Loading...
HomeMy WebLinkAboutARANT LT 1A an? Lot I #015-163-71  Municipality of Anchorage o Development Services Department '~'~'~----~' Building Safety Division ~-'-'=':-- -;~-~--"' On-Site Water & Wastewater Program, 4700 South Bragaw St.'.--- .~_'" = "~: P.O. Box 196650 Anchorage, AK 99519-6650 '~ ~ www.ci.anchorage.ak.us (907) 343-7904 Page 1 of On-Site Wastewater Disposal System and/or Well Inspection Report Permit Number:. SW020052 PID Number:. 01 5--1 63--71 Name: RANDY KANADY Wastewater System: B New I-1 Upgrade 2350 COPPERWOOD DR. 99518 ABSORPTION FIELD Phone: No. of $edrooml: (907) 348-8843 3 ODeep Trench WShallow Trench I'lBed rlMound rlOther LEGAL DESCRIPTION = "~ 1.2 ~'~/s~ r~ ,.~ ~.m ,~'~ ~ ~,~5.31 - 1 ARANT 4.86 MAX ~ 4.14 n. Townlhlp: Range: Section: ~ ~ ~ ~ ~ae: ~ ~ - - - SEE DWG ~ 60 WELL: B New I-I Upgrade 5 ~. 1 - 04~dfloa~ (~',~.~',~, ~B.C): Teed ~ Cored Tm Teed a~mq~e~ ~ POe PRIVATE 267 ~ 125 ~ 600 se.r~ D 3034/ F-810 ALPINE DRILLING 5/15/02 0 ,. RED DOG MASONRY 6-29/2002 1.75 ~'~ UNK ,~ 1.5+ ,, TANK SEPARATION DISTANCES .S..Ua OUoldlng OS.T.[.P. OOthar To Septic n Uft Nolalng Tank Station Tank ~ U~. ANCHORAGE TANK 1000 Well 100'+ 100% - - 25'+ STEEL 2 Surface Water 100% 100% - - - LIFT STATION Remarks: BENCH MARK BOTTOM OF SEPTIC TANK 89.40 Inspections performed by: AKWWC, INC. Dates: lSt2nd 4/26/20024/26/2002 :-'~;~X,~ '/ 3rd 4/29/2002 ,~.~,[~;f, ~ %." !. ' Development Se, Vices Department Approva,/~!e_~ ~l~t~,~:': ~.,L. ....... PERMIT NUMBER: AS BUILT D RAWIN G PARCEL ID NUMBER: SW020052 m 015-165-71 I I , ST1 43.61 55.21 '-I I z-.I j ST2 48.67 59.00 'ml~.-....-,~'~l I I I I ~ '"- ~ DEL1 50.63 60.43 I I I DEL2 .51.88 61.33 I I I I I I' ~DSL~ / COl ~9.Ol 55.s2 I [[ tt :'/. / I co~ ~o~.~ ~o..o~ I ~ ~ ,,~ / MT2 105.07 106.46 ~- __ ~ ~12J ~ll / ~ I~ Ho ~ I~ .~ ~ooo ~o~ / I ~ o. . I , ........ .) ~.., ~ .............. .~ ,~J'... ,~' 'B ST1 43.61 55.21 ST2 48.67 59.00 DEL1 50.63 60.43 DEL2 51.86 61.33 C01 49.01 55.62 MTI 50.99 56.99 C02 107.55 109.03 MT2 105.07 106.46 DRAWN BT: ALASKA WATER & WASTEWATER c.J.O. , CONSULTANTS, INC. se.~u:: ~R£PARED FOR: PHONE NUMBER: PAGE NUMBER: RANDY KANADY (907) 348-8845 2 OF LEGAL DESCRIPTION: ARANT SUBDIVISION; LOT 1 TYPE OF WORK: AS-BUILT DRAWING OF NEW SEPTIC SYSTEM ~[~,~ ~o,~R: AS BUILT DRAWING SW020052 -- 015-163-71 TOP OF TANK AT~ =~ ~ G~DE = ~ 98.27+ ~TOP OF TANK AT AT IN~ - 93.71 j ~ 0~ = 93.43 TH~I / ~ II "' I - ~s.os (~v,.) / . ~S~ WATER & WASTEWATER ~: , CONSULTANTS, INC., ................... ~ ~o.: ~.o~ .~.: ~ .u~.: ~:~ ......... .~ RANDY KANADY (907) 348-8843 ~ D~CRI~ION: ARANT SUBDIVISION; LOT 1 "' ~E OF WORK: PROFILE AS-BUILT DRAWING OF NEW SEPTIC SYSTEM Municipality of Anchorage Department of Health and Human Services 825 'L' Street P,O. Box 196650 Anchorage, Alaska 99519-6650 Rick Mystmm http://www.ci.anchorage.ak.us '. . ,* Mayo~ - .. .......... Permit Number: #SW 020052 Date of Issue: .4-8-02 Date Started: 5-15-02 Date Completed: 5-16-02 Legal Description: Arant Lot I . . Property Owner Name & Address: Randy Kanady 2350 Copperfield Ddve Anchorage, Alaska 99516 Borehole Data: Depth (ft) Method of Drilling [] air rotary Soil Type, Thickness & Water Strata From To stick-up 0 2 silty gra vel 2 15 gravelly silt 15 36 silt 36 41 ga velly silt 41 88 silty water sand & gravel(3gpm) 88 91 silt 91 100 gravelly silt 100 116 siltywater sand & grave (15gpm) 116 119 silt 119 125 Bedrock 125 267 131 131 240 244 small seepage (.25 gpm) fracture (1.5gpm) total depth , 267 Parcel Identification Number: 015-163-7 Is well located at approved permit location? [] Yes [] N [] cable tool Casing type: stoel Wall Thickness: ..250 inches Diameter: 6 inches ' Depth: 1_25 feet Liner Type: ~ Diameter: .inches Depth: ~ feet Casing stickup above ground: _2 feet ' Static water level (from ground level): O_.feet Pumping level: 267 feet after _2 hours pumping 1.75 gpm Recovery Rate: 1,75 gpm .. · - '.' . - Method of Testing: airlift . Well Intake Opening Type: [] Open End [] Open Hole [] Screened Start ~ feet Stopped ~ fcc [] Perforations Start ~ feet Stopped ~ fcc Grout Type: Bentonite granules Volume: I b; Depth: · StartO feet Stopped: fe~ Pump: Intake Depth feet Pump size ~ hp Brand Name ~ Well Disinfected Upon Completion.* [] Yes [] I~ Method of Dislnfection: chlorine tablets Comments: Well Driller: Alpine Ddlling & Enterprises PO Box 110496 Anchorage Alaska 99511 Attention: The well driller shall provide a well log to the property owner within 30 days of completion and thc property I'It~E-18-2003 TUE 03:16 Pti UtNTECH/SI~'I~ FttX NO. 9075816626 P. O! z I i~ ~ LOT 1 m % $ ~ LOT 2 ~ ',v"v.'"v. .... .'.'.'.'.',','.w.'.'.'.'.','.~' ~'.v,'.. '.V.'. KLATT ROAD  ph~lC~ ~ND ~ CONST~UC~N 5UR~YO~S-~NNERS-~G, NEERS 440 ~ST ~ENS~ ~L~, ~ 103 (~) _- --,,.~-., ~ ,~.~ ARANT SUBDIVISION Post-lr'raxNole ?67)'.~,f°a~~'~j~j I~I' / MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM / WATER SUPPLY PERMIT Initial Date Issued: Apr 08, 2002 Expiration Date: Apr 08, 2003 Permit Number: SW020052 Legal Description: AP, ANT LT 1 Design Engineer: 0041 AK Water & Wastewater Consultan' Owner Name: Randy Kanady Owner Address: 2350 Copperwood Dr. Total Bedrooms: 3 Anchorage, AK 99516- Parcel ID: 015-163-71 Site Address: Lot Size: 40360 SQ. FT. Permit Bedrooms: 3 This permit is for the construction of: [] Disposal Field [] Septic Tank [] Holding Tank ~ Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date:, Date:~_~O~- Municipality of Anchorage Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 Parcel I.D. ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING viP'-lb-3 -'? [ Permit Number Property owner(s) Mailing address (1) Mailing address (2) Legal description (Lot, Block & Sub'd.) LOT 1: ARANT SUBDIVISION Legal description (Section, Township & Range) Lot Size /-'//~ ~ Acre~'~a.Ft~'.), THIS APPLICATION IS FOR: Sewer Only. Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool RANDY KANADY 2350 COPPERWOOD DRIVE * ANCHORAGIZ. AK N/^ Number of Bedrooms Dayphone 830-0742 Zip Code 99516  , Well Only ~ Water Storage [] Jacuzzi [] Water Softening Unit I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal codes. ALASKA WATER & WAST~WATER CONSULTANTSr INC. Permit Fees:~ 5 Date of Payment: Receipt Number: Waiver Fees: Date of Payment: Receipt Number: ALASILA WATER & WASTEWATER CONSULTANTS, INC. ' ..... ~" March 20, 2002 Municipality of Anchorage Development Service Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragraw Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Reft Proposed and Well Septic System Design for Lot 1, Arant Subdivision To whom it may concern: The proposed 3 bedroom house will be served by a private well and septic system. Two test holes were excavated in the area of the proposed septic system. The septic system will be designed around the 30 foot radii of these test holes. We are proposing that a 1000 gallon septic tank and a five foot wide drainfield be installed with a grinder pump in the daylight basement. The well is to be drilled in the location shown on the site plan. Comments regarding the design are summarized as follows: 1. SOILS: See the attached logs which shows the soil classifications, groundwater monitoring, and the percolation test results. It is our opinion that an application rate of 1.2 gallons/day/ft2 should be used. 2. TRENCII DESIGN: a. Percolation Rate: 2.2 & 5.0 minutes/inch b. Allowable Application Rate: 1.2 gallons/day/ft2 c. Number of Bedrooms: 3 d. Design Flow: 600 gallons per day e. Minimum Absorption Area: 500 ft2 f. Total Depth: 10 feet (max.) g. Effective Depth: 4 feet h. Width: 5 feet' i. Reduction Factor: 0.50 j. Minimum Length: 60 feet long k Effective absorption area -- 600 ft2 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwxvc.cora 3. SURFACE WATERS: There is a drainage ditch with a intem~ittent stream running along the west property line. The 100 foot setback will be flagged by a registered land surveyor prior to construction. 4. TOPOGRAPHY: The area for the proposed septic system is a 10% to 20% slope running east to west. Them is a slope ofapproximately 31% roughly 40 feet from the proposed drainfield. We request that a waiver be granted to 35 feet. The doxvnhill side of the cut bank is heavily vegetated which should inhibit any surfacing of effluent. Given the percolation rate of the soil the effluent should have rapid downward movement and minimal lateral migration. We see minimal risk in granting the 35 foot waiver to the 25%+ slope. We are unaware of any adverse impacts this installation would have on adjacent wells or septic systems. If you have any questions, please contact us at 337-6179. Thank you for your assistance. ~ Sincerel~ NOTE: Attacl~ed is a site plan drawing, a design drawing, two soils log, a topography site plan, and a 7 page construction specification letter which are all part of the design package for this septic system. 6901 Debarr Road, Suite 2B * Anchorage, AK 99504 Ph: (907) 337-6179 * Fax: (907) 338-3246 * Website: akwxvc.com > ~mOt-ES ON / I I l ~. NORTH HALe / t I ¢ I (~PROX. LO~ON) I I I I I ,, J 0M ~ ~SCH~-- j (s~ I ,, I i ~PROPOSED ~/ J BROWN S/D; I I I ...... I I ~ I j I ~ K~ ROAD I I PROPOS~ ~ I 3 B~ROOM J SUN~ S/D; HO~E b I ' CONSULTANTS. INC. 1" PR~ED FOR PHONE NUMBER: PAGE NUMBS: RANDY KANADY ~48-884~ 1 LOT 1; ARANT SUBDIVISION SITE P~N FOR PROPOSED WELL AND SEPTIC SYSTEM LOCATION I i /, NOTE: THE CONTRATOR SHALL HAVE / I ~ , I - J THE 100 FOOT SETBACK FROM ! ~ _ ~ / I DRAINAGE DITCH. THE NEIBHORINO~ / ! rP~ '~ I / J WELL RADIUS, AND THE EAST LOT / I ._J_ i ' J,~ . / J UNE FLAGGED BY A REGISTERED ! / ~ MsJ~ i F~v,"I I / J LAND SURVEYOR PRIOR TO / J I I.~, j /~ '. ~ m J CONSTRUCTION. '/ ~ ! .I~ i'J J ''~ I~---AL1TrmNATESlTE / I !! .~ ii ' /~ Wi,, f J : I I ~- i i ~ / I U~T STATION J ~ i~.! ' ii/J~ '/ J P~oPosa) ~R~N~. ~XC~VAT~ ^ ~mC, j ! '! ~ , THAT S 10 EEl' DEEP I~Ug(~UM m' 5 I-L~.t I ~ ~ I I , , I I WIDE ~ 80 FI~£I LONg. N:)D 4 ~J~.l OF ~ I I I J ,, I ' CLEAN WASHED SEWER ORNNROCK. INSTALL J J J 1 I I '~ INSTALL DOUBLE , ~ ~ ~ ,. c~~o., ~ , , ~ xx, .I I ~ ~ [~t(..,:~ NOTE: A GRINDER ~l J , ~~- ~h~..:-~ ~[~ PUUP TO BE I ~ ~ ~ ~' ~ '.'TZ~ IN~ALLED IN ~E ~ 5 ~ ~~~-~'-I' I :~ A~S~ XI~TER & ~STEII~TER ,~ RANDY KANADY (907) 348-8843 2 OF 2 '" ~ D~C~.: ~0~.~"'. ~ ,~-~953 ..'".~ LOT 1; ARANT SUBDIVISION DESIGN OF PROPOSED WELL LOCATION AND SEPTIC SYSTEM UPGRADE ........................................................ ALASI WATER & ASTEWATER LEGAL DESCRI~ION: ~ SUBD~SION: LOT 1, ~[r~ ORGANICS ITEST HOLE ~1 I ,~OIL C~SSIRCATION$ OH I I DEPTHTO ~ ~ ~ ~ x~ } ~C.,NC GROUNDWATER ~ DATE / 5/21/2002 t GP/SP CLOCK NET TIHE WATER LEVEL NET DROP ,1 ~{j~ TO GM/SM DATE READING TINE (NINUTES) READING (INCHES) 12~i~ ~ ~/15/2002 I 10:54 - 6- _ 2 ~o:44 ~o · 15 3 10:44 - 6- - 14 5 10:54 - 6- - 6 11:04 10 '1 1/2" 4 1/2' 15 7 11:04 - 6- - 9 11:14 - 6- - ~8 12 ~1:~4 ~0 ~ 1/2' 4 ~/2" 19 PERCOLATION RATE 2.2 (HIN./INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN 6.0 FT. AND 6,5 FT. 20 A FOUR HOUR PRESOAK WAS PERFORHED: ~ YES ~ NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORHED BY: ~B GALL COHHENTS: PERFORMED BY A.W.W.C., INC. I, ~EFFR~ A. G~NESS, CERTI~ T~T ~IS ~/PERFORMED IN ACCORD~CE WITH ~L ~ATE AND MUNICIPAL GUDEUNES N E~ECT ON THS DA~: I DEPTH TO DATE GROUNDWATER Dm' J~/14/2oo2 DRY 5/15/2002 ,Dry 5/21/2002 ALASIL& WATER & 'VASTF. WATER~ i~[ "..'..~;/S' ~ i'i.....v..<!! ..... ..... 6901 Dq. BARR ROAD,~UITE 28 * ANCHORAGE. AK. 99504 · PHONr' (907),~7--elIg * FAX: (g~I~5,,xS-3246 · WT. BSE~ okwwc.com ........ , ...... JSOIL LOG - PERCOLATION TESTI PERFORMED FOR: RANDY KANADY DATE: 3,/14/2002 Oh .'"' ~fEePet~ ~ ORGANICS ITEST HOLE #21 -~'~.~'"-' 1-- $01k CLASSIFICATIONS t, .................... J ~ .HOLES J I ~ LO¢CrD BY ~ J 3 ........ GcGPII .~..~. MLoL GH CL z ~ I ~_. 4-- , / I SW I NH ./i PROPOSED 5- -----, SP CH ~; ~ , ~ED~oou s~ I o. TO GM/SlVl .q ..x . // DEPTH TO I -Aw'wa, IN~ GROUNDWATER DATE x ! , I, ., /,,v2oo2 ,, ,,. DRY 3/15/2002 II 9- Pr'), ~/21/2002 ''~ ' t srrE pLANL. t 1"~100' 10-- 11 DATE READING CLOCK NET TIHE WATER LEVEL NET DROP -- TIHE (HINUTES) READING (INCHES) 12 -- 3/15/2002 1 10:33 - 6- _ 2 10:45 10 4' 2' 13-- ~.~.~,e. 5 10:45 - 6- - · .~.~ ,~ o 4 10:55 10 4" 2' 14-- " "~ · :.~=:,. · 5 10:55 - 6' - ~'"' cP/SP :-~;;~ ·, · 6 11:03 10 4' 2' 15 -- :~:~.".,e · ~,~,, · 7 11:03 - 6- _ .~,:<e. ~- 8 11:13 10 4' 2' ~'*' · ' 9 11:13 - 6" 17-- ~ 10 11:23 10 4" B.O.H. 11 11:25 - 6" _ 18-- 12 11:33 10 4" 2' PERCOLATION RATE 5.0 (MIN./INCH) PERC. HOLE DIA. 6 (INCHES) 19-- J TEST RUN BETWEEN 6.0 FT. AND 6.5 FT. 20-- ~ A FOUR HOUR PRESOAK WAS PERFORMED: · YES [] NO SOILS LOGGED BY: JODY MAUS PERCOLATION TEST PERFORMED BY: .. CALEB GALL COHHENTS: PERFORMED BY A.W.W.C., INC. I, JEFFREY A. CARNESS, CERTIFY THAT THIS'y/AS/PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL CUIDEUNES IN EFFECT ON THIS DATE: DEPTH TO GROUNDWATER DATE DRY 3/14/2002 DRY 5/15/2002 ~r'~ 3/21/2002 '1 LOT 2 £AVE LiNE 5001 ~,.~ '.. IS-B202