HomeMy WebLinkAboutT15N R1W SEC 18 LT 74ZO-ZL I - 1 0# tL 10'I 81 aS Municipality of Anchorage On-Site Water and Wastewater Section • (907) 343-7904 Page 1 of 1 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP191379 PID Number: 051-172-02 Dwelling: ❑® Single Family (SF) ❑ with ADU ❑ Duplex (D) ❑ Two Single Family Project: ❑ New X Upgrade Name Zachary Browning ABSORPTION FIELD ❑ Deep Trench ❑ Wide Trench ❑ Bed ❑ Mound Site Address 19338 Becky Lane, Chugiak, AK 99567 ❑ Other Phone INumber of Bedrooms Soil Rating Total depth from original grade REALTOR*: 907-232-4852 3 GPD/SF Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Ft. Gravel depth beneath pipe Ft. Subdivision Block Lot 74 Fill added above original grade Ft. Gravel length Ft. Township Range Section 15N 1W 18 Gravel width Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line Ft2 Ft. Well >100, TANK ❑®.Septic ❑ S:T.E.P. [:]Holding ❑Other Manufacturer Greer Capacity 1250 Gal. Surface Water >100' Material Polyethylene Number of compartments 2- i Lot Line I >5' ' NA Foundation >1 Q' I LIFT STATION Manufacturer. Capacity Remarks •Owner recently moved out of the country and does not have a permanent phone number yet. Gal. Alarm location Electrical installed by PIPE MATERIAL House to tank 3034 drainfield Tank to 3034 Installer RPC - Richard Person Construction Drainfield ' CO/MT3034 Inspector Crewdson Engineering LLC BENCH MARK (Assumed elevation) 100 , ft Inspdates;ection ist 9/10/2019 d 9/11/2019 Location and description 2 3ru 4th Top of porch slab, see record drawing ON-SITE WATER AND WASTEWATER SECTION APPROVAL Engineer's Stamp.. A4,1 Conditional Approval: Date --------- -- .�.1 James A, Crewdson ; = Septic System011527 Appro �i,_Z2L Date 0 , C, i I ��i, '�= Note: this does include \\\OFESS`�P=� approval not well permit requirements. (rcev ub/uu1 6) A L LC 11\11'49 SWING TIES (feet) A B MH 66.90 69.20 S1 71.52 72.96 DC 74.28 75.25 o WELL NOTES 1. (E) SEPTIC TANK REMOVED AND DISPOSED JAW THE CODE. 2. NO DRAINFIELD ROCK FOUND WITHIN 5' OF THE (N) SEPTIC TANK. Civil & Environmental Engineering PO Box 671389 Chugiak AK 99567 . ce11c.1 @ou0( Cellfrext:907-280-9493 . Fax:907-888-2295 BENCH MARK ELEV TOP OF SLAB AT "BM" EG 99.1' ASSUMED ELEV 100' FG 99.7' 2" INSULATION SEPTIC TANK GREER 1250 PE ELEV: TOT 95.58' INLET INV 94.62' OUTLET INV 94.45' PLAN PROFILE SCALE: 11'=30' NOT TO SCALE T1 5N, R1 W, Sec 18, Lot 74 Septic Tank Upgrade Record Drawing Plan and Profile Views Prepared for: Zachary Browning Date: 9-11-19 Permit: OSP191379 Page: 1 of 1 ALL INFORMATION SHOWN ON THIS DOCUMENT IS THE PROPERTY OF CREWDSON ENGINEERING. LLC AND SHALL NOT BE USED FOR ENGINEERING OR CONSTRUCTION PURPOSES YATHOUT WRITTEN PERWWOH FROM CREWDSON ENGINEERING. LLC LEGEND (E) -.existing . (N) - proposed BM - benchmark BR - bedroom DC - double cleanout EG - existing ground ELEV - elevation FC - foundation cleanout FG - finish grade IAW - in accordance with INV - invert MH - 24' manhole MIN - minimum PE - polyethylene PL -,property line S# - septic tank cleanout SFH single family home TOT top of tank F.. moi,, %\ �. James A. Crewdson C11527 �a®_ pROFESSIOHP o. ALLC #112279 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191379, Deb Wockenfuss, 08/28/19 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COMPLIANCE OSP191379, Deb Wockenfuss, 08/28/19 MUNICIPALITY OF ANCHORAGE DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION ENVIRONMENTAL ENGINEERING DIVISION 825 L Street · Anchorage, Alaska 99501 Telephone 264-4720 ON-SITE SEWAGE DISPOSAL SYSTEM AND/OR WELL INSPECTION REPORT ~MAIL NG ADD ESS LEGAL DESCRIPTION LOCATION DISTANCE TO: ]Well j j (~ , I Ab~rptip a,ea Manufacturer ~ IF HOMEMADE: Inside length Width Well Dwelling DISTANCE TO: Manufacturer NO..~EDROOMS PERMIT NO. No. of co~rtmonts liquid depth PERMIT NO. Material Liquid capacity in gallons DISTANCE TO: Well lA ~ Found~jorl~.~. Nearest~line! each line No. of lines / O Top of tile to finish grade ~ ~ Material beneath tile Depth Crib diameter Crib depth Well ~ Building foundation Depth Driller Building foundation Sewer line Length ~_ Width Type of crib DISTANCE TO: Class DISTANCE TO: PERMIT N( Distance between lines inches Total effective absorption area Nearest lot line Septic tank Distance to lot line area OTHER PIPE MATERIALS 0 INSTALLER REMARKS DATE LEGAL PERM!T NO. RPPLICANT _OCATION _EGAL I"IUI'-.I ! f-' ! ~ F-IL ! T%-" I'--mF AI'-.I~SI-t,_.~f~:AGE: DEPFtRTMENT OF MEFILTH FIND ENVIRONMENTAL PROTECTION 825 "L'" STREET, C~l".l--S I TE < ?SlOii ) CHFIRLES R. FERRIN L?4 Si8 TiSN RIW SM 8NC:HORFIGE., 264-47'20 ......... ' PO BOY, 927 ERGLE RIVER 688 269~ LOT SIZE i100oo SQURRE FEE"[' TYPE OF SOIL RBSORBTION SYSTEM IS: TRENCH ~RXIMUM NUMBER OF BEDROOMS SOIL RFITING (SQ FT?BR)= 2]:5 I'HE REQUIRED SIZE OF THE SOIL FIBSORPTION SYSTEM IS: DEF"'TH= .'1_0 LENGT'H= 5-~- '3RR~'EL, D E: F"T I'"'1 ~== - ~' ~' .JR DR. FIINFIEL[:L THE LENGTH DIMENSION IS THE LENL]TH (IN FEET) OF ]'HE TRENCH r ' THE DEPTH OF FI TRENCH OR PI"[' IS THE DISTFINCE BETWEEN THE SURFFICE OF: TH[.'". GROUND FIND THE BOTTOM OF THE E%CFIVFITION (IN FEET). THERE IS NO SET WIDTH FOR TRENCHES. ]"HE GRRVEL DEPTH IS THE MINIMUM DEPTH OF GRRVEL BETWEEN THE OLITFFILL F'IF'E FIND THE BOTTOM OF THE EXCBVBTION (IN FEET). E;: EEI;~L.I I REL~ SEPT I C: TFif-4f{ S; I ZE=: :t [ZIO[Z~ (!iR L.L.C'.".dF,,IE~; ='ERMIT FIPPLICFINT HFIS THE RESPONSIBILIT'¢ "['0 INFORM THIS DEPRRTMENT DURING THE INSTRLLRTION INSPECTIONS OF 8NV WELLS FIDJRCENT TO THIS PROPERTY F¢4D THE NUMBER OF RESIDENCES THPIT THE WELL WILL SERVE. ........ TI-lin] ( 2-:: ) I I%iSPE'EC:'I- I 01'-4 :E; RRE F.,~E (-.~lJ I I~..:EE::[: .......................... BRCKFILLING OF FINY S'¢STEM WITHOUT FINFIL INSPECTION FIND 8PF'ROVFIL BY THIS DEPRRTMENT WILL BE SIJBJECT TO PROSECUTION. MINIMUM DISTRNCE BETWEEN B WELL RND FINY ON-SITE SEWRGE DISPOSRL SYSTE:M IS 100 FEET FOR FI PRIVFITE WEL. L.~ OR 150 TO 2.00 FEET FROM R PUBLIC WELL DEPENDING UPON THE TYPE OF PUBL. IC WELl :,PE61F I L..RT I ON=, 8ND CONSTRUCT I ON D I FIGRRMS FIRE: OTHER REL4UIREMEN"[_ MFIY FIPPLY. FIVFIILRBLE TO INSURE PROPER INSTFILLRTION. F'EERM I -i- E ;--', F" I RE~; DEE:Er'IBER ~:.'1.... I CERTIFY THFIT :.1.: IRM FFIMILIFIR WITH THE REQUIREMENTS FOR ON-SITE SEWERS FIND WELLS FIS SET FORTH B'.r' THE MUNICIPFILIT"r' OF' FINCHORFIGE. 2: I WILL INS"I"FIL. L THE SYSTEM IN FICCORDFINCE WITH THE CODES. 2~: I UNDERSTFIND THFIT THE ON-SITE SEWER SYSTEM MRY REQUIRE ENLFIRGEMEi'.,I"F IF' THE RESIDENCE IS REMODELED TO INCLUDE MORE THFIN Z< BEDROBMS. ',,,':ii:. 2 O ~ E GEC ECHNICAL ~' DEVEL ,PMENT CO. Box 90, Davis St., Eagle River, Alaska 99577 694-2774 or 688-2280 Russell Oyster Earl Ellis 694-2774 S0[~. LOG 688-2280 Soils Et Foundations Land Development Performed for: Name: Legal Description: Z~r ~ ~. ~c./~ 'TI~ ~IVV~ ~.~f. Depth, (feet) Sot] Char~cter1~,t1~ 0 2 6 12, 13 ~ ~-~ 14, 16 Ground Water Encountered: Yes Proposed Installation: Seepage Pit Comments: No / If yes, what depth , Drain Field Date: MUNICIPALITY OF ANCHORAGE Development Services Department Phone: 907-343-7904 On -Ste Water & Wastewater Section Fax: 907-343-7997 Certificate of On -Site Systems Approval Parcel I:D. 051-172-02 1. GENERAL INFORMATION Expiration Daw- Complete legal description T1 5N, R1 W, Section 18, Lot 74 Location (site address) 19338 Becky Lane, Chugiak, AK 99567 Current property owner(s) Zachary Browning Day "phone contact realtor Mailing address contact realtor at: 603 W Recon Circle Palmer, AK 99645 Real estate agent .Jay Van D'lest Day 'phone 907-232-2358 2- TYPE OF DWELLING:- WELLING:Single SingleFamily (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3... NUMBER OF BEDROOMS: 3 . 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Private Well [] .Private Septic Q `Water Storage ❑ Holding Tank ❑ Community Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver request for: Distance: Received by: Date: COSA. to be released to the engineer, unless otherwise requested by the engineer. COSA Fee $ JrsJ Waiver Fee $ Date of.Payment Date of Payment Receipt Number Receipt Number COSA # LIS 14 Ic/28 Waiver # . 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed, hereto. and as of the validation date shown below,, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application,, shows that the on-site water supply .and/or wastewater disposal systemis (are) safe, functional. andadequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage. files and from. my investigation and inspection, the on-site water supply and/or wastewater disposal system is (are) in compliance with all applicable Municipal and.State Codes, ordinances, and regulations in effect at the time of installation. Name of Firm Crewdson Engineering, LLC Phone 907-280-9493 Address PO Box 671389, Chugiak, AK 99567 Engineer's Printed Name James.Crewdson Date 9/11/201.9 ALLC 11 N201.9 i F A 4 ,' 6. DSD SIGNATURE System #1 Approved for bedrooms � , , , �• , , , , / JamesA.Orewdwn System #2 Approved for bedrooms / �' • ,�► C11517 : � Disapproved �` F�'• •�'�,f Conditional approval for bedrooms, with the following stiA�i�d�R�� w OF AA�,��/��, ByOriginal Certificate date.M ` The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist . X Nitrate Advisory Septic System Advisory Arsenic Advisory; Well Flow Advisory Other COSA Checklist blue sheet Legal Description: T15N, R1 W, Section 18, Lot 74 If more than 1 septic system on lot: COSA Checklist # of A. WELL DATA ❑ Well log is filed with Onsite (or attached) Date drilled UNKNOWN Total depth '40 ft Cased to UNKNOWN ft ❑ Sanitary seal is functioning correctly ❑ Wires are properly protected Casing height (above ground) '18 in. Date of flow test for COSA W212019 Static water level at beginning of test 46 ft. Comments B. TANK DATA Age of tank(s) 0 years Tank type/material SeptfdPE ❑ Standpipes/foundation cleanout per record drawing Date of pumping not required D. ABSORPTION` FIELD DATA Which system tested.(date installed) 1/911978 ❑ ALL standpipes, present per record drawing Total measured depth:from grade 10 ft (max) Measured depth to pipe invert from grade 4 ft (min) ❑ N/A — pressurized field ❑ Monitor tubes go to bottom of drainfield. If not, state depth into effective ❑ Code -required soil cover over field ❑ System presoaked (Required if vacant for greater than 30 days prior to date of test) Gallons introduced gallons Comments/Deficiencies: COSA Checklist yellow sheet Parcel ID: 051-172-02 Structure served by this system Well production at time of test 6+ pm Water Water storage tank volume NONE gallons Well disinfected for coliform test? ❑ Yes IN Nc ❑ Coliform bacteria is Negative Nitrate mg/L ❑ Nitrate less than MRL (ND) Arsenic ug/L ❑ Arsenic less than MRL (ND) Collected by Crewdson Engineering Date of Sample a22"0'9 G. LIFT STATION ❑ Required maintenance completed Age of lift station years Lift station material Comments: Adequacy test date 8r'2'20'9 . Results Q Pass For 3 bedrooms Fluid depth prior to test 30 in Water added 450+ gat New depth 38 in Elapsed time `1440 min Final fluid depth 30 in Absorption rate 450+ gpd Any rejuvenation treatment (past 12 months) If yes, enter date E. SEPARATION DISTANCES From Private well on Lot to: (Please enter distances if less than required or if community well) Septic Tank/Lift Station on Lot > 100' ® Yes if No Community Sewer Manhole/Cleanout > 100' 0 Yes if No ft 0 Yes if No ft Neighboring Tank > 100' ®Yes if No ft Private Sewer/Septic Line > 25' ✓❑Yes if No ft Absorption Field on Lot > 100' ✓Q Yes if No ft Holding Tank > 100' ✓Q Yes if No ft Neighboring Absorption Fields > 100' Water Main > 10' Animal Containment > 50' ® Yes if No ft 0 Yes if No ft if No ft Water Service Line > 10' Q Yes if No ft Manure/Animal Excreta Storage > 100' 0 Yes Community Sewer Main > 75' [Z] Yes if No ft Yes if No ft From Septic/Holding Tank on Lot to: (Please enter distances if less than required) Building Foundations > 10' ® Yes if No ft Surface Water > 100' ® Yes if No ft Property Line > 5' Yes if No ft Driveway/Parking > 0' Q✓ Yes if No, comment Absorption Field > 5' OYes if No ft Wells on Adjacent Lots: Water Main > 10' ® Yes if No ft Private Wells > 100' Q✓ Yes if No ft Water Service Line > 10' Q Yes if No ft Community Wells- 200' 0 Yes if No ft From Absorption Field on Lot to: (Please enter distances if less than required) Building Foundation > 10' Q Yes if No ft Driveway/Parking >. 0' 2✓ Yes if No, comment Property Line > 10' Q Yes if No ft Wells on Adjacent Lots: Water Main > 10' 0✓ Yes if No ft Private Wells > 100' Q Yes if No ft Water Service Line > 10' FV� Yes if No ft Community Wells > 200' Q✓ Yes if No ft Surface Water > 100' Q Yes if No ft F. ENGINEER'S COMMENTS Onsite records allow the drainfield to extend into the section line easement. G. ENGINEER'S CERTIFICATION 1 certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. COSA Checklist yellow. sheet A 4.10 O�PROFESS���'�~ • Municipality of Anchorage On -Site Water and Wastewater Program (907) 343-7904 Parcel I.D. Certificate of On -Site Systems Approval 051-172-02-000 Expiration Date: al .OLS:, 7 LujS 1. GENERAL INFORMATIONI till Complete legal description T15N R1 W SEC18 Lot 74 Location (site address) 19338 Becky Lane, Chugiak, AK 99567 Current Property owner(s) Roberta Kolb Day phone 688-5261 Mailing address 19338 Becky Lane, Chugiak, AK 99567 Real Estate Agent Amy Vik Day phone 244-3355 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Fx I Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: /,, Received by: tzii( �/�f l /!'�Ii� Date: �� y COSA to be released to the engineer, unless otherWse requested by the engineer. COSA Fee $ 11216)-G — Date of Payment u-1 [�'� Receipt Number �i�``�r0Cp7 COSA# OSC���'LGo Waiver Fee $ Date of Payment Receipt Number Waiver # 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On -Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Anderson Engineering Address P.O. Box 240773 Anchorage, AK 99524 Engineer's Printed Name Benjamin Schiller, P.E. 6. DSD SIGNATURE Phone 522-7773 Date 9/12/2016 OF 44��o ION ° _Y 4'.sr-0 9 18 System #1 Approved for bedrooms Y pP System #2 Approved for bedrooms HSV CE j''�2 0 °ten Disapproved m6O'���� FESS16f� ®®m Conditional approval for bedrooms, with the following stipulat By: i 1 =E3(�� Original Certificate Date: The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On -Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. ATTACHMENTS:. COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f .. c If more than 1 septic system is on the lot: COSA Checklist # of Structure served by this system Certificate of On -Site ,Systems Approval Checklist Legal Description: T1_4N R1 W Sed 8 Lot 74 Parcel ID: 051-172-02-000 A. WELL DATA Well type Private If A, B, or C provide PWSID # Date completed Unknown Sanitary seal (Y/N) Y Total depth >40 ft. Cased to Unknown ft Date of test Static water level Well production FROM WELL LOG Unknown Unknown ft Well Log (Y/N) N Wires properly protected (Y/N) Y Casing height (above ground) 24.5 in. AT INSPECTION 9/30/2016 49.71 ft. Unknown 9 -P.M. 4.383 9 P.M. WATER SAMPLE RESULTS Coliform O �onies/100 mL Nitrate ND mg/L Arsenic ND ug/L Date of sample: 9/27/16 Collected by: And. Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/Steel Tank size 1,000 gal. Number of Compartments 2 Date installed 11/12/78 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping 10/01/20,16 pumper Sanitary Pumpers C. ABSORPTION FIELD DATA 1'/9/7$ z z 235 sf/bdrm Trench Date ins�taylled' =t Soil rating (g.p.d./ft or ft /bdrm) System type a?, 100.,�� Length ftft, r" "^ Width 3 ft. Gravel below pipe 6 ft. Tao Vt tal depths 1101 t 'ft. Eff absorption area�� ft Monitoring tube Y Depression over field N 9%'30/16 Pass 3 ;`Date of adequacy test Results (Pass/Fail) For bedrooms <,\a 39.3 464 49.5 Fli id depth in absorptiodo n field before test in. Water added gal. New depth in. F Elapsed Time: 1;440,'min. Final fluid depth 39.3 in. Absorption rate >= 450 g p d Any rejuvenation treatment (past 12 mo.) (Y/N & type) N If yes, give date Septic Tank is more than 30 years old and nearing the end of its useful life. D. LIFT STATION Date installed _ "Pump on" level at Datum Size in gallons in. "Pump off' level at E. SEPARATION DISTANCES Cycles tested WELL ON LOT TO: Septic tank/lift station on lot > 100' Absorption field on lot >100' Public sewer main >75 Sewer /septic service line >25' Manhole/Access (Y/N) in. High water alarm level at Meets alarm & circuit requirements? On adjacent lots > 100' On adjacent lots > 100' Public sewer manhole/cleanout >100'. Holding tank >75 Animal containment areas >50 Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOTTO: Building foundation >5' Property line >5' Absorption field >5' 10, Water main > 1 Water service line > Surface water > Wells on adjacent lots > 100' ABSORPTION FIELD ON LOT TO: r Property line Building foundation >10 Water main >10 Water Service line >10' Surface water >1 00' Driveway, parking/vehicle storage > 10' Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION I certify that I have determined through field inspections and review of Municipal records that the above systems are in conformance with MOA COSA guidelines in effect on this date. Engineer's Printed Name Benjamin Schiller, P. E. Date to jet 11 1(r COSA brown sheet 10-10-12.doc rol P .....,t.....«. C .• r� ��p5lv,ww`bw ^h 8. V I 33' R.O.W. RESERVE BECKY LANE SEPTIC GRAVEL / 10.2'x18.0' PORCH 1 STORY RESIDENCE- / I - Lot 74, za.z SECTION 18 24.2' T15N, R1 W, GARAGE S.M., ALASKA 108,845.47 m°j I g0 Qty � 0 'IPES o PLOT PLAN AS BUILT X SCALE -11-= 60' GRID NW 1155 Project No. 16-319/A1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates inc. (907) 522-6476 Phone QooppO�O (907) 522-4625 Fax — p F Professional Land Surveyors kenolangsurvey.com AF'? ,. . q ��4 ., q p jonothonOlongsurvey.com �0.• .,S �O I hereby certify that I have surveyed the following described property: BLM LOT 74, SECTION 18, T15N, R1W, S.M., ALASKA Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the __"*111 Day of Dct•bPavn.. 2,6 tla at Anchorage, Alaska It Is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. 49TH . .... ..... A KEN ETH G. N 5202..' yJ4� p Oo 40naR.��SSIONAL _o CHAIN–LINK FENCE z 22.2 x 24.660 tT 0 p N ^ OV 11.8 n n V m 58.6' 31.7' z N 10S' WELL 114.0' 121.6'_........_ POWER POLES o PLOT PLAN AS BUILT X SCALE -11-= 60' GRID NW 1155 Project No. 16-319/A1 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates inc. (907) 522-6476 Phone QooppO�O (907) 522-4625 Fax — p F Professional Land Surveyors kenolangsurvey.com AF'? ,. . q ��4 ., q p jonothonOlongsurvey.com �0.• .,S �O I hereby certify that I have surveyed the following described property: BLM LOT 74, SECTION 18, T15N, R1W, S.M., ALASKA Anchorage Recording District, Alaska, and that the Improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that no Improvements on the property lying adjacent thereto encroach on the surveyed premises and that there are no roadways, transmission lines or other visible easements on said property except as indicated hereon. Dated this the __"*111 Day of Dct•bPavn.. 2,6 tla at Anchorage, Alaska It Is the responsibility of the owner to determine the existence of any easements, covenants, or restrictions which do not appear on the recorded subdivision plat. 49TH . .... ..... A KEN ETH G. N 5202..' yJ4� p Oo 40naR.��SSIONAL _o Ecklund, Timothy J From: Right of Way Requests Sent: Tuesday, October 18, 2016 11:02 AM To: Ecklund, Timothy J; Right of Way Requests Subject: ELM Lot 74, Section 15, ROW Encroachment into Becky Lane. Tim The MOA has not exercised our rights to use this BLM Easement; so we do not object to the stand pipe encroachment. Regards, Lynn McGee Senior Plan Reviewer Right of Way Section mcgeelm@muni.org 343-8226 343-8250 (fax) -----Original Message ----- From: Ecklund, Timothy J Sent: Tuesday, October 18, 2016 10:49 AM To: Right of Way Requests <MOAROWRequests@muni.org> Subject: Encroachment issues Good Morning, Do you folks have any issues with a stand pipe located in the 33' ROW Reserve located just West of where the driveway accesses Becky Lane? See attached As -built Thanks Tim -----Original Message ----- From: CDA002PRT Sent: Tuesday, October 18, 2016 11:04 AM To: Ecklund, Timothy J <EcklundTJ@ci.anchorage.ak.us> Subject: Scanned Document MUNICIPALITY OF ANCHORAGE MUNICIPALITY dF ANCHORAGE ~,~/.~:&:=:' '-- DEPARTMENT OF HEALTH & ENVIRONMENTAL PROTECTION DEPT, OF HEALTH &  825 L Street - A ~chorage, Ah~ska 99501 ENVIRONMENTAL PROTECTION W"O M TAL. V,S ON OCT 5 1978 Telephone 264-4720 REQUEST FOR APPROVAL OF INDIVIDUAl.. WATER AND SEW~I~ DIRECTIONS: Complete ail parts on page 1, Incomplete requests will not fie processed. Please allow ten (10} (Jays for processing, Charles Ferrin ~ 688-2690 Post Office Box 927 99577 ~.~ ...................... ~ ...... ...... PHONE Roberta ~oZb ~688-3114 Box 596 Sou~h B~=chwood %oep 99577 Stale of Alaska, Veteran's Adm&n~s~ratlon 274-7555 MAll. lNG ADDRESS 907 West Nor.~thern _Lights Boulevard 99503 4. REALTOR/AGENT Vir~iina Kohfzeld % Area Realtors 694-9555 MATIi~--~ ADDR ESS Post__~O_f_fice Box 249 99577 5. LEGAL DESCRIPTION T15N R1W Section 18 NE¼ of Lot 74 NUMBER OEBEDROOMS ~ SINGLE FAMILY I-L] One [2_-) Four [~-] Other [~iJ Two [--~ Five [O MULTIPLE FAMILY ~ Three [~] Six 7. WATER SUPPLY [--] COMMUNITY L-l_ PUBLIC UTI LITY 8. SI-'WAGE DISPOSAL SYSTEM * ATTACH WELt_ LOG, A well log is reqL red for all wells drilied since June 1975. For wells drilled prior to that date, give well depth (attach log if available.) INDIVIDUAL/ON-SITE** PUBLIC u'rl LITY If md v dual/on-s~te, g ye installation date 1978 If system is ovm two (2) years old an adequacy test is requiled by this Department, NOTE: THE INSPECTION FEE MUST ACCOMPANY EACN REQUEST BEFORE PROCESSING CAN BE INFI'IATEE), 72-0~ 0(3/78) THIS SIDE FOR OFFICIAL (JSE ONLY INSPECTION APPOIN'IMEN]% 1, "YPE OF RESIDENCE !~ SINGLE FAMILY :T} MULTIPLE FAMILY 2, WATER SUPPLY INDIVIDUAL 2: COMMUNITY PUl3 LIC UTI LITY Connection Verified L SEWAGE DISPOSAL SYSTEM : :IIN,r)IVIDUAL/ON SFFE ]]FUBL1G UTILFTY C;~mleC[~on Verified {~2}:eptJc Tank or IT] Holding Tank If Tank is homemade NUMBER OF BEDROOMS ~] ONE [2~ THREE [~ FIVE TJ OTHER LT~ TWO [~ FOUR [2~ SlX PERMIT NUMBER -6TP-~H OF WELL )ATE DRILLED tOG RECEIVED PERMtTNUMBER DATE INSTALl_ED INSTALLER SOILS RATING 4. I)IS"I ANCES , Septic/Holdhlg Tank lAbsorption Area lSewer Line ~st Eo~ Line WELL 'TO: [ ................. / I 5 ~:CMMENTS tL~/APPROVED FOR _,-.~ BEDROOMS CONDI]IONAL APPROVAL (letter must accompany certificate) DISAPPROVED ....... --~' ...... ] [~¢-2 Ti~[8~ ~ .................................... REALTORS REQUEST FOR APPROVAL OF INDIVIDUAL SEWER & WATER FACILITIES 1. Type of Inspection: CMRO VA_~ FHA CONV 2. Property Owner: ~./,/:: ~:' x~:: / c: Mailing Address: '_ ~?/,~ A/. ~".> ~.~' >~'i/Day Phone~ ?> "',, . .~. ....., ~ Day Phone ~;~- o Name of Lending Institution: ,,,~'(c. ~/, /:' : '' ' -- .":~ "'~ Phone Mailing Address: . Name of Realtor or Agent: .d:;'/~:/~/'~ ~ '~: Mailing Address: /'~-/:':/ .~"/~ Phone ~..: :~V ' .Y; ':< "~ Legal Description: -('¢ ~: Location: Type of Facility to be inspected: Water Supply Type of Supply: Public Utility ~ Individual If Individual, number of dwellings presently served If Individual, depth of well Sewage Disposal System Type of System: Public Utility ~ If Individual, date of installation: Individual (on-site) //,:~ REALTOR'~ AREA, INC. REALTORS [] Anchorage "C" St. Office 3300 C Street (907) ?7F~ 25?5 [] East Anchorage [] Eagle River Eastgate Office Parkgate Office 5437E. Northern Lights P.O. Box 249 (907) 278-2525 (907) 694-9555