ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT
Permit Number: SWO20123 PID Number: O50-981-O7
Name: Wastewater System: New
Jerome Monta~ue
· Address:
1835 Mount Yukla Circle Ea~lle.'River, AK ABSORPTION FIELD
Phone: Number of Bedrooms: 5' Wide Trench
622-2525 Four (4)
Soil" Rating: Total Depth from original grade:
LEGAL DESCRIPTION 1.2 GPD/Ft= 9.0 Pt.
Block: Lot: Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe:
SE4NW4NWfSW4 4.5 Ft. 4 Ft.
Township: Range: Section: Fill added above odginal grade: Gravel Length:
13N ,1E 10 OFt. 52 Ft.
Gravel width; Number of lines: Distance between lines:
Well: New 5 Ft. 1
Classification (Private, A, B, C): Total Depth: Cased to: Tota absorption area Pipe Material:
Private 181 Ft. 181 Ft. 520 Ft2 ASTM 03034 PVC
Driller:. Date Drilled: Static Water Level: Installer. Date Installed:
Sullivan Water Wells, 6/19/02 I05 Ft. Jones Excavatin,~ 7/1-7/6/2002
Yield:lo GPM { Pump Set at:Ft. I Casing Height >2Ab°VeFt.Gr°und:TANK
SEPARATION DISTANCES [] septic [] Holding E] S.T.E.P. [] Other:
To Septic Absorption Lift Holding =ublic/Private Manufacturer: Capacity in Gallons:
Tank Field Station Tank Sewer Line ,A, nchorag<~ Tank 1,2.50
Material: Number of Compartments:
We, >100' >100' N/A N/A~ ;>25' Steel Two (2)
Surface Water >1OO' >1OO' N/A N/A ~ / LIFT STATION - NONE' ON LOT
Size: Manufacturer:
Lot Line >5' >10' N/A N/A Ga~.
' "Pump on" level at: ' ' "P,',mp offf level
Foundation >5m >10' N/A N/A ~n, in.I in.
Curtain DrainNolle Noted Pump Make'& Model Electrical Inspections performed by:
Remarks:
2" Insulation Over Line Under Driveway. BENCH MARK
Lecafion and Description:
,, Oaraoje Floor.
Assumed Elevation:
1OO.O Ft.
Engineer's Stamp
Inspections performed by: ME_25 Dates: 1~ 7/1/0.2
Department of I-{lealth and Human Services approval
Reviewed and approved by:. . , , _.
Municipality of Anchorage Page 2 of 3
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bmgaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW020123 PID No. 050-981-07
r~
O
Z
N 89'58'28"E 2,34.79'
EXISTING PRIVATE
-- ACCESS DRIVE
s1 '9.$ 23.7
$2 17.2 26.2
Mi 71.5 88,7
c4 68.0
c5 ¢7.5 151.3
PRIVATE RIGHT
WAY ESMT, '
[20' BZ 1~54, PO 338)
(iS' BK 195¢. PG 543)
N 89'58'42"E
DRIVE
)ur Bedroom
Home
N 89'58'55"E 100.00'
WELL
80,3'
Municipality of Anchorage
DEVEOPMENT SERVICES DEPARTMENT
4700 South Bragaw Street Anchorage, AK. 99519-6655 - 343-7904
On-Site Wastewater Disposal System or Well Inspection Report
Permit Number: SW020123
Page 3 of 3
PID No. 050-981-07
~--99.6
~ /i'Ll It,Il")
850 Gal, ton To
~5.~~ I I ~94.95
82,0 -/
87.0
Geo t:ex'l;i[e F(~bric
DrninFietd Rock
52'
~ 88.t
??.5
69.5
PROFILE AS-BUILT
Scole: 1" = 10'
(gertiQeb ri[l:ing .og
DOC CO, dba
SULLIVAN WATER WELLS
P.O. BOX 670272, CHUGIAK, ALASKA 99567 · TELEPHONE 688-2750
OWNER OF LAND: [ ~+'"~q~ , /¢'¢¢"~ ~ ~.~,~ BORE HOLE DATA
DEPTH
From To
? : 'f: ~"'r,¢
ADDRESS:
Method of DnH~n~:~ota~ ,a cable tool
Depth of well: /,~,, [
Casing Type .}~"7e *~ Wall Thickness ~ :_-:'~ ~ inches
Diameter (¢:; inches, depth / ~ feet
~" Casing StickuP Above Ground:~ <~ feet
Static Water Level: ~ O ~ feet
R~over Rate: ~'~ gpm
Method ofTesting: , ~
Well Intake Opening Type: ~n end Q open hole
Q Scr~ned; Start feet Stopped feet
G
ro
u
t
ype:
Depth: from (~ feet, to -. ~)~ feet
Well Disinf~t~ Upon Completion? ~s Q No
Comments:
~ .... Driller's Name
ATTENTION: It is the responsibility of the property owner to submit a copy of the well Icg to the proper authority, Municipality
of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. MatSu Borough:
Department of Environmental Conservation.
MUNICIPALITY OF ANCHORAGE
Development Services Department
On-Site Water & Wastewater Program
4700 South Bragaw Street
P.O. Box 196650, Anchorage, AK 99519-6650
(907) 343-7904
ON-SITE WASTEWATER DISPOSAL SYSTEM /WATER SUPPLY PERMIT
Initial
Date Issued: May 21,2002
Expiration Date: May 21, 2003
Permit Number: SW020123 Parcel ID: 050-981-07
Legal Description: T13N R1E SEC 10 SE4NW4NW4SW4 LESS PTN
Design Engineer: 0014 Anderson Engineering
Owner Name: Jerome Montague
Owner Address: 1835 Mount Yukla Cir.
Eagle River, AK 99577~
Site Address:
Lot Size: 92347 SQ. FT.
Total Bedrooms: 4 Permit Bedrooms: 4
This permit is for the construction of:
~ Disposal Field [] Septic Tank
[] Holding Tank [] Privy
[] Private Well
Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ).
3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling
(907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
must be either: A. Open and closed on the same day.
B. Covered, sealed, and heated to prevent freezing.
Issued By: ~
Date: .~'- /Z / /~ Z
Municipality of Anchorage
Development Services Department
Building Safety Division
On-Site Water and Wastewater Program
4700 South Bragaw St.
P.O. Box 196650 Anchorage, AK 99519-6650
www.ci.anchorage.ak, us
(907) 343-7904
ON-SITE SEWER/VVELL PERMIT APPLICATION
FOR A SINGLE FAMILY DWELLING
Parcel I.D. ¢-_)~%--~r-)..- 9 ~ I - ~)"'7
Permit Number SWO?- 0/Z 3
Property owner(s) Jerome Montague Day phone 622-2525
Mailing address (1) 1835 Mount Yukla Circle Eagle River, AK 99577
Mailing address (2) Zip Code
Legal description (Lot, Block & Sub'd.)
Legal description (Section, Township & Range) SE;Il4 of NWll4 of NWll4 of SW114 Excepting the Easterly 100'
of the N112 of SE 1/4 of NW 114 of NW IA of SWI/4 of Section '10, T13N, R1 E, S.M.
THIS APPLICATION IS FOR:
Sewer Only []
Sewer and Well []
Sewer Upgrade []
THIS PROPERTY CONTAINS:
Hot Tub
Swimming Pool []
Therapy Pool [--I
Number of Bedrooms Four (4)
Well Only []
Water Storage []
Jacuzzi []
Water Softening Unit []
I certify that the above information is correct. I further certify that this application is being made for a
Single Family Dwelling and is in accordance with applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit Fees:
Date of Payment:
Receipt Number:
Waiver Fees:
Date of Payment:
Receipt Number:
I" .':' '.". ANDERSON'ENGINEERING:... :"" I
.' :..::': ' P.O,'BOX240773' '.: ,':' · I
' :.=" .' ANCHORAGE, AK'99'524' '.. '[
:: 522-7773 ·. 522.6779 (FAX) ..''. '" '!
May 15, 2002
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject:
SEl/4 of NWl/4 of NW ¼ of SW ¼ Excepting Therefrom the Easterly 100'
of the Nl/2 of SE ¼ of NW ¼ of NW ¼ of SW ¼ of Section 10, T13N, RIE
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the subject property intends to construct a four-bedroom home on the lot.
We are therefore requesting a permit be issued for the construction of a new well and
septic system to serve the home. The attached Site Plan and backup documentation
identify the location and configuration of the new well and septic system and the
parameters used in the design. Also identified on the plans are the location of the well
on the lot, test hole locations and the locations of existing wells and septic systems in
the area. No conflicts will exist between the new septic system and the well on this or
adjacent lots. Existing drainage patterns are shown and will not be altered by the
development of the lot.
The test holes placed near the location of the proposed absorption trench and alternate
site indicate fairly clean silty gravel at a depth approximating 5'. The percolation test
completed in the material reSulted in rates of 2 to 3 minutes per inch. No groundwater
was found dudng the placement of the test holes and none was noted during the
monitoring period. We are therefore proposing to place a 5' wide by 50' long by 4'
effective depth absorption trench on the property. The total depth of the trench will be
9'. The distribution pipe will be placed at 5' below the ground surface to allow gravity
flow from the septic tank and take advantage of the gravel material.
The ground surface on the lot slopes as shown on the attached Site Plan with moderate
to steep slopes from southeast to northwest. The new absorption trench will be
constructed in conformance with Municipal requirements and parallel to ground
contours where possible. All components of the new septic system will be constructed
a minimum of 100' from the well on the lot and 10' from the service line from the well to
the house.
If the system is constructed in accordance with our design the following statements
apply:
'Portion of T13N, RIE, Section 10
May 15, 2002
Page Two
The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
Sincerely,
Michael E. Anderson, P.E.
Attachments
LEGAL DESCRIPTION
N
AREA SYSTEM PLAN
SCALE 1" = 100'
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 522-6779 (FAX)
MEMORANDUM
DATE:
June 15,2002
TO:
Dan Roth
FROM:
Mike Anderson, P.E.
SUBJECT:
SEll4, NWl14,NWI14, SWll4 Except Easterly 100'
Well and Septic System Permit No. SW020123
Modified Well Location
We have modified the location of the well proposed for this lot to allow easier access for
the well driller. The attached drawing shows the new location. This location will not
conflict with the septic system proposed for this lot or those on adjacent lots. Please
modify the permit to allow placement of the proposed well at the modified location.
N 89°58'28"E 234,79'
o.
Z
N 89°58'35"E
100.00'
50' LiD
ABSORP
PRWATE RIGHT WAY ESMT.
(20' BE 1954., PI3 538) '
(15' BK 195,L P~
N 89°58'4.2"E 335.22'
SITE PLAN
SCALE 1" = 50'
TREE
108'
EXIS'rlNG PRIVATE
DRIVE
\
0
g
0
50' LO
EFFI~
PRIVATE RIGHT
WAY ESldT.
(20' eK ~9~4, Po .x~e)
(15' BK 1g§4, PG 345)
N 8g"58'28"E
234,7g'
)EPTH
4'
TH1
SEPTIC TANK
N 89°58'42'E
TH2
g
Z
N 8g*58'35"E 100.00'
O
TREE
X IOB'
PROPOSED
WELL
B1,5'
0
Z
SITE PLAN
SCALE 1" = 50'
MICHAEL E, ANDERSON
NO. CE-45B1
T13N, R1E, Section 10
SE4, NW4, NW4, SW4
DESIGN FACTORS:
SYSTEM REQUIREMENTS:
Four Bedroom Home
Perc. Rate: 2.7 Min./Inch
Application Rate: 1.2 GPDISF
5' Wide Trench System
1,250 Gallon Septic Tank
4' Drainfield Rock
4 Bedrooms X 150 GPD 11.2 GPD/SF = 500 SF of Absorption Area
500 SFI5 LF (Width)*.5 (Red. Factor) = 50 LF Trench Length
Therefore: Construct a 50' Long X 5' Wide X 4' Effective Depth Absorption Trench.
Flowline Elevation in Trench to be 5' Below Original Ground Surface. Total Depth to be 9'
Below Existing Ground. Mound Over Trench to Provide a Minimum of 3' of Cover or
Provide 2" of Direct Bury Insulation and 2' of Cover.
4.5':'.
NATURAL BACKFILL
(3' MINIMUM)
GEOTEXTILE FABRIC
4" PERFORATED PVC
(SCHEDULE 40)
DRAINFIELD ROCK
NOTE:
TYPICAL WIDE TRENCH SECTION
(NO SCALE)
Grade Area Over Trench to Drain Away.
Minimum 6' Separation From Bedrock.
Minimum 4' Separation From Groundwater.
Minimum 100' From Wells in the Area. ·
Minimum 10' Separation From Water Service Line.
Municipality of Anchorage
Development Services Department/On-Site Water & Wastewater Program
4700 South Bragaw Street Anchorage, AK 99519
SOILS LOG ~ PERCOLATION TEST
Performed For: Jerome Montague
Legal Description: T13N. RIE. S10. SE4, NW4, NW4, $W4
SLOPE
Date Performed:
SITE PLAN
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
18
22
OGIPT
TEST HOLE..NO. 2
OL/ML
GM
Dark Brown
Cobbles
Trace
to 24"
Was Groundwater O~!
Encountered? No S
If Yes, What Depth? L
Depth to Water
After Monitoring None
Date: 5115/02
Bottom of
Hole
See Site Plan
Reading Date IGross INet Depth To Net
vr:~ ~Timu Water .
I 27-Apr 4:26 10.38"
2 4:36 10 15.31" 4.94"
3 4:37 10.31"
4 4:47 ~10 13.94" 3.63"
5 4:48 10.5"
6 4:58 10 14.13" 3.63"
Perc. Rate: 2.75 Min./Inch Perc. Hole Diameter:
Test Run Between 5 Ft. and 6 Ft.
Comments: Test Hole Pre Soaked Prior to Testing.
Performed By: Mike Anderson, I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 5115102
Municipality of Anchorage
Development Services Department/On-Site Water & Wastewater Program
4700 South Bragaw Street Anchorage, AK 99519
SOILS LOG - PERCOLATION TEST
Performed For: Jerome Montague
Legal Description: T13N. RIE, $10, $E4. NW4, NW4, $W4 ..
SLOPE
Date Performed:
SITE PLAN
4~7~2
1
2
3
4
5
6
7
8
9
10!
12
13
~4
'15
18
22
OGIPT
TEST HOLE NO. 1
OL/ML
GM
See Site Plan
Dark Brown
Cobbles
Bottom of
Hole
Was Groundwater O EPI
Encountered? No S
If Yes, What Depth? L
Depth to Water
After Monitoring None
Date: 5115102
Reading Date IGrc iNet Depth To Net
...... 'jTime IWater ~.,'op
1 27-Apr 2:18 11.63"
2 2:28 10 16.07" 4.44"
3 2:29 11.75"
4 2:39 10 15.5" 3.75"
5 2:40 11.5"
6 2:50 10 15.38" 3.82"
Perc. Rate: 2.7 Min./Inch Peru. Hole Diameter:
Test Run Between 5 Ft. and 6 Ft.
8#
Comments: Soils Encountered are Similar to Those in Testholes 21 and 22.
Test Hole Pre Soaked Prior to Testing.
Performed By: Mike Anderson. I, Michael E. Anderson Certify That This Test Was Performed
In Accordance With All State and Municipal Guidelines In Effect On This Date: 5115102
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: Portion Of T13N, RIE, Section 10
GENERAL:
The scope of this project includes the procurement and placement of a
new 1,250 gallon septic tank at the location shown on the Site Plan.
The new septic system also includes the construction of a new 50'
long X 5' wide X 4' effective depth absorption trench at the location
also shown on the Site Plan and at the configuration shown. The
distribution line in the trench will be placed at 5' below the existing
ground surface. Total depth of the trench will be 9' below the existing
ground surface. The new absorption trench and septic tank must be
placed a minimum of 100' from the well on the lot and 10' from the
water service line between the well and the house.
Construction shall be in accordance with the approved site plan,
design drawings, Municipal Permit with anY special provisions or
conditions, and all applicable State and Municipal Wastewater
Disposal Regulations.
The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the
location of all lot lines.
Unless specifically agreed otherwise, the contractor shall be
responsible for final grading areas subsequently depressed from soil
settling. Property owner shall be responsible for revegetation of
affected areas unless specifically agreed otherwise.
Contractors installing wastewater disposal systems must be certified
by the Municipal Department of Health and Human Services for
system installations. Owners installing their own systems must receive
prior approval from D.H.H.S. before beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250-gallon septic tank must be procured from an approved
source and installed at the location shown.
A septic tank is to be constructed by a certified septic tank
manufacturer. Construction shall include two 4" cleanouts for pumping
access.
3. The septic tank shall be sufficiently bedded to prevent settling or
shifting of the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches
above final grade.
5. Tanks installed without 4' of cover shaii have a minimum of 2'~ of direct
burial insulation.
Portion of T13N, R1E, Section 10
May 15, 2002
Page 2 of 3
A foundation cleanout shall be installed one to four feet from the
building foundation. Two cleanouts are required between the tank and
the drainfield.
7. Final grading over the tank shall be such that a positive slope exists
away from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the
design. The bottom of the trench shall be within 2" of level.
Distribution piping must be placed level with perforations down atop a
level bed of drainfield rock. Rock should then be placed over the pipe
to provide a minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield
rock and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations
shown on the design. The portion below ground must be perforated.
Contractor shall verify the septic tank and drainfield are a minimum
100' away from any private water wells in the area, 150' from a Class
"C" Well or 200' from any community well.
Direct bury insulation must be placed over the distribution system if
less than 3' of backfill depth is available. Finish grade over the trench
must be mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
A minimum 2' of accepting soil is required below the drainfield rock for
a 5' wide trench. Contractor shall verify this condition prior to
placement of the rock. All pockets of unacceptable materials must be
removed and replaced.
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic
tank manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated
and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and
ASTM D2662 or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene
(Dow Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
Portion of T13N, RIE, Section 10
May 15, 2002
Page 3 of 3
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing
the #200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These
inspections must be conducted under the supervision of a professional
engineer registered in the State of Alaska. The first inspection must be
conducted after the excavation of trenches, beds or pits and before the
installation of any gravel. A septic tank may be set in place, but may not
be backfilled.
The second inspection must be conducted after the placement of the
geotextile fabdc, gravel, distribution piping, standpipes, cleanouts and
insulation. No backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction
notes for use in preparing the certified as-built of the completed system.