Loading...
HomeMy WebLinkAboutROCKHILL BLK 2 LT 8AI ockhill lock Lot 8 5- 362 MUNICIPALITY OF ANCHORAGE On -Site Water & Wastewater Program S.. PO Box 196650 4700 Elmore Road�- Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http://www.muni.org/onsite i 111 Depa tme�tt On -Site Wastewater Disposal System Permit Permit Number: OSP201195 Effective Date: 6/26/2020 Work Type: SepticTank Upgrade Tax Code Number: 01536235000 Site Legal Address: ROCKHILL BLK 2 LT 8A G:2438 Site Mailing Address: 6450 SHALE CIR, Anchorage Owner: SWAN JOHN H Design Engineer: ANDERSON CONSTRUCTION & ENGINEERING This permit is for the construction of: ❑ Disposal Field Q Septic Tank ❑ Holding Tank ❑ Privy Expiration Date: 6/26/2021 Lot Size in Sq Ft: 51656 Total Bedrooms: G ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: Date: Issued By: / g Lt/ Date: MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 ON-SITE SEPTICM/ELL PERMIT APPLICATION Parcel I.D. 015-362-35 Property owner(s) HANK SWAN Day phone Mailinq address 6450 SHALE CIR, ANCH AK Site address SAME Legal description (Sub'd., Block & Lot) ROCKHILL BLK 2 LT 8A Legal description (Township, Range & Section) Lot Size 51,656 Sq. Ft. Number of Bedrooms 5 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑ Initial ❑ Single Family (SF) El (w/wo ADU) Septic Tank 0 Upgrade 0 Duplex ❑ (D) Holding Tank F-1Renewal F-1Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: Date of Payment: Receipt Number: Permit No. 05 P 2.0 I Cts Waiver Fees: Date of Payment: Receipt Number: Waiver No. GADevelopment Services\Building Safety\On Site Water and Wastewater\Forms\Client Forms\Permit Application.doc June 25, 2020 Municipalities of Anchorage Departments of Health and Human Services P.O. Box 196650 Anchorage, Alaska 99519-6650 Fax 249-7847 Re: New septic tank permit Legal: ROCKHILL BLK 2 LT 8A To Whom it may concern: This is a request for a septic tank permit on the above referenced lot. This tank replacement will not impact any of the neighbors or encroach on any wells, septic or open water issues. Sincerely Michael N. Anderson, P.E. 4661 Natrona Anch, Ak 99516 Ph 727-8864 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201195, Deb Wockenfuss, 06/26/20 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP201195, Deb Wockenfuss, 06/26/20 Permit Number: ~'-A'N V.. Number of Bedrooms' '7'70- 'l q,t3~ ..6 LEGAL DESCRIPTION Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program, 4700 S. Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.cLanchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT PID Number: Wastewater System: [~qew [] Upgrade L. oT' ~; BY-, E-: EocV..14t~L ¢' lc) T c..v- s~'.,C Range C~New [] Upgrade J Slaho Waler Level; ~LPi~I~~ I Pum~ Set aL SEPARATION DISTANCES Well: C:as$ r~ca!,c~ (~rwate. A e. C) D',;ler Seotic Tank Absorption Field LO, L,,e I C::) J 0 jo I0 Lift Station Holding Tank Public/Private Sewer Line Page I of..~ ABSORPTION FIELD KOeep Trench ID Shatlow Trench ID Bed n Mouncl ID Cite' Soil Rating' Deplh Io p,oe bollom from ong~nal grade Fill added above oOginal grade* ,M~ Ft. Gravel width Total ab$orpbon area: 1080 ~,' Installer:. 'Ti~^I L Total Depth from crtgmal g,ace Gravel depth beneath Graver Leng,'h. Number of bnes Pipe Matenal Da:e In$1atled - TANK ~3eptic r-I Holding [] S.T.E.P. [] Other: Manufacturer. Material: LIFT STATION JElect,'ic~l Inspechons performed by' *Pump On' level at Pump Make & Model BENCH MARK .OCatlOfl arx:[ DesC~pho~ NE "-¢.,-o Al_ ~ (la..c/v/' Inspections performed by: 1...~ Dates: 1st Development ~e~rvices Department Approval Reviewed and approved by: ire-, IZnql ~L'IVCH I&4RK AS~ £LEVATION 100.00 fT. $-BL~ SL'PTIC 1500 GALLON S~PTIC TANK 60FTOf'TRL'NCH 14 r~L'l' DEEP ~5' 0 ~ 75 =50 : 49%h C£-eRR5 CORNER L'LL'VATI~ I00.00 FT TOBBEN SPURKLAND P.E. 205 Pt 15TN. AVENUE ANCI'/. AK. 99501 (90Z) B£OCK£NANK sPiANROCKItlI'I' $500 SHALE CIR¢I.E SEPTIC SYSTEM AS BUILT DATE: SEPT. 12, 2003 SHEET: 2/3 GRID: 2438 PERMIT tt $V030030 PID ii 015-362-25 RUHO2fl$2.DVG 1500 ~o! Septic t~nk St~nd~rd frencht £' Vide 60' Lon9 14' Beep 9.0' Sewer rock 5' Cover NO SCALE Monitor ~-- Clesnouts 9.0 £t o£ Septic Rod< / NO SCALE 1500 got septic tonk t~I~H ~tARN: N£ PRP. CORNER ASSUH£D £lt'VAIION I00.00 ~T TDBBEN SPURKLAND P.E. Il 203 ~/15~ch Ave Anchorage Ak 99501 ~,79--~916 LO? 8 BLOCK £ ROCI~tlII~ HANK SWAN i j SEPTIC SYSTEM SCHEMATIC DATE, SEPT. 12, 2005 SHEETm $/$ GRID, c°438 PERJlIT ~ STY030030 PARCEL /0 t~ 015-362-25 ROHO2OS$.DWG Municipality of Anchorage Department of Health and Human Services 825 "L" Street P.O. Box 196650 Anchorage, Alaska 99519-6650 Rick Mystrom http://www.ci.anchorage.ak.us Mayor - . MAR Permit Number: #SW 030030 Date of Issue: 3-3-03 Parcel Identification Number: 015-362-25 Date Started: 3-12-03 Date Completed: 3-13-03 Is xvell located at approved permit location? [] Yes [] No Legal Description: Rockhill Block 2 Lot 8 Properly Owner Name & Address: Hank Swan 115 E 80/h Ave. Anchora~le, Alaska 99518 Borehole Data: Depth (ft) Soil Type, Thickness & Water Strata From To stick-up 0 2 -8i'ganics & silt 2 4 gravelly silt 4 15 gravel 15 31 silty gra vel 31 55 gravelly silt 55 63 sandy silty gravel & water 63 68 gravelly silt 68 81 Method of Drilling [] air rotary [] cable tool Casing type: ,steel Wall Thickness: .250 inches Diameter: _6 inches Depth: 8/feet Liner Type: ~ Diameter: ~ inches Depth: ~ Casing stickup above ground: _2 feet feet Static water level (from ground level): 28.feet Pumping level: 65 feet after _2 hours pumping _7 gpm · Recovery Rate: _7 gpm Method of Testing: air lift Well Intake Opening Type: [] Open End [] Open Hole ' [] Screened Start ~ feet Stopped ~ feet [] Perforations Start-6~4 feet Stopped 68 feet Grout Type: Bentonite #8 Volume: 1 bg Depth: Start 0 feet Stopped ? feet Pump: Intake Depth ~ feet Pump size ' ' hp Brand Name Well Disinfected Upon Completion? 15~ Yes I--] No Method of Disinfection: chlorine tablets Comments: Wall Driller: Alpine Drilling & Enterprises PO Box 110496 Anchorage Alaska gg511 Attention: The well driller shall provide a well log to the property owner xvithin 30 days of completion and the property MUNICIPALITY OF ANCHORAGE Development Services Department On-Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM I WATER SUPPLY PERMIT Initial Date Issued: Mar 03, 2003 Expiration Date: Mar 02, 2004 Permit Number: SW030030 Legal Description:£R~&khill BI6~:k'2 I~t-~ Design Engineer: 0007 Tobben Spurkland, PE Owner Name: Hank Swan Owner Address: 1115 E 80th Ave Anchorage, AK 99518- This permit is for the construction of: [~] Disposal Field r~ septic Tank [] Holding Tank Parcel ID: 015-362-25 Site Address: 1115 E 80th Ave Lot Size: 51749 SQ. FT, Total Bedrooms: 5 Permit Bedrooms: 5 r-~ Privy Private Well r'~ Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only ). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Date: "2~/'~ )0 ~, Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. Permit Number Prope~y owner(s) Mailing address (1) Mailing address (2) Legal description (Lot, Block & Sub'd.) ./-o7' ~. Legal description (Section, Township & Range) LO: Size. '-..-.~'"--/-7 Zl/? Acres~ THIS Day phone. "7'"7'~ - 7q;~ Zip Code C~q ~1~ THIS ~o C.-I/-._ 141L.-L ">/D Number of Bedrooms APPLICATION IS FOR: Sewer Only E~ Well Only Sewer and Well Sewer Upgrade E~ PROPf=RTY CONTAINS: Hot Tub Swimming Pool E~ water softening Unit Therapy Pool I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner o~authorize~ agent) Permit Fees: Waiver Fees: Date of Payment: Receipt Number: (Rev, 12/00) Date of Payment: j~~~;Receipt Number: 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 9950 ! (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 8 BLOCK 2 ROCKHILL S/D HANK SWAN Municipality of Anchorage Development Services Department Building Safety Division On-Site Water and Wastewater Program 4700 Bragaw Street Anchorage, Alaska 99519-6650 February24,2003 We are submitting an application for the installation of a well and septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the well and septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. The septic system design is based on the following: No Ground Water or Impervious Layer to 20 ft. Use Standard Trench Soil Rating. From Testhole 06/05/02 15 rain/in = 0.8 gal per sq.~day No. of Bedrooms 5 Required Area per Bedroom: 150/0.8 = 188 sq.ft. Total area required: 188 x 5 = 940 sqt~ Testhole depth 20 feet Bottom Rock At 14 feet Top Rock At 5 feet Rock Depth 9 feet Minimum Trench Length 940 / 18 = 52 USE 60 FEET SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 60 FT TOTAL WIDTH 2 FT TOTAL DEPTH 14 FT ROCK DEPTH 9 FT COVER 5 FT SEPTIC ANK 1500 GAL The installation of this well and septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration &surface runoffwill not result from this iustallation. . ~ ~/1'. .~'-~~ .,,, ~.. / ~ ....... ~...~..~ rO~EM SPURK~NO P.E. ZOT 8, BLOCK 2 ROC~II, L SIP sEPtiC SYSTE~ DESIeN 20~ ~ 15FH. AVENUE ANCH. AK. 9~501 NANK S~AN DA~E: FEB. ~9, 200~ (907) 279-3916 6500 SHA~ ClRC~ SHE~' l/J GRID: 2~8 PERHIT ~ 2VO3OflXX Piti ff f115-36B-XX RDHO2fl$I. flWG TOBBEN SPUI?KLANO P.E. 205 W 15TN. AVENUE ANCN. AK. 99501 (907) FOR = 49%h C£-{Z225 [LOT BLOCK£NAm swANROCKHILL ~500 SHALE CIRCLE SEPTIC SYSTEkf DESIGN DATE: FEB. 19, 2003 SHEET: 2/3 GRIO: 2~38 PEt?NIT # SVO3OOXX PID # 015-362-XX RLTHO2082.DVG  ~ 0 0 I 0 o St~ndQrd Trench: 68' Long 14' Deep 9.8' Sewer rock! 5' Cover Cleonou~s 9.0 ~* of Septic Rock / II NO SCALE ~03 ~5~h Ave Anchorage Ak 9950~ HANK S~AN ~, FEB. 24, 2002 PER~IT ~ S~O$OOXX PARCEL ID ~ OlS-362-XX RON02OS3.D~G Performed Fcc Legal Description: 8- 9: 11~ 13- 16- 18- 19- 20- COMMENTS t-~o~ Municipality of Anchorage Development Services Department Building Safety Division On-Site Waler and Wastewater Program 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchoraqe:ak.us (901) 343-7904 Soils Log- Percolation Test Slope .f ...'~ ?'-. ,,:', ~, ~'~.., , ,. Date Perf;!rm~d:' Township, Range, Section: Site Plan I WAS GROUND WATER ENCOUNTERED? N 'O IF' YES, AT WHAT DEPTH? L o Depth to Water After p Monitoring? t"J ¥' v~l/ E Reading Date Gross Time Net Time Depth lo Water Net Droc PERCOLATION RATE ~(rninutes~nch) PERC HOL DIAMETER ~ '1 TEST RUN BET~NEEN ~, FT AND ~ FT PERFORMED BY: "7~..5, I /'-~ .~ CERTIFY THAT THIS TEST .WA~ PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPAL GUIDELINES IN EFFECT ON THIS DATE. DATE: ~/:~A Z.