ON-SITE WASTEWATER INSPECTION REPORT
Permit Number: OSP171220
PID Number. 051-151-19
ing: FIC Single Family (SF) ❑ Duplex (D) El Multiple (SF and/or D) Project: [E New ❑ Upgrade
Name:
Brian & Amanda Cook
ABSORPTION FIELD
0 Deep Trench 9 Shallow Trench El Bed ❑ Mound
Address
21464 Sunflower Lp, Chugiak, AK 99567
E] Other
Phone
Number of Bedrooms
Soil Rating
depth from original grade
351-4440
4
JTotal
0.6 GPD/SF
9.1 / 9.4 Ft.
LEGAL DESCRIPTION
Depth to pipe invert from original grade
5.1 /5.2 Ft.
Gravel depth beneath pipe
4.0 / 4.2 Ft.
Subdivision Block Lot
113
Fill added above original grade
1.0/1.0 Ft.
Gravel length
50 / 50 Ft.
Township Range Section
15N 1W 8
Gravel width
5.0 Ft.
Beds: Number of Lines
Distance between lines
Ft.
SEPARATION DISTANCES
Toj Septic i Absorption 1 Holding Sewer
'o'
Total absorption area
Number of trenches
Dist. between trenches
Lift Station
From I Tank Field Tank Line
2
1000 Ft
2
>10 Ft.
Well /
>1 oul! >10u, N/A NA >25'
TANK ®Septic F-1 S.T.E.P. 1771 Holding r_1 Other
Manufacturer
Anchorage Tank
Capacity
I 1250 Gal.
Surface Water >100' := >100' N/A N/A
Material Number of compartments
Steel 2
Lot Line >10' >10' N/A N/A
NA
F
Foundation >
o 10, >10, N/A N/A
LIFT STATION
Manufacturer
Capacity
Curtain Drain i None Noted
Gal.
Remarks
Pump on level at
in.
Pump off level at
in,
High water alarm at
in.
Pump make and model
Electrical Inspections performed by
to
PIPE MATERIAL House to tank D3034 Tankdrainfield D3034
Installer
Owner Install
Drainfield D3034 CO/MT D3034
Inspector J.Millette, B. Schiller
BENCH MARK (Assumed elevation) 100 ft
Inspdates:ection 1,,10/3/17 12/23/17
Location and description
2nd
3d 4th
Garage Slab
COMMUNITY DEVELOPMENT DEPARTMENT APPROVAL
Engineer's Stamp
0 F
Conditional Approval: Date
19,
*T
h
nenian �S&Jller
101
Approved fl /01/19
19592
11/7/18 .
ellI
..
- - .... t4;
Date
I
Inspection Report_9-1-12.doc
Tl 5N R1W SEC 8 LT113
PERMIT # OSP171220 PID # 051-151-19
x �
50' R.O.W!, RESERVE O
/ / r Lot 96 If t=Iv
ALTERNATE SIT
�fio. �:.: ` . 2S. �s, SO d
I
`sti , p •O c�
g I�
WELL
E
Lot 112 I"
.. .. ... ../........
. • Benjami chiller
�Fc •. CE 1 92 .••��i
Aor09.2018 .'_X\
A B C
FCO
17.1 6.0
SV1
51.9
41.3
SV2
61.5
48.0
2CO
65.5
50.4
C01
82.1
48.5
MT1
81.6
47.3
CO2
73.8
74.7
CO3
98.0
65.2
MT2
92.0
85.7
C04
90.1
85.4
JA
0 50 100
FEET
1 "=50'
1250 -'GAL -SEPTIC
TANK
/
2x 50' LONG xi5' WID , 4'
EFFECTIVE,DEPTH
ABSORPT16N TRENCHE
t
l
t
I
1
i
� t
T15N R1W SECS
LOT 113
50' R.O.W. RESERVE
LEGEND
CO - CLEANOUT
2CO - DOUBLE CLEANOUT
FCO - FOUNDATION CLEANOUT
FS - FLOW SPLITTER VALVE
MH - MANHOLE
MT - MONITORING TUBE
SV - SEPTIC VENT
TH - TEST HOLE
r
I—
0
m
N
fx
W
z
z
MUNICIPALITY OF ANCHORAGE
DEVELOPMENT SERVICES DEPARTMENT
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650
SOILS LOG AND PERCOLATION TEST
LEGAL DESCRIPTION: T 15N R I W SEC8 LOT 113
PERFORMED FOR: BRIAN COOK
DATE: 9-26-2017 PROJECT No.:
PARCEL ID#: 051-151-19 TECHNICIAN
DEPTH TEST HOLE 1 REV
(feet)
1 .,..
2
3
4
5 SILTY SAND
6
7
8
9
10
11 �•�"
12
14-
16-
17-
18-
19-
20
41617181920
COMMENTS
J. MILLETTE
SLOPE
WAS GROUND WATER ENCOUNTERED? NO
IF YES @ WHAT DEPTHI S
DEPTH OF WATER AFTER MONITORING: NONE L
DATE OF MONITORING: 10-3-17 liJ
E
SITE PLAN
SEE SITE PLAN
DATE
READING
GROSS TIME
(MINUTES)
NET TIME
(MINUTES)
DEPTH TO
WATER
(INCHES)
NET DROP
(INCHES)
TEST HOLE PRESOAKED PRIOR TO TESTING:
7-27
1
7:20
0"
2
7:50
30
3.75"
3.75"
3
7:51
0"
4
8:21
30
1 3.50"
3.50"
5
8:22
0"
6
8:52
30
3.50"
3.50"
PERCOLATION RATE: 8.5 (MIN/INCH) PERC. HOLE DIA. 6 —jINCHES)
TEST RUN BETWEEN: 4.0 FT. and 5.0 FT.
TEST HOLE DEEPEND TO 16' AND MONITORED FOR GROUND WATER
DUE TO CHANGED ELEVATIONS ON SEPTIC TANK AND TRENCH
OWNER OFLAND: Brian Cook
ADDRESS:
Bore Hole
Data
Depth
From
To
LEGAL DESCRIPTION T15NR1\NSEC OLOT II3
DATE: 9-28-17
PERMIT NUMBER: ospzrzzZO DATE OpISSUE: 8-15-17
TAX IDENTIFICATION NUMBER 05115119000
F7
|swell located atapproved permit location: i>(Yes| |No
��
Method of Drilling: �� ��airrotary L_|cab|etoo|
Depth of Well: 245'
[asingType: Steel Wall thickness .250 inches
Diameter: 6 inches, depth 245 feet
Liner type
Static Water Level: 79 feet
Recovery Rate 15 M Qpnn F] Qph
Method of Testing Air F7
Well Intake Opening Type: LXJopen end | |openho|e
F—) Screened Start feet Stopped
1-1
�Pe�orabons �1a� feet Stopped
Grout Type: Bentonite Volume: 50 lbs
Depth: from Z feet, to 42 feet
Well Disinfected Upon Completion: iXJyes Eno
Method of Disinfection: Chlorine 50 PPM
Comments:
4
51
51
90
90
155
155
160
160
179
179
185
185
221
221
239
239
245
Casing Stickup
Overburden
Silty Sand &Gravel
Tight Silty Sand &Gravel
Silt Gravel &[|ay
Silt & Sand Water
Clay &Gravel
Clay & Gravel Water
Clay
Clay 8'Gravel
Silty Sand &'Gravel Clean Water
Drillers Name: Cole Sullivan
ATTENTION: It is the responsibility of the property owner to submit a copy of the well log to the proper authority.
W1unidpe|hY of Anchorage: Department of Health & Human Services and/or Department of Environmental Conservation.
KAat3uBorough: Department ofEnvironmental Conservation.
Pump Installation Log
Well Drilling Permit Number: SW OSP171220 Date of Issue 8-15-17
Parcel Identification Number: 05115119000
Attention: The pump installer shall provide a pump installation log to the DSD within 30 days of pump installation.
�`"°""'� MUNICIPALITY HORA
4, ... oR 1.J
On-Site Water & WastewaterOFANCProgram
X11,
5
PO Box 196650 4700 Elmore Road f
Anchorage,Alaska 99519-6650 Phone:(907)343-7904 Fax:(907)343-7997
httpalwww.muni.orglonsite i
t.
I),•l,ai Inik•ni
,SCM ON''t
On-Site Water & Wastewater System Permit
Permit Number: OSP171220 Effective Date: 8/15/2017
Work Type: WellSeptic Initial Expiration Date: 8/15/2018
Tax Code Number: 05115119000
Site Legal Address: T15N R1W SEC 8 LT 113 G:1257
Site Mailing Address:
Owner: KROENER HILDA E Lot Size in Sq Ft: 108900
Design Engineer: ANDERSON ENGINEERING Total Bedrooms: 4
This permit is for the construction of:
0 Disposal Field Q Septic Tank El Holding Tank ❑ Privy Q Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: triaek Date: 5
Issued By: ;`ie('A Date: g1/71°r 7
MUNICIPALITY OF ANCHORAGE
Community Development DepartmentPhone: 907-343-7904
Development Services Division Fax: -1343-799Z
On-Site Water & Wastewater Program X45 \\
ti
ON-SITE SEWER/WELL PERMIT APPLICATION
AUG 0
Parcel I.D. 051-151-19 �6
Brian Cook 3514440 ,"
Property owner(s) Day phone y
Mailing address 16620 Brooks Lp, Eagle River, AK 99577
Site address NHN Old Cranberry Rd
Legal description (Sub'd., Block & Lot)
Legal description (Township, Range & Section) T15N R1 W SEC8 Lot 113
Lot Size 108,900 Sq. Ft. Number of Bedrooms Four
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(®all that apply)
Absorption Field El Initial 0 Single Family (SF) 0
(w/wo ADU)
Septic Tank 0 Upgrade ❑ Duplex (D) ❑
Holding Tank ❑ Renewal ❑ Multiple Dwellings ❑
Privy ❑ (SF and/or D)
Private Well 0
Water Storage ❑
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
/ z
(Si a ure of p operty owner or authorized agent)
Permit/Rush Fees: 60 t P1673 -leg Waiver Fees:
Date of Payment: gilt) L,(1 Date of Payment:
Receipt Number: QR I 1 t C Receipt Number:
Permit No. 05911 12-2-o Waiver No.
Permit App_9-1-12.doc
ANDERSON ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
August 9, 2017
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 Elmore Rd
Anchorage, AK 99519-6650
Subject: T15N R1 W SEC8 Lot 113
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of the Lot 113, at T15N R1W SEC8 intends to construct a new four-
bedroom home on the lot. We are therefore requesting a permit be issued for the
construction of a new well and septic system to accommodate the home. The attached
Site Plan and backup documentation identify the location and configuration of the
proposed well and septic system along with the alternate site. Also identified on the
plans are the existing wells in the area and septic systems on surrounding lots. No
conflicts exist between the proposed septic system and the existing septic systems and
wells on this and adjacent lots. Drainage arrows and ground surface contours are
shown on the site plan showing the grade and direction of flow on the lot. The drainage
pattern will not be changed as a result of this project.
The test hole placed on the lot in the area of the absorption trenches and alternate site
indicates silty sand. This test hole was perked, and a second perk test was performed
about 60' away. The soils were very hard, although the percolation rate was tested at
under 10 minutes per inch. No groundwater was found during the placement of the test
hole and none was found during the monitoring period. A conservative application rate
of 0.6 gallons per day per square foot was used in the design of the absorption system.
We are proposing to place a new 1 ,250-gallon septic tank and two 50' long by 5' wide
by 4' effective depth absorption trenches to treat and dispose of the effluent generated
in the house. The elevation of the distribution line in the absorption trench will be 2.0'
below the surface and the total depth will be 6.0'. A minimum of 2" of insulation and 2'
of fill will be placed over the absorption trench and septic tank.
The ground surface on the lot in the area of the septic system slopes to the northeast at
a shallow grade. The new trench will be constructed parallel to the ground contours in
conformance with Municipal requirements. The new septic system will be constructed a
minimum of 100' from all wells and any surface water and 10' the proposed and existing
water services in the area.
If the system is constructed in accordance with our design the following statements
apply:
1. The system, if constructed as designed, will have no adverse impact on the wells
in the area or those to be constructed in the future.
2. The system, if constructed as designed, will have no adverse impact on existing
septic systems in the area or those to be constructed in the future.
3. The system, if constructed as designed, will have no adverse impact on reserve
space, either surface or subsurface, on any lots located in the area.
4. The system, if constructed as designed, will have no adverse impact on drainage
patterns in the area. The current drainage pattern will be maintained.
���'samn
Sincerely, N, 0 A ,�leih
sse
PI
:*. 49TN to
Benjamin Schiller, P.E. ••• '4 """"
Attachments 'Baja f I '/
� "� 2 .*
_-- ,
I ;
. g/----
, .
I ,
_ .
I a
t•I \
\ i
0 PROPOSED WELL \ 'N. 2x 59 1_F SEPTIC TRE CH
6 ;IN \ 5' WIDE, 4' EFFECTIVE DEPTH
ZcIt-
-,.
-- --
I R • . . ;?...: •.• .. - -77 -+ - - - • -,),5-.., -0
erk Test 2
cc$
/ C •
CO 0 r‘ 1 ALTERNATE .-- ---- '
1 •.
2 % 1, SITE
.'N:. ' :-., 10 0 MT II
\ / •
t ‘ 1 k / 7)1\°
\ / SV 1 1 i k i
\ / SVIO, 1 t 1 ; t
t 1 ; t / /\•
/ .
t \fl ; t
N . / 2C0 riA-OL.3 LI / ,
Lot 1 1 2
4-13DRM H9ME
FC00
--.. -- 10.0 CA .:1..!INNTH#( _1
-_. _,
_--
LA ..._
co
v)
dx
100WELL RADIUS ILL.1
z
I--
z
M
\
1
T15N R1W SEC8 \
) LOT t13
[
100' WELL RADIUS \
N
--..
—,—
i
.'
---' ,/
—50' R.O.W. RESERVE ./
JAYHA1NK DRIVE
•Arkt• *.i'ii
0*:49111 .*
0; .... . ......„:.... .
OA. ,
ra . Ben in Schiller :
lifo.... AEL 12592 .• `4Al' 0 50 100
TA ,..•....a.g 15 2C17 ... Ar -
-
I= - FEET
4k;149PR.O.Fis.siOttl1/4\-f`.
-106.4,16xc-`11-
1"=50'
T15N R1W SEC8 LOT 113
DESIGN FACTORS: SYSTEM REQUIREMENTS:
600 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM
PERK RATE: 10 MIN/IN 1250-GAL SEPTIC TANK
APPLICATION RATE: 0.60 GPD/SF
600 GPD/ 0.6 GPD/SF / 5' WIDE * 0.5 REDUCTION= 100 LF TRENCH
THEREFORE: CONSTRUCT TWO ABSORPTION TRENCHES 50' LONG x 5' WIDE x 4' EFFECTIVE
DEPTH. FLOW LINE ELEVATION IN TRENCHES TO BE 2' BELOW ORIGINAL GROUND SURFACE.
TOTAL DEPTH TO BE 6' BELOW EXISTING GROUND. PROVIDE 2" INSULATION AND 2' COVER
OVER TRENCHES AND SEPTIC TANK, OR 3' COVER OVER ABSORPTION TRENCHES AND 4'
COVER OVER SEPTIC TANK.
6" =111=I I = -
I-1 I I=1 I I=1 I I-III-III-I I�I I I- -
m_m= 1 I-T-Ei eI ia i 1=1 I H i=11,
1-I I-111-m-111-111-1 I ---1TTI-1
1'-6" 1�1-I�I=1�I=III-11 X11 X11 X11 X11 =LI=
I-1Ti-111—I11=I 11=1 I�I I MI I EI I HI I HI
111=111-11 E11 F11 .11 H1 11=1 I
r. _/_!_eft tyre. ...e. int!
6" :::.:
2" INSULATION
••••.'1 0 01'!'0.'!:•;•_A!! ti•=!�! ii 4" PERFORATED PVC (HOLES DOWN)
:: :;::isi;::::::i;ii=::::::•:•:.:.:.:.:. DRAINFIELD ROCK
:I:I�I�I:I�I�I�I:f:1:f:f:f:I�I�I�1�1�1�1�I:I�I:•
:1:1:1:1:1:1:1:1:•.1:1:1:I:I�I�1�1�1�1�1�1�1:1:1
:1:1:1:.:1:1:1:1:1:1:1:1:1:1,I�I�I�I�I�1�1�1�1:•
:1:1:1:1:1:1:1:1:1:1:Iaaa:•zI:•:1:1:1:1:1:1:1
5' 'I
4' TO GROUNDWATER
6' TO BEDROCK OR IMPERMEABLE LAYER
5' WIDE TRENCH SECTION PovF c :* • *-9.4-
*17 ail
AO
TES:
GROADE AREA OVER TRENCH TO DRAIN AWAY
0.4A
, ��„ 1�
MIN 6' SEPARATION FROM BEDROCK �/ BenSchiller
MIN 4' SEPARATION FROM GROUNDWATER ootp;,... AELj 12592 ,F��
MIN 100' SEPARATION FROM NEARBY WELLS
� F9F�PRO....HPC�4
MIN 100' SEPARATION FROM SURFACE WATER OR STREAMS A\Nkt���'
MUNICIPALITY OF ANCHORAGE �,�NWItk
DEVELOPMENT SERVICES DEPARTMENT i PC�!••'
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 j •,•, TH 4.--...;:1,�,
SOILS LOG AND PERCOLATION TESTaftt
4 F .
Benja/Schiller
LEGAL DESCRIPTION: T 15N R I W SEC8 LOT 113 #4t;... A4. DM2 --
PERFORMED FOR: BRIAN COOK k PROFESSION
DATE: 7-27-2017 PROJECT No.: ,\�����
PARCEL ID#: TECHNICIAN: J. MILLETTE ProfessionolEn.ineersStam :
DEPTH TEST HOLE 1
(feet)
1 SLOPE SITE PLAN
2
,.•
4 -
5 ; - SILTY SAND SEE SITE PLAN
8 As:
,; -
-1.Y-:::.4.--,..!.' WAS GROUND WATER ENCOUNTERED? NO
1 0 ':..• IF YES @ WHAT DEPTH')
•' " DEPTH OF WATER AFTER MONITORING: NONE
1 1 "4- '
�"•, DATE OF MONITORING 8-4-17
GROSS TIME NET TIME DEPTH To fT DROP
I
DATE READING (MINUTES) (MINUTES) WATER N(INCHES)
(INCHES)
14 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 7-27 1 7:20 0"
16 2 7:50 30 3.75" 3.75"
3 7:51 0"
17 4 8:21 30 3.50"
3.50"
18— 5 8:22 0"
19— 6 8:52 30 3.50" 3.50"
20
PERCOLATION RATE: 8.5 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 4.0 FT. and 5.0 FT.
COMMENTS:
MUNICIPALITY OF ANCHORAGE _ _``\\\\l
DEVELOPMENT SERVICES DEPARTMENT ��. :4��11�
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 meg•• �1� '
0*: 49TH )\ ...it y
SOILS LOG - PERCOLATION TEST / ,, r„ ....
Benja i� Schiller
LEGAL DESCRIPTION: TISN RIW SECS LOT 113 70,1' •l,••C4092592 ...AO
PERFORMED FOR: BRIAN COOK tlk\�;`SSS)
DATE: 7-27-2017 PROJECT Na.:
PARCEL ID#: TECHNICIAN: j. M ILLETTE Professional Engineers Stamp:
DEPTII PERK TEST 2
(feet)
OB/OG SLOPE SITE PLAN
I
2
3
4
5 SEE SITE PLAN
9
6
7
8
9
WAS GROUND WATER ENCOUNTERED?
1 O
IF YES @ WHAT DEPTH?
DEPTH OF WATER AFTER MONITORING:
1 1 DATE OF MONITORING:
12
DATE READING GROSS TIME NET TIME WATER NET DROP
13 (MINUTES) (MINUTES) (INCHES) (INCHES)
14 7/27 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 1 7:28 0:00 0"
16 2 7:58 30:00 3.25 3.25"
3 7:59 0:00 0"
17 4 8:29 30:00 3.00 3.0"
18 - 5 8:30 0:00 0"
19 6 9:00 30:00 3.00 3.0"
20
PERCOLATION RATE: 10.0 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 4 FT. and 5 FT.
COMMENTS: -
MUNICIPALITY OF ANCHORAGE
Community Development Department Phone: 907-343-7904
On -Site Water & Wastewater Program Fax: 907-343-7897
Areal estate property owner (Owner)may install their own septic
The department may issue an approval for a homeowner to perform work on a conventional
/not /\ on -ode wastewater disposal system hzserve that individual's ovwner-oocup/e/t
single-family orduplex home /fthe homeowner satisfies and agrees tothe following
requirements.
The property owner and excavation equipment opera/orrnayperfonnw/orkonnonnorethan
one owner installed project in a 12 -month period.
-
Aoowner nf(legal description) | agree the
following items are true and accurate. 1-/5�J CA/
1. My experience installing sepLi t is as follows.
2. The name of the excavation equipment operator is.
3. There will not be compensation for installation set -vices rendered.
4. | will be actively involved with the septic system installation at all times.
5. The name of the inspecting engineer is 7 ej-i dr\! r
8. | agree to discuss the following items with the inspecting engineer:
a. Permit design criteria and specifications.
b. Inspection requirements set forth in AMC 15.65.150.
C. 2 -hour minimum advance notice given to the On-site Water & Wastewater
Program for all required municipal inspections.
7. | agree any changes | make to the |terno listed above will require a new approval before
performing work.
8. ! agree to have the project -specific On-site Wastewater Dispooa| System Permit available
at the construction site for the duration of all related work.
Owner's printed name:
-7 �`�A, S Date:
Owner's signature:
Septic System Owner /nsta/er»mreem*nt-Feuco1m.uoc