HomeMy WebLinkAboutEAGLE RIVER VALLEY RANCHETTES LT 10B
MUNICIPALITY OF ANCtIORAGE
Hea}"~ and Environmental Proteq~n
Fourth Floor West
825 L Street
Anchorage, Alaska 99501
279-2511, x 224, 225
INSPECTION REPORT ON-SITE SEWAGE DISPOSAL SYSTEM
LOCAT,ON_ .. ,:OA,
SEPTIC TANK: ..~]~ ~J
NUMBER OF ~
FROM WELL ~ E.ANUFACTURER MATE RIAL ...... r-~~ COMPARTME,,TS
INSIDE LENGTH ~ INSIDE WlDTII ~ ~ LIQUID DEPTH ~ LIQUID CAPACITY ~LLONS.
TILE DRAIN FIELD: ~
,_O
DISTANCE FROM WELL C_J:~m,,4~. ¥~FOUNDATIOhl 'Z-~;~'"
~ of Lines J OISTANC[ BETWEEN LINES
~' TOTAL LENGTH
NEAR[SI LO' UN£ .... ~.._.~______OF LINE
~JtJ /~_ TRENClt WIDTH_~._.~ IN. TOTAL EFFECT IVE
ADSORPTION AREA ~-'~.-~--~.~"~ SQ. fT. LENGTH OF EAcH LINE ~ ~
____MATERIAL [~[NEATtt TILE . . IN. ABOVE TILE
SEEPAGE PIT:
DIAMETER __ OR WIDTH LENGTH 0 DEPTH
Log Crib Rings Crib Size: DIAMETER_ DEPTH DISTANCE FROM: WELL
TOTAL EFFECTIVE
BUILDING FOUNDATION NEAREST LOT LINE .__ ABSORPTION AREA {WALL AREA)
SQ. FT.
Well ~
Class: ~0 Dept'h:
Well Di~ To: Lot Li~e
Bldg: Sewer Line:
Pipe M~terials:
# of Bedr?oms:
Installer.
Remarks: ~;1~
I .i I i_l.,J LL_L
DATE
P~RMI T HO.
E:,EPFtRTMENT~"T HEFtL. TH RND EN',,.'ZRONblENTRL~ROTECTION LD.,-~
825 ' ~." STREET, RNCHORRGE., RK. 9_ .,0± '
279. -251i ~l~_~/s. ~-,Q ~-'7 '7
Cmr~--S I TE SEI..IEF-: F'EF-."I','I /. l
> /:JO
RF'F'L I C:RNT
LOCRT I ON
LEARL
,F..',/FF'F,,TT ..HLk INS E:nX 6:=:'~:
[,IH I RLRP~R'¢
L1CIE: ERGLE RIVEF.: RRNCHETTES
LOT SIZE
i7955 SC!URRE FEET
Tb'F'E OF SOIL RBSORBTIOII S~'STEf.1 IS: TRENCH
1,1RXIMUM NUME:ER OF E:EDROOMS = ~
SOIL F.:F~TING (SIS.! FTFE:F.:)= 15C.~
THE REQUIF.:EC, SIZE C,F THE SI3IL BE:SOF.:F'TION -,¢_,TEM IS:
[:,EF'TH= :1. ~Z-~ LEI'-.I mS T H = -1-6 I_S F-' I=I '-.-' E I [~EF"TH= 5
THE LENGTH DIMENSION IS THE LENGTH (IN FEET) OF THE TRENCH OR DRRIHFIELD.
THE DEPTH OF B TRENCH OR PIT IS THE DISTRNC:E E:ETI4EEN THE SURFRCE OF THE
GF..:OUN[:, RN[:, THE B',OTTOM OF THE E>,',CRVRTION (IN FEET).
THERE IS NO SET 14IDTH FOR TRENCHES.
THE GRR';,'EL DEPTH IS THE MINIMUM DEPTH OF GRRVEL E:ETP4EEN THE OUTFFtLL PIPE
RND THE E:OTTOM OF THE E,s(CR',,,'F~TION (IN FEET).
TI-..II:I ( 2 > I I'-ISF'EI::T I I:ll'-,l__c- I:-I F-." E F-:E,_:!I_I I ICED
E:~CKFILLING OF RN'¢ S'¢STEM I,IITHOUT FINAL INSPECTION RND RPPRO',/~L E','T' THIS
DEPRRTMENT [,IILL E',E SUE:JECT TO PROSECUTION.
MINIMUM [:'ISTRNCE E',ETP]EEN R PIELL RND RN'T' ON-SITE SEI,IRGE DISPOSRL S*r'STEbl IS
±(~E~ FEET FOR ~ PRIVRTE I,IEI_L OR 20E~ FEET FOR ~ PUE',LIC I,]ELL.
SPECIFICF~TIONS RND CONSTRUCTION DIRGR~MS 8RE RVRILRE:LE TO INSURE PROPER
I HSTRLLRT I ON.
PEF-:I--11 T '-.-'RL I C:, FOF-: OI'-.IE "T'EI=IF.: FF:m-If.1 I S"--~-I_l P_-
I CERTIFY THBT
l: I BM FRMILIRR I4ITH THE REQUIREMENTS FOR ON-SITE SEWERS RN[.', WELLS RS SET
FORTH E','~' THE f'IUNICIPBLITY OF RNCHORRGE.
2: I 14ILL INSTRLL THE SVSTEM IN RCCORDRNCE I,IITH THE CODES.
'~:: I UNDERSTRND THRT THE ON-SITE SEPIER S?STEM i'lR~r' REQUIRE ENLRRGEMENT IF THE
RESIDENCE IS REMODELED TO IHCLUDE MORE THBN -% BEDROOMS.
RPPLICRNT EVERETT CRLKINS
I ..... YE[ EI'T __-[:'8T
May 31, 1977
R & M No. 751170
Mr. Everett Calkins
Citation Road
Eagle River, Alaska 99577
Subject: Soils Investigation for Sanitary Sewer System, Lot 10-B
Eagle River Valley Ra~chettes Subdivision, Eagle River, Alaska
Dear Mr. Calkins:
At your request of May 27, 1977, we conducted a subsurface soils investi-
gation at the proposed location of the sanitary sewer system on the
subject lot. The investigation complied with those procedures required
by the Municipality of Anchorage, Department of Health and Environmental
Protection.
This investigation, which was accomplished on May 27, 1977, consisted of
a test hole excavated to a depth of 15 feet below the existing ground
surface. The location of the test hole is shown in attached Drawing A-
01. Excavation took place with a backhoe. In addition, all material
excavated was continuously monitored by an experienced engineering
geologist.
The topography at the excavation site is generally gently-sloping to the
west. At the time of the investigation, the site had original vegetation
and ground cover. The top of the'test hole was located at original
ground surface. The soils encountered in the excavation are shown in
the test hole log in Drawing A-01. Groundwater was not encountered in
the test hole. Bedrock was not encountered. Subsurface conditions may
vary in other parts of the lot.
Based on the visual classification of the soil and the requirements set
forth by the Municipality of Anchorage, we determined that a percolation
test was not necessary within the test hole on the subject site.
We appreciate this opportunity to be of service to you. Please contact
us if you have any questions concerning this letter.
Mr. Everett Calkins
May 31, 1977
Page 2
Very truly yours,
R & M CONSULTANTS, INC.
Jeffrey M. Ayres
Staff Geologist
JMA/JS~/mu
Attachments: Drawings A-01, B-01, B-02
XC: Dept. of Health & Environmental Protection
Jim McCaslin Brown, Ph.D.
Head, Earth Science
Department
IX)C~TIO~ SKETCH
J
WHIRLAWAY ROAD
35~
TH-1
Lot 10B,
Eagle River Valley
Ranchettes
Not To Scale.
Distances shown are approximate
and have not-been measured by
surveying methods.
TEST HOLE LOG
Scale: 1"=3'
0o01
ORGANIC SANDY SILT
Medium Dense
1.0t
GRAVELLY SA~ID W/TRACE SILT
'(SP)
Brown, Slightly Moist,
Very Dense
Groundwater was not encountered.
This log depicts subsurface soils
observed within the test hole at the
location shown.
See Drawings B-01 and B-02 for
explanation of symbols.
KD: JMA
DATE: 5-31-77
SCALE:see above
LOCATION SKETCtI AND
TEST }IOLE LOG
EV~. RETTE CALKINS
JLDW6. NO. A-O1
01G66 996 ~
H~DI"IO~O~ V~IV ~E)~
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH & HUMAN SERVICES
Division of Environmental Services
On-Site Services Section
P,O. Box 196650 Anchorage, Alaska 99519-6650
343-4744
Parcel I.D. # t'~(") - .r~
1. GENERAL INFORMATION
Complete legal description Lot 10~
CERTIFICATE OF HEALTH AUTHORITY
APPROVAL FOR A SINGLE FAMILY DWELLING
HAA #
Eagle R/vet Falley R~nchc~t~6
~-34-
Location (site address or directions)
Prope~y owner
Mailing address
10538 Cr~t Vim Lane
10538 Cr~6t Flew Lane
Eaqle Rluer, AK
Day phone 694-8941
'Eagle River, AK 99577
Lending agency
Mailing address
Agent
Address
Day phone
Day phone
e
e
Unless otherwise requested, HAA will be held for pickup.
NUMBER OF BEDROOMS:
TYPE OF WATER SUPPLY:
Individual .well
Community well
Public water
NOTE:
If community well system, provide written confirmation from State ADEC attest-
ing to the legality and status of system..
TYPE OF WASTEWATER DISPOSAL:
Individual on-site
Holding tank
Community on-site
Public sewer
NOTE:
72-(325 (Re~, 1/91) F~o~t MOA 1121
If community wastewater system, provide written confi~'mation from State ADEC
attesting to the legality and status of system.
e
STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my
investigation of this Health Authority Approval application shows that the on-site water supply
and/or wastewater disposal system is safe, functional and adequate for the number of bedrooms
and type of structure indicated herein. I further (,erify that based on the information obtained from
the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is in compliance with all Municipal and State codes,
ordinances, and regulations in effect on the date of this inspection.
Name of Firm · ~ Phone ~ Z..~-'~ ~
S&S ENGINEERING /~, /
Address .... _~_:-::~'..,-~_.-~,,~d~.~__~_ '/ //
/ ,,,, .."J/ /.,,,'.
,
;'~ .% ....~,.,
DHHS SIGNATURE
X' Approved for '~'x/w-~'~- (~) b~d rooms.
Disapproved.
Conditional approval for bedrooms, with the following stipulations:
Additional Comments
The Municipality of Anchorage Department of Health and Human Sen/ices (DHHS) issues Health Authority
Approval Certificates based only upon the representations given in paragraph 5 above by an independent
professional engineer registered in the State of Alaska. The DHHS does this as a courtesy to purchasers of homes
and their lending institutions in order to satisfy certain federal and state requirements. Employees of DHHS do not
conduct inspections or analyze data before a certificate is issued. The Municipality of Anchorage is not
responsible for errors or omissions in the professional engineer's work.
72-02~(Rev. 1/91) Biicl( MOAI21
Municipality of Anchorage
Department of Health and Human Services
HEALTH AUTHORITY APPROVAL CHECKLIST
Legal Description: ~'~' \~:::~ ~' ~,~t,~- ~--,.t~,.z.- Parcel I.D. O ~ -- ~ ~ ~ ·
A. Well Data
Well type
Log present (Y/N)
Total depth
Sanitary seal (Y/N)
Date of test
Static water level
If A, B, or C, attach ADEC letter. ADEC water system number.
Date completed Driller
.Cased to .Casing height,._
' .Wires properly~
FROM WELL LOG ~T INSPECTION
g.p.m.
SEPARATION DISTANCES FROM WELL TO:
Septic/holding tank on lot 'z-~,~ ~'
Absorption field on lot ~--~c, ~'
Public sewer main
Sewer service line
D~~ample:
; On adjacent lots
; On adjacent lots
.Other bacteria
.Collected by:
B. SEPTIC/HOLDING TANK DATA
Date installed
'Cleanouts ~/N)
High water alarm (Y~
Tank size \ ~C;, ~,
Foundation cleanout~ ~.
Compa~ments
sDate of pumping
EPARATION DISTANCES FROM SEPTIC/HOLDING TANK TO:
.On adjacent lots '?\ ~
Absorption field t ¢>
Well(s) on lot
To property line '55'
Surface water/drainage
Depression (~Y~
Alarm tested (Y/N)
:,.
Foundation
.Water main/service line
72-026 (3/93)* Fro~t CONTINUED ON BACK PAGE
C. LIFT STATION
Date installed
Size in gallons
Vent (Y/N) 'Pump on" level at
High water alarm level ~cles tested
Meets MOA electrical codes (Y/N)~.~..-'"'"'"'~
SEPARATION NCE FROM LIFT STATION TO:
~ On adjacent lots
Manufacturer
Manhole/Access (Y/N) ~
Surface water
D. ABSORPTION FIELD DATA
Date installed
Length '~ ~' ~
Total absorption area ~r't,-o ~
Date of adequacy test Jo,-- I ~,--'5'--~
Water level in absorption field before test
Peroxide treatment (past 12 months) (Y~
\~"1 q Soil rating (GPD/FF)
Width '~,c:, "' Gravel thickness ~"
Cleanout present (~1)
Results ~l~!~il)
.System type
Total depth
Depression over field (Y,~
for ~ Bedrooms
After test CZ)
If yes, give date
SEPARATION DISTANCE FROM ABSORPTION FIELD TO:
Well on lot .'z.~c, ~On adjacent lots
To building foundation '?--"~ ~ ~
On adjacent lots'~-~ ~ ~
Surface water 1 '~:>
Cu.ain d ain
Property line
.To e~sting or abandoned system on lot
.Cutbank ~ ~,z,- .Water main/sen/ice line
Driveway, parking/vehicle storage area
E. ENGINEER'S CERTIFICATION
I certify that I have checked, verified, or conformed t~fl~OA and HAA guidelines in effect o.~.t~,da~e~.~is insPection.
/ / ..;~: O~',,z'~.._ ,7"~
Engineer's Name 17034 Eagle R,ver Looj~'RoadNe 204 -
Eagle River, Alask~,~r9577 . /
HAA Fee S
Date of Pa ent
Receipt Number
~6 (~3)' ~ck
Waiver Fee $
Date of Payment
Receipt Number
MUNICIPALITY OF ANCHORAGE
DEPARTMENT OF HEALTH AND ENVIRONMENTAL PROTECTION
DIVISION OF ENVIRONMENTAL HEALTH
CERTIFICATE OF INSPECTION FOR HEALTH AUTHORITY APPROVAL
OF ON-SITE SEWER AND WATER FACILITY
264-4720
Application Date
GENERAL INFORMATION
(a) Legal Description (include lot. block, subdivision, section, township, range)
Location (address or directions)
(b) Applicant NameP._~-a~//.//~'~.-/'3wv'P'~*~' Telephone: Hem~ ~;:¢z./.,3",~c::~ Business
Applicant Address ~"'~'~f'
(c) Applicant is (check one): Lending Institution I-I; Owner/builder []; Buyer I-I; OtherJ~ (explain);
(d) Lending Institution ~ c:~ /~J _~ Telephone
Address
(e) Real Estate Company and Agent
Address
Te!ephone
(f) ,l~the '~)AA to the followir~g ~ddress:
TYPE OF RESIDENCE
Single-Family'- Multi-Family []
Number of Bedrooms -~
Other
WATER sUPPLY
Individual Well [] Community [] Public~.
Note: If community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
4. SEWAGE DISPOSAL
Onsitex[~ Public [] Community [] Holding Tank []
%
Note: It community well system, must have written confirmation from the State Department of Environmental Conservation
attesting to the legality and status.
Page I of 2 72-0~5 (tl,84}
ENGINEERING FIRM PROVIDING INSPECTIONS, TESTS, FILE SEARCH, DATA AND INFORMATION
As c~rtified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation of this Health~
Authority Approval shows that the on-site water supply and/or wastewater disposal system is safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained
from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or
wastewater disposal system is in compliance with all Municipal and State codes, ordinances, and regulations in etfect on
the date of this inspection.
Name of Firm
Telephone ..
Address 'c, ,,3LE
Date
DHEP APPROVAL
Approved for bedrooms by
Approved ~ Disapproved
Terms of Conditional Approval
Date
Conditional
CAUTION
The Muncipality of Anchorage Department of Health and Environmental Protection (DHEP) issues Health Authority
Approval certificates based solely upon the representations given in paragraph 5 above by an independent professional
engineer registered in the State of Alaska. The DHEP does this as a courtesy to purchasers of homes and their lending
institutions in order to satisfy certain federal and state requirements. Employees of DHEP do not conduct inspections or
analyze data before a certificate is issued. The Municipality of Anchorage is not responsible for errors or omissions in the
professional engineer's work.
Page 2 of 2
72-025 (11/84)
WELL DATA
Well Classification
Well Log Present (Y/N)
Total Depth Cased to
Static Water Level
Casing Height Above Ground
Electrical Wiring in Conduit (Y/N)
Separation Distances from Well:
To Septic/Holding Tank on Lot
To Nearest Edge of Absorption Field on Lot ,,~'4~) ~ ~''
To Nearest Public Sewer Line CleanoutJManhole
Water Sample Collected by
Water Sample Test Results
Comments
MUNICIPALITY OF ANCHORAGE (MOA)
HEALTH AUTHORITY APPROVAL (HAA)
CHECKLIST - FEBRUARY 1984
264-4720
Legal
C. D.E.C. Approved~'~)"
Date Completed Yield
Depth of Grouting
~/'/Pump Set At
~o~nitary Seal on Casing (Y/N)
Depression Around Wellhead (Y/N)
; On Adjoining Lots
; On Adjoining Lots
To Nearest Public Sewer
To Nearest/Sewer Service Line on Lot
~V~b~/ ;Date
SEPTIC/HOLDING TANK DATA
Date Installed ~1,~~1
Standpipes ~N')' Air-tight Caps
Depression over Tank
Pumping/Maintenance Contract on File (Y/N)
Holding Tank High-Water Alarm (Y/N)
Separation Distances from Septic/Holding Tank:
To Water-Supply Well '~,~) ~:~ ·
To Property Line ,~' /
To Water Main/service Line .~. 0 ·
Course
Size..[C:X~ (:::) No. of Compartments
Foundation Cleanout {~')
Date Last Pumped
;for
Teml~orary Holding Tank Permit (Y/N)
To Building Foundation /fO ·
' To Disposal Field JO ~ '
To Stream, Pond, Lake, or Major Drainage
Comments
Page 1 of 2
72-026(11/84)
C. ABSORPTION FIELD DATA
Soils Rating in Absorption Strata
Date Installed
Width of Field
Square Feet of Absorption Area
Depression over Field
Results of Last Adequacy Test
Separation Distance from Absorption Field:
Type of System Design
Length of Field
Depth of Field
Gravel Bed Thickness
'~,O ~"* Standpipes Presenhl~N)
Date of Last Adequacy Test
!
To Water-Supply Well
To Building Foundation o~O I '~'
Lot ~/~
To Water Main/Service Line ,~o ~£
To Stream/Pond/Lake/or Major Drainage Course
To Driveway, Parking Area, or Vehicle Storage Area
To Property Line
To Existing or A~andoned System on
; On Adjoining Lots ~o
To Cutbank (if present)
Comments
D. LIFT STATION
Date Installed
Size in Gallons
"Pump On" Level at
High Water Alarm Level at
Tested for
Dimensions
Manhole/Access (Y/N)
"Pump Off" Level at
Vent (Y/N)
Pumping Cycles during Adequacy Test. Meets MOA
Electrical Codes (Y/N)
Comments
** Check Permitted Bedroom Rating Against HAA Request **
I certify that I have checke, d~y.e, rj.fied, or conformed to all MOA and HAA guidelines in effect on the date of this inspection.
Signed . -~B 1~__~... Date // / "/'
Company PR. 6oj4-2379 MOA No. ~r"O --,.C,,-O ~, '
Receipt No.
Date of Payment '") - ~ '') - ~>~-'
Amount: $
Page 2 of 2
72-026 (I 1~84)
DEPT. OF ENVIRONMENTAL CONSER%ATION
ANCHORAGE/WESTERN DISTRICT OFFICE
437 "E" STREET, SUITE 303
ANCHORAGE, ALASKA 99501
BILL ..~H£FFIELD, GOVERNOR
Telephone: (907)
Address:
274-2533
To Whom it May Concern:
Accord~g_t~o r, ecords on file in this office the~F'~__U~(.~. .
(/~,~~Water Systemis in compliancewith the State Drinking
l~at~r--'Regulations
Sincerely,
~r~ MUNICIPALITY OF ANCHORAG~
DMSION OF ~%%r1~ HEALTH
DEPAErMENT OF HEALTH AND f~5;I~ P~OTECTION
APPLICATION FOR HEALTH A[3THORITY APPROVAL ck'RTIFICATE
1. General Infc~mation
Application Date ..4/5/84
(a) Legal Description (include lot, block, subdivision, section, township, range)
Lot lOB, Eagle River Valley Ranchettes, Sec.. 7, TI4N, R.)W. Eaole River. AK
Location (address c~ directions)
169 Crestview Lane, Eagle River, AK 99577
(b) Applicants Na~e Jeff Ayres Telephone 694-4~
Applicants Address 169 ~restview Lane. Eagle River. AK 99577
(c) Applicant is (che~k one) Lending Institution F--]; Owr~r/9~~-I;
Buyer ~ ; Other F~I (explain);
(d) Lending Institution N/A Telephone
Address
(e) Neal Estate Co. & Agent N/A
Address ."
Te le Phone
2..~ of Besidenee
Sir~31e-Family
Number of Bedrooms
3. Water SuDpl~'
M~lti-Family[---~
3
Other (describe)
Individual Well [-~ C~,lunity ~ Public
Note: If ua~.~nity well system, must have written confirmation from the State
Department of Environn~ntal Conservation attesting to the legality and status.
Is the well adequate for the number of bedrooms specified in this HAA (Y/N) Yes
4. Sewage Disposal
Is the wastewater disposal system adequate for the 'm~mber of bedrooms
[Page 1 of 2]
2-15-84
Se
Engineering Firm .Prov~dirg Inspecticr~? Tests, Data and Infr~.'.aticn
'I oertify that I have c~cked, ~rified, c~ c~nfczT~d to all MgA HAA Guidelines ~Ln
effect on the date of this inspectic, n.
Name of Firm A.W. Nurfitt Co. Telephor~ 349-7531
Adcl~ess 8010 Ki.ng St., Anchoraqe~ AK 99502
Signed by Keven K. Kleweno
Date
(ENGn~m~R SEAL)
6. D~EP A~proval
Appro~d for 3 bedrcc~s
Terms of Conditionml ApUroval
Cc~diti~l [-~
The Municipality of Anchorage Department of Health and Envirc~,:ntal Prctection dces
nct guarantee the' cc~.tinued satisfactory ~erfc~manoe of the water supply and/ct the
wastew-ater disposal system. This apprc~ral indicates that, as of the validation date
shoma abc~, based or1 the data and infcrmation furnished ky an emgir~er registered in
the State of Alaska, the w~ter supply and w~stewater disposal system is safe add func-
ticr~l fc~ the mm.her of ~edroa~ ~nd type cf structure indicated.
(D~EP SEAL)
7. Mail the HAA to the following address:
Jeff Ayres
169 Crestview Lane
Eagl~ River. AK 99577
KB /dS/s
[Page 2 of 2]
F~: Jeff Ayres
169 Crestview Lane
· Eagle River, AK 99577,
kot
Eagle'River Valley Ranchettes
Sec. 7, 714N, R1W
Eagle River, AK
A. ~Fr.T. DATA
MUNICIPALITY OF ANCHORAGE (MQA)
HEALTH AUTHOPJTY A~PROVAL (HAA)
CHECKLIST - FEBRUARY 1984
Well Classification A If A, B, cr C, D.E.C. App=~d(Y/N) YES
Well Log Present (Y/N) Date G~{>leted Yield
Total Depth Cased to Depth of Groutin~
Static Water Leal Pump Set At
Casing Height Abo~ Ground Sanitary Seal on Casing (Y/N)
Electrical Wi=ing in Conduit '(Y/N) Depression Around Wellhead (Y/N)
Separation Distances f=~ Well:
To Septic/Holding Tank on Lot ; On i~djoining Lots
To Near~st Edge of Absorption Field on Lot ; On Adjoining Lots
To Nearest Public Sewer Line To Nearest Public Se~r
Cleanout/Mar~ole To Nearest Se~r Service Line,on Lot
Water Sample Collected By ~ Date
Water Sample Test Results
C~,,=nts C0m~unity well in compliance with DEC regulations
B. SEPTIC/~LD~[~ TANK Ii~TA
Date Installed 1977 Size 1000 gal. No. cf Ccmpartments~ ?
· '/es
Standpi. pss (Y/N) Yes Air-tight Caps .(Y/N) Yes Foundation Cleanout (Y/N)'C0mment:
Depression OUr Tank .(Y/N) No Date Last Pumped 3/25/84
P,~,~ping/Maintenance Contract on File .(Y/N) N/A ; for
Holding Tank High-Water Alarm (Y/N) N/A Temporary Holding Tank Pe£mit (y/N)N/A
Separation Distances fzcm Septic/Holding Tank:
To Water-Supply Well 2000 ft.
To Property Line 35 ft..
To Water .Main/Service Line 20 ft.
Course N/A ~
To Building Foundation 10 ft.
To Disposal Field 10 ft.
TO Stream, Pond, Lake, cr Major Drainage
Ccrm"ents Foundation cleanQut in crawl space under house
[~age 1 of 2] 2-15-84
ABSORPTION FIELD raTA
Soils Rating in Absorpticn St.~ata
Date Ir.~talled 1977
Width of Field Unknown
Square Feet of Absorption Area 450 ft2
Depression over Field (Y/N)
150 ft2/br Type of'System Design Trench
[ength.~of Field 25 ft,
Depth of Field Unknown
Gravel Bed Thickness
Standpipes P~esent .(Y/N) Yes
Date of Last Adequacy Test 3/30/84
Results of last ~quacy Test Adequate for 3 bedrooms (§00+ §pd)
Beparatio~ Distanc~ f~a~ AbsCrPtic~. Field:
To Water-Supply Well 2000 .ft. TO P~operty Line 35 ft.
To Building Foundatio~ 20 ft. To Existing or Abandoned System cn
Lct N/A ; .On Adjoining Lots 100 ft.
To Water Main/Servioe Line 30 ft. To Cutbank(if present) N/A
To Stream/Pond/Lake/c~ Major Drainage Course ['I/A
TO Driveway, Parking Area, or Vehicle Storage Area 80 ft.
Ccmments
D. LIFT STATION
Date Ir~talled N/A
Size in Gallc~s . N/A
"P~,~ On" I~vel at N/A
High Water Alarm Level at
Tested for ~I/A
Electrical Codes(Y/N)
Ccnments
Dime r~ ic~.s N/A
Manhole/Access _(..Y/N ) N/A
"P~,~ Off" Level at N/A
Vent (Y/N) N,/~
Pumping Cycles ck~ir~ Adequacy Test.
** (~eck I~rmitted Bed~ocra Rating ~gaimst HAA l~equest **
I-c~rtify that I have checked, verified, Or cc~fc~med to ell MOA
on the date cf this ir-~pect.ic~,.
Cc~any A. W. Nurfitt Co.
/~ W. MURFITT COMPANY
~:m./dS/~ Allen ',~;,. ~:~,,,,r,." - ' ",' P.E.
¢,,~,: :" r, t
(907) ~49-7531
2-15-84
in effect
DEPT. OF ENVIRONMENTAL CONSERVATION /
BILL SHEFFIELD, GOVERNOR
rexephone: I~o7) 274-2533
Address: 437 E. Street
Suite 200
Anchorage, AK
99501
April 6, 1984
To Whom It May Concern:
According to records in this office, Eagle River Valley Ranchettes Water
System is in compliance with the State Drinking Water Regulations.
Sincerely,
JFH/msm
cc: A.W. Murfitt Company
Jeff Ayers
801 King Street
Anchorage, AK 99502
I hereby certify that a .survey of Lot Ibl~ , Block
Subdivision was made on /v~3,-¢~ {~4 and
that the improvements situated thereon are within the property lines
and do not overlap or encroach on the property lying adjacent thereto,
that no improvements on property lying adjacent thereto encroach on
the premises in question and that there are no roadways, transmission
lines or other visible easements on said property except as indicated
hereon.
Dated at Anchorage, Alaska, this day of ~v\~.~-r,,~
CONSTRUCTING'ENGINEERS, INC.
SRA Box 60, Anchorage, Alaska 99507
3444)817
A ,~lvil and Geotechnicai Engineering Consu)~'"~?
April 5, 1984
Jeff Ayres
169 Crestview Lane
Eagle River, Alaska
Re:
A.W. Murfi'tt Company_
8010 King Street · Anchorage, Alaska 99502
Telephone (907) 349-7531
99577
Adequacy Test for Existing Septic System
Lot lOB, Eagle River Valley Ranchettes Subdivision
Section 7, T. 14 N., R. 1W.
Eagle River, Alaska
Dear Mr. Ayres:
Pursuant to your request on March 20, 1984, we have completed an adequacy
test at the above referenced site.
In accordance with the Anchorage Municipal Code, Chapters 15.65, Waste
Water Oispos~l Regulations, any on-site sewage disposal system, "shall
have adequate capacity to properly dispose of the maximum daily sewage
flow." The maximum daily flow is computed at 75 gallons per day (gpd)
per person. 'Since "the population of dwellings shall be estimated at
two persons per sleeping room," the maximum daily sewage flow for your
three (3) bedroom house is 450 gallons per day
To test the soil absorption capacity as well as the surge capability of
your system, llO percent of the maximum daily flow or 500 gallons of
clear water was added in 50 gallon increments to the leach trench. The
water was obtained from your outside tap at its maximum sustained rate
of about three (3) gallons per minute (gpm). The liquid levels were
monitored closely from the two (2) leach trench standpipes and the
septic tank standpipe to detect any back-up in the septic system. In
the interest of safety, the septic tank was pumped prior to the test.
On the first day of the test after adding 500 gallons of water to the
leach trench, no noticeable rise in the liquid levels was noticed in
either of the two (2} leach trench standpipes or in the septic tank
standpipe. On the second day after adding 280 gallons of water to the
leach field, no noticeable rise in the liquid levels was noticed. At
this time we discontinued the test, as trw as apparent that the system
was accepting the water at a rate greater than the design rate of 450
gpd.
Based.on two days of testing, a percolation rate for your existing
septic system of greater than 500 gQd is indicated. Since an on site
sewage disposal system for a three (3) bedroom dwelling must be capable
of disposing of 450 gallons of sewage per day, your septic system appears
tO be functioning very satisfactorily at this time.
Jeff Ayres
April 5, lg84
Page 2
We appreciate this opportunity to be of service to you. Should you have
any questions regarding this matter, please do not hesitate to contact
US.
Yours truly,
Keven K. Kleweno, E.I.T.
Staff Engineer
Allan W. Murfitt, P.E.
Civil En.qine~r 4977-E
C---? 'A'PPLI~'~.NT FILLS OUT UPPER HA'~.~ONLY
Property Owner ~-'OLC..t)[~ ~ ~< ~, ~ / Phone
Lendinglnsti~tlon ~ ~'0~1 ~Jo+ a~~ ' .~)~ Phone
LegalDescrlpt~n ~' ~O -- ~ ~0J~ ~ ~(~y ~~ '..,
Type of Resl~nce
~ Single Family ~ ~ ~ ' -'"
~ Multiple Family No. of Bedroo~,~ '~',,
~ Other ',
Water Supply
Individ~l A~ACH ~LL LOG. A w~l log Is requlr~ for all wells drlled since June 1975.
Comm~ity For wells ~111~ prior to that date. give well depth (att~'log If available).
~ Public Utility
r Disposal "" '
Individ~l Year IndivUual Installed: '
~ Public ~llity When Co~ect~ to Public Utility: .'--' ' '
~ Holding Tank
NOTE: THE INSPECTION ~E MUST ACCOMPANY EACH RE~EST BEFORE ~OCESSING CAN BE INITIATED.
Time Time Time Time
Io ,. '''
Inspector Inspector Inspector Inspector
Field Notes:
/Vo.~/,,,~ ,~ ?.7'? ~ APR 1 5 1983
~ t'""'li!'~- 5" ... ,..
( ) APPROVED BEDROOMS 'CONDITIONS OF
I-/~ DISAPPROVEDJ~l IEI~V~,~ (~',~,..,,.-~1
(
( ) CONDITIONAL APPRGIVAI..~
DATE ·
Soils Rating Date Sewer Installed Well To Absorption Area Well Log Received
Well to Tank Septic Tank Size