Loading...
HomeMy WebLinkAboutARGYLE LT 2Municipality of Anchorage On -Site Water and Wastewater Program • (907) 343-7904 Page of ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171186 PID Number: 015-141-19 Dwelling: ❑■ Single Family (SF) ❑ Duplex (D) ❑ Multiple (SF and/or D) Project: ❑■ New ❑ Upgrade Name: The Dittrich Company ABSORPTION FIELD ❑ Deep Trench ❑■ Shallow Trench ❑ Bed ❑ Mound Address PO Box 90411, Anchorage, AK 99509 ❑ Other Phone Number of Bedrooms Soil Rating depth from original grade 907-357-9394 1 4 1.2 GPD/SF JTotal 9.3 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5.3 Ft. Gravel depth beneath pipe 4 Ft. Subdivision Block Lot Argyle 2 Fill added above original grade 0 Ft. Gravel length 50 Ft. Township Range Section Gravel width 5 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES To Septic Absorption Lift Station Holding Sewer Total absorption area Number of trenches Dist. between trenches From Tank Field Tank Line 500 Ft 1 Ft. Well >100' >100' N/A N/A >25' TANK ❑■ Septic ❑ S.T.E.P. ❑ Holding ❑ Other Manufacturer Anchorage Tank Capacity 11,250 Gal. Surface Water >100' >100' N/A NIA Material Number of compartments Lot Line >5' >10' N/A N/A Steel Two NA Foundation >5' >10' N/A N/A LIFT STATION Manufacturer Capacity Gal. Curtain Drain None Noted Remarks Pump on level at in. Pump off level at in. High water alarm at in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank D3034 Tank to drainfield D3034 Installer Glacier Masonry Drainfield D3034 CO/MT 3034 Inspector MEA BENCHMARK (Assumed elevation) 100.0 ft Inspdection 15� 8/23/17 8/24/17 Location and description 2nd 3rd 4th Bottom of siding. COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp �•.��,.. F A4 kit Conditional Approval: Date o •• 70, 49TH r* 491H- ................. e ... ... .i �.�..._.�.�.:� %.................1 r- •MICHAEL E. ANDERSON 0 CE -4381 ® ��('.r.� �y 5b 1/110 '••....... ®14%►re®a Approved l' Date ®s®®' Inspection Report_9-1-12.doc PE VA ARGYLE LOT 2 ,RMIT # OSP171186 PID # 015-141-19 I LOT 1 50LFx5'x4'EFF i SEPTIC TRENCH 1250 -GAL SEPTIC TANK I I I I I I I A.C. DRIVE I I I v i I Ld m WI I Iii N I O I 4-BDRM DOME I O_F ALTERNATE SITE I MT1 C01 r I I I I I •. I II • ;V2 i TH1 I 2C •. I I i I Z I I ]VI 14, L� • • . ••CO2 O j N WELL / TH#2 I i i / •• I LOT 2 A B LOT 3 \� I FCO 3.0 15.6 SV1 6.0 18.0 SV2 16.8 22.8 2CO 22.8 27.0 C01 37.2 50.1 MT1 38.1 51.0 CO2 37.2 27.6 MT2 37.8 1 27.9 \ NOTE: / NO SLOPES >25% WITHIN 50' OR SURFACE WATER WITHIN 100' OF THE LEGEND l� PROPOSED SEPTIC SYSTEM CO - CLEANOUT `meq TM *'0 ALL WELLS ON SURROUNDING LOTS WITH IMPACTS TO THIS 2CO - DOUBLE CLEANOUT PROPERTY ARE SHOWN. NO CONFLICTS WITH WELLS OR SEPTIC FCO -FOUNDATION CLEAN( `.`.�"h SYSTEMS. FS - FLOW SPLITTER VALVE '. Michael E. Anderson : • •/ MH - MANHOLE I �F�� .•1 CE 4381 0 50 100 MT -MONITORING TUBE fl srF�•:;�` �,•���w FEET 1 ROFESSIONPSV - SEPTIC VENT 1 -50 TH - TEST HOLE ARGYLE LOT 2 PERMIT # OSP171186 PID # 015-141-19 N O LL C) CV 98.7 93.2 -------------------- 93.0 92.3 92.6 1250 GAL 92.4 SEPTIC TANK 88.3 97.5 ORIGINAL AND FINAL GRADE 92.2 92.2 88.2 50, 88.2 NOTE: MT1 HAD 6" OF DEBRIS AT THE BOTTOM AFTER CONSTRUCTION —81.5 = NO GROUNDWATER 7/16/17 H �eslll *.•STM ••*rl I '. Michael E. Anderson PROFILE AS -BUILT l �F•'• CE 4381 •`�% (NO SCALE) �t�ilF9F�PROFESS pOO'�,o��s ow as•nIi M -W brilling, Inc. oP.O. Box 110389,s, Anchorage, AK 99511* 907-345-4000 * 907-345-3287 Faxis Well Owner: Dittrich Co, LLC Use of Well: Domestic Legal Description: Argyfe Subdivision Lot 2 Anchorage, AK CONSTRUnI ON Drift Method: 'Air Rotary Hole Size: 6- Hole Depth: 26" Casing Size: 6- Cased to: 261'—, Material: —A53B Wall: —.250 Well Completion: Open —end X Screen Screen/Perforation description: n/a Grout Notes: 2 ) Sack(s) of Bentonite Well Development: Air Surge Well Disinfected: ffo-- Method: Yield test at 20 GPM for .5 hour(s) with 100% of drawdown (DD) from static level(SWL). Method: Air s—urge —Static Water Level (SWL): 219' Start Date: 8/28/2017 — Completion Date: 9/1/2017 Test Pump Date: n/a Final Pump Install Date: --E/—a MUNICIPALITY OF ANCHORAGE -_e Development Services Department Phone: 907-343-7904 On -Site Water & Wastewater Section Fax: 907-343-7997 Pump Installation Log Well Drilling Permit Nuinber: 05P171186 Date of Issue: - - Parcel Identification Number. 015-141-19 Legal Description Block Lot Property Owner Name & Address: Argyle Subdivision 2 John & Marium Claire 10841 Lipscomb Street Pump Installation Date: 9 - 6 -2017 Pump Intake Depth Below Top of Well Casing: 252 Pump Manufacturer's Name: Grundfos Pump Model: SQE-330 IPump Size: 1 hp feet Pitless Adapter Burial Depth: 10 feet Pitless Adapter Manufacturer's Name: Martinson M -B10 Pitless Adapter Installer: Trevor Tillinghast Well Disinfected Upon Completion? EK Yes ❑ No Method of Disinfection: clorox bleach Comments: Pump Installer Name: Trevor Tillinghast Company: M -W Drilling, Inc. Mailing Address: PO Box 110389 City: Anchorage State: AK Zip: 99511 Attention: The pump installer shall provide a pump installation log to On-site Nvithui 30 days of pump installation. � � N Wa_ O O r+7 N 'p o 1n -n C OD Q, _ � ® < I o m m ! -a v n LZ -)g C O \ D m Cp v ;o z N 4N r r N .0k to N 0 rn N c V m rn rn Nr2Z 0rn-rZZ1 c)O; Z Oram o 05 r Z y Z 2 a; �) --I ® r1 O m �Nrn n��rn'o z'o !o7 m Opa �rtZ N 4 O Z-nwmNuAf Xp= m Q DZZ ®�r�*1r U) Z c�0c)04 �r,o- en O ®ZV1®®m0OX m p '° �0NN® Zeo�� ,? D�ocn _ m—ir—vf7OVj--iC cn ZZQO= zo p m0� 08'rn ®® m Vf®D �OZorn 2 A a -i N m co C N r 0 m rel) o o m V, II r LIPSC®MB STREET W W N 00003'10,,w 150.00' 10' ITIL. ESMT_ 25' BUILDING SETBACK LINE � N A A gym`, r O :V m 35.8' co X 35.7' r cn O ZZ c7 � V) ° 't7 ° \ .• C7 V) p` \ N \ g 0� \ FA \ C� \ N 00`03'30"W 150.00' to 0 0 0 0 m N to V S 6a a)a,•••• •%f S ��� ••• 1• P ° • `� • All • s p ••°. p • O!\ p� • • i1 N adv • • • Allf % s • -.40• • 4w •••® co C N r 0 m rel) o o m V, II r LIPSC®MB STREET W W N 00003'10,,w 150.00' 10' ITIL. ESMT_ 25' BUILDING SETBACK LINE � N A A gym`, r O :V m 35.8' co X 35.7' r cn O ZZ c7 � V) ° 't7 ° \ .• C7 V) p` \ N \ g 0� \ FA \ C� \ N 00`03'30"W 150.00' to 0 0 0 0 m N to V MUNICIPALITY OF ANCHORAGE On-Site Water&Wastewater Program ♦° S PO Box 196650 4700 Elmore Road Anchorage,Alaska 99519-6650 Phone (907)343-7904 Fax: (907)343-7997 „ t';- http//www.muni.org/onsite '�a' r epartment 4 CHn° �t On-Site Water & Wastewater System Permit Permit Number: OSP171186 Effective Date: 7/25/2017 Work Type: WellSeptic Initial Expiration Date: 7/25/2018 Tax Code Number: 01514119000 Site Legal Address: ARGYLE LT 2 G:2636 Site Mailing Address: 10841 Lipscomb ST, Anchorage Owner: DITTRICH COMPANY LLC Lot Size in Sq Ft: 44516 Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 4 This permit is for the construction of: II Disposal Field 0 Septic Tank ❑ Holding Tank 0 Privy El Private Well 0 Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72)and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: V&1 /441)(4'C Date: 1/2-6// Issued By: Viji<t(1 A l Date: 7/2 5/2o I MUNICIPALITY OF ANCHORAGE „L") Community Development Department Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 015-141-19 Property owner(s) The Dittrich Company, LLC Day phone Mailing address P.O. Box 90411 Anchorage, AK 99509 Site address NHN Lipscomb Street Anchorage, AK 99516 Legal description (Sub'd., Block & Lot) Argyle, Lot 2 Legal description (Township, Range & Section) Lot Size 44,516 Sq. Ft. Number of Bedrooms Four (4) APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field 0 Initial Single Family (SF) (w/wo ADU) Septic Tank Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE /WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. 74-tasti E 64„,12 -) (Signature of property owner or authorized agent) Permit/Rush Fees: '914 Waiver Fees: Date of Payment: -t11.3-11?" Date of Payment: Receipt Number: �y Receipt Number: Permit No. OS Pl 11?(o Waiver No. Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) July 16, 2017 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 South Bragaw Street Anchorage, AK 99519-6650 Subject: Lot 2, Argyle Subdivision Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of Lot 2, Argyle Subdivision intends to construct a new four-bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells and septic systems on surrounding lots. No conflicts exist between the proposed septic system and well or septic systems and wells on adjacent lots. Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. Two test holes were recently placed on the lot in the area of the absorption trench and alternate site. The logs indicate silty sand (SW/SM) with gravel in the zone specified for the absorption trench. The percolation rate of the soil was determined to be 3-5 minutes per inch. No groundwater was found during the placement of the test holes and none developed during the monitoring period. An application rate of 1 .2 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1,250-gallon septic tank and a 50' long by 5' wide by 4' effective depth absorption trench to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 3' below the surface and the total depth will be 7'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption trench and 4' over the septic tank. The ground surface on the lot in the area of the septic system slopes to the west at a slight grade. The new trench will be constructed parallel with the contours of the slope as much as possible in conformance with Municipal requirements. The new septic Lot 2, Argyle Subdivision July 16, 2017 Page Two system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. Sincerely, '114c-d/J- Michael E. Anderson, P.E. Attachments 4. 4-c ftlJII * ,MICHAEL E. ANDERSON it!:, 40,0�il' No. CE-43B1 OMALLEY ROAD wee LOT 1 LOT 11A No Conflicts with Well or Septic System on this Lot. Wl I— I I rM'/1 l l l A.C.owe r , V l J CO I I S)I o � U I o- LOT 11B \ "( VACANT I ~\ 1.10 LOT 3 I I LOT 2 ..•••••*�� �FOF ARGYLE SUBDIVISION • • ,q _,�P.•• qs ,,` • 44,517 SF '* 4911-1. ••7 vI + f ',MICHAEL E. ANDERSON REA MAP CE-4381 SCALE 1' = 100' 1I 'PeQ,?� i6 '� .•�,``� LOT 2 ARGYLE SUBDIVISION 412' - __. -- 44,517 SF 412' `-'--N 90'00'00"E 296.77' / / re FCO Alternate W A.C. DRIVE Four Bedroom =5 s o ® Site W0 Home TH1 IXz 41 m o 0 I- 0 w w co o N o- — ' r z Proposed Well ^' -57. C113 . 5 J —1 3 L 0 n O � 0 p "' O O O U o `'J TH2 ® o (/) z NOTE: 2 C , / No Areas of Excessive Slope or Surface / J \ Water are Within 100' of Any Part of the New Septic System. No Wells or Wastewater Systems on Adjacent Lots Conflict with the \ Proposed Septic System. I I N 90'00'004 0 296.77' Ciai 410' - 44.474 LEGEND j ' \ �� i _ 49th MT — Monitor Tube 0• 114:41..d. A MH — Man Hole , FCO — Foundation Clean Out SITE P A \ ,,;MICHAEL E. ANDERSON ; ` TH — Test Hole ♦C • :. 'm CO — Clean Out •♦✓�, No. CE-4381 • ti • FSV — Flow Splitter Valve SCALE 1' = 40' �••��,�,'•.,7-((,-i.,.•°��'V• 2C0 — Double Clean Out ♦I N,;ROFESSZzti4. LOT 2, ARGYLE SUBDIVISION DESIGN FACTORS: SYSTEM REQUIREMENTS: Four Bedroom Home 5' Wide Trench System Perc. Rate: 1-5 Min./Inch 1,250 Gallon Septic Tank Application Rate: 1.2 GPD/SF 4' Drainfield Rock 4 Bedrooms * 150 GPD/Bedroom = 600 GPD Design Flow 600 GPD/1.2 GPD/SF/5 SF (Width) *.5 (Red. Factor)= 50 LF Trench Length THEREFORE: Construct a 50' Long x 5' Wide x 4' Effective Depth Absorption Trench. Flow Line Elevation in Trench to be 3' Below Original Ground Surface. Total Depth to be 7' Below Existing Ground. Provide 3' Cover Over Absorption Trench and 4' Cover Over Septic Tank. 2'6" eotextile Fabric 6" O 4" Perforated PVC (Holes Down) 4' Drainfield Rock 5' I I TYPICAL 5' WIDE TRENCH SECTION ,..•---�>,.�� (NO SCALE) � CE ...., 1111 11 NOTE: Grade Area Over Trench to Drain Away. Minimum 6' Separation From Bedrock. 49th Minimum 4' Separation From Groundwater. o Minimum 100'Separation From Private Wells in the Area. �� MICHAEL E ANDERSON i LC.5: Minimum 100' Separation From Surface Water or Streams. ;1 s:, N . cE- 4 '�.... 7-rG..t.7"k.�.• 11111pa::S:: ,6.. MUNICIPALITY OF ANCHORAGE .'sir ani , DEVELOPMENT SERVICES DEPARTMENT r���- .•• •'••• Sit*. 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 '•,.... � ii 49th SOILS LOG - PERCOLATION TEST ( 41z ..Ir. -i ,'.MICHAEL E. ANDERSON•:gr LOT 2, ARGYLE SUBDIVISION IN No. CE-4381 ti C LEGAL DESCRIPTION: i. '....7-ii, 4 7 , PERFORMED FOR: JAMIE DITTRICH 94 • DATE: 6/30/17 PROJECT No.: �1� 5 • Professional Engineers Stamp: PARCEL ID#: TECHNICIAN: MEA DEPTH TEST HOLE 1 (feet) I OB/OG SLO` SITE PLAN . a - v z 4 -I — v . 5 SILTY SAND o�N SEE SITE PLAN G . G WITH GRAVEL 1 6 .4 SW/SM 7 ' 4. ' 4.A A 8 a ..L 9 . . G Ad. 1 0 WAS GROUND WATER ENCOUNTERED? No IF YES @ WHAT DEPTH.' DEPTH OF WATER AFTER MONITORING: NONE L 2%/O 11 ' DATE OF MONITORING: 7/16/17 . 4 4 12—. GROSS TIME NET TIME DEPTH TO NET DROP 13— e• Q.. ° • DATE READING (MINUTES) (MINUTES) WATER (INCHES) n (INCHES) 14 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 c °. 7/ I 10:14 0.75" 16 BOH @ 16' 2 10:34 30 9.50" 8.75' 3 10:35 1.00" 17 4 11:05 30 9.75" 8.75" 18 5 11:06 0.75" 19 6 11:36 30 9.50" 8.75" 20 PERCOLATION RATE: 3.4 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST CAVITY PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I, MICHAEL E.ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/16/17 MUNICIPALITY OF ANCHORAGE .ii.►►rrri4i DEVELOPMENT SERVICES DEPARTMENT p�••P�- ..44x C+17 4700 BRAGAW STREET ANCHORAGE, AK 99519-6650 i .. 49th =*0of SOILS LOG - PERCOLATION TEST 70 ',,,///��� T ;MICHAEL E. ANDERSEN S LOT 2, ARGYLE SUBDIVISION *V No. CE-4391 LEGAL DESCRIPTION: • PERFORMED FOR: JAMIE DITTRICH •�*11li �S'i' �a`~` DATE: 6/30/17 PROJECT No.: ����m�+� PARCEL ID#: TECHNICIAN: MEA Professional Engineers Scamp: DEPTH TEST HOLE 2 (feet) OB/OG SLOPE SITE PLAN 1 d 2 ° 3 4 5- SILTY SAND ti o SEE SITE PLAN • ° WITH GRAVEL z 6 :a . SW/SM 7a. °a e 8 —..a...a •:4 9 —.-.Q. . WAS GROUND WATER ENCOUNTERED? NO 10 .7' IF YES tri WHAT DEPTH'? DEPTH OF WATER AFTER MONITORING: 14' L 2% 11— ' '- e DATE OF MONITORING: 7/16/17 . d 12 .' . GROSS TIME NET TIME DEPTHATo NET DROP 13 d a 'a DATE READING (MINUTES) (MINUTES) WATER (INCHES) (INCHES) 14 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 d a 7/I I 10:20 .50" 16 BOH @ Ib' 2 10:50 30 8.75" 7.25" 3 10:51 _ .25" 17 4 11:21 30 8.50" 7.25" 18 F. 11:22 1.25" 19 6 11:52 30 8.50" 7.25" 20 - PERCOLATION RATE: 4.1 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: TEST CAVITY PRE SOAKED PRIOR TO TEST. TEST PERFORMED BY ANDERSON ENGINEERING. I,MICHAEL E. ANDERSON CERTIFY THAT THIS WAS PERFORMED IN ACCORDANCE WITH ALL STATE AND MUNICIPLE GUIDELINES IN EFFECT ON THIS DATE: 7/16/17 r 1 Olt o 618910 .77 fQ � J a.P . B` •F � Municipality of Anchor, u -.' f �(4 On-Site Water and Wastewater Prog =a ��v 1 (907) 343-7904 MAY 1 6 2p1� i S A F E Y Y ti Certificate of On-Site Systems A. g al A c'j Zi 0> 691,9 Parcel I.D. 015-141-19 Expiration Date: (\ulq 1/ gill 1. GENERAL INFORMATION Complete legal description Argyle Lot 2 Location (site address) 10841 Lipscomb St Current Property owner(s) The Dittrich Company Day phone 907-357-9394 Mailing address PO Box 90411 Anchorage AK 99509 Real Estate Agent Day phone 2. TYPE OF DWELLING: 0 Single Family (w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 4 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer El WaiverNariance request for: Distance: Received by: Li!4h ',) /fl/-24// Date: 5/a/A S COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ 1/l.&' Waiver Fee $ Date of Payment 57/1?- ti Date of Payment Receipt Number 65M51) Receipt Number COSA# &)Ca gf tog Waiver# 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, # based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, .,'"' J 41k, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate t for ttt- number of bedrooms and type of structure indicated herein. I further verify that based on the information ootai, -d from the Municipality of Anchorage files and from my investigation and inspection, the on-site water .44 s ••; and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes, Io:i :nces, and regulations in effect at the time of installation. Name of Firm Forge Engineering Phone (907) 522-7773 Address PO Box 240773 Anchorage, AK 99524 Engineer's Printed Name Michael E. Anderson, PE Date 5/15/18 OF At`\ t • S 6. DSD SIGNATURE ,*:o,49 T" 0 . JSystem #1 Approved for bedrooms � ,� 0� ..Michael E.Anderson 9F•, 43 1 E ce% System #2 Approved for bedrooms ,111���• `'r� Disapproved Conditional approval for bedrooms, with the following stipulations: pN P,N . FZ • `NPS��`NPP p QRoGR G �O�c s RA�nI r By: {9.-ibtie.0.0.. c €Q.Q Original Certificate Date: I t t <2 1) Au I The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA blue sheet r •• .. c If more than 1 septic system is on the lot: COSA Checklist# of Structure served by this system Certificate of On-Site Systems Approval Checklist Legal Description: Argyle Lot 2 Parcel ID: 015-141-19 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log (Y/N) Y Date completed 9/01/17 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 261 ft. Cased to 261 ft. Casing height (above ground) 36 in. FROM WELL LOG AT INSPECTION Date of test 9/01/17 Static water level 219 ft. ft. Well production 20 g.p.m. g.p.m. WATER SAMPLE RESULTS: Coliform N ei colonies/100 mL Nitrate ri . 3 1 mg/L Arsenic N ug/L Date of sample: 5/14/18 Collected by: Forge Engineering B. SEPTIC/HOLDING TANK DATA Tank Type/Material Steel/Septic Date installed 8/24/17 Tank size 1250 gal. Number of Compartments 2 Cleanouts (Y/N) Y Foundation cleanout (Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N Date of pumping Pumper New Construction C. ABSORPTION FIELD DATA Date installed 8/23/17 Soil rating (g.p.d./ft2 or ft2/bdrm) 1.2 GPD/SF System type 5-Wide Length 50 ft. Width 5 0 ft. Gravel below pipe 4.0 ft. Total depth 9.3 ft. Eff. absorption area 500 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Results (Pass/Fail) For bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. Any rejuvenation treatment (past 12 mo.) (Y/N & type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot >100' On adjacent lots >100' Absorption field on lot >100' On adjacent lots >100' Public sewer main >75' Public sewer manhole/cleanout >100' Sewer/septic service line >25' Holding tank >75' Animal containment areas >50' Manure/animal excrete storage areas >100' SEPTIC/HOLDING TANK ON LOT TO: >51* >5' >5' Building foundation Property line Absorption field Water main >10' Water service line >10' > Surface water Wells on adjacent lots >100' ABSORPTION FIELD ON LOT TO: >10' >10 10 > ' Property line Building foundation Water main Water Service line >10Surface water >100 Driveway, parking/vehicle storage > 0 Curtain drain None Noted Wells on adjacent lots >100' F. COMMENTS *Constructed before code changed to 10' G. ENGINEER'S CERTIFICATION �` OF q\vi\l I certify that I have determined through field inspections and P::.. 1, ,review of Municipal records that the above systems are in y49 TH ,p� *y conformance with MOA COSA guidelines in effect on this date. Michael E. Anderson, PE �74�'` eti 1it`-'�%-' Engineer's Printed Name �� Michael E.Anderson : / Date 5/15/18 0+ �F'• X381-E , •���%�f +4k (4 :• tom.itcc kk FDPROFESS\cS COSA brown sheet 10-10-12.doc