Loading...
HomeMy WebLinkAboutT15N R1W SEC 8 LT 113Onsite File -0,q ............ Municipality of Anchorage On -Site Water and Wastewater Program - (907) 343-7904 Page 1 of 3 ON-SITE WASTEWATER INSPECTION REPORT Permit Number: OSP171220 PID Number. 051-151-19 ing: FIC Single Family (SF) ❑ Duplex (D) El Multiple (SF and/or D) Project: [E New ❑ Upgrade Name: Brian & Amanda Cook ABSORPTION FIELD 0 Deep Trench 9 Shallow Trench El Bed ❑ Mound Address 21464 Sunflower Lp, Chugiak, AK 99567 E] Other Phone Number of Bedrooms Soil Rating depth from original grade 351-4440 4 JTotal 0.6 GPD/SF 9.1 / 9.4 Ft. LEGAL DESCRIPTION Depth to pipe invert from original grade 5.1 /5.2 Ft. Gravel depth beneath pipe 4.0 / 4.2 Ft. Subdivision Block Lot 113 Fill added above original grade 1.0/1.0 Ft. Gravel length 50 / 50 Ft. Township Range Section 15N 1W 8 Gravel width 5.0 Ft. Beds: Number of Lines Distance between lines Ft. SEPARATION DISTANCES Toj Septic i Absorption 1 Holding Sewer 'o' Total absorption area Number of trenches Dist. between trenches Lift Station From I Tank Field Tank Line 2 1000 Ft 2 >10 Ft. Well / >1 oul! >10u, N/A NA >25' TANK ®Septic F-1 S.T.E.P. 1771 Holding r_1 Other Manufacturer Anchorage Tank Capacity I 1250 Gal. Surface Water >100' := >100' N/A N/A Material Number of compartments Steel 2 Lot Line >10' >10' N/A N/A NA F Foundation > o 10, >10, N/A N/A LIFT STATION Manufacturer Capacity Curtain Drain i None Noted Gal. Remarks Pump on level at in. Pump off level at in, High water alarm at in. Pump make and model Electrical Inspections performed by to PIPE MATERIAL House to tank D3034 Tankdrainfield D3034 Installer Owner Install Drainfield D3034 CO/MT D3034 Inspector J.Millette, B. Schiller BENCH MARK (Assumed elevation) 100 ft Inspdates:ection 1,,10/3/17 12/23/17 Location and description 2nd 3d 4th Garage Slab COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL Engineer's Stamp 0 F Conditional Approval: Date 19, *T h nenian �S&Jller 101 Approved fl /01/19 19592 11/7/18 . ellI .. - - .... t4; Date I Inspection Report_9-1-12.doc Tl 5N R1W SEC 8 LT113 PERMIT # OSP171220 PID # 051-151-19 x � 50' R.O.W!, RESERVE O / / r Lot 96 If t=Iv ALTERNATE SIT �fio. �:.: ` . 2S. �s, SO d I `sti , p •O c� g I� WELL E Lot 112 I" .. .. ... ../........ . • Benjami chiller �Fc •. CE 1 92 .••��i Aor09.2018 .'_X\ A B C FCO 17.1 6.0 SV1 51.9 41.3 SV2 61.5 48.0 2CO 65.5 50.4 C01 82.1 48.5 MT1 81.6 47.3 CO2 73.8 74.7 CO3 98.0 65.2 MT2 92.0 85.7 C04 90.1 85.4 JA 0 50 100 FEET 1 "=50' 1250 -'GAL -SEPTIC TANK / 2x 50' LONG xi5' WID , 4' EFFECTIVE,DEPTH ABSORPT16N TRENCHE t l t I 1 i � t T15N R1W SECS LOT 113 50' R.O.W. RESERVE LEGEND CO - CLEANOUT 2CO - DOUBLE CLEANOUT FCO - FOUNDATION CLEANOUT FS - FLOW SPLITTER VALVE MH - MANHOLE MT - MONITORING TUBE SV - SEPTIC VENT TH - TEST HOLE r I— 0 m N fx W z z MUNICIPALITY OF ANCHORAGE DEVELOPMENT SERVICES DEPARTMENT 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 SOILS LOG AND PERCOLATION TEST LEGAL DESCRIPTION: T 15N R I W SEC8 LOT 113 PERFORMED FOR: BRIAN COOK DATE: 9-26-2017 PROJECT No.: PARCEL ID#: 051-151-19 TECHNICIAN DEPTH TEST HOLE 1 REV (feet) 1 .,.. 2 3 4 5 SILTY SAND 6 7 8 9 10 11 �•�" 12 14- 16- 17- 18- 19- 20 41617181920 COMMENTS J. MILLETTE SLOPE WAS GROUND WATER ENCOUNTERED? NO IF YES @ WHAT DEPTHI S DEPTH OF WATER AFTER MONITORING: NONE L DATE OF MONITORING: 10-3-17 liJ E SITE PLAN SEE SITE PLAN DATE READING GROSS TIME (MINUTES) NET TIME (MINUTES) DEPTH TO WATER (INCHES) NET DROP (INCHES) TEST HOLE PRESOAKED PRIOR TO TESTING: 7-27 1 7:20 0" 2 7:50 30 3.75" 3.75" 3 7:51 0" 4 8:21 30 1 3.50" 3.50" 5 8:22 0" 6 8:52 30 3.50" 3.50" PERCOLATION RATE: 8.5 (MIN/INCH) PERC. HOLE DIA. 6 —jINCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. TEST HOLE DEEPEND TO 16' AND MONITORED FOR GROUND WATER DUE TO CHANGED ELEVATIONS ON SEPTIC TANK AND TRENCH OWNER OFLAND: Brian Cook ADDRESS: Bore Hole Data Depth From To LEGAL DESCRIPTION T15NR1\NSEC OLOT II3 DATE: 9-28-17 PERMIT NUMBER: ospzrzzZO DATE OpISSUE: 8-15-17 TAX IDENTIFICATION NUMBER 05115119000 F7 |swell located atapproved permit location: i>(Yes| |No �� Method of Drilling: �� ��airrotary L_|cab|etoo| Depth of Well: 245' [asingType: Steel Wall thickness .250 inches Diameter: 6 inches, depth 245 feet Liner type Static Water Level: 79 feet Recovery Rate 15 M Qpnn F] Qph Method of Testing Air F7 Well Intake Opening Type: LXJopen end | |openho|e F—) Screened Start feet Stopped 1-1 �Pe�orabons �1a� feet Stopped Grout Type: Bentonite Volume: 50 lbs Depth: from Z feet, to 42 feet Well Disinfected Upon Completion: iXJyes Eno Method of Disinfection: Chlorine 50 PPM Comments: 4 51 51 90 90 155 155 160 160 179 179 185 185 221 221 239 239 245 Casing Stickup Overburden Silty Sand &Gravel Tight Silty Sand &Gravel Silt Gravel &[|ay Silt & Sand Water Clay &Gravel Clay & Gravel Water Clay Clay 8'Gravel Silty Sand &'Gravel Clean Water Drillers Name: Cole Sullivan ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority. W1unidpe|hY of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation. KAat3uBorough: Department ofEnvironmental Conservation. Pump Installation Log Well Drilling Permit Number: SW OSP171220 Date of Issue 8-15-17 Parcel Identification Number: 05115119000 Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation. �`"°""'� MUNICIPALITY HORA 4, ... oR 1.J On-Site Water & WastewaterOFANCProgram X11, 5 PO Box 196650 4700 Elmore Road f Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997 httpalwww.muni.orglonsite i t. I),•l,ai Inik•ni ,SCM ON''t On-Site Water & Wastewater System Permit Permit Number: OSP171220 Effective Date: 8/15/2017 Work Type: WellSeptic Initial Expiration Date: 8/15/2018 Tax Code Number: 05115119000 Site Legal Address: T15N R1W SEC 8 LT 113 G:1257 Site Mailing Address: Owner: KROENER HILDA E Lot Size in Sq Ft: 108900 Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 4 This permit is for the construction of: 0 Disposal Field Q Septic Tank El Holding Tank ❑ Privy Q Private Well ❑ Water Storage All construction shall be in accordance with: 1. The attached approved design. 2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80) 3. The wastewater code requires inspections during the installation. The engineer shall notify the Development Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7). 4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather shall be either: a. Opened and Closed on the same day, or b. Covered, sealed, and heated to prevent freezing Received By: triaek Date: 5 Issued By: ;`ie('A Date: g1/71°r 7 MUNICIPALITY OF ANCHORAGE Community Development DepartmentPhone: 907-343-7904 Development Services Division Fax: -1343-799Z On-Site Water & Wastewater Program X45 \\ ti ON-SITE SEWER/WELL PERMIT APPLICATION AUG 0 Parcel I.D. 051-151-19 �6 Brian Cook 3514440 ," Property owner(s) Day phone y Mailing address 16620 Brooks Lp, Eagle River, AK 99577 Site address NHN Old Cranberry Rd Legal description (Sub'd., Block & Lot) Legal description (Township, Range & Section) T15N R1 W SEC8 Lot 113 Lot Size 108,900 Sq. Ft. Number of Bedrooms Four APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING: (®all that apply) Absorption Field El Initial 0 Single Family (SF) 0 (w/wo ADU) Septic Tank 0 Upgrade ❑ Duplex (D) ❑ Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑ Privy ❑ (SF and/or D) Private Well 0 Water Storage ❑ THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR: Distance: I certify that the above information is correct. I further certify that this is in accordance with applicable Municipal Codes. / z (Si a ure of p operty owner or authorized agent) Permit/Rush Fees: 60 t P1673 -leg Waiver Fees: Date of Payment: gilt) L,(1 Date of Payment: Receipt Number: QR I 1 t C Receipt Number: Permit No. 05911 12-2-o Waiver No. Permit App_9-1-12.doc ANDERSON ENGINEERING P.O. BOX 240773 ANCHORAGE, AK 99524 522-7773 677-7766 (FAX) August 9, 2017 Municipality of Anchorage Development Services Department On-Site Water and Wastewater Program 4700 Elmore Rd Anchorage, AK 99519-6650 Subject: T15N R1 W SEC8 Lot 113 Septic System Design and Permit Application Impacts to Adjacent Properties Dear Onsite Services Engineer: The owner of the Lot 113, at T15N R1W SEC8 intends to construct a new four- bedroom home on the lot. We are therefore requesting a permit be issued for the construction of a new well and septic system to accommodate the home. The attached Site Plan and backup documentation identify the location and configuration of the proposed well and septic system along with the alternate site. Also identified on the plans are the existing wells in the area and septic systems on surrounding lots. No conflicts exist between the proposed septic system and the existing septic systems and wells on this and adjacent lots. Drainage arrows and ground surface contours are shown on the site plan showing the grade and direction of flow on the lot. The drainage pattern will not be changed as a result of this project. The test hole placed on the lot in the area of the absorption trenches and alternate site indicates silty sand. This test hole was perked, and a second perk test was performed about 60' away. The soils were very hard, although the percolation rate was tested at under 10 minutes per inch. No groundwater was found during the placement of the test hole and none was found during the monitoring period. A conservative application rate of 0.6 gallons per day per square foot was used in the design of the absorption system. We are proposing to place a new 1 ,250-gallon septic tank and two 50' long by 5' wide by 4' effective depth absorption trenches to treat and dispose of the effluent generated in the house. The elevation of the distribution line in the absorption trench will be 2.0' below the surface and the total depth will be 6.0'. A minimum of 2" of insulation and 2' of fill will be placed over the absorption trench and septic tank. The ground surface on the lot in the area of the septic system slopes to the northeast at a shallow grade. The new trench will be constructed parallel to the ground contours in conformance with Municipal requirements. The new septic system will be constructed a minimum of 100' from all wells and any surface water and 10' the proposed and existing water services in the area. If the system is constructed in accordance with our design the following statements apply: 1. The system, if constructed as designed, will have no adverse impact on the wells in the area or those to be constructed in the future. 2. The system, if constructed as designed, will have no adverse impact on existing septic systems in the area or those to be constructed in the future. 3. The system, if constructed as designed, will have no adverse impact on reserve space, either surface or subsurface, on any lots located in the area. 4. The system, if constructed as designed, will have no adverse impact on drainage patterns in the area. The current drainage pattern will be maintained. ���'samn Sincerely, N, 0 A ,�leih sse PI :*. 49TN to Benjamin Schiller, P.E. ••• '4 """" Attachments 'Baja f I '/ � "� 2 .* _-- , I ; . g/---- , . I , _ . I a t•I \ \ i 0 PROPOSED WELL \ 'N. 2x 59 1_F SEPTIC TRE CH 6 ;IN \ 5' WIDE, 4' EFFECTIVE DEPTH ZcIt- -,. -- -- I R • . . ;?...: •.• .. - -77 -+ - - - • -,),5-.., -0 erk Test 2 cc$ / C • CO 0 r‘ 1 ALTERNATE .-- ---- ' 1 •. 2 % 1, SITE .'N:. ' :-., 10 0 MT II \ / • t ‘ 1 k / 7)1\° \ / SV 1 1 i k i \ / SVIO, 1 t 1 ; t t 1 ; t / /\• / . t \fl ; t N . / 2C0 riA-OL.3 LI / , Lot 1 1 2 4-13DRM H9ME FC00 --.. -- 10.0 CA .:1..!INNTH#( _1 -_. _, _-- LA ..._ co v) dx 100WELL RADIUS ILL.1 z I-- z M \ 1 T15N R1W SEC8 \ ) LOT t13 [ 100' WELL RADIUS \ N --.. —,— i .' ---' ,/ —50' R.O.W. RESERVE ./ JAYHA1NK DRIVE •Arkt• *.i'ii 0*:49111 .* 0; .... . ......„:.... . OA. , ra . Ben in Schiller : lifo.... AEL 12592 .• `4Al' 0 50 100 TA ,..•....a.g 15 2C17 ... Ar - - I= - FEET 4k;149PR.O.Fis.siOttl1/4\-f`. -106.4,16xc-`11- 1"=50' T15N R1W SEC8 LOT 113 DESIGN FACTORS: SYSTEM REQUIREMENTS: 600 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM PERK RATE: 10 MIN/IN 1250-GAL SEPTIC TANK APPLICATION RATE: 0.60 GPD/SF 600 GPD/ 0.6 GPD/SF / 5' WIDE * 0.5 REDUCTION= 100 LF TRENCH THEREFORE: CONSTRUCT TWO ABSORPTION TRENCHES 50' LONG x 5' WIDE x 4' EFFECTIVE DEPTH. FLOW LINE ELEVATION IN TRENCHES TO BE 2' BELOW ORIGINAL GROUND SURFACE. TOTAL DEPTH TO BE 6' BELOW EXISTING GROUND. PROVIDE 2" INSULATION AND 2' COVER OVER TRENCHES AND SEPTIC TANK, OR 3' COVER OVER ABSORPTION TRENCHES AND 4' COVER OVER SEPTIC TANK. 6" =111=I I = - I-1 I I=1 I I=1 I I-III-III-I I�I I I- - m_m= 1 I-T-Ei eI ia i 1=1 I H i=11, 1-I I-111-m-111-111-1 I ---1TTI-1 1'-6" 1�1-I�I=1�I=III-11 X11 X11 X11 X11 =LI= I-1Ti-111—I11=I 11=1 I�I I MI I EI I HI I HI 111=111-11 E11 F11 .11 H1 11=1 I r. _/_!_eft tyre. ...e. int! 6" :::.: 2" INSULATION ••••.'1 0 01'!'0.'!:•;•_A!! ti•=!�! ii 4" PERFORATED PVC (HOLES DOWN) :: :;::isi;::::::i;ii=::::::•:•:.:.:.:.:. DRAINFIELD ROCK :I:I�I�I:I�I�I�I:f:1:f:f:f:I�I�I�1�1�1�1�I:I�I:• :1:1:1:1:1:1:1:1:•.1:1:1:I:I�I�1�1�1�1�1�1�1:1:1 :1:1:1:.:1:1:1:1:1:1:1:1:1:1,I�I�I�I�I�1�1�1�1:• :1:1:1:1:1:1:1:1:1:1:Iaaa:•zI:•:1:1:1:1:1:1:1 5' 'I 4' TO GROUNDWATER 6' TO BEDROCK OR IMPERMEABLE LAYER 5' WIDE TRENCH SECTION PovF c :* • *-9.4- *17 ail AO TES: GROADE AREA OVER TRENCH TO DRAIN AWAY 0.4A , ��„ 1� MIN 6' SEPARATION FROM BEDROCK �/ BenSchiller MIN 4' SEPARATION FROM GROUNDWATER ootp;,... AELj 12592 ,F�� MIN 100' SEPARATION FROM NEARBY WELLS � F9F�PRO....HPC�4 MIN 100' SEPARATION FROM SURFACE WATER OR STREAMS A\Nkt���' MUNICIPALITY OF ANCHORAGE �,�NWItk DEVELOPMENT SERVICES DEPARTMENT i PC�!••' 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 j •,•, TH 4.--...;:1,�, SOILS LOG AND PERCOLATION TESTaftt 4 F . Benja/Schiller LEGAL DESCRIPTION: T 15N R I W SEC8 LOT 113 #4t;... A4. DM2 -- PERFORMED FOR: BRIAN COOK k PROFESSION DATE: 7-27-2017 PROJECT No.: ,\����� PARCEL ID#: TECHNICIAN: J. MILLETTE ProfessionolEn.ineersStam : DEPTH TEST HOLE 1 (feet) 1 SLOPE SITE PLAN 2 ,.• 4 - 5 ; - SILTY SAND SEE SITE PLAN 8 As: ,; - -1.Y-:::.4.--,..!.' WAS GROUND WATER ENCOUNTERED? NO 1 0 ':..• IF YES @ WHAT DEPTH') •' " DEPTH OF WATER AFTER MONITORING: NONE 1 1 "4- ' �"•, DATE OF MONITORING 8-4-17 GROSS TIME NET TIME DEPTH To fT DROP I DATE READING (MINUTES) (MINUTES) WATER N(INCHES) (INCHES) 14 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 7-27 1 7:20 0" 16 2 7:50 30 3.75" 3.75" 3 7:51 0" 17 4 8:21 30 3.50" 3.50" 18— 5 8:22 0" 19— 6 8:52 30 3.50" 3.50" 20 PERCOLATION RATE: 8.5 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4.0 FT. and 5.0 FT. COMMENTS: MUNICIPALITY OF ANCHORAGE _ _``\\\\l DEVELOPMENT SERVICES DEPARTMENT ��. :4��11� 4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 meg•• �1� ' 0*: 49TH )\ ...it y SOILS LOG - PERCOLATION TEST / ,, r„ .... Benja i� Schiller LEGAL DESCRIPTION: TISN RIW SECS LOT 113 70,1' •l,••C4092592 ...AO PERFORMED FOR: BRIAN COOK tlk\�;`SSS) DATE: 7-27-2017 PROJECT Na.: PARCEL ID#: TECHNICIAN: j. M ILLETTE Professional Engineers Stamp: DEPTII PERK TEST 2 (feet) OB/OG SLOPE SITE PLAN I 2 3 4 5 SEE SITE PLAN 9 6 7 8 9 WAS GROUND WATER ENCOUNTERED? 1 O IF YES @ WHAT DEPTH? DEPTH OF WATER AFTER MONITORING: 1 1 DATE OF MONITORING: 12 DATE READING GROSS TIME NET TIME WATER NET DROP 13 (MINUTES) (MINUTES) (INCHES) (INCHES) 14 7/27 TEST HOLE PRESOAKED PRIOR TO TESTING: 15 1 7:28 0:00 0" 16 2 7:58 30:00 3.25 3.25" 3 7:59 0:00 0" 17 4 8:29 30:00 3.00 3.0" 18 - 5 8:30 0:00 0" 19 6 9:00 30:00 3.00 3.0" 20 PERCOLATION RATE: 10.0 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES) TEST RUN BETWEEN: 4 FT. and 5 FT. COMMENTS: - MUNICIPALITY OF ANCHORAGE Community Development Department Phone: 907-343-7904 On -Site Water & Wastewater Program Fax: 907-343-7897 Areal estate property owner (Owner)may install their own septic The department may issue an approval for a homeowner to perform work on a conventional /not /\ on -ode wastewater disposal system hzserve that individual's ovwner-oocup/e/t single-family orduplex home /fthe homeowner satisfies and agrees tothe following requirements. The property owner and excavation equipment opera/orrnayperfonnw/orkonnonnorethan one owner installed project in a 12 -month period. - Aoowner nf(legal description) | agree the following items are true and accurate. 1-/5�J CA/ 1. My experience installing sepLi t is as follows. 2. The name of the excavation equipment operator is. 3. There will not be compensation for installation set -vices rendered. 4. | will be actively involved with the septic system installation at all times. 5. The name of the inspecting engineer is 7 ej-i dr\! r 8. | agree to discuss the following items with the inspecting engineer: a. Permit design criteria and specifications. b. Inspection requirements set forth in AMC 15.65.150. C. 2 -hour minimum advance notice given to the On-site Water & Wastewater Program for all required municipal inspections. 7. | agree any changes | make to the |terno listed above will require a new approval before performing work. 8. ! agree to have the project -specific On-site Wastewater Dispooa| System Permit available at the construction site for the duration of all related work. Owner's printed name: -7 �`�A, S Date: Owner's signature: Septic System Owner /nsta/er»mreem*nt-Feuco1m.uoc