�, ""rr MUNICIPALITY OF ANCHORAGE
I; ". On-Site Water&Wastewater Program ��� 5;:.
7,.. PO Box 196650 4700 Elmore Road
I; Anchorage,Alaska 99519-6650 Phone: (907)343-7904 Fax:(907)343-7997 r.
http://www.muni.orgionsite v
i
___ clrirtntenf
4HCH DR
— On-Site Wastewater Disposal System Permit
Permit Number: OSP171044 Effective Date: 5/25/2017
Work Type: Septic Initial Expiration Date: 5/25/2018
Tax Code Number: 05106203000
Site Legal Address: EKLUTNA HEIGHTS BLK 1 LT 3 G:1461
Site Mailing Address: 24244 MOUNT EKLUTNA DR, Chugiak
Owner: TROY DAVIS HOMES INC Lot Size in Sq Ft: 43560
Design Engineer: TROY DAVIS HOMES INC Total Bedrooms: 4
This permit is for the construction of:
0 Disposal Field 0 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well 0 Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: tetitie404110 ) Date: D.
Issued By: 'i a -rz- / Date: 5 25 .2o it
MUNICIPALITY OF ANCHORAGE
Community Development Department // Phone: 907-343-7904
Development Services Division Fax: 907-343-7997
On-Site Water & Wastewater Program
ON-SITE SEWER/ YELL PERMIT APPLICATION
Parcel I.D. 051-062-03
Property owner(s) Troy Davis Homes Day phone 310-2501
Mailing address 1689 S. Knik Goose Bay Road #400 Wasilla, AK 99654
Site address 24244 Mount Eklutna Drive Eagle River, AK 99554
Legal description (Sub'd., Block & Lot) Eklutna Heights, Block 1, Lot 3
Legal description (Township, Range & Section)
Lot Size _ 43,560 Sq. Ft. Number of Bedrooms Four (4)
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field 0 Initial ❑ Single Family (SF) El
(w/wo ADU)
Septic Tank 0 Upgrade ❑
Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well ❑
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of property owner or authorized agent)
Permit/Rush Fees: ` coq Waiver Fees:
Date of Payment: -Ia`149' Date of Payment:
Receipt Number: /�, 6/368 06 r' Receipt Number:
V
Permit No. c5 PI-410(W Waiver No.
Permit App_9-1.12.doc
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
May 25, 2017
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 South Bragaw Street
Anchorage, AK 99519-6650
Subject: Lot 3, Block 1, Eklutna Heights Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 3, Block 1 , Eklutna Heights Subdivision intends to construct a new
four-bedroom home on the lot. A well is currently in place on the lot and will be utilized
to serve the house. We are therefore requesting a permit be issued for the construction
of a new septic system to accommodate the home. The attached Site Plan and backup
documentation identify the location and configuration of the existing well and proposed
septic system along with the alternate site. Also identified on the plans are the existing
wells in the area and septic systems on surrounding lots. No conflicts exist between the
proposed septic system and the existing septic systems and wells on this and adjacent
lots. Drainage arrows are shown on the site plan showing the grade and direction of
flow on the lot. The drainage pattern will not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption trenches and alternate site
indicate gravel (GM) with varying amounts of sand and silt. The percolation rate of the
soil was determined to be 4.8 to 12 minutes per inch. No groundwater was found
during the placement of the test holes and none was found in either test hole during the
monitoring period. Groundwater was checked on May 15, and water was found at 13' in
one test hole and 14' in the other. This information was added to the test hole logs. An
application rate of .8 gallons per day per square foot was used in the design of the
absorption system. We are proposing to place a new 1,250-gallon septic tank and a 63'
long by 3' wide by 6' effective depth absorption trench to treat and dispose of the
effluent generated in the house. The elevation of the distribution line in the absorption
trench will be 3.0' below the surface and the total depth will be 9.0'. A minimum of 3' of
fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over
the septic tank.
The ground surface on the lot in the area of the septic system is flat with only a very
shallow grade to the southwest. The new trench will be constructed in conformance
with Municipal requirements. The new septic system will be constructed a minimum of
Lot 3, Block 1, Eklutna Heights
May 22, 2017
Page Two
100' from all wells and any surface water and 10' from the proposed and existing water
services in the area. The septic line will be located a minimum of 25' from the well.
If the system is constructed in accordance with our design the following statements
apply:
1 . The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed. will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
,a�� �,�.� .
Sincerely, 40," 4, 41,
•
os Cr • dd
Benjamin Schiller. P.E.
Attachments
�T, JlPYtiZ ESSPI {tx
MOUNT EKLUTNA DRIVE
I i
1. La*4 eilaKµ 5 .._
m ,/=u 2
I
{
/
/ N
I MOW,ram /
MIMI DIY[ / \
\
l
l I
WAIT \
\ /
\ /N
BLOCK 1 , LOT 3
EKLUTNA HEIGHTS
SUBDIVISION �4��� ��r��, .
:62., ,
AREA MAP :4, ..i_ \ ,.,,,,
- • 49th s
SCALE 1' = 100' 11-11“-'4 " r 1
0i MICHAEL E. ANDERSON'S t:
•t..4 .. 4-7-/73e1 •. 1'
�i44 p�'QFESSI i4
"IIx,..++++
MOUNT EKLUTNA DRIVE
N 89'55'10"E 165.11'
33' ROADWAY EASEMENT
T
1:1)‹i
Q
a Lx.s t ng
I
Wellco
a Existing
N<p Well
,/
it 1 .
Four
Bedroom
House
Y Imo: �-
1,250 Gallon Septic • FCO
W Tank Existing
25.0' Well
MIN
2 U)
0 0
q q
o • CO 0
CP
Lot 4 0
o 0 WEST 1/2 Lot 2
2.4 C,,
N v) IV
<D
in in
4 o
IFI
lir SV T1,250 Gallon
No Conflicts with Wells TH1 Septic Tank
or Septic Systems on • 2C0
Neighboring Lots. eTTH2
CO O
MT 63' Long x 3' Vide x
Alt. Site 6' Effective Depth
____- Absorption Trench. LEGEND
BLOCK 1 , LOT 3 SV Septic Vent
0 o CO - Clean Out
EKLUTNA HEIGHTS TMT CO
- Test Holeube
In inSUBDIVISION CONTOUR INTERVAL - 2'
54,476 5.f.
~ OF� k�1
33' ROADWAY EASEMENT , _
A*:'49I" W �'.*
S 89'55'10"W 165.11' • F
SITE PLAN MIRROR DRIVE � :�, Ben in3chl11eri4 '
!+ 12592 .��
SCALE 1' = 40' t11,,;F�pAOFESS10Na4
Lot 6 Av.....-v`
LOT 3, BLOCK 1
EKLUTNA HEIGHTS SUBDIVISION
DESIGN FACTORS: SYSTEM REQUIREMENTS:
Four Bedroom Home Deep Trench System
Perc. Rate: 6-15 Min.Ilnch 1,250 Gallon Septic Tank
Application Rate: .8 GPD/SF 6' Drainfield Rock
4 Bedrooms X 150 GPD/.8 GPD/SF (Application Rate) = 750 SF Absorption Area
750 SF/12 SF/LF = 62.5 LF Trench Length
THEREFORE: Construct a 63' Long x 3'Wide x 6' Effective Depth Aborption Trench at the
Location Shown. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth
to be 9' Below Existing Ground. Provide 3' of Cover Over Trench and 4' Over Tank or Provide
2"of Insulation and 2'of Cover. Maintain 10' Separation From Water Services in the Area.
Natural
Backfill
2'6"
Geotextile Fabric
6" O 4" Perforated
— PVC (Holes Down)
Drainfield Rock
6'0"
3'
i I
TYPICAL 3' WIDE TRENCH SECTION
(NO SCALE)
NOTE: Grade Area Over Trench to Drain Away. "cQ
Minimum 6' Separation From Bedrock. g•• 9 tr,
Minimum 4' Separation From Groundwater. *.4911 '.#
Minimum 100' Separation From Private Wells in the Area.
Minimum 100' Separation From Surface Water or Streams. .....
•
••. ••• .
Minimum 10' Separation From Water Service Line. / • Benjarni• hiller :
' c• CE 1 92 ,• �f
1 ).• 251017
+'1iF0•May°ROrESS10HA�
MUNICIPALITY OF ANCHORAGE .'isms imailus>
DEVELOPMENT SERVICES DEPARTMENT •�4•••„:• ••••.. +,1�.
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 :.
P : 49th n ; 0
SOILS LOG - PERCOLATION TEST ji'jLL
11-"41 ---k
I/ MICHAEL E. ANDERSON• r
LEGAL DESCRIPTION: EKLUTNA HEIGHTS, BLOCK I, LOT 3 �•�.`. No, CE-4381
PERFORMED FOR: TROY DAVIS HOMES. INC. �1 ••.`� 11 -
DATE: 3/27/17 PROJECT No.: +-� E*�t���+•
PARCEL ID#: TECHNICIAN:
J. M I LLE T T E Professional Engineers Stamp:
DEPTH TEST HOLE No. 1
(feet)
SLOPE SITE PLAN
1 iii
'/ OB/OG
2 ,..r_
32:,...--:-..,,,c-,,'
�
'�44 = _:
4
"'!`' GRAVEL W/SAND
5 —\' ,'-<•; ` AND SILT SEE SITE PLAN
.z• ..r
_• ;" ';; GM
8 ..}i.X
• ;'
•.• `% WAS GROUND WATER ENCOUNTERED? NO
10 .`ti: >"{^: IF YES @ WHAT DEPTH" IS 1L
• .;!::-.._1;.;: .:.-Jr• DEPTH TO WATER AFTER MONITORING: NONr
1 1 [ :` a� 4/6/17
DATE OF MONITORING:
12—�;`„:;: • ^
,1','•':'=``' DATE READING GROSS TIME NET TIME DEPTH
PTER OF NET DROP
13—:_`�; '.? ' (MINUTES) (MINUTES) (INCHES)
(INCHES)
14 .,'' �'s*'. 3/27 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 f'.t>:":: I 11:15 6.00'
16 BOH @ 15.5' 2 11:45 30 3.50' 2.50”
3 11:46 6.00
17— 4
12:16 30 3.50' 2.50"
8— 5 12:17 6.00" _
19 6 12:47 30 3.50" 2.50"
20
PERCOLATION RATE: 12 (MIN/INCH) PERC.HOLE DIA. 6" (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. I,MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 4/7/17
���xx
MUNICIPALITY OF ANCHORAGE 4� xvl`l
DEVELOPMENT SERVICES DEPARTMENT . •q...4 .i+
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 0*.•49TH i� •*ctrl
SOILS LOG - PERCOLATION TEST A .. ... . oor
AI
: r : Ben• in Schiller :
• . �
LEGAL DESCRIPTION: EKLUTNA HEIGHTS, BLOCK I, LOT 3 ��9``�iJJ• cE222992 .�V��r
rl1F9F�PROFESS...............
PERFORMED FOR: TROY DAVIS HOMES. INC. i\�V" ��
DATE: 3/?7/I7 PROJECT No.:
PARCEL ID#: TECHNICIAN: U• Mi LLETTE Professional Engineers Stamp:
DEPTH TEST HOLE No. 1
(feet) -
SLOPE SITE PLAN
1 %� OB/OG
•
3 y:
4 --` r, f.-�
:N :y....' GRAVEL W/SAND
5 —„,<-t�,,�_ AND SILT SEE SITE PLAN
_ .
7 nf. •\,s
^ ".. . ��.. GM
8 :..
'Aw'':r :
9 — '
`.•••Y.::::-- WAS GROUND WATER ENCOUNTERED? NO
, Y.�: IF YES(g WHAT DEPTH'S
..?...:.: :.*:,<:`:::::;!4.
DEPTH TO WATER AFTER MONITORING: 14'
1 1 -:..r.-7:l.;•-!'.7!`V- DATE OF MONITORING: 5/15/17
.:r»;•:S,- DEPTH OF
`4.'. a:=ry DATE READING GROSS TIME NET TIME WATER NET DROP
13� j ,;,
(MINUTES) (MINUTES) (INCHES) (INCHES)
14 '';'.44:''f',..5-.‘•:-'4- 3/27 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 ';`•;-: . I 11:15 6.00”
,1';r -._.: BOH @ 15.5'
16 ? 11:45 30 3.50" 2.50"
.5 11:46 6.00"
17—
- 12:16 30 3.50" 2.50"
1812:17 6.00"
196 12:47 30 5.50" 2.50"
20
PERCOLATION RATE: 12 (MIN/INCH) PERC. HOLE DIA. 6" (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
MUNICIPALITY OF ANCHORAGE r�rrrrrriii
DEVELOPMENT SERVICES DEPARTMENT ���*-- ,. ►it
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 ir ':•14 i +►1
., 49th _ ��` Ii
SOILS LOG - PERCOLATION TEST •
; y� -i . cam.L. n
•� ;MICHAEL E. ANDERSON r
■
EKLUTNA HEIGHTS, BLOCK I, LOT 3 .•ii/�. No. LE-4381 ti�
LEGAL DESCRIPTION: ►► �,7-�7..." g'
PERFORMED FOR: TROY DAVIS HOMES. INC. ►4(eal E t ���
DATE: 3/27/17 PROJECT No.: lhlivintrk
PARCEL ID#: TECHNICIAN: J. MILLETTE PrufessiunalEngineers Sum p
DEPTH TEST HOLE No. 2
(feet)
SLOPE SITE PLAN
1 ,V ��/, OB/OG
t` GRAVEL W/SAND
=..i`" :=:� SEE SITE PLAN h,
5 -:r>' ;. Yr. AND SILT
!:= '3
b ,
',..:*.Z..';&:,;,,,
';"'} '4 GM
8I;.ym
~
:..s�-t::9 i
1!Y,
`.,..m•.::;'•" WAS GROUND WATER ENCOUNTERED? l
10 .:
''fc.:;:;r;, IF YES @ WHAT DEPTH''
;?':'.:44;: ' DEPTH TO WATER AFTER MONITORING: NONE
11 t5:Y:: DA-IE OF MONITORING: 4/6/17
.k.V-;: DEPTH OF
c-,,...-..,..>'..,.:3-•, DATE READING GROSS TIME NET TIME WATER NET DROP
13 .;r:1.';-:'}''' (MINUTES) (MINUTES) (INCHES)
}::.4i:',;t, (INCHES)
14 °�' 'r'. :': 3/27 TEST HOLE PRESOAKED PRIOR TO TESTING:
i1,1r+ �+
15 '"` A: ;
. °• I 1:09 6.00°
4'i"°:'`
16 'ti BOH @ 16' 2 1:37 28 DRY 6.00"
3 1:40 6.00"
17— 4 2:09 29 DRY 6.00"
18— 5 2:10
6.00"
19 6 2:39 29 DRY 6.00"
20
PERCOLATION RATE:4.8 (MIN/INCH) PERC. HOLE DIA. 6" (INCHES)
TEST RUN BETWEEN FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
TEST PERFORMED BY ANDERSON ENGINEERING. 1,MICHAEL E. ANDERSON CERTIFY THAT
THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS
DATE: 4/7/17
MUNICIPALITY OF ANCHORAGE � ,1,+
DEVELOPMENT SERVICES DEPARTMENT 4•" .4214
4700 BRAGAW STREET ANCHORAGE, AK 99519-6650
SOILS LOG - PERCOLATION TEST %
B• enj in Schiller ••���0"
LEGAL DESCRIPTION: EKLUTNA HEIGHTS, BLOCK I, LOT 3 ��`�`�isr. CE12p.•• •
•'.��
t�`F�f�PROFESSIONP��.�'�
PERFORMED FOR: TROY DAVIS HOMES. INC. \tR,`���
DATE: 3/27/17 PROJECT No.:
PARCEL ID#: TECHNICIAN: J. M I L LE T T E Profen ional En_ineers Stam.:
DEPTH TEST HOLE No. 2
(feet)
1
SLOPE SITE PLAN
2
/4 OB/OG
1.,:,:::-.,2--p----
3
..▪-.::.....h.....,,--;...t,:-p- i
3 =- �= '-_.<
...,,,,:::%:,,,, 7,��' GRAVEL W/SAND
5 T,c�._`,- AND SILT SEE SITE PLAN Si
6 s1� 1
_,.:
7 • ;--
GM
g .i.r.,y=::�x
9 r''i:..,ip:•:
—~..,..,. .-:-T:"...4' WAS GROUND WATER ENCOUNTERED? No
10 :...:
`...:} ,r:r': IF YES L WHAT DEPTH''
'.,:y 4>T•!: DEPTH TO WATER AFTER MONITORING: 1L•
1 I i▪ +:* a:= ^ DATE OF MONITORING: 5/15/17
12 't_' ..-z`_'. : DEPTH OF
,`,, ,:='7$F DATE READING GROSS TIME NET TIME WATER NET DROP
13 ..7''''':g;:". (MINUTES) (MINUTES) (INCHES) (INCHES)
14 .= : '.:▪: 3/27 TEST HOLE PRESOAKED PRIOR TO TESTING:
15�"y`Le,-Y I 1:09 6.00"
16 4;::.'; >:4• BOH @ 16' 2 1:37 28 DRY 6.00"
3 1:40 6.00"
17
4 2:09 29 DRY 6.00"
18 5 2:10 6.00"
19 2:39 29 DRY 6.00"
20
PERCOLATION RATE: 4.8 (MIN/INCH) PERC. HOLE DIA. 6" (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: TEST HOLE PRE SOAKED PRIOR TO TEST.
ON-SITE WASTEWATER DISPOSAL SYSTEM
CONSTRUCTION AND MATERIAL SPECIFICATIONS
SUBJECT: LOT 3, BLOCK 1, EKLUTNA HEIGHTS SUBDIVISION
GENERAL:
1. The scope of this project includes the procurement and placement of a new
1,250-gallon septic tank at the location shown on the Site Plan. Work also
includes the construction of a new 54' long X 3' wide X 7' effective depth
absorption trench at the location also shown on the Site Plan. The
distribution line in the trench will be placed at 4.0' below the existing ground
surface. Total depth of the trench will be 11' below the existing ground
surface. The new absorption trench and septic tank must be placed a
minimum of 100' from all private wells and any surface water in the area and
10' from the water service line proposed for the lot. A minimum of 3' of cover
is required over the absorption trench and 4' of cover over the septic tank.
2. Construction shall be in accordance with the approved site plan, design
drawings, Municipal Permit with any special provisions or conditions, and all
applicable State and Municipal Wastewater Disposal Regulations.
3. The Contractor shall be responsible for obtaining all underground utility
locates and for the layout of the septic system and verification of the location
of all lot lines. The Contractor must also verify the location of wells in the
area and assure that the separation distances are met.
4. Unless specifically agreed otherwise, the contractor shall be responsible for
final grading areas subsequently depressed from soil settling. Property
owner shall be responsible for revegetation of affected areas unless
specifically agreed otherwise.
5. Contractors installing wastewater disposal systems must be certified by the
Municipal Building Safety Division On-Site Water and Wastewater Program
for system installations. Owners installing their own systems must receive
prior approval from the On-Site Water and Wastewater Program. before
beginning system installation.
SEPTIC TANK INSTALLATION
1. A new 1,250-gallon septic tank must be procured from an approved source
and installed at the location shown.
2. A septic tank is to be constructed by a certified septic tank manufacturer.
Construction shall include two 4" cleanouts for pumping access.
Lot 3, Block 1, Eklutna Heights
April 7, 2017
Page 2 of 3
3. The septic tank shall be sufficiently bedded to prevent settling or shifting of
the tank.
4. All standpipes on the septic tank shall extend a minimum of 12 inches above
final grade.
5. Tanks installed without 4' of cover shall have a minimum of 2" of direct burial
insulation.
6. A foundation cleanout shall be installed one to four feet from the building
foundation. Two cleanouts are required between the tank and the drainfield.
7. Final grading over the tank shall be such that a positive slope exists away
from the septic tank.
DRAINFIELD CONSTRUCTION:
1. The drainfield shall be constructed to the dimensions shown on the design.
The bottom of the trench shall be within 2" of level.
2. Distribution piping must be placed level with perforations down atop a level
bed of drainfield rock. Rock should then be placed over the pipe to provide a
minimum of 2" of cover.
3. A silt barrier or geotextile fabric must be placed between the drainfield rock
and the natural soil backfill.
4. Monitor tubes must be 4" in diameter and installed at the locations shown on
the design. The portion below the distribution line must be perforated.
5. Contractor shall verify the septic tank and drainfield are a minimum 100' away
from any private water wells in the area, 150' from a Class "C" Well or 200'
from any community well.
6. Direct bury insulation must be placed over the distribution system if less than
3' of backfill depth is available. Finish grade over the trench must be
mounded to prevent settlement or depressions.
7. Grade area surrounding the absorption trench to drain away.
8. A minimum 2' of accepting soil is required below the drainfield rock for a 5'
wide trench. All pockets of unacceptable materials must be removed and
replaced.
Lot 3, Block 1, Eklutna Heights
April 7, 2017
Page 3 of 3
MATERIAL SPECIFICATIONS:
1. Septic tanks must be constructed by a municipally approved septic tank
manufacturer.
2. The following pipe materials are approved for use in septic system
installations in the Municipality of Anchorage:
Cast Iron (perforated and solid), ASTM D3034 or P.V.C. (perforated and
solid), ASTM F810 or H.D.P.E. (perforated, but not solid) and ASTM D2662
or A.B.S. (perforated and solid).
3. Insulation shall be at least 2" thick extruded direct burial polystyrene (Dow
Chemical Co. Styrofoam HI or equal).
4. Septic tank inlets and outlets shall be fitted with watertight couplings
(Caulder, Fernco, or equal).
5. A permeable geotextile fabric (Typar, Mirafi or equal) must be installed
between the final drain rock layer and the native soil layer.
6. All drain rock shall be .5" to 2.5" in diameter with less than 3% passing the
#200 sieve.
INSPECTIONS:
Municipal Ordinance requires a minimum of two inspections. These inspections
must be conducted under the supervision of a professional engineer registered
in the State of Alaska. The first inspection must be conducted after the
excavation of trenches, beds or pits and before the installation of any gravel. A
septic tank may be set in place, but may not be backfilled.
The second inspection must be conducted after the placement of the geotextile
fabric, gravel, distribution piping, standpipes, cleanouts and insulation. No
backfill should be in place at the time of inspection.
Contractor shall provide a copy of all field survey layout and construction notes
for use in preparing the certified as-built of the completed system.
,yeti n.
(f A A
/ ,
OPINION OF COMPLIANCE
ANCHORAGE GENERAL PERMIT 93-10-M4/11-M4/12-M4
File Number: POA-2017-171
Municipal Reference Number: Peters Creek 17-A
Permittee (LANDOWNER): Troy Davis Homes
Expiration Date: October 31, 2020
Project Location: Eklutna Heights Sub, Block 1, Lot 3, Chugiak
Anchorage Wetland
Management Plan Map #: 25
Wetland Unit #: 113
Wetlands Fill Amounts: 600 sq ft; -5 cyds backfill
Work Description: Excavation and backfill for septic connection to new home.
All work will be performed in accordance with the attached plans submitted
with application dated: April 14, 2017
The permittee will perform work in waters of the U.S. (wetlands) in accordance
with the terms and conditions of the Anchorage General Permit, as specified
below:
Anchorage General Permit Conditions:
ORAL CONDITIONS OF THESE GENERAL PERMITS
All activities identified and authorized by these GPs shall be consistent with the special
conditions listed above, as well as the general conditions listed below.The Corps can also
add site-specific special conditions to a GP verification,as applicable.
Obtain GP verification prior to activity: No work shall be done under these GPs without first
obtaining an Opinion of Compliance(OC)from the MOA Planning Division or General Permit
Verification from the Corps.A copy of the Municipal building permit application and grade/fill
permit application or Land Use permit application must be included with the GP application.
Compensatory mitigation, if required, must be acquired before proceeding with authorized
jurisdictional activities.
Time limit: Verification under these GPs is valid until October 31,2020, unless the GPs are
modified, reissued or revoked. It is incumbent upon the applicant to remain informed of
changes to the GPs.
Troy Davis Homes 1
POA-2017-171; Peters Creek 17-A
transaction.All information must be submitted within 30 days of the property transfer to
validate the transfer of the GP authorization to the new party.
Modification by other authorization: If the work proposed under these GPs is subsequently
modified by any other Federal, State,or local governmental authorization, a modification of the
GPs, MOA Planning Division's Opinion of Compliance, and any verification by the Corps to
perform activities under these GPs may need to be obtained.
Use of multiple general permits,including Nationwide Permits:The use of more than one GP or
Nationwide Permit (NW P) for a single and complete project is prohibited, except when the
acreage loss of waters of the United States authorized by the GPs and/or NW Ps does not
exceed the loss of more than one acre of wetlands.
Project site restrictions and design criteria:
1. For residential developments, the aggregate total loss of waters of the United States
authorized byGP-1993-10-M4 shall not exceed one acre. For residential
subdivisions,the aggregate total loss of waters of United States authorized by this GP
cannot exceed one acre.This includes any loss of waters of the United States
associated with development of individual subdivision lots.
2. Erosion Control: Prior to the initiation of any fill discharge authorized in accordance
with GP- 1993-10-M4, the Permittee shall install erosion control measures along the
perimeter of all work areas to prevent the displacement or erosion of fill material
outside the authorized work areas. The erosion control measures shall remain in
place and be maintained until all authorized work is completed and the work areas
are stabilized. Immediately after completion of the final grading of the land surface,
all slopes, land surfaces, and filled areas shall be stabilized using sod, degradable
mats, barriers, or a combination of similar stabilizing materials to prevent erosion.
3. Fill Material: Only clean fill material shall be used for this project.The fill
material shall be free from items such as trash, debris, automotive parts, asphalt,
construction materials, concrete blocks with exposed reinforcement bars, and soils
contaminated with any toxic substance, in toxic amounts in accordance with
Section 307 of the Clean Water Act.
4 Within 60 days of completion of the work authorized by this permit,the Permittee shall
complete EITHER the attached"Self-Certification Statement of Compliance"form
(Attachment D),Q$the attached"As-Built Certification By Professional Engineer"form
(Attachment E),and submit it to the Corps. These are further described below.
Self-Certification Statement of Compliance: In the event that the completed work
deviates in any manner from the authorized work, the Permittee shall describe the
deviations between the work authorized by this permit and the work as constructed on
the"Self-Certification Statement of Compliance"form. The description of any
deviations on the"Self-Certification Statement of Compliance"form does not
constitute approval of any deviations by the Corps.
As-Built Certification: Within 60 days of completion of the work authorized by this
permit, the Permittee shall submit as-built drawings of the authorized work and a
completed"As-Built Certification By Professional Engineer"form to the Corps.The as-
built drawings shall be signed and sealed by a registered professional engineer and
include the following:
a. A plan view drawing of the location of the authorized work footprint, as shown on
the permit drawings,with transparent overlay of the work as constructed in the
same scale as the permit drawings on 81/2-inch by 11-inch sheets or PDF. The
plan view drawing should show all "earth disturbance,"including wetland impacts
and water management structures.
Troy Davis Homes 3
POA-2017-171; Peters Creek 17-A
4. Offset Unavoidable Impacts. To offset the unavoidable adverse impacts of the project to the
aquatic environment, the permitee:
® Mitigation not required; fill less than 0.1 acres.
5. Limits on Work Area. You must not conduct any of the following activities in wetlands or
waterbodies beyond the approved project footprint(or in any other avoidance area identified above)
during either construction or operation of the project/facility:
D Discharge of fill material(even temporarily), including stockpiles;or,
D Excavation and sidecasting/backfilling;or,
D Mechanized landclearing;or,
D Operation, parking/storage or servicing of equipment.
6. Construction Runoff. You must employ runoff control measures necessary to preclude or
minimize both erosion and the transport of sediment, pollutants,and solid waste beyond the
approved project footprint. These measures shall include, but are not limited to:
❑ Phasing of Site Preparation(to minimize the extent of exposed soil);
❑ Silt Fence;
❑ Reroute Offsite Runoff around Disturbed Soils(e.g.,dike/ditch)
El Mulching (e.g.,wood chips,straw, grass clippings,gravel);
❑ Matting(e.g.,jute,straw,coir);
❑ Sheeting for Stockpiles,Temporarily Exposed Slopes (e.g., plastic, geotextile fabric);
❑ Check Dams in Ditches/Drainageways(e.g., hay bales,sand bags,gravel berms);
❑ Surface Roughening(to slow runoff down slope);
O Terracing of Slopes;
❑ Sediment Trap(s);
❑ Temporary Sediment Basin;
❑ Storm Drain Inlet Protection (e.g., hay bales,sand bags, and gravel berm)
❑ Outlet Filtering/Stabilization for Construction Dewatering;
• Revegetation of Fills and Disturbed Soils—basic regrade and seeding
❑ Onsite petroleum spill/leak response equipment and supplies and provision for their
proper disposal
7. Contaminated Soil. If contaminated soils are discovered during construction, you must
immediately cease all work in the vicinity of the contamination,contact the Alaska Department of
Environmental Conservation for instructions,and defer any further activity until you receive ADEC
approval to continue.
8. Endangered Species. The activity must not jeopardize the continued existence of a threatened or
endangered species,as identified under the Endangered Species Act,nor endanger the critical
habitat of such species.
Troy Davis Homes 5
POA-2017-171; Peters Creek 1'1-A
When the work authorized by the Anchorage General Permit is still in existence at the time the
property is transferred the terms and conditions of the permit will continue to be binding on the
new owner(s) of the property. To validate the transfer of the permit and the associated liabilities
associated with compliance with its terms and conditions have the transferee sign and date
below.
(TRANSFEREE) (DATE)
Attachments: Final Project Plans (sheets , dated )
Troy Davis Homes 7
POA-2017-171; Peters Creek 17-A
•
G`- ao
•� .� Municipality of Anchorage
On-Site Water and Wastewater Program
(907) 343-7904 SAFETY
Certificate of On-Site Systems Approval 1
Parcel I.D. 051-062-03 Expiration Date: `f `a c I c/
1. GENERAL INFORMATION
Complete legal description Eklutna Heights Block 1 Lot 3
Location (site address) 24244 Mount Eklutna Dr
Current Property owner(s) Troy Davis Homes Day phone 907-357-9394
Mailing address 1689 S Knik Goose Bay Rd #400 Wasilla, AK
Real Estate Agent Day phone
2. TYPE OF DWELLING:
E Single Family (w/wo ADU)
❑ Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS:
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well Q Individual
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System ❑ Public Sewer ❑
WaiverNariance request for: Distance:
Received by: 0/10141.A474/-'0711.) Date: 00//i
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ 111 . 68 Waiver Fee $
Date of Payment I a l 1 b 111 Date of Payment
Receipt Number 0 3 `otC'1 Receipt Number
COSA# O C 11 1 L Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Forge Engineering Phone 907-522-7773
Address 1399 W. 34th Ave. Suite 203 Anchorage, AK 99503
Engineer's Printed Name Benjamin Schiller Date 12/20/17
IMP''C�•••' .c4 }
A' C#1
y}#
6. DSD SIGNATURE /
System #1 Approved for bedrooms
Y pp � �..•Ben'';a n Schiller :
System #2 Approved for bedrooms %` c- 12592 Stqtt 4i
Disapproved
Conditional approval for bedrooms, with the following stipulations:
...OYOFilk,tiU
.# ON-SITE ; .:
WATER AND
o WASTEWATER• o
PROGRAM
"Sir SPITE `:
=y: �,,—�— / Original Certificate Date: / 02 C — (
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS:
COSA Checklist X Nitrate Advisory
Septic System Advisory Arsenic Advisory
Well Flow Advisory Other
COSA blue sheet£ c
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Certificate of On-Site Systems Approval Checklist
Legal Description: Eklutna Heights Block 1 Lot 3 Parcel ID: 051-062-03
A. WELL DATA
Well type Private If A, B, or C provide PWSID# Well Log (Y/N) N
Date completed Unknown Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y
Total depth ft. Cased to ft. Casing height(above ground) 24 in.
FROM WELL LOG AT INSPECTION
Date of test Unknown 3/15/17
Static water level ft. 48.8 ft.
Well production g.p.m. 1 g.p.m.
WATER SAMPLE RESULTS:
Coliform ND colonies/100 mL Nitrate 4.28 mg/L
Arsenic N ug/L Date of sample: 11/6/17 Wheaton Water Wells
Collected by:
B. SEPTIC/HOLDING TANK DATA
Tank Type/Material Septic/Steel Date installed 8/04/17
Tank size 1 000 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping Pumper New Construction
C. ABSORPTION FIELD DATA
Date installed 8/03/17 Soil rating (g.p.d./ft2 or ft2/bdrm) 0.8 System type Deep Trench
Length 47 ft. Width 3 0 ft. Gravel below pipe 6.0 ft.
Total depth 9.7 ft. Eff. absorption area 564 ft2 Monitoring tube Y Depression over field N
Date of adequacy test New Const. Results (Pass/Fail) For bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d.
Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off' level at in. High water alarm level at in.
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100' On adjacent lots >100'
Absorption field on lot >100' On adjacent lots >100'
Public sewer main >75' Public sewer manhole/cleanout >100'
Sewer/septic service line >25' Holding tank >75'
Animal containment areas >50' Manure/animal excrete storage areas >100'
SEPTIC/HOLDING TANK ON LOT TO:
>5' >5' >5'
Building foundation Property line Absorption field
Water main >1 Water service line > Surface water >100
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line >10Building foundation >10 Water main >10
10'
Water Service line > Surface water > Driveway, parking/vehicle storage >
Curtain drain None Noted Wells on adjacent lots >100'
F. COMMENTS
G. ENGINEER'S CERTIFICATION ..-.►-NOIN\\
1 certify that I have determined through field inspections and ..!,`Q.•••' t�review of Municipal records that the above systems are in meg••' y fconformance with MOA COSA guidelines in effect on this date. %*: • ' lli *9'f'
•-.*�/
Engineer's Printed Name Benjamin Schiller •.••�.- �
Date
1 2/20/1 7 / Benia 1 Schiller .• i
� ':'•. C 15.92 �41:10
COSA brown sheet 10-10-12.doc
,.``
MOUNT EKLUTNA DRIVE
N 89'55'10"E 165.11'
_ x x \x�
/ ••:.; - . L\_ 33' ROADWAY
J • >t>1.. EASEMENT
_„ \
WOODEN FENCE 24.9 \
b a D \
5.9 6a 7 cv N t.o' 83.5'
/ 29.2' 4 '
010.7 1
J o 1 STORY RESIDENCE N CHAIN—LINK FENCE
I N w/ WALKOUT BSMT. M WELL I
27.2' b21.0' „
I w 0 N I
1 Z 1.5'x4.2' CANT of <n
x 0 /o o
\ tin SEPTIC PIPES cvo /
Lot 4 o m WEST 1/2 Lot 2
Q.
6 \ o Lot 3
N
co
\ / 54,476 s.f. co
4. ct /
N 7
Eig\__ .--
CHAIN—LINK FENCE
12.2'x16.2' SHED
SEPTIC PIPES
33' ROADWAY EASEMENT
)
S 89'55'10"W 165.11'
MIRROR DRIVE
—1 r_ ____ ____ _
I I
Lot 6
I I