On-Site Water & Wastewater System Permit .
Permit Number: OSP171315 Effective Date: 10/18/2017
Work Type: WellSeptic Initial Expiration Date: 10/18/2018
Tax Code Number: 07832105000
Site Legal Address: THE CASCADES BLK 1 LT 5 G:0958
Site Mailing Address: 2630 WEST RIVER DR, Eagle River
Owner: SNS HOLDINGS LLC Lot Size in Sq Ft: 83493
Design Engineer: FORGE ENGINEERING Total Bedrooms: 3
This permit is for the construction of:
IE Disposal Field Il Septic Tank ❑ Holding Tank ❑ Privy IZI Private Well ❑ Water Storage
All construction shall be in accordance with:
1. The attached approved design.
2. All requirements specified in Anchorage Municipal code Chapters 15.55 and 15.65 and the State of Alaska
Wastewater Disposal Regulations (18AAC72) and Drinking Water Regulations (18AAC80)
3. The wastewater code requires inspections during the installation. The engineer shall notify the Development
Services Department per AMC 15.65. Provide notification by calling (907) 343-7904 (24/7).
4. From October 15 to April 15, a subsurface soil absorption system under construction during freezing weather
shall be either:
a. Opened and Closed on the same day, or
b. Covered, sealed, and heated to prevent freezing
Received By: 14 ,f/j'4;/ /2( : Date: s
Issued By: /4 IN / Date: �9
MUNICIPALITY OF ANCHORAGE
(TTba!
Community Development Department Phone: 907- 3 +'
Development Services Division — Fax 3 <I)On-Site Water & Wastewater Program ', I
r\r
ON-SITE SEWER/WELL PERMIT APPLICATION E OCT 1 0 2017 1'
ti
Parcel I.D. 078-321-05 zh`
Property owner(s) SNS Holdings Day phone 357 -'t3' - -
Mailing address 375 E. 76th Court Anchorage, AK 99518
Site address 2630 West River Drive Eagle River, AK 99577
Legal description (Sub'd.. Block & Lot) The Cascades, Block 1 , Lot 5
Legal description (Township, Range & Section)
Lot Size 83,493 Sq, Ft. Number of Bedrooms 3
APPLICATION IS FOR: APPLICATION IS AN: TYPE OF DWELLING:
(E7 all that apply)
Absorption Field (XI Initial ( I Single Family (SF) ❑
(w/wo ADU)
Septic Tank [X) Upgrade
Duplex (D) ❑
Holding Tank Renewal n
Multiple Dwellings ❑
Privy F I (SF and/or D)
Private Well X
Water Storage l
THIS APPLICATION INCLUDES A VARIANCE / WAIVER REQUEST FOR:
Distance:
I certify that the above information is correct. I further certify that this is in accordance with
applicable Municipal Codes.
(Signature of roperty owner or authorized agent)
Permit/Rush Fees: 3"Sct" Waiver Fees:
Date of Payment: 10/1( II .- Date of Payment:
Receipt Number: 0�t 0 710- Receipt Number
Permit No. 05P/713I5 Waiver No.
Permit App__-:•::..:C.
FORGE ENGINEERING
P.O. BOX 240773
ANCHORAGE, AK 99524
522-7773 677-7766 (FAX)
October 10, 2017
Municipality of Anchorage
Development Services Department
On-Site Water and Wastewater Program
4700 Elmore Rd
Anchorage, AK 99519-6650
Subject: Lot 5, Block 1, The Cascades Subdivision
Septic System Design and Permit Application
Impacts to Adjacent Properties
Dear Onsite Services Engineer:
The owner of Lot 5, Block 1, The Cascades Subdivision intends to construct a new three-
bedroom home on the property. We are therefore requesting a permit be issued for the
construction of a new well and septic system to accommodate the home. The attached Site Plan
and backup documentation identify the location and configuration of the proposed well and
septic system along with the alternate site. The surrounding lots with the exception of Lot 6 to
the north and Lot 3 (Block 2) to the east are currently vacant. No conflicts exist between the
proposed septic system and well or the proposed septic systems and wells on adjacent lots.
Drainage arrows are shown on the site plan showing the grade and direction of flow on the lot.
The drainage pattern will not be changed as a result of this project.
The test holes placed on the lot in the area of the absorption trench and alternate site indicate
sand with gravel (SW). The percolation rate of the soil was determined to be less than 1 minute
per inch. A mechanical analysis completed on the material indicated more than 50% of the
material was sand. No groundwater was found during the placement of the test holes and none
developed during the monitoring period. We are proposing to place a new 1,000-gallon septic
tank and a 45' long by 5' wide by 4' effective depth absorption trench. The elevation of the
distribution line in the absorption trench will be 3' below the surface and the total depth will be
7'. A minimum of 3' of fill or 2" of insulation and 2' of fill will be placed over the absorption
trench and 4' over the septic tank.
The ground surface on the lot in the area of the septic system slopes to the northeast at a grade
approaching 20% with some cross sloping from the east. The new trench will be constructed
parallel with the contours of the slope as much as possible in conformance with Municipal
requirements. The new septic system will be constructed a minimum of 100' from all wells and
any surface water and 10' the proposed and existing water services in the area.
If the system is constructed as designed, it will have no adverse impact:
• On the wells in the area or those to be constructed in the future.
• On existing septic systems in the area or those to be constructed in the future.
• On reserve space on any lots located in the area.
• On drainage patterns in the area. The current drainage pattern will be maintained.
Sincerely, t a� i�,� ♦_
or 'Tv
s x.'.•• .V
*/
4 T ; .
: o
1*
' M
Benjamin Schiller, P.E.
:mak in 1 0/r•Z
CE
Attachments
IllsSK ��Q.
I I 1
I
NO CONFLICTS WITH WELL OR I I
SEPTIC SYSTEM ON THIS LOT. NO SURFACE WATER NOTED
Lot 6 IN ROADSIDE DITCH I i
cPti
45'LONG X 5'WIDE X 4' ^. MEFFECTIVE DEPTH co (f)
ABSORPTION TRENCH �0 ,��;�`Al T.SITE .—i I
\` �••
•
\ ``` :Z7
•• TH1•' \\ �> C I— -
\ MT
PROPOSED 1000-GAL SEPTICco M
TANK M
zco I
Msv
gv a
e 73
TH2
•
IlC.
C
C
CID0
1\
I �\
1
vrn THE CASCADES
v LOT 5 \ 1'
VACANT
PROPOSED 1
WELL 4 1. 1 •
1:,,,
\
\ \ i
••
1
A i 1
1/• �1
f \
Lot 4 \
VACANT
CONTOUR INTERVALS:5'
�z�t\\\oNOTE:
�' OF AL t1 NO SLOPES>25%WITHIN 50'OR SURFACE WATER
P:
r •'' A1- t WITHIN 100'OF THE PROPOSED SEPTIC SYSTEM.
*: N ..*?, NO CONFLICTS WITH WELLS OR SEPTIC SYSTEMS
le r ON ADJACENT LOTS.
0 •. LEGEND
/ %• Benja n Schiller % 0 50 100 MT-MONITORING TUBE
`+ • AE 12592 • 'i FCC-FOUNDATION CLEANOUT
�1'�l'o•••O.....• #i im mi NI mi FEET
\ Ave.oassoos, 1°-50' TH-TEST HOLE
\x���� CO-CLEANOUT
THE CASCADES SUB, BLOCK 1 LOT 5
DESIGN FACTORS: SYSTEM REQUIREMENTS:
450 GPD PEAK FLOW 5' WIDE TRENCH SYSTEM
PERK RATE: <1 MIN/IN 1000-GAL SEPTIC TANK
APPLICATION RATE: 1.0 GPD/SF
450 GPD l 1.0 GPD/SF / 5' WIDE " 0.5 REDUCTION= 45 LF TRENCH
THEREFORE CONSTRUCT AN ABSORPTION TRENCH 45' LONG x 5' WIDE x 4' EFFECTIVE
DEPTH. FLOW LINE ELEVATION IN TRENCH TO BE 3' BELOW ORIGINAL GROUND SURFACE.
TOTAL DEPTH TO BE 7' BELOW EXISTING GROUND PROVIDE 3' COVER OR 2' COVER AND 2"
INSULATION OVER ABSORPTION TRENCHES AND 4' COVER OVER SEPTIC TANK.
1
6 — 1-11 ffI 11=1 —
IT_I=111=1I -11 -1I 1=111-111-�=111=111
I-111-111-111=111=111-11 El 1 El1Ell El
1 -111= 11=I=I=111=111=1 =11-111
1=111=11 ETI=111-11 -11Ell =1 I 1=11=1
2' 6" I I f-f-111-11 f-F1-111-11 l 1 I—ITI=1 I
X111-11 IA I I-111=111=111=11 =111—III=I 4" PERFORATED PVC (HOLES DOWN)
III-111—III 1 I X11 X11�11�11�1 11=
111111111111111 11 1E1 I 1/1111E111=__1111
111E1=11 =111=11 =111=1.11=111= =111=111=1
6
:fes•_•_/_/_/_/_/./../.••_f_f f• /./:.:+:+_._._*....,.
qt t t.rtrtrt:rt_.t�t t t _r DRAINFIELD ROCK
'� . . . • • • -r1.VtitteWetirtrtrlt • 1=1 • • •,
4 • f • •=t 1 t tr .:' t-rtr 11 1 f f ilili ,
'NIA; :e; a: or,
I,r�r�r_�r�r_�r:f:f:•:f:f:f:f:f:f:��/:I�1�1�1:11:1,
f�•�•�f:•fir:r:f:f:f:f:f:f:f:fJ IJ 1:I:I:�aaaaa.
4' TO GROUNDWATER
f:f:!#-•�f:f:1�f:f:f:f�I I�I�I 1�1 1 1 1 1 1 1 1,
6' TO BEDROCK OR
5' IMPERMEABLE LAYER
5' WIDE TRENCH SECTION -��F a _�gsll
(NO SCALE) ft ' •,�1y
NOTES: � 49TH * ,
fro
GRADE AREA OVER TRENCH TO DRAIN AWAY
MIN 6' SEPARATION FROM BEDROCK Be min Schiller j
MIN 4' SEPARATION FROM GROUNDWATER 1{9FG'••• EL 12592 le
MIN 100' SEPARATION FROM NEARBY WELLS ' `FOPROFES510 � "
MIN 100' SEPARATION FROM SURFACE WATER OR STREAMS vt����
MUNICIPALITY OF ANCHORAGE y���\\t`
;� ofAce: X114
DEVELOPMENT SERVICES DEPARTMENT ••• S
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650
ie'' ,91+
SOILS LOG AND PERCOLATION TEST . ,•
4 •
�� •a jamin Ie :,e
LEGAL DESCRIPTION: CASCADES, LOT 5 +w `�s�-•• ® •••. `�
PERFORMED FOR: FORGE ENGINEERING +'1\;\OFESSw +
DATE: 9-5-2017 PROJECT No.: I log 11
PARCEL ID#: 078-321-05 TECHNICIAN: J. M ILLETTE Profession:, I.r.`uioL n]t.cr.I
DEPTH TEST HOLE 1
(feet')
SLOPE SITE PLAN
5d '+.;.:tj?'k�7:
3 r:...,,. .?:,
Tft
5 SAND W/GRAVEL SEE SITE PLAN
r r ;; SW
6 .. :R;,-
7 �rJ . •.F
i s I..V
9 w:: !•: •
dux,. ,TA
ry t.4 w WAS GROUND WATER ENCOUNTERED? NO
1 O FSiyy .
P-1'.:::30,--ell' IF YES(a!WHAT DEPTH? , —
�
� DEPTH OF WATER AFTER MONITORING: M
11�' �<'•c, ;; DATE OF MONITORING: 9/25/17
s2 •'3s E
12 • a=� :
24. DEPTH To
•13 "' . s4• BOH DATE READING GROSS TIME NET TIME WATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
14 9/5 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 I 9:03 0
16 2 9:06 2:48 6 6
9 9:17 0
18 10 9:20 2:47 6 6
19 II 9:21 0
20- 12 9:23 2:47 6 6
PERCOLATION RATE:0.46 (MIN/INCII) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 3 FT. and 4 PT.
COMMENTS: PERK TEST WAS RUN 6 TIMES. INTERMEDIATE RESULTS ARE NOT SHOWN BUT WERE VERY SIMILAR.
MUNICIPALITY OF ANCHORAGE _���oF,\\�/`,
DEVELOPMENT SERVICES DEPARTMENT i�Pb! •�^I���,,
4700 ELMORE ROAD ANCHORAGE, AK 99519-6650 �*.STM �� *TA.
SOILS LOG AND PERCOLATION TEST ,"%c1:-.3,11_,.,...,
.�6 EienJaler •.
4
F;•, C
LEGAL DESCRIPTION: CASCADES, LOT 5 �Oh'.�j Fo®,.. ��
PERFORMED FOR: FORGE ENGINEERING 4 i PROFESSI4N��4
DATE: 9-5-2017 PROJECT No.: � 7
PARCEL ID#: 078-321-05 TECHNICIAN: J. MILLETTE Professional ` Stamp:
DEPTH TEST HOLE 2 ]
(feet)
1 r� SLOPE SITE PLAN
L .,:.tkirs,
m:'•3,
2 •,�w
3 '*`�. ,'•
5 �:3 SAND W/GRAVEL SEE SITE PLAN
ar Sw
6 C ,3
7 —Wi •''1;k.i
y,8 ,:Y , e
ro
9 —,.AdYjI:~zt
'4i herr,
10
Q—� f� �c4, WAS GROUND WATER ENCOUNTERED? No -
""'�'s IF YES @ WHAT DEPTII? —
0 �.' DEPTH OF WATER AFTER MONITORING OE
11 ,� . ,, DATE OF MONITORING: 9/25/17
12-,• 3•'.
;o*��:���. DEPTH TO
13 ''"' '' `' BOH DATE READING GROSS TIME NET TIME }NATER NET DROP
(MINUTES) (MINUTES) (INCHES) (INCHES)
14 9/5 TEST HOLE PRESOAKED PRIOR TO TESTING:
15 I 9:34 0
16 2 9:36 I I 6 6
•
17— 9 9:44 0
18— 10 9:46 I:`> . 6 6
19— II 9:47 0
20 12 9:49 1:54 6 6
PERCOLATION RATE:0.32 (MIN/INCH) PERC. HOLE DIA. 6 (INCHES)
TEST RUN BETWEEN: 3 FT. and 4 FT.
COMMENTS: PERK TEST WAS RUN 6 TIMES. INTERMEDIATE RESULTS ARE NOT SHOWN BUT WERE VERY SIMILAR.
. NORTHERN GEOTECHNICAL ENGINEERING, INC./ TERRA FIRMA TESTING
IhilL Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis
PROJECT CLIENT: Forge Engineering %GRAVEL 44.9 USCS SW-SM
PROJECT NAME: Cascade Lots %SAND 48.5 USACOE FC N/A
PROJECT NO.: 4813-17 %SILT/CLAY 6.6 %PASS.0.02 mm N/A
SAMPLE LOC.: TH 2 %MOIST.CONTENT 5.2 %PASS.0.002 mm N/A
NUMBER/DEPTH: UNIFORMITY COEFFICIENT(Cu) 27.7
DESCRIPTION: Well-graded sand v.1 sill and gravel COEFFICIENT OF GRADATION(Ce) _ 2.0
DATE RECEIVED: 9/5/2017 ASTM D1557(uncorrected) N/A
TESTED BY: CH ASTM D4718(corrected) N/A
REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A
PARTICLE SIZE ANALYSIS ASTM D422/C 136
us SW1.1041/41146 IS INCHES I II(GF VF NI VHF R, I IIYDROMFTFR SIEVE ANALYSIS RESULT
6 3 I.5 3/4 1123/6 1J uln .2n yn wa.1100 1200
100 1 3 I 14 4 I I I 1 )
. . -_._ I , ._.--. SIEVE SIEVE TOTAL% SPECIFICATION
90 I i' _SIZE(mm) SIZE(C S) PASSING (%PASSING)
� 1
80 , 152.40 6"
• — 76.20 3"
70
38.10 1.5" 100
n 60 - 19.00 3/4" 96
5 50 ,.. 12.70 1/2" 85
• 9.50 3/8" 76
m 40 --- 4.75 #4 55
z ♦ ji 2.00 #10 35
t ijj - .20 _ } Lt• -- Ili 0.85 #20 22
0.43 #40 15 _
• - ••• .:.. . . 0.25 #60 II
10 - --*— ♦ --- 0.15 #100 8
0 �� 1 0.075 #200 6.6
100 10 1 0.1 0.01 0.001
GRAIN SIZE(mm) HYDROMETER RESULT
GRAVEL SAND ELAPSED DIA"IETER TOTAL°/
(COBBLES II I I SILT or CLAY I TIME(MIN) (mm) PASSING
Coarse Fine Coarse Medium Fine 0
0.5
_ 1
MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2
4
145 8
-- 11 t 15
140 30
- _ ► I I- - 60
.' I35 L - , "
- --- 1440
t—t-- / r -r -1 I _
m 130 —� 1 A - - HYDRAULIC COND.
p N/A
> 125 •
(ASTM D2434)
p DEGRADATION N/A
I.'_i) I (ATM T-313)
I =__ - ! PLASTICITY INDEX NIA
I I - f—I--; I I t t ASTM 4318
0 2 4 6 8 10 12 14 16
MOISTURE CONTENT(%)
The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineering
interpretation or opinion be required,NGE-TFT will provide upon written request.
11301 Olive Lane - Anchorage,Alaska 99515 • Phone:907-344-5934 • Fax:907-344-5993 • www.nge-il.com
NORTHERN GEOTECHNICAL ENGINEERING, INC./ TERRA FIRMA TESTING
4 I 1 ' r-r--74.-
_ Laboratory Testing Geotechnical Engineering Instrumentation Construction Monitoring Services Thermal Analysis
PROJECT CLIENT: Forge Engineering %GRAVEL 47.5 USCS SW
PROJECT NAME: Cascade Lots %SAND 50.1 USACOE FC N/A
PROJECT NO.: 4813-17 %SILT/CLAY 2.4 %PASS.0.02 mm N/A
SAMPLE LOC.: TH 1 %MOIST.CONTENT 7.2 %PASS.0.002 mm N/A
NUMBER/DEPTH: UNIFORMITY COEFFICIENT(CO 14.2
DESCRIPTION: Well-graded sand ss/gra%el COEFFICIENT OF GRADATION(Ce) 1.1
DATE RECEIVED: 9/5/2017 ASTM D1557(uncorrected) N/A
TESTED BY: CH ASTM D4718(corrected) N/A
REVIEWED BY: RJPC OPTIMUM MOIST.CONTENT.(corrected) N/A
PARTICLE SIZE ANALYSIS ASTM D422/C 136
I:S SIEVE OPENING W nN[IIr3 I US SIEVE NUMBERS I IIYI)RIINITIR SIEVE ANALYSIS RESULT
6 5 1.5 Ne 1!21/8 A MIO 11211 rmu eN1 NM r?on
100 t 111111
1 I , / LL . I I . I SIEVE SIEVE TOTAL% SPECIFICATIU\
90 --1111-- it
i I SIZE(nun) SIZE(US) PASSING (%PASSING 1
80 ♦ 152.40 6"
70 ♦ I I 76.20 3"
.-- 38.10 1.5" 100
cf) 60 .i 19.00 314" 93
< 50 12.70 I'2" 79
9.50 3/8" 71
>-co 40 — i. 4.75 #4 53
a ♦ 2.00 #10 32
30 0.85 #20 17
ta' 20 0.43 #40 9
10
1 0.25 #60 5 _
♦ 0.15 #100 3
♦ • ♦ 1 — _r_ 0.075 #200 2.4
0
100 10 1 0.1 0.01 0.001
GRAIN SIZE(mm) FIYI)ROMETER RESULT
ELAPSED DIAMETER TOTAL%
COBBLES GRAVEL SAND
SILT or CLAY TIME(MIN) (mm) PASSING
Coarse Fine Coarse Medium Fine O
0.5
1
MOISTURE-DENSITY RELATIONSHIP ASTM D1557 2
4
145 _ � I 8
140 — I ;u
1—. 60
•. 1351 250
F T I 1440
z 130 —
•
•
HYDRAULIC COND.
125 i__�--_ (ASTM D2434) NIA
p _ • I ce
t DEGRADATION N/A
l } (ATM T-313)
120
- . — PLASTICITY INDEX
115
-- I i i I : i I I , , — ASTM 4318 N/A
0 2 4 6 8 10 12 14 16
MOISTURE CONTENT(%)
The testing services reported herein have been performed to recognized industry standards,unless otherwise noted. No other warranty is made. Should engineer-nip
interpretation or opinion be required,NGE-TFT will provide upon written request.
11301 Olive Lane Anchorage,Alaska 99515 • Phone:907-344-5934 • Fax: 907-344-5993 . www.nge-ffi.cor
O
•
Municipality of Anchorage
'� �
On-Site Water and Wastewater Program c,61897p �-' `
(907) 343-7904 rbv r F.., 4°. s a r r.r r
Certificate of On-Site Systems Ap
ti
Parcel I.D. 078-321-05 Expiratio � - ��w �ILAI 3, �?C l u
oI 6_9. 1--c
1. GENERAL INFORMATION
Complete legal description The Cascades Block 1 Lot 5
Location (site address) 2630 West River Dr
Current Property owner(s)
Troy Davis Homes Inc. Day phone 907-310-2501
Mailing address 1689 Knik Goose Bay Rd #400 Wasilla AK 99654
Real Estate Agent Day phone
2. TYPE OF DWELLING:
0 Single Family (w/wo ADU)
El Duplex
❑ Multiple Dwellings (Single Family and/or Duplex)
3. NUMBER OF BEDROOMS: 3
4. TYPE OF WATER SUPPLY: TYPE OF WASTEWATER DISPOSAL:
Individual Well 0 Individual El
Individual Water Storage ❑ Holding Tank ❑
Community Class Well ❑ Community ❑
Public Water System Cl Public Sewer ❑
WaiverNariance request for: Distance:
Received by: OAMbeia.) /21191i4 Date: xi/L-0
COSA to be released to the engineer,unless otherwise requested by the engineer.
COSA Fee $ I t -(P$ Waiver Fee $
Date of Payment 3 j2 3 i V" Date of Payment
Receipt Number •C)3-40 Receipt Number
COSA# dGI 1 < 164 Waiver#
5. STATEMENT OF INSPECTION BY ENGINEER
As certified by my seal affixed hereto and as of the validation date shown below, I verify that my investigation,
based on procedures outlined in the Certificate of On-Site Systems Approval Guidelines for this application,
shows that the on-site water supply and/or wastewater disposal system is (are) safe, functional and adequate
for the number of bedrooms and type of structure indicated herein. I further verify that based on the information
obtained from the Municipality of Anchorage files and from my investigation and inspection, the on-site water
supply and/or wastewater disposal system is(are) in compliance with all applicable Municipal and State codes,
ordinances, and regulations in effect at the time of installation.
Name of Firm Forge Engineering
Phone 907-522-7773
Address POBox 240773 Anchorage, AK 99524
Engineer's Printed Name Benjamin Schiller Date 3/21/18
4 of kk
�%q'7� {
6. iso i*:49 TM *��
SIGNATURE %
X System #1 Approved for 3 bedrooms "'
A
BenF in Schiller • f
System #2 Approved for bedrooms 0',• E•12 92 .•f4;Ail
Disapproved ��ki,s�:94j ../ ';c_':.
Conditional approval for bedrooms, with the following stipulatio'kV NNns:
..:(-- „. %
r•cc v
r
0 Nr1D 4-
•
'; - *s 9
'. PROG �,
�A44PNT e.
19 I vii. (). #
i ^.c1 Original Certificate Date: (.{ hc/ .201 '
•
The Municipality of Anchorage Development Services Division (DSD) issues Certificates of On-Site Systems Approval (COSA) based only
upon the representations given in paragraph 5 by an independent professional civil engineer registered in the State of Alaska. The Municipality
of Anchorage is not responsible for errors or omissions in the professional engineer's work.
7. ATTACHMENTS: •
COSA Checklist X ' _ i `-- . �,
Nitrate Advisory
Septic System Advisory y Arsenic Aksory/
Well Flow Advisory Other ' `,-' ' V• ' ,-,
COSA blue sheet r c
If more than 1 septic system is on the lot:
COSA Checklist# of
Structure served by this system
Certificate of On-Site Systems Approval Checklist
Legal Description:
The Cascades Block 1 Lot 5 Parcel ID: 078-321-05
A. WELL DATA Y
Private If A, B, or C provide PWSID# Well Log (YIN)
Well type Y
Date completed 10/24/17 Sanitary seal (Y/N) Y Wires properly protected (Y/N)
Casin hei ht above round) 24 in.
Total depth 43 ft. Cased to 43 ft. g g ( g
FROM WELL LOG AT INSPECTION
Date of test 10/24/17
Static water level
19 ft ft.
Well production 8 g.p.m. g.p.m.
WATER SAMPLE RESULTS:
Coliform absent colonies/100 mL Nitrate .1 OS mg/L
Wheaton Water Wells
Arsenic 1 • 1 ug/L Date of sample: �/ii/ I Collected by:
B. SEPTIC/HOLDING TANK DATA 11/14/17
Tank Type/Material Septic/Steel Date installed
Tank size 1000 gal. Number of Compartments 2 Cleanouts (Y/N) Y
Foundation cleanout(Y/N) Y Depression over tank (Y/N) N High water alarm (Y/N) N
Date of pumping
Pumper New Construction
C. ABSORPTION FIELD DATA
10/20/17S stem t e 5 Wide
Date installed Soil rating (g.p.d./ft2 or ftz/bdrm) 1 .0 y yp
Length 45 ft. Width 5.0
ft. Gravel below pipe 4.0 ft.
Total depth 9'6 ft. Eff. absorption area 450 ftZ Monitoring tube Y Depression over field N
Date of adequacy test
New Const Results(Pass/Fail) For bedrooms
Fluid depth in absorption field before test in. Water added gal. New depth in.
Elapsed Time: min. Final fluid depth in. Absorption rate >= g p d.
Any rejuvenation treatment(past 12 mo.) (Y/N &type)
If yes, give date
D. LIFT STATION
Date installed Size in gallons Manhole/Access (Y/N)
"Pump on" level at in. "Pump off' level at in. High water alarm level at
in.
Datum Cycles tested Meets alarm&circuit requirements?
E. SEPARATION DISTANCES
WELL ON LOT TO:
Septic tank/lift station on lot >100On adjacent lots >100'
Absorption field on lot >100' On adjacent lots >100'
Public sewer main >75' Public sewer manhole/cleanout >100'
Sewer/septic service line >25Holding tank >75'
Animal containment areas >50' Manure/animal excrete storage areas >100'
SEPTIC/HOLDING TANK ON LOT TO:
Building foundation >5' Property line >5' Absorption field >5'
Water main >10' Water service line >10' Surface water >100'
Wells on adjacent lots >100'
ABSORPTION FIELD ON LOT TO:
Property line >10Building foundation >�0� Water main >10'
Water Service line >10' Surface water >100' Driveway, parking/vehicle storage >10'
Curtain drain
None Noted Wells on adjacent lots > 00�
F. COMMENTS
G. ENGINEER'S CERTIFICATION .oza‘\��
:: °t yk
I certify that I have determined through field inspections and ,,�P.•'
review of Municipal records that the above systems are in ��R�:•• ����'••.
conformance with MOA COSA guidelines in effect on this date. f*• TH '.*t�I
Engineer's Printed Name Benjamin Schiller, PE
Date 3/21/18 / • Benja Schiller '
�i�� 4:,eReF:.*9.111.(%.,,,$;:r
COSA brown sheet_10-10-12.doc
33.2' -xk
i-3
HOUSE 60' N
DETAIL ,
2 STORY O
Scale: 1" = 20' A> RESIDENCE
cA N
N_ co
O
11
27.2'
6.1'x8.6' DECK
I I I Lot 6
/ II i
15' T&E EASEMENT— 1
I
) I
S 89)55'51'E 275.33
1
I
MOA STREAM LOCATION (1)
O
__ I ' cn
N
50' STREAM SEPTIC PIPES ni
Ls
/ / PR0TECTION
SETBACKS r.j
/
V)
// I
C 178/5'/ /
Z / /� 7 v� ��64.0 P1
I) m .•• j \
0 Z / / �G • I N \0
F:5
O I / O /�
v o / / I
� / 1 ��, II
�,
// J 100 pRorE�rry G�<�' 1 0
4.
/ I e �'A4!(1S �`�F o I
/ 01 // i-WELL �� '
/ / \ Lot 5
/ 1.917 Acres \
/ \
/ / \
--- \ \f 50 0
/ \/ \ \
/ i \
0�"� 3180 / \\
/ i 0 5g \ \
5
Lot 4 \ \\
\ \
PLOT PLAN AS BUILT X SCALE _1" = 50' GRID _ SW 958 _ Project No. 17-326/84
11500 Daryl Avenue, Anchorage, Alaska 99515-3049
Lang & Associates , inc . (907) 522-6476 Phone oop0
(907) 522-4625 Fax o�o F �/�0�4
Professional Land Surveyors kenOlangsurvey.com v ....:16.14
jonathanOlangsurvey.com 4 .• n
I herebycertifythat I have surveyed the followingdescribed property: Q��P. �)N 3 Ov
LOT 5. BLOCK 1, THE CASCADES SUBDIVISION (Plot No. 94128) �• 49TH•/\ . *QD
Anchorage Recording District, Alaska, and that the improvements situated thereon are 0
within the property lines and do not encroach onto the property adjacent thereto, that 0 0
no improvements on the properly lying adjacent thereto encroach on the surveyed 0 � KENNET' yI
premises and that there are no roadways. transmission lines or other visible VQ r`�, ' Cil easements on said property except as Indicated hereon. Q �' t8 Q
�4 P,' ..tS-520?.•'' cP,0
Dated this the i��l� Day of f--^►�lr.t,, _, .�"l`r� , at Anchorage, Alaskak‘`)4‘) ••.• Opo
pF.sSIONA+
it is the responsibility of the owner to determine the existence of any easements. �O�D000"'
covenants, or restrictions which do not appear on the recorded subdivision plat. AECC963