Loading...
HomeMy WebLinkAboutRIVERPARK VIEW BLK 1 LT 2Onsite File Municipality of Anchorage On-Site Water and Wastewater Program •(907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: QSP171053 PID Number: 067-041-32 Dwelling: ■❑ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑■ New ❑ Upgrade Name: Troy Davis Homes, Inc. ABSORPTION FIELD Address ❑ Deep Trench [' Shallow Trench El Bed ❑ Mound 1689 Knik Goose Bay Rd, Ste 400, Wasilla, AK El Other Phone Number of Bedrooms Soil Rating Total depth from original grade 250-4989 5 1.2 GPD/SF 8.4 Ft LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 4.2 Ft. 4.2 Ft. Riverpark View Estates 1 2 Fill added above original grade Gravel length Township Range Section 0.5 Ft 63.0 Ft. Gravel width Beds: Number of Lines 'Distance between lines SEPARATION DISTANCES 5.0 Ft. Ft To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist between trenches From Tank Field Tank Line 630 Ft2 1 Ft Well >100' >100' N/A N/A >25' TANK O Septic ❑ S.T.E.P. ❑ Holding ❑Other Manufacturer Capacity Surface Water >100' >100' N/A N/A Anchorage Tank 1,500 Gal. Material Number of compartments Lot Line >5' 10' N/A N/A Steel Two NA --- Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain None Noted Gal. Remarks Pump on level at Pump off level at High water alarm at in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034Tank to D3034 Installer _ drainfield Northern Excavation Drainfield D3034 CO/MT D3034 Inspector Ben Schiller BENCH MARK (Assumed elevation) 100.0 ft Inspection 1s' 5/9/175/10/17 5/10/17 Location and description Gates: - 4„ Finish floor, NE garage door COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Fig_ e �� Conditional Approval: Date �� '•• A•,� •. 1.or � i . : 4 •'• :* M • ;, Ili 1 `r+:'Al' • � Vl.i e�i3�M Of ..... ciE Ty .e r 0 OP Approved f il`e-C4' ? Date 1 0/307 �t1,11..1% • , �� Inspection Report_9-1-12.doc RIVERPARK VIEW ESTATES, BLOCK 1 LOT 2 PERMIT # OSP171053 PID # 067-041-32 .--1 LOT 2 / -.-, LOT 5 / --, 1500-GAL SEPTIC TANK LOT —_, RIVERPARK VEW ESTATES —_, ..• . • •• " .•.. —_, BLOCK 1 ALTERNATE SITE .. '• ----i_ _, • -. A B C TH 4 ' • \ FCO 4.2 9.8 I\\ -col fiti LOT 3 SVi ' 18.7 65.0 f..mi. .2ci ;f -.0 i.. FCO V2 v 0 \ 4:.41.40\.•• 5-BDRM HOME I \ 2C0 . 304 , 69.4 . CO1 54.4 91.7 . . \ \\ \\\ • • I , „ MT1 CO2 53.8 89.9 \\ \\ c12 .r 1 •-....... \ • go 1-..... -----1":%-. 'N......\ _,,,-......... WELL I ------ ----,... \\ \ - / -----:%."•••-•-__ '`......... . -_,............. N......\\ \ \ 1 -------_,""•:•.. ‹..-- ......... \ ...</j •....... - , -----*--"- - '-, ib, ,. % ..-*"..- , ....,... \ - ----I":'• --___ '1'... .„1,,,,,,0 ../". .., ••••...... \ .•••"... LOT 1 ....,.... ...i....---,. .. +-77c* pt ...942 0 '`....,,__ I %IS', / p LEGEND ,1111",--....1 ef MT-MONITORING TUBE r % Benjami ' chiller : if, AEL 12592 .•.4-.e, FCO-FOUNDATION CLEANOUT TH-TEST HOLE iro,.‘/(0;!..0,127,2017 .'',..4.,.. 0 50 100 SV-SEPTIC VENT FEET CO-CLEANOUT 1"=50' RIVERPARK VIEW ESTATES, BLOCK 1 LOT 2 PERMIT # OSP171053 PID # 067-041-32 MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT: 343-7904 4700 ELMORE RD, ANCHORAGE, AK 99519-6655 WASTEWATER DISPOSAL SYSTEM OR WELL INSPECTION REPORT CV O O 5 > 0 cq — — ,-91.9 — — — 86.9 �v 87.7 �-86.1 86.4 i soo GA i 86.3 SEPTIC TANK 90.5 FINISH GRADE 0g 90.0 ORIGINAL GRADE O0 I� Iii____ / I 85.8DRAINFIELD ROCK - 85.8 81.6 81.6 63' 72.0 c.-_r\\_ = NO GROUNDWATER 5/28/16 I- SOP / i0*• , . TH I ••*T/ I 1.00 / 012 , •: Benjami (.chiller : O. PROFILE AS—BUILT oifp�;�l.. AL1p592 .� (NO SCALE) +ik��``"`l*.. Wheaton Water Well, Inc. 1190 N. Wasilla-Fishhook Road Wasilla, AK 99654 (907)376-2041 Name: Troy Davis Homes, Inc. Address: 1689 Knik Goose Bay Road, Suite 400 City: Wasilla State: AK Zip Code: 99654 Well Site: Riverpark View Lot: 2 Block: 1 Additional: Permit #OSP171053 Well Depth: 141 ft. From: To: Formation: Below Ground: 139 ft. 0 3 stickup, silt Above Ground: 2 ft. 3 17 wet brown silt, gravel 17 122 wet gray silt Gal/Min: 15 122 127 silt, gravel Static Level: Artesian 127 141 gravel, water Casing: 141' of 6" ID Steel Liner Pipe: none Screened: none Perforated: none Grouted: Bentonite WATER QUALITY TESTING CoI$bTm Abse 1 _Co1/100mL Depth: 20'+ Nitrates 1. a _ mg/L Arsenic <m R Lupit Develop. Method: Air `' V-1 Use of Well: Residential Drilling Method: Rotary Fluids Used: none Pump Installed: none Other: none pate Drilled: 5-25-2017 Driller: Ben Mattson Development Services Department Building Safety Division • 7.4 '"e On-Site Water & Wastewater Program e' <o 4700 Elmore Road P.O. Box 196650 ` ■ll 1 fi Mark Begich Anchorage, AK 99507 s . ETY Mayor www.mur,i.orq/onsite (907) 343-7904 Pump Installation Log Well Drilling Permit Number: SW OSP171053 Date of Issue: 4-19-2017 Parcel Identification Number:067-041-32-000 Legal Description Property Owner Name& Address: River Park View Lot 2 Block 1 Troy Davis Homes, Inc. Clemens Circle 1689 Knik Goose Bay Road A400 Eagle River,AK Wasilla,AK 99654 Pump Installation Date: 10-13-2317 Pump Intake Depth Below Top of Well Casing: 93.5 feet Pump Manufacturer's Name: Myers Pump Model: 3NFL52-12 Pump Size 1/2 hp Pitless Adapter Burial Depth: 12' feet Pitless Adapter Manufacturer's Name: Harvard Pitless Adapter Installer: Unknown Well Disinfected Upon Completion? Z Yes ❑ No Method of Disinfection: Chlorine tablets Comments: 12 GPM Pomp Installer Name: Wheaton Water Well, Inc. 1190 N.Wasilla-Fishhook Road Wasilla.AK 99654 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. JKLIPALITFO MUNICIPALITY OF ANCHORAGE mint S • On-Site Water&Wastewater Program ' s r Anchorage,Alaska 99519-6650 Phone: (907)343-7904 Fax:(907)343-7997 °' 'r http://www.muni.org/onsite , .; _ Department NMOCRp' On-Site Water & Wastewater System Permit Permit Number: OSP171053 Effective Date: 4/19/2017 Work Type: WellSeptic Initial Expiration Date: 4/19/2018 /� Tax Code Number: 06704132000 d d"` 5--9_ 17 Site Legal Address: RIVERPARK VIEW BLK 1 LT 2 G:0364 TO 5(10 f 11 Site Mailing Address: Owner: TROY DAVIS HOMES INC Lot Size in Sq Ft: 69740 Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 5 This permit is for the construction of: 0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy 0 Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: /; / M/a )'v 6 pOU Date: Issued By: I ' ,� Q - $1j2 Date: .20 F6�B9lp `'v MUNICIPALITY OF ANCHORAGE AH i 7 211 Community Development Department Phone: 907-3, g Development Services Division Fax: 907-343-7997 On-Site Water& Wastewater Program ON-SITE SEWERNVELL PERMIT ;G ` ICATION 067-041- Parcel I.D. ,/.zu Property owner(s) Troy Davis Homes Day phone 310-2501 Mailing address 1689 S. Knik Goose Bay Road #400 Wasilla, AK 99654 Site address 21371 Conley Avenue Chugiak, AK 99567 Legal description (Sub'd., Block & Lot) Riverpark View, Block 1, Lot 2 Legal description (Township, Range & Section) Lot Size Sq. Ft. Number of Bedrooms Five (5) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (El all that apply) Absorption Field 14 Initial ❑ Single Family (SF) 0 (w/wo ADU) Septic Tank ( Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well El Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE I WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 14-c-d.4zie z LeL (Signature of property owner or authorized agent) Permit/Rush Fees: sse ' ! g 4- Waiver Fees: Date of Payment: 41// -- 1?' Date of Payment: Receipt Number: 6S Receipt Number: Permit No. OSP/7/653 Waiver No. Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) April 16, 2017 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Block 1 , Riverpark View Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Block 1, Riverpark View Subdivision intends to construct a new five-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and the existing septic systems and wells on this and adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test holes placed on the lot in the area of the absorption trenches and alternate site indicate gravel (GM/GW) with varying amounts of sand and silt. The percolation rate of the soil was determined to be 1 to 5 minutes per inch. No groundwater was found during the placement of the test holes and none was found in either test hole during the monitoring period. An application rate of 1 .2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,500-gallon septic tank and a 63' long by 5' wide by% effective'depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 4.0' below the surface and the total depth will be 8.0'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. 1 The ground surface on the lot in the area of the septic system slopes to the southeast- at outheastat a shallow grade. The new trench will be constructed parallel to the ground contours in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. Lot 2, Block 1, Riverview Park April 16, 2017 Page Two If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, 74-4--L4.1 Michael E. Anderson, P.E. Attachments ••• OF • ai21, 404, NCI-SAFIE. ANDERSON 0 J,'.. CE-4381 4`? #IOr<^�,.•.47-17,••��v�rr 41.404?.AillO0N.- •„-..._ i-' :. \..,\ 11%4.11\1\I1 -� 166.81' N 8••-8 .. `o 4 EASEMENT— \\. 0' T& \ 444h1/4 \`:`\\\\\\\\\\\\ EMENT At:\.‘1111111111 .ci Po, \ \ N. , . 10,4.„.\\,,,,,\-\\\\„ 41,11 , , . . •., ....„...„ , F S q0 *dir y ,� Ri,F ti s8 , � .0-5e . , 1 ? , >5� •41'of 6849,7.. hl �O 0 �\Q w S s '4 ooy,� �oa�J? LOT 0 ln m i ITI BLOCK 1 , LOT 2 �,...... RIVERPARK VIEW ..•-\F.-, � ��,��, SUBDIVISION .�P.••••'••"""' • � . _ 69,740 s.f. i G7 r _ • I %. �1 i. • 49th iN `, I. AREA MAP .. -. ♦,VI;MICHAEL E. ANDERSON !• i% SCALE 1' = 100' �, �1 NO, CE-4381 - •♦.44.° ROFESSI''�''• \ • ` \ `;, LO 179.90. --� `�, \�, n 6 ' Long Wide x �— \\\ �`• ~ " • 4' Effective Dep vvvv v Absorptn Trench i V) Rte, � 3 `\`\ 2Q; •• \ '�_ 9if� TM 1,500 Goll° _ — �;`� \\\\ ..„..);,,,\\\• �___. ,. • eco -.tic Tank, — _. — \\\ �•`�\ FCO ` \\\�1• `\ FWE Bao c., %Iiiiiiiiik1/4 • \ \ i HOME \ \ • i . \\ I , ' • ,.� , \\ -mimed Well ��' No Conflicts with Wells I . )1 — .. • or Septic Systems on `\ ti 1°3' �� 1 BB40.�a . Neighboring Lots. \` ` 'gm , 1 // r ly \, 4` 1 dD'•N \ / ,/ .4°4)7. o7. . \> J6T e, / qG �, ,\ `.•-•(E+oF�R''+•� -\,frF7///s:////////////////////////////////////itittS ,fl ,'/ \� LOT 1 "c-,./ c-,. . ` Q. . 9. .\� dp \\ I��/ Proposed i•• ' '49th • `•f \ 0q0 . 'i • Well ...ev4Li. ... ....... `� -- — LEGEND f9 ci.-•MICHAEL E. ANDERSON 4't p N. SV — Septic Vent �' '••'�"''-'7•• BLOCK 1 , LOT 2 CO — Clean Out •jj .... ����� �\ \ MT — Test�tHole ube �;;;5�;;'• RIVERPARK VIEW SUBDIVISICN CONTOUR INTERVAL — 4' SITE PIAN 69.740 sf_ ��,\ SCALE 1' = 50' \ ` LOT 2, BLOCK 1 , RIVERPARK VIEW SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Five Bedroom Home 5'Wide Trench System Perc. Rate: 1 - 5 Min./Inch 1,500 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 5 Bedroom4 X 150 GPD/1.2 GPD/SF (Application Rate) = 625 SF Absorption Area 625 SF/5 SF/LF*.5 (Red. Factor) = 62.5 LF Trench Length THEREFORE: Construct a 63' Long x 5'Wide x 4' Effective Depth Absorption Trench at the Location Shown on the Site Plan. Flowline Elevation in the Trench to be Placed at 4' Below the Existing Ground. Total Depth of Trench to be 8' Below Existing Ground. Place a Minimum of 4' of Cover Over the Septic Tank and 3'of Cover Over the Trench or Place 2" of Insulation and 2' of Cover. All Elements of the Septic Sytem Must be a Minimum of 100' From All Private Wells in the Area. Natural Backfill 3'6" Geotextile Fabric 6.. O 4" Perforated — - PVC (Holes Down) Drainfield Rock 4'0" 5' I I TYPICAL DEEP TRENCH SECTION (NO SCALE) �: MUNICIPALITY OF ANCHORAGE 4031 _rtti� DEVELOPMENT SERVICES DEPARTMENT .�PSE O.. 44/.. 99519-6650 c'• 1 �• 4700 BRAGAW STREET ANCHORAGE, AK4• 49th 7� ';*. SOILS LOG - PERCOLATION TEST MICHAEL E. ANDERSON = j LEGAL DESCRIPTION: LOT 2, BLOCK I, RIVER PARK VIEW SUB. ��.:�:o No%c-gat�C�-•ti.' PERFORMED FOR: TROY DAVIS HOMES •'" .. P •0 DATE: 5/19/16 PROJECT No.: •,l� �s0 ��• PARCEL ID#: TECHNICIAN: W. ROBERTS Professional Engineers Stamp DEPTH TEST HOLE 3 (feet) OB/OG SLOPE SITE PLAN 1 d 2 3 a 4 5 SEE SITE PLAN • A d 6 4 A 7 4 8 SILTY GRAVEL WITH SAND 9 a a GM/GW WAS GROUND WATER ENCOUNTERED? No 1 a IF YES @ WHAT DEPTH', • DEPTH OF WATER AFTER MONITORING: NONE LE 11 a DATE OF MONITORING: 5/28/16 •12 L GROSS TIME NET TIME DEPTH TO NET DROP 13 d DATE READING (MINUTES) (MINUTES) (NATER (INCHES) (INCHES) 14 .' TEST HOLE PRESOAKED PRIOR TO TESTING: 15 5/28 1 1:06/1:16 10 0.75"/3.25" 150" 2 1:17/1:27 10 0.50"/3.00" 2.50" 16 3 1:28/1:38 10 0.75"/3.25" 2.50" 17 4 1:39/1:49 10 0.88"/3.38" 2.50" 18 BOH @ 18' 5 1:50/2:00 10 0.75"/3.25" 2.50" 19 6 2:01/2:11 10 0.75"/3.25" 2.50" 20 -- PERCOLATION RATE: 4.0 (MIN/INCH) PERC.HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I,MICHAEL E.ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/13/16 MUNICIPALITY OF ANCHORAGE �t>.>t��,, DEVELOPMENT SERVICES DEPARTMENT �� �� •• 1 • 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650V)''• ,.. i 49th SOILS LOG - PERCOLATION TEST MICHAEL E. ANDERSON f G1 : LOT 2, BLOCK I, RIVER PARK VIEW SUB. `♦r Na. CE-4381 �� i LEGAL DESCRIPTION: s .Y:�7�7,.• ° '••• PERFORMED FOR: TROY DAVIS HOMES �1+,�`p •• DATE: 5/19/16 PROJECT No.: PARCEL ID*. TECHNICIAN: W. ROBERTS Professional Engineers Stamp DEPTH TEST HOLE 4 (feet) OB/OG SLOPE SITE PLAN 1 d 2 3 4 5 a SEE SITE PLAN (. Q 7 e 8 SILTY GRAVEL WITH SAND 9 —R •4 GM/GW d ' 10— V WAS GROUND WATER ENCOUNTERED? NO IF YESgi WHAT DEPTH' DEPTH OF WATER AFTER MONITORING: NONE 1 1 DATE OF MONITORING: 5/28/16 12 GROSS TIME NET TIME DEPTH To NET DROP 13 DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 TEST HOLE PRESOAKED PRIOR TO TESTING: 15— • • 5/28 1 2:33/2:43 10 0.75"/4.88" 4.13" 2 2:44/2:54 10 0.75'75.00" 4.25" 16— • 3 2:55/3:05 10 0.63'74.88" 4.25" 17— ea 4 3:07/3:17 10 0.50"/4.63^ 4.13" 18— BOH @ 18' 5 3:18/3:28 10 0.75"/5.00" " 4.25 19 6 3:29/3:39 10 0.63"74.88" 4.25" 2O PERCOLATION RATE: 2.2 (MIN/INCH) PERC. HOLE DIA. 6" (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. 1,MICHAEL E.ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 6/13/16 ON-SITE WASTEWATER DISPOSAL SYSTEM CONSTRUCTION AND MATERIAL SPECIFICATIONS SUBJECT: LOT 2, BLOCK 1, RIVERVIEW PARK VIEW GENERAL: 1 . The scope of this project includes the procurement and placement of a new 1,500-gallon septic tank at the location shown on the Site Plan. Work also includes the construction of a new 63' long x 5' wide x 4' effective depth absorption trench at the location also shown on the Site Plan. The distribution line in the trench will be placed at 4.0' below the existing ground surface. Total depth of the trench will be 8.0' below the existing ground surface. The new absorption trench and septic tank must be placed a minimum of 100' from all private wells and any surface water in the area. A minimum of 2' of cover with insulation is required over the absorption trench and 4' of cover over the septic tank. 2. Construction shall be in accordance with the approved site plan, design drawings, Municipal Permit with any special provisions or conditions, and all applicable State and Municipal Wastewater Disposal Regulations. 3. The Contractor shall be responsible for obtaining all underground utility locates and for the layout of the septic system and verification of the location of all lot lines. The Contractor must also verify the location of wells in the area and assure that the separation distances are met. 4. Unless specifically agreed otherwise, the contractor shall be responsible for final grading areas subsequently depressed from soil settling. Property owner shall be responsible for revegetation of affected areas unless specifically agreed otherwise. 5. Contractors installing wastewater disposal systems must be certified by the Municipal Building Safety Division On-Site Water and Wastewater Program for system installations. Owners installing their own systems must receive prior approval from the On-Site Water and Wastewater Program before beginning system installation. SEPTIC TANK INSTALLATION 1 . A new 1,500-gallon septic tank must be procured from an approved source and installed at the location shown. 2. A septic tank is to be constructed by a certified septic tank manufacturer. Construction shall include two 4" cleanouts for pumping access. 3. The septic tank shall be sufficiently bedded to prevent settling or shifting of the tank. 4. All standpipes on the septic tank shall extend a minimum of 12 inches above final grade. 5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial insulation. 6. A foundation cleanout shall be installed one to four feet from the building foundation. Two cleanouts are required between the tank and the drainfield. 7. Final grading over the tank shall be such that a positive slope exists away from the septic tank. DRAINFIELD CONSTRUCTION: 1. The drainfield shall be constructed to the dimensions shown on the design. The bottom of the trench shall be within 2" of level. 2. Distribution piping must be placed level with perforations down atop a level bed of drainfield rock. Rock should then be placed over the pipe to provide a minimum of 2" of cover. 3. A silt barrier or geotextile fabric must be placed between the drainfield rock and the natural soil backfill. 4. Monitor tubes must be 4" in diameter and installed at the locations shown on the design. The portion below ground must be perforated. 5. Contractor shall verify the septic tank and drainfield are a minimum 100' away from any private water wells in the area, 150' from a Class "C" Well or 200' from any community well. 6. Direct bury insulation must be placed over the distribution system if less than 3' of backfill depth is available. Finish grade over the trench must be mounded to prevent settlement or depressions. 7. The area surrounding the absorption trench must be graded to drain away from the trench. 8. A minimum 2' of accepting soil is required below the drainfield rock for a 5' wide trench. All pockets of unacceptable materials must be removed and replaced. MATERIAL SPECIFICATIONS: 1. Septic tanks must be constructed by a municipally approved septic tank manufacturer. 2. The following pipe materials are approved for use in septic system installations in the Municipality of Anchorage: Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662 or A.B.S. (perforated and solid). 3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow Chemical Co. Styrofoam HI or equal). 4. Septic tank inlets and outlets shall be fitted with watertight couplings (Caulder, Fernco, or equal). 5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed between the final drain rock layer and the native soil layer. 6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the #200 sieve. INSPECTIONS: Municipal Ordinance requires a minimum of two inspections. These inspections must be conducted under the supervision of a professional engineer registered in the State of Alaska. The first inspection must be conducted after the excavation of trenches, beds or pits and before the installation of any gravel. A septic tank may be set in place, but may not be backfilled. The second inspection must be conducted after the placement of the geotextile fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No backfill should be in place at the time of inspection. Contractor shall provide a copy of all field survey layout and construction notes for use in preparing the certified as-built of the completed system. R• g910 Uf a • !r--- Municipality of Anchor. ti 0.1z, A On-Site Water and Wastewater Pro. - iiia"=: :. z (907) 343-7904 OCT 26 2017 ID 5a < <TY Certificate of On-Site Systems A 6 oval }/\' 067-041 -32 G'[ 6s Parcel I.D. Expiration Da e: Jan 30 oZQ ig 1. GENERAL INFORMATION Complete legal description River Park View Block 1 Lot 2 Location (site address) 6900 Clemens Cir Current Property owner(s) Troy Davis Home Inc. Day phone (907) 357-9394 Mailing address 1689 S Knik Goose Bay Rd #400, Wasilla, AK Real Estate Agent Day phone 2. TYPE OF DWELLING: n Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 5 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well Individual ❑ Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ WaiverNariance request for: Distance: Received by: Date: kJ e r(7 COSA to be released to the eng er,unless otherwise requested by the engineer. COSA Fee $ ///4Y Waiver Fee $ Date of Payment 4Q/a?1/9 Date of Payment Receipt Number 0 L Receipt Number COSA# 0607-/ Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER s. As certified by my seal affixed hereto and as of the validation date shown below, I Verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, fuhctional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, he on-site water supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, ordinances, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone 907-522-7773 Address 1399 W. 34th Ave. Suite 203 Anchorage, AK 99503 Engineer's Printed Name Benjamin Schiller Date 10/25/17 •irdv e f' 6. DSD SIGNATURE �- Ifo,, . • ,,.....•.. 5 System #1 Approved for bedrooms {{'�" / p .`� o t �.• in J a:T y °' System #2 Approved for bedrooms e,, Disapproved �'� °�o°•!1`1� i?-••.E�0� vre Conditional approval for bedrooms, with the following stipura ibbs.T.-:^-� \ t tdlltt • tt: 0/1 ,440 _odpao Cf) ? eco. to 4° ?41ENTS � - By: 616Y,(1/()A Original Certificate Date: U .3�J/201 f The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet f - If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: River Park View Block 1 Lot 2 Parcel ID: 067-041 -32 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (YIN) Y Date completed 5/25/1 7 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 141 ft Cased to 141 ft. Casing height (above ground) >18 in FROM WELL LOG AT INSPECTION Date of test 5/25/17 New Static water level Artesian ft ft. Well production 15 g.p.m. g.p.m WATER SAMPLE RESULTS: Coliform ND colonies/100 mL Nitrate 1 .23 _ mg/L Arsenic ND ug/L Date of sample: 10/17/17 Wheaton Water Wells Collected by: B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel Date installed 5/10/17 Tank size 1 500 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA 1.2 GPD/SF Date installed 5/9/17Soil rating (9Pd./ft2 or ft2/bdrm) System type 5 Wide Length 63 ft. Width 5 ft Gravel below pipe 4.2 ft. Total depth 8.9 ft. Eff. absorption area 630ft2 Monitoring tube Y Depression over field N Date of adequacy test New Const Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g p.d. Any rejuvenation treatment(past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (YIN) "Pump on" level at in. "Pump off' level at in. High water alarm level at in. Datum Cycles tested Meets alarm &circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot 100' On adjacent lots 100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >5' >5' >5' Building foundation Property line Absorption field Water main >10'10' Water service line >10'10' Surface water >100' Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: >10' Property line 1 Building foundation 1 Water main Water Service line Surface water Driveway, parking/vehicle storage Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS G. ENGINEER'S CERTIFICATION ,, �Vsy+�li! / certify that I have determined through field inspections and p1 C1 F g qiI, review of Municipal records that the above systems are in a.4SP ?•;• -r ��'•.sf.1l conformance with MOA COSA guidelines in effect on this date. *• 4 T'� :9 Is •4 % Engineer's Printed Name Benjamin Schiller, PE • _ � ••••••:...; Date 10/25/17 �IK...4i,31 Sc " t COSA brown sheet 10-10-12.doc Lot 5 Lot 2 Il// / Lot 4 N 89'53'25"E 166.81' N 89'38'33"E 144.99' S 79.06. \ h 20' T&Eer 36 E 17g.9p. ° ` a/ EASEMENT SEPTIC PIPES _ _ _ _ — \ \ O J 6.76' 30' T&E a, S 62'01'59"E N EASEMENT in63.73., \\ \\ #111111v; 'o \ t1/4316 \\ R=loo' Lot 3 s ( \\ PROTECTIVE V 3 HOUSE DETAIL qC� \ \ RADIUS WELL 66'49'79„ I n SCALE: 1"=30' F ^/ Lot 2 F 347 I 1— • Pi N 1j' N �.\ 69,740 s.f. •36 ss, I Pi �• 22 7 N. ��� 3 OO�, N 6,9....49,_ _ a 11.0 2.0' RO` •13 k. .T� Z m 136 �Q GRAVEL DRIVEWAY 11.0 �Z �S Op N 2 STORY RESIDENCE o � ^'• w/ WALKOUT BSMT. .o �--. Lot 1 0 a.a 20.x• I n 1- 1.5'x4.1' cp 4,0 1 mu CANT 0. N N 21 2 w000 2.0' CANT PLOT PLAN AS BUILT X SCALE 1" = 100' GRID SW 0363 Protect No. 17-053/B5 11500 Daryl Avenue, Anchorage, Alaska 99515-3049 Lang & Associates , inc . (907) 522-6476 Phone oopCOp 0 ke(9O7)nOlan22-4625 su ey comax .=71.,Q�r .q L 4%� Professional Land Surveyors g ....•• •....:11/4s,1:1 .. ,q 11 jonathanOlangsurvey.com O ...".'f. S I herebycertif that I have surveyed the followin described property: QOCP �'\ �oo LOT 2, BLOCK 1, RIVERPARK VIEW SUBDIVISION (PLAT2017-23) y 49TH /\ � �� Anchorage Recording District, Alaska, and that the improvements situated thereon are within the property lines and do not encroach onto the property adjacent thereto, that 1 , ...4"--- D no improvements on the property lying adjacent thereto encroach on the surveyed ��o 1 KENNETH GS LANG 4� premises and that there are no roadways, transmission lines or other visible �, easements on said property except as indicated hereon. �n J'� �' i3f L"7 Q� VV .••.LS-5202.•'' gJp� Dated this the Day of :.%�-T La ry , ___�, at Anchorage, Alaska 41144,0 '•••••• X . /PortSSIONA1-�o It is the responsibility of the owner to determine the existence of any easements, ���00000a covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963