HomeMy WebLinkAboutTALUS WEST BLK 1 LT 1Municipality of Anchorage Page 1 of 3 Development Services Department On -She Water and Wastewater Program 4700 South Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343.7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number. SW010091 PID Number. 015-201.24 Nar1e Laurence and Caroline Rebischke Wastewater System: New Address: 4921 Talus Drive Anch. AK 99516 ABSORPTION FIELD Ph" 336-4921 Ntanber of Bear°°"" Three 3 Deep Trench LEGAL DESCRIPTION Sal Rating Taal Depth hom original graft .6 GPDFt2 1.5 Ft. Block: Lot Subdesron: Depth to Pipe bottom horn original graft Gravel depth beneath pipe. 1 1 Talus West 4 Ft. 7.5 FL Township: Range: Section: Fill added above original grade. Gravel Length: 1 Ft. 63.6 Ft. Well: New Gravel width: 3 Number of Yves. 1 Distance between lines. Ft. FL Claasnccabon (Pmete, A, B. c): Taal Depth: Cased to: lotal absorption area. lFiVeMatenal Private 175 Ft. 173.9 FL 954 Fe ASTM 3034 PVC Dnben Date Drilled: Static water Level:w. Date Installed. M -W Drillin 519/01 103 FL Digger Dan 516.5/812001 Yield: Ptrnp Set ".cas.g as Above, crotna: TANK 25 GPM Ft. 2 FL SEPARATION DISTANCES ® Septic ❑ Holding ❑ S.T.E.P. ❑ Other: To From Septic Tank Absorption Field Lift Station Holding Tank UMOFFirivate sewer Lrne Anchorage Tank r 11000 Well >100, >100, NIA N/A >25' Steel Two (2) sw,ce wamr >100' >100' NIA N/A LIFT STATION — NONE ON LOT L«Line >5' >10, NIA N/A Gal Fourdetbn >5' >10, NIA N/A �'p on &I. trap vee . Highwater a arin at. F. h. fit curtain Dram None Noted '�° a °°� °°`t °"' °"'°" e° °' Remarks BENCH MARK Location arva vescrom' South Side of Back Door Jam r 100.0 FL Engineers Stamp ..��'wwILaattaft Inspections performed by: MEA Dates: 1" 517101 a. orf %f 49th F r7 UTZ 2nd 511101 • • ' UICHAEL E. ANDERSON f Department of H alth and Human Services approval tj f '•��:` 'cE-.38, No. �jm 1�1F �'•. rF' 0 Reviewed and approved by: Date: zJ o ::�.• ,5 Municipality of Anchorage Page 2 of 3 DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SW010091 PID No. 015-201-24 a3 0 0 o 0 z 1 "=30' 128.06' 10' U.G. POWER & TELE ESbiT. ----- �.s------ M -- �C5 I S S2 TH3 TH4 ®g, Bate r-----------� r------------1 I I I I I I I I ! ee Bedroom I 0 ¢i 0 me I Qo 35' It I � � L $ 1 PLC. DRIVE N 69.59'00"E 108.22' 0 M — TALUS—DRIVE — —� NOTE: Locations Were Not Surveyed or Based On Surveyed As -Built. May Not Be Exact. PLAN AS -BUILT SCALE 1' = 30' LOT 1, BLOCK 1, TALUS WEST SUBDIVISION Wim.. . • �i �'• 49th ' � �� �.M ERS I ' No. CE -4381 = i i cacao xac I t r17A PLC. DRIVE N 69.59'00"E 108.22' 0 M — TALUS—DRIVE — —� NOTE: Locations Were Not Surveyed or Based On Surveyed As -Built. May Not Be Exact. PLAN AS -BUILT SCALE 1' = 30' LOT 1, BLOCK 1, TALUS WEST SUBDIVISION Wim.. . • �i �'• 49th ' � �� �.M ERS I ' No. CE -4381 = i Municipality of Anchorage DEVEOPMENT SERVICES DEPARTMENT 4700 South Bragaw Street Anchorage, AK. 99519.6655 - 343-7904 On -Site Wastewater Disposal System or Well Inspection Report Permit Number: SWO10091 Page 3 of 3 PID No. 015-201-24 PROFILE AS -BUILT Scale: 1" = 10' �1 49th MICHAEL E. ANDERSON No. CE -4381 1 2 3 4 5 6 7 8 9 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, ALASKA 99519-6650 SOILS LOG - PERCOLATION TEST PERFORMED FOR: Laurence Rebischke DATE PERFORMED: 517101 LEGAL DESCRIPTION: Lot 1 Block 1 Rosebud Hills Subdivision ¶ TEST HOLE # 3 SLOPE SITE PLAN MI I � I'� OG/OLPROJECT # M0302 I , I ° 4 a ° Silty Gravel W/Some Sand GM WAS GROUNDWATER ENCOUNTERED? ° IF YES, WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: C DATE: BOH @ 20' 1% None 5115!2001 S L 0 P E SEE SITE PLAN FOR TEST HOLE LOCATION 2% GROSS TIME � o% READING DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP Start 5f7103 9:15 .75" 1 9:45 30 2" 1.25" Recharge 9:46 .88" 2 10:16 1 30 2" 1.13" Recharge 10:17 1" 3 10:47 30 2.07" 1.07" PERC RATE: 28 MIN./INCH PERC. HOLE DIAMETER: 8' TEST RUN BETWEEN 6.5 FT. AND 7.5 T. COMMENTS: Test Hole Pre Soaked Prior to Test. TEST PERFORMED BY: MIKE ANDERSON I, MICHAEL E. ANDERSON , CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 9/20/2003 1 2 3 4 5 6 7 8 9 10 11 12 13 15 16 17 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 SOUTH BRAGAW STREET ANCHORAGE, ALASKA 99519-6650 SOILS LOG - PERCOLATION TEST PERFORMED FOR: Laurence Rebischke DATE PERFORMED: 5/7/01 LEGAL DESCRIPTION: Lot 1, Block 1, Rosebud Hills Subdivision jj��� TEST HOLE # 4 SLOPE SITE PLAN II I I I I I II OG/OLPROJECT # M0302 I I v a Silty Gravel W/Some Sand GM .a e .. a BOH @ 19 WAS GROUNDWATER ENCOUNTERED? IF YES, WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: DATE: i moi;;. s 49th _ 's MICHAEL E. ANDERSON NO. CE -4781 1% NO S L 0 P E SEE SITE PLAN FOR TEST HOLE LOCATION 2% GROSS TIME NET TIME 0°i° READING DATE GROSS TIME NET TIME DEPTH TO WATER NET DROP Start 5/7/03 10:02 1.25" 1 10:32 30 2.13" 1.13" Recharge 10:33 1.13" 2 11:03 30 2.13" 1" Recharge 11:34 1" 3 12:04 30 2" 1" PERC RATE: 30 MIN./INCH PERC. HOLE DIAMETER: B" TEST RUN BETWEEN 4.5 FT, AND 5.5 T. COMMENTS: Test Hole Pre Soaked Prior to Test. TEST PERFORMED BY: MIKE ANDERSON I, MICHAEL E. ANDERSON , CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES ON THIS DATE: 9/20/2003 Job No.: 01-137 Permit No.: SW010091 Project No.: N/A M -W Drilling, Inc. *P.O. Box 110378* Anchorage, AK 99511♦ ♦907-345-4000 • 907-345-3287 Fax* Groundwater Well As -Built & LoQ ♦ Well Owner. Lawrence & Caroline Rebischke ♦ Use of Well: Domestic ♦ Legal Description: Lot 1, Block 1 Talus West Subdivision 4921 Talus West Drive / Anchorage, AK 99516 Construction ♦ Hole Depth: 175' ♦ Casing Size: 6" ♦ Cased To: 173.88' *DrillMethod. Air Rotary ♦Material: A 53 Steel Perf. ♦ Well Completion- Open end X Screen Perforated _ Method. ♦Screen/Perforatlon description: None ♦ Grout /Totes: (1) Sack- No. 8 bentonite granules ♦ Well Development. Method. Air surge Notes: •Static water level (SWL) 103' (above) (below) top of casing (TOC). ♦ Well yield test at 25 gallons per minute (CPM)/geNens per-hour{6Pf1) for with 100% of drawdown (DD) from static level (SWL). *Method. Airlift ♦ Date of completion: 09 May 2001 Well Lot! ♦ Pump Install. hours Depth in feet from top of casing. Details of formations penetrated, size of material color and hardness. 0 TO 2 Casing stickup 2 TO 18 Silty clay: brown 18 TO 30 Silty ravel: brown 30 TO 45 Silty gravel: gray 45 TO 56 Silty gravel: brown 56 TO 59 Sand: dam 59 TO 104 Silty sand: brown 104 TO 124 Sandy gravel: brown 124 TO 156 Silty sand and ravel: dam 156 TO 165 Gravelly sand: dam 165 TO 174 Gravel: water bearing 174 TO 175 Boulder TO TO TO • iI WA—Certified-Contrattor (5m-Wicate No's. 814 & 973 J'A MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 T xis SP€C TivN 7-01 3. Do . M ✓Y� 3,, tri �c 7L, ON-SITE WASTEWATER DISPOSAL SYSTEM 1 WATER SUPPLY PERMIT Initial Date Issued: Apr 27, 2001 Expiration Date: Apr 27, 2002 Permit Number: SWO10091 Parcel ID: 015-201-24 Legal Description: TALUS WEST SUBDIVISION BLOCK 1 LOT 1 , Design Engineer: 0014 Anderson Engineering Owner Name: LAURENCE L. & CAROLINE E. REBISCI Owner Address: 4921 TALUS DRIVE ANCHORAGE, AK 99516 - Site Address: 4921 TALUS DRIVE Lot Size: 17225 SQ. FT. Total Bedrooms: 3 Permit Bedrooms: 3 This permit Is for the construction of: Q✓ Disposal Field Q✓ Septic Tank E] Holding Tank [] Privy All construction must be In accordance with: 1. The attached approved design. Private Well E] Water Storage 2. All requirements specified In Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3, The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. i5. The following special provisions. ` . 'AT THE TIME OF CONSTRUCTION THE ENGINEER SHALL PERFORM ADEQUATE SOILS TESTING IN CONFORMANCE WITH AMC15.65 AND SUBMIT WITH THE INSPECTION REPORT. Received By Issued By Date: Date: 4 — 2 7Qf Municipality of Anchorage • Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907)343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. 01f—?.01 24 Permit Number SWO/009/ Property owner(s) Laurence Rebischke ` CAReti vC E. Day phone 892.6627 Mailing address (1) P.O. Box 520-822 Big Lake, AK sirs fdaiii"g address (2) 4 ?21 TALI($ Vni vg Zip Code Legal description (Lot, Block & Sub'd.) _ Lot 1, Block 1, Talus West Subdivision Legal description (Section, Township & Range) Lot Size / 74 2 Z5- Acres(02 THIS APPLICATION IS FOR: Number of Bedrooms Three (3) Sewer Only ❑ Well Only ❑ Sewer and Well ® Water Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. 77 ;E &a' (Signature of property owner or authorized agent) Permit Fees: Date of Payment: Waiver Fees: Date of Payment: Receipt Number: �J �3 /V Receipt Number: (Rev. 12/00) N4_ ANDERSON ENGINEERING P.O: BOX` 240773 ANCHORAGE, AK 99524 ' 522-7773 5224779 (FAX) .: April 23, 2001 Municipality of Anchorage Development Services Department On -Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 1, Block 1, Talus West Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 1, Block 1, Talus West Subdivision intends to place a new 3 -bedroom home on the lot. We are therefore applying for a permit to construct a new well and septic system on the lot to serve the proposed home. The attached Site Plan and backup documentation identify the location and configuration of the new well and septic system and the parameters used in the design. It also shows the location of the test holes and the alternate septic site. Existing drainage patterns are shown and will not be altered by the development of the lot. Two test holes were placed on the lot in 1994. Soils were found to be silts with some sand. Three percolation tests were run with results from 12 to 18 minutes per inch. The third percolation test was unsuccessful due to frozen ground. Groundwater was not found during the excavation and none was noted during the monitoring period. A recent inspection of the property indicated no water in the monitor tube. We are therefore proposing to place an absorption trench 50' long by 3' wide with 7.5' of effective depth to treat the septic effluent. The pipe will be placed at 3' below the existing ground surface and the total depth of the system will be 10.5'. The Site Plan shows the test holes to be nearly 60' from the new absorption trench. The lot is small in area, however, and we are confident the soils are uniform over the lot. We will perform additional soils and percolation tests during the system construction process and present these results with the as -built for the new system. If the results are found to differ from those utilized in the design the system will be redesigned prior to construction and the City will be notified. The ground surface on the lot slopes as shown on the attached Site Plan with 0 to 1 grades from north to south. For the most part, the lot is flat as shown by the spot elevations shown in the design. The new absorption trench will be constructed parallel to the contours of the surface in conformance with Municipal requirements. Grading will be accomplished to assure surface drainage is away from the new beds. The existing drainage pattern on the lot will not be affected during development. Lot I. Block 1, Talus West Subdivision April 23, 2001 Page Two If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, Vjt,,.� E aV-� Michael E. Anderson, P.E. Attachments •,,Gaoaua OF /a " w. Q�.•........ ••.• . .. � -moo' i' ••.'�T- �" ... .... ....�ry ...�•.�..�.�::.�..�.� MICHAEL E. ANOERSCN CE - 4381 �► H u ssr O o 10000 ,n ; ij�i - •d, 2.1s �� �r,`.y ) T ;' s d k . 'DIY! 75.00 ..a..y> , V,.,rcP>. ' �r�? •3 Mt P,Y N / b ° >� 4 � „*• ) � 0� r p y i I I o 'aiV^ � ► SDO.OT00"E> NOO.O1'00'w — — SDO.045"E_ " 4 F —165.00 I 10•vliu 0'.4. [Sol. a bra w,i ,, I cs- J ou I" t. I I I 0 {w L o.N ; , Vl I F I o 4>... eN e N y L� $00.OT00"E p mr00"w 5 »t 89 44OOa04e35"41 — 6 1]5.15 ,•c — 11S1T — — O'UIB [awl ' y NC, c Ir "M U5.00 sf:, an :v .: U5.14 UO.00 U0. — — — — — I o Y.lti. JS • I• C �,'ih p o Ov �N ­ 0IMP ;0 I f So0•or00T e00.01'D0"w 140.46 U0. , . 135.12 I i89t I I \I moo.. -, I noCIS I • .�?. p:.� - me ;�: N� � I� Le I S00'OT00"E ' n'':n ". •: . O N00• i I N00.0�']S'MI "e �•, 'P:.�`, :':�' 1100.0!'35"w q./' U5.00 .Q .::c:r ':.:p. p .MOO I r � :;»"1 $40.46 ci r pp �1 — — SOD- 0 ' T 3 '�.. — 4 NDO.05'O5'W — I I — — -0 , 25 , 25"..\213.43 ...: -.. ... n 'THIS �E ^.♦ '•; �",. ' r�`<. ; 26341 .. _ 10.1 r ' :.e ••i# �x; V. Y 1 V fOUR'Rodd, .A p K s f f w g ` AREA MAP e����oF E;a:--o SCALE V =100' b W) h0 OVA TALUS WEST SUBDIVISION LOT 1.2BLOCK 1 103' N 89.59'28"E 128.06' Proposed Well N 89059100"E 108.22.' TALUS DRIVE A.C. DRNE SITE PLAN SCALE 1" = 20' II I" 441 26.0' ' 10' U.G. POWER do TELE: ESMT., 50' Long X 3' Wide X 7.5' Eff. Depth Absorption Trench _ _ Alternate _ Site _ _ 1,''000 Gallon o Se tic Tank x x 1 1 ' 1 1 1 1 Three Bedroom ouse 1 1 , 1 1 1 1 OP i zz, ®® da r q h+ U Proposed Well N 89059100"E 108.22.' TALUS DRIVE A.C. DRNE SITE PLAN SCALE 1" = 20' II I" 441 LOT 1, BLOCK 1, TALUS WEST SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Three Bedroom Home Perc. Rate: 18 MinAnch Application Rate: .6 GPD/SF Deep Trench System 1,000 Gallon Septic Tank 7.5' Drain Field Rock 3 Bedrooms X 150 GPD /.6 GPD/SF = 750 SF of Absorption Area 750 SF/15SF/LF = 50 LF Trench Length Therefore: Construct an Absorption Trench 50' in Length by 3' Wide With 7.5' of Drainfield Rock Beneath the Distribution Lateral. Distribution Lateral to Be Placed 3' Below Existing Ground. Total Depth of Trench to Be 10.5' from Existing Surface. Mound Over Trench if Necessary to Provide Minimum Cover of 3'. TYPICAL DEEP TRENCH SECTION (NO SCALE) Q GF.�a�e,eo, NOTE: Grade Area Over Trench to Drain Away. ..���.• � d Minimum 6' Separation From Bedrock •.may/ ///�\\/ \\\ \y/• .^'.. \ //�l\ .•� /\I.. Minimum 100' Separation From Well. �:::::::;•. '................. -Natural . ,.. 216. Backfillex 0 �9 . ,.• W `t �' 4 d 0\wO :• . %Fabric% '' `•; 4" Perforated .'- PVC . (slats *.Down) 716" / Drainfield Rock•' wj • TYPICAL DEEP TRENCH SECTION (NO SCALE) Q GF.�a�e,eo, NOTE: Grade Area Over Trench to Drain Away. ..���.• � d Minimum 6' Separation From Bedrock , �: • Minimum 10' Separation From Lot Line. ,',' 4 O TFI f .� ;• Minimum 4' Separation From Groundwater. • .•.., t�� Minimum 100' Separation From Well. �:::::::;•. '................. MICHAEL E. ANDERSCN : -- 0 Aff 0 ��.•� CE - 4381 . ..� a. • 0 �9 . ,.• W `t �' 4 d 0\wO Municipality of Anchorage DEPARTMENT OF HEALTH S HUMAN SERVICES N ;:.�' '.• 825'1' Street. Anchorage. Alaska 99502-0650 d �,,,;,' ;:..Y• .•-..:..• SOILS LOG — PERCOLATION TEST a 'u,. _• •:• i� •Jau Ent 57mos2'n C'44 PERFORMED FOR: Jim and Denise Cottrell DATE PERF�tME�} LEGAL DESCRIPTION. Lot l—., -.Block 1, Talus '•;%wrhship• Range. Section: TPf 1 DEPT rganic Material SLOPE SITE PLAN Peat_Dk Brn_ Moist V 1 :%✓�oam-Orange, Moist soit Soft 1 2 � — Silt -Grey, Moist, Soft to medium 16 [5.5 ft. Limit of Excavation 17 is 19 WAS GROUND WATER ENCOUNTERED? IF YES. AT WHAT DEPTH? I_W S� L None o P E D" III Weer tiler xNAKiap? None oft 4/19/01 Talus Rd. Lj 20 PERCOLATION RATE None (mmutevmct�) PERC HOLE DIAMETER V TEST RUN BETWEEN 4 FT AND 4' 5 FT COMMENTS TP #1 was soaked with 10 gallons of water on 4-22 and soaked with another 10 gallons of water on 4-23. PERFORMED BY: Stan D0110 f f I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE.- 72-008 ATE72-008 (Rev. 4/85) Owl 101 �� � Lj 20 PERCOLATION RATE None (mmutevmct�) PERC HOLE DIAMETER V TEST RUN BETWEEN 4 FT AND 4' 5 FT COMMENTS TP #1 was soaked with 10 gallons of water on 4-22 and soaked with another 10 gallons of water on 4-23. PERFORMED BY: Stan D0110 f f I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE.- 72-008 ATE72-008 (Rev. 4/85) • I tENG1NE=ctCs�A�L•j��:� jA �.. Municipality of Anchorage I ,y -;= .r• C?�, i ', DEPARTMENT OF HEALTH & HUMAN SERVICES J6, 825'L Street Anchorage. Alaska 99502-0650 r SOILS LOG — PERCOLATION TEST _ •• P: • Jc'ra :Irl S:mF:oo PERFORMED FOR: Lawrence Rebinshke DATE PERFORMED: LEGAL OESCRIPTIONLot 1, _Block 1 Talus W Township. Range. Section; TP A2 DEPTH 2 Organic Material SLOPE SITE PLAN 1 yF"T , 6" Peat-Dk Brn_ Moist V Sof 1, !� Loam-_Orange,LMoist V Soft (I 2 3 4- S - .0' S ' 7 8 ! '/ i 9 /•/% 10 r / •�/ 12 /i i 14 1s' / i Silt w/some sand -Grey, moist, soft to medium is 5.5 ft. Liatit of Excavation 17 18 19 WAS GROUND WATER ENCOUNTERED? IF YES. AT WHAT OEM? j,r S L O P E Ikple b Nam aff None Noone *? om 4 119 / 01 Reading Date Gross Time Net Time Depth to Water Net Drop - -9 1:50 fill I 6" tt sit 2 11:57: 30 1 :1 mi 4" III " f'1 ,v 1 1251' 2.875" 1 f'1 6" 4 10 12-57-30 0 0 min 1 3.5" 2.5' it12-57-10 " I 3:27:30 b0min 1 3.5" 1 2.5" 20 -t, I 6 tt UPERCOLATION RATE 12. lmmutesrmr�I POC HOLE DIAMETER TEST RUN BETWEEN 4 FT AND 4 • 5 FT COMMENTS TP #2 was soaked with 10 gallons of water on 4-22 and soaked with anorh r TO gallons of water on 4-23. PE4FORMEOl3Y: Stan Rolloff 1 CERTIFY? HAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALLSTATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS OATS. DATE: :-008 IRew. 4,851 Dur [toad ^.:< tJI He R`,r �r.;,i (ENGINEER'S SEAtj 40 Municipality of Anchorage "' "•��.•.." DEPARTMENT OF HEALTH 8 HUMAN SERVICES ......... .....,.. 82S -L" Street, Anchorage, Alaska 99502-0650� ;`: 2aa.rr C. i!r•I, .' SOILS LOG --PERCOLATION TEST c� :E FJ3• r��'% PERFORMEDFOR: Laurence Rabischke DATE PERFORMEO- M�y 10, 1994 LEGAL DESCRIPTION: Lot 1 Block 1 Tal os West Township, Range, Section. SLOPE SITE PLAN (FEET) 1 2 3 _ \1 �,rp��'• OF •q gs'll atl a. Gj 414'•',9 01 , 5 r�:tt�iN,► 'fir •....•• ...� 6 •% y� / 7 F�1I err :••• =E sda. FBF 4•.• ..•' F�.� 8 ; \t. 190FESS10� 9 tOt 12 1� John Earl Simp ��- 13 pie l•, cE-io61 �•v�:F, 15 16 17 18 19 WAS GROUND WATER ENCOUNTERED? S IF YES, AT WHAT L O DEPTH? P E Depth to Wala After Man.toring7 031t Reading Date Gross Time Net Time Depth to Water Net Drop 5/10/94 130745 Fill 41" 1 5/1079-4 13 min. 1340:30 Refill 41" 2 .5/10/94 15/10/94 1410:30 30 min. 42 11/16-' 1 11/16111 S 10 94 1412:50 Refill 41" 3 5/10/94 1442:50 30 min. 42 11/16111 11/161+ 20 DERCOLATION RATE /7 -?S tmrnutevrntnl PERC HOLE OtAMETER 6rI IESI RUN BETWEEN 7 FI ANO 7.5 FT COMMENIS Client Wanted a percolation test only another engineer_ performed test hole analvsi! PERFORMED BY Kent Sheets CEH'INIHAI hl!>IESI WAS PEIIrORMEOIN ACCORDANCE WIIH ALL SIAIE AND MUNICIPAL GUIDELINES IN EFFECT ON IRISDAIE DAIS 12 LOW IHev 4,85) . ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 1, BLOCK 1, TALUS WEST SUBDIVISION GENERAL: 1. The scope of this project includes the procurement and placement of a new 1,000 gallon septic tank at the location shown on the site plan. Work also includes the construction of a new 50' long X 3' wide X 7.5' effective depth absorption trench at the location shown. The distribution line in the trench will be placed at 3' below the existing ground surface. • Total depth of the trench will be 10.5' below the existing ground surface. All components of the septic system must be placed a minimum of 100' from the well on this and adjacent lots. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The.Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Department of Health and Human Services for system installations. Owners installing their own systems must receive prior approval from D.H.H.S. before beginning system installation. SEPTIC TANK INSTALLATION 1. A new 1,000 gallon septic tank must be be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. Lot 1, Block I. Talus West Subdivision April 23, 2001 Page 2 of 3 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. Grade area surrounding the absorption trenches to drain away. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. Contractor shall verify this condition prior to placement of the rock. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Femco, or equal). Lot I. Block 1, Talus West Subdivision April 23, 2001 Page 3 of 3 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as -built of the completed system. Municipality of Anchorage On -Site Water & Wastewater Program (907) 343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL Parcell.D. 015-201-24 Expiration Date: 1. GENERAL INFORMATION Complete legal description TALUS WEST: BLOCK 1, LOT 1 Location (site address) Current Property owner(s) Mailing address Real Estate Agent 4921 TALUS DRIVE *ANCHORAGE, AK 99516 REBISCHKE TRUST Day phone C/O AGENT 4921 TALUS DRIVE *ANCHORAGE, AK 99516 JIM STANDIFORD W/ DYNAMIC Day phone 2. TYPE OF DWELLING: y Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 244-3940 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual On-site 0 Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System ❑ Public Sewer ❑ Received by: COSA to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ 9'!3o— Date of Payment q ii`�I (01 C__in� � Receipt Number 6214gG COSA # ©SC (a 1't Y) Date: Waiver Fee $ Date of Payment Receipt Number. Waiver # S. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone Address 3701 E. TUDOR ROAD, SUITE 101 * ANCHORAGE, AK 99507 Engineer's Printed Name JEFFREY A. GARNESS, P.E. Engineer's Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines & Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever 6. DSD SIGNATURE System #1 Approved for bedrooms. System #2 Approved for bedrooms. Disapproved. 337-6179 Date 4 OF.. G•• of ness,- oOQ 9 CEE-795 m`pp tOF (Af r,� ON-SITE -- � WATER AND -o WASTEWATER �^ PROGRAM Conditional approval for bedrooms, with the following stipulations: The Municipality or Anchorage Develop,emt Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the represenatations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTCHMENTS: COSA Checklist r / Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Other By: / Original Certificate Date: Y 124 rl (Rev. 11105) If more than 1 septic system is on the lot: COSA Checklist # _of_ Structure served by this system Certificate of On -Site Systems Approval Checklist Legal Description: TALUS WEST: BLOCK 1, LOT 1 Parcel ID: 015-201-24 A. WELL DATA Well type PRIVATE If A, B, or C provide PWSID# N/A Well Log (Y/N) YES Date completed 5/9/01 Sanitary seal (Y/N) YES Wires properly protected (Y/N) YES Total depth 175 ft. Cased to 173.9 ft. Casing height (above ground) 18+ in. FROM WELL LOG AT INSPECTION Date of test 5/g/01 9/18/12 Static water level 103 ft. 107 ft, Well production 25 g,p.m, 7.27 g.p.m. WATER SAMPLE RESULTS: Coliform 0 colonies/100 ml. Nitrate 1.05 mg./L. Collected by: GEG. Ltd. Arsenic: ND ug./L. Date of sample: 9/6/12 B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 5/7/01 Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) YES Foundation cleanout (YIN) YES Depression over tank (Y/N)+'NO High water alarm (Y/N) N/A � Date of pumping 1/'-)- l a. Pumper A4 N_orm c SC, -U j C G S C. ABSORPTION FIELD DATA BELOW EXISTING GRADE Date installed 5/7/01 Soil rating (g.p.d./ftbr /bdrm 0_6 System type TRENCH Length 63.6 ft. Width 3 ft. Gravel below pipe 7.5 ft. Total depth *13.62 ft. Eff. absorption area 954 ft2 Monitoring tube YES Depression over field NO Date of adequacy test 9/18/12 Results (Pass/Fail) PASS For 3 bedrooms Fluid depth in absorption field before test 33 in. Water added 720 gal. New depth 51 in. Elapsed Time: 120 min. Final fluid depth 42 in. Absorption rate >= 450+ g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) NONE If yes, give date D. LIFT STATION Date installed Size in gallons "Pump on" level at in. "Pump off" E. SEPARATION DISTANCES Manhole/Access water alarm level at Cycles tested Meets alarm & circuit requirements? SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tankAift station on lot 100'+ On adjacent lots 100'+ Absorption field on lot 100'+ On adjacent lots 100'+ Public sewer main Sewer /septic service line 25'+ Public sewer manholetcleanout N/A Holding tank Animal containment areas 50'+ Manurelanimal excrete storage areas 100'+ SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main N/A Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Properly line 10'+ Building foundation 10'+ Water main N/A Water service line 10'+ Surface water 100'+ Driveway, parkingIvehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I ceriify that t have determined through freld inspections and review of Municipal records that the above systems are in conformance with MOA COSH guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date %/ z-gbz (Rev. 11105) � � 9/Q& Hno s =.m.e m e < --- 0 � /� \:� !\ \ \ \ \ z �Ul