HomeMy WebLinkAboutT12N R3W SEC 33 LT 232 T12N R3W Sec . 33 Lot 232 #018 - 322 - 12 Municipality of Anchorage Community Development Department Page 1 of 2 On-Site Water and Wastewater Program 4700 Elmore St. • P.O. Box 196650 Anchorage, AK 99519-6650 • http://www.muni.org/onsite • (907)343-7904 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP181426 PID Number: 018-322-12 ❑ New ❑✓ Upgrade Name: LARRY SMITH &VIRGINIA WOLF ABSORPTION FIELD Address ❑✓ Deep Trench ❑ Shallow Trench ❑ Bed ❑ Mound 15302 OLD SEWARD HIGHWAY ❑ Other Phone Number of Bedrooms Soil Rating Total depth from original grade 3 1.2GPDISF 10.0 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade Gravel depth beneath pipe Subdivision Block Lot 4.0 Ft. 6.0 Ft. 232 Fill added above original grade Gravel length Township Range Section 0.0 Ft. 35 Ft. 12N 3W 33 Gravel width Beds:Number of Lines Distance between lines SEPARATION DISTANCES 2.5Ft. N/A N/A Ft. To Septic Absorption Holding Sewer Total absorption area Number of trenches Dist.between trenches Tank Field Lift Station Tank Line 420 2 1 From Ft N/A Ft. Well 100+ 100+ N/A N/A 100+ TANK D Septic ❑S.T.E.P. 0 Holding 0 Other Mani cfanturer Capacity Surface Water 100+ 100+ N/A N/A . +.t tl'f Na-c by' 1000Gal. Material Number of compartments Lot Line 5+ 10+ N/A N/A PLASTIC 2 NA Foundation 10+ 10+ N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain 50+ 50+ N/A N/A Gal. Pump on level at Pump off level at High water alarm at Remarks in. in. in. Pump make and model Electrical Inspections performed by PIPE MATERIAL House to tank3034 Tank to Installer drainfield 3034 WILCO Drainfield 3034 CO/MT 3034 Inspector Pannone Engineering Services BENCH MARK (Assumed elevation) 100.0 ft Inspection 1st 1/23/19 and description dates: 1123119 2n° 1/24/19 r 1/24/19 4th 1/28/19 BOTTOM TRIM HOUSE POINT B COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp Conditional Approval: Date ,,��G�F...QSI.I i W• Z-Atlie • •W /, teven ."llannorae. g.. CE 8149 . Appro Date -f(-17 i>i`,R? todA�r Inspection Report_1-1-12.doc • DESIGN PARAMETERS /I ` // ,` ' ,` !' ' `. �\ PRIMARY SEPTIC SYSTEM \ /I / / /' I I /' N 1 / NO. BEDROOM: 3 (450 gpd) / t I / /' ' TANK SIZE: 1000g I / I / / / / / / ii i ( \' ,.. ..,/ _/ PERC RATE: <1 MPI N / / / / / / / / / I SOIL RATING: 1.2 GPD/SF \ / // // // ///� ///// / ///' / SYS. TYPAREA DE: DEEP TRENCH 6'ED I /375 SF I / i/ / / // / '/� / / / // MIN LENGTH: 31.25 LF DECOMMISSIONED EXISTING TANK // ! ( _ .53 ..AND AND FIELD PER CODE. N41/4041, o •y USED: RE-ROUTE PLUMBING IN CRAWL-SPACE) - = y. 35LFx2.5'Wx6.0' E.D.. 10.0' TDTO THE WEST SIDE OF HOUSE. 'g W TOTAL AREA: 420 SF / ,/ / ,/ / / / / / // I \` _ N - I INSTALLED 1000g SEPTIC TANK / // I INSTALLED FOUNDATION CLEAN OUT/ // 1 AND DOUBLE CLEAN OUT / o - - / C71 CP U1 CP { (O / / I t o I o 1 0 / o l 0 � a i I l l I I I I • / r I I 3BR I � ` 1 I I I I I 1 , , / „ HOUSE I I I I I / I I l �F (E) i/ l II 11 y l / 1 30.7 I I I I I II II TH-11�. 1 ' ): I- - DRIVEWAY INSTALLED DRAIN FIELD ly Eg - - - 35LF x 2.5'W x 6.0'ED x 10.0'TD ., WITH MONITOR TUBE AND \ A B CLEAN OUT AT EACH END 1 24.1-- // FC 25.5 25.9 I ' ' I ` I I I I / ?S Ti 29.5 29.5 1 I / 1 1 / / I / T2 32.7 32.9 ! 1t / 1 1 I/ Il; II k\ LOT 232 DCO 35.8 30.0 1 1 I / II I / 1 ClI43.3 27.2 I 1 / /1 /'/// / �/- M1 45.5 25.1 I I I I I / / I / I C2 75.0 33.1 II y I I I I I 11 /1 - WELL(E) M2 73.1 31.2 / 1 it I , I /1 1 1 1 1 1 . 1 1 I I `,- ! I z <0 0 00 5 CO 2 4 < �'a ,T FILTER FABRIC .2 5 0-, w d jIJ p K K O 04 U U U p U DRAIN ROCK 6�ABOVE PIPE INV Z 78 -0100.0 - , § re O DRAIN PIPE m u - O.G.F•G. - - 97.5 _ TEST Ka[I ____...._ 1 . / I m ORGANICS 2 95.4/ 1000 g SEPTIC s51 / s TANK 5.0'OMAN ROCK gS.S PROFILE 6 POORLY`�°`° 9 S E AND SCALE:NTS 1I SOME SRTY SAVO 12DRY1310/29/18 14 • 15 16 DATE PERFORMED:10/19/18 NOTES: LLC 1�1��x\\, Dote RECORD DRAWING PANNONE ENG SVC, LLI. ...+SOF A( it 1/31/2019 P.O. BOX 100217 ANCHORAGE, AK 99510 r '%.••''' qS' �) - PHONE (907) 272-8218 FAX (907) 272-8211 /�g4.. `4� ..4-y+(1 Sco1e DRAWN BY: /-*. A• •, /\� . ./ 1"=50' ACP eial,�,, r P.I.D. NO T12N, R3W, Sec33, LOT 232 - �` :.� 018-322-12 LARRY SMITH & VIRGINIA WOLF � Steve R. onnoRe l PERMIT N0. ,?... CE 8149 ...p/ OSP181426 15302 OLD SEWARD HIGHWAY sr PLAN ANCHORAGE, AK 99516 ',i,-reo�ol ss�P�V. - Sheet 2 MUNICIPALITY OF ANCHORAGE Ori -Site Water & Wastewater Program PO Box 196650 4700 Elmore Road Anchorage, Alaska 99519-6650 Phone: (907) 343-7904 Fax: (907) 343-7997 http:/I,NvArv.muni.org/onsite Permit (Number: OSP181426 Work Type: Septic Upgrade Tax Code Number: 01832212000 Site Legal Address: T1 2N R3W SEC 33 LT 232 G:3134 Site Mailing Address: 15302 OLD SEWARD HWY, Anchorage Owner: WOLFE VIRGINIA W & Design Engineer: PANNONE ENGINEERING SERVICES This permit is for the construction of: Effective Date Expiration Date: Lot Size in Sq Ft: Total Bedrooms: 12/13/2018 12/13/2019 D Disposal Field 21 Septic Tank ❑ Holding Tank ❑ Privy ❑ Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (2417). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By:j%-i�r Issued By:�� t j Date: Date: 3""2C) �!/�C UHMPAUTY OF QMICHO AGE Community Development Department �' Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On -Site Water & Wastewater Program ON-SITE SEWER/WELL PERMIT APPLICATION Parcel I.D. 018-26f-12 Property owner(s) Virginia Wolfe & Larry Smith Day phone Mailing address 15302 Old Seward Highway, Anchorage, AK 99516 Site address 15302 Old Seward Highway Legal description (Sub'd., Block & Lot) Lot 232 Legal description (Township, Range & Section) T12N, R3W, Sec33 Lot Size 108,900 Sq. Ft. Number of Bedrooms 3 APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (® all that apply) Absorption Field ❑X Initial ❑ Single Family (SF) ❑X Septic Tank ❑X Upgrade ❑X (w/wo ADU) Holding Tank El Renewal❑ (D) E]Renewal Privy ❑ Multiple Dwellings ❑ (SF and/or D) Private Well ❑ Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Separation to steep slope Distance: 20' I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. (Signature of prope owner or authorized agent) Permit/Rush Fees: 60 Waiver Fees: Date of Payment: /. ! f aq. lq Date of Payment: Receipt Number: 0313 2rz-6 Receipt Number: Permit No. _ C��S �l �� �— Waiver No. Permit App__- : • :' ., c 0 0 & Municipality of Anchorage P.O. Box 196650 0 4700 Elmore Road Anchorage, Alaska 99519-6650 0 (907) 343-7904 a Fax (907) 343-7997 http://www.muni.or.q/Onsite 2Dgelvello@ment Services qgpgrtment On -Site Water and Wastewater Section Waiver#: OSV181099 COSA#: Permit#: OSP181426 PID#: 018-322-12 Legal Description: T12N R3W Section 33 Lot 232 Engineer: Pannone Engineering Services Applicant: Virginia Wolfe & Larry Smith NOW Your request for a waiver of the required 50 feet horizontal separation from the absorption field to the excessive slope has been approved. The approved separation distance is 20.0 feet. See engineer's waiver request and section drawing for justification. This waiver approval applies to the proposed absorption field only. Any future upgrade to the on-site wastewater disposal system will require all separation distances be met or another approval from this department. Z H Z 2 B U 2 a 0 2 M N 2 a a a a 2 a a a N a a M Z H H a K = 2 a U a M a Z H H ff Z Z 9 B a a R 9 a a 8 a 2 a a a a 8 a a a 8 a U a Z 0 a a 2 2 a a V a M as Waiver is Granted: X Waiver is not Granted: I Date: 12 6q 901 Approved by: lty_eee�, Name of Reviewer X a a N a 0 2 a a Z 2 U a a a a U a 0 2 Z a a a a 2 X 0 0 M I Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE CCMPu^mC �� �� �� , N-������������ ������i������ri���� ��erv8ceS LLC cmP/81*26,mL-bsxa{ano(l, 12�3* Steven R.Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com November 28, 2018 Septic System Install Permit Request Design Narrative This is a design narrative for a permit to install an upgrade septic system to be issued for this pnOperty. The proposed systems will serve an existing three bedroom (3) bedroom house. Currently the lot is developed, The existing drain field is in failure and will be abandoned per code. This lot and the surrounding lots are served by private wells. Required separation distances towells will be maintained. I. Soils. One test hole was performed on this lot by FES in October of 2018, and groundwater was monitored for at least seven days. Ground water was not observed to a depth of 16' below the surface inthe test hole monitor tube after the 7day monitoring period. Bedrock was not encountered in the test hole. Based on the results of the percolation tests and overall soils appearance; an application rate of1.2gaUons/clav/squarefeet was used fora conventional wastewater system in the area ofthe test hole. 2, Soil Absorption System Qesign, a. See Sheet I of the design package. 3. Surface Water: There isnosurface water within 1OOfeet ofthe proposed septic tank and drain field. The proposed drain field upgrade will maintain at least 100 feet from all surface water and drainage ditches. 4. Topography: The existing topography generally slopes from the east to the west in the area surrounding the septic system atapproximately Z% -]Y6. There i5aslope tothe west that exceeds 5O%. See waiver request. S. Drawing Markings: The Drawings are marked "For W1oAReview Qnly" When written notification that the review is complete and that there are no further comments is received from MoA On -Site Department, the note will beremoved and "Issued for [onstruction"drawings will beissued. The proposed installation will not affect the future development of this or the surrounding lots. Anchorage K8ai|iMg:P.[}.Box IOOZI7,A:Lhorage,AKS0S1-O-O2I7 Palmer Mailing: P,O, Box 1807, Pa|rn2r,AK99)G45 Municipality of Anchorage On-site Water and Wastewater REMEVVED FOR CODE COUPUANC Steven R.Pannone, Principal Registered Professional Engineer E-mail: steve@panengak.com November 28, 2018 Municipality ofAnchorage Development Services Department On -Site Water & Wastewater Program 47UOElmore Road P.O.Box 1966SO Anchorage, Alaska 99519 Subject: T12N, R3W, Sec 33, Lot 232 Septic System toSteep Slope Waiver Request Ladies and Gentlemen: I am writing to request a separation distance waiver between the proposed septic system and a slope of greater than 25% to twenty feet (20'). The soils in this area are typically Hydrologic Soils Group Avvhich contains organics underlain by poorly graded sand (SP),asshown onthe soils log. Due tothe nature ofand drainage capacity ofthe soils found inthe area (HSG A\the designed infiltration line of 45% for septic system installation on steep slopes should be used instead Of the assumed/worst case soil classification infiltration line ofZ5Y6. The slopes and soil types enable installation of any conventional system without the system effluent "daylighting" further down the slope ofthe hill provided bury depth requirements are met. Granting this waiver will not pose a threat to the safety of this lot or the surrounding lots. Anchorage Mailing: P.O. Box 10O2l7,AnchoraRe'AK9g5IO-02l7 Pa|merK8ai|in'a:P.O.Box 18O7,Pa(mer,Al<99645 Te(ephune:(307)7A5-8,Z0O FAX: (gO7)745-82O1 Page 2Of2 Please contact rneifyou have any comments orconcerns. Sincerely, Steven R. Pannone tj It Steven R. Pannone, P.E. Owner/Civil Engineer Attachments: -Site Plan &nchora�,e&;a]in-:P,O.Box1OOl17.Anch000e,AK9951O�)2l7 Pa|rxerk4ai|inno: P.O. Dox I807, Palmer, AK 99645 Teiephone:(9U7)745'X20] F(gO7 AX�)74�'�2O1 INSTALL 10OOg SEPTIC TANK (P) INSTALL FOUNDATION CLEAN OUT OUT AND DOUBLE CLEAN OUT 3 BRHOUSE (H - `~3^u /.3/ . 117 9^~ UPGRADE DRAIN FIELD / ^ � | -_DRIVEWAY � ' r--41. Y ! , J5LF x 2.5'W x 6.0'ED x 1O.0'TD a-~� W!TH MONITOR TUBE AND ~-c^-__-~/ � / \ CLEAN OUT ATEACH .END LOT ^�'�'7 \ '_`~ . ^_~._ � | Wcu(� N | /_IS H � �__~ ABBREVIATIONS TH TEST HOLE DESIGN �\ EA EACH |/ PRIMARY SEPTIC \ �` EACH ` ��� FCD FOUNDATION CLEAN OUT . NO. BEDROOM: 3 (450 gpg) / � � T# TANK CLEAN OUT NO. TANK SIZE: 10OOg C# CLEAN OUT NO. PERCRATE: <1 MPI W# MONITOR TUBE NO. SOIL RATING: 12GPD/SF R.I. RIGID INSULATION AREA ROD: 375 SF LEGEND� DCO DOUBLE CLEAN OUT SYS. TYPE: DEEP TRENCH O'ED ----vV------- WATER LINE/ Dv DNERTER VALVE 35LFx2.5'Wx5.0' E.D. '' USETOTAL AREA: 420 SF : ,a ruuVV 3ru/'cx (E) EXISTING SS NEW 10.0' TD ---- ---- (P) PROPOSED P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 z ik tjI,gST, Date S cole LARRY SMITH & VIRGINIA WOLF EIRE ;'Wl��"E' a lelE PERMIT NO. 15302 OLD SEWARD HIGHWAY CE -8149 OSP1 81426 PLAN ANCHORAGE, AK 99516 Sheet SPECIAL PROVISIONS TO SPECIFICATIONS 1. ALL CONSTRUCTION SHALL BE INSTALLED AS SPECIFIED IN THE MOST CURRENT EDITION OF THE MUNICIPALITY OF ANCHORAGE STANDARD SPECIFICATIONS (MASS) FOR COMPONENT PARTS AND MATERIALS USED IN CONSTRUCTION OF ON—SITE WASTEWATER DISPOSAL' SYSTEMS AND AND IN ACCORDANCE WITH AMC 15.65 AND 15.55. 2. SCOPE OF WORK: REMOVE AND REPLACE SOIL ABSORPTION SYSTEM AND SEPTIC TANK, 3. GROUNDWATER WAS NOT ENCOUNTERED TO A DEPTH OF 16 FEET BELOW EXISTING GRADE AS EVIDENCED BY THE SOIL TEST HOLE. IF AN APPARENT WATER TABLE IS OBSERVED IN ANY OF THE EXCAVATIONS LESS THAN 16 FEET BELOW EXISTING GRADE NOTIFY THE ENGINEER IMMEDIATELY. 4. THE CONTRACTOR (BOTH WELL AND SEPTIC SYSTEM CONTRACTORS) HAD THE WELL LOCATION AND SEPTIC LOCATION STAKED AND ANY LOT LINE AND WELL RADIUS SHOWN ON THE PLAN WITHIN 30 FEET OF THE PROPOSED SYSTEM STAKED BY A REGISTERED LAND SURVEYOR BEFORE STARTING THE WORK. 5. THE CONTRACTOR IS RESPONSIBLE FOR ALL R.O.W. AND OTHER REQUIRED PERMITS, OTHER THAN THE ATTACHED. 6. THE CONTRACTOR SHALL CALL FOR LOCATING OF ALL BURIED UTILITIES. 7. THE CONTRACTOR SHALL PROVIDE 24 HOUR NOTICE TO THE ENGINEER PRIOR TO START OF WORK. ALL SURVEYING AND LOCATES WERE IN PLACE PRIOR TO NOTIFYING THE ENGINEER. 8. THE CONTRACTOR SHALL NOTIFY THE ENGINEER OF ANY DISCREPANCY BETWEEN THE APPROVED DRAWINGS AND SITE CONDITIONS/LIMITATIONS POTENTIALLY CAUSING THE NEED TO MODIFY THE DESIGN. 9. AT THE COMPLETION OF THE WORK, THE CONTRACTOR SHALL SUBMIT RED—LINE AS—BUILT DRAWINGS TO THE ENGINEER. THE RED—LINES SHALL INCLUDE PIPE LENGTHS, ORIGINAL GROUND ELEVATIONS, PIPE ELEVATIONS, AND TANK ELEVATIONS. i 0. THE CONTRACTOR SHALL PROVIDE PHOTOGRAPHS OF THE SYSTEM INSTALLATION TO INCLUDE BOTTOM OF EXCAVATION, TOP OF PIPE WITH CLEAN—OUTS AND MONITOR TUBES INSTALLED, INSTALLED TANK AND FINAL GRADING. 11. THE CONTRACTOR SHALL PROVIDE DATA (UPON WHICH THE RECORD DRAWING WILL BE BASED) THAT REPRESENTS THE PROJECT AS CONSTRUCTED. THIS DATA IN CONJUNCTION WITH THE PERIODIC FIELD OBSERVATIONS BY THE ENGINEER (OR HIS DESIGNEE) AS REQUIRED BY AMC 15.65 DOES NOT GUARANTEE THAT THERE ARE NO HIDDEN DEFECTS BY THE CONTRACTOR. 12. THE CONTRACTOR SHALL SIGN THE FOLLOWING: 1 CERTIFY THAT ALL WORK WAS PERFORMED IN ACCORDANCE WITH THE APPEND PERMIT, AND ANY AND ALL CHANGE ORDERS, AND THAT THE AS—BUILT REDLINES ARE TRUE AND ACCURATE REPRESENTATION OF THE PROJECT AS CONSTRUCTED. CONTRACTOR: Mm DATE: TITLE: NOTES:P O C, L P.O. BOX 100217 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 �_1�ENOF ,rt4 lil+ = ��.. • �5�1, U ' 94, -4 4°th �� . ' .r � ',S� E �PANINONE It s''•. cE-$149 r`'fFo' w-'� ttt�ttitSSla``��~ Dote 12/5/2018 FOR CONSTRUCTION Scale NTS DRAWN BY: T12N, R3W, Sec33, LOT 232 LARRY SMITH & VIRGINIA WOLF 15302 OLD SEWARD HIGHWAY ANCHORAGE, AK 99516 DRM 018- ata -s222--12 PERMIT N0. OSP181426 DESIGN DETAILS Sheet 3 OF 4 1 2 3 4 5 6 7 10 ill 12 13 14 15 16 17 18 19 TEST HOLE 1 OR I ORGANICS POORLY SP/ GRADED SAND Sm ANDSOME � SILTY SAND S;011 S; I n(' . - PFR(ni ATInNI Tr: -,T SLOPE WAS GROUND WATER ENCOUNTERED? N IF YES, AT WHAT DEPTH? -DRY BOH DEPTH TO WATER AFTER MONITORING? -DRY DATE: 10/29/18 DATE PERFORMED: 10/19/18 Municipality of Anchorage On-site Water and Wastewater REVIEWED FOR CODE COWI JANCI n-sPiR149A P-pbe= CA '2/13/1 SITE PL 3 BR DATE CLOCK WATER NET TIME LEVEL NET DROP HOUSE TIME READING (E) 10/19/18 2 SOILS LOG DRIVEW 3 —m 4 0 < r . . .... ... CL LOT 232 SLOPE TH x READING DATE CLOCK WATER NET TIME LEVEL NET DROP FOR CONSTRUCTION TIME READING 1 10/19/18 2 SOILS LOG 3 WATER WAS ABSORBED TOO 4 FAST FOR ACCURATE MEASUREMENT 6 . . .... ... PEROLATION RATE _.<I (min/inch) PERC HOLE DIAMETER 6 inches TEST RUN BETWEEN 4 FT AND 5 FT COMMENTS: Test hole excavated by WILCO EXCAVATION. PERFORMED BY: Dan Moran. I CERTIFY THAT THIS TEST WAS PERFORMED IN ACCORDANCE WITH ALL STATE ANII-) N r- n.l -1 11 -n-r,- -1.. — ---- "111---1111 Date O 1, .....F ....A- 4'qs' it, 12/5/2018 Scole 49'th NTS P.I.D. NO . ............... 018-322-12 SIEVER 149 P"NONE.1: PERMIT NO. C-E-8 OSPI81426 Sheet 4 OF 4 NOTES: PNE ENG SVC, LLC P.O. BOX 102954 ANCHORAGE, AK 99510 PHONE (907) 272-8218 FAX (907) 272-8211 FOR CONSTRUCTION DRAWN BY: . :T12N, RX Sec33, LOT 232 LARRY SMITH & VIRGINIA WOLF 15302 OLD SEWARD HIGHWAY ANCHORAGE, AK 99516 DRM SOILS LOG "111---1111 Date O 1, .....F ....A- 4'qs' it, 12/5/2018 Scole 49'th NTS P.I.D. NO . ............... 018-322-12 SIEVER 149 P"NONE.1: PERMIT NO. C-E-8 OSPI81426 Sheet 4 OF 4 0410. 002 Client. Pannone Engineering Services Z.-" C, Pr6cct: 153,02 Old Se -ward I-Ii,,hwav J Date: November 11. 2018 1632 Bollevne C ircle 4 ncho Almko 99-5 15 Telephone 3§\3= 31981/E mail: cro i v1her MI Bratslaysky Subd. Lot 2 1574 Lot 1 N89°5851 "E 332.47(Plat No. 20'15-27) M EAST 330.00 (BLM) Chain link fe C Mj rW a 0 ! Story Frame 52.0 House -s.'.. 0.�- __ u Gravel driveway v 130A 10.3 a 28.0 f � t11 Q} O0) cy 6 _i E z° m o I` v 0 O WellO , C7 ° CO RS u> co v co � O C6 NQ � W J overed Storage O C Z CC WQ L LOT 232 o c3a� � O O a) � d Q CD T z U) m 0 O O C? t!J z (B fi} osition computed by distance -distance intersection N89050'17"W 330.00 (Computed) EAST 330.00 (BLM) Note: Lot 240 RECERTIFIED 11-13-18 -% There exists a 10' Access Easement for Lot 232 AS -BUILT NO CORNERS SET THIS DATE along the Westerly property line of Lot 1 A, i hereby certify that I have performed a Mortgagee's inspection Gold Pan Estates. of the following described property: LOT 232, SECTION 33, OF AC T12N, R3W S.M. AK Anchorage Recording Precinct. Alaska, and that the 49th `, improvements situated thereon are within the property lines and do not overlap or encroach on the property lying 00 i •" f ` ` adjacent thereto, that no improvements on the property lying Yr rf, f .:;�Fa fir_. adjacent thereto encroach on the premises in question and 0 Itlizabeth L. Wolatko : 4F oa that there are no roadways, transmission lines or other s. visible easements on said property except as indicated SCALE: 1 "= 50' -el 8036 - LS , 4�¢ �. hereon. tp p '°� Dated at Anchorage, Alaska EASEMENTS OF RECORD, OTHER THAN k�Fc'SSION�G•'�� this 12th day of February , 1970. THOSE SHOWN ON THE RECORDED tl � � FRED WALATKA & ASSOCIATES, L.L.C. PLAT ARE NOT SHOWN HEREON. FB 18-9 pg 28 (' ' G `> Engineers and Surveyors UNLESS OTHERWISE NOTED FB 70-2. pg 2 BE 907-248-1666 Alpine Drilling & Enterprises Well Log Permit Number: #SW 111287 Date of Issue: 10-11-11 Parcel Identification Number: 01832212000 Date Started: 10-17-11 Date Completed: 10-18-11 Is well located at approved permit location? x Yes ❑ No Legal Description: T 12N R3W Sec 33 Lot 232 Property Owner Name&Address: Wolfe Virginia W. 15302 Old Seward Highway Anchorage, Alaska 99516 Borehole Data: Depth (ft) Method of Drilling x air rotary ❑cable tool Soil Type,Thickness& Water Strata From To Casing type:steel Stick-up 0 2 Wall Thickness: .025 inches silt 2 5 Diameter: 6 inches Depth: 92 feet silty gravel 5 75 Liner Type: Diameter: inches Depth: feet gravelly silt 75 90 Casing stickup above ground:2 feet silty water sand&gravel 90 96 Static water level(from ground level): 70 feet silt 96 97 Pumping Ievel: 95 feet after 2 hours pumping 10 gpm Recovery Rate: 10 gpm Method of Testing: air l f Well Intake Opening Type: ❑Open End ❑ Open Hole x Screened Start 91 feet Stopped 97 feet ❑ Perforations Start feet Stopped feet Grout Type: Bentonite Volume: 1 bg Depth: Start 0 feet Stopped ? feet Pump: Intake Depth feet Pump size hp Brand Name Well Disinfected Upon Completion? x Yes ❑No Method of Disinfection: chlorine tablets Comments: The existing well located on the above property was decommissioned per AEDC and MOA requirements. Well Driller: Alpine Drilling&Enterprises PO Box 110496 Anchorage AK 99511 Development Services Department Building Safety Division Vt 8L • ; On-Site Water & Wastewater Program Dom* l 1 4700 Elmore Road P.O. Box 196650 1.11 I i L Mark Begich Anchorage, AK 99507 s A E T Y Mayor www.muni.org/onsite (907)343-7904 Pump Installation Log Well Drilling Permit Number: sw///,)'7 Date of Issue: /9/r7/� Parcel Identification Number:2i 2Q 2IZ Legal Description Property Owner Name&Address: "-(7e- 2.51 (53G& ie' .Sec--E-). /%ti 7, cL, /JCC ?(2.5-/6 Pump Installation Date: I'uuih Intake Depth Below Top of Well Casing: 555j feet I'u n Manufacturer's Name: h /�_5 Pump Model: 75,5 61.5 Ct /2 C. L Pump Size L'2 hp Pitless Adapter Burial Depth: 1( feet Pitless Adapter Manufacturer's Name: 04&-.,e3c✓ Pitless Adapter Installer: c.-4 Well Disinfected Upon Completion?El Yes ❑No Method of Disinfection: 1/4---4, ,,- �`i, e.,- Comments: Pump Installer Name:j7 xi -' ///147A-71-%e_.• 'f14c / e,.. v�- Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. On-Site Water System Permit • [ �Vitae MUNICIPALITY OF ANCHORAGE ,. Development Services Department On-Site Water& Wastewater Program irrtild 4700 Elmore Road, PO Box 196650 1� ' „ I,,,, ,'t Anchorage, AK 99519-6650 Telephone: (907) 343-7904 Permit Number: OSP111287 Tax Code Number: 01832212000 Work Type: Well Upgrade Permit Effective Dates: October 11, 2011 to October 10, 2012 Design Engineer: Subdivision: T12N R3W SEC 33 Site Legal Address: T12N R3W SEC 33 LT 232 G.3134 Owner/Address: WOLFE VIRGINIA W 15302 OLD SEWARD HIGHWAY ANCHORAGE AK 995163954 Site Mailing Address: 15302 OLD SEWARD HWY, Anchorage Lot Size in Sq Ft: 108900 Total Bedrooms: 3 This permit is for the construction of: N Disposal Field N Septic Tank N Holding Tank N Privy Y Private Well N Water Storage All construction must be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80). 3. The wastewater code requires inspections during the installation. The engineer must notify the Development Services Department at least 2 hours prior to each inspection. Provide notification by calling (907) 343-7904 (24 hours). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather must either A. Open and Close on the same day. B. Covered, sealed, and heated to prevent freezing Received By: Date: /47/i7/.// Issued By: A.,ze./--- 141,or , Date: /VS/ MUNICIPALITY OF ANCHORAGE fr:)11 Community Development Department l/ Phone: 907-343-7904 Development Services Division Fax: 907-343-7997 On-Site Water & Wastewater Program Mayor Dan Sullivan / ON-SITE SEWER/WELL PERMIT APPLICATION SUSI FOR A SINGLE FAMILY DWELLING �y/ Parcel 1.D. ofd 312_ 12_ o crd • Property owner(s) t/ (ROMA W p C E. Day phone .3(15- 87P9 Mailing address 15-3Q2 OLO S>°WA al) 14 1 +KW t y 4N QQS%G Site address Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) `r' f - K 7 . 3 U Ste- 3 3 L.- 2. 32. Lot Size /0 $ � 7 ooSq. Ft. Number of Bedrooms THIS APPLICATION IS FOR: THIS APPLICATION IS AN: (®all that apply) Absorption Field ❑ Initial ❑ Septic Tank ❑ Upgrade El Holding Tank ❑ Renewal ❑ Privy ❑ Private Well aci Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE/WAIVER REQUEST FOR: I certify that the above information is correct. I further certify that this application is being made for a Single Family Dwelling and is in accordance with applicable Municipal Codes. (Signature of property owner or authorized agent) Permit/Rush Fees: dtjp ��j- f` y1 Waiver Fees: Date of Payment: tO--14 -\1 Date of Payment: Receipt Number: Mco(o$( Receipt Number: Permit No. O P \\\a l Waiver No. G:\Building\On Site\Forms\Client FormslPermit App_010411.doc (Rev_ 1/11) OnSite Mon Oct 10.09:28:35.2011 Map: OnSite litill • . N E �--\ $ z'1C'— T�1�iCon11 J i 16 01 0 4 LD`-'7,1- ' C rtc)cc�1 wE Lbw s��c--� '.�.�.� �t��A4 _ •7 FT- 2-3 2-32- _ 5071 Scale 1:1200 • ` :. rr'X?t i / 7i7i� C Legend: l'0 . - PRD (X1 tli, r rr-f., SEWER_MANN 8 3 .,'- a / rxt STREET NAME, \ / / iY ii ]i PARCELS VVV 2.)C S 1--T Lk, 6 t.,u c L.L. WILL /J C bi c l rrl m,S s, 6 Al4'f2 POA- C-e I)( 2 1 • CiWViewn" Municipal Software Corporation ' i J FHA Form 7573 Form A • L...S.OL PAN tµCNi 01 nJ,., IW.AND URBAN DEVt1i,'MEN' ppor.d hr.July WOWdp.,forego Ho. 63-R2116.ftDt-VAI. HCA I',IN;:.;IMIN15IRA T:fN i` HEALTH AUTHORITY APPROVAL INDIVIDUAL WATER SUPPLY AND SEWAGE DISPOSAL SYSTEM PART 1.—TO BE COMPLETED BY FHA INSURING OFFICE •MORTGAGEE SERIAL NO. Anchorage, Alaska � First National Bank of Anchorage 10135 MORTGAGOR OR SPONSOR 1PROPERTY ADDRESS • Wayne A. Mahurin Seward Highway & Rabbit Creek Road, ----- .. -- , ..-. _.Anchorage,Alaska - SUEDIVISION NAME, 1—/LOC-- K NO. LOT NO. Sdc. 33; T12N, Rik, S.M. 1 232 T TOTAL NLIMEER: j EASEMENT ® Con attic w other area be made Into LIVING u.,„ up.... I New installation I additional bedrooms? (If Yes, how monyi) L1 I 3 I 2 —� 0 Yes ® No ElYes1;2No I WATER SUPPLY IT SYSTEM DESIGNED FOR Public system ri Community system D Individual F NO. of Sisuas.T— GAF►.at DISPOSAL SEWAGE DISPOSAL{Ya ! t ElPublic system 1 ' Community system ❑ Individual 1 n Yes ❑ No i . PART 11.—TO BE COMPLETED BY HEALTH DEPARTMENT i HEALTH DEPARTMENT .NSPECTOR'S SKETCH II - —-�.--- _- i_���, _ttt: -i _ _ II . ' . L .___,' _ „a_ i t t 4. , 4._ vr , I , -0--.--..--.- t--I•t -I--•-•1,-- • inisiM ....—_,--.4 —__...._ r +- j-, _,, ,______ , r r, , br- sii _____ _.............1 t ....._._,__._ I. ----4--- -1,..._ 4._:if_ . _-__t__":„..._4-,-,, __-- -• , ' —1III ----1- - 4- T--""""---""---"------".- . 4.- 1 1 4 Pill it • _ i _ I • _ -14 �— . , w _Tr A. It is the opinion of the ❑ State EllCounty ❑ Local Department of Health that this individual water-supply system Elis n is not satisfactory as a domestic water supply for the subject property. It is the opinion of the ❑ State n County J Local Departm"•nt of Health that this individual sewage-disposal sys- tem with proper maintenance: DCan be expected to function satisfactorily, and ❑ Cannot be expected to function satisfactorily is not likely to create an insanitary condition - DATE SIGNATURE 1 TITLE July :23 1970 j - ._ ---,------ - ! Environmental Health Supervisor NOTE: The health authority should complete the appropriate opinion statement above and oflie date, signature and titie in the spaces provided. u.. ..4 •I.. wk.... ,...iw ►... u�..,.h. a.............. 1............,. .L ...s. ... ._.Il ,._ ..-- -s.1.- L__s. -. .kJ_ ...-- :_ -. .k.- --•'-- -A...- q,-! 7t ( il- ill • l/ - //,`3 a 072_9 2 0 L11 ` 1✓ ` ,) REQUEST FOR , ' I 4t,' ' it //AAPP/PROVAL OF 7A. INDIVIDUAL SEWAGE AND WATER FACILITIES (Fill out in Triplicate) —— . Name of person requesting approval ,/ 2. Name of property ,[,G owner a ;)/476Z.141,6/<„), .3/ __X 3. Legal descriptio . 3 ' ,, C. . 666e-i__4. Number,of bedrooms in house --3 , ' 2�-�'/�� 5. WaterAn.alysis: ��/ //! a. Bacterial 1 )( bL Zi ' b. Detergent &(/?t/6° '�j5 6., Well data: Ltri-"aj:ivot, W . a. Typ e le ut--cd-..-, . ‘9) 4" / ili b. Depth /, iftttill c. Casing Size . elf . - I d. Distance from well to closest existing or proposed: 1. Sewer line . 2. Septic tank ` ! . 3. Seepage Area / i /. 4. Cesspool' . l ', 5. Property Line -1- . 6. Other sources of possible contamination, i.e. , creeks, lakes, houses, barn, drainage ditch, etc. 7. Sewage disposal system. a. Age of system l / CL2' . - b. Septic tank capacity in gallons Sq c. Name of septic tank manufacturer . Q -- 4-0_, 14t 100 1. If "home made" show diagram on reverse side of this f gpit size and YP P ' ' k/t/) 14* rm d. Disposal fie or seepage et e 1'__ �- l - i - 1. Distance to pr..erty line le' s to house foundation `,d d-- . 0 II .1 111 e, PercczJatiou Test results f. Percolation Test performed by Use the reverse .side of this form to show diagram. Diagram should include —. he following information : property lines; •well location, house location, septic tank location , disposal area location, location of percolation test , ani. direction of Around slope. 9. The information on this form is true and correct to the best of my knowledge. Signature of Applicant Date Sinned '10 BE FILLED OUT BY HEALTH DEPAFTENT PERSONNEL he above described sanitary facilities are hereby approved, subject to the following conditions: Conditions: ,.,YJ.e-7'r C r n The above described sanitary facilities are disapproved for the following reasons: �� � 2cc �l'"� I il ^ 7 /ice Si;7' r�of tlt ick 2,: - Date f. L i, t•� ... Approval is valid for one year following the date of approval. CPJ :cw ' EPLI#*1-191413 ' r Municipality of Anchorage On-Site Water and Wastewater Program (907) 343-7904 5 t Certificate of On-Site Systems Approval Parcel I.D. 018-322-12 Expiration Date: ST— ( 1 1 q 1. GENERAL INFORMATION Complete legal description T12N R3W SEC33 LOT 232 Location (site address) 15302 OLD SEWARD HIGHWAY Current Property owner(s) LARRY SMITH & VIRGINIA WOLF Day phone Mailing address SAME Real Estate Agent Day phone 2. TYPE OF DWELLING: El Single Family(w/wo ADU) ❑ Duplex ❑ Multiple Dwellings (Single Family and/or Duplex) 3. NUMBER OF BEDROOMS: 3 4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL: Individual Well 0 Individual El Individual Water Storage ❑ Holding Tank ❑ Community Class Well ❑ Community ❑ Public Water System ❑ Public Sewer ❑ Waiver/Variance request for: Distance: Received by: Date: COSA to be released to the engineer,unless otherwise requested by the engineer. COSA Fee $ atilQ Waiver Fee $ Date of Payment A`74161 Date of Payment Receipt Number OQp.5-7 Receipt Number COSA# O5 / 9/O35 Waiver# • 5. STATEMENT OF INSPECTION BY ENGINEER As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation, based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application, shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate for the number of bedrooms and type of structure indicated herein. I further verify that based on the information obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water supply and/or wastewater disposal system is(are)in compliance with all applicable Municipal and State codes,ordinances,and regulations in effect at the time of installation. In conducting an adequacy test,I attempt to provide a thorough,conscientious engineering analysis of the system in accordance with MoA COSA guidelines and regulations.The reported results describe the performance of the system under the conditions encountered at the time of the test, and separation distances measured to readily identifiable features. The operational life of all wells and septic systems depend on the local soil condition,ground water levels that may fluctuate during the year,and the water usage of the family being served by the system.These conditions are outside the control of the evaluator of this system. All systems eventually fail and satisfactory test results do not guarantee future performance of the system,nor do they guarantee that there are no hidden defects or encroachments.Therefore we cannot provide any warranty for future performance, nor can we estimate remaining life of the system.The content of this report is for the sole benefit of the owner listed above. Name of Firm Pannone Engineering Services LLC Phone (907) 745-8200 Address P.O. Box 1807 Palmer, AK 99645 Engineer's Printed Name Steven R Pannone, P.E. Date /'?'c'63 of At.44 ti 6. DSD SIGNATURE '•• 04�SP •••�i System #1 Approved for bedrooms �� tleven k. •-annone ••'•'r System #2 Approved for bedrooms '•, CE-8149• Disapproved 'k • S90 Conditional approval for bedrooms, with the following stipulations: uN-SIT wq ATER AA/0m rPcINpR�� wATER Rgtijo SRvic* By: Original Certificate Date: 2--1I I �/ The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality of Anchorage is not responsible for errors or omissions in the professional engineer's work. 7. ATTACHMENTS: COSA Checklist X Nitrate Advisory Septic System Advisory Arsenic Advisory Well Flow Advisory Other COSA b'ue sheet_f - • If more than 1 septic system is on the lot: COSA Checklist# 1 of 1 Structure served by this system 1 Certificate of On-Site Systems Approval Checklist Legal Description: T12N R3W SEC33 LOT 232 Parcel ID:018-322-12 A. WELL DATA Well type Private If A, B, or C provide PWSID# Well Log(Y/N) Y Date completed 10/18/11 Sanitary seal (Y/N) Y Wires properly protected (Y/N) Y Total depth 97 ft. Cased to 92 ft. Casing height (above ground) 24 in. FROM WELL LOG AT INSPECTION Date of test 10/18/11 1/28/19 Static water level 70 ft. 69.0 ft. Well production 10.0 gpm 4.4 g p m WATER SAMPLE RESULTS: Coliform 00\ colonies/100 mL Nitrate '�/3 mg/L Arsenic t.,\'_. ug/L Date of sample: t(a3 l ft Collected by: !._ T E S B. SEPTIC/HOLDING TANK DATA Tank Type/Material Septic/ Plastic Date installed 1/23/19 Tank size 1000 gal. Number of Compartments 2 Cleanouts(Y/N) Y Foundation cleanout(Y/N) Y Depression over tank(Y/N) N High water alarm(Y/N) N/A Date of pumping NEW Pumper C. ABSORPTION FIELD DATA Date installed 1/24/19 Soil rating (g.p.d./ft2 or ft2/bdrm) 1 .2 System type Deep Trench Length 35 ft. Width 2.5 ft. Gravel below pipe 6.0 ft. Total depth 10.0 ft. Eff. absorption area 420 ft2 Monitoring tube Y Depression over field N Date of adequacy test New Results (Pass/Fail) For 3 bedrooms Fluid depth in absorption field before test in. Water added gal. New depth in. Elapsed Time: min. Final fluid depth in. Absorption rate >= g.p.d. None KnownAny rejuvenation treatment(past 12 mo.) (Y/N &type) If yes, give date D. LIFT STATION Date installed Size in gallons Manhole/Access (Y/N) "Pump on" level at in. "Pump off'level at in. High water alarm level at in. Datum Cycles tested Meets alarm&circuit requirements? E. SEPARATION DISTANCES WELL ON LOT TO: Septic tank/lift station on lot 1001+ On adjacent lots 1001+ Absorption field on lot 100 + On adjacent lots 100'+ Public sewer main 75'+ Public sewer manhole/cleanout 100 + Sewer/septic service line 25'+ Holding tank 100 + Animal containment areas 501+ Manure/animal excrete storage areas 100 + SEPTIC/HOLDING TANK ON LOT TO: 11 Building foundation 10 + Property line 10 + Absorption field 10'+ Water main 25 + Water service line 25 + Surface water + Wells on adjacent lots 100 + ABSORPTION FIELD ON LOT TO: 101 Property line 10 + Building foundation 10 + Water main + Water Service line 25 + 1Surface water 00 + Driveway, parking/vehicle storage 101+ Curtain drain 50'+ Wells on adjacent lots 100 + F. COMMENTS G. ENGINEER'S CERTIFICATION ,r+' AN Ikvt I certify that I have determined through field inspections and '�pjA�P'• j4... 9{I review of Municipal records that the above systems are in Al,*; , • .j ••*vf conformance with MOA COSA guidelines in effect on this date. ,•�414'��� • Engineer's Printed Name Steven R Pannone, P.E. " •':Steven -.•ISon orie:••/ Date /CM Gi 61:. CE-8149 � r liU . .�Y thES900.-4S.\�-%1� COSA canary sheet_2-6-15.doc I Bratslaysky I Subd. Lot 2 1574 Lot 1 N89°58'51"E 332.47 (Plat No. 2015-27) M EAST 330.00 (BLM) Chain link fen.. C M W-.:1721049 — !:� ~20. 32.0 0 .- 38.3 ni .'�.•Ch. 1 Story Frame 52.0 ., .. l y - y-- ....t --60.� w House C • Septic Vents(typ)--__•• Gravel driveway • 10.3 c 28.0 180.1 Van . -J CO 0) O '� a O N a) r O O �. __JE Z EP O M 00 Z u) OCO • O Well0 O •CO O N CO CO O 9 O M W J overed Storage Z O W M `6 Cr) a o � Pr- LOT 232 cn? o O M O N E0 Q Co 0 Z i CO o OO J cnZ N CU CO ,Position computed by distance-distance Intersection / N89°50'17"W 330.00 (Computed) • EAST 330.00 (BLM) ) RECERTIFIED 01-28-11'2:( I Note: Lot 240 RECERTIFIED 11-13-18 There exists a 10'Access Easement for Lot 232 AS-BUILT NO CORNERS SET THIS DATE along the Westerly property line of Lot 1A, I hereby certify that I have performed a Mortgagee's inspection Gold Pan Estates. _ .\ \\ \ ‘% of the following described property:LOT 232. SECTION 33, ` PSE OF .AL,' T12N, R3W, S.M. , AK • 49th `4� •�•9 /` Anchorage Recording Precinct,Alaska,and that the �� improvements situated thereon are within the property lines . '. •• •* r and do not overlap or encroach on the property lying e , • ••j� • adjacent thereto,that no improvements on the property lying .. . �. —adjacent thereto encroach on the premises in question and f 1+ •. lizobeth L. Walatka:I / that there are no roadways,transmission lines or other �„ visible easements on said property except as indicated SCALE: 1 50' �`�'F1'e,•••�36 - LS ,•'y���'� hereon. o • • • . • o Dated at Anchorage.Alaska EASEMENTS OF RECORD, OTHER THAN PRC ssioNA� tea, this 12th day of February ,1970. THOSE SHOWN ON THE RECORDED ' k k\\\•�` FRED WALATKA&ASSOCIATES,L.L.C. PLAT ARE NOT SHOWN HEREON. FB 18-9, pg 28 ' 17-41- t 1Engineers and Surveyors UNLESS OTHERWISE NOTED FB 70-2, pg 2 FB 19-1 pg 15 BE 907-248-1666