Well Log
Permit Number: OSP171028 Date of Issue:3/16/2017
Date Started:11/14/2017 Date Completed:11/17/2017 Is well located at approved permit location?U Yes I No
Legal Description:Spenard Heights Addition Lot4
Property Owner Name&Address:Hahn Vicky D
6521 Thurman Dr.
Anchorage,AK 99502
Borehole Data: Depth(ft) Method of Drilling U air rotary U cable tool
Soil Type,Thickness&Water Strata From To Casing type:steel •
stickup 0 2 Wall Thickness: .250 inches
overburden 2 4 Diameter: 6 inches Depth: 325 feet
Liner Type:
sand 4 8 Diameter: inches Depth: feet
clay w/gravel 8 22 Casing stickup above ground: 2 feet
clay 22 89 Static water level(from ground level): 90 feet
black sand 89 111 Pumping level: feet after
hours pumping gpm
wet clay 111 173 Recovery Rate: 30 gpm
sand 173 221 Method of Testing: airlift
wet clay 221 238 Well Intake Opening Type:
clay,w/coal &H2O 238 263 n Open End n Open Hole
sandy silt w/gravel & H2O 263 285
ill
Start feet Stopped feet
n Perforations Start feet Stopped feet
clay 285 315
Grout Type: Bentonite Volumc:granules
gravel w/H2O 315 325 Depth: 20' Start 0 feet Stopped 20 feet
•
Pump: Intake Depth 190 feet
Pump size 3/4 hp Brand Name SQE Grundfos
Well Disinfected Upon Completion?n Yes[1 No
Method of Disinfection;.chlorine tablets
Comments:
Well Driller: Hefty Drilling, Inc.
3540 Akula Dr.
Water Sample Results:
1
�'r \ Anchorage,AK 99516
Arsenic: )1/D ug/L (6
Nitrates: Nle mg/L
Total Coliform Bacteria: 11e5 colonies/100mL
Other Bacteria: le), col/100mL r
Attention: The well driller shall provide a well log to DSD within 30 days of completion.
I _ _
Development Services Department
Building Safety Division •
.�.� Cati a
On-Site Water & Wastewater Program oma'
K: .
a
4700 Elmore Road
P.O. Box 196650 < 'IA I i
Mark Begich Anchorage, AK 99507 SA ETY
Mayor www.muni.orq/onsite
(907)343-7904
Pump Installation Log
Well Drilling Permit Number-'95p 171 b ? Date of Issue: /01/2417
Parcel Identification Number:
Legal Description Property Owner Name&Ad ess:
5f ^ te1914s Mott - o-) VicLi D }+a -1n
Lv i- L4 cos-;--(t Ti iii-mc .. or
Pump Installation Date: / , '-, i 0
Pump Intake Depth Below Top of Well Casing:/c10 feet
Pump Manufacturer's Name: G f U N d -.,5
Pump Model: /0 50: 07- )C&2
Pump Size 3itt hp
Pitless Adapter Burial Depth: '0 feet
Pitless Adapter Manufacturer's Name: Py. 1D
Pitless Adapter Installer:
Well Disinfected Upon Completion?Elk Yes IT No
Method of Disinfection: C►// /P'I_ „1 ��0 S
Comments: l �^
Pump Installer Name: -lefty Driftingt-
I6 4ti
kG P.O.Box 12130
Anchorage,AK99511
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
MUNICIPALITY OF ANCHORAGE
On -Site Water & Wastewater Program
PO Box 196650 4700 Elmore Road
Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997
http://www.muni.org/onsite
Permit Number: OSP171028
Work Type: Well Initial
On -Site Water System Permit
Effective Date:
Expiration Date:
Tax Code Number: 01205242000
Site Legal Address: SPENARD HEIGHTS ADDITION LT 4 REMAINDER G:2026
Site Mailing Address: 3708 JEWEL LAKE RD, DLIPL, Anchorage
Owner: HAHN VICKY D
Design Engineer:
This permit is for the construction of:
❑ Disposal Field ❑ Septic Tank ❑ Holding Tank ❑ Privy
ell
O� Is"
r
Departmell t
3/16/2017
3/16/2018
Lot Size in Sq Ft: 14385
Total Bedrooms: 4
Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Special Provisions:
To close this permit please submit the following within 30 days after completion of the well:
1. Well log
2. Pump install log
3. Water sample results
10/31/1
C-0 :41 - "C" teej .
Received By: -A r (---- Date:
Issued By: (�TC�Y Date: 3Flo Q
116 16
/I z, /u
100' SEWER
SETBACK
O CO
6��'���
O CO
25' SEWER
SETBACK
LOT 4
•� 75' SEWER MAIN \ i
�O • / O SETBACK
O
. ,
/ w
Ln
Ln
LOT 3
m' o O
�� , PROPOSED WELL o ��� i�/ i� EXISTING N
m I SITE LOCATION O ,� ��� � ��� , HOUSE
SHEDS
Ln
CD
i �•
0
o 5890 59"27"W 116.25- S890 59'27"W 116.25
z
\ LOT 5 / 100' EXISTING
/ f WELL BUFFER
LOT 6 100' EXISTING
\ f WELL BUFFER /
EXISTING WELL /
100' PROPOSED LEGEND:
\ WELL BUFFER / / 0 PROPOSED WELL
SEWER MANHOLE
POSSIBLE WELL LOCATION
EXISTING ---- PROPOSED WELL BUFFER
WELL GAS AND OTHER UTILITY LOCATIONS ARE APPROXIMATE. -- - LOT EASEMENT LINE
Know mats below. CALL 811 FOR LOCATES PRIOR I TO DRILLING. Sc. - -SEWER LINE SETBACK
Call a fro yoemg. SEPERATION DISTANCES AND SETBACKS PER - S -SEWER LINE
AMC 15.55.060 TO BE VERIFIED BY DRILLER - - -UNDERGROUND GAS LINE
SPENARD HEIGHTS ADDITION SUBDIVISION DRAWN BY: PS
CG CHECKED BY: SC
-Mr~ Inc LOT 3 REMAINDER AND LOT 4 REMAINDER DATE: 10/31/2017
mtcPti&.c&u—e.96,m.�g.•ounvj g. JOB NO: 15064
>;ag,A WELL SITE PLAN
SHEET N0:
Anchorage, dF 99501 SCALE:
IF(907)243-5629 PARCEL# 012-052-42-000 00
F 19071 243-5629 1 •' = 40'
o-.lcgak.c"m