~. bedrooms, with the following stipulations: Additional Comments 'Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Maintenance Agreements Supplemental Engineer's Report Other Original Certificate Date: ~ /1: /~ 7 Municipality of Anchorage Development Services Department Building Safety OMslon On-Site Water & Wastewater Program 4700 South Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage,ak.us (907) 343-7904 HEALTH AUTHORITY APPROVAL CHECKLIST Legal Description: ,.L~t 13. BlOck $. Knlk ~lew Estates A. WELL DATA Well type ~ Date completed Total depth , ft. If A, B, or C provide PWSID # Sanitary seal (Y/N) Cased to fL Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform ~,colonlesll00 mi. Date of sample: ........ SEPTIC/HOLDING TANK DATA Tank Type/Material ..,~eptlc/$teel., Tank size ..1~50 gal. Foundation cleanout (Y/N) ~ FROM WELL LOG Date of pumping C. ABSORPTION FIELD DATA Date installed gl4/2002 Length ~! Total depth ?,$ fL Data of adequacy test Nitrate ' mgJI. Collected by: Number of Compartments Depression over tank (Y/N) · , , Pumper NewConstmctlon Soil rating (g,p.dJft= or ~/bdrm) t.2 GPD/SF ft. Width ~ ........ ft. Eft. absorption area 610 ~ Monitoring tube ResUlts (Pass/Fail) Fluid depth In absorption field before test ...... In. Water added, Elapsed Time: , min. Final fluid depth in. Any rejuvenation treatment (past 12 mo,) (Y/N & type) I~ Parcel ID: 0514)43.53 well Log (Y/N) Wires properly protected (Y/N) Casing height (above ground) AT INSPECTION ft. g,p.m. Other bacteria coloniesllO0 mi. Date installed 8/30/2002 Cleanouts (Y/N) y High water alarm (Y/N) If yes, give date System type 5' Wide Shallow Trench Gravel below pipe ~ fl. Depression over field N For bedrooms , gal, New depth in. Absorption rote >= g.p.d. D. LIFT STATION Date installed 'Pump on' level at in. Datum E. SEPARATION DISTANCES Size in gallons 'Pump o~ level at Cycles tested in. SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot NIA Absorption field on lot NIA ' Public sewer main FIIA Sewer/septic service line Manhole/Access (Y/N) High water alarm level at Meets alarm & circuit requirements? On adjacent lots NIA On adjacent lots NIA Public sewer manholelcleanout NIA Holding tank NIA SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main J41A Water service line >10' Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property/line >10' Building foundation >10' Water Service line >10' Curtain drain None I~loted F. COMMENTS Lot is serv~ by AWWU water eystern. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Pdnted Name Michael E. Anderson, p.E. Date 2/4/2003 Waiver Fee $ Date of Payment Receipt Number Surface water >100' Wells on adjacent lots >200' HAA Fee $~ .~7~' ~ Date of Payment Receipt Number ~'~fO ~'~, ,.~ ~.' (Rev. 12/00) Absorption field >5' Surface water >t00' Water main >10' Driveway, paddng/vehicie storage >25' in,