HomeMy WebLinkAboutRISU TOMAX TR BONSITE FILE R'isu Tomax #051-151-30 On -Site Wastewater Disposal System Permit MUNICIPALITY OF ANCHORAGE Development Services Department On -Site Water & Wastewater Program 4700 Elmore Road, PO Box 196650 Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP161329 Tax Code Number: 05115130000 Work Type: Septic Initial Permit Effective Dates: December 16, 2016 to December 16, 2017 Design Engineer: RODNEY P KINNEY ASSOC INC Subdivision: RISU TOMAX Site Legal Address: RISU TOMAX TR B G:1257 Owner/Address: MCKINLEY THOMAS K & MAXINE 20328 CRABTREE STREET CHUGIAK AK 995675917 Site Mailing Address: 20328 CRABTREE ST, Chugiak This permit is for the construction of: Lot Size in Sq Ft: Total Bedrooms: G0t._ S<< l)epartmenr 32292 3 Y Disposal Field Y Septic Tank N Holding Tank N Privy N Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either: A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing. Special Provisions: An additional test hole is required near (no closer than 5 feet) the south end of proposed field prior to installation to confirm separation to groundwater and impermeable barrier. Please submit stamped and signed results with the as -built inspection report. If the results require a design change, construction of the system will stop pending on-site review and approval. ':R/31/11 CA l l : Rte, i se �r ern c is n Received By: Issued By: .Date: Date: (2 1 l0 02 0 /6 Municipaflty ®f Anchorage P.O. Box 196650 0 4700 Elmore Road Anchorage Alaska 99519-6650 0 (907) 343-7904 0 Fax (907) 343-7997 http://www.mun i.org/Onsite Development Services Division On -Site Water and Wastewater Program **** VARIANCE/WAIVER REVIEW **** Waiver#: OSV161154 COSA#: _ Permit#: OSP161329 PID#:051-151-30 Legal Description: Risu-Tomax Tract B Engineer: Rodney P. Kinnev, Jr., P.E. Applicant: Laura Hettmansperger Your request for a waiver of the required 10 feet separation between the proposed absorption field and the existing absorption field has been approved. The approved separation distance is 0.0 feet. See engineer's letter for waiver requests. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. ❑ The affected adjacent property owner(s) have been given a 7 day notice regarding this waiver. ❑ Notarized letter(s) of nonobjection have been received from the owner(s) of the affected adjacent property. ® Adjacent properties are not affected by this waiver. ............................................. Waiver is Granted: X Waiver is not Granted: Date: 1a /16' 6 ao 16 Approved by: " & to U ................................................Name ... of ...................... **** VARIANCE/WAIVER REVIEW **** MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. a S 1- 15 1- 30 / ,�' � /l �jYlOH 9(�JKSCn>�Ve Propertyowner(s) k_ocura G7��YNar�sAe�4er�ts '�'Dayphone '7?0 Mailingaddress 9/5- SYKoKer,se &3 J. t?or-I OronS,2 fL Siteaddress 4o3ag Cv,0o t-ee (_avle Cit.sl'o,K iC 8956'7 Legal description (Sub'd., Block & Lot) P-150 - To"A71- SuT?rn, 7I0�&t T fS Legal description (Township, Range & Section) 715/�1 R- W S Ue- 8 Lot Size 3ZZ`1 Z Sq. Ft. APPLICATION IS FOR: (® all that apply) Absorption Field Septic Tank 19 Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage ❑ Number of Bedrooms APPLICATION IS AN THIS APPLICATION INCLUDES A rom Initial Upgrade ❑ Renewal ti ��(moV 0 7 2016 e�3 WAIVER TYPE OF DWELLING: Single Family (SF) (w/wo ADU) Duplex (D) ❑ Multiple Dwellings ❑ (SF and/or D) EST FOR: Distance: < 10 I certify that the above information is correct. I further certify that this is in accordance with applicgble Municipal Codes. of property owner or Permit/Rush Fees: $56 / O O Waiver Fees: a ISM Date of Payment: 11r— 7 '/ (o Date of Payment: 1 a / 1 b a o 1 (o Receipt Number: �3�� Receipt Number: a0' 5� Permit No. oS��6/�Z % Waiver No. CSV 1 b l 1 5 `i Permit App_:. :_'.A . MUNICIPALITY OF ANCHORAGE QD Community Development Department Phone: 907-343-7904 On -Site Water & Wastewater Program Fax: 907-343-7997 Septic System Owner -installer Agreement A real estate property owner (Owner) may install their own septic system. The department may issue an approval for a homeowner to perform work on a conventional (not AWWTS) on-site wastewater disposal system to serve that individual's owner -occupied, single-family or duplex home if the homeowner satisfies and agrees to the following requirements. The property owner and excavation equipment operator may perform work on no more than one owner installed project in a 12 -month period. As owner of (legal description) F 1Cr 1 Toy i.4x 7 -44 -at— Q I agree the following items are true and accurate. My experience installing septic systems is as follows. is Currrn-I-wij-h wl/ 07whterpa.lri-y'rr5rvirem4-trr- 2. The name of the excavation equipment operator is. %rP lli�i ✓lia,�-Iodc I 3. There will not be compensation for installation services rendered. 4. 1 will be actively involved with the septic system installation at all times. 5. The name of the inspecting engineer is IZ9 D V__IAw `7 6. 1 agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.150. c. 2 -hour minimum advance notice given to the On-site Water & Wastewater Program for all required municipal inspections. I agree any changes I make to the items listed above will require a new approval before performing work. 8. 1 agree to have the project -specific On-site Wastewater Disposal System Permit available at the construction site for the duration of all related work. Owner's printed name: ,/,0 -IL hdL M t �-jyt 2n SPGr� er Owner's signature: CZGI a- Date: o2D�6 Septic System Owner Installer Agreement_Feb2015.doc Rodney P Kinney Associates, inc. Consulting Engineers a surveyors November 07, 2016 Municipality of Anchorage Development Service Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, AK 99519-6650 Attention: Deb Wockenfuss Subject: RISU-TOMAX Subdivision, Tract B` New Septic System . Dear Mrs. Wockenfuss: The purpose of this submittal is to request your review and approval to construct the proposed on- site septic system. Attached are the following documents: 1. Scaled drawings with related details, 2. MOA handout for construction requirements, 3. Soils Log — Percolation Test form, 4. Stamped drainfield design calculations, 5. On-site Sewer Permit Applications The adjacent properties consist of single family homes with on-site water and sewer systems. No wells exist within 100 feet of the proposed absorption field. The adjacent properties should not be affected by the location of the proposed improvements in regards to wells, septic systems, reserved space, and drainage. The existing and proposed septic system is located outside of any travel ways. Please call (907) 694-2332 if you have any questions. Sincerely, RODNEY P. KINNEY ASSOCIATES, INC. Rodney P. Kinney, Jr., P.E Project Engineer Enclosures 16515 Centerflel0 Drive a suite 101 ■ Eagle River, Alaska ■ '99577 907.694.2332 1 Fax 997.694.1807 a www.roka.net Rodney P. Kinney Associates, inc. Consulting Engineers a surverors December 14, 2016 Municipality of Anchorage Development Service Department On -Site Water and Wastewater Program 4700 Elmore Road Anchorage, Alaska 99519 Attention: Rebecca M. Carroll Subject: RISU-TOMAX Subdivision, Tract B OSPI61329 Request for Separation Waiver Dear Ms. Carroll: 16 -CK -1794 Please reference our letter dated November 7, 2016 requesting review and approval to construct the proposed on-site sewer system and your email dated November 28, 2016 transmitting review comments. The purpose of this letter is to request a separation distance waiver for the proposed absorption field to be closer than 10 feet from the existing field. This project proposes to upgrade the existing septic system to bring it into compliance with current Municipal standards. The majority of the existing drain field is believed to be located within the 10 feet setback requirement as described below. 4 inch plastic pipe ends were exposed at two locations near the northern end of the proposed deep trench. These pipes are believed to be part of an existing drain field system positioned within the clean sandy gravels. The clean gravels appear to be backfilled around each of the pipes similar to the native gravels shown in the attached soils log from 1 foot to 4 feet. There was no evidence of a formal stone -filled trench or bed absorption system. Also, there was no evidence of odor, discoloration or staining of the soils near or below the exposed pipe indicating very minimal use or leachate application. The silty sand below the pipe did not appear to be disturbed. It is intended that the proposed deep trench be located in the native silty sand deposits well below where the existing field is believed to be located. The existing field will be disconnected and abandoned. The silty sand deposits appear to be in a natural state and are suitable to receive and treat the proposed effluent. We propose to complete additional excavation and verifications to satisfy any MOA concerns prior to installing the proposed drain field if necessary. 16515 Cenlerliela Drive in Suite 101 a Eagle River, Alaska - n 99577 907.694.2332 1 Fax 907.694.1807 1 www.r0ka.nel RISU-TOMAX Subdivision, Tract B OSPI61329 Request for Separation Waiver Page 2 of 2 We do not anticipate any impacts to adjacent properties, health hazards, nuisances, and effects to the surrounding properties or groundwater. Please call (907) 694-2332 if you have any questions. Sincerely, RODNEY P. KINNEY ASSOCIATES, INC. Rodney P. Kinney, Jr., P.E Project Engineer :rpk I I --- -----------� I MCKINLEY VIEW AVENUE INSTALL NEW ABSORPTION FIELD, SHED R'�w— TOMAX 1 % / SUBDI VISION 0_�BARN SEE FIGURE 2 TRACT R 370/ 3%I IG ��LL 1-7 0 1 HOUSE I� -- -------- I '\s% LOT 96 / W EXISTING \ / SEPTIC \ \ / TRACT A / 5% EXISTING NLd SEPTIC I 433% I' L---------- LIN \ SUBDIVISION 1 _ I EXISTING SEPTIC / I LOT 113 / HOUSE 1 HOUSE\1 I �0� I �� I I LOT 1 I LOT 2 I I � — T JAYHAWK DRIVE I LEGEND SANITARY SEWER CLEANOUT ST SEPTIC TANK CLEANOUT MT MONITORING TUBE —5— NEW SEWER LINE GRAPHIC SCALE o so too s— EXISTING SEWER LINE loo EXISTING WELL 1 inch — 100 feet ® TBM—BASEMENT FLOOR = 100' VEWAY SHED LOT 115 UNDEVELOPED OF t70 9TI �.............. � ...... ... .p '. Roy P. Kinney Jr..' a 0 &- CE7955 & A lkefo .. 11/29/16.•' �d� `,z )'I.ofessid'oo� Rodney P. KinneyAUoCoe¢es,inC. TRACT Be RISU—TOMAX SUBD. SITE PLAN Consulting Engineer, a smeevors PLAT 74-103, ANCHORAGE REC. DIST. 11/29/2016 FIGURE 1 I� -- -------- W Lu o LOT 94 NLd w� W N Z 1 C D w SEPTIC AND WELL CID N LOCATION UNKNOWN M waw U a l - o Z m Hou SE JOU 1 30 3 \ 1 Z \ LIN \ SUBDIVISION 1 _ I EXISTING SEPTIC / I LOT 113 / HOUSE 1 HOUSE\1 I �0� I �� I I LOT 1 I LOT 2 I I � — T JAYHAWK DRIVE I LEGEND SANITARY SEWER CLEANOUT ST SEPTIC TANK CLEANOUT MT MONITORING TUBE —5— NEW SEWER LINE GRAPHIC SCALE o so too s— EXISTING SEWER LINE loo EXISTING WELL 1 inch — 100 feet ® TBM—BASEMENT FLOOR = 100' VEWAY SHED LOT 115 UNDEVELOPED OF t70 9TI �.............. � ...... ... .p '. Roy P. Kinney Jr..' a 0 &- CE7955 & A lkefo .. 11/29/16.•' �d� `,z )'I.ofessid'oo� Rodney P. KinneyAUoCoe¢es,inC. TRACT Be RISU—TOMAX SUBD. SITE PLAN Consulting Engineer, a smeevors PLAT 74-103, ANCHORAGE REC. DIST. 11/29/2016 FIGURE 1 SWING TIE TABLE ® BLDG. COR. (D BLDG. COR. CO#2 CO#3 CO#4 CO#5 CO#6 CO#7 MT#1 MT#2 TO BE FILLED OUT AFTER CONSTRUCTION TRACT 6 1 DEEP TRENCH10' TYP.. SEE 5'lCO#6 MIN. FIGURE 3 1 I \ �I 1 CO#7 5' TEST - MT#2 PIT #1 I - •r � MT#1 I 1 10' 10' R=30'\\� _ 30.• I I h 4" PERFORATED 30"/i PVC j SEPTIC RESERVE ' AREA \ ST#1 ST#2 W W LLJ �\ EXISTING t000 GAL / LLI ASEPTIC TANK / � � m U - - COT- - EXISTING SEWER I ` i LINE ,OFgt.,% �:)1.4s / / MOBILE HOME — FOR STORAGE ONLY. , / DO fJ07 CONNECT TO �'�, • • • ^ � ' •' • ..... • .. . ON—SITE SEWER SYSTEM. {" P.1Cwwiv.Jr.or vcmm ---- --, pp. CANOPY l � � ..... ,/ GRAPHIC SCALE �p �F� ! Co "I 20 0 10 20 C 1 inch m 20 deet HOUSE 0-4 SEPTIC SYSTEM . inneyfiggCjgje�, iflL TRACT B, RISU-TOMAX SUED. LAYOUT C.cfIt1.1 E.9t... tz . salm.r. PLAT 74-103, ANCHORAGE REC. DIST. 8/31/17 FIGURE 2 a e CD CEW ee OR cm a D I co 0. (A ;a z N o c =I O� 0 O o K my ;u X m P N c o co N N A rn O m rn c A m w H: 1'=10' V: 1"=5' SEPTIC SYSTEM PROFILE 105 HOUSE 105 CO#1 EL 97.23' PLACE FILL OVER EXISTING TANK TO PROVIDE 4.1' MIN. BURIAL DEPTH 100 EL.=93.28' 100 EL.=95.11' EL.=94.81' CO#4&5 EXISTING EL.=93.16' GROUND MT#1&2 CO#6&7 95 95 EL.=97.48' II L.=92.70' II4" PERFORATED II 11 90 EXISTING PVC PIPE 0.0% II 90 1000 GALLON- EL=92.53' SEPTIC TANK EL.=89.16' DEEP TRENCH EL.=89.16' EL.=85.16' ' SEE CROSS SECTION, FIG. 4 �. II 85 85 8.0' EXISTING SEPTIC SYSTEM 10.0' 42.0' H: 1'=10' V: 1"=5' SURFACE MOUNDED TO INSURE DRAINAGE AWAY FROM DRAINFIE 3' EL.=89.66'- 6" GRAVEL NATIVE SOIL . BACKFILL i/moi/ice � a 0 EL.=85.16'— ° (MAX DEPTH) 30- I 30' I SEASONALLY HIGH STATIC CT FER FABRIC PERFORATED PIPE GRAVEL DEPTH BELOW PIPE (4') Z e DEEP TRENCH CROSS SECTION NTS 3 BDRM = 450 GPD SOILS — 0.6 GPD/SQ. FT. 450/0.6 = 750 SQ. FT. REQUIRED MAX GRAVEL DEPTH = 85.16' 3' MIN. DEPTH 4' EFFECTIVE 2.5' WIDE 94' TOTAL TRENCH LENGTH— 2) 42' = 84' 1)10 =10' 94' INSTALL SEPTIC SYSTEM IN ACCORDANCE WITH MOA WASTEWATER DISPOSAL CODE (AMC 15.65). OF.Aar ZA\\ � *I /j�j�� r....... p Rodne/P. Kinney I ��. �•. CE7955 q 00 aOt- 11/29/16. '��' AO %\rvP'ofessio,, e® DEEP TRENCH Rodney PNinneyAssociaies,inc. TRACT B, RISU—TOMAX SUBD. CROSS SECTION canaoltloo Enoloaara a anraaYor: PLAT 74-103, ANCHORAGE REC. DIST. 11/29/2016 FIGURE 4 Municipality of Anchorage Development Services Department Building Safety Division ® yam• On -Site Water and Wastewater Program 4700 Elmore Road P.O. Box 196650 Anchorage, AK 99507 www.ci.anchorace.ak us (907) 343-7904 Soils Log - Percolation Test Performed For: Laura Hettmansperger Legal Description: RISU-TOMAX Tract B t','rIaN-;i b 5 /w Date Performed: October 1.0, 2016 Township, Range, Section: T1 5N, R1 W. Sec. 8 nan c4e.Pt Irrk —1 Sar-'nA GP 6- S•l+� 5ard 8- w A), aPfavL� a- �J _ SM 1 11 13- (' 14 - god'-�-o 15- JL?o5 Pr URI 19 - WAS GROUND WATER ENCOUNTERED? Date Gross Time 5 IF YES, AT WHAT DEPTH? NVQ L AIA Depth to Water Aker 0 Monitoring? E NA E Date: '/-3—)6 Reading Date Gross Time Net Time Depth to Water Net Drop lo - 9 -It, Z'41 Pn — `i 30 .tn(,V 3 51 LA- I 1 P �^ y 5/I t - H',`11 Pmt 3'0 in (� 3 1te I Iti/G I.tn (minutes/inch) PERC HOLE DIAMETER 10" TEST RUN BETWEEN S FT AND FT PERFORMED BY: FORhLew 4-�` hrtLN I N CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE ITH ALL STA AND MUNICIPAL GUIDELINESAN EFFECT O THIS DATE. DATE: t O— IL, ((�