HomeMy WebLinkAboutRATCLIFFE LT 40 Rntcliff e Lot 4 #011- 122-73 1 Municipality of Anchorage'"t �•.; Development Services Department Building Safety Division On -Site Water and Wastewater Program, 4700 S. Bragaw SL P.O. Box 196650 Anchorage, AK 99519-6650 Page I of 3 www.ci.anchorage.ak.us (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT Permit Number: S VI/iD3 0 J PID Number. Name: is Wastewater System: EfNew ❑ Upgrade Address: t 61 le ABSORPTION FIELD Phone: Number of Bedrooms: (f 11beep Trench ❑ Shallow Trench ❑ Bed Cl Mound ❑ Other, LEGAL DESCRIPTION Sol Rating / Total Depth from original gr*7 - GPD1Fs 1'D Fl Block: Lot Subdivision: Depth to pipe bottom from original grade: Gravel depth beneath pipe: 'kA -T C L i if F S S —.51 Ft. 15 FL Township: Range: Section: Fill added above original grade: Gravel Length: LI Fl. J Fl. Well: ❑ New ❑ Upgrade Gravel width: Number of lines: II Distance between lines: Ft. Ft. Classification (Private, A B, C): Total Depth: Cased to: Total absorption area: 1J CSD Pipe Material: Ft. Ft. Fl= 811D [ 3d Driller. J _f i NV Date Drilled: Static Water Level: Installer. Date Installed: 1Y Ft. Cc 1 M ^ +J ^D 3 Yield: Pump Set at Casing Height Above Ground: TANK GPM FL FL SEPARATION DISTANCES [�(Septic ❑ Holding ❑ S.T.E.P. ❑ Other. To Septic Absorption Lift Holding PubliclPrivat Manufacturer. Capacity. From Tank Field Station Tank Sewer Line AML�H- —,&N I X L)Gal. Well A � L) � GTA CE Material: S7 i_ k I — Number of Compartments; !-- SurfaceWater nLIFT ST TION Lot Line i +� f7 Size: Gat, Manufacturer. 'Pump on' level at: 'Pump off'le I at High water alarm at: Foundation 7 t d 1n, in. In. Curtain Drain Pump Make S Model Electrl Inspections performed by: Remark; BENCH MARK Location and Description: Bc)T1ur-4 S1DfNH Assumed Elevation: IAC-- FL �Er�ginee. � :;� 0oe90o non i ?'L oo hr °•o r YJ - Inspections performed by: Dates: 1't 9!510 000icoc"ae��osr _'— c do 2nd 9 °poo uw wJWwO N �• Development Sehices Department Approval TO Reviewed and approved by: Date: to ���j4FF°°tee V (Rev. 12/00) G7 -------------- -----------I-- -- -- --- - -- -- --- /-- �r- - W-- -/- - - �/- - SYSIE�I ► MARK RS BENCH%K. SEPTIC AREA BOTT017 SlDI1 ASSUMED ELEV. L.00 FT TOBBEN SPURKLAND P.E. L0T 4 RATCMFFE SID SEPTIC SYSTEM AS BUILT 203 W 15TH. AVENUE DA 7E.- OCT. 10, 2003 ANCH. AK. 99501 TIMBERLINE HOMES ,,,,,.,, AK. 950 6961 WEST K£NDALE CIRCLE SHEET. 2/3 GRID: 2222 I PERMIT #SW030221 PID # 011-122-73 RAT00042.DWG V. .m Standard Trench, 2' Wide 50' Long 8' Beep 5.0' Sewer rock 3' Cover S1l t Ba NO SCALE 0 Monl for Cleanouts - 3' Cover 96t z Cs Qi V n, I 1250 gal Septic tank 90.8 85.6 V 0 5.0 Ft of Septic Rock Effective 1250 gal, septic tank 81 H2O 6-10-03 NO SCALE 79 RENCH MAN B07TOM SIDING AS BUILT ASSUMED ELEV 100.00 FT TOBBEN SPURKLAND P.E. LOT 4 RATCLIFFE SID SEPTIC SYSTEM SCHEMATIC 203 W15th Ave DATE TIMBERLINE HOMES OCT. 10, 2003 Anchorage Ak 99501 P79 -191A 11 6961KST KFNDALE CIRCLE SHEETi 313 GRID 2,022 PERMIT SWO30221 PARCEL ID / 011-122-73 RAT00043.DWG g�s)D3 MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 South Bragaw Street P.O. Box 196650, Anchorage, AK 99519-6650 (907) 343-7904 ON-SITE WASTEWATER DISPOSAL SYSTEM PERMIT Initial Permit Number: SW030221 Legal Descriptiorl"Ratdliffe7Lot 04— Design Engineer: 0007 Tobben Spurkland, PE Owner Name: Justin Ripley II Owner Address: PO Box 221893 Anchorage , AK 99522 - This permit is for the construction of: ]✓ Disposal Field F✓ Septic Tank �toY-V\ 3Pryv Date Issued: Jun 25, 2003 Expiration Date: Jun 24, 2004 Parcel ID: 011-122-73 Site Address: unknown Lot Size: 43305 SQ. FT. Total Bedrooms: 4 Permit Bedrooms: 4 0 Holding Tank E] Privy [—] Private Well [] Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal Code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations ( 18AAC72 ) and Drinking Water Regulations ( 18AAC80 ). 3. The engineer must notify DSD at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 ( 24 hours ). ( Not required for a Water Supply Permit only). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must be either: A. Open and closed on the same day. B. Covered, sealed, and heated to prevent freezing. Received By: Date: ! d 3 Issued By: I�. ��� Date: 6-257-0-7 Municipality of Anchorage **6[ eb♦ • Development Services. Department j Building Safety Division _: On -Site Water and Wastewater Program s A IT. 4700 South Bragaw St. P.O. Box 196650 Anchorage, AK 99519-6650 www.ci.anchorage:ak.us (907) 343-7904 ON-SITE SEWER/WELL PERMIT APPLICATION FOR A SINGLE FAMILY DWELLING Parcel I.D. -�) Z� . '—� Permit Number SW Property owner(s) 1� 1--� y Day phone Mailing address (1) F6 `sby, ZZi Req Mailing address (2) 1 Zip Code Legal description (Lot, Block & Sub'd.) LO 1 4, V_A_t C L Legal description (Section, Township & Range) Lot Size q S. 3 fl_5 Acres/Sq.Ft. . Number of Bedrooms L4 THIS APPLICATION IS FOR: Sewer Only [J Well Only. ❑ Sewer and Well ❑ Water. Storage ❑ Sewer Upgrade ❑ THIS PROPERTY CONTAINS: Hot Tub ❑ Jacuzzi ❑ Swimming Pool ❑ Water Softening Unit ❑ Therapy Pool ❑ I certify that the above information is correct. 1 further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authoriled agent) Permit Fees: -�' y� Waiver Fees: Date of Payment: bb -3k3 Date of Payment: Receipt Number: '3 % q5 '-/ Receipt Number: (Rev. 12/00) T o0.YP 6 lld VD P.E. 203 W 15th. Avenue, Suite 203 ANCHORAGE, ALASKA 99501 (907) 279-3916 Fax (907)-276-6013 SEPTIC SYSTEM DESIGN LOT 4 RATCLIFFE S/D TIMBERLINE HOMES Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 Bragaw Street Anchorage, Alaska 99519-6650 June 21, 2003 We are submitting an application for the installation of a septic system for this lot. The submittal consists of three (3) drawings showing the present improvements on the lot and the adjoining properties, (sheet 1/3), the proposed improvements of the lot, of which only the septic system is subject to this permit application, (sheet 2/3), and a schematic of the septic system, (sheet 3/3). Soil logs and percolation tests of applicable testholes are also enclosed. This subdivision is served with public water. (AWVAJ) The septicsystem design is based on the following: Ground Water at 14 feet on June 10, 2003 Running, unstable sand. . Use Standard Trench Soil Rating. From Testhole 05/20/03 <1 min/in =1.2 gal per sq.ft/day No. of Bedrooms 4 Required Area per Bedroom: 15011.2 = 125 sq.ft. Total area required: 125 x 4 = 500 sgft Ground water at 14 feet Bottom Rock At 8 feet Top Rock At 3 feet Rock Depth 5 feet Minimum Trench Length 500 /10 = 50 ft. SYSTEM CONFIGURATION STANDARD TRENCH TOTAL LENGTH 50 FT TOTAL WIDTH 2 FT TOTAL DEPTH 8 FT ROCK DEPTH 5 FT COVER 3 FT SEPTIC ANK 1250 GAL The installation of this septic system will not prevent wells and septic systems from being installed on the adjacent lots. There are no developed or natural surface / sub surface drainage courses on this or the adjacent lots. The proposed septic system will not change the general slope of the area. Ponding and/or concentration of surface runoff will not result from this installation. UNBEVEL17PED — -------------------------- - r------------- - - - - -- - - I I 1 2 I I I I III I I I I I � I— — — — "n cam VEST KENDALE CIRCLE W I � I I I � I I I \ I II I it I I 1 1L I 7 I I I I �•,¢j'�, L- - - - -- -- - -----���•, A cf�$ 50 0 50 l00 150 200 250 300 SCALE, I' = 100 FT, I I I I I I I I I I I TOBSEN SPURKL4ND P.E. LOT 4 RA MFFE SID SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE TIMBERLINE HOMES WE: JUNE 20, 2003 ANCH. AK. 99501 6961 WEST KENDALE CIRCLESHEET- 1/3 GRID: 2222 /ons) 970_;Wa PERMIT #SV03OXXX PID # XXX RAT00041,DV5 I TOBBEN SPURKLAND P.E. LOT 4 RAMMME S/D SEPTIC SYSTEM DESIGN 203 W 15TH. AVENUE DATE: JUNE 20, 2003 ANCH. AK. 99501 TIMBERLINE HOMES 6961 WEST K£NDALE CIRCLE SHEET 2/3 GRID: 2222 I PERMIT #SV03OXXX PID # XXX 1./0//SF //AInF"R rnNISTR!lrTl&T00042,DWG Standard Trench. Sil t Ba 5.0 ft or Se Effective 0-0do O _O O � � 0 1250 gal Septic tank o C a A t2 2' Wide 50' Long 8' Beep 30' Cover rock Sewer . +'v%W' �G OF '• 49th s . TCHBEtJ SPURKLAND I fJnj 11: No. CE -2225 NO SCALE �1••''........ 4i -PR6 ITU >L.HLG SPURKLAND P.E. 203 W15th Ave LOT 4 RATCLIFFE SID SEPTIC SYSTEM SCHEMATIC 203 W1 Anchorage Ak 99501 TIMBERLINE HOMES DATE, JUNE 21, 2003 6961WEST KENDAIE aRCLE SHEETS 3 3 GRID 2222 PERMIT I SW0300XX PARCEL ID / XX RAT00043.DWG O •� Performed For: Legal Description: Arucy Municipality of Anchorage Development Services Department Building Safety Division On -Site Water and Wastewater Program 4700 South Bragaw Sl. P.O. Box 196650 Anchorage, AK 99519-6650 www ci.anchorage.ak.us (907) 343-7904 Soils Log - Percolation rest ' t' Date.Performed: �f4Zp/o 3 Township, Range, Section: Site Plan 4- _ (-OUese rd� `e,1� 10. -� i1- f t 12- 4 t 1 I. - 1A. i�• `% � �lz.o�a� 16 BeiTcCA a (� ,7- V 1�- 20- CCi`."MENTS PEc,"CLATION PATE L lr. cnaei5rtl) FERC FCL E CIA.MUER (p " TEST RUN 9ETPIEEN �j FT PUD FT PER FCRI IED BY: S I �i CERT IFY THAT THS TEST "':.c PERFORMED ISI ACCORDANCE WITH ALL STATE AND ..UN1CIPAL GUIDELINES IN EFFECT ON I T'i!S DATE. DATE; to 'to O E?:CCS`: T E=E7? ys IF YES. AT WHAT DEPTH? ! L 0 Depth to vla:er AfterJ P 14 Monitoring? E G1r0103 Dale: PEc,"CLATION PATE L lr. cnaei5rtl) FERC FCL E CIA.MUER (p " TEST RUN 9ETPIEEN �j FT PUD FT PER FCRI IED BY: S I �i CERT IFY THAT THS TEST "':.c PERFORMED ISI ACCORDANCE WITH ALL STATE AND ..UN1CIPAL GUIDELINES IN EFFECT ON I T'i!S DATE. DATE; to 'to O lk4unicipality of Anchorage Development Services Department • / Building Safety Division p r4• On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650(� Anchorage, AK 99519519-6650 �`- www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL FOR A SINGLE FAMILY DWELLING Parcel I.D. V I' Io�o�— COSA# Oq 09 43� 1. GENERAL INFORMATION Expiration Date: Complete legal description Location (site address) Current Property owner(s) Mailing address Lending agency Mailing address Real Estate Agent Mailing address RATCLIFFE LOT 4 6961 WEST KENDALE CIRCLE *ANCHORAGE, AK JUSTIN RIPLEY Day phone 240-7565 6961 WEST KENDALE CIRCLE 'ANCHORAGE, AK_ Unless otherwise requested, COSA will be held by DSD for pickup. 2. NUMBER OF BEDROOMS: 4 Day phone Day phone 3. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well ❑ Individual On-site Individual Water Storage ❑ Individual Holding tank ❑ Community Class Well ❑ Community On-site ❑ Public Water System Public Sewer ❑ The Municipality of Anchorage Development Services Department (DSD) Issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 4 by an independent professional civil engineer registered in the State of Alaska. Certificates of On -Site Systems Approval are required for the transfer of title (except between spouses) for properties served by a single-family on-site wastewater disposal and/or water supply system. DSD also issues COSAs upon request to homeowners. Certificates of On -Site Systems Approval are valid for 90 days from the date of issue for properties served by a private or Class C well and may be reissued with new water samples. (Certificates may be reissued for a period of up to one year with valid water samples.) Certificates are valid for one year for properties served by Class A or B wells or a public water system. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 4. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-siie water supply and/or wastewater disposal systen is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage riles and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm GARNESS ENGINEERING GROUP, Ltd. Phone 337-6179 Address 3701 E. TUDOR ROAD, SUITE 101 • ANCHORAGE, AK 99507 Engineers Printed Name JEFFREY A. GARNESS, P.E. Date -7]2 � 09 Engineers Comments: In conducting this evaluation, GEG, LtD. attempted to provide a thorough, conscientious engineering analysis of the system in accordance with ADEC and MOA DSD Guidelines 8 Regulations. The reported results described the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identirrable features. The operational life of all wells and septic systems depend on the local soils condition, groundwater levels that may fluctuate during the year, and the water usage of the family being served by the system. These conditions are outside the control of the evaluator of the system. Satisfactory test results do not guarantee future performance of the system, nor do they guarantee that there are no hidden defects or encroachments. GEG, LTD. can therefore not provide any warranty or future estimate of how long the system will continue to meet the operational requirements of the ADEC or MOA DSD. The content of this report Is for the sole benefit of the owner listed above. Any reliance upon or use of this report by any other person or party is not authorized, nor will it confer any legal right whatsoever. S. DSD SIGNATURE Approved for bedrooms. Disapproved. �y04......... ); g 9� e .� .. A.....ness.: E-7953 Conditional approval for bedrooms, with the fllowing stipulations: Attachments: / COSA Checklist Septic System Advisory Well Flow Advisory Nitrate Advisory Arsenic Advisory Maintenance Agreements Supplemental Engineers Report Other .�;y, ' ••,.o ON-SITE WATER AND WASTEWATER PROGRAM ' By; Original Certificate Date: 7-2) ` o (Rev 11105( D. LIFT STATION Date Installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off" leve High water alarm level at in. Cycles tested Meets alarm & circuit requirements? E. SEPARATION DISTANCES SEPARATION DISTANCES FROM WELL ON LOT TO: Septic tank/lift station on lot On adjacent Absorption field on lot Public sewer main Sewer /septic service line On adjacent lots Holding tank manhole/cleanout Animal ent areas Manure/animal excrete storage areas SEPARATION DISTANCES FROM SEPTIC/HOLDING TANK ON LOT TO: Building foundation 5'+ Property line 5'+ Absorption field 5'+ Water main 10'+ Water service line 10'+ Surface water 100'+ Wells on adjacent lots 100'+ SEPARATION DISTANCE FROM ABSORPTION FIELD ON LOT TO: Property line 10'+ Building foundation 10'+ Water main 10'+ Water service line 100+ Surface water 100'+ Driveway, parking/vehicle storage 10'+ Curtain drain NONE KNOWN Wells on adjacent lots 100'+ F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that l have determined through field Inspections and review of Municipal records that the above systems are in contormance with MOA COSA guidelines in effect on this date. Engineer's Printed Name JEFFREY A. GARNESS Date :2 1Y4/o9 COS A Fee S 1 q o Date of Payment % 1-7 f u ry Receipt Number 0.L l g 9 3 (Rev. 11/05) Waiver Fee $ Date of Payment Receipt Number Municipality of Anchorage Development Services Department Building Safety Division On -Site Water & Wastewater Program 4700 Bragaw Street P.O. Box 196650 Anchorage, AK 99519-6650 www.muni.org/onsite (907)343-7904 CERTIFICATE OF ON-SITE SYSTEMS APPROVAL CHECKLIST Legal Description: RATCLIFFE LOT 4 ParcelID: %3 A. WELL DATA PUBLIC WATER Well type If A, B, or C provide PWSID# _ Well Log (YIN) Date completed Sanitary seal (YIN)_ Wires prop>(abo ted (YIN Total depth ft. Cased to ft. Casing heiround) in. FROMWELL LOG ATI CTION Date of test Static water level Well production g.P.m. 9•p•m- WATER SAMPLE RESU Coliform colonies/100 ml. Nitrate mg./L. Other bacteria colonies/100 ml. ic: ug./L. Date of sample: Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material SEPTIC/STEEL Date installed 9/5/03 Tank size 1250 gal. Number of Compartments E Cleanouts (YIN) YES Foundation cleanout (YIN) YES Depression over tank (YIN) NO High water alarm (YIN) N/A Date of pumping 4/30/09 Pumper NORTHLAND PUMPING C. ABSORPTION FIELD DATA Date installed 9/5/03 Soil rating (g.p.d./ft2o /bd 1.2 System type TRENCH Length 50 ft. Width 2 ft. Gravel below pipe 5 ft. Total depth * 10.58 ft. Eff. absorption area 500 ft' Monitoring tube YES Depression over field NO Date of adequacy test 7/23/09 Results (Pass/Fail) PASS For 4 bedrooms Fluid depth in absorption field before test? in. Water added 790 gal. New depth? in. Elapsed Time: 0 min. Final fluid depth? in. Absorption rate >= 600+ g.p,d- Any rejuvenation treatment (past 12 mo.) (YIN & type) NONE KNOWN If yes, give date — Q00000000 o Tract A od �EOF.At°44 ...... .. gs40 O �i�9 TF00�� ............. 0 �. p�1... .........� .. DO 00 •, h0 y offir QO`" y5-90 0 ao� e l/ 4� ♦a ye33i0^aT \'per' �0�0000�� 1 1 a e � I 1 I o Lot 3 tm e� r I � Doi m m m 0 O o LOT 4 " w i i rl fTl m Iz Pr' p5.0 .0 PVA LAN 13.7 J 41v • � I A i0 ^Q r al C 6.8 7 Hol Tub\ s a r? o a. r 1 Paved Drive 1 I `\�s N WESTJr `1 0 �. �______________________________ -"""---'e ________________________i __ KENDALE LA. p.0 f0 20' UTILITY AND PUBLIC TRAIL EASEMENT CIRCLE 0 Path 589'49'56"W 227.22 / Lot 5 NOTE: THIS DRAWING IS NOT TO BE MODIFIED FOR USE AS A PLOT PLAN WITHOUT THE EXPRESSED WRITTEN CONSENT OF LANTECH. Legal Description: Ordered By,. Justin Ripley AS -BUILT Legend: Lot 4 s Ratcliffe Subdivision Septic Standpipe QS Water Well AsDhdl !i!ii Centrals ,,,.,,fDseh°^g.,'.: Fence—X—X° Wood Deck G- SURVEY CERTIFICATION: LANTECH has conducted o physicalof s property s shown on We dro*ing and certifies that the improvements shoaled therem we within the property lines and no encroachments exist other than noted. LAND & CONSTRUCTION SURVEYORS—PLANNERS—ENGINEERS EXCLUSIONARY NOTE: It Is the owners' responsibility to determine the existence of any easements, covenants, restrmions or right-of—way 440 West Benson Anchorage. Alaska Boulevard, Suite 200 Phone: 99503 562-5291 takings which do not appear an the recorded subdivision plot. Under no clrcumstonces should any data hereon be used for construction, Fax: 561-6626 far establishing property Ivies, or for plot-pton purposes. Plot: 2002-131 arld: SW 2222 Dale: July 22, 2009 Drown By. CB Werk Order: 2003•—L-214 fb/Pg: 749/10-11 seole: 1'-40' lChecked By. JMZ