Loading...
HomeMy WebLinkAboutR MILLER LT 2DEPT. OF ENVIRONMENTAL, CONSERVATION DIVISION OF ENVIRONMENTAL HEALTH "FRANK H. MURKOWSKI, GOVERNOR 555 CORDOVA ANCHORAGE, AK 99501 Phone:(907)269-7519 Fax: (907) 269-7650 http://www.state.ak.us/dec/ DRINKING WATER AND WASTEWATER PROGRAM December 30, 2003 Jeffrey A. Garness, P.E. Alaska Water & Wastewater Consultants, Inc. 3701 E. Tudor Road, Suite 101 Anchorage, Alaska 99507 Re: Tract F & G, Lot 4, Fire Lake Subdivision, On-site Wastewater Treatment and Disposal ADEC Project # 2307 Dear Mr. Gamess: This is in response to the record drawings received in this office on November 25, 2003. The on- site wastewater system is serves a 5 bedroom duplex and a 3 bedroom separate home both located on lot 4. If Lot 4 is subdivided, you will need to provide an operational agreement to allow the wastewater system to continue to operate. A copy of the agreement must be provided to this office, showing how the owners of the subdivided parts of lot 4 will continue to properly operate the advantex wastewater system serving both the duplex and the single family home. I have reviewed the engineering drawings which detail the use of a 3,500 gallon Septic Tank Effluent Pumping (S.T.E.P.) tank, with a two AX -20 Advantex pods, and a soil absorption consisting of two 30 feet long 5 feet wide sand lined trenched which are noted on the record drawing to be over 4 feet above the localized groundwater and over 6 feet above bedrock or impermeable soil. From the information submitted it appears that the wastewater disposal system has been designed and constructed in accordance with State Wastewater Disposal Regulations. Therefore, in accordance with the State Wastewater Disposal Regulations (18 AAC 72.225), final operational approval for the system is issued. This approval does not imply the granting of additional authorizations nor obligate any state, federal or local regulatory body to grant required authorizations. Any person who disagrees with this decision may request an adjudicatory hearing in accordance with 18 AAC 15.195- 18 AAC 15.340 or an informal review by the Division Director in accordance with 18 AAC 15.185. Informal review requests must be delivered to the Division Director, 555 Cordova St., Anchorage, Alaska 99501, within 15 days of the permit decision. Adjudicatory hearings requests must be delivered to the Commissioner of the Department of Environmental Conservation, 410 Wiloughby Avenue, Suite 303, Juneau, Alaska 99801, within 30 days of the perm t decision. If a hearing is not requested within 30 days , the right to appeal is waived. Thank you for your cooperation. If you have any question please do not hesitate to contact me at 269-7519. Respectfully, William R. Rieth, P.E. W RR Environmental Engineer Enclosure: As stated cc: David Johnson, DW/WW, w/o enc. STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION CONSTRUCTION AND OPERATION CERTIFICATE FOR DOMESTIC WASTEWATER DISPOSAL SYSTEMS A. APPROVAL TO CONSTRUCT Plans for the construction or modification of ZV 7, located in by domestic wastewater disposal system Alaska, submitted in accordance with 18 AAC 72.210 have been reviewed and are approved. conditionally ap o d (see attached conditions): UY /� Z TITLE DATE If construction has not started within two years of the approval date, this certificate is void and new plans and specifications must be submitted for review and approval before construction. B. APPROVED CHANGE ORDERS Change (contract order number or descriptive reference) Approved by Date C. APPROVAL TO OPERATE The "APPROVAL TO OPERATE" section must be completed and signed by the Department before this system is made available for use. The construction of the 3SGI�g� l i �� Ax 20'�omesti ast��ter disposal system was completed On. date). The system is hereby granted interim approval to operate for 90 days following the completion date. TITLE DATE As-built/record drawings, submitted to the Department, or an inspection by the Department, has confirmed that the domestic wastewater disposal system was constructed in substantial conformance with the approved plans. The system is hereby granted final approval to operate. BY �i!/Lp /Ury71L��LR/�L.ILG�rj D—e.(i� J�GCiI� TITLE �'-- DATE - -- Distribution I. Retain original for project file 2. Make copies far distribution Mat tF� 7a, 6 i( c o'+ t1/lq/63 ALASKA WATER & WAS'TEWA'TER CONSULTANTS, INC. November 19, 2003 State of Alaska Department of Environmental Conservation Division of Environmental Health Drinking Water & Wastewater Program 555 Cordova Street Anchorage, Alaska 99501 Subject: Approval to Operate for Tract G & F, Lot 4; Fire Lake Subdivision (ADEC Project Number 2307) To whom it may concern: The septic system upgrade for the referenced property was installed between August and October of 2002. We have been trying to have the owner's statement signed by the new owner. During construction, the property was an estate property that was being purchased by the current owner Everett Jay. Several attempts were made to have the new owner sign the owner's statement, but he has not returned a signed statement. Please contact Mr. Jay directly to have him sign the owner's statement. The last phone numbers we had for him was 332-1690 or 242-1690. During construction, verbal approval was obtained from Keven Kleweno to connect both the duplex located on Tract F, Lot 4 and the single family residence located on Tract G, Lot 4. Also, per our phone conversation with Mr. Klewenc, it was verbally approved for the septic system to be sized for a total of 8 bedrooms. We request that an "Approval to Operate" be issued for the septic system on the referenced property. If you h+e any further questions, please call us at 337-6179. P.E., M.S. 3701 E. Tudor Road, Suite 101 * Anchorage, AK 99507 Ph: (907) 337-6179 * Fax: (907) 335.3246 * 'Website: akwwc.com Fore: 1. 7hit serfion should be signed by e Certified Lutdleq Profusionaf Engineer. DECsra� or tTvnerBvilder 2. AI! public water system must receive ADEC plan approval prior to construction. See 18 AAC 80 State afAlasta Drinking Water Regulations for spec f c requirements Date Received STATE OF ALASKA DEPARTMENT OF ENVIRONMENTAL CONSERVATION DOCUMENTATION OF CONSTRUCTION Legal Description of the Location Submitted. by: FIRE LAKE SUBDIVISION; LOT 4, TRACT F ❑ Certified Installer In Approved Homeowner Registered Engineer Installer Name: Onsite Wastewater System Serves: ALASKA WATER & WASTEWATER CONSULTANTS ® Single Family. Number of Bedrooms *3 Mailing Address ® Duplex. NtunberofBedrooms . *5 3701 E TUDOR ROAD, SUITE 101 ❑ Small Commercial Facility With Estimated ANCHORAGE, AK 99507 Design Flow of less than 500 GPD. II.- WATER SUPPLY SYSTEM (SECTION E IS OPTIONAL) of Water and Containment (Check all that Apply) Type of Water Supply System Treatment of Water (Check all that Apply) ❑ We 7ledar Driven) ❑ Surface(/dentify) ❑ Roof Catc ❑ Holding Tank ❑ Other(rdemtfy) ❑ SF/Duplex ❑ Public ❑ None ❑ Chlorination ❑ Filtration ❑ brinera]Re a ❑ Other. Well Dam Is the Inughl of the well cas ' ore than 12" above theground? es ❑ No Is a sanitary seal or well cap installed o well casing? ❑ Yes ❑ No Is drairectic directed away from or around the casin thin a radius of 10 feet of the well casin ❑ Yes ❑ No Is well wires enclosed in coodui@ ❑ Yes ❑ No Date Intl ed Depth of Well (Feet) Stafic We ev eat) Yield QfavailableJ Pump Rate (Ijmnifable) Separation Distance from the We Casing to each of the Following ours o on anon SepnrlHoldmg Tallon Lot Sewer hoes t Absorimon Area on Lot Feet -t Closest Septic/Holding Tank onAdjacent Lot sesi Sewer Lines onAdjacent Lot Feet est Edge of an Absorption Aren on et Fee, Adjace t Feel Indicate separation distance from toxic material' ding fuel tanks, paints, lubricants and other petroleum based materials, pesticides, fun ' es or herbicides to well Gazing: Water Samples Taken by: e) On Lot On Adjacent Lot Feel Sampler is: ❑ Buyer ❑ Engin Address ❑ Banker ❑ Government O ic' Wate ple Results: It Co v ❑ Satisfactory- Date ❑ Unsatisfrcto � - Date Comm entsiRecommendations: *RECEIVED VERBAL APPROVAL FROM KEVEN KLEWENO TO CONNECT BOTH THE DUPLEX AND THE SINGLE FAMILY RESIDENCE TO THE NEW SEPTIC SYSTEM. ALSO VERBAL APPROVAL WAS OBTAINED TO SIZE THE SEPTIC SYSTEM FOR A TOTAL OF 8 BEDROOMS. I certifv that the above inled in SectionV.'s correct - Signature TYped/Printed NameTitle Date JEFFREY A. GARNESS, P.E. PROFESSIONAL ENGINEER Fore: 1. 7hit serfion should be signed by e Certified Lutdleq Profusionaf Engineer. DECsra� or tTvnerBvilder 2. AI! public water system must receive ADEC plan approval prior to construction. See 18 AAC 80 State afAlasta Drinking Water Regulations for spec f c requirements f 9 9 I,.,. ,V.y��Lw.yttxulsrtugL Legal Description: FIRE LAKE SUBDIVISION: LOT a_ TaecT 7 ❑ Septic Tank with Conventional Soil Absorption System M Package Treatment Plant (requires engineered design) 12 Holding Tank: Material Type: Size in Gallons; Manufacturer: ❑ Other - Specify Type: ❑ Alternate Onsite (requires engineered design) ❑ Small Commercial System (<500 GPD) With Estimated Daily Wastewater Flow of: Gallons Per Day (GPD) Criteria Used to Estimate Daily Wastewater Quantity: ® NEW SYSTEM ❑ REPAIR TO EXISTING SYSTEM Certified Installer Installation Notification Date: Name ofinstaller: CCC CONSTRUCTION Date Installed: g 15 02-10 5 2002 System Installed: ❑ By a Registered Engineer M With Inspection by a Registered Engineer ❑ By Approved Homeowner (attach copy of approval letter) ❑ By a Certified Installer/Installer Number Septic Tank: Material: Manufacturer; Size (Gallons): Number of Compartments: STEEL S.T.E.P. ANCHORAGE TANK 3500 2 Type of Soil Absorption System: ❑ Deep Trench M Shallow Trench ❑ Seepage Pit ❑ Bed 177 Mnnn/i w n,te_ c___:c. .......... ___. _. __. _ rUVAIMMA IKLAIMLNI SYSTEM Soil Classification: SM ML Soil Rating: 4.0 GPD SO.FT. Dimensions/Sim of Absorption Area: 2 ® 30' LONG x 5' WIDE Grading/Size of Distribution Rock: 3Z4" TO 2-1/2" Thickness/Depth of Distribution Rock: 0.5' Percolation Test Results, Attach Copy of Report: Percolation Test Performed by: <1 & 2 MinutesperInch N/A Sq. fl. erbedroom JEFFERY A GARNESS, P.E. P percolation test results m,ui 6e sealed/signed by o registered engineer, List ground cover in feet over: Septic Tank: 4'+ Absorption Area: *3'+ Sewer Pipes: 4'+ Cleanout Pipes/Caps Installed: Foundation Cleanout YES Septic Tank: YES Monitor Tubes: YES Indicate semamtion di tance� from septic tank or absorption area, whichever is closest to, to all nearby: Public drinking water sources within 200 feet: 200'+ Private drinking water sources within 100 feet: 100'+ Nearest water bodies (see 18 AAC 72.020(6)): 100'+ Lot Line: 10'+ Separation Distance from Onlot Sewer Lines to: Public Drinking Water Sources: 1001+ Private Sources: 25'+ Separation Distance from Bottom of Distribution Rock to: Groundwater Table: 4'+ Bedrock: 6'+ Separation Distance from Absorption Area to Slope exceeding 25%: 50'+ *THE DRAINFIELDS AND ALL SEWER LINES WERE INSULATED. I SEAL Regurered Profrssional Engineer I Ile, Keg./Cert No., IWL No. - Date JEFFREY A. GARNESS, P.E. I PROFESSIONAL ENGINEER PloflEg • DEC v f, or Approved Homeowner. /fengmeenng seal bears printed name, 9 '7. .. .............. re mess ly. ' E 7953 oG Oso e•'' .•'�Oc op p� �P........\ o 4t\�_rp fesslet,. o / .UPPER FIRE LAKE./ NOTE: SEPTIC SYSTEM WAS SIZED FOR A 8 BEDROOM SYSTEM. S - L LINE UNDER DRIVEWAY — WAS INSULATED WITH 4" OF BLUEBOARD- SMALL STREAM tom/ .�, •�'�' s� 4,1(APPROX. LOCATION) � j EXISTINGWELLS G r j I I may{ .•:: a. '. SLAC{( \ I NEW 3500 GALLON ADVANE I '10D FEET E WATER TREATMENT SYSTEM WITH DUAL Tp SURF TM#� I I PODS AND PUMP VAULT. I j / NEW DPMNFIELDS / ' INSTALLED DOUBLE I MH2 / CLEANOLUS / II #TH#4 I I MT, MU II o � ill �'-- �+ I I MT2 j j A B r MT4 /•i a - iRAC1c G, \ T 3; ' N FIRE LAKE S/D EXISTING ( \ WE L I I 1 I FGIXISTING .. I 300USEOM � �c4' ;', EXISTING t I s CULVERT ST1 114.25 112.90 MH1 126.60 125.59 MH2 128.60 125.50 MT1 164.05 156.51 MT2 184.48 176.33 MT3 164.22 154.47 MT4 190.94 180.76 - DATE: 1/19/2003 F x. .....y DRAWN BY: ALASKANNATER & NvASTEAN'ATER C.J.G./J.L.M. CONSULTANTS, INC. SCALE: 3701 E TUDOR ROAD, SUITE 101 • ANCHORAGE. AK 99507 • PHONE 007)337-6179 • PAX (907)338-3246 1 ,— 50 3 _ I PREPARED FOR: ESTATE OF LILLIAN STEVENS PHDNE NUMBER: PAGE NUMBER: 1 C/o JOE PEROZZI w/ REMAX OF E.R. 694-4200 1 OF 2 "" ++" '"'1"' '•.Jef rey? A. Ga ess� s7 LEGAL DESCRIPTION: - V A O TRACT F, LO7 4,; FIRE LAKE SUBDIVISION �o4s - C 11953 p t ceO TMP ASF BUILT OF SEPTIC UPGRADE (ADVANTF)( 4YSTFMI 4�pp °f@set°^Oo�