Loading...
HomeMy WebLinkAboutMUIRWOOD PARK BLK 4 LT 8Muirwood Park Block 4 Lot 8 #011-422-85 '-.:;'" '~ Municipality of Anchorage Page ! of 3 Development Services Depadment On-Site Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ct.anchorage,ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: SW020344 PID Number: 011-422-85 Crown Pointe, Inc. WastewaterSystem: New AddreSs: 5400 Abbott Road Anch. AK 99507 ABSORPTION FIELD 345-6277 Five (5) Deep Trench LEGAL DESCRIPTION 1.2 o,o~¢ 3.0 4 8 Muirwood Park 3 F,. 7 3. F,. 46 F~. Well: Municipal Water System c~a,~,.~m: 3 Ft. mmb.~o.,.es:3. [[~st~ b~,..~,..:. Ft. Ft.644 Ft' ASTM D3034 PVC Ft. Sanders & Sanders 9/3.7/2002 yin.: ~PM [ Pump Se, at:Ft. [ c.~.g, ..g., Ado.,. ~.r.~:F, TANK SEPARATION DISTANCES E3 Septic [-I Holding [-I S.T.E.P. [~ Other: T.~'~...j_oI Septic Absorption Lift Holding ~ublic/Pfivate ManufaCturer; ~apac~t¥ Tank Field Station Tank S~,~rU~, Anchorage Tank 3.,500 w.,, >200' >200' N/A N/A >25' Steel Two (2) ~tu.,s"""~' w~t., >3.00'>5, >3.00'>3.0, N/AN/A N/AN/A ~/ ~,.~: LIFTc.,,.ISTATION~'~'~'"'~'~ - NONE ON LOT F~,.~.,,o. >5' >3.0' N/A N/A /~ '"'""'~'~'~": I''~'""°''''~"'''': ~,. cu~.o.~. None Noted PumpMake&Moael ElectnCallnSpecl~onspedormeclby: .e.,~: BENCH MARK Southwest Corner Deck at Front Door. 100.0 Ft. Engineer's Stamp ?K~/' :,..~' ............ ,.' ~.:.." A '"....~,', Inspections performedby: MEA Dates: 1't 9/3.7/02 ff~.[ 49th. "~ ~'A: 2"~ 9/17/02 ,~.~.c~^r~r.,~:r,so~ ~. Department of Health and Human Services approval *,~.O~.r..o', No c[-4381 *. ~'~'. ....... ~,~- Reviewed and approved by: ~_~'_~? Zt/, ~t:~Tt~Date:_J'~-/Z//- O~ '.-~'o... ,~.; .~.... ................. Permit Number:. SW020344 Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bmgaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report N 90'00'00"E 167.19' Page 2 of 3 PID No. 011.425-85 00 0 S1 S2 C4 C5 M1 A B 22.3 23.2 15.3 24.7 55.2 16.5 70.6 61.1 59.1 21.5 FIVE BEDROOM HOME -91 S2 C4 aISlteltern°te ¢5 30' Z 10' BUFFER LANDSCAPE ESMT. N 90'O0'O0"E 146.50'' KINCAID ROAD ~.~.,c.~ PLAN AS-BUILT ......... Municipality of Anchorage - DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On-Site Wastewater Disposal System or Well Inspection Report Permit Number:SW020344 Page 3 of 3 PID No. 011-422-85 83.7/ 171.;) :r;, BACKFILL ..... ~eotext~le F,b~ic 97.7j Br ,,inFie{,d Rock '37.7 / , 90.7 80.5 46' T~en~h Length PROFILE AS-BUILT Scole: I" = 10' MUNICIPALITY OF ANCHORA GE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Date Issued: Sep 13, 2002 Expiration Date: Sep 13, 2003 Permit Number: SW020344 Legal Description: Muirwood Park Block 4 Lot 8 Design Engineer: 0014 Anderson Engineering Owner Name: Crown Pointe, Inc. Owner Address: PO Box 112313 Anchorage, A 99511- Parcel ID: 011-422-85 Site Address: nhn Lot Size: 40001 SQ. FT. Total Bedrooms: 5 Permit Bedrooms: 5 This permit is for the construction of.' [] Disposal Field [] Septic Tank [] Holding Tank [] Privy [] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: Date: Parcel I.D. Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St, P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/VVELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Permit Number SW 0Z0~44~ Properly owner(s) Crown Pointe, Inc. Mailing address (1) P.O. Box '112313 Anchorage, AK 99511 Mailing address (2) Zip Code Legal description (Lot, Block & Sub'd.) Lot 8, Block 4, Muirwood Park Subdivision Legal description (Section, Township & Range) Lot Size 40~001 SF THIS APPLICATION IS FOR: Sewer Only Sewer and Well Sewer Upgrade THIS PROPERTY CONTAINS: Hot Tub Swimming Pool Therapy Pool Acres/Sq.Ft. Number of Bedrooms Five (5) Day phone 727-8167 I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Receipt Number: (Rev. 12/00) Waiver Fees: Date of Payment: Receipt Number: [] Jacuzzi [--I [] Water Softening Unit [] [] Well Only [] [] Water Storage [] t, ; ! ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 .. 522-6779 (FAX) . September 3, 2002 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 8, Block 4, Muirwood Park Subdivision Septic System Design and Permit Application Impacts to Adjacent Propedies Dear Onsite Services Engineer: The owner of Lot 8, Block 4, Muirwood Park Subdivision intends to construct a five- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new septic system to serve the home. The lot is currently served by the Municipal water system. The attached Site Plan and backup documentation identify the location and configuration of the new septic system and the parameters used in the design. Also identified on the plans are the water service location, test hole locations and the locations of the existing wells and systems on adjacent lots. Drainage arrows are also shown and current drainage patterns will be maintained after construction. The test holes placed near the location of the proposed and alternate absorption trenches indicated fairly clean well graded to poorly graded sand varying amounts of silt and a percolation rate of 2 to 5 minutes per inch in the accepting layer. We are therefore proposing to construct a deep absorption system with a 3' wide by 45' long trench with a 7' effective depth. The distribution piping depth will be 3' below the surface. Total depth of the trench will be 10'. The ground surface on the lot slopes as shown on the attached Site Plan with 2% to 3% slopes from west to east. The new septic tank and absorption trench will be constructed parallel with the slope in conformance with Municipal requirements. All components of the new septic system will be constructed a minimum of 10' from the water service line on the lot. The system will also be constructed a minimum of 100' from any surface water in the area. If the system is constructed in accordance with our design the following statements apply: The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. The subdivision is currently served by the Municipal water system. Lot 8, Block 4, Muirwood Park September 3, 2002 Page Two The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area, The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Michael E. Anderson, P.E. Attachments SCALE 1" = 100' 49th This VACANT 7 I I I ! -' 32.18'.: ":VACANT "' '.' ". N90'00'00"£ ...... , 238.5(" i / '" NOO'OO'OO"W 485.01'""(R&~M) ' ". k 'x~ .,~,,~.,.C,'.,;'.'C.:.,::: \...,0o. ..... =: .......... KINCAII~ 'R~3A~D '" O --~. ', FROM ASSUMED DATUM (TfP) RELATIVE ELEVATION N gO°OO'OO"E 167.19' [ZIS~ING & PROPOSED DRAINAGE PATI£RN .I I .I TH2 / 5.0' / 45.0' / iX 101' FIN. FLR. EL. = 103' A.C. DRIVE Five Bedroom . ]~ome .,'z.~. .~ £NTRY 32.0' 10' 1,500 ,Gallon Septic Tank 45' Long x 3' Wide x 7' Effective Depth 10' BUFFER LANDSCAPE £SMT. · ~o' u~u'~s~. L~ i3o' E! · N gO°OO'OO"E 146.50' 'SITE PLAN SCALE 1" = 30' KINCAID ROAD arnate '' ~ Alt Sit Absorption Trench LOT 8, BLOCK 4, MUIRWOOD PARK SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home Deep Trench System Perc. Rate: 2 -4 Min./Inch 1,500 Gallon Septic Tank Avg. Application Rate: 1.2 GPD/SF 7' Drain Field Rock 5 Bedrooms X 150 GPD 1 1.2 GPDISF = 625 SF of Absorption Area 625 SFI14 SFILF -- 44.6 LF Trench Length Therefore: Construct an Absorption Trench 45' in Length by 3' Wide With 7' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing Ground. Total Depth of Trench to Be 10' Below Existing Surface. Cover Over Septic Tank a Minimum of 4' or 2" of Insulation and 2' of Cover NOTE: TYPICAL DEEP TRENCH SECTION (NO SCALE) Minimum 6' Separation From Bedrock. Minimum 10' From Lot Line. Minimum 4' Separation From Groundwater. Minimum 100' Separation From Wells in the Area. Minimum t0' Separation From Water Se~ice Line. . : · Municipality of Anchorage Development Services DepartmentJOn-Site Water and Wastewater Program 4700 South Bragaw Street. Anchorage, AK 99516-6650 SOILS LOG - PERCOLATION TEST Performed For: White Raven Development Legal Description: Lot 8. Kincaid Park Subdivision SLOPE 7 8 9 10 11 12 13 14 15 16 17 1S OG/PT SPISM 15% Silt North Date Performed: Was Groundwater Encountered? S If Yes, What Depth?. L Depth to Water After Monitoring None P Date: 5/15102 E SPISM Some GP Bottom of Hole South No SITE PLAN · 50,00' · N90'O0'O0 r't311N~ 1" IRON PIPE Reading Date Gross Net Depth To Net Time Time Water Drop I 22-Jan 3:15 2.75" 3:25 10 5.375" 2.625" 3:26 2.5" 3:36 10 5.125' 2.625" 3:37 2.5" 3:47 10 5.125" 2.625" Perc. Rate: 3.8 Min./Inch Perc. Hole Diameter: 8" Test Run Between 5 Ft. and 6 Ft. Comments: Test Cavity was Presoaked Prior to Test. SW/SM Layer From 7' to 19' Percolates Less Than 5 Minutes Per Inch. Performed By: Alan Harala. I, J~ac~E~3~[~ Certify That This Test Was Performed In Accordance With All State and Municipal Guidelines In Effect On This Datei 8/6/02 Municipality of Anchorage Development Services Department/On-Site Water and Wastewater Program 4700 South Bragaw Street, Anchorage, AK 99516-6650 SOILS LOG - PERCOLATION TEST Performed For: White Raven Development Legal Description: tot 8. Kincaid Park Subdivision SLOPE 8 9 10 11 12 13 14 15 16 18 OG/PTIOL SMISP Was Groundwater Encountered? If Yes, What Depth? Depth to Water After Monitoring Date: North South No None 2/28102 Bottom of Hole ' Date Pcrformed: S L O P E SITE PLAN ; .~ : [--31.42' ... /14G.50' R--20.00 :o, / 50.00 · g"~/ ' N90'O0'O0 FOUND 1" IRON PIPE 0.6' BELOW PAVEMENT Reading Date Gross Net Depth To Net Time Time Water Drop 22-Jan 2:02 4.5" 2:12 10 7.75" 3.5" 2:14 4.5" 2:24 10 7,25" 2.75" 2:25 4.5' 2:35 10 7.19" 2.69" 2:36 4.5" 2:46 10 7.19" 2.69' Perc. Rate: 4 MinJInch Perc. Hole Diameter. 8" Test Run Between 5 Ft. and 6 Ft.... Comments: T([st Cavity was Presoaked Prior to Test. : Pedormed By: ~ I. M~?~L~:II~r~I Certify That This Test Was Per[ormed In Accordance With All State and Municipal Guidelines In Effect On This Date~ .~.: 3/2/02 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 8, BLOCK 4, MUIRWOOD SUBDIVISION GENERAL: The scope of this project includes the procurement an~l placement of a new 1,500-gallon septic tank at the location shown on the site plan and the construction of a 45' long by 3' wide by 7' effective depth absorption trench also shown on the Site Plan. The total depth of the trench will be 10' below existing ground and the distribution pipe will be placed at 3' below the surface. All components of the septic tank and absorption trenches must be constructed a minimum of 10' from the water service line on the lot. A minimum of 4' of fill must be placed atop the septic tank and 3' of fill above the absorption trench. In lieu of fill 2" of direct bury insulation may be placed with 2' of fill atop the insulation. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. The 1,500-gallon septic tank must be procured from an approved septic tank manufacturer and installed at the location shown. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct budal insulation. Lot 8, Block 4, Muirwood September 3, 2002 Page 2 of 2 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: .1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. o e Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. Grade area surrounding the absorption trench to drain away. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall vedfy this condition pdor to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). Lot 8, Block 4, Muirwood September 3, 2002 Page 3 of 3 5. A permeable geotextile fabdc (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the cedifled as-built of the completed system. I.D. 011-422.85 GENERAL INFORMATION Co ,replete legal description Lot 8, Block 4, Muirw0od Park Subdivision I'ocatron (sire'address or directiofis) Parkwest Circle at Kincaid Road Municipality of Anchorage. Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 CERTIFICATE OF HEALTH AUTHORITY APPROVAL FOR A SINGLE FAMILY DWELLING HAA# /~ ~ Expiration Date: I O :'-" ..... (~u~;-e'n~ ~Sr6~erty owner(s) Crown Pointe, Inc. Day phone 727-8167 ·. ' · . v ......-., Mailing address . 5400 Abbott Road Anchora.qe AK 99507. -'.. -'~- ...'.:' ,'~..'~..',' -', ,' l.ending.~ -ac]encv: ·: , , .. '.: '. '..-~.. :. :. '.-.Dav,--ohone ' .-' ......... ':':" ''-' 'MfiiJing:~'dd~-e~'": ':''" ': ' ........ : ' . ' "-' ..'.' Real'E§{at~:Agi~nt - -" ...................... Day phone ................... . ·- Unles~ othe[Wise requested, HAA will be held by DSD forpickup. ' ' 2;:';NUMB'ER I~F BEDROOMS: Five (5) · '~ ""',~:: 'TYPE'OF WATER sUpPLY: -'- TYPE Ola WASTEWATER DISPOSAL: Individual On-site [] ' · .... :,.-~: Individual Well ... :.. :; I-'1 ' '.-',...:' -';', '-'tnd v dual Water Storage ............... ~' [] .................. Individual Holding tank' - ' [] -' x ...... ;i~0,.,m..mu_n!ty.C a.S.S Well [] . Community On-site [] 'P~l~li(~ Wa't~r System [] Public Sewer [] The .... Municipality of Anchorage Development Services Depadment (DSD) Issues Certificates of Health Authority Approval (HAA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. Certificates of Health Authority Approval are required for the transfer of title (except between spouses) for properties served by a single family on-site wastewater disposal and/or water supply system. DSD also issues H. AAs upon request to hc~meowners. Certificates of Health Authority Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water sample, results less than 30 days oId. (Certificates may be reissued for a period of up lo one year with valid water samples.) Cedificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is .not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF'INSPECTION BY ENGINEER As certified by my seal a.ffi~ed hereto and as of the validation date shown below, I verify that my investigation, . based on procedures outlined in the Health Authority Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is(are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further veri~ that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Enqineering · ~ "- ' ' . Address P.O. Box 240773 Anchora.qe, AK 99524 "' Engineer,s Printed Name Michael E. Anderson, P.E. 'L.C. 7. , -;-:: ', - , .';; ": ""5. DSD SIGNATURE Phone 522-7773 Date 411112003 '::L,,, ....... ' Ap ovedfor ?::"?;' - Disapproved. }:;.: L',<L:, .,:, :: ,, ,:. i', ',-:-,.: :COnditional approval for .~,.:..:, ,.:',.,-? .:,' .-'.'.' i, , ... bedrooms, with the following stipulations: Additional Comments .......... Attachments: HAA Checklist Septic System Advisory Well Flow Advisory Ivlaintenance Agreements Supplemental Engineer's Repod Other Original Cedi,qcate, Date: (Rev. 12/00) Municipality of Anchorage .. -. Development Services Department Building Safety Division On-Site Water & Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907) 343-7904 Legal Description: A. WELL DATA Well type .Pubflc Water Date completed Tntal.depth.. fL HEALTH AUTHORITY APPROVAL CHECKLIST Lot 8~ Block 4~ Mubwood Park Subdivision If A, B, or C provide PWSID # Sanitary seal (YIN) FROM WELL LOG g.p.m. Nitrate ~. mg./I. Collected by: Date of test Static water level Well production WATER SAMPLE RESULTS: Coliform colonies J100 mi. Date of sample: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1~500 gal. Foundation cteanout (YIN) Y Date of pumping C. ABSORPTION FIELD DATA Length 46 Total depth 11 fl. Date of adequacy test Number af Compartments _2 Depression over tank (YIN) N_ Pumper New Construction Date installed 9/17/2002 Soil rating (g.p.d./fF or ~/bdrm) t,2 GPDISF ff. Width 3 fl. Eft. absorption area _644 ~ Monitoring tube Y Results (Pass/Fail) Fluid depth in absorption field before test __ in. Water added Elapsed Time: __ min. Final fluid depth in. Any rejuvenation treatment (past. 12 mo,} (YIN & type) N ~ -- Parcel ID: 011-422-85 Well Log (Y/N) Wires properly protected (Y/N) ...... CasingJ~eight (above ground) AT INSPECTION ft, g.p.m. Other bacteria Jrt. Date installed 9/17/2002 Cleanouts (YIN) Y High water alarm (YIN) N System type DeepTrench Gravel below pipe 7 Depres_~ion over field N colonies/100 mi. gal. Absorption rate >= If yes, give date ft. For bedrooms New depth in. g.p.d. D. LIFT STATION Date installed "Pump on" level at in. Datum E. SEPARATION DISTANCES Size in gallons "Pump off" level at __ in. Cycles tesled SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot Absorption field on lot Public sewer main Sewer/septic service line Manhole/Access (Y/N) High waler alarm level at Meets alarm & circuit requirements? On adjacent lots On adjacent lots Public sewer manhole/cleanout Holding tank SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation >5' Property line >5' Water main NIA Water service line >10, Wells on adjacent lots >200' SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Building foundation >10' Surface water >100' Wells on adjacent lots >200' Absorption field >5' Surface water >100' Water main Driveway, parking/vehicle storage Property line >10, Water Service line >10, Curtain drain None Noted F. COMMENTS in. G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA HAA guidelines in effect on this date. Engineer's Printed Name Michael E. Anderson, P.E. Date 4/1'112003 HAA Fee $ 3'7~" Date of Payment Receipt Number (Rev. 12/00) Waiver Fee $ Date of Payment Receipt Number