On -Site Water & Wastewater System Permit
MUNICIPALITY OF ANCHORAGE
Development Services Department
On -Site Water & Wastewater Program
4700 Elmore Road, PO Box 196650
Anchorage, AK 99519-6650
Telephone: (907) 343-7904
Permit Number: OSP161354
Tax Code Number: 01509287000
Work Type: Welseptic Initial
Permit Effective Dates: December 16, 2016 to December 16, 2017
Design Engineer: ANDERSON ENGINEERING
Subdivision: MCCREADY MEADOWS
Site Legal Address: MCCREADY MEADOWS LT 9 G:2440
Owner/Address: MANNING MICHAEL
10560 SPINDRIFT LOOP ANCHORAGE AK 995152530
Site Mailing Address: 9800 CONIFER ST, Anchorage
This permit is for the construction of:
Y Disposal Field Y Septic Tank N Holding Tank
Lot Size in Sq Ft: 80542
Total Bedrooms: 4
N Privy Y Private Well N Water Storage
All construction must be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater
Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80).
3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services
Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either:
A. Open and Close on the same day.
B. Covered, sealed, and heated to prevent freezing.
Special Provisions: The entire subsurface disposal field (and alternate) is not within a 30 foot
radius of a percolation test. An additional percolation test is required prior to construction of
septic field, with stamped and signed results submitted with as -built inspection report. If the
results require a design change, construction of the system will stop pending On-site review and
approval.
Received
Issued By:
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904,-,
Development Services Division Fax: 907-343-7997 f
On -Site Water &Wastewater Program �^illy
ON-SITE SEWER/WELL PERMIT APPLICATION
Parcel I.D. 015-092-87
Property owner(s) Michael & Britta Manning Day phone
Mailing address 10560 Spindrift Lp, Anchorage, AK 99515
Site address 9800 Conifer St, Anchorage, AK 9507
Legal description (Sub'd., Block & Lot) McCready Meadows, Lot 9
Legal description (Township, Range & Section)
', DEC. 1 4 2015
Lot Size 80542
Sq. Ft.
Number of Bedrooms
4
APPLICATION IS FOR:
APPLICATION IS AN:
TYPE OF DWELLING:
(® all that apply)
Absorption Field
EE
Initial FXSingle
Family (SF)
❑X
(w/wo ADU)
Septic Tank
❑X
Upgrade ❑
Duplex (D)
❑
Holding Tank
❑
Renewal ❑
Multiple Dwellings
❑
Privy
❑
(SF and/or D)
Private Well
❑X
Water Storage
❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST
FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
rty owner or authorized agent)
Permit/Rush Fees: 614. 00
Date of Payment: 12 l i q /I &
Receipt Number: O0426!�
Permit No. u P 1(013roq
Permit App_:-' :'_.:c
Waiver Fees:
Date of Payment:
Receipt Number:
Waiver No
December 14, 2016
Municipality of Anchorage
Development Services Dept- On -Site Water & Wastewater Program
4700 Elmore Rd
Anchorage, AK 99507
Subject: McCready Meadows Sub, Lot 9
Septic system design and permit application
Dear On -Site Services Engineer:
The owner of the above lot intends to build a 4 -bedroom home on the property, so we are
submitting this permit application for the construction of a new well and septic system. The
attached site plan identifies the location of the home as well as the proposed well, septic location
and alternate site. No conflicts exist between this proposed system and any wells, whether on this
lot or adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction
of flow. The drainage pattern in general will not be changed by the construction.
The test holes placed on the lot indicate grey silty gravel. No groundwater or bedrock was found
down to 16'. The percolation rate was determined to be around 16 min/in. An application rate of
0.6 gpd/sf was used in the design of the absorption system. We are proposing to place a new
1250 -gallon septic tank with a deep absorption trench 3' wide x 63' long x 8' effective depth.
The elevation of the distribution line will be 2' below the surface for a total depth of 10'. Soil
will be mounded 0.5' above the trench. A minimum of 2" of insulation and 2' of fill will be
placed over the absorption trench and 4' over the septic tank.
The ground surface on the lot slopes steeply in the back, just past the area of the T&E easement,
but there aren't such steep slopes on any other portion of the lot. The ground peaks slightly south
of the house and starts to slope back toward the front, and where the house is it slopes down at
close to 20-22%. While there are slopes of 10-15% at places in the front yard, much of the front
is relatively flat, sloping up and back down a bit on the southern side. It is in that flatter area that
the new septic system is located. The new trench will be constructed parallel to the slope as
much as possible. It will be a minimum of 100' from all wells and surface water, and more than
5' away from the septic tank. The alternate site is located more than 20' away.
If the system is constructed as designed, it will have no adverse impact:
• On the wells in the area or those to be constructed in the future.
• On existing septic systems in the area or those to be constructed in the future.
• On reserve space, either surface or subsurface, on any lots located in the area.
• On drainage patterns in the area. The current drainage pattern will be maintained.
Sincerely,
31��PL-
BenjamiMehiller, PE
WILDWOOD GLEN SUBDIVISION
100' WELL RADIUS \
LOT 4 LOT 6 j \
PROPOSED WATER LINE ' f�-100' WELL RADIUS
j
MAINTAIN 10' SEPARATION FROM / I
ALL PARTS OF SEPTIC SYSTEM
TOP OF STEEP I (PROPOSED WELL
SLOPE 45,0
j (APPROXIMATE)
N 89'48'39"E 491.47'
10' T. & E. ESMT. --- 1— TH16 — ---- --- ------222_5-C 30.21'
—----
15%
o 120%
w i� INSUL
ATE UNDER DRIVEWAY Io
M McCREADY MEADOWS SUBDIVISION 200 M 0It
10' T. & E. ESMT—.—
F
LOT 9 �0% j 1 Fco / 107/ j w w
I PROP
I stjSEDDING
Co l Z v
z 50% 22% �i / ALTERNATE SITE j
/ I I
20%
I \ TH 15 I
I 8% I
i
i 34.21•:.............
S 89.58'49•'E 490.87' } - 10%
McCREADY MEADOWS SUBDIVISION \1�
100' WELL RADIUS ii
LOT 10A OF Fj
\�>>�
fZ. . .............
Be a Schiller
0 50 100 ` 1I+,"^'•, A L12592 .•�`�%
FEET CEJ, D.162016 ••G�r
MCCREADY MEADOWS SUB LOT 9
DESIGN FACTORS:
600 GPD PEAK FLOW
PERK RATE: 16 MIN/IN
APPLICATION RATE: 0.6 GPD/SF
SYSTEM REQUIREMENTS:
T WIDE DEEP TRENCH SYSTEM
1250 -GAL SEPTIC TANK
600 GPD / 0.6 GPD/SF / 8.0' DEEP / 2 SIDES = 62.5 LF Trench Length
THEREFORE: CONSTRUCT AN ABSORPTION TRENCH 63' LONG x T WIDE x 8.0' EFFECTIVE
DEPTH. FLOW LINE ELEVATION IN TRENCHES TO BE 2' BELOW ORIGINAL GROUND SURFACE.
TOTAL DEPTH TO BE 10' BELOW EXISTING GROUND. PROVIDE INSULATION AND 2' COVER
OVER ABSORPTION TRENCHES AND 4' OF COVER OVER SEPTIC TANK.
TO GROUNUVVA i LK
6' TO BEDROCK OR IMPERMEABLE LAYER
JLATION
'ERFORATED PVC (HOLES DOWN)
UNFIELD ROCK
TYPICAL DEEP TRENCH SECTION
Of At,-' l
(NO SCALE) fgP •'
NOTES: *• `STM - :*
GRADE AREA OVER TRENCH TO DRAIN AWAY / ..,
MIN 6' SEPARATION FROM BEDROCK/ Be a in Schiller
MIN 4' SEPARATION FROM GROUNDWATER �,PFc'•, A 1-12592
MIN 100' SEPARATION FROM NEARBY WELLS ,�(�E�PROFESSIONP r�
MIN 100' SEPARATION FROM SURFACE WATER OR STREAMS
PANNONE ENGINEERING SEMCE3
P.O. SOX 102954
ANCHORADS,AK99510
(907) 272.8218
PERFORMED FOR: Waan MoMvA4 DATE PERFORMED: 91-00
LEGAL DESCRIPTION, Let 9 M6Cceady 8/D
785T HOLE la
8IAd8 - lyf& .
a
4
a
6
7
e
g•
10.
11-
12-
is-
24-
15-
16-
17-
ie
2-
18-
14-
15-
16-
17-
18 -
is -
G0 -
4L
81
0
ri
P001VGnIdW
N89 521 t
TM14ua-:07 - —
aRAvscp/sneQEUIC
op
op oobbleaOboldom
785TH
I
...
N:1N
-A0
1. i
;H;5�
r (O
I C1 C"8 S
49T;'s66
_
r N
TO
OR�i1V6
. �' .w/cobble
Ir) Lo
:�
acres
WAS GROUND WATAR
B4OPe
ENCOUNTERED?
No
Ur AT WHAT
F—
�H Dg?
-0,
784f H018
DEPTH TO WATAR
AF58R
MONITORUfG?
DATE:
g{yO�
(F
RBADa/a i DA74. i I
t `
! 567 i DWM of
1opoee
T111F WAtPd nrta
i
g -:-r' poi:
C E iiE
�I
PEROLATION RATS l6 j'4L4
II
I
V PARC HQjA DIAMF'l+r>? 6 iAOye I
TEST RUN
8EW7VE - 617 End 7
PJ
maze we MmwM&Mw7mw
PANNONE ENGINEERING SERVICES
P.O. BOX 102954
ANCHORAGE, A$ 99510
(907) 2726219
PERFORMED FOR: eu6ea MoCre&4 DA79 PERFORMICD 9 1-04
LEGAL DESCHMONo L.ot 9 MoCreedy S/p
TIi6T H01M 16
aft
Olt ofmlxi�
1Tbpow
4
6°P
4
6
6
7
e
9T
10
11
12
19
14
16
16
17
is
19 -
40 -
son
��
I I 111 1
WAS GROUND WATER
E HOOUMMM? No
IF YES. AT WHAT
DEPTH? -0'
DEPTH TO WATER AFTER
MONI7+ORING?
DATE: g g 04
1 -? e-
i-49Lt1
lSte any'
�}et� No. CE 8149
i
TE6? HOLM
12ADIM6 1 DAR i
I �r I
MWM m !
xcr I
THI.::D�(11C
r;
WATIM
ow
,..
I
1}11
i �76:, ac, es .
n
i
TE6? HOLM
12ADIM6 1 DAR i
I �r I
MWM m !
xcr I
., uff
TIM
WATIM
ow
5'
('
i
i I
i/P'; i
PEROIATLON RATE 1_6199RtincM PFRC HOLE D1AMgM 61ncEa
i
TEST RUN BEWMEN 1 Fi ehd 6 F 1
•
• GC $`
''t _ Municipality of Anchorage °r
On-Site Water and Wastewater Program •.'a i.
(907) 343-7904 SAFETY
Certificate of On-Site Systems Approval
Parcel I.D. 015-092-87 ii
Expiration Date: r -21 -
1. GENERAL INFORMATION
Complete legal description McCready Meadows, Lot 9
Location (site address) 9800 Conifer St
Current Property owner(s) Michael & Britta Manning Day phone
Mailing address 10560 Spindrift Lp
Real Estate Agent Harding Homes of Alaska Day phone 337-9109
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
ill Duplex c' d`.
•
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4 J
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 0 Individual 0
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: _ 4-- 714
Date: 3/ 1 / I Y
COSA to be released t e engineer,unless otherwise requested by the engineer.
1 -51/1
COSA Fee $ \42- t 1 1 - l��. �b Waiver Fee $
Date of Payment 12-k I t. Date of Payment
Receipt Number 6181 4 t Receipt Number
COSA# OSC \ IZ 1 -1 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Forge Engineering Phone 577-7773
Address PO Box 240773, Anchorage, AK 99524
Engineer's Printed Name Benjamin Schiller, PE Date 3/16/18
_4 l
14
i*' )" * A
6. DSD SIGNATURE ` % l• •�+� �r..�
System #1 Approved for (( bedrooms 4 B �� f���
Y pp � '. Benjami�Chiller 592 •,.��
System #2 Approved for bedrooms ��ti%)..::. ,-j.�11•8. �'
Disapproved
4kV."PROFES5T +
Conditional approval for bedrooms, with the following stipulations:
\G�0,�.�T.�Op4j0
J� ,SO
- y�o °E-RsirF
CS PROEV GRAM R C3
,v/'Sr tiViC,F-
9 i
B . w.._- k-----x- � Original Certificate Date: 2, I i
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory /°C
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet r c
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Certificate of On-Site Systems Approval Checklist
Legal Description: McCready Meadows, Lot 9 Parcel ID: 015-092-87
A. WELL DATA
Well type Private If A. B, or C provide PWSID# Well Log (Y/N) Y
Date completed 8/1/17 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y
Total depth 205 ft. Cased to 204 ft. Casing height (above ground) >24 in.
FROM WELL LOG AT INSPECTION
Date of test 6/1/17
Static water level 140 ft. ft.
Well production 15 g.p.m. g.p.m.
WATER SAMPLE RESULTS:
Coliform Neg colonies/100 mL Nitrate 11 .0 mg/L
Arsenic ND ug/L Date of sample: 3/7/1 8 Collected by: Forge Eng
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 10/5/17
Tank size 1 250 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping Pumper New construction
C. ABSORPTION FIELD DATA
Date installed 10/5/17 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.6 System type Trench
Length 65.0 ftWidth 3.0 ft. Gravel below pipe 8.0 ft.
Total depth 13.9 ft. Eff. absorption area Monitoring tube Y Depression over field N
New constr
Date of adequacy test Results (Pass/Fail) For bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off' level at in. High water alarm level at in.
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100' On adjacent lots >100'
Absorption field on lot
>100'100' On adjacent lots >100'
Public sewer main >75' Public sewer manhole/cleanout >100'
Sewer/septic service line >25' Holding tank >75'
Animal containment areas >50' Manure/animal excrete storage areas >100'
SEPTIC/HOLDING TANK ON LOT TO:
>1 0' >5' >5'
Building foundation Property line Absorption field
Water main
>10'10' Water service line >10'10' Surface water >100'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line
>10'10' Building foundation >10' Water main >10'
Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >10'
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS
G. ENGINEER'S CERTIFICATION y���" ��\�
I certify that I have determined through field inspections and i Q~v . '
- V4,
review of Municipal records that the above systems are in 4
conformance with MOA COSA guidelines in effect on this date. /••• • ••
Engineers Printed Name
Benjamin Schiller, PE ,.., .!
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT • , � 907-343-7904
1 Fax: 343-7997
On-Site Water and Wastewater Section \
www.muni.org/onsite
Nitrate Advisory
Certificate of On-Site Systems Approval # 0SC181097
Subdivision: McCready Meadows, Block: , Lot: 9
A water sample revealed a nitrate concentration of 11.0 milligrams per liter (mg/L).
The Environmental Protection Agency (EPA) has established a maximum
contaminant level (MCL) of 10.0 mg/L for public drinking water systems. While
private wells are not subject to this regulation, EPA standards are based on existing
health information and can therefore be used to gauge the relative quality of water
from private wells. Please see the attached "Nitrate Fact Sheet" for important
information regarding nitrate.
This advisory must be attached to all copies of the subject Certificate of On-Site
Systems Approval.
Mailing Address:P.0.Box 196650*Anchorage,Alaska 99519-6650 *www.muni.org
Nitrate Fact Sheet
From Northern Testing Laboratories, Inc.
Nitrate is a negatively charged compound of nitrogen and oxygen,which is very soluble in water. Nitrate
is not readily filtered or otherwise removed in the soil and can pass rapidly into ground water wells.
SOURCE: Nitrate is a major component of fertilizer and wastewater. Often the nitrate is in the form of
ammonia or protein first, which through contact with oxygen and certain bacteria, converts to the
oxidized form known as nitrate. Sources of nitrate from wastewater include urea, ammonia cleaners,
food solids,and bacterial cells. It may also result from the breakdown of organic matter buried in the soil.
TOXICITY: Nitrate is generally not toxic to adults or children over the age of two or three years, but is
associated with a potentially fatal infant disease called methemoglobinemia. In the digestive system of
young children, nitrate converts to nitrite, which can pass through the intestinal wall into the blood
stream. There it combines with the hemoglobin and interferes with the ability of the blood to carry
oxygen. For this reason, methemoglobinemia is referred to as "blue baby" disease. The EPA limits the
concentration of nitrate in public drinking water supplies to 10 mg/L. The standard has been lowered
from a previous level of 45 mg/L set by the US Public Health Service and the World Health Organization.
TREATMENT: due to its solubility in water and negative ionic charge, filtration and other common home
water treatment systems such as softening or iron filtration does not readily remove nitrate. The best
method for limiting nitrate in well water is source control. This can include avoiding overdosing of
fertilizer near the well and maintaining good separation distances between septic tank leach fields and
the well. A special anion exchange filter that contains a media with a strong affinity for negatively charged
ions in water, or by a reverse osmosis treatment system or distillation can remove nitrate.
TESTING: Nitrate analysis is usually done by one of the several "wet chemical" methods using a
spectrophotometer to read the final color endpoint. Specific ion electrodes also can be used to detect
the activity of nitrate in water. This laboratory uses several different wet chemical methods approved
under the public water supply laboratory certification program. They also have test kits available, which
the laboratory uses to perform an inexpensive "screening test", and with which the homeowner can
monitor the change in nitrate levels from their well. They recommend comparing the test kit results
against a certified analysis from the lab occasionally to verify the accuracy of the kit. We recommend
using a specially prepared bottle that has been rinsed in hydrochloric acid for collecting samples.
Mailing Address: P.O.Box 196650*Anchorage,Alaska 99519-6650 *www.muni.org
McCREADY MEADOWSLOT9 SUBDIVISION
1.849 ACRES
N 89.48'39"E 491.47'
10'T.&E. ESMT. 221.4' 30.21'
r r tKu
I n! GRAVEL ORM ` 8
I I `
I -
g I
IT
n tai
i a! I e�oac rtcu New x+t�
• 10'T.do E.ESMT.�
4.la
N
'' I I TA, I
$ ar
• i is8
Z
I , 111111111
I I • I
I / I • 30.21'
•1 "=50' S 89'58'49'E 490.87'
1,114
;8
Ac'
...ti
4 p
N4 =0.
4.0.
44CCVEre
b
g
At& AS—B U I L T I HEREBY CERTIFY THAT I HAVE SURVEYED THE
PROPERTY DEPICTED ABOVE AND NAT NO .01.114 f
GASTALDI LAND ENCROACHMENTS EXIST EXCEPT AS INDICATED. S�
SURVEYING, LLC IT IS THE RESPONSIBIU Y OF THE OWNER TO �••P�•OF'•4, /.
JEFF A.GASTALDI, R.L.S. DETERMINE THE EXISTENCE OF ANY EASEMENTS, 'sr • •
2000E DOWUNG RD.,SUITE 8 COVENANTS OR RESTRICTIONS WHICH DO NOT y.•49IH ••'..9 ;
ANCHORAGE,ALASKA 99507 APPEAR ON THE RECORDED SUBDMSION PLAT. I' ....'...
BUILDING DETAIL PHONE 248-5454 UNDER NO CIRCUMSTANCES SHOULD ANY DATA '
HEREON BE USED FOR CONSTRUCTION OR FOR 1,..•••'1eMei. a aai17•
GRID DATE ^ � lS-6o9t e>°4•
SCALE: 1"="20' ESTABUSHING BOUNDARY OR FENCE UNES. . �.. ... o('II/!.'y3'*
SW2440 10/31/2017 a .
F.B. JOB NO. ANCHORAGE RECORDING DISTRICT,ALASKA 1...�,"a' *'
17-04 MCM9 NOTE: NO CORNERS SET THIS DATE